NICE Road RD400 operator is designed for sliding gates weighing up to 400 kg and a passage width of up to 8 m (recommended maximum length: 5 m). It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

Power supply: The RD400 control unit connects to 230 V AC; the motor runs on 24 V DC. The operator has an integrated radio receiver and supports an optional backup battery NICE PS124.

(Is this operator right for me?)
Compare with other operators:

NICE Road RD400 operator overview

The RD400 uses conventional relay wiring for accessories. Selection depends on the weight and length of the gate leaf, resistance to movement, number of cycles, and accessory compatibility.

NICE Road RD400

NICE Road RD400

  • Max. weight: up to 400 kg
  • Max. gate leaf length: up to 8 m

24 V DC motor; conventional relay inputs; integrated radio receiver.

Optional PS124 battery.

 

This product—the standalone NICE Road RD400 sliding gate operator (our code NICE-RD400-A)—includes:

  • electromechanical NICE Road RD400 operator with a rated capacity of 400 kg and a maximum gate leaf length of 8m, and with a built-in (but removable) control unit RBA4R10 with a built-in radio signal receiver (if you want to control the gate with a remote control, you do not need to purchase a separate receiver).
  • 2 × release keys for manual operation of the operator (required in the event of a power outage)
  • operator installation components, anchors and bracket, stop brackets for the operator limit switch
  • installation manual

Discounted kits containing the operator NICE Road RD400:

Operator kit with accessories » Operator kit with accessories and rack »

 NICE Road RD400 operator kit

Road operator for gates up to 400 kg, remote control, photocells, warning light.
Details and price ».

 NICE Road RD400 operator kit + rack

ROAD operator for gates up to 400 kg, rack, remote control, photocells, warning light.
Details and price ».

Cantilever gate construction kit » Track gate construction kit »
Cantilever sliding gate construction kit

5-bearing roller carriages, 5m Fe C-profile, gate end stop, receiver, guide, operator, rack.
Details and price ».

Track-mounted sliding gate construction kit

Ø90 mm wheels, 3 × 3 m Zn track, bottom stops, guide, operator, rack
Details and price ».

The NICE Road RD400 is a compact electromechanical operator designed to automate sliding gates in residential settings.

The operator is suitable for automating sliding gates weighing up to 400 kg with a gate leaf length of up to 8 m. These values apply under the conditions specified by the manufacturer, including weather conditions, temperature variations, gate rigidity and, above all, ease of gate movement. These conditions are not always achievable or controllable, so we recommend using the NICE Road RD400 operator for gates rated at 60% of these values. See the Choosing an operator section for more information.

The RD400 has dedicated inputs for safety photocells. The number of powered pairs depends on their actual current consumption and wiring; limits and diagrams are provided in the Photocells.

Temperature conditions may limit the operator's available operating time. Details of the operating limits can be found in the section Drive selection.

Adjustable speed, force and pause time for automatic drive closing and more; see Programming.

Diagnostics using warning beacon.

Gear module 4 is compatible with a toothed rack in our range.

Accessories compatible with the NICE Road RD400 drive

We also recommend purchasing compatible optional accessories for the drive, or choosing one of our pre-assembled discounted kits:

What Why Type
Beacon Flashes to indicate gate movement—ideal for exits with limited visibility. Also includes an antenna for greater remote-control range.
  • LED beacon with antenna ELDC

The RD400 manual specifies a FLASH output for one ELDC LED beacon. Choose a different beacon only after checking its voltage, switching method and the output's permitted load.

Photocells They detect obstacles while the gate is closing and stop its movement, preventing it from hitting vehicles or people.
  • Wired relay type – EPM
  • Reflector type, relay – EPMOR
  • Wired relay type EPS
  • Antivandal relay type, wired – EPMA
  • Wired relay type EPL
  • Wired relay type – F210
  • Wired/wireless relay type – FT210
Transmitter For remote control of the gate.
Receiver

For remote control of the gate.

The Road 400 drive already has a built-in receiver. These additional receivers are optional add-ons.

