NICE ROBUS RBS600 - standalone drive for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€480.82 including VAT
| Weight |
|---|
| 11 kg |
Description of NICE ROBUS RBS600 - standalone drive for sliding gates (A)
Operator NICE Robus RBS600 is designed for sliding gates with a weight of up to 600 kg and a clear opening width of up to 8 m. It has an inductive limit switch. The operator is non-reversible. The operator is compact, safe and practical, with an impact-resistant cover, and is ideal for residential and commercial use. Detailed technical specifications ». Programming the operator ». Download the manual ».
This product—the standalone NICE Robus RBS600 sliding gate operator (our code NICE-RBS600-A)—includes:
- Electromechanical NICE Robus RBS600 operator with a capacity of 600 kg and a maximum gate leaf length of 8 m, with a built-in (but removable) MCU1R30 control unit, with a built-in radio receiver and an “SM” connector for a plug-in receiver.
- 2 x release keys for manual operation of the operator (required in the event of a power failure).
- Operator mounting components : anchors, mounting plate and magnetic stops for the inductive limit switch.
- Installation manual
One of the main advantages of the Robus RBS600 is its high opening and closing speed, made possible by advanced technology. It features obstacle detection and the option to connect photocells, ensuring maximum safety. It is also equipped with a temperature sensor that adjusts the operator's pulling force to the climatic conditions, and is protected by a thermal fuse.
The high-quality construction and IP44 protection rating ensure the operator's long service life. Robus RBS600 is compatible with Nice accessories. The integrated "Eye Check" system provides visual feedback via an LED light (red/green).
The “Slave Unit” function (master-slave mode) allows two motors to be controlled in sync, making it possible to automate two sliding gate leaves moving in opposite directions. It is also compatible with the older Robus RB600, but only versions equipped with the RBA3R10 control unit. The older RBA3/c is not compatible with RBS.
The built-in control unit makes operation simple. Programmability is one of this model's key features.
The built-in bidirectional receiver is ready for immediate programming, making it easy to connect and control.
Another advantage is the option to add extra functions via an expansion board, including lighting for a safer installation.
User-friendly BlueBUS technology makes it easy to power and control up to 7 pairs of photocells using a two-core cable.
The operator achieves up to 90% energy savings in standby mode and is compatible with the Nice solar kit.
It is fitted with a module 4, compatible with the toothed rack in our range.
Thanks to the BiDi-WiFi module (optional accessory), the operator can be controlled using the mobile MyNice app (Android/iOS) and programmed with MyNice Pro (Android/iOS).
Remote control compatibility:
The operator has a built-in receiver and is compatible with NICE series MYGO, ONE and INTI remote controls. The internal receiver does not support FloR or Flo coding. However, the control unit also has an SM connector for connecting a plug-in receiver, which may be useful if you have replaced an old operator with the new RBS and own older-model remote controls.
Information for owners of older NICE FLOR remote controls:
If you already own older NICE FLOR remote controls (models FLO2R-S, FLO2RE, FLO4R-S, FLO4RE), you can continue using them with the new NICE RBS. However, you will need to purchase a plug-in OXIBD receiver or one of the external receivers, such as NICE OX2.
Extra-long range for remote controls:
The operator NICE RBS has a slot for an internal receiver, allowing you to install a NICE OXILR receiver with LoRa. You can also connect a NICE OXIFM receiver for expanded functionality.
Information for owners of legacy NICE FLO and NICE SMILO remote controls:
If you use NICE remote controls at home with FLO or SMILO, these can also be used with the NICE RBS. However, you must purchase an internal receiver OXIBD, which supports receiving fixed-code signals (FLO, SMILO). In this case, the receiver will accept only these older types of remote controls, and newer models cannot be paired at the same time.
Accessories compatible with the Nice Robus RBS600 operator
We recommend purchasing compatible optional accessories for the operator or choosing one of our pre-assembled operator bundles at a special price.
| What | Why | Type |
|---|---|---|
| Warning light | Flashes to indicate gate movement – ideal for exits with limited visibility. Also includes an antenna for increased remote-control range. |
Alternatively, all warning lights with 12V–24V power supply from other manufacturers. |
| Photocells | They detect obstacles as the gate closes and stop its movement – preventing the gate from hitting cars or people. | |
| Transmitter | For remote gate operation. | |
| Receiver |
For remote gate operation. The RBS operator has an integrated radio receiver, but it also allows you to connect a plug-in receiver. This makes it easy to switch from an older RB operator to a newer RBS without pairing the remote controls again. |
|
| Programming devices |
|
|
| Antenna | For increased remote-control range. | |
| Keypad | If you forget your remote control, or have many vehicles or users and don’t want to issue a remote control to everyone. | |
| Key switch | Operate the gate with a key using a switch wired to the operator. | |
| Card readers | Operate the operator by presenting a card or key fob to the reader. | ERA Transponder Reader ETPB |
| Drive rack | Required for automation – without a rack, the operator cannot move the gate. | |
| Backup power supply | Keeps the gate operating during a power outage. |
Manuals and documents to download
Nice Robus RBS600 drive manual – PDF
Instructions for pairing remotes with a Nice drive – link
NICE Robus RBS600 at a glance
NICE Robus RBS is a range irreversible electromechanical gear drives for sliding gates. They are supplied with a built-in (removable) NICE MCU1R30 control unit with a built-in receiver and an SM connector for plug-in receivers using OXI radio signals, for example NICE OXIBD. It features an ON-OFF function for disabling the internal receiver (in Level I programming). The internal receiver does not support FloR or Flo coding.
Electrical connections for external devices ( photocells, warning beacon etc.) have been simplified in the NICE Robus RBS range with BlueBUS, which allows several devices to be connected to a shared connector using a single two-core cable (with no need to observe polarity). Conventional relay-operated photocells can also be connected to the control unit.. The MCU1R30 control unit also has an OSE input (Optoelectronic Safety Edge), max. 15 mA.
Automatic operation of the drive depends on the availability of electrical power. In the event of a power outage, the motor can be released using the release key. You can also purchase the NICE PSS124 backup battery, which allows operation during a power outage. The older backup power supply NICE PS124 is compatible only when used with the CABLA11 adapter.
The drive has two LEDs: green indicates movement, while red indicates active photocells, abnormal conditions and faults. The limit switch is inductive.. The drive can also be operated and its functions configured using the mobile My Nice Pro app (Android/iOS).
Choosing a drive – is the NICE Robus RBS600 drive suitable for my gate?
Every gate has its own size (i.e. leverage) and weight (i.e. the force exerted by its weight), and every drive has its limits.. The NICE Robus RBS600 drive is suitable for gates with the following leaf lengths and weights:
| Cycles per hour Consecutive cycles |
Gate leaf weight | ||
|---|---|---|---|
| up to 400 kg | up to 600 kg | ||
| Gate leaf length | up to 4 m | 35 | 40 |
| from 8 m | 20 | 20 | |
In general, the gate leaf length determines the maximum number of cycles per hour and of consecutive cycles, i.e. it indicates how long the drive can operate.. Greater weight reduces these figures proportionally because of the increased load, and also determines the maximum permitted speed for that load. The drive is equipped with a thermal fuse that measures the temperature of the motor and its surroundings and reduces the number of possible cycles accordingly.
The values shown apply when the manufacturer's conditions are met (weather conditions, temperatures, rigidity and smooth movement of the gate). In practice, we recommend keeping the total load to approximately 80% of these parameters.
NICE Robus RBS600 drive limits
The values shown are recommended by NICE. Based on our experience, we recommend leaving a margin of approx. 20% below the values shown:
| Robus RBS600 | Maximum | Recommended |
|---|---|---|
| Gate leaf length | 8 m | 6 m |
| Gate leaf weight | 600 kg | 480 kg |
Using the drive at its maximum capacity reduces its service life – below is an estimated service-life calculation based on stress factors.
NICE Robus RBS600 drive service life
In the table, add the stress indices for the gate leaf's weight and length, then add the indices for any other applicable factors. Then use the graph to estimate the drive's service life in cycles.
Example: A gate with a 4.5 m clear opening and weighing up to 200 kg: length index ~30 + weight index 10 + low-temperature index 10 ⇒ total 40. The graph indicates ~120,000 cycles, which is ≈ 32 years at 10 operations per day.
Installing the NICE Robus RBS600 drive
The installation method for the drive is different for a track sliding gate and a cantilever sliding gate . For a track gate the drive is generally installed at ground level, while for a cantilever gate the drive needs to be raised (M8 threaded rods, custom bracket, raised concrete base, etc.). The key is the height of the rack, so that it meshes ideally with the drive gear (see “Rack and its limit stop”).
