NICE gate operators with the BlueBUS system

Technology BlueBUS allows multiple compatible devices to be connected using just a two-core cable, which carries both the power supply and the communication signal. The devices are connected in parallel, with no need to observe polarity, as each device is assigned a unique address.

Example of a parallel connection photocells supporting NICE BlueBUS

Parallel connection of NICE MOFB photocells for a gate opener

During the control unit's device assessment phase, all connected devices of the BlueBUS type are detected, and any deviations from the correct wiring are identified very precisely. For this reason, whenever another device is connected to the control unit, the device assessment phase must be carried out.

To the BlueBUS input, you can connect, for example: photocells, warning lights, safety devices, control buttons, etc.