  • NICE IT4WIFI is an optional Wi-Fi interface; the NICE catalogue states that it cannot be used with the PS124 battery. Check the specific control unit configuration before selecting it.
  • Alternatively, a Wi-Fi receiver from another manufacturer. With an external Wi-Fi module, direct control depends on the device's output: the SbS input requires a volt-free NO contact and a separate suitable power supply. Information about the SUPLA app and Zamel (Android/iOS). 

  • GSM receivers: GSM modules – a direct connection to the SbS input requires a volt-free NO contact and a separate suitable power supply; compatibility depends on the specific model.
Antenna

For improved remote-control range.

  •  integrated into the beacon ELDC
  • standalone antenna ABFKIT
Keypad

If you forget your remote, if lots of vehicles or people visit your property and you don't want to give everyone a remote, or if you don't want to open the gate manually.

Key switch

For operating the gate with a key via a switch connected to the operator by cable at any location.

  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder EKSEU
  • flush-mounted, with a standard cylinder EKSI
  • flush-mounted, with a European cylinder EKSIEU
Card readers

Operate the operator by presenting a card or key fob to the card reader.

  • ERA Transponder Reader ETP
Toothing

Essential for automating the operator. 


Without a rack, the operator has nothing to move the gate with.

  • nylon, steel-reinforced, 33 cm LZ-1
  • nylon, steel-reinforced, 1 m LZ-10
  • nylon, steel-reinforced, reverse, 1 m LZ-15
  • steel, 30x8 mm, 1 m LZ-3
  • steel, 30x12 mm, 1 m LZ-5
  • stainless steel, 30x10 mm, 1 m LZ-7
Backup power supply

Backup power source.

Keeps the gate operational in the event of a power failure.

    • backup battery PS124
    • Solar kit SYKCE30 — compatibility with the 230 V AC-powered RD400 version is not confirmed in the manual consulted; verify before purchase.

External Wi-Fi/GSM modules, access keypads and card readers can be connected directly only if their output provides a suitable voltage-free NO contact for the SbS input. Other outputs require a suitable interface and a separate power supply. Also see GSM and Wi-Fi modules.

NICE Road RD400 at a glance

The RD400 has an integrated radio receiver. The board described has four buttons and supports an optional battery NICE PS124. In the event of a power failure, the gate can also be manually released.

NICE RBA4R10 control unit with four buttons

The control unit shown on this product page is the NICE RBA4R10. In the manual for this RD400 generation, NICE lists the RBA4 board; the board shown for sale is marked RBA4R10, which is not explicitly mentioned in this manual. The terminal numbering and procedures below are based on this manual. For the RBA4R10 sold here, verify that these match its own manual or the manufacturer's confirmation. Always check the board and terminal markings before starting work.

Choosing an operator – is the NICE Road RD400 right for my gate?

Once released, the gate must slide smoothly by hand along its entire travel. Sticking, damaged carriages or wheels, and an incorrectly positioned rack must be fixed before adjusting the force. The gate's weight alone does not determine its resistance.

Leaf length Max. cycles/hour Max. consecutive cycles
Up to 5 m 20 15
Over 5 m up to 7 m 16 12
Over 7 m up to 8 m 14 9

Leaf weight Percentage of the cycle count above
Up to 200 kg 100%
Over 200 kg up to 300 kg 85%
Over 300 kg up to 400 kg 70%

One cycle consists of opening and closing. The limits based on length are multiplied by the percentage based on weight; round down to whole cycles. For example, 6 m / 350 kg: 16 × 0.70 = 11 full cycles per hour, with a maximum of 8 consecutive cycles. The limit is also 50 cycles per day and a maximum of 9 minutes of continuous operation. Temperature conditions may further limit the available operating capacity.

NICE Road RD400 operator limits

As a general rule of thumb when choosing an operator, our store recommends a maximum of about 5 m and 250 kg. This is a sales recommendation; assess suitability for the specific gate. The following table distinguishes this recommendation from the manufacturer's limits.