Wiring
A typical (optional) drive and accessories wiring setup looks as follows:
Accessories list
- A – Nice Robus RBS drive
- B – Photocells
- C – Photocell posts
- D – Key switch
- E – Flashing light with built-in antenna
- F – Rack
- G – Static safety edge 1
- H – Moving safety edge 1
- I – Opening limit stop
- J – Static safety edge 2
- K – Moving safety edge 2
- L – Closing limit stop
- M – Remote control
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| Power supply | 3 × 1.5 mm² |
30 m For longer distances, use 3 × 2.5 mm² + earth. |
| Flashing light with antenna |
2 × 0.5 mm² 1 × RG58 coaxial cable |
20 m 10 m (recommended < 5 m) |
| Photocells | 2 × 0.5 mm² |
30 m; use 2 × 1 mm² for lengths over 30 m
Ifthe BlueBUS cable is > 30 m (max. 50 m), use 2 × 1 mm². |
| Key switch | 2 cables, each 2 × 0.5 mm² |
50 m
Can be replaced with one 4 × 0.5 mm² cable. |
| Safety edges – static | 2 × 0.5 mm² |
30 m
For multiple static edges, see the manual – “Adding or removing devices / STOP input”. |
| Safety edges – moving | 2 × 0.5 mm² |
50 m
For multiple static edges, see the manual – “Adding or removing devices / STOP input”. |
Installation
One of the requirements for correct operation is the installation height of the drive. Read more in the article “What height should the drive be installed at?”.
Rack and its limit stop
Operating principle: the rotary torque of the drive gear is converted into linear motion via the rack-and-pinion drive on the rack. The most common types:
| Nylon rack (optionally with a steel core) – secured with self-tapping screws through the mounting holes; ideal for lighter/shorter gates, with quieter operation (nylon vs. steel gear). | |
| Steel rack – secured by welding on threaded brackets and then bolting the rack in place; suitable for longer/heavier gates, with slightly noisier operation (steel vs. steel). |
It is essential, that the drive gear module is compatible with the module of the rack. The NICE Robus RBS600 has a module of 4.
The drive detects the open and closed end positions using limit stops mounted on the rack.
Procedure for installing the limit stops on the rack:
1. Align the drive and gate. The gate and drive must be level.
2. Leave a 1–2 mm gap between the rack and gear so that the weight of the gate is not transferred to the motor.
3. Tighten the drive mounting so it does not shift when engaged.
4. Move the gate to the open position and adjust the stops so they activate the switch at the end position.
5. Move the gate to the closed position and adjust the limit stops so that they activate the switch at the end position.
Wiring the NICE Robus RBS600 operator
Before connecting, disconnecting, or changing the operator wiring (to the mains or to accessories), remember to disconnect the power supply — switch off the circuit breakers, remove the power fuse, or disconnect the backup battery.
WIRING to the mains
|
For basic operation, you need to run a operator power supply cable. |
| The wiring is simple: | |
| L — live (brown) | |
| I — earth/PE (green) | |
| N — neutral (blue) |
WIRING accessories
NICE MCU1R30 control unit operator NICE Robus RBS600 provides the following inputs and outputs:
| Input/output | Description |
|---|---|
| FLASH (warning light) |
24 V output for a warning light, e.g. Nice ELDC. |
| OGI (indicator) |
Output for an indicator (24 V). Behavior configurable in Level II programming, item L4 — Indicator output. |
| FOTO (photocells) |
Photocell input. |
| STEP-BY-STEP (SbS, P.P., step-by-step control) |
Input for devices that step through the gate's movement. NO (normally open) contacts can be connected. |
| 24 V (+) | Power supply for external devices (e.g. contactless card reader): 24 V DC, −30% to +50%, max. current 100 mA. |
| GND (ground) |
Ground for external devices powered from the 24 V terminal. |
| STOP (stop) |
Input for devices that stop the gate's movement. Possible configurations:
|
| OSE (optical safety edge) |
Interface for an OSE (Optical Safety Edge) sensor, 12 V. |
| BLUEBUS | Input for parallel connection of compatible devices using BlueBUS (the two-wire cable provides both power and communication). |
| AERIAL (antenna) |
Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. Nice ELDC, or an external NICE Aerial ABF. |
Operator fuses
The operator contains two fuses:
| Designation | Protected circuit | Type |
|---|---|---|
| F1 | control unit | T 2A 250 V |
| F2 | power supply | T 1.6A 250 V |
|
||
Standard wiring diagram
Operator photocells
User-friendly BlueBUS technology allows you to power and control up to 7 pairs of photocells using a two-wire cable.
Connecting multiple pairs of NICE EPMB photocells to the NICE BlueBUS data network
Position the photocells around the gate according to the example configurations for complete wiring, and set the jumpers according to the photocell jumper table for the NICE EPMB photocells. To prevent interference between pairs positioned close together, observe the orientation of the transmitters TX and receivers RX as shown in the example configurations. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you want the photocells to function as gate openers (see FA1 and FA2 in the example configurations), i.e. trigger opening when a vehicle passes between their optical axes, disconnect connection A on both the transmitter TX and receiver RX — see figure:
Example photocell wiring configuration
NICE EPMB photocell jumper table
![]() |
Connecting multiple pairs of photocells to the system BlueBUS is done by setting different jumper combinations. Each connected pair must have a unique combination; two pairs with the same setting must not be used on a single BlueBUS data network. Set the jumper identically on the TX transmitter and RX receiver within each pair. Keep unused jumpers for future use. |
| Photocell pair designation | Jumper — jumper combination |
|---|---|
| PHOTO | ![]() |
| PHOTO II | ![]() |
| PHOTO 1 | ![]() |
| PHOTO 1 II | ![]() |
| PHOTO 2 | ![]() |
| PHOTO 2 II | ![]() |
| PHOTO 3 | ![]() |
| FA1 (Break the connection A on both TX and RX) |
![]() |
| FA2 (Break the connection A on both TX and RX) |
![]() |
If you need to replace a photocell, set the same jumper on it as on the original; there is no need to repeat the device detection procedure.
Radio receiver for operators
NICE Robus RBS600 operator has a built-in radio receiver in the control unit NICE MCU1R30. The MCU1R30 also has an SM connector (under the plastic cover) for connecting an external radio receiver NICE OXIBD (or the older NICE OXI). The SM connector makes it easy to upgrade from an older Robus RB operator to a Robus RBS while retaining the paired remote controls.
Selecting the gate direction of travel
The direction selected must match the position of the operator relative to the gate leaf. View the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
| The switch is on the rear side of the control unit, on the right. |
|
Detection of connected operator devices
Whenever you connect, disconnect or change the wiring of devices connected to the BlueBUS and STOP inputs, perform the accessory detection procedure. The operator indicates that this is required by flashing LEDs L1 and L2.
![]() |
|
Detecting the gate-leaf length
For the operator to calculate the acceleration/deceleration distance and partial opening correctly, it operator must detect the length of the gate leaf. During the procedure, it moves the gate from one end stop to the other and detects the length using a switch.
Programming the operator
The Robus RBS operator allows you to program various functions, either by enabling or disabling a function in Level I programming or by setting a preset parameter in Level II programming.
MCU1R30 control unit has three buttons for operating and programming the operator:
Programming – Level I
In Level I programming, you enable or disable the function. When a function is enabled, its corresponding LED on the control unit lights up. All functions are disabled by default.
Entering Level I programming Press and hold the “Stop/Set” button for approximately 5 seconds, until LED L1. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each action; otherwise, the operator exits programming mode. When the flashing LED is next to the function you want to change, press “Stop/Set” to make the flashing faster (function enabled) or slower (function disabled), then allow the operator to exit the mode within 20 seconds. If everything has worked correctly, the corresponding LED will remain lit.
List of functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After the set time (“Level II Programming – Pause Duration”), the gate closes automatically after opening. If this function is disabled, the gate responds only to a command (e.g. from a remote control or similar). |
| L2 | Close after photocells are interrupted | Once the photocells are clear (the vehicle has passed), closing starts after 5 seconds. Behaviour depends on L1:
|
| L3 | Always close | After a power outage, the gate either stays in its original position (disabled) or closes automatically (enabled). |
| L4 | Standby mode | Reduces power consumption to a minimum (useful with PSS124). One minute after the last movement, BlueBUS (and connected devices) and all LEDs except the BlueBUS LED switch off (the BlueBUS LED flashes slowly). When a command is received, the control unit first wakes up/restarts and only then carries out the command. |
| L5 | Starting acceleration | Disables soft starting—the motor immediately runs at full power (useful in conditions with high friction, snow or ice). Reduces the service life of the drive. |
| L6 | Pre-flashing | Before the gate starts moving, the warning light flashes for 3 seconds before the manoeuvre starts. |
| L7 | Disable the built-in radio control | Disables the radio receiver integrated into the control unit. Enable this if you use an external plug-in receiver such as the OXI. If this function is disabled, the built-in receiver remains active. |
| L8 | “Slave” mode – subordinate unit | When activated, the drive becomes the “Slave”. Allows two motors on opposing gate leaves to be synchronised (Master/Slave). For details, see the Robus RBS manual, section “Slave mode”. |
Programming – Level II
Level II is used to set function values (different from those in Level I).
