For an articulated-arm operator to open the gate to the desired angle and operate efficiently, it must be correctly anchored to the post. The manufacturer provides a precise chart showing the limits of use for each operator. The chart allows no margin for error, so if you choose A or B values outside the chart, the operator will not open the gate to the desired angle and will not work properly.

Example: NICE Wingo 2024 operator:

Mounting the rear fixing bracket:

Diagram of the NICE Wingo operator opening inward Diagram of the NICE Wingo operator opening outward
Inward opening diagram Outward opening diagram

Calculate the position of the rear bracket using the chart, from which you can read the dimensions A and B and the maximum opening angle. Note that the values A and B must be similar (ideally identical) to allow the operator to move smoothly in a linear motion.

NICE Wingo WG2024 operator installation chart Illustrative example of calculating the mounting dimensions for a NICE Wingo operator 
Calculation chart  Example of reading values from the chart 

Mounting charts for individual operators:

Wingo Toona Too

 

If the chart values for a standard articulated-arm operator do not work for your situation, you can: