NICE Robus RB400 - standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€393.58 including VAT
| Weight |
|---|
| 9,00 kg |
Description of NICE Robus RB400 - standalone operator for sliding gates (A)
The NICE RB400 operator has been replaced by a newer model NICE RBS400. See the benefits of the newer NICE RBS400 and RBS600 models.
NICE Robus RB400 gate opener is designed for sliding gates weighing up to 400 kg and a passage width of up to 7 m. It has an electromechanical stop switch. The gate opener is non-reversible. Detailed technical specifications ». Download the manual ».
(Is this gate opener right for me?)
Compare with other gate openers:
| « Lower-powered gate opener | Alternative gate opener | Higher-powered gate opener » |
|---|---|---|
|
No. |
|
|
This product—the standalone NICE Robus RB400 sliding gate opener (our code NICE-RB400-A)—includes:
- electromechanical NICE Robus RB400 gate opener with a capacity of 400 kg and a maximum gate leaf length of 7m, with a built-in (but removable) control unit RBA3R10 without radio receiver (OXI).
- 2 × release keys for manual operation of the gate opener (required in the event of a power outage)
- gate opener mounting components, anchors and bracket, limit-stop plates for the gate opener
- installation manual
Discounted kits containing a gate opener NICE Robus RB400:
| Gate opener kit with accessories » | Gate opener kit with accessories and rack » |
|---|---|
|
Robus gate opener for gates up to 400 kg, remote control, photocells and warning light. |
ROBUS gate opener for gates up to 400 kg, rack, remote control, photocells and warning light. |
| Cantilever gate manufacturing kit » | Track gate manufacturing kit » |
Trolleys with 5 bearings, 6m Fe C-track, guide-in ramp, receiver channel, guide, gate opener and rack. |
Ø90 mm wheels, 3 × 3m Zn track, lower stops, guide, gate opener and rack |
The gate opener is compact, safe and practical, ideal for both residential and commercial use. Impact-resistant cover, with an aluminium-alloy body and epoxy coating.
The gate opener is suitable for automating sliding gates weighing up to 400 kg, with a gate leaf length of up to 7 m. These figures apply under the conditions specified by the manufacturer, including weather conditions, temperature variations, gate rigidity and, above all, smooth gate movement. These conditions are not always achievable or controllable, so we recommend using the NICE Robus RB400 gate opener ideally for gates operating at 80% of these limits. See the Choosing a gate opener chapter for more information.
Highly user- friendly technology BlueBUS allows to power and control up to 7 pairs of photocells using a two-core cable.
The temperature sensor adjusts the gate opener's driving force according to the climatic conditions. The gate opener also includes a thermal cut-out.
Adjustable speed,, force and pause time of automatic drive closing and much more, see Programming.
Diagnostics using warning light.
Gearwheel module 4 is compatible with the toothed rack in our range.
Robus 400 drive function "Slave unit" ensures automatic synchronisation of two motors. This means that two sliding gates moving towards each other can be automated.
The NICE Robus RB400 drive is an electromechanical operator suitable for Slovakia’s climatic conditions and meets all European safety standards.
Accessories compatible with the NICE Robus RB400 drive
We also recommend purchasing compatible optional accessories for the drive, or choosing one of our pre-assembled discounted kits:
| What | Why | Type |
|---|---|---|
| Warning light | The warning light flashes to indicate gate movement—ideal for exits with limited visibility. It also has a built-in antenna for extended remote-control range. | - LED warning light with antenna ELDC - multifunctional light WLT - wireless solar LED warning light LLW |
| Photocells | When closing, they detect an obstacle and stop the gate—preventing it from hitting cars or people. | - Era Photocell Medium EPMB - Era Photocell Large EPLB - Era Photocell Slim EPSB - wireless FT210B - wireless EPMOW - solar-powered PHW |
| Transmitter | For remote control of the gate. | - Era One ON2E, ON3EBD, ON3ELR, ON4E, ON9E - Era Flor Flo2RE, Flo4RE - FloR Flo2R-s, Flo4R-s - Inti INTI2, INTI2Y, INTI2L, INTI2B, INTI2R, INTI2G |
| Receiver | Required for remote control of the gate. | - OXI - OXIBD - OXILR - Wi-Fi receiver IT4WIFI - GSM receiver GSM LITE3+, GSM SMART3, GSM PROFI3 |
| Antenna | For improved remote-control range. | - integrated into the warning light ELDC - standalone antenna ABFKIT |
| Keypad | If you forget your remote control, or if many vehicles or people visit and you don't want to give everyone a remote or open the gate manually. | - wireless EDSWG - wired EDSB |
| Key switch | For operating the gate with a key via a switch connected to the drive by cable at any location. | - surface-mounted, with a standard cylinder EKS - surface-mounted, with a European cylinder, EKSEU - flush-mounted, with a standard cylinder EKSI - flush-mounted, with a European cylinder EKSIEU |
| Card readers | Operate the drives by presenting a card or key fob to the card reader. | - ERA Transponder Reader ETPB |
| Gearing | Essential for automating the drive—without a rack, the drive has nothing to move the gate with. | - nylon, with steel reinforcement, 33 cm LZ-1 - nylon, with steel reinforcement, 1 m LZ-10 - nylon, with steel reinforcement, reverse, 1 m LZ-15 - steel, 30x8mm, 1 m LZ-3 - steel, 30x12mm, 1 m LZ-5 - stainless steel, 30x10mm, 1 m LZ-7 |
| Backup power supply | Keeps the gate operating in the event of a power outage. | - backup battery PS124 - solar power supply SYKCE |
Manuals and documents for download
NICE Robus RB400 at a glance
NICE Robus is a range of irreversible electromechanical geared drives for sliding gates. They are supplied with a built-in (but removable) NICE RBA3R10 control unit with an SM connector for external receivers radio signal NICE SMXI, or alternatively NICE OXI. Electrical connections for external devices (photocells, warning beacon, etc.) have been simplified in the NICE Robus sliding gate drive range by using BlueBUS, which allows several devices to be connected to a shared connector using just one two-core cable, with no need to observe polarity. Automatic operation depends on a power supply, but in the event of a power failure, the geared motor can of course be released using a special release key so the gate can be operated manually. It is also possible to purchase an optional NICE PS124 backup battery, which allows the gate drive to be operated during a power outage.
Choosing a drive—is the NICE Robus RB400 suitable for my gate?
Every gate has its own size (and therefore its own leverage) and weight (and therefore the force exerted by its weight) and every drive has its limits. The drive NICE Robus RB400 can be used for the following gate leaf lengths and weights:
| Cycles per hour Consecutive cycles |
Gate leaf weight | ||
| Up to 200kg | 200-400kg | ||
|---|---|---|---|
|
L |
Up to 4m |
35 |
16 |
| 4-6m | 23 11 |
11 5 |
|
| 6-7m | 20 10 |
10 5 |
|
In principle gate leaf length determines the maximum number of cycles per hour and also consecutive cycles, i.e. it specifies how long the operator can remain in operation. A higher weight further reduces the number of these cycles by a percentage, due to the greater strain on the operator, and also determines the maximum permissible speed at that load. The operator is equipped with a device (thermal cut-out), which measures both the motor temperature and the ambient temperature and reduces the number of possible cycles accordingly.
NICE Robus RB400 operator limits
The values shown are those recommended by NICE. Based on our experience, we recommend allowing a margin of approximately 80% of the stated values:
| Maximum | Recommended | |
|---|---|---|
| Gate leaf length | 7 m | 5 m |
| Gate leaf weight | 400 kg | 320 kg |
Operating the operator at its maximum capacity, however, reduces its service life — see the estimated operator service life based on stress factors:
NICE Robus RB400 operator service life
In the following table, add the stress indexes for the weight and length of the gate leaf, then add the indexes for any other applicable factors. Then use the graph to determine the operator's service life in number of cycles.
Example: I have a gate with a clear opening of 4.5 m and a construction weight, including infill, of up to 200 kg (a standard gate). I calculate the gate leaf length index as approximately 15, plus the gate weight index of 10. To be on the safe side, I add an index of 10 for lower temperatures because our winters are harsher, giving a total index of 35. The graph shows that the operator's service life is approximately 120,000 cycles. At 10 operating cycles per day, this corresponds to a service life of approximately 32 years.