Entering Level II programming Press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each operation; otherwise, the drive exits the mode. When the LED is next to the function whose parameter you want to adjust, press and hold “Stop/Set” to enter the setting. The illuminated LED (while you continue holding “Stop/Set”) indicates the current value. Change the value using “Open” (up) or “Close” (down), then release “Stop/Set” and wait for the drive to exit the mode within 20 seconds. To check the setting, repeat the procedure without changing the value.
List of adjustable functions:
| Input LED — Name and description | Setting LED — Value |
|---|---|
| L1 — Pause duration If “Automatic closing” is enabled in Level I, this sets the interval between opening and automatic closing. |
L1 — 5 s L2 — 15 s L3 — 30 s L4 — 45 s L5 — 60 s L6 — 80 s L7 — 120 s L8 — 180 s |
| L2 — Step-by-step mode Sets the movement sequence for repeated commands (remote-control button or STEP-BY-STEP/P.P./step-by-step input). Note: with L4, L5, L7 and L8, the behaviour of the “Open” and “Close” commands changes. |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium after two “Stop” commands L6 — Step-by-step after two “partial opening” commands L7 — Hold-to-run L8 — “Semi-automatic” opening; hold-to-run closing |
| L3 — Motor speed Speed during normal operation (not start-up or slowdown). „L6 – Extremely fast” = 100% of 0.34 m/s, etc. |
L1 — Very slow (30%) L2 — Slow (44%) L3 — Medium (58%) L4 — Fast (72%) L5 — Very fast (86%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
| L4 — OGI output indicator Sets the OGI output function (supplies 24 V when activated, −30%/+50%, max. 10 W). |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
| L5 — Motor force Adjusts the force control to suit the weight of the automated gate. The system also takes the ambient temperature into account and increases the force in cold conditions. |
L1 — Extremely light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Medium-heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Extremely heavy gate |
| L6 — Partial opening Opening width in partial-opening mode. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.4 m L8 — 4.0 m |
| L7 — Maintenance alert Number of cycles after which the drive indicates that maintenance is required. |
L1 — 1,000× L2 — 2,000× L3 — 4,000× L4 — 7,000× L5 — 10,000× L6 — 15,000× L7 — 17,000× L8 — 20,000× |
| L8 — Fault log Check the fault type from the last 8 cycles (see “Fault history” in the manual). |
L1 — Result of cycle 1 L2 — Result of cycle 2 L3 — Result of cycle 3 L4 — Result of cycle 4 L5 — Result of cycle 5 L6 — Result of cycle 6 L7 — Result of cycle 7 L8 — Result of cycle 8 |
Automating two opposing sliding gates with two NICE Robus RB600 drives (Master-Slave mode)
If you need to automate two sliding gates facing each other, the Robus drivessupport slave mode (). “Master-Slave” One drive acts as the (masterand sends commands to the other, the slave (drive). All Robus drives are set as master at the factory, so on the slave, enable the Level I function L8 (Slave). The Master ↔ Slave connection is made via BlueBUS.
Limitations when connecting master and slave units
- The gate cannot be opened using the slave unit.
- All devices (e.g. photocells, external receiver etc.) must be connected to the master unit. Only the warning light and devices connected to the STOP, SBS (STEP-BY-STEPinput, and the OGIoutput indicator can be connected to the slave; the OPEN/CLOSE inputs are ignored.
- If you use a backup battery (NICE PSS124), each drive must have its own.
- On the slave unit, all programmed functions are ignored except those listed below.
| Level I programming | Level II programming |
|---|---|
| L4 — Standby mode | L3 — Motor speed |
| L5 — Start-up | L4 — Output indicator |
| L8 — Slave | L5 — Motor force |
| L8 — Error log |
Procedure for installing two Robus drives in slave mode
- Install both gate leaves and both motors. Decide which one will be the Master (N) and which one the Slave (P). In Master-Slave mode, only the slave gate leaf can be fully opened.
- (P) Select the opening direction (direction switch on the control unit).
- (P) On the Slave run device and gate-leaf length acquisition (“Device acquisition”, “Gate-leaf length acquisition”). If the direction is reversed, repeat step 1.
- (P) On the Slave enable the “Master-Slave mode” function (Level I, L8).
- (P+N) Connect the two automation systems according to the diagram.

- (N) Select the opening direction on the Master.
