NICE ROBUS RBS400 - standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€389.79 including VAT
| Weight |
|---|
| 8,00 kg |
Description of NICE ROBUS RBS400 - standalone operator for sliding gates (A)
The NICE Robus RBS400 drive is designed for sliding gates weighing up to 400 kg and with a passage width of up to 8 m. It has an inductive limit switch for the end stops. The drive is non-reversible. The drive is compact, safe and practical, with a shock-resistant cover, and is ideal for both residential and commercial use. Detailed technical specifications ». Drive programming ». Download the manual ».
This product—the standalone NICE Robus RBS400 sliding gate drive (our code NICE-RBS400-A)—includes:
- Electromechanical NICE Robus RBS400 drive with a load capacity of 400 kg, a maximum gate leaf length of 8 m, and a built-in (but removable) MCU1R30 control unit, with a built-in radio receiver and an “SM” connector for a plug-in receiver.
- 2 x release keys for manual operation of the drive (required in the event of a power failure).
- Mounting components for the drive: anchors, mounting plate and magnetic stops for the inductive limit switch.
- Installation manual
One of the main advantages of the Robus RBS400 is its high opening and closing speed, enabled by advanced technology. It features obstacle detection and the option to connect photocells, ensuring maximum safety. It is also equipped with a temperature sensor that adjusts the drive's pulling force to the weather conditions, and is protected by a thermal fuse.
The drive’s high-quality construction, with an IP44 rating, ensures long service life. Robus RBS400 is compatible with Nice accessories. The integrated "Eye Check" system provides visual feedback via an LED light (red/green).
The “Slave unit” function (master-slave mode) allows two motors to be operated in sync, making it possible to automate two sliding gate leaves that open in opposite directions. It is also compatible with the older Robus RB400, but only versions with the RBA3R10 control unit. The older RBA3/c is not compatible with RBS.
The built-in control unit makes operation easy. Programmability is one of this model’s key features.
The built-in bidirectional receiver is ready to program straight away, making connection and operation easy.
Another benefit is the option to add extra functions via an expansion board, including lighting for a safer installation.
User-friendly BlueBUS technology makes it easy to power and control up to 7 pairs of photocells using a two-core cable.
The drive delivers up to 90% energy savings in standby mode and is compatible with the Nice solar kit.
It features a module 4, compatible with the rack in our range.
Thanks to the BiDi-WiFi module (optional accessory), the drive can also be controlled using the mobile MyNice app (Android/iOS) and programmed with MyNice Pro (Android/iOS).
Remote control compatibility:
The drive has a built-in receiver that is compatible with NICE series remotes MYGO, ONE and INTI. The internal receiver does not support FloR or Flo coding. However, the control unit also has an SM connector for a plug-in receiver, which may be useful if you have replaced an old drive with the new RBS and own older-style remotes.
Information for owners of older NICE FLOR remotes:
If you already own older NICE FLOR remotes (models FLO2R-S, FLO2RE, FLO4R-S, FLO4RE), you can continue using them with the new NICE RBS. However, you will need to purchase a plug-in OXIBD receiver or one of the external receivers, such as the NICE OX2.
Extra-long remote control range:
The NICE RBS drive has a slot for an internal receiver, allowing you to install the NICE OXILR receiver with LoRa. You can also connect the NICE OXIFM receiver for additional options.
Information for owners of older NICE FLO and NICE SMILO remotes:
If you use NICE remotes at home with FLO or SMILO, these can also be used with the NICE RBS. However, you must purchase the internal receiver OXIBD, which supports fixed-code signal reception (FLO, SMILO). In this case, the receiver will accept only these older remote models, and newer models cannot be paired at the same time.
Accessories compatible with the Nice Robus RBS400 drive
We recommend purchasing compatible optional accessories for the drive, or choosing one of our pre-assembled drive kits at a discounted price.
| What | Why | Type |
|---|---|---|
| Warning light | Signals gate movement by flashing – suitable for exits with limited visibility. Also includes an antenna for extended remote-control range. |
Or all warning lights with a 12V-24V power supply from other manufacturers. |
| Photocells | They detect obstacles while closing and stop the gate – preventing it from hitting cars or people. | |
| Remote control | For remote control of the gate. | |
| Receiver |
For remote control of the gate. The RBS drive has an integrated radio receiver, but also allows you to connect a plug-in receiver. This makes it easy to upgrade from an older RB drive to a newer RBS without having to pair the remote controls again. |
|
| Programming devices |
|
|
| Antenna | For extended remote-control range. | |
| Keypad | If you forget your remote control or have many vehicles/people and don’t want to give everyone a remote. | |
| Key switch | Operate the gate with a key using a switch wired to the drive. | |
| Card readers | Operate the drive by presenting a card or key fob to the reader. |
|
| Rack | Essential for automation – without a rack, the drive cannot move the gate. | |
| Backup power supply | Keeps the gate operating during a power outage. |
Manuals and documents for download
Nice Robus RBS400 drive manual – PDF
Instructions for pairing remote controls with a Nice drive – link
NICE Robus RBS400 at a glance
NICE Robus RBS is a family of non-reversible electromechanical gear drives for sliding gates. They are supplied with a built-in (removable) NICE MCU1R30 control unit with a built-in receiver and an SM connector for plug-in OXI radio receivers, for example NICE OXIBD. It features an ON-OFF function for deactivating the internal receiver (in Level I programming). The internal receiver does not support FloR or Flo coding.
Electrical connections for external devices ( photocells, warning beacon and so on) in the NICE Robus RBS family were simplified using BlueBUS, which allows multiple devices to be connected to a shared connector using a single two-core cable (with no need to observe polarity). Conventional relay photocells. The control unit MCU1R30 also has an OSE input (Optoelectronic Safety Edge), max. 15 mA.
Automatic operation of the drive depends on the power supply. In the event of a power outage, the motor can be released using the release key. You can also purchase a NICE PSS124 backup battery, which enables operation during a power outage. The older backup power supply NICE PS124 is compatible only when used with the CABLA11 adapter.
The drive has two LEDs: green indicates movement, while red indicates active photocells, abnormal conditions and errors. The limit switch is inductive. Drive functions can also be controlled and configured using the mobile My Nice Pro app (Android/iOS).
Choosing a drive – is the NICE Robus RBS400 drive suitable for my gate?
Every gate has its own size (i.e. lever arm) and weight (i.e. the gravitational force acting on the lever arm), and every drive has its limits. The NICE Robus RBS400 drive is suitable for the following gate leaf lengths and weights:
| Cycles per hour Consecutive cycles |
Gate leaf weight | ||
|---|---|---|---|
| up to 400 kg | up to 600 kg | ||
| Gate leaf length | up to 4 m | 35 | 40 |
| from 8 m | 20 | 20 | |
In general, the gate leaf length determines the maximum number of cycles per hour and consecutive cycles, i.e. it indicates how long the drive can operate. A higher weight reduces these figures proportionally due to the increased load, and also determines the maximum permitted speed for the given load. The drive is equipped with a thermal cut-out that measures the temperature of the motor and its surroundings and reduces the number of possible cycles accordingly.
The stated values apply when the manufacturer's conditions are met (weather conditions, temperatures, rigidity and smooth movement of the gate). In practice, we recommend keeping the total load to around 80% of these parameters.
NICE Robus RBS400 drive limits
The stated values are recommended by NICE. Based on our experience, we recommend allowing a margin of around 20% below the stated values:
| Robus RBS400 | Maximum | Recommended |
|---|---|---|
| Gate leaf length | 8 m | 6 m |
| Gate leaf weight | 400 kg | 320 kg |
Using the drive at its maximum capacity reduces its service life – below is an estimated service-life calculation based on stress factors.
NICE Robus RBS400 drive service life
In the table, add the stress indices for the gate leaf weight and length, then add the indices for other factors (if applicable). Then use the graph to find the drive's service life in number of cycles.
Example: A gate with a clear opening of 4.5 m and a weight of up to 200 kg: length index ~30 + weight index 10 + low-temperature index 10 ⇒ total 40. The graph indicates ~120,000 cycles, which at 10 operations per day is ≈ 32 years.
Installing the NICE Robus RBS400 gate operator
The installation method of the gate operator is different for a track-mounted sliding gate and a cantilever sliding gate . For a track-mounted gate the operator is generally installed at ground level, whereas for a cantilever gate the operator needs to be raised (Ø8 threaded rods, a custom bracket, a concrete plinth, etc.). The key factor is the height of the rack, so that it meshes properly with the operator’s drive gear (see “The rack and its limit stops”).
Wiring
A typical (optional) wiring configuration for the operator and accessories is as follows:
List of accessories
- A – Nice Robus RBS gate operator
- B – Photocells
- C – Photocell posts
- D – Key switch
- E – Flashing light with built-in antenna
- F – Toothed rack
- G – Static safety edge 1
- H – Moving safety edge 1
- I – Opening limit stop
- J – Static safety edge 2
- K – Moving safety edge 2
- L – Closing limit stop
- M – Remote control
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| Power supply | 3 × 1.5 mm² |
30 m For longer distances, use 3 × 2.5 mm² + earth. |
| Flashing light with antenna |
2 × 0.5 mm² 1 × RG58 coaxial cable |
20 m 10 m (recommended < 5 m) |
| Photocells | 2 × 0.5 mm² |
30 m; for over 30 m, use 2 × 1 mm²
Andif the BlueBUS cable is > 30 m (max. 50 m), use 2 × 1 mm². |
| Key switch | 2 cables, each 2 × 0.5 mm² |
50 m
Can be replaced with one 4 × 0.5 mm² cable. |
| Safety edges – static | 2 × 0.5 mm² |
30 m
For multiple static edges, see the manual – “Adding or removing devices / STOP input”. |
| Safety edges – moving | 2 × 0.5 mm² |
50 m
For multiple static edges, see the manual – “Adding or removing devices / STOP input”. |
Installation
The installation height of the operator is one of the requirements for correct operation. More in the article “What height should the operator be installed at?”.
The rack and its limit stops
How it works: the drive gear’s rotary torque is converted into linear motion through the rack-and-pinion mechanism on the toothed rack. The most common types:
| Nylon rack (optionally reinforced with steel) – secured with self-tapping screws through the mounting holes; ideal for lighter/shorter gates, with quieter operation (nylon against a steel gear). | |
| Steel rack – secured by welding threaded brackets in place and then bolting the rack on; suitable for longer/heavier gates, with slightly noisier operation (steel against steel). |
that the operator’s tooth module be compatible with the module of the, that the operator’s tooth module be compatible with the module of the toothed rack. The NICE Robus RBS400 has a tooth module of 4.
The operator detects the open and closed end positions using limit stops mounted on the toothed rack.
Steps for installing the limit stops on the toothed rack:
1. Align the operator and gate. The gate and operator must be level.
2. Leave a 1–2 mm gap between the rack and gear so that the weight of the gate is not transferred to the motor.
3. Tighten the operator’s anchor bolts so that it does not shift when engaged.
4. Move the gate to the open position and adjust the stops so they actuate the switch at the end position.
5. Move the gate to the closed position and adjust the stops so they actuate the switch at the end position.
Wiring the NICE Robus RBS400 gate operator
Before connecting, disconnecting, or changing the wiring of the operator (to the mains or to accessory devices) remember to disconnect the power supply – switch off the circuit breakers, remove the power fuse, or disconnect the backup battery.
WIRING TO THE MAINS
|
For basic operation, you need to run a power supply cable to the operator. |
| The wiring is simple: | |
| L – live (brown) | |
| I – earth/PE (green) | |
| N – neutral (blue) |
WIRING ACCESSORY DEVICES
NICE MCU1R30 control unit for the NICE Robus RBS400 operator provides the following inputs and outputs:
| Input/output | Description |
|---|---|
| FLASH (warning light) |
24 V output for a warning light, e.g. Nice ELDC. |
| OGI (indicator) |
Output for an indicator (24 V). Behaviour configurable in Level II programming, item L4 – Indicator output. |
| PHOTO (photocells) |
Input for photocells. |
| STEP-BY-STEP (SbS, P.P., step-by-step) |
Input for devices that trigger the gate's movement step by step. NO (normally open) contacts can be connected. |
| 24 V (+) | Power supply for external devices (e.g. contactless card reader): 24 V DC, −30% to +50%, max. current 100 mA. |
| GND (ground) |
Ground connection for external devices powered from the 24 V terminal. |
| STOP (stop) |
Input for devices that stop the gate's movement. Possible wiring configurations:
|
| OSE (optical safety edge) |
Interface for an OSE (Optical Safety Edge) sensor, 12 V. |
| BLUEBUS | Input for parallel connection of compatible devices using BlueBUS technology (the two-wire cable provides both power and communication). |
| AERIAL (antenna) |
Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. Nice ELDC, or an external NICE Aerial ABF. |
Operator fuses
The operator contains two fuses:
| Designation | Protection | Type |
|---|---|---|
| F1 | control unit | T 2A 250 V |
| F2 | power supply | T 1.6A 250 V |
|
||
Standard wiring diagram
Operator photocells
User-friendly BlueBUS technology allows you to power and control up to 7 pairs of photocells using a two-wire cable.
Connecting multiple pairs of NICE EPMB photocells to the NICE BlueBUS data network
Position the photocells around the gate according to the example configurations for a complete installation, and set the jumpers according to the jumper configuration table for NICE EPMB photocells. To prevent interference between pairs positioned close together, observe the orientation of the transmitters TX and receivers RX as shown in the example configurations. Connect the photocells in parallel as shown (polarity does not matter):
If you need the photocells to act as gate openers (see FA1 and FA2 in the example configurations), i.e. to trigger the gate to open when a vehicle enters the space between their optical axes, interrupt connection A on both the transmitter TX and receiver RX – see diagram:
Example photocell wiring configuration
NICE EPMB photocell jumper configuration table
![]() |
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations. Each connected pair must have a unique combination; no two pairs in one BlueBUS data network may have the same setting. Set the jumper identically on the transmitter TX and receiver RX within each pair. Keep any unused jumpers for future use. |
| Photocell pair designation | Jumper – jumper combination |
|---|---|
| PHOTO | ![]() |
| PHOTO II | ![]() |
| PHOTO 1 | ![]() |
| PHOTO 1 II | ![]() |
| PHOTO 2 | ![]() |
| PHOTO 2 II | ![]() |
| PHOTO 3 | ![]() |
| FA1 (Break the connection A on both TX and RX) |
![]() |
| FA2 (Break the connection A on both TX and RX) |
![]() |
If you need to replace a photocell, set the same jumper on it as on the original one – there is no need to repeat the device detection procedure.
Radio receiver for gate operators
NICE Robus RBS400 gate operator has a built-in radio receiver in the control unit NICE NICE MCU1R30. The MCU1R30 also provides an SM connector (under the plastic cover) for connecting an external radio receiver NICE OXIBD (or the older NICE OXI). The SM connector makes it easy to upgrade from an older Robus RB operator to a Robus RBS while keeping the already paired remote controls.
Selecting the gate's direction of travel
The direction setting must match the position of the operator relative to the gate leaf. Look at the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
| The switch is on the right-hand side of the back of the control unit. |
|
Detecting connected operator devices
After connecting, disconnecting, or changing the wiring of devices on the BlueBUS and STOP inputs, perform the accessory detection procedure. The operator indicates this by flashing LEDs L1 and L2.
![]() |
|
Detecting the gate-leaf length
To correctly calculate the acceleration/deceleration distance and partial opening, the operator must detect the length of the gate leaf. During the procedure, it moves the gate from one end stop to the other and detects the length using a switch.
Programming the operator
The Robus RBS operator allows you to program several functions, either by switching a function on or off in Level I programming or by setting a preset parameter in Level II programming.
The MCU1R30 control unit has three buttons for operating and programming the gate operator:
Programming – Level I
In Level I programming, you can switch the relevant function on or off.. When a function is enabled, its corresponding LED on the control unit lights up. All functions are disabled by default.
Entering Level I programming Press and hold the “Stop/Set” button for about 5 seconds, until LED L1. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each operation; otherwise, the operator exits the mode. When the flashing LED is next to the function you want to change, press “Stop/Set” to make it flash faster (function enabled) or slower (function disabled), then let the operator exit the mode within 20 seconds. If everything went correctly, the corresponding LED will stay on.
List of functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After the set time (“Level II Programming – Pause Duration”), the gate closes automatically after opening. If this function is disabled, the gate responds only to a command (e.g. from a remote control etc.). |
| L2 | Close after photocell interruption | Once the photocells are clear (the vehicle has passed), closing starts after 5 seconds. Behavior depends on L1:
|
| L3 | Always close | After a power failure, the gate either stays in its original position (disabled) or closes automatically (enabled). |
| L4 | Standby mode | Reduces power consumption to a minimum (useful with PSS124). One minute after the last movement, BlueBUS (and connected devices) and all LEDs except the BlueBUS LED switch off (it flashes slowly). When a command is given, the control unit first wakes up/restarts and only then executes the command. |
| L5 | Start-up | Disables the soft start—the motor immediately runs at full power (useful when there is high friction, snow or ice). Reduces the drive’s service life. |
| L6 | Pre-flashing | Before the gate starts moving, the warning light flashes for 3 seconds, then the manoeuvre begins. |
| L7 | Disable the built-in radio control | Switches off the radio receiver built into the control unit. Enable this if you are using an external plug-in receiver such as the OXI. If this function is disabled, the internal receiver is active. |
| L8 | “Slave” mode – subordinate unit | Activating this function makes the drive a “Slave”. Allows two motors on opposing gate leaves to be synchronized (Master/Slave). For details, see the Robus RBS manual, “Slave Mode” section. |
Programming – Level II
Level II is used to set function values (unlike Level I).
Entering Level II programming Press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each operation; otherwise, the drive exits the mode. When the LED is next to the function whose parameter you want to change, press and hold “Stop/Set” to enter the settings. The LED that is lit (while you continue holding “Stop/Set”) indicates the current value. Change the value using “Open” (up) or “Close” (down), then release “Stop/Set” and wait for the drive to exit the mode within 20 seconds. To verify the setting, repeat the procedure without changing the value.
List of adjustable functions:
| Input LED — Name and description | Setting LED — Value |
|---|---|
| L1 — Pause duration If “Automatic closing” is enabled in Level I, this sets the interval between opening and automatic closing. |
L1 — 5 s L2 — 15 s L3 — 30 s L4 — 45 s L5 — 60 s L6 — 80 s L7 — 120 s L8 — 180 s |
| L2 — Step-by-step mode Sets the movement sequence when a command is repeated (remote-control button or STEP-BY-STEP/P.P./step-by-step input). Note: With L4, L5, L7 and L8, the behavior of the “Open” and “Close” commands changes. |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium after two “Stop” commands L6 — Step-by-step after two “partial opening” commands L7 — Hold-to-run L8 — “Semi-automatic” opening; hold-to-run closing |
| L3 — Motor speed Speed during normal operation (not during start-up or slow-down). „L6 — Extremely fast” = 100% of 0.34 m/s, etc. |
L1 — Very slow (30%) L2 — Slow (44%) L3 — Medium (58%) L4 — Fast (72%) L5 — Very fast (86%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
| L4 — OGI output indicator Sets the function of the OGI output (when activated, it provides 24 V, −30%/+50%, max. 10 W). |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
| L5 — Motor force Adjusts the force control to suit the weight of the automated system. The system also takes the ambient temperature into account and increases the force in cold weather. |
L1 — Extremely light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Medium-heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Extremely heavy gate |
| L6 — Partial opening Passage width for partial opening. |
L1 — 0,5 m L2 — 1,0 m L3 — 1,5 m L4 — 2,0 m L5 — 2,5 m L6 — 3,0 m L7 — 3,4 m L8 — 4,0 m |
| L7 — Maintenance alert Number of cycles after which the drive indicates that maintenance is required. |
L1 — 1 000× L2 — 2 000× L3 — 4 000× L4 — 7 000× L5 — 10 000× L6 — 15 000× L7 — 17 000× L8 — 20 000× |
| L8 — Fault list Check the fault type from the last 8 cycles (see “Fault history” in the manual). |
L1 — Result of the 1st cycle L2 — Result of the 2nd cycle L3 — Result of the 3rd cycle L4 — Result of the 4th cycle L5 — Result of the 5th cycle L6 — Result of the 6th cycle L7 — Result of the 7th cycle L8 — Result of the 8th cycle |
Automating two opposing sliding gates with two NICE Robus RB400 drives (Master-Slave mode)
If you need to automate two sliding gates facing each other, the Robus drives support slave mode (“Master-Slave”). One drive acts as the master (Master) and sends commands to the other, the slave (Slave). All Robus drives are set as master at the factory, so on the slave, enable the Level I function L8 (Slave unit). Connection Master ↔ Slave is made via BlueBUS.
Wiring restrictions for the master and slave units
- The gate cannot be opened using the slave unit.
- All devices (e.g. photocells, external receiver etc.) must be connected to the master unit. Only the warning light, devices connected to the STOP, SBS (STEP-BY-STEP/Step-by-step) input, and the output indicator OGIcan be connected to the slave; the OPEN/CLOSE inputs are ignored.
- If you use a backup battery (NICE PSS124), each drive must have its own.
- On the slave, all programmed functions are ignored except those listed below.
| Level I programming | Level II programming |
|---|---|
| L4 — Standby mode | L3 — Motor speed |
| L5 — Soft start | L4 — Output indicator |
| L8 — Slave unit | L5 — Motor force |
| L8 — Fault log |
Installation procedure for two Robus drives in slave mode
- Install both gate leaves and both motors. Decide which one will be the Master (N) and which one will be the Slave (P). In Master-Slave mode, only the slave gate leaf can be fully opened.
- (P) Select the opening direction (direction switch on the control unit).
- (P) On the Slave perform device and gate-leaf length learning (“Device learning”, “Gate-leaf length learning”). If the direction is reversed, repeat step 1.
- (P) On the Slave enable the “Master-Slave mode” (Level I, L8).
- (P+N) Connect both automation systems according to the diagram.
- (N) Select the opening direction on the Master.
- (N) On the Master perform device and gate-leaf length learning. The Slave will also move while the gate-leaf length is being learned. If the direction is reversed, repeat step 6.
Connecting additional external devices
To the control unit
On the MCU1R30 control unit there is 24 V DC (+) and GND (−) available for powering external devices, as well as terminals for OGI, BlueBUS and Flash. In Master-Slave connect the devices to the master drive (for exceptions for "Slave" see the manual – "Master-Slave Mode").
MCU1R30 also allows connection of an expansion board, which provides additional inputs and outputs.
Expanding the control unit with additional inputs/outputs
The control unit can, in addition to the terminals provided, be connected to an expansion board. This allows the MCU1R30 unit to be expanded with additional inputs and outputs, so that more devices can be connected. The number and type of inputs and outputs depend on the type of expansion board. For MCU1R30 there are currently 3 types of expansion boards to choose from:
MLAE21 - 2x 24V inputs (Open, Close by default), 1x 24V output (OGI by default)
MLAE22 - 2x 24V inputs (Open, Close by default), 1x 24V output (OGI by default), 1x 230V output (Lighting by default)
MLAE44 - 4x 24V inputs (Open, Close, Partial Opening, Photo by default), 4x 24V outputs (OGI, Gate Closed, Radio Output 4, Phototest by default)
Procedure for connecting the expansion board:
Adding or removing expansion boards must always be carried out with the power disconnected (by removing fuse F2 and, if connected, the backup battery).
Procedure for learning additional devices.
After adding or removing devices, the automation must be tested again as described in the section “Testing” (see the manual, section 6.1, page 24).
Special drive functions
Gate held open
If a command to the STEP-BY-STEP input (P.P., SbS, Step-by-step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is held. Suitable for use with a timer.
Forced operation
If a safety device fails or an obstacle blocks, for example, the photocells and the gate does not move for safety reasons, activate the “Hold-to-run” mode—permanently (Level II, L2 = L7) or temporarily:
- Send a command (e.g. remote control or key switch).
- If there is a problem, the gate will not move and the warning light will probably indicate a fault.
- Within 3 seconds of the previous command, send it again and keep it held.
- The gate moves while the command is held; it stops when the command is released.
Maintenance alert
In Level II programming, under item L7 – Maintenance warning you can set the number of cycles after which the drive signals that maintenance (inspection) is required. The drive signals this using the warning light (and, if applicable, the OGI output, if Level L7 – Maintenance is selected under item L4 – Indicator output in Level II programming) as follows: L7 – Maintenanceas follows:
| Number of cycles | Warning light signal | OGI output indicator signal |
|---|---|---|
| less than 80% of the limit | Normal operation, flashing at half-second intervals. | “On” for 2 seconds after opening begins. |
| 80–100% of the limit | On for 2 s after the maneuver starts, then resumes normal operation. | Flashes during the maneuver. |
| more than 100% of the limit | On for 2 s after the maneuver starts, then resumes normal operation; lights up again for 2 s when the maneuver ends. | Flashes continuously. |
These settings can also be configured using the mobile app My Nice Pro.
Troubleshooting the drive
If anything is unclear or you have another problem, feel free to contact our technical support team for NICE drives.
Depending on the nature of the problem
During installation (or if the drive malfunctions), you may encounter one of the following problems:
| Problem | Possible solution |
|---|---|
| The gate does not respond to the remote control command, and the LED on the remote control does not light up. | Check whether the batteries in the drive remote control are in good condition; if not, replace them (instructions are in the manual of the specific remote control). |
| The gate does not respond to the remote control command, but the LED on the remote control lights up. | Check whether the remote control was correctly stored in the memory of the receiver ; if necessary, store it again. |
| The gate does not move and the BlueBUS LED does not flash. | Check that the drive is receiving 230 V power. If it is, test both fuses and, if necessary, replace them with new ones of the same rating. |
| The gate does not move and the warning light does not flash. | Check whether the drive has registered the command at all: – for a command from the remote control the BlueBUS LED should flash rapidly twice; – for a command via the STEP-BY-STEP (SbS) input, the corresponding STEP-BY-STEP LED should light up. |
| The gate does not move and the warning light flashes several times. | Count the flashes and see the section “Troubleshooting using warning-light flashes” below. |
| The gate starts moving, but then stops and reverses. | The motor force is probably set too low. Check that nothing is obstructing the gate and, if necessary, increase the force or enable the “Start-up“. |
| The gate starts moving, but the warning light does not work. | Check whether voltage is present at the FLASH terminal during operation (approx. 10–30 V DC). If voltage is present, the problem is with the warning light – try replacing it. If there is no voltage, the FLASH output may have been overloaded – check the wiring for a short circuit. |
| The gate starts moving, but the OGI output does not work. | Find out which function is assigned to the OGI output; if it should flash, check for the presence of 24 V DC. If voltage is present, the bulb is faulty – replace it. If there is no voltage, the OGI may have been overloaded – check the wiring for a short circuit. |
Troubleshooting using warning-light flashes
While the gate is moving, the warning light flashes steadily once per second. If a problem occurs, it signals an error with two faster flash sequences in succession.