| Properties of the complete automation system | Index | Service life graph |
|---|---|---|
| Gate leaf weight |
The recommended maximum total index is up to 75%. (i.e. 40,000 cycles, which is 10 years at a typical usage rate of 10 cycles per day)
|
|
| Up to 200 kg | 15 | |
| 200-400 kg | 50 | |
| Gate leaf length | ||
| Up to 4 m | 15 | |
| 4-6 m | 30 | |
| 6-7 m | 50 | |
| Other factors (if the probability of occurrence is greater than 10%) | ||
| Ambient temperature above 40°C or below 0°C, or humidity above 80% | 10 | |
| Dusty environment | 15 | |
| Saline environment | 20 | |
| Photocell activation | 15 | |
| STOP input activation | 25 | |
| Speed higher than "L4 - Fast" | 20 | |
| Peak function active | 25 | |
Installing the NICE Robus RB400 operator
The installation method for the operator differs for a track sliding gate and a cantilever sliding gate different. For a track gate the operator is usually operator installed at ground level; for a cantilever gate it needs to be operators raised using, for example, threaded rods (M8 threaded rod), a custom-made bracket, a concrete plinth, etc. The decisive factor is the height of the toothed rack, which should ideally mesh with the operator's drive gear; see Toothed rack and its end stop.
Wiring
A typical (optional) wiring setup for the operator and accessories looks as follows:
List of accessories
|
|
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| A. Power supply | 3×1.5mm2 | 30m, for longer lengths 3×2.5mm2 + grounding |
| B. Flashing light with antenna |
2×0.5mm2 |
20m 20m (recommended: less than 5m) |
| C. Photoelectric cells | 2×0.5mm2 | 30m, over 30m use 2×1mm2 |
| D. Key switch | 4×0.5mm2 | 50m (or 2 pcs. 2×0.5mm2) |
| E. Fixed safety edges | 2×0.5mm2 | 30m |
| F. Movable safety edges | 2×0.5mm2 | 30m |
Installation
See "What height should I install the drive at".
Rack and its end stop
The gate moves by transferring the drive sprocket’s rotary torque into linear motion via the rack-and-pinion transmission on the drive rack. The two most commonly used types of racks are:
|
Nylon rack (optionally with steel reinforcement) – attaches to the gate with self-tapping screws through the eyelets. Ideal for relatively lighter and shorter gates. Movement is quiet thanks to the friction between the steel drive sprocket and the nylon rack. |
|
|
Steel rack – attaches to the gate by welding on threaded brackets, which the rack is then screwed into. Used for longer and heavier gates. Movement is slightly noisier because of the friction between the steel drive sprocket and the steel rack. |
The key requirement is that the drive tooth module is compatible with the rack module. Drive NICE Robus RB400 has a tooth module of 4.
The drive detects the end position when opening and closing using limit stops fitted to the rack:
Wiring the NICE Robus RB400 drive
Before connecting, disconnecting, or changing the wiring of the drive to the mains or of any accessories, remember to disconnect the power supply, either at the circuit breaker, by removing the power fuse, or by disconnecting the backup battery.
...to the mains
![]() |
To operate the drive, you only need to connect the drive to the power supply.
The wiring is simple:
|
...accessories
NICE RBA3R10 control unit drive NICE Robus RB400 provides the following inputs and outputs for accessories:
| Input/output | Description |
|---|---|
| Output for up to two 12 V warning lights NICE LUCYB (or NICE MLBT) with one 12 V 21 W bulb | |
| S.C.A. (Indicator) |
Output for an indicator (24 V, 4 W). Its operation can be configured by programming Level II, item L4; see Level II programming, L4 – Indicator output. |
| Input for parallel connection of compatible devices using BlueBUS using a two-core cable that carries both the power supply and the communication signal. | |
| STOP (Stop) |
Input for devices that stop gate movement. The following devices can be connected:
|
| Input for devices that control gate movement step by step (see Step-by-step gate movement). Normally open devices (NO) can be connected. | |
| OPEN (Open) |
Input for devices that control gate opening (see Gate opening). Normally open devices (NO) can be connected. |
| CLOSE (Close) |
Input for devices that control gate closing (see Gate closing). Normally open devices (NO) can be connected. |
| AERIAL (Antenna) |
Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. NICE LUCYB, NICE MLBT, or a separate external antenna can be used NICE ABFKIT. |
Gate opener fuses
|
The gate opener contains two fuses:
|
||||||||||||
Standard wiring diagram:
Gate opener photocells
The very user-friendly BlueBUS technology allows you to power and control up to 7 pairs of photocells using a two-core cable.