- (N) On the Master run device and gate-leaf length acquisition. The Slave will also move while the gate-leaf length is being acquired. If the direction is reversed, repeat step 6.
Connecting additional external devices
To the control unit
On the MCU1R30 control unit there are 24 V DC (+) and GND (−) for powering external devices, as well as terminals for OGI, BlueBUS and Flash. In Master-Slave connect the devices to the master drive (exceptions for "Slave" see manual – "Master-Slave Mode").
MCU1R30 also allows the connection of an expansion board, which provides additional inputs and outputs.
Expanding the control unit with additional inputs/outputs
The control unit can, in addition to the terminals provided, connect an expansion board. This allows the MCU1R30 unit to be expanded with additional inputs and outputs, making it possible to connect multiple devices. The number and type of inputs and outputs depend on the type of expansion board. For MCU1R30 3 types are currently available of expansion boards:
MLAE21 - 2x 24V inputs (factory-set to Open, Close), 1x 24V output (factory-set to OGI)
MLAE22 - 2x 24V inputs (factory-set to Open, Close), 1x 24V output (factory-set to OGI), 1x 230V output (factory-set to Lighting)
MLAE44 - 4x 24V inputs (factory-set to Open, Close, Partial Opening, Photo), 4x 24V outputs (factory-set to OGI, Gate Closed, Radio Output 4, Phototest)
Procedure for connecting the expansion board:
Adding or removing expansion boards must always be carried out with the power disconnected (by removing fuse F2 and, if connected, the backup battery).
Procedure for learning additional devices.
After adding or removing devices, the automation must be tested again as described in section “Testing” (see manual, item 6.1, on page 24).
Special drive functions
Gate held open
If a command to the STEP-BY-STEP input (P.P., SbS, Step-by-step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is active. Suitable for use with a timer.
Forced operation
If a safety device fails or an obstacle blocks, for example, the photocells and the gate does not move for safety reasons, activate “Hold-to-run mode” — permanently (Level II, L2 = L7) or temporarily:
- Send a command (e.g. remote control or key switch).
- If there is a problem, the gate will not move and the warning light will probably indicate an error.
- Within 3 seconds of the previous command, send it again and hold it.
- The gate moves while the command is held; it stops when the command is released.
Maintenance notification
In Level II programming, item L7 – Maintenance warning sets the number of cycles after which the drive should signal that maintenance (inspection) is required. The drive signals this using the warning light (or, where applicable, via the OGI output, if Level II programming item L4 – Output indicator is set to level L7 – Maintenance) as follows:
| Number of cycles | Warning light indication | OGI output indicator indication |
|---|---|---|
| less than 80% of the limit | Normal operation, flashing at half-second intervals. | “Lit” for 2 seconds after opening begins. |
| 80–100% of the limit | Lit for 2 s after the manoeuvre begins, then operates normally. | Flashes during the manoeuvre. |
| over 100% of the limit | Lit for 2 s after the manoeuvre begins, then operates normally; after the manoeuvre ends, it lights up again for 2 s. | Flashes continuously. |
These settings can also be configured using the mobile app My Nice Pro.
Troubleshooting the drive
If anything is unclear or you have another problem, please feel free to contact our technical support for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
| Problem | Possible solution |
|---|---|
| The gate does not respond to a remote-control command, and the LED on the remote control does not light up. | Check whether the batteries in the drive remote control all right; if not, replace them (instructions are in the manual for the specific controller). |
| The gate does not respond to the remote control command, but the LED on the remote control lights up. | Check whether the remote control was correctly stored in the receiver's memory ; if necessary, program it again. |
| The gate does not move and the BlueBUS LED does not flash. | Check whether the drive is supplied with 230 V. If so, test both fuses and, if necessary, replace them with new ones of the same rating. |
| The gate does not move and the warning light does not flash. | Check whether the drive has registered the command at all: – for a command from the remote control the BlueBUS LED should flash twice quickly; – for a command via the STEP-BY-STEP (SbS) input, the corresponding STEP-BY-STEP LED should light up. |
| The gate does not move and the warning light flashes several times. | Count the flashes and see the section “Diagnostics Using Warning Light Flashes” below. |
| The gate starts moving, but soon stops and reverses. | The motor force is probably set too low. Check for obstructions and, if necessary, increase the force or enable the “Soft Start“. |
| The gate starts moving, but the warning light does not work. | Check whether voltage (approx. 10–30 V DC) is present at the FLASH terminal during operation. If voltage is present, the problem is with the warning light — try replacing it. If there is no voltage, the FLASH output may be overloaded—check the wiring for a short circuit. |
| The gate starts moving, but the OGI output does not work. | Check which function is assigned to the OGI output; if it is meant to flash, check for 24 V DC. If voltage is present, the bulb is faulty—replace it. If there is no voltage, the OGI output may be overloaded—check the wiring for a short circuit. |
Diagnostics Using Warning Light Flashes
While the gate is moving, the warning light flashes regularly once per second. If a problem occurs, it signals the error with two faster consecutive sequences of flashes.