  Maximum Recommended
Leaf length 8 m 5 m
Leaf weight 400 kg 250 kg

Operator maintenance

The operator's service life depends on the gate mechanics, load, environment and maintenance. Carry out maintenance at least every 6 months or after a maximum of 10,000 movements since the last service, whichever comes first.

Installing the NICE Road RD400 operator

On a track-mounted gate, the operator is usually installed low, near ground level. On a cantilever gate, the gear rack is higher, so the operator is raised on anchor elements or a suitable bracket. In either case, adjust the height to suit the rack so its weight does not rest on the pinion and there is 1–2 mm of clearance along the entire travel. A level base, secure anchoring and free manual movement of the gate are essential.

Wiring

Accessory layout according to the original RD400 manual. The number of safety devices is determined by assessing the specific gate.

Layout of the RD400 operator and accessories, diagram 2

Device layout: lowercase letters indicate devices; uppercase letters indicate cable routes.

Accessories list

Item Description / procedure
a / b / c Operator / photocells / photocell posts.
d / e Key switch or keypad / warning beacon.
f / g Rack / safety edges.

Wiring list

Item Description / procedure
A – power supply 3 × 1.5 mm² up to 30 m; for longer supply runs, the manufacturer specifies, for example, 3 × 2.5 mm² and grounding for the automation system.
B – beacon / antenna 2 × 0.5 mm² up to 20 m; separate RG58 up to 20 m, with less than 5 m recommended.
C – EPM photocells TX: 2 × 0.25 mm². RX: power supply and safety contact, e.g. 4 × 0.25 mm² up to 30 m. Cable requirements depend on the photocells and control board used.
D – key switch 2 cables, 2 × 0.5 mm², or 1 cable, 4 × 0.5 mm², up to 50 m; for a single C–NO command, use two wires.
E / F – safety edges 2 × 0.5 mm² up to 30 m. A suitable method of signal transmission is required on the moving gate leaf.

Cables must be suitable for the environment, and their routes must separate mains voltage from control circuits. A relay-type RX requires wires for the safety contact in addition to the power pair.

Installation

See “At what height should I install the operator".

The rack and its end stop

The gate moves by transferring the operator’s pinion torque into linear motion via the rack-and-pinion drive on the operator rack. There are two commonly used types of rack:

Nylon rack for the operator

Nylon rack (optionally with steel reinforcement) – attaches to the gate with self-tapping screws through the mounting holes. Ideal for relatively light, short gates. The steel pinion and nylon rack mesh quietly.

Steel rack for the operator

Steel rack – attaches to the gate by welding on threaded brackets, then screwing the rack into them. Used for longer and heavier gates. The steel pinion running against the steel rack makes operation slightly noisier.

The key requirement is that the operator tooth module is compatible with the rack module. The NICE Road RD400 has a tooth module of 4.

After installing the rack, check the clearance and adjust both limit-switch stops.

  1. Set a clearance of 1–2 mm between the rack and pinion along the entire travel path. The weight of the gate leaf must not rest on the operator.
  2. Manually move the gate leaf towards the open position until it is 2–3 cm from the mechanical stop. Slide the limit-switch bracket until it is activated, then move it at least another 2 cm in the opening direction, as specified by the manufacturer, and secure it.
  3. Set the closed position in the same way, in the opposite direction. The gate’s mechanical stops must remain functional.
  4. Tighten the mounting hardware and check that the gate moves freely along its entire travel path. Only then teach the limit positions.

Checking the 1 to 2 mm clearance between the RD400 rack and pinion

Clearance between the RD400 rack and pinion.

Adjusting the RD400 limit-switch bracket

Distance from the mechanical stop and the additional bracket movement after activation.

Wiring the NICE Road RD400 operator

Before changing wires, replacing fuses, or connecting modules, disconnect the mains and any battery, and verify that the equipment is de-energized. Secure the gate to prevent unintended movement.

Mains power supply

Item Description / procedure
L Live conductor, as indicated on the mains terminal block.
N Neutral conductor.
PE Protective green-and-yellow conductor connected to the protective terminal; the operator is Class I and must be grounded.