Connecting multiple pairs of photocells NICE EPMB to the data network NICE BlueBUS
Position the photocells around the gate or gates according to the example configurations for complete wiring, and set the jumpers according to the jumper table for the NICE EPMB gate opener. To prevent interference between pairs installed close to one another, make sure to follow these example configurations, and observe the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you need the photocells to work as gate openers (see FA1 and FA2 in the example configurations), i.e. when a vehicle passes between their optical axes, causing the gate to open, you must cut the link A on both the transmitter TX and receiver RX, see diagram:
Example photocell wiring diagram
NICE photocell jumper table EPMB gate operator
![]() |
Connecting multiple pairs of photocells to the system BlueBUS is done by setting different jumper combinations, with each connected pair requiring a unique jumper combination. Make sure that no two pairs in the same BlueBUS data network have the same combination. Set the jumper on both the TX transmitter and RX receiver in each pair of photocells to the same value. If a jumper configuration uses only one or no jumper, always keep the remaining jumpers for future use. |
| Photocell pair designation | Jumper configuration |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
| FOTO 3 | ![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If a photocell needs to be replaced for any reason, simply set it to the same jumper as the original one; there is no need to run the device learning procedure.
Radio receiver for gate operators
![]() |
NICE Robus RB400 gate operator is supplied with NICE RBA3R10 control unit, which has an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands sent by from remote controls, and is therefore required for remote operation of the sliding gate using a remote control. |
Selecting the gate travel direction
The sliding gate opening direction must be selected according to the position of the operator relative to the sliding gate leaf. Look at the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
The switch is located on the right-hand side of the RBA3R10 control unit in the middle.
Learning the connected gate operator devices
After connecting, disconnecting or changing the wiring of any accessories to the BlueBUS inputs and STOP the following procedure must be carried out: learning the connected accessories. The operator will alert you that this procedure is required by flashing LEDs L1 and L2.
![]() |
|
Evaluating the gate leaf length
For the gate to operate correctly (specifically, to calculate the acceleration and deceleration distances and partial opening), the drive must determine the gate leaf length itself. During this operation, the drive moves the gate from one stop to the other and uses a switch to determine the gate length.
![]() |
|
Programming the drive
The Robus drive allows you to program various functions, either by switching a function on or off using Level I programming,or by setting a preset parameter using Level II programming.
RBA3R10 control unit has three buttons for operating and programming the drive:
![]() |
Button | Function |
|---|---|---|
| Open | The button sends the drive an open-gate command. During programming, it also moves the value of the parameter being programmed up. | |
| Stop/Set | The button sends the drive a stop-gate command. Pressing and holding it for 5 seconds the first time takes you into Level I programming. Pressing and holding it again takes you into Level II programming. for the currently selected LED. | |
| Close | The button sends the drive a close-gate command. During programming, it also moves the value of the parameter being programmed down. |
Level I programming
At Level I, programming turns the selected function on or off. When a function is enabled, the corresponding LED on the control unit lights up. All functions are disabled by default.
To enter Level I programming, press and hold the “Stop/Set” button for about 5 seconds, until the L1 LED starts flashing. Then use the “Open” and “Close” buttons to move the selected LED up or down. You have 10 seconds for each operation; otherwise, the drive will exit programming mode. When the flashing LED is above the LED for the function you want to enable or disable, press the “Stop/Set” button once to make it flash faster (function enabled) or slower (function disabled), then leave it as is and let the drive exit programming mode within 10 seconds. If everything went well, the corresponding LED for the function being enabled will stay lit.
List of programmable functions:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After a set time (adjusted under “Level II programming – Pause duration”), the gate will start closing automatically after it opens. If this function is disabled, the gate can only be operated using a command from the gate remote control or similar. |
| L2 | Close after photocell interruption |
This function keeps the gate open only for as long as necessary for a vehicle to pass through. When the photocells are cleared (after the vehicle has passed through), the gate will start closing automatically after 5 seconds. This function operates in two ways, depending on whether automatic closing is enabled (see the previous function). Automatic closing enabled – the gate stops when the photocells are cleared and starts closing after 5 seconds. This means it may not open all the way. |
| L3 | Always close | After a power failure, the gate either stays as it was (if this function is disabled) or closes (if this function is enabled). |
| L4 | Standby mode | This function minimizes power consumption. It is ideal when using a backup battery (e.g. NICE PS124). When this function is enabled, one minute after the gate's last movement, the control unit switches off the BlueBUS input (and therefore all devices connected to it) and all LEDs except the BlueBUS LED, which flashes slowly. In this state, if a command is received, control unit restarts first, then carries out the command. |
| L5 | Soft start | Disables the drive's gradual start at the beginning of a cycle, making the drive start full force. Suitable when there is high friction or when snow and ice need to be broken through, so this function is mainly useful in winter. On the other hand, it reduces the drive's service life. |
| L6 | Pre-flashing | After receiving a gate movement signal, the beacon flash for three seconds to warn people nearby, and only then does the requested movement begin. |
| L7 | Close means Partial opening | A close close always starts the partial opening of the gate. |
| L8 | Slave unit | Enabling this function is useful when installing two automated sliding gates facing each other – one drive is the master of the other. The slave drive has this function enabled and is synchronized with the master drive via the BlueBUS input. For more information, see Robus in slave unit mode. |
Level II programming
At Level II, programming sets values for the functions (these functions differ from those in Level I).
