NICE Robus RB600 - standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€437.07 including VAT
| Weight |
|---|
| 12 kg |
Description of NICE Robus RB600 - standalone operator for sliding gates (A)
The NICE RB600 drive has been replaced by a newer model NICE RBS600. See the advantages of the newer NICE RBS400 and RBS600 models.
NICE Robus RB600 gate opener is designed for sliding gates weighing up to 600 kg and a passage width of up to 8 m. It has an electromechanical limit switch. The gate opener is non-reversible. Detailed technical specifications ». Download the manual ».
(Is this gate opener right for me?)
Compare with other gate openers:
| « Lower-powered gate opener | Alternative gate opener | More powerful gate opener » |
|---|---|---|
|
|
![]()
|
|
This product—the standalone NICE Robus RB600 sliding gate opener (our code NICE-RB600-A)—includes:
- electromechanical NICE Robus RB600 gate opener with a capacity of 600 kg and a maximum gate leaf length of 8m, and a built-in (but removable) control unit RBA3R10 without radio receiver (OXI).
- 2 × release keys for manual operation of the gate opener (required in the event of a power failure)
- gate opener mounting components, anchors and bracket, gate opener limit switch stops
- installation manual
Discounted kits containing a gate opener NICE Robus RB600:
| Gate opener kit with accessories » | Gate opener kit with accessories and rack » |
|---|---|
|
Robus gate opener for gates up to 600 kg, remote control, photocells, flashing light, key switch. |
ROBUS gate opener for gates up to 600 kg, rack, remote control, photocells, flashing light, key switch. |
| Cantilever gate fabrication kit » | Track gate fabrication kit » |
Trolleys with 8 bearings, C-section 6+3m Fe, lead-in roller, end cap, guide, gate opener, rack. |
Ø100 mm wheels, 4x3m Zn track, end stops, guide, gate opener, rack. |
The gate opener is compact, safe and practical, and ideal for both residential and commercial use. Impact-resistant cover, aluminium-alloy body with an epoxy coating.
The gate opener is suitable for automating sliding gates weighing up to 600 kg, with a gate leaf length of up to 8 m. These values apply under the conditions specified by the manufacturer, including weather conditions, temperature variations, gate rigidity and, above all, smooth gate movement. These conditions cannot always be achieved or controlled, so we recommend using the NICE Robus RB600 gate opener ideally with gates operating at 80% of these limits. See the section Choosing a gate opener for more information.
Very user- friendly technology BlueBUS allows you to power and control up to 7 pairs of photocells using a two-core cable.
The temperature sensor adjusts the gate opener's pulling force according to climatic conditions. The gate opener also includes a thermal fuse.
Adjustable speed, force and pause time of the drive's automatic closing and many more, see Programming.
Diagnostics using warning light.
Gear wheel module 4 is compatible with the toothed rack in our range.
Robus 600 drive features "Slave unit" ensures automatic synchronisation of two motors. This means that two sliding gates moving towards each other can be automated.
The drive NICE Robus RB600 is an electromechanical drive suited to the climate in Slovakia and meets all European safety standards.
Accessories compatible with the NICE Robus RB600 drive
We also recommend purchasing compatible optional accessories for the drive, or choosing one of our pre-assembled discounted bundles:
| What | Why | Type |
|---|---|---|
| Warning light | The warning light flashes to signal gate movement—ideal for exits with limited visibility. It also has a built-in antenna for greater remote control range. | - LED warning light with antenna ELDC - multifunction light WLT - wireless solar LED warning light LLW |
| Photocells | They detect obstacles while the gate is closing and stop its movement, preventing it from hitting cars or people. | - Era Photocell Medium EPMB - Era Photocell Large EPLB - Era Photocell Slim EPSB - wireless FT210B - wireless EPMOW - solar-powered PHW |
| Transmitter | For remote gate control. | - Era One ON2E, ON3EBD, ON3ELR, ON4E, ON9E - Era Flor Flo2RE, Flo4RE - FloR Flo2R-s, Flo4R-s - Inti INTI2, INTI2Y, INTI2L, INTI2B, INTI2R, INTI2G |
| Receiver | Required for remote gate control. | - OXI - OXIBD - OXILR - Wi-Fi receiver IT4WIFI - GSM receiver GSM LITE3+, GSM SMART3, GSM PROFI3 |
| Antenna | For improved remote control range. | - built into the warning light ELDC - standalone antenna ABFKIT |
| Keypad | If you forget the remote control, or if lots of vehicles or people need access and you don't want to give everyone a remote or open the gate yourself. | - wireless EDSWG - wired EDSB |
| Key switch | Control the gate with a key using a switch connected to the operator by cable, which can be installed wherever you choose. | - surface-mounted, with standard cylinder EKS - surface-mounted, with European cylinder EKSEU - flush-mounted, with standard cylinder EKSI - flush-mounted, with European cylinder EKSIEU |
| Card readers | Control the operator by holding a card or key fob up to the card reader. | - ERA Transponder Reader ETPB |
| Gearing | Essential for the operator to automate the gate—without a rack, the operator has nothing to move the gate with. | - nylon, with steel reinforcement, 33 cm LZ-1 - nylon, with steel reinforcement, 1 m LZ-10 - nylon, with steel reinforcement, reverse profile, 1 m LZ-15 - steel, 30 x 8 mm, 1 m LZ-3 - steel, 30 x 12 mm, 1 m LZ-5 - stainless steel, 30 x 10 mm, 1 m LZ-7 |
| Backup power supply | Keeps the gate operating in the event of a power failure. | - backup battery PS124 - solar power supply SYKCE |
Manuals and documents for download
NICE Robus RB600 at a glance
NICE Robus is a family of irreversible electromechanical gear operators for sliding gates. They are supplied with a built-in (but removable) NICE RBA3R10 control unit with an SM connector for external receivers radio signal NICE SMXI, or NICE OXI. Electrical wiring of external devices (photocells, warning light, etc.) have been simplified in the NICE Robus sliding gate operator range by using BlueBUS, which allows several devices to be connected to a shared connector using just one two-core cable, with no need to observe polarity. Automatic operation depends on the power supply, but of course, in the event of a power failure, you can release the gear motor with the special release key and operate the gate manually. You can also purchase an optional NICE PS124 backup battery, which allows the gate operator to continue operating during a power failure.
Choosing an operator – is the NICE Robus RB600 suitable for my gate?
Every gate has its own size (and therefore leverage) and weight (and therefore the force exerted by its leverage) and every operator has its limits. The NICE Robus RB600 operator is suitable for the following gate leaf lengths and weights:
| Cycles per hour Consecutive cycles |
Gate leaf weight | ||||
| Up to 200 kg | 200–400 kg | 400–500 kg | 500–600 kg | ||
|---|---|---|---|---|---|
|
L |
Up to 4 m |
40 |
32 |
24 |
20 |
| 4–6 m | 25 13 |
20 16 |
15 9 |
13 6 |
|
| 6–8 m | 20 10 |
16 12 |
12 7 |
10 5 |
|
In principle gate leaf length determines the maximum number of cycles per hour and consecutive cycles, i.e. it indicates how long the operator can remain in operation. A higher weight further reduces the number of these cycles as a percentage, due to the increased load on the operator, and also determines the maximum permitted speed for the given load. The operator is equipped with a device (thermal fuse), which measures both the motor temperature and the ambient temperature, and reduces the number of possible cycles accordingly.
NICE Robus RB600 operator limits
The values shown are those recommended by NICE. Based on our experience, we recommend leaving a reserve of approx. 80% of the stated values:
| Maximum | Recommended | |
|---|---|---|
| Gate leaf length | 8 m | 6.5 m |
| Gate leaf weight | 600 kg | 500 kg |
Using the operator at maximum capacity reduces its service life — see the indicative calculation of the operator's service life in relation to stress factors:
NICE Robus RB600 operator service life
In the following table, add the stress indices for the weight and length of the gate leaf, then add the indices for other factors, if applicable. Then use the graph to find the operator's service life, expressed as the number of cycles.
Example: I have a gate with a passage width of 4.5 m and a structure and infill weighing up to 200 kg (a standard gate). I calculate the gate leaf length index as approx. 15 + gate weight index 10 +, to be on the safe side, I add a low-temperature index of 10 because our winters are harsher, giving me a total index of 35. The graph shows that the operator's service life is approximately 120,000 cycles. With 10 manoeuvres per day, this corresponds to a service life of approximately 32 years.
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Gate leaf weight |
The recommended maximum total index is up to 75%. (i.e. 40,000 cycles, which at normal use of 10 cycles/day amounts to 10 years)
|
|
| Up to 200 kg | 10 | |
| 200–400 kg | 30 | |
| 400–600 kg | 50 | |
| Gate leaf length | ||
| Up to 4 m | 10 | |
| 4–6 m | 20 | |
| 6–8 m | 35 | |
| Other factors (if the probability of occurrence is greater than 10%) | ||
| Ambient temperature above 40°C, below 0°C, or humidity above 80% | 10 | |
| Dusty environment | 15 | |
| Saline environment | 20 | |
| Photocell activation | 15 | |
| STOP input activation | 25 | |
| Speed higher than "L4 - Fast" | 20 | |
| Peak function active | 25 | |
Installing the NICE Robus RB600 operator
The installation method of the operator is different for track sliding gate and cantilever sliding gate different. For a track gate the operator is generally operator installed at ground level; for a cantilever gate it is necessary to operators raise them using, for example, threaded rods (Ø8 threaded rod), a custom-made bracket, a concrete plinth, etc. The decisive factor is the height of the rack, which should ideally mesh with the operator's pinion; see Rack and its end stop.
Wiring
Typical (optional) wiring layout for the operator and accessories:
List of accessories
|
|
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| A. Power supply | 3×1.5mm2 | 30m, for longer runs 3×2.5mm2 + earth |
| B. Warning light with antenna |
2×0.5mm2 |
20m 20m (recommended: less than 5m) |
| C. Photocells | 2×0.5mm2 | 30m, over 30m use 2×1mm2 |
| D. Key switch | 4×0.5mm2 | 50m (or 2 pcs. 2×0.5mm2) |
| E. Fixed safety edges | 2×0.5mm2 | 30m |
| F. Moving safety edges | 2×0.5mm2 | 30m |
Installation
See "What height should I install the drive at".
Gear rack and its stop
The gate moves when the drive's rotating pinion transfers torque into linear motion through the rack-and-pinion mechanism on the drive gear rack. The two most commonly used types of gear racks are:
|
Nylon gear rack (optionally with steel reinforcement) – attaches to the gate with self-tapping screws through the mounting tabs. Ideal for relatively light and short gates. Movement is quiet thanks to the friction between the steel pinion and the nylon rack. |
|
|
Steel gear rack – attaches to the gate by welding on threaded brackets, then screwing the rack into them. Used for longer and heavier gates. Movement is slightly noisier due to the friction of the steel pinion against the steel rack. |
It is essential that the drive pinion module is compatible with the gear rack module. The NICE Robus RB600 has a pinion module of 4.
The drive detects the open and closed end positions using end stops mounted on the gear rack:
Wiring the NICE Robus RB600 drive
Before connecting, disconnecting or changing the wiring of the drive, whether to the mains or to accessories, remember to disconnect the power supply at the circuit breaker, by removing the power fuse, or by disconnecting the backup battery.
...to the mains
![]() |
To get the drive working, you simply need to connect the drive power supply.
The wiring is simple:
|
...accessories
NICE RBA3R10 control unit of the NICE Robus RB600 provides the following inputs and outputs for accessories:
| Input/output | Description |
|---|---|
| Output for up to two 12V warning lights NICE LUCYB (or NICE MLBT) with one 12V 21W bulb | |
| S.C.A. (Indicator) |
Indicator output (24V 4W). Its operation can be set by Level II programming, parameter L4; see Level II programming, L4 – Output indicator. |
| Input for parallel connection of compatible devices using BlueBUS using a two-core cable that carries both the power supply and the communication signal. | |
| STOP (Stop) |
Input for devices that stop gate movement. The following devices can be connected:
|
| Input for devices that step through gate movement (see Step-by-step gate movement). Normally open devices (NO) can be connected. | |
| OPEN (Open) |
Input for devices that control gate opening (see Gate opening). Normally open devices (NO) can be connected. |
| CLOSE (Close) |
Input for devices that control gate opening (see Gate closing). Normally open devices (NO) can be connected. |
| AERIAL (Antenna) |
input for the radio receiver antenna. The antenna is usually built into the warning light, for example: NICE LUCYB, NICE MLBT, or a separate external antenna can be used NICE ABFKIT. |
Drive fuses
|
The drive contains two fuses:
|
||||||||||||
Standard wiring diagram:
Drive photocells
The highly user-friendly BlueBUS technology allows you to power and control up to 7 pairs of photocells using a two-core cable.