This RD400 version is powered by 230 V AC, 50/60 Hz. Never connect the mains supply to the low-voltage terminals 1–8. Select protective devices, isolation, and supply wiring according to the specific installation.

Connecting auxiliary devices

The terminal numbers below are based on the instructions for the RBA4 control board. The board sold is marked RBA4R10; before wiring, check the markings and terminal descriptions on your board and follow its own instructions.

Item Description / procedure
ANTENNA Input for the integrated receiver antenna. Connect the coaxial cable’s center conductor and shielding separately, as indicated by the symbol on the board.
1–2 / SbS Step-by-step control via a voltage-free NO contact, e.g. the C–NO contacts of a switch NICE EKS.
3–4 / STOP NO, NC, or 8.2 kΩ, depending on the wiring. The type is learned during limit-position programming; a change in the learned state triggers a STOP with a brief reverse movement.
1–5 / PHOTO Safety NC contact for the photocells. If triggered while the gate is closing, the gate reverses direction.
4–6 / PHOTOTEST Separate TX power supply for the photocell test, maximum 100 mA. RX remains connected to 1–4.
7–8 / FLASH Output for one warning beacon NICE ELDC; switches at 0.5-second intervals while the gate is moving.
1 (+) / 4 (−) – accessories Terminal 1 = +24 V DC, terminal 4 = 0 V (−/GND). Power supply tolerance −30% / +50%; total current draw of external devices: max. 100 mA.

Multiple NC STOP contacts are connected in series; multiple NO contacts are connected in parallel. Resistive safety edges require the specified cascade wiring with a single 8.2 kΩ termination. Safety inputs must not be bridged as a workaround for a fault. After changing devices, repeat the learning procedure and safety tests.

Drive fuses

DesignationFunctionRating
F1Drive power supply fuseT 1 A / 250 V, slow-blow
F2Control unit fuseT 2 A / 250 V, slow-blow

Actual NICE RBA4R10 four-button board
RBA4R10 board with four buttons. Check the exact designation on your board.
Photographic example showing the position of fuses F1 and F2
The older photo is for reference only. Do not assume the fuse layout is the same on the RBA4R10; follow the markings on your board and its own manual.

F1 protects the drive power supply; F2 protects the control unit.

F1 and F2 fuse locations in the RD400 drive

F1 and F2 fuse locations in the RD400 drive.

Replace a fuse with one of the same type only after identifying the cause of the fault. Do not increase the rating or bypass the fuse.

Standard wiring diagram:

Accessory power supply: terminal 1 is +24 V DC and terminal 4 is 0 V (−/GND), with a maximum total current draw of 100 mA. The SbS (1–2), STOP (3–4) and PHOTO (1–5) inputs are controlled by contacts; therefore, the EKS switch has no +/− terminals of its own. The FLASH output for the warning light uses terminals 7–8; the manufacturer does not specify polarity for them in the diagram shown. During the photocell test, the TX transmitter power supply changes according to the procedure below.

RD400 wiring: ELDC warning light, EPM TX and RX photocells, EKS key switch

Wiring of one pair of EPM relay photocells without photocell testing according to the RBA4 control unit manual. Warning light ELDC has separate FLASH and antenna connections; the EKS switch controls the SbS input via the C–NO contact. A dot indicates an electrical connection; crossing lines without a dot are not connected. Line colors distinguish circuits; they do not indicate wire colors.

DeviceRD400 / RBA4 board
ELDC – warning lightTwo-pin FLASH connector to terminals 7–8. Connect the antenna separately using RG58 coaxial cable to the antenna input: core and shield as marked.
EPM – TX transmitterTX 1 (+) → RD400 1; TX 2 (−) → RD400 4.
EPM – RX receiverRX 1 (+) and 4 (C) → RD400 1; RX 2 (−) → RD400 4; RX 5 (NC) → RD400 5. RX 3 (NO) is left unconnected.
EKS – key switchOne contact: C → RD400 1, NO → RD400 2 (SbS). NC and the second contact are not used in this wiring configuration.
STOP and photocell testSTOP between 3–4 is handled according to the safety devices; the diagram does not specify a universal jumper. Terminal 6 is unused here. For wiring with photocell testing follow the procedure below.