| Flash sequence | Error | Solution |
|---|---|---|
| 1 flash, 1 s pause, 1 flash | BlueBUS error | The devices connected to the BlueBUS input do not match those detected during the recognition phase. Run the recognition phase again; if that does not help, use a process of elimination to find the faulty device and replace it, repair it, or make a warranty claim. |
| 2 flashes, 1 s pause, 2 flashes | Photocell activation | The photocells are being triggered (normal when the beam is interrupted during closing). If the beam was not interrupted, they may be dirty, dazzled by bright light, or faulty. |
| 3 flashes, 1 s pause, 3 flashes | Motor force limiter activated | The gate is detecting increased friction – check and adjust the gate (test its movement by hand). ” may help.Start-up“. may help. The problem may also be caused by an excessively high lower stop. |
| 4 flashes, 1 s pause, 4 flashes | STOP input activated | A command was received at the STOP input. If this was unexpected, check the connected devices. |
| 5 flashes, 1 s pause, 5 flashes | Control unit internal error | Wait at least 30 seconds, then repeat the command. If the error persists, try a reset. The control unit will probably need to be repaired or replaced. |
| 6 flashes, 1 s pause, 6 flashes | Hourly operation limit reached | Wait a few minutes for the cycle limiter to drop below its maximum. |
| 7 flashes, 1 s pause, 7 flashes | Internal electronic circuit error | Disconnect the drive from the power supply for a few seconds, reconnect it, and try the command again. If the error persists, try a reset. If that does not help, the control unit will probably need to be repaired or replaced. |
| 8 flashes, 1 s pause, 8 flashes | Continuous command active | If a command is being continuously sent to the drive, check the devices connected to the OPEN input. If a timer is connected, it is probably sending this continuous command. |
Troubleshooting using LED flashes
Troubleshooting can be carried out by monitoring several sets of LEDs. Two sets can be foundon the control unit, and the third is the status light directly on the drive.
On the drive
The status light is located on the front of the cover of the Nice RBS drives.
The red and green LEDs identify normal operation and provide basic gate diagnostics, as shown in the table below. If the drive detects an anomaly or error, it signals it using the warning light.
| Status light with positions learned | |
|---|---|
| Green light | |
| on | Indicates the start of each gate operation when there are no anomalies or errors in the system, and goes out when the operation ends. |
| off | Normal operation |
| Red light | |
| on | Indicates the start of each gate operation when the set number of operations before maintenance has been exceeded; and goes out when the operation ends. |
| off | Normal operation |
| Warning light | The control unit has detected an anomaly. See the table “Diagnostics using the flashing beacon.” |
| Status light with positions NOT learned | |
|---|---|
| Green light | |
| lit | The light comes on when the opening limit switch is reached. |
| off | Normal operation |
| Red light | |
| lit | The light comes on when the closing limit switch is reached. |
| off | Normal operation |
| Beacon | The control unit has detected an anomaly. See the table “Diagnostics using the flashing beacon.” |
On the MCU1/MCU1R30 control unit
MCU1R30 control unit of the NICE Robus RBS800 drive
MCU1 control unit LEDs
| Horizontal LEDs: BLUEBUS, STOP, SbS, FOTO: | Indicator | Status |
|---|---|---|
| Solution | ||
| BlueBUS LED | off | anomaly/fault |
| Check the mains power connection. If it is OK, check fuses F1 and F2 and, if necessary, replace them with new ones of the same rating. | on |
serious fault Try disconnectingthe control unit, or all the inputs. If that does not help, reset the control unit. |
| If the fault persists, the control unit will probably need to be replaced. | 2 green flashes at one-second intervals | everything OK |
| Normal operation of the control unit. | 2 quick green flashes |
input status changed Normal operation – the status of the STEP-BY-STEP, STOP, OPEN or CLOSE input has changed; photocells were activatedphotocells , or the drive received a command from the. |
| remote control | a series of red flashes separated by a one-second pause | various The number of flashes in the series corresponds to the beacon fault diagnosis. See. |
| “Diagnostics using the flashing beacon” | a series of quick and slow red flashes | short circuit at the BlueBUS terminal Disconnect the terminal and check the BlueBUS connections to find the cause of the short circuit. |
| After clearing the short circuit, reconnect the terminal. The LED will start flashing again after ten seconds. | ||
| STOP LED | off | STOP input activated |
| Check the devices connected to the STOP input. | on | STOP input did not respond |
| The STOP input is active. | ||
| STEP-BY-STEP LED (also labelled SbS, P.P. or Step-by-step) | off |
everything OK |
| The STEP-BY-STEP input is inactive. | on | STEP-BY-STEP input activated |
| Normal operation of the control unit if the device connected to the STEP-BY-STEP input was activated. | ||
| FOTO LED | off | FOTO input activated |
|
The FOTO input has been triggered. |
on | Everything OK |
Normal operation of the control unit if the safety device has not been triggered.