Connecting multiple pairs of photocells NICE EPMB to the data network NICE BlueBUS
Position the photocells around the gate, or gates, according to the example configurations for the complete wiring, and set the jumpers according to the jumper table for the NICE EPMB photocells gate drive. To prevent interference between pairs positioned close to one another, make sure to follow these example configurations, and observe the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you need the photocells to function as gate openers (see FA1 and FA2 in the example scenarios), i.e. when you drive a vehicle between their optical axes to open the gate, you need to interrupt connection A on the transmitter TX and receiver RX, see the figure:
Example photocell wiring scenario
NICE photocell jumper table EPMB gate operator
![]() |
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations, with each connected pair requiring a unique combination. Make sure that no two pairs in the same BlueBUS data network have the same combination. For each pair of photocells, set the same jumper configuration on both the TX transmitter and RX receiver. If a jumper configuration uses only one jumper, or none, keep any unused jumpers for future use. |
| Photocell pair designation | Jumper configuration |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
| FOTO 3 | ![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If a photocell needs to be replaced for any reason, simply set the same jumper configuration as on the original; there is no need to perform the device recognition procedure.
Radio receiver for gate operators
![]() |
NICE Robus RB600 gate operator is supplied with a NICE RBA3R10 control unit, which has an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted by remote controls, and is therefore required to operate the sliding gate remotely using a remote control. |
Selecting the gate’s direction of travel
The sliding gate’s direction of travel must be selected according to the position of the operator relative to the sliding gate leaf. View the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
The switch is located on the right-hand side of the RBA3R10 control unit in the centre.
Recognising connected gate operator devices
After connecting, disconnecting or changing the wiring of any accessories to the BlueBUS inputs and STOP the accessory recognition procedure must be performed.. The operator will indicate that this procedure needs to be performed by flashing LEDs L1 and L2.
![]() |
|
Measuring the gate leaf length
For the gate to move correctly (specifically, to calculate the acceleration and deceleration distances and partial opening), the operator must measure the length of the gate leaf. During this operation, the operator moves the gate from one end stop to the other and measures its length using a switch.
![]() |
|
Programming the operator
The Robus operator lets you program several functions, either by enabling or disabling a function using Level I programming, or by setting a default parameter using Level II programming..
RBA3R10 control unit has three buttons for operating and programming the operator:
![]() |
Button | Function |
|---|---|---|
| Open | The button instructs the operator to open the gate. During programming, it also moves the value of the parameter being programmed up. | |
| Stop/Set | The button instructs the operator to stop the gate. Pressing and holding it for 5 seconds the first time takes you to Level I programming. Pressing and holding it again takes you to Level II programming for the current LED. | |
| Close | The button instructs the operator to close the gate. During programming, it also moves the value of the parameter being programmed down. |
Level I programming
At Level I, programming enables/disables the selected function. When a function is enabled, its corresponding LED on the control unit is lit. All functions are disabled by default.
To enter Level I programming, press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Then use the “Open” and “Close” buttons to move the selected LED up or down. You have 10 seconds for each operation; otherwise, the operator exits programming mode. When the flashing LED is positioned above the LED for the function you want to enable or disable, press the “Stop/Set” button once to make it flash faster (function enabled) or slower (function disabled), then leave it as it is and let the operator exit programming mode within 10 seconds. If everything went as expected, the LED for the selected function will remain lit.
List of functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After a set period (configured under “Level II programming – Pause duration”), the gate will begin closing automatically after it has opened. If this function is disabled, the gate can only be operated with a command from a gate remote control or similar. |
| L2 | Close after photocell interruption |
This function keeps the gate open only for the time needed for a vehicle to pass through. Once the photocells are clear (the vehicle has passed through), the gate will start closing automatically after 5 seconds. This function operates in one of two ways, depending on whether automatic closing is enabled (see the previous function). Automatic closing enabled – the gate stops when the photocells are clear and starts closing after 5 seconds. This means it may not open all the way. |
| L3 | Always close | After a power failure, the gate either stays as it was (if this function is disabled) or closes (if the function is enabled). |
| L4 | Standby mode | This function reduces power consumption to a minimum. It is ideal for use with a backup battery supply (e.g. NICE PS124). If this function is enabled, the control unit switches off one minute after the gate's last movement. BlueBUS input (and therefore all devices connected to it), all LEDs except the BlueBUS LED, which will flash slowly. In this state, if a command is received, the control unit will restart first, and only then carry out the command. |
| L5 | Peak | Disables the drive's gradual start at the beginning of a movement and starts it at full force. Suitable where friction is high or the gate needs to break through snow and ice, so this function is especially useful in winter. On the other hand, it reduces the service life of the drive. |
| L6 | Pre-flashing | After receiving a command to move the gate, the warning light flashes for three seconds to warn the surrounding area, then the requested movement begins. |
| L7 | Close means Partial Opening | The command close will always start a partial gate opening movement. |
| L8 | Slave unit | Enabling this function is useful when installing two automated sliding gates facing each other — one drive is the master of the other. The slave drive has this function enabled and is synchronised with the master drive via the BlueBUS input. For more information, see Robus in slave mode. |
Level II programming
In Level II programming, values are set for the functions (these functions differ from those in Level I).).
