Outdoor safety photocells NICE EPMB (Technical specifications) are installed opposite each other across the gate opening, or at any point where there is a risk of the gate hitting an obstacle. They create an infrared beam along the optical axis; when it is interrupted, they send a signal to stop the gate. They can only be used with devices that support NICE BlueBUS.

Installing NICE EPMB photocells

1. Open the photocell1a. Remove the transparent cover
1. Open the photocell 1a. Remove the transparent cover
2. Pull out the electronics as shown by the arrows3. Punch out the holes needed for installation
2. Pull out the electronics as shown by the arrows 3. Punch out the holes needed for installation
4. Punch out the required cable entry5. Refer to the example layouts, to determine how to position the photocells at the installation site.
4. Punch out the required cable entry
  • Check the drive control unit manual to confirm that it supports the required configuration.
  • Each pair of photocells in the installation must have its jumpers set differently.
  • Keep any unused jumpers for future use.
6. Based on the position of the photocells at the installation site, set the address jumpers according to the table.7. Position the photocells directly opposite each other
6. Set the address jumpers according to the table, based on the position of the photocells at the installation site. 7. Position the photocells directly opposite each other
8. Mount the photocell housings on a wall or post9. Connect the photocell wiring (make sure to disconnect the power supply first)
8. Mount the photocell housings on a wall or post 9. Connect the photocell wiring (make sure to disconnect the power supply first)
10. Fit the connected photocell electronics into the housings and restore the power supply. Run the connected-device detection phase on the drive control unit.11. Test the photocells. If you encounter a problem, follow the troubleshooting guide
10. Fit the connected photocell electronics into the housings and restore the power supply. Run the connected-device detection phase on the drive control unit. 11. Test the photocells. If you encounter a problem, follow the troubleshooting guide
12. Fit the cover onto the photocell and secure it with screws. Remember the insulating rubber gasket13. Fit the transparent cover. Remember the insulating rubber gasket. 
12. Fit the cover onto the photocell and secure it with screws. Remember the insulating rubber gasket 13. Fit the transparent cover. Remember the insulating rubber gasket.

 

Connecting multiple pairs of photocells NICE EPMB to the data network NICE BlueBUS

Position the photocells around the gate or door according to the example layouts for the complete wiring setup and set the jumpers according to the jumper table for the NICE EPMB gate drive. To prevent interference between pairs installed close to one another, the orientation of the transmitters and receivers must follow these example layouts, as shown in these example layouts TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):

Parallel wiring of NICE EPMB photocells for a gate drive

If you need the photocells to open the gate (see FA1 and FA2 in the example layouts), i.e. when a vehicle passes between their optical axes, triggering the gate to open, you need to interrupt connection A on both the transmitter TX and receiver RX, see illustration:

NICE EPMB photocell connection A

Examples of complete wiring configurations for multiple pairs of NICE photocells EPMB drive

1. Single-leaf sliding gate

Photocell wiring for a single-leaf sliding gate

2. Two synchronised sliding gates facing each other

Photocell wiring for two synchronised sliding gates facing each other

3. Swing gate

Photocell wiring for a swing gate

4. Sectional garage door

Photocell wiring for a sectional garage door

5. Up-and-over garage door

Photocell wiring for an up-and-over garage door

NICE photocell jumper table EPMB gate drive

6. Depending on the location of the photocells at the installation site, set the address jumpers according to the table.

Connecting multiple pairs of photocells to the system BlueBUS is done by setting different jumper combinations, with each connected pair requiring a unique jumper configuration. Make sure that no two pairs have the same configuration on a single BlueBUS data network. For each pair of photocells, set the jumper on both the transmitter (TX) and receiver (RX) to the same position. If the jumper configuration requires only one or no jumpers, keep any unused jumpers for future use.

Photocell pair designationJumper setting using a combination of jumpers
FOTO EPMB photocell jumper marked FOTO
FOTO II EPMB photocell jumper marked FOTO II
FOTO 1 EPMB photocell jumper marked FOTO 1
FOTO 1 II EPMB photocell jumper marked FOTO 1 II
FOTO 2 EPMB photocell jumper marked FOTO 2
FOTO 2 II EPMB photocell jumper marked FOTO 2 II
FOTO 3 EPMB photocell jumper marked FOTO 3

FA1
(Break connection A
on the TX transmitter
and the RX receiver)

EPMB photocell jumper marked FA1

FA2
(Break connection A
on the TX transmitter
and the RX receiver)

EPMB photocell jumper marked FA2

 

If a photocell needs to be replaced for any reason, simply set the same jumper as on the original one; there is no need to run the device recognition procedure.

Checking operation and troubleshooting NICE EPMB photocell wiring EPMB

10. Fit the connected photocell electronics into the photocell housings and switch on the power. Run the connected-device recognition procedure on the drive control unit.


After the drive has completed device recognition, check that the LED on both the TX transmitter and RX receiver is flashing. The LED may flash in the following ways:

 

LED "L"StatusWhat to do
Off The photocell is not receiving power or is faulty. Check that the voltage at the photocell inputs is approximately 8–12V. If the voltage is correct, the photocells are probably faulty.
3 quick flashes followed by a one-second pause The device has not been recognised by the drive control unit. Repeat the recognition procedure on the control unit. Make sure that each pair of photocells has a unique address assigned using jumpers .
Very slow flashing The TX transmitter is transmitting regularly
The RX receiver is receiving an excellent signal
Normal operation
Slow flashing The RX receiver is receiving a good signal Normal operation
Fast flashing The RX receiver is receiving a weak signal Normal operation. However, it is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean.
Very fast flashing The RX receiver is receiving a very weak signal Operation is still normal, but marginal. It is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean.
On The RX receiver is not receiving a signal Make sure the LED on the TX is flashing slowly. Check that there is no obstruction in the optical path between the TX transmitter and RX receiver. Check the alignment of the TX and RX.

 

NICE EPMB photocell technical specifications EPMB

Product type Detector for automatic swing gates, sliding gates and garage doors, Type D according to EN 12453, consisting of a transmitter TX and receiver RX.
Technology Direct optical TX-RX modulation with a modulated infrared beam.
Power supply/Output The device can only be connected to a data network that supports the NICE BlueBUS, from which it receives electrical power and sends an output signal.
Absorption 1 BlueBUS unit
Detection capability Opaque objects larger than 50 mm passing across the optical axis between the TX transmitter and RX receiver at speeds below 1.6 m/s.
TX transmitter angle 20° +-25%
RX receiver angle 8° +-25%
Normal range (usable) 15 m (may be halved in adverse weather conditions, e.g. fog, rain, dust, etc.)
Maximum range 30 m
Addressing 7 pairs with a safety function and 2 pairs with an "Open" command function
Use in acidic or saline environments, or in environments with an increased risk of explosion No
Installation Vertical wall mounting; maximum cable length for one branch of the BlueBUS system is 50 m.
Protection rating IP44
Operating temperature -20°C to 55°C
Dimensions (W×H×D) 50x80x28.5mm (one photocell)
Weight 143g (photocells combined)

 

Photocell wiring NICE EPMB with operator NICE Robus 400, 600, 1000

Wiring NICE EPMB photocells with NICE Robus 400, NICE Robus 600, NICE Robus operator

Inside the photocells NICE EPMB for gate operators

Photocells for NICE EPMB gate operator

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE EPMB - Era Photocell Medium - photocells with BlueBUS wiring (1 pair)

Product: NICE EPMB - Era Photocell Medium - photocells with BlueBUS wiring (1 pair)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.