Drive photocells

The example uses NICE EPM: TX is the transmitter, RX the receiver. EPM has TX 1 = +, 2 = − and RX 1 = +, 2 = −, 4 = C, 5 = NC; RX 3 (NO) is not used in the safety circuit. For other photocell types, check their own terminal numbering.

Wiring without the photocell test function

Check the total current draw of the photocells. Output 1–4 supplies a maximum of 100 mA. One pair of EPM photocells draws approximately 55 mA; two pairs without photocell testing would draw approximately 110 mA in total, exceeding this limit. Therefore, connecting the NC contacts in series alone is not enough to connect an additional pair. Plan the power supply for multiple pairs according to their actual current draw and manuals.

Both photocells are permanently powered from terminals 1–4. Connect the receiver's C–NC safety contact between terminals 1 and 5 on the control unit.

Control unit EPM photocells
RD400 1 (+24 V) TX 1 and RX 1; also RX 4 (C).
RD400 4 (GND) TX 2 and RX 2.
RD400 5 (PHOTO) RX 5 (NC).
RX 3 (NO) Not connected.

The numbering shown is according to the RBA4 board manual. After wiring, check the photocell alignment and verify that the gate responds when the beam is interrupted.

Wiring with the photocell test function

During photocell testing, the transmitter power supply is switched: TX 1 (+) goes to terminal 6 (switched PHOTOTEST output) and TX 2 (−) to terminal 4 (0 V/GND). The RX receiver remains permanently powered from terminals 1 (+24 V DC) and 4 (−/GND); its C–NC contact is connected between terminals 1 and 5, as in the wiring without photocell testing. The PHOTOTEST output has a 100 mA limit. The safety circuit response is tested before movement.

Item Meaning / procedure
TX 1 / TX 2 TX 1 (+) → RD400 6 (switched PHOTOTEST output); TX 2 (−) → RD400 4 (0 V/GND). Maximum 100 mA at the PHOTOTEST output.
RX 1 / RX 2 RD400 1 / RD400 4.
RX 4 (C) / RX 5 (NC) RD400 1 / RD400 5.

The operating mode of the connected safety devices is detected during position learning. After changing the wiring, repeat the learning procedure and verify that movement does not start if the test fails.

The available instructions do not clearly confirm the use of the photo test with NICE EPM. For the photo test, the RD400 manual requires synchronisation to be enabled as described in the photocell instructions; however, the EPM instructions describe the SYNC jumper for multiple pairs powered by AC, while the RD400 powers the transmitter with DC. The table lists the terminals according to the RD400 manual; it does not confirm the EPM SYNC setting. Before using this combination, obtain confirmation from NICE or the supplier. RD400 outputs 1–4 have a 100 mA limit.

Selecting the gate travel direction

Determine the direction while standing on the drive side and looking towards the gate. For opening to the left, set the switch to the left; for opening to the right, set it to the right.

RD400 – left-opening configuration and switch position

Left-opening configuration, viewed from the drive side.

RD400 – right-opening configuration and switch position

Right-opening configuration, viewed from the drive side.

Do not change the switch while the gate is moving. Disconnect the power supply before working on the open drive; after changing the direction, check the position learning again.

Assessing the gate leaf length

The learning procedure detects the end positions, the STOP connection and the photo-test mode. Repeat it after changing the stops or safety devices. Keep the movement area clear.

  1. Disengage the drive, move the gate to approximately halfway, then re-engage it mechanically. Check the direction switch.
  2. Switch on the power supply. When idle, the motor is stopped, the green OK LED flashes approximately once per second, and the warning light is off.
  3. Press and hold Close + Stop/Set; release the buttons when movement starts, after approximately 3 seconds.
  4. The first movement must be closing. If the gate opens, stop the learning procedure with the Stop/Set button, disconnect the power supply and check the direction.
  5. Allow the cycle to finish closing → opening → closing. L2 and L3 flash during learning.
  6. When learning is complete, issue an SbS command to open the gate fully, then issue another command to close it fully. During this test cycle, check that the gate slows down approximately 30–50 cm before the limit switches and stops 2–3 cm before the mechanical stops.