Forget about Level I programming. To enter Level II programming, press and hold the “Stop/Set” button for about 5 seconds until LED L1. Then use the “Open” and “Close” buttons to move the currently selected LED up or down. You have 10 seconds for each operation; otherwise, the drive will exit programming mode. When the flashing LED is above the LED for the function whose parameter you want to set, press and hold “Stop/Set” to enter the settings for that LED. The LED that remains lit (while you continue holding “Stop/Set”) indicates the current parameter value. You can change this value up or down using the “Open” or “ "Close” buttons (while continuing to hold “Stop/Set”), then release “Stop/Set” and wait for the drive to exit programming mode within 10 seconds. To check that everything went as it should, repeat the procedure without changing the parameter value.
List of programmable functions and settings:
|
Input LED — Name |
Setting LED — Value |
|---|---|
| L1 — Pause time If the “Automatic closing” function is enabled in Level I programming, |
L1 — 5 seconds L2 — 15 seconds L3 — 30 seconds L4 — 45 seconds L5 — 60 seconds L6 — 80 seconds L7 — 120 seconds L8 — 180 seconds |
|
Sets the gate movement sequence triggered by repeatedly pressing, for example, a button on the gate remote control, or by activating the STEP-BY-STEP input (also referred to as P.P., or Step-by-step). |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium with two Stop commands L6 — Step-by-step with two commands, then partial opening L7 — Hold-to-run L8 — Semi-automatic opening, hold-to-run closing |
|
Sets the gate's speed during normal operation (excluding acceleration and deceleration). |
L1 — Very slow (30%) L2 — Slow (45%) L3 — Medium (55%) L4 — Fast (70%) L5 — Very fast (85%) L6 — Extremely fast (100%) L7 — Opens "Fast", closes "Slow" L8 — Opens "Extremely fast", closes "Fast" |
|
Sets when a signal should be sent to the of the S.C.A. output (24V -30% +50%, with a maximum power of 4W) |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
|
Indicates the gate's weight to the motor force control system This system also monitors the ambient temperature and automatically adjusts the motor force, for example, increasing it at very low temperatures. |
L1 — Ultra-light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Moderately heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Ultra-heavy gate |
|
Sets the travel distance for partial opening. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.5 m L8 — 4.0 m |
|
Sets the number of gate cycles after which the operator will indicate that maintenance is required. |
L1 — Automatic (the operator calculates this automatically based on the difficulty of the cycles) L2 — 1000 × L3 — 2000 × L4 — 4000 × L5 — 7000 × L6 — 10000 × L7 — 15000 × L8 — 20000 × |
|
Plays back the type of up to the last 8 error messages. |
L1 — Result of the 1st cycle L2 — Result of the 2nd cycle L3 — Result of the 3rd cycle L4 — Result of the 4th cycle L5 — Result of the 5th cycle L6 — Result of the 6th cycle L7 — Result of the 7th cycle L8 — Result of the 8th cycle |
Automating two opposing sliding gates with two NICE Robus RB600 operators
If you need to automate two sliding gates facing each other, operators can be connected in master-slave mode. The principle is that one operator is the master and sends commands to the other, the slave.. All Robus operators are set as master at the factory, so this parameter must be set on the slave operator in Level I programming. using function L8 — slave.
Limitations when connecting master and slave operators
- It is not possible to open the gate operated by the slave operator in any way other than fully (partial opening is not available). partial opening).
- All devices (photocells, receiver, etc.) must be connected to the master unit. Only the following may be connected to the slave unit: warning beacon, S.C.A. output indicator, devices connected to the STOP input and P.P. (also called STEP-BY-STEP, or Step-by-step), OPEN inputs and CLOSE are ignored.
- If you want to use a backup battery (NICE PS124), each drive must have its own.