| Vertical LEDs L1–L8: | Indicator |
|---|---|
| Solution | |
| LED 1 | off During normal operation, indicates that the “Automatic closing” |
| function is disabled. | on During normal operation, indicates that the “Automatic closing” |
| function is enabled. |
flashing
|
| - If it flashes at the same time as L2, this means the connected-device detection phase needs to be carried out. | |
| LED 2 | off During normal operation, indicates that the “Close” |
| function that closes the gate after the photocells are interrupted is disabled. | on During normal operation, indicates that the “Close” |
| function that closes the gate after the photocells are interrupted is enabled. |
flashing
|
| - If it flashes at the same time as L1, this means the connected-device detection phase needs to be carried out. | |
| LED 3 | off During normal operation, indicates that the “Always close” |
| function is disabled. | on During normal operation, indicates that the “Always close” |
| function is enabled. |
flashing
|
| - If it flashes at the same time as L4, this means the gate-leaf length detection phase needs to be carried out. | |
| LED 4 | off During normal operation, indicates that the “Standby mode” |
| function is disabled. |
on During normal operation, indicates that the “Standby mode” |
| function is enabled. |
flashing
|
| LED 5 | |
| off | During normal operation, indicates that the “Soft start” function is disabled. |
| on | During normal operation, indicates that the “Soft start” function is enabled. |
| flashing | Functions are being programmed. |
| LED 6 | |
| off | During normal operation, indicates that the “Pre-flashing” function is disabled. |
| on | During normal operation, indicates that the “Pre-flashing” function is enabled. |
| flashing | Functions are being programmed. |
| LED 7 | |
| off | During normal operation, indicates that the “Internal radio receiver” function is disabled. |
| on | During normal operation, indicates that the “Internal radio receiver” function is enabled. |
| flashing | The function is being programmed. |
| LED 8 | |
| off | During normal operation, indicates that Robus is configured as the “Master unit” (also called Master). |
| on | During normal operation, indicates that Robus is configured as the “Slave unit” (also called Slave). |
| flashing | The function is being programmed. |
Installing the backup battery for the NICE Robus RBS400 gate operator
The backup NICE PSS124 battery is not supplied as standard with the gate operator, but it can be ordered separately. If the power supply fails, it will power the gate operator. The battery is continuously recharged from the mains. Connect the battery to the control unit only after completing all installation and programming stages.
Manual release of the NICE Robus RBS400 gate operator
If there is a power failure or malfunction, you will not be able to operate the gate using the remote control. Therefore, you can release the gate operator with the release key and move the gate manually.
1. Unlock the locking hook (A) with the supplied key and pull out the release lever. You can now move the gate manually.
2. To lock the gate, close the locking hook, turn the key anticlockwise and remove it.
Technical specifications of the NICE Robus RBS400 gate operator
| Model | NICE Robus RBS400 |
|---|---|
| Product description | Electromechanical gear motor for the automatic operation of sliding gates in residential settings. Supplied with NICE MCU1R30 control unit with an integrated radio receiver. |
| Pinion |
|
| Torque [Force] |
15,4 Nm [510 N] – force required to start the gate leaf moving |
| Rated torque [Rated force] |
4,5 Nm [150 N] – force required to keep the gate leaf moving |
| Speed | 0,34 m/s |
| Limit on consecutive cycles | 80 cycles/day (the control unit limits the number depending on conditions – see gate operator selection) |
| Operating time limit | 7 minutes (the control unit limits the operating time depending on conditions – see gate operator selection) |
| Service life | Approximately 20,000–250,000 cycles, depending on the weight and length of the gate leaf and the gate operator settings. |
| Power supply | 230 V (+10 % / −15 %) 50/60 Hz |
| Power consumption [Load] |
250 W [1,1 A] |
| Insulation class | 1 – must be earthed |
| Backup power supply | NICE PSS124 backup battery available to purchase and install separately. (With the use of the adapter CABLA11 you can also use the older model PS124.) |
360° view of the Nice Robus RBS400 drive
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]





