Forget Level I programming. To enter Level II programming, press and hold the “Stop/Set” button for approx. 5 seconds, until the LED L1. Then use the “Open” and “Close” buttons to move the current LED up or down. You have 10 seconds for each operation; otherwise, the drive exits programming mode. When the flashing LED reaches the LED for the function whose parameter you want to set, press and hold the “Stop/Set” button to enter the settings for that LED. The LED that remains lit (while you continue holding “Stop/Set”) indicates the current parameter value. You can change this value up or down using the “Open” and "Close” buttons (continue holding “Stop/Set”), then release “Stop/Set” and wait for the drive to exit programming mode within 10 seconds. To check that everything worked correctly, repeat the procedure without changing the parameter value.
List of programmable functions and settings:
|
Input LED — Name |
Setting LED — Value |
|---|---|
| L1 — Pause duration If the “Automatic closing” function is enabled in Level I programming, |
L1 — 5 seconds L2 — 15 seconds L3 — 30 seconds L4 — 45 seconds L5 — 60 seconds L6 — 80 seconds L7 — 120 seconds L8 — 180 seconds |
|
Sets the gate movement sequence triggered by repeatedly pressing, for example, a button on the gate remote, or by activating the STEP-BY-STEP input (also known as P.P.or Step-by-step mode). |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium after two Stop commands L6 — Step-by-step, then partial opening L7 — Hold-to-run L8 — Semi-automatic opening, hold-to-run closing |
|
Sets the gate's speed during normal operation (not during acceleration or deceleration). |
L1 — Very slow (30%) L2 — Slow (45%) L3 — Medium (55%) L4 — Fast (70%) L5 — Very fast (85%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
|
Sets when a signal is sent to the S.C.A. output (24 V -30% +50%, maximum power 4 W) |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
|
Indicates the motor force control system the weight of the gate. This system also measures the ambient temperature and automatically adjusts the motor force, for example by increasing it at very low temperatures. |
L1 — Ultra-light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Moderately heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Ultra-heavy gate |
|
Sets the travel distance for partial opening. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.5 m L8 — 4.0 m |
|
Sets the number of gate cycles after which the drive will indicate that maintenance is required. |
L1 — Automatically (the drive calculates this itself based on the difficulty of the cycles) L2 — 1000 × L3 — 2000 × L4 — 4000 × L5 — 7000 × L6 — 10000 × L7 — 15000 × L8 — 20000 × |
|
Plays the type of the last up to 8 error messages. |
L1 — Result of cycle 1 L2 — Result of cycle 2 L3 — Result of cycle 3 L4 — Result of cycle 4 L5 — Result of cycle 5 L6 — Result of cycle 6 L7 — Result of cycle 7 L8 — Result of cycle 8 |
Automating two opposing sliding gates with two NICE Robus RB400 drives
If you need to automate two sliding gates facing each other, drives Robus drives can be connected in slave mode. The operating principle is that one drive acts as the master and sends commands to the other, slave.. All Robus drives are configured as master by default, so this parameter must be set on the slave drive in Level I programming. using function L8 - slave.
Restrictions on connecting master and slave units
- The gate driven by the slave unit can only be opened fully (there is no option to partial opening).
- All devices (photocells, receiver, etc.) must be connected to the master unit. Only the following may be connected to the slave unit: warning light, S.C.A. output indicator, devices for the STOP input and P.P. (also called STEP-BY-STEP, or Step-by-step), OPEN inputs and CLOSE are ignored.
- If you want to use a backup battery (NICE PS124), each drive must have its own.