- All programmed functions on the subordinate unit are ignored, except for functions programmed in:
| Level I programming. | Level II programming. |
|---|---|
| L4 - Standby mode | L3 - Motor speed |
| L5 - Peak | L4 - Output indicator |
| L8 - Subordinate unit | L5 - Motor force |
| L8 - Error log |
Installation procedure for two Robus drives in subordinate-unit mode
1. Install the gates and drives, and set the opening directions as follows:
2. Connect the drives as shown in the diagram (the polarity of the BlueBUS connection between the drives must be observed):
3. Run the power supply to both drives
4. On the subordinate unit, set the parameter in Level II programming L8 - Subordinate unit
5. Run the connected-device recognition phase on the subordinate unit
6. Run the connected-device recognition phase on the master unit
7. Run the gate leaf length recognition phase on the master unit
Connecting additional external devices to the drive
![]() |
If you need to connect additional devices to the drive that require an external power supply (e.g. indicator lights, key switch, magnetic cards, etc.), connect the device as shown in the diagram. The supplied voltage is 24 V DC, -30% to +50%, with a maximum current of 100 mA. |
Special drive functions
Gate held open
If a command to the STEP-BY-STEP input (also called P.P. or Step-by-step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is active. This function is useful when combined with a timer.
Forced operation
If a safety device fails, or, for example, an obstacle that cannot be removed gets into the beam of the photocells and the gate will not move for safety reasons, you can activate the “Hold-to-run” mode, either permanently in Level II programming by setting L2 - Step-by-step mode to L7 - Hold-to-run, or temporarily:
- Send a command to the gate using a (remote control, key switch etc.)
- If there is a problem, the gate will not move and the warning light will probably indicate an error.
- Therefore, within 3 seconds of the previous command, send the command again and hold it.
- The gate will move while you hold the command and stop when you release it.
Maintenance alert
In Level II programming under item L7 - Maintenance reminder you can set the number of cycles after which the drive should signal that maintenance (an inspection) is required. The drive signals this using the warning light (or the S.C.A. output, if configured in Level II programming under item L4 - Output indicator level L7 - Maintenance) as follows:
| Number of cycles | Warning light signal | Signal via the S.C.A. output indicator |
|---|---|---|
| less than 80% of the limit | Normal operation; flashes at half-second intervals. | “Lights up” for 2 seconds after opening begins. |
| 80–100% of the limit | Lights up for 2 seconds after the manoeuvre starts, then operates normally. | Flashes during the manoeuvre. |
| over 100% of the limit | Lights up for 2 seconds after the manoeuvre starts, then operates normally, and lights up for 2 seconds after the manoeuvre ends. | It keeps flashing. |
Instructions for clearing the maintenance warning and checking the current number of manoeuvres against the limit can be found in section 7.4.3 of the manual.
Troubleshooting the drive
If anything is unclear or you have any other problem, feel free to contact our technical support for NICE drives.
Depending on the nature of the problem
During installation (or if the drive malfunctions), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
The gate does not respond to the remote control, and the LED on the remote does not light up. |
Check whether the batteries drive remote control are working; if not, replace them. For instructions, see the manual for the specific remote control. |
|
The gate does not respond to the remote control, but the LED on the remote lights up. |
Check whether the remote control has been stored correctly in the memory of the receiver or try storing the remote control again. |
|
The gate does not move and the BlueBUS LED does not flash.
|
Check whether the drive is receiving 230V power. If it is, test both fuses and, if necessary, replace them with new ones of the same rating. |
|
The gate does not move and the warning light does not flash. |
Check whether the drive has registered the command. When a command is sent using the remote control the BlueBUS LED should flash twice quickly. If the command is sent by another device via the STEP-BY-STEP input (P.P.), the corresponding STEP-BY-STEP LED should light up.. |
|
The gate does not move and the warning light flashes several times. |
Count the flashes and see Diagnostics using warning-light flashes. |
|
The gate starts moving, then stops immediately and begins moving in the opposite direction. |
The programmed motor force is probably too low for your gate. Check that nothing is obstructing the gate, and if necessary increase the drive force or enable the Peak. |
|
The gate starts moving, but the warning light does not work. |
Check whether there is voltage at the FLASH output during gate operation (the voltage level does not matter; approx. 10-30Vdc). If there is voltage at the output, the problem is likely with the warning light, try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded; check whether the wiring has short-circuited. |
|
The gate starts moving, but the S.C.A. output does not work. |
Find out which function is programmed for the S.C.A. output and, if the output should flash, check whether there is voltage at the output (approximately 24Vdc). If there is voltage at the output, the problem is likely with the bulb; try replacing it with a similar one to see if it works. If there is no voltage at the output, the S.C.A. output may be overloaded; check whether the wiring has short-circuited. |
Diagnostics using warning-light flashes
While the gate is operating warning light flashes regularly once per second. If a problem occurs, the warning light signals an error with two consecutive series of faster flashes.
