Description of NICE Wingo WG4000 – standalone operator for swing gates with leaves up to 2 m / 400 kg
NICE WINGO WG4000 is a standalone electromechanical operator for one gate leaf at a private home. It has a 230 V AC / 50 Hz motor, a worm gear and a pre-installed mechanical opening stop. It is non-reversible; in the event of a power outage, it can be released with a key. Choose the control unit separately according to the number of motors and the gate equipment.
When to choose NICE WINGO WG4000
The operator is designed for residential swing gates. Before choosing, assess the length and weight of one gate leaf, its infill, wind exposure, hinge resistance and space for the brackets. The gate must move smoothly by hand along its entire travel and must not start moving on its own after stopping.
| Maximum leaf length | 2 m; the permitted weight varies according to the graph. |
|---|---|
| Maximum leaf weight | 400 kg for a shorter leaf, not necessarily at the maximum length. |
| Motor and control | 230 V AC motor, separate control unit; MC800 for one or two motors. |
| Use | Residential use, up to 30 cycles/hour at rated force and under suitable conditions. One cycle consists of opening and closing. |
The horizontal axis shows length in metres; the vertical axis shows weight in kilograms. Choose a combination within the grey area. At 2 m, the limit is approximately 200 kg; 400 kg applies to a leaf around 1 m long. Points A and B illustrate a suitable and an impermissible combination; they are not bracket mounting dimensions. A solid leaf and strong winds may further limit suitability.
What is included with the standalone operator
This product listing is for one WG4000 motor, not a complete two-leaf automation system. The motor comes with a front bracket, a rear bracket with mounting plate, fasteners, release keys and a pre-installed opening stop. Anchors for the specific post or wall must be selected to suit the substrate.
Choose the control unit, receiver, remotes, photocells and warning light separately or as part of a suitable kit. The gate must have a fixed closing stop. Two motors are required for a two-leaf gate.
Kits for one or two gate leaves
All kits listed include an MC800, an OXIBD receiver and one INTI2 remote. The basic kit does not include photocells; the photocell version adds a pair of EPM, while the accessories version also includes an ELAC. The number of motors matches the number of gate leaves.
| Gate | Kit |
|---|---|
| 1 leaf | Basic |
| 1 leaf | With accessories |
| 1 leaf | With photocells |
| 2 leaves | Basic |
| 2 leaves | With accessories |
| 2 leaves | With photocells |
Choosing a control unit
Current control unit NICE MC800 / MCA5R30 controls one or two 230 V motors and replaces older control units for these setups. For a single motor, an alternative is the NICE MC200 with its own wiring and functions.
Older compatible control units that have since been replaced: NICE Mindy A60, NICE A400, NICE-A6, NICE-A6F. If retaining them, follow the instructions for the board actually installed. Older MCA5 board and the newer MCA5R30 differ in their terminals and functions; the MC800 designation alone does not identify the generation.
The detailed steps below apply to MC800 with an MCA5R30 board and an OutSTB output. They are not instructions for setting up the A60, A6 or MC200.
I. Installing the rear bracket
Disconnect the power supply before starting work. The brackets must be securely anchored, and the motor must have room for its full range of movement, for the cover to open, and for manual release. The operator will not fix a gate that sticks or is incorrectly hung.
A operators, B photocells, C opening stops, D photocell posts, E warning light, F control device, G control unit. The specific safety devices should be selected based on the risks associated with the gate.
- Measure dimension C, i.e. the offset of the hinge axis from the mounting surface, as shown in the drawing.
- Find the measured value of C on the chart. The horizontal line gives dimension B; on the recommended mounting line r.i.l. / DIL read off the opening angle.
- From the selected point, draw a vertical line to axis A. A and B should be similar, ideally the same.
- If the angle is unsuitable, choose another permitted A/B combination. Do not adjust dimensions beyond the chart area.
- Before anchoring, check that the front bracket will sit on a solid part of the gate leaf and that the height difference between the brackets will be F = 30 mm.
Shorten the rear bracket to suit the required A/B dimensions and weld it to the mounting plate; then anchor the plate using suitable screws, washers and anchors. The supplied rear bracket is 150 mm. If the geometry requires a longer bracket, use the extended NICE PLA6 bracket; changing its length alone is no substitute for calculating the dimensions from the chart.
Complete dimensions of GAP02500 mounting brackets help confirm there is enough room for mounting. Check dimensions A/B/C against the hinge position and motor model.
Outward opening
WINGO can also be installed for outward opening, as shown in the following drawing. Allow for the extended rear bracket PLA6 and check the clearance outside the driveway. Adjust the motor wire directions to suit the wiring and check the correct leaf sequence again. Do not interchange the common wire and the protective PE conductor.