- All functions programmed on the slave unit are ignored except for those programmed in:
| Level I programming. | Level II programming. |
|---|---|
| L4 - Standby mode | L3 - Motor speed |
| L5 - Peak | L4 - Output indicator |
| L8 - Slave | L5 - Motor force |
| L8 - Fault log |
Installation procedure for two Robus drives in slave mode
1. Install the gates and drives and set the opening directions as follows:
2. Wire the drives according to the diagram (observe the polarity of the BlueBUS wiring connection between the drives):
3. Connect power supply to both drives
4. In Level II programming, set the parameter on the slave unit L8 - Slave unit
5. Run the connected-device learning phase on the slave unit
6. Run the connected-device learning phase on the master unit
7. Run the leaf-length learning phase on the master unit
Connecting additional external devices to the drive
![]() |
If you need to connect additional devices to the drive that require an external power supply (e.g. indicator lighting, key switch, magnetic cards, etc.), connect the device as shown in the diagram. The supplied voltage is 24Vdc -30% to +50%, with a maximum current of 100mA. |
Special drive functions
Gate held open
If the command on the STEP-BY-STEP input (also called P.P. or Step-by-Step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is active. This function is particularly useful when used with a timer.
Hold-to-run operation
If a safety device fails or, for example, an obstacle that cannot be removed enters the beam of the photocells and the gate will not move for safety reasons, you can activate the “Hold-to-run” mode, either permanently in Level II programming under setting L2 - Step-by-step mode to L7 - Hold-to-run, or temporarily:
- Send a command to the gate using the (remote control, key switch etc.)
- If there is a problem, the gate will not move and the warning light will probably indicate a fault.
- Therefore, within 3 seconds of the previous command, send the command again and hold it.
- The gate will move while you hold the command and stop as soon as you release it.
Maintenance alert
In Level II programming item L7 - Maintenance alert you can set the number of cycles after which the drive should signal that maintenance (inspection) is required. The drive signals this using the warning light (or via the S.C.A. output, if configured in Level II programming under item L4 - Output indicator level L7 - Maintenance) as follows:
| Number of cycles | Warning light signal | Signal from S.C.A. output indicator |
|---|---|---|
| less than 80% of the limit | Normal operation; flashes at half-second intervals. | “On” for 2 seconds after opening starts. |
| 80-100% of the limit | On for 2s after the manoeuvre starts, then continues operating normally. | Flashes during the manoeuvre. |
| over 100% of the limit | On for 2s after the manoeuvre starts, then continues operating normally; on for 2s after the manoeuvre ends. | Flashes continuously. |
For instructions on clearing the maintenance alert and checking the current number of manoeuvres against the limit, see section 7.4.3 of the manual.
Troubleshooting the drive
If anything is unclear or you have any other problem, feel free to contact our technical support team for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
The gate does not respond to a remote-control command, and the LED on the remote control does not light up. |
Check whether the batteries drive remote control are in good condition; if not, replace them. You can find the instructions in the manual for the specific control unit. |
|
The gate does not respond to the remote control, but the LED on the remote control lights up. |
Check whether remote control was stored in the memory of the receiver is working properly, or try remote control to save it again. |
|
The gate does not move and the BlueBUS LED does not flash.
|
Check whether the drive is supplied with 230V. If so, test both fuses and replace them, if necessary, with new fuses of the same rating. |
|
The gate does not move and the warning light does not flash. |
Check whether the drive has registered the command at all. When a command is sent using the remote control should the BlueBUS LED flash quickly twice. If the command is sent by another device via the STEP-BY-STEP input (P.P.), the corresponding STEP-BY-STEP LED. |
|
should light up. The gate does not move and the warning light flashes several times. |
Count the number of flashes and see Warning light flash diagnostics. |
|
The gate starts moving, but stops immediately and starts moving in the opposite direction. |
The programmed motor force is probably too low for your gate. Check that nothing is obstructing the gate's movement and, if necessary, increase the drive force or enable the Peak. |
|
The gate starts moving, but the warning light does not work. |
Check whether there is voltage at the FLASH output during gate operation (the voltage level is not important, approx. 10-30Vdc). If there is voltage at the output, the problem is likely with the warning light. Try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded. Check whether the wiring has short-circuited. |
|
The gate starts moving, but the S.C.A. output does not work. |
Find out which function is programmed for the S.C.A. output and, if the output should flash, check whether voltage is present (approximately 24Vdc). If there is voltage at the output, the problem is likely with the bulb. Try replacing it with a similar one to see if it works. If there is no voltage at the output, the S.C.A. output may be overloaded. Check whether the wiring has short-circuited. |
Warning light flash diagnostics
During gate operation, the warning light flashes regularly every second. If a problem occurs, the warning light indicates an error with two consecutive, faster sequences of flashes.