| Flash sequence | Error | Solution |
|---|---|---|
| 1 flash, 1 s pause, 1 flash | BlueBUS error | The devices connected to the BlueBUS input do not match those detected during the setup phase. Repeat the setup phase; if that does not help, use a process of elimination to find the faulty device, then replace it, have it repaired, or claim under warranty. |
| 2 flashes, 1 s pause, 2 flashes | Photocell activation | The photocells are being triggered (common when the beam is interrupted while closing). If the beam was not interrupted, the photocells may be dirty, exposed to glare, or faulty. |
| 3 flashes, 1 s pause, 3 flashes | Motor force limiter activated | The gate is detecting increased friction—check and adjust the gate (test it by moving it manually). Increasing the force or enabling “Soft Start“. The problem may also be caused by an excessively high bottom end stop. |
| 4 flashes, 1 s pause, 4 flashes | STOP input activated | A command was received at the STOP input. If this was not expected, check the connected devices. |
| 5 flashes, 1 s pause, 5 flashes | Internal control unit error | Wait at least 30 seconds and send the command again. If the error persists, try a reset. The control unit will probably need to be repaired or replaced. |
| 6 flashes, 1 s pause, 6 flashes | Hourly movement limit reached | Wait a few minutes for the cycle limiter count to drop below the maximum. |
| 7 flashes, 1 s pause, 7 flashes | Internal electronic circuit error | Disconnect the drive from the power supply for a few seconds, reconnect it, and try sending a command. If the error persists, try a reset. If that does not help, the control unit will probably need to be repaired or replaced. |
| 8 flashes, 1 s pause, 8 flashes | Continuous command active | If a command is being continuously sent to the drive, check the devices connected to the OPEN input. If a timer is connected, it is probably sending this continuous command. |
Diagnostics Using LED Flashes
Diagnostics can be performed by monitoring several sets of LEDs. Two sets are located on the control unit, and the third is the status light directly on the drive.
On the drive...
The status light is located on the front of the cover of the Nice RBS drives.
The red and green LEDs indicate normal operation and provide basic gate diagnostics, as shown in the table below. If the drive detects an anomaly or error, it signals it using the warning light.
| Status light with learned positions | |
|---|---|
| Green light | |
| on | Indicates the start of each gate movement, if there are no anomalies or errors in the system, and turns off when the movement ends. |
| off | Normal operation |
| Red light | |
| on | Indicates the start of each gate movement, if the set number of movements before maintenance has been exceeded; and turns off when the movement ends. |
| off | Normal operation |
| Warning light | The control unit has detected an anomaly. See the table “Diagnosis by flashing beacon.” |
| Status light with positions NOT learned | |
|---|---|
| Green light | |
| on | The light turns on when the opening limit switch is reached. |
| off | Normal operation |
| Red light | |
| on | The light turns on when the closing limit switch is reached. |
| off | Normal operation |
| Beacon | The control unit has detected an anomaly. See the table “Diagnosis by flashing beacon.” |
On the MCU1/MCU1R30 control unit...
MCU1R30 drive control unit NICE Robus RBS800 has two sets of LEDs, each of which indicates normal operation of the control unit or diagnoses faults by flashing and lighting up, as shown in the following tables.