II. Front bracket and mounting dimensions
For the WG4000, D = 700 mm. Select dimension E according to A in the table. D is the installation dimension shown in the drawing; the actuator stroke is a different value. Weld the bracket to a solid part of the gate leaf; an alternative for bolting it on is NICE PLA8.
| A (mm) | E (mm) |
|---|---|
| 100 | 600 |
| 110 | 590 |
| 120 | 580 |
| 130 | 570 |
| 140 | 560 |
| 150 | 550 |
| 160 | 540 |
| 170 | 530 |
| 180 | 520 |
| 190 | 510 |
| 200 | 500 |
| 210 | 490 |
| 220 | 480 |
| 230 | 470 |
The front mounting point on the gate leaf is F = 30 mm lower than the rear mounting point on the post, as shown in the illustration. This does not mean the whole motor is tilted: check that it is correctly installed using a spirit level. Before welding, check both motor positions and make sure the bracket can reach the gate leaf.
III. Motor mounting
- Secure the motor to the rear bracket using the supplied bolt, washer and nut. Tighten the nut, then loosen it by approximately 1/10 of a turn, to leave the minimum clearance required.
- Attach the front section to the bracket using the supplied parts and tighten as shown in the diagram.
- Manually check the entire travel path, ensuring there is no binding or lateral strain. Attach the release procedure label near the drive unit.
IV. Mechanical stop adjustment
The pre-installed stop mechanically determines the open position; it is not an electrical limit switch. Ensure the gate has a firm stop when closed. The MC800 requires mechanical stops in both directions.
- Disconnect the power supply and release the motor.
- Loosen the mechanical stop screw.
- Manually open the gate leaf to the desired position.
- Slide the stop up to the pin and tighten the screw. Observe the dimension 90 mm max. shown in the stop adjustment detail. This dimension is not the motor's total stroke; for the WG4000, this is 320 mm.
- Manually close the gate leaf and engage the drive. Then carry out the setup procedure and test the complete system.
Manual release in the event of a power failure
- Stop the gate, disconnect the power supply and secure the gate leaf against unintended movement. If an electric lock is installed, unlock it first.
- Slide the lock cover aside, insert the key and turn it clockwise.
- Lift the release handle and guide its movement. You can now move the gate leaf manually.
- Before automatic operation, lower the handle, turn the key counterclockwise, remove it and close the protective cover. Check that the drive is engaged.
If the gate is the only entrance to the property, plan access to the release mechanism before installation. If a fault occurs, do not continue automatic operation until you have identified the cause.
Wiring
The following cable cross-sections and lengths apply to a system with an MC800/MCA5R30. Keep mains and motor cables separate from low-voltage signals, protect them from water and movement of the gate leaf, and secure them in cable glands. The power supply must have suitable overcurrent protection and a means of complete disconnection.
| Circuit | Cable | Length for MC800 |
|---|---|---|
| Power supply to control unit | 3 × 1.5 mm² | Up to 30 m; for longer runs, use 3 × 2.5 mm² and protective earthing at the automation system as specified in the manual. |
| Each 230 V motor | 4 × 1.5 mm² | Up to 10 m, including protective PE. |
| ELAC warning light | 2 × 1.5 mm² | Up to 20 m. |
| BlueBUS photocells | 2 × 0.5 mm² | Up to 20 m; for runs over 20 m and up to 40 m, use 2 × 1 mm²; no polarity. |
| Key switch | 2 cables, 2 × 0.5 mm² each | Up to 50 m. |
| Electric lock | 2 × 1 mm² | Up to 10 m. |
| Antenna | RG58 | Up to 20 m; less than 5 m is recommended. |
EPM relay photocells alone require both a power supply and a signal contact; the number of wires depends on the TX/RX wiring diagram and the selected testing mode. Complete MC800 wiring and installation.
Motor connection and accessory polarity
The WG4000 is a 230 V AC motor. Do not connect it to the 24 V motor output of the MC424L or MC824H. Connect the motor open / common / close wires and protective PE according to the markings on the motor and control unit. This is an AC circuit, not a +/− polarity connection. The motor has no separate encoder wire or volt-free electrical limit switches.