If L2 and L3 continue flashing after learning is complete, the learning procedure was unsuccessful. Check the wiring and troubleshooting, resolve the cause and repeat the learning procedure.

Drive programming

The Road drive allows you to program several functions, either by switching a function on or off using Level I programming,, or by setting a parameter value using Level II programming..

The control board has four buttons and four programming LEDs. On this generation, programming mode is entered by holding Set for approximately 3 seconds.

Item Meaning / procedure
Open ▲ Opens the gate; in the menu, moves the selection up.
Stop/Set Stops the gate; holding for approximately 3 seconds opens the menu.
Close ▼ Closes the gate; in the menu, moves the selection down.
Radio Stores and deletes remote controls; indicated by LED L4(R).

RD400 terminal LEDs and four buttons, with LEDs L1 to L4R

Control-board buttons and LEDs. L4(R) belongs to the radio receiver.

Level I programming.

All three Level I functions are OFF by default. A short flash during selection indicates OFF; a long flash indicates ON.

  1. Hold Set for approximately 3 seconds and release it when L1 flashes.
  2. Use Open / Close to select the function LED.
  3. Briefly press Set to toggle OFF / ON. Adjust another function if needed.
  4. Programming ends after 10 seconds without a button press, and the changes are saved.

List of programmable on/off functions:

Item Meaning / procedure
L1 – slowdown distance OFF = short slowdown; ON = long slowdown.
L2 – speed OFF = slow; ON = fast.
L3 – automatic closing OFF = disabled; ON = enabled. The pause time is selected at Level II; the factory setting is 30 s.

Level II programming.

Level II sets a parameter value. The parameter and its value are selected using the same LEDs in two consecutive steps.

  1. Hold Set for approximately 3 seconds and release it when L1 flashes.
  2. Use Open / Close to select parameter L1, L2 or L3.
  3. Hold Set. After approximately 3 seconds, the LED for the current value lights up.
  4. Keep holding Set and use Open / Close to select a new value; then release Set.
  5. The menu closes after 10 seconds without a button press.

List of programmable parameter functions:

Item Meaning / procedure
L1 – motor force L1 low; L2 medium; L3 high (factory setting).
L2 – SbS step sequence L1 open–stop–close–open (factory setting); L2 open–stop–close–stop; L3 condominium mode.
L3 – pause time L1 15 s; L2 30 s (factory setting); L3 60 s. Applies when automatic closing is enabled.

Do not compensate for mechanical resistance in the gate by increasing the force. After changing the force, repeat the relevant measurements and safety tests.

Connecting additional external devices to the drive

Item Meaning / procedure
Power supply for accessories Between 1 (+) and 4 (GND): 24 V DC, tolerance −30% / +50%, maximum total current 100 mA.
Control contact Separate volt-free NO contact on 1–2 (SbS). Do not apply an external voltage to the input.

Special drive functions

Keeping the gate open

If an SbS command is held for longer than 3 seconds, the gate opens regardless of the selected step sequence. This can be used with a suitable timed contact to keep the gate open for a specified period.

Forced movement

If a safety device fails, the manufacturer describes an emergency movement using a control that is held continuously. Use this only with a clear, direct view of the gate, an unobstructed area and no risk to anyone. The fault must be repaired as soon as possible.

  1. Issue a command. If movement does not start because a safety device is blocking it, repeat the command within 3 seconds and hold it.
  2. After approximately 2 seconds, the gate will move only while the command is held.
  3. Release the control to stop the gate immediately. This mode does not replace the repair of safety devices.

Troubleshooting the gate operator

If these steps have not helped, contact NICE operator technical support.

Depending on the nature of the problem

During installation or if the operator malfunctions, you may encounter situations such as:

Item Meaning / action
Remote