|
Flash sequence |
Error |
Solution |
|---|---|---|
|
1 flash 1-second pause 1 flash |
BlueBUS error
|
The devices connected to the BlueBUS input do not match those detected during the device detection phase. Run the detection phase again. If that does not help, try once more; otherwise, use a process of elimination to find the faulty device and replace it (purchase a replacement, make a warranty claim, or have it repaired). |
|
2 flashes 1-second pause 2 flashes |
Photocell activation |
The photocellsare being triggered, which is normal if their beam is interrupted while the gate is closing. If the beam was not interrupted, the photocells may be dirty, exposed to bright light, or faulty. |
|
3 flashes 1-second pause 3 flashes |
Motor force limiter activated
|
While moving, the gate detects increased friction—you may need to adjust the gate; try moving it manually and realigning it. Otherwise, the usual remedy is to increase the motor force, or enable the Peak function. Another possible problem is that your bottom stop is set too high. |
|
4 flashes 1-second pause 4 flashes |
STOP input activated
|
A command was sent to the STOP input, so if this was unexpected, check the devices connected to it. |
|
5 flashes 1-second pause 5 flashes |
Internal control unit error |
Wait 30 seconds and try again. If the problem persists, try resetting it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
6 flashes 1-second pause 6 flashes |
Hourly manoeuvre limit reached. |
Wait a few minutes for the cycle limiter to fall below the limit. |
|
7 flashes 1-second pause 7 flashes |
Internal electronic circuit fault. |
Disconnect the entire drive for a few seconds and try again. If the problem persists, try resetting it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
8 flashes 1-second pause 8 flashes |
Continuous command active.
|
A command is being continuously sent to the drive – check the devices connected to the OPEN input. If you have a timer connected, it is probably the cause.
|
Diagnostics using LED flashes
On the RBA3R10 control unit for the NICE Robus RB600 drive, there are two sets of LEDs. Each set uses flashing or steady lights to indicate normal operation of the control unit or to diagnose faults, as shown in the tables below.
Horizontal LEDs: BLUEBUS, STOP, PP, OPEN, CLOSE
|
Indicator |
Status |
Solution |
|---|---|---|
|
BlueBUS LED |
||
|
Off |
Fault
|
Check the mains connection; if it is OK, check fuses F1 and F2 and replace them, if necessary, with new fuses of the same type. |
|
On |
Serious fault
|
Try disconnecting the control unit, and if necessary, all inputs. If that does not help, reset the unit. If the problem persists, the control unit will probably need to be replaced. |
|
Flashing at one-second intervals |
Everything is OK |
Control unit operating normally. |
|
2 quick flashes |
Input status changed |
Normal operation – the status of the following inputs has changed: STEP-BY-STEP, STOP, OPEN, CLOSE; the photocells have been activated, or the drive received a command from a remote control. |
|
Series of flashes separated by a one-second pause |
Multiple possibilities |
The number of flashes in each series corresponds to the fault diagnosis indicated by the warning light. |
|
STOP LED (Stop) |
||
|
Off |
The STOP input has been activated |
Check the devices connected to the STOP input. |
|
On |
Everything is OK |
The STOP input is not active. |
|
STEP-BY-STEP LED (also labelled P.P., Step-by-step) |
||
|
Off |
Everything is OK |
STEP-BY-STEP input is not active. |
|
On |
The STEP-BY-STEP input has been activated |
Normal control unit operation if an active device is connected to the STEP-BY-STEP input. |
|
OPEN LED (Open) |
||
|
Off |
Everything is OK |
OPEN input is not active.
|
|
On |
The OPEN input has been activated |
Normal control unit operation if an active device is connected to the OPEN input. |
|
CLOSE LED (Close) |
||
|
Off |
Everything is OK |
CLOSE input is not active.