When using one motor with the MC800, use M2. When using two motors, M2 opens first and M1 closes first. To correct the direction, swap the two direction wires of the relevant motor; leave the common wire and PE on their designated terminals. Disconnect the power before making any wiring changes.
| 3 / 4 – auxiliary power supply | 3 = 0 V (−), 4 = Common +24 V DC (+), maximum total current 200 mA. |
|---|---|
| 5 / 3 – OutSTB | 5 = +24 V, 3 = −, switched photocell power supply, max. 4 W. It switches off in Standby; do not confuse it with the OGI terminal on older boards. |
| 6 / 7 – BlueBUS | Two-wire power and data; no +/− polarity. |
| FLASH | Self-flashing warning light 230 V AC, max. 21 W, for example, ELAC. Do not connect the low-voltage ELDC to this output. |
| 1 / 2 – ELS | Electric lock 12 V AC, max. 15 VA; no DC polarity. |
| 4 / 13 – SbS | Volt-free NO step-by-step contact; do not apply an external voltage to it. |
| 4 / 14, 4 / 15 | Volt-free NO contacts: open / close. |
| 4 / 12 – STOP | Learned safety input: NO, NC, or 8.2 kΩ, depending on the safety device wiring. |
| 8 / 9 / 10 – AUX | In relay photocell mode: PHOTO / PHOTO1 / PHOTO2, common contact 4; LP is lit. Input 11 is STOP in this mode. Unused AUX inputs should be left free; do not add universal jumpers. |
The board has buttons Open ▲, Stop/Set and Close ▼, LEDs L1–L8 and the AUX PRG. The receiver fits into the SM connector. Detailed wiring for each terminal.
Photocells, testing and safety edge
MC800/MCA5R30 supports both relay and BlueBUS photocells, including combined wiring. The AUX mode for relay photocells cannot be used together with AUX for electric limit switches; WINGO does not provide them on AUX. The TX/RX power supply wiring must match the Standby or photocell test mode.
The diagram shows combined wiring without photocell testing, Standby disabled. For a different mode, use its specific diagram; simply moving one jumper is not enough. For EPM with DC power supply, TX/RX 1 = +, 2 = −; RX 4 = COM, 5 = NC. The COM/NC contact connects between 4 Common and the selected PHOTO input 8, 9 or 10. Relay photocells, photocell testing and Standby.
Connect BlueBUS photocells in parallel using two non-polarized wires. The TX and RX units in each pair must have the same address; each pair must have a different address. After changing the wiring, run device recognition again. BlueBUS photocell addressing and responses.
Sensitive safety edges are required for an automation system with MC800. Select the type and position according to the potential trapping points and the test results. Photocells only protect the area they actually monitor. Connecting safety devices to STOP.
First startup with MC800 / MCA5R30
Before switching on, check that the unit is securely fastened, the release mechanism is locked, the stops and wiring are in place, the motor directions and M1/M2 order are correct, and all safety devices are connected. Keep the gate area clear during the first movement and be ready to stop it.
- After switching on, BlueBUS should flash about once per second; the LEDs on connected BlueBUS TX/RX units should flash, and FLASH should be off. If these conditions are not met, first correct the wiring fault.
- Device recognition: press and hold Open ▲ + Stop/Set and release when L1/L2 start flashing rapidly, after about 3 s. When successful, STOP lights up and L1/L2 go out. Run this procedure even if no accessories are installed.
- Automatic position learning: press and hold Stop/Set + Close ▼ and release when L3/L4 flash rapidly, after about 3 s. The sequence is: close M1, close M2, open M2, open M1, then close M1 and M2 to their respective stops. With one motor, only M2 operates.
- If the motor opens instead of closing first, interrupt the learning procedure by pressing Open or Close. Disconnect the power, correct the direction, and restart the learning procedure from the beginning. For a double-leaf gate with the leaves operating in the opposite order, correct the M1/M2 assignment. Leave a single motor connected to M2; if it runs in the wrong direction, swap only its direction wires.
- Successful position learning is confirmed when L3/L4 go out. If a photocell is triggered or STOP is activated, learning is interrupted; resolve the cause and repeat the entire procedure.
- Test repeated opening, closing and stopping, every safety device, leaf overlap and the release mechanism, and measure the forces of the complete system. Only hand over a gate for operation after it has passed all tests.
When testing the WINGO unit alone, it must be possible to move it manually with a force of no more than 390 N. This is the upper test limit, not a target for a stiff-moving gate or an impact-force setting. Assess forces during automatic operation using a separate measurement.
Settings and controls
The standalone motor has no programming buttons or radio receiver. Force, pause time, automatic closing, slow-down and leaf delay are set on the installed control unit. Repeat the tests after changing safety parameters. WINGO is electromechanical; do not enable pressure holding for hydraulic motors.