|
Flash sequence |
Error |
Solution |
|---|---|---|
|
1 flash 1-second pause 1 flash |
BlueBUS error
|
Devices connected to the BlueBUS input do not match those detected during the device detection phase. Run the detection phase again. If that does not help, try once more; otherwise, use the elimination method to find the faulty device and replace it (buy a replacement, make a warranty claim, or have it repaired). |
|
2 flashes 1-second pause 2 flashes |
Photocell activation |
The photocellsare being activated, which is normal if their beam is interrupted while the gate is closing. If the beam was not interrupted, the photocells may be dirty, exposed to bright light, or faulty. |
|
3 flashes 1-second pause 3 flashes |
Motor force limiter activated
|
While the gate is moving, check for increased friction—you may need to adjust the gate. Try moving it by hand and readjusting it. Otherwise, it usually helps to increase the motor forceor enable the Peak function. Another possible cause is that you have the bottom stop set too high. |
|
4 flashes 1-second pause 4 flashes |
STOP input activated
|
A command was sent to the STOP inputso, if this was unexpected, check the devices connected to it. |
|
5 flashes 1-second pause 5 flashes |
Internal control unit error |
Wait 30 seconds and try again. If the problem persists, try to reset it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
6 flashes 1-second pause 6 flashes |
The hourly operating limit has been reached. |
Wait a few minutes for the cycle limiter to drop below the limit. |
|
7 flashes 1-second pause 7 flashes |
Internal electronic circuit error. |
Disconnect the entire drive for a few seconds and try again. If it persists, try resetting it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
8 flashes 1-second pause 8 flashes |
Continuous command active.
|
A command is being continuously sent to the operator—try checking the devices connected to the OPEN input. If you have a timer connected, it is probably the cause.
|
Diagnostics using LED flashing
On the RBA3R10 control unit of the NICE Robus RB400 operator there are two sets of LEDs, each of which indicates normal operation of the control unit or diagnoses faults by flashing or lighting up, as shown in the tables below.
Horizontal BLUEBUS, STOP, PP, OPEN and CLOSE LEDs
|
Indication |
Status |
Solution |
|---|---|---|
|
BlueBUS LED |
||
|
Off |
Error
|
Check the mains connection, and if it is OK, check fuses F1 and F2 and replace them, if necessary, with new fuses of the same rating. |
|
On |
Serious error
|
Try disconnecting the control unit, or all inputs. If that does not help, reset it. If that still does not help, the control unit will probably need to be replaced. |
|
Flashing at one-second intervals |
Everything is OK |
The control unit is operating normally. |
|
2 quick flashes |
Input status changed |
Normal operation—the status of an input has changed STEP-BY-STEP, STOP, OPEN, CLOSE, were activated photocells, or the operator received a command from the remote control. |
|
Flashing sequences separated by a one-second pause |
Several possibilities |
The number of flashes in a sequence corresponds to the fault diagnosis indicated by the warning light. |
|
STOP LED |
||
|
Off |
The STOP input has been activated |
Check the devices connected to the STOP input. |
|
On |
Everything is OK |
The STOP input is not active. |
|
STEP-BY-STEP LED (also marked P.P., step-by-step) |
||
|
Off |
Everything is OK |
STEP-BY-STEP input is not active. |
|
On |
The STEP-BY-STEP input has been activated |
Normal operation of the control unit, if an active device was connected to the STEP-BY-STEP input. |
|
OPEN LED (Open) |
||
|
Off |
Everything is OK |
The OPEN input is not active.
|
|
On |
The OPEN input has been activated |
Normal operation of the control unit, if an active device was connected to the OPEN input. |
|
CLOSE LED (Close) |
||
|
Off |
Everything is OK |
The CLOSE input is not active.