Horizontal LEDs: BLUEBUS, STOP, SbS, FOTO:
| Indicator | Status | Solution |
|---|---|---|
| BlueBUS LED | ||
| off | anomaly/fault | Check the mains connection. If it is correct, check fuses F1 and F2 and, if necessary, replace them with new fuses of the same rating. |
| on | serious fault |
Try disconnecting the control unit, or all inputs. If this does not help, reset the control unit. If the fault persists, the control unit will probably need to be replaced. |
| 2 green flashes at one-second intervals | everything is OK | Normal operation of the control unit. |
| 2 rapid green flashes | the input status has changed |
Normal operation – the status of the STEP-BY-STEP, STOP, OPEN or CLOSE input has changed, or the photocells, or the drive received a command from the remote control. |
| a series of red flashes separated by a one-second pause | various | The number of flashes in the series corresponds to the fault diagnosis shown by the beacon. See “Diagnosis by flashing beacon”. |
| a series of rapid and slow red flashes | short circuit at the BlueBUS terminal | Disconnect the terminal and check the BlueBUS connections to identify the cause of the short circuit. After eliminating the short circuit, reconnect the terminal. The LED will start flashing again after ten seconds. |
| STOP LED | ||
| off | the STOP input has been activated | Check the devices connected to the STOP input. |
| on | the STOP input did not respond | The STOP input is active. |
| STEP-BY-STEP LED (also labelled SbS, P.P. or Step-by-step) | ||
| off | everything is OK |
The STEP-BY-STEP input is inactive. |
| on | the STEP-BY-STEP input has been activated | Normal operation of the control unit if a device connected to the STEP-BY-STEP input has been activated. |
| FOTO LED | ||
| off | The FOTO input has been activated | The FOTO input has been triggered. |
|
on |
Everything is OK | Normal operation of the control unit if the safety device has not been triggered. |
Vertical LEDs L1–L8:
| Indicator | Solution |
|---|---|
| LED 1 | |
| off | During normal operation, indicates that the “Automatic closing” function is disabled. |
| on | During normal operation, indicates that the “Automatic closing” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 2 | |
| off | During normal operation, indicates that the “Close” function after photocell interruption is disabled. |
| on | During normal operation, indicates that the “Close” function after photocell interruption is enabled. |
| flashing |
- The function is being programmed.
|
| LED 3 | |
| off | During normal operation, indicates that the “Always close” function is disabled. |
| on | During normal operation, indicates that the “Always close” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 4 | |
| off | During normal operation, indicates that the “Standby mode” function is disabled. |
| on |
During normal operation, indicates that the “Standby mode” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 5 | |
| off | During normal operation, indicates that the function "Soft start" is disabled. |
| on | During normal operation, indicates that the function "Soft start" is enabled. |
| flashing | Functions are being programmed. |
| LED 6 | |
| off | During normal operation, indicates that the function "Pre-flashing" is disabled. |
| on | During normal operation, indicates that the function "Pre-flashing" is enabled. |
| flashing | Functions are being programmed. |
| LED 7 | |
| off | During normal operation, indicates that the function "Internal radio receiver" is disabled. |
| on | During normal operation, indicates that the function "Internal radio receiver" is enabled. |
| flashing | The function is being programmed. |
| LED 8 | |
| off | During normal operation, indicates that Robus is set as the "Master unit" (also called Master). |
| on | During normal operation, indicates that Robus is set as the "Slave unit" (also called Slave). |
| flashing | The function is being programmed. |
Installing a backup battery in the NICE Robus RBS600 drive
Backup NICE PSS124 battery is not supplied as standard with the drive, but it can be ordered separately. In the event of a power failure, it will power the gate drive. The battery is continuously recharged from the mains. Connect the battery to the control unit only after completing all installation and programming steps.
Manual release of the NICE Robus RBS600 drive
In the event of a power failure or malfunction, you will not be able to operate the gate using the remote control. Therefore, you can release the drive with the release key and move the gate manually.
1. Unlock the locking hook (A) with the supplied key and pull out the release lever. You can now move the gate manually.
2. To lock the gate, close the locking hook, turn the key anticlockwise and remove it.
Technical specifications of the NICE Robus RBS600 drive
| Model | NICE Robus RBS600 |
|---|---|
| Description | Electromechanical geared motor for automatic operation of sliding gates in residential settings. Supplied with NICE MCU1R30 control unit with an integrated radio receiver. |
| Pinion |
|
| Torque [Force] |
21,1 Nm [700 N] – force required to start the gate leaf moving |
| Rated torque [Rated force] |
10 Nm [330 N] – force required to keep the gate leaf moving |
| Speed | 0,34 m/s |
| Maximum consecutive operating cycles | 100 cycles/day (the control unit limits the number depending on the conditions – see drive selection) |
| Duty cycle limit | 7 minutes (the control unit limits the time depending on the conditions – see drive selection) |
| Service life | Approximately 20,000–250,000 cycles, depending on the weight and length of the gate leaf and the drive settings. |
| Power supply | 230 V (+10 % / −15 %) 50/60 Hz |
| Power consumption [Load] |
450 W [2,1 A] |
| Insulation class | 1 – must be earthed |
| Backup power supply | NICE PSS124 backup battery can be purchased separately and installed. (With the use of the adapter CABLA11 an older model can also be used PS124.) |