MC800 programming and tables · Manual and mixed position learning
When pairing a remote control, compatibility depends on the specific receiver and stored coding, not just the frequency. Current kits include OXIBD and INTI2. The bidirectional ON3EBD requires a compatible OXIBD; ON3ELR is for OXILR. Connect the external OXIBD antenna directly to the receiver as described in its instructions; do not automatically connect it to the control board antenna input shown in an older diagram.
Pairing and deleting remote controls
Troubleshooting checks
| Symptom | What to check |
|---|---|
| Motor does not move | Power supply, release mechanism locked, STOP and photocells. Check fuses and electrical circuits with the power switched off. |
| Motor runs, but the gate leaf does not move | Release mechanism locked, bracket connection and mechanical damage. |
| Gate leaf stops or reverses | First check manual movement, hinges, stops and obstructions; then check the photocells and safety settings. Do not increase the force without identifying the cause. |
| Incorrect direction or sequence | Direction wires and, with two motors, the M1/M2 assignment. Keep a single motor connected to M2; do not swap the common wire or PE. |
| Remote control does not respond, but the button does | Battery, compatibility, remote control pairing and receiver antenna. |
| Fault after replacing an accessory | Wiring, power supply, AUX or BlueBUS addresses, and repeat device recognition. |
Flash codes and repair procedures: MC800 diagnostics. Resetting the control unit, deleting the receiver memory and position learning are different procedures. Record the settings before resetting, and follow the instructions for your control board.
Compatible accessories
Choose accessories according to the actual control unit, its outputs and the installed receiver.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors, depending on the model selected. |
|
| Flashing light | Warns when the gate is moving. The voltage must match the control unit output. |
|
| Photocells | Monitor the selected area around the gate. MC800/MCA5R30 allows relay and BlueBUS photocells to be combined according to the wiring diagram. | |
| Transmitter | For remote control of the gate. | |
| Receiver | Choose the radio receiver according to the remotes’ coding. Smart control requires a specific compatible interface and power supply. |
|
| Antenna | Improves reception for a compatible receiver; follow its wiring instructions. | |
| Keypad | Gate control via a compatible receiver or decoding interface; the data device itself is not a direct NO contact. | |
| Key switch |
For key-operated gate control using a switch connected to the operator by cable from any location. |
|
| Card readers | Gate control via a compatible receiver or decoding interface; the data device itself is not a direct NO contact. |
|
| Electric locks | Additional gate-leaf locking, depending on the design and load; MC800 has an ELS output of 12 V AC / 15 VA. |
|
Estimated service life
Add the relevant weight and length indices, then factor in other influences. Use only one applicable row in each weight or length category. Use the total percentage to read the estimated number of cycles from the graph.
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Gate-leaf weight | over 100–200 kg → 10% over 200–300 kg → 20% over 300–400 kg → 30% |
|
| Gate-leaf length | 1–2 m → 20% | |
| Temperature / humidity | Above +40 °C or below 0 °C, or humidity above 80% → 20% | |
| Solid gate leaf | 15% | |
| Windy location | 15% |
The graph is an estimate based on regular maintenance; it does not guarantee a number of years or cycles. It cannot replace the graph showing the permissible gate-leaf weight and length. Assess operating loads and safety requirements for the entire gate.
Maintenance and safe use
At least every 6 months have the fasteners, brackets, hinges, wear, corrosion, screw lubrication, stops, release mechanism and wiring checked. After maintenance, test the gate movements and all safety devices again. For intensive use, set the maintenance interval according to operating conditions.
Do not touch the motor or gate leaf while it is moving, and enter only once it is fully open and has stopped. Children must not play near the gate or with the controls. If the gate has a pedestrian door, opening it must prevent the automation from starting. Regularly remove obstructions and clean the photocell windows. In the event of unusual noise, damage or unexpected movement, disconnect the power and arrange for repairs.
NICE WINGO WG4000 Technical Specifications
| Type | Irreversible electromechanical operator for one gate leaf, without a built-in control unit. |
|---|---|
| Motor power supply | 230 V AC / 50 Hz |
| Maximum / rated current | 1.5 A / 0.5 A |
| Maximum / rated power input | 200 W / 130 W |
| Stroke | 320 mm |
| No-load speed | 0.016 m/s |
| Maximum / rated force | 1,500 N / 500 N |
| Cycles per hour | 30 at rated force; the result depends on installation conditions. |
| Ingress protection rating | IP44 |
| Operating temperature | −20 to +50 °C |
| Insulation class | F |
| Dimensions | 770 × 98 × 95 mm (length × width × height) |
| Motor weight | 6 kg |
| Mechanical stop | Pre-installed opening stop; closing is handled by the fixed gate stop. |