|
|
On |
The CLOSE input has been activated |
Normal control unit operation if an active device is connected to the CLOSE input. |
Vertical LEDs L1–L8
|
Indicator |
Solution |
|---|---|
|
LED 1 |
|
|
Off |
During normal operation, indicates that the Automatic closing function is disabled. |
|
On |
During normal operation, indicates that the Automatic closing function is enabled. |
|
Flashing |
|
|
LED 2 |
|
|
Off |
During normal operation, indicates that the function Close after photocell interruption is off. |
|
On |
During normal operation, indicates that the function Close after photocell interruption is on. |
|
Flashing |
|
|
LED 3 |
|
|
Off |
During normal operation, indicates that the function Always close is off. |
|
On |
During normal operation, indicates that the function Always close is on. |
|
Flashing |
|
|
LED 4 |
|
|
Off |
During normal operation, indicates that the Standby function is off. |
|
On |
During normal operation, indicates that the Standby function is on. |
|
Flashing |
|
|
LED 5 |
|
|
Off |
During normal operation, indicates that the function Peak is off. |
|
On |
During normal operation, indicates that the function Peak is on. |
|
Flashing |
The function is being programmed. |
|
LED 6 |
|
|
Off |
During normal operation, indicates that the function Pre-flashing is off. |
|
On |
During normal operation, indicates that the function Pre-flashing is on. |
|
Flashing |
The function is being programmed. |
|
LED 7 |
|
|
Off |
During normal operation, indicates that the function Close means Partial opening is off. |
|
On |
During normal operation, indicates that the function Close means Partial opening is on. |
|
Flashing |
The function is being programmed. |
|
LED 8 |
|
|
Off |
During normal operation, indicates that the function Slave unit is off. |
|
On |
During normal operation, indicates that the function Slave unit is on. |
|
Flashing |
The function is being programmed. |
Installing a backup battery for the NICE Robus 600 gate operator
NICE PS124 backup battery is not included as standard with the gate operator, but it can be ordered separately. It is used in the event of a power failure, when the gate operator will be powered by the battery. The battery is continuously charged from the mains.
| 1. Pry off the plastic cover from the battery connector | 2. Connect the battery to the connector and place it next to the control unit |
|---|---|
![]() |
![]() |
Manually releasing the NICE Robus RB600 gate operator
![]() |
In the event of a power failure, you will not be able to operate the gate using the remote control. Therefore, the gate operator can be released using the release key so you can move the gate manually: |
| 1. Slide the release lock cover aside | 2. Insert the release key and turn it clockwise |
|---|---|
![]() |
![]() |
| 3. Pull out the release lever | 4. You can move the gate manually |
![]() |
![]() |
Technical specifications of the NICE Robus RB600 gate operator
| Model | NICE Robus RB600 |
|---|---|
| Model description | Electromechanical gear motor for the automatic operation of sliding gates in residential settings. Supplied with NICE RBA3R10 control unit, but without radio receiver. |
| Sprocket | Number of teeth: 15 Tooth module: 4 Pitch: 12,6mm Pitch diameter: 60mm |
| Torque [Force] |
18Nm [600N] - required to start the gate |
| Rated torque [Rated force] |
9Nm [300N] - required to keep the gate moving |
| Speed | 0,31 m/s |
| Rated speed | 0,15 m/s |
| Limit on consecutive cycles | 100 cycles/day (the control unit limits the number based on the restrictions; see Choosing a drive) |
| Operating time limit | 7 minutes (the control unit limits the time based on the restrictions; see Choosing a drive) |
| Service life | from 250,000 to 20,000 cycles, depending on the weight and length of the gate leaf, as well as the drive settings |
| Power supply | 230V (+10% -15%) 50/60Hz |
|
Power consumption |
515W [2,5A] |
| Insulation class | 1 - must be earthed |
| Backup power supply | can be purchased separately and installed NICE PS124 backup battery |
| Warning light output | for two warning lights 12V with a 21W bulb (e.g. NICE Lucy LUCYB, NICE Moonlight MLBT) |
| Indicator output (S.C.A.) | for one 21V bulb, max. 4W (output voltage +50% -30%); can control a small relay |
| BlueBUS output | one output for up to 15 BlueBUS devices |
| STOP input | for normally open, normally closed and 8.2KΩ constant-resistance devices |
| STEP-BY-STEP input (P.P., step-by-step operation) | normally open (closing the contact triggers the “Step-by-step") |
| OPEN input | normally open (closing the contact triggers the “Open") |
| CLOSE input | normally open (closing the contact triggers the “Close") |
| Radio receiver | without a receiver; “SM” connector for receivers NICE SMXI, NICE OXI etc. |
| Antenna input | 52Ω for RG-58 coaxial cable (or similar) |
| Programming functions | 8 on/off functions (Level I programming.) 8 adjustable functions (Level II programming.) |
| Self-learning functions |
gate leaf length detection (calculates acceleration and deceleration distances and the partial-opening position) |
| Operating temperature | -20°C to +50°C |
| Use in saline, acidic and potentially explosive environments | no |
| Protection rating | IP44 |
| Dimensions | 210×330×303 (W×L×H) |
| Weight | 11kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]