|
|
On |
The CLOSE input has been activated |
Normal operation of the control unit, if an active device was connected to the CLOSE input. |
Vertical L1–L8 LEDs
|
Indication |
Solution |
|---|---|
|
LED 1 |
|
|
Off |
During normal operation, indicates that the Automatic closing function is disabled. |
|
On |
During normal operation, indicates that the Automatic closing function is enabled. |
|
Flashing |
|
|
LED 2 |
|
|
Off |
During normal operation, indicates that the Close after photocell interruption function is disabled. |
|
On |
During normal operation, indicates that the Close after photocell interruption function is enabled. |
|
Flashing |
|
|
LED 3 |
|
|
Off |
During normal operation, indicates that the Always close function is disabled. |
|
On |
During normal operation, indicates that the function Always close is enabled. |
|
Flashing |
|
|
LED 4 |
|
|
Off |
During normal operation, indicates that the Standby function is disabled. |
|
On |
During normal operation, indicates that the Standby function is enabled. |
|
Flashing |
|
|
LED 5 |
|
|
Off |
During normal operation, indicates that the function Peak is disabled. |
|
On |
During normal operation, indicates that the function Peak is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 6 |
|
|
Off |
During normal operation, indicates that the function Pre-flashing is disabled. |
|
On |
During normal operation, indicates that the function Pre-flashing is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 7 |
|
|
Off |
During normal operation, indicates that the function Close means Partial opening is disabled. |
|
On |
During normal operation, indicates that the function Close means Partial opening is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 8 |
|
|
Off |
During normal operation, indicates that the function Slave unit is disabled. |
|
On |
During normal operation, indicates that the function Slave unit is enabled. |
|
Flashing |
The function is being programmed. |
Installing a backup battery in a NICE Robus 400 operator
NICE PS124 backup battery is not included as standard with the operator, but it can be ordered separately. It is used in the event of a power outage, when it will power the gate operator. The battery is continuously charged from the mains.
| 1. Pry off the plastic cover over the battery connector | 2. Connect the battery to the connector and place it beside the control unit |
|---|---|
![]() |
![]() |
Manual release of the NICE Robus RB400 operator
![]() |
In the event of a power outage, you will not be able to operate the gate using a remote control. Therefore, the operator can be released using the release key so you can move the gate manually: |
| 1. Slide the release lock cover aside | 2. Insert the release key and turn it clockwise |
|---|---|
![]() |
![]() |
| 3. Pull out the release lever | 4. You can move the gate manually |
![]() |
![]() |
Technical specifications of the NICE Robus RB400 operator
| Model | NICE Robus RB400 |
|---|---|
| Type description | Electromechanical geared motor for automatic operation of sliding gates in residential settings. Supplied with NICE RBA3R10 control unit, but without radio receiver. |
| Gearwheel | Number of teeth: 15 Tooth module: 4 Pitch: 12,6mm Pitch diameter: 60mm |
| Torque [Force] |
12Nm [400N] - required to start the gate leaf moving |
| Rated torque [Rated force] |
6Nm [200N] - required to keep the gate leaf moving |
| Speed | 0,34 m/s |
| Rated speed | 0,18 m/s |
| Limit on consecutive cycles | 100 cycles/day (the control unit limits the number based on the restrictions; see Drive selection) |
| Operating limit | 10 minutes (the control unit limits the time based on the restrictions; see Drive selection) |
| Service life | from 250,000 to 20,000 cycles, depending on the weight and length of the gate leaf, as well as the drive settings |
| Power supply | 230V (+10% -15%) 50/60Hz |
|
Power consumption |
250W [1,1A] |
| Insulation class | 1 - must be earthed |
| Backup power supply | can be purchased separately and installed NICE PS124 backup battery |
| Flashing light output | for two warning lights 12V with a 21W bulb (e.g. NICE Lucy LUCYB, NICE Moonlight MLBT) |
| Indicator output (S.C.A.) | for one 21V, max. 4W bulb (output voltage +50% -30%); can control a small relay |
| BlueBUS output | one output for up to 15 BlueBUS devices |
| STOP input | for normally open, normally closed and 8.2KΩ constant-resistance devices |
| STEP-BY-STEP input (P.P., step-by-step operation) | normally open (closing the contact triggers the command "Step-by-step") |
| OPEN input | normally open (closing the contact triggers the command "Open") |
| CLOSE input | normally open (closing the contact triggers the command "Close") |
| Radio receiver | without a receiver; "SM" connector for receivers NICE SMXI, NICE OXI etc. |
| Antenna input | 52Ω for RG-58 coaxial cable (or similar) |
| Programming functions | 8 on/off functions (Level I programming.) 8 adjustable functions (Level II programming.) |
| Self-diagnostic functions |
gate leaf length measurement (calculation of acceleration and deceleration distances, calculation of the partial-opening point) |
| Operating temperature | -20°C to +50°C |
| Use in saline, acidic and potentially explosive environments | no |
| Protection rating | IP44 |
| Dimensions | 195×330×277 (W×D×H) |
| Weight | 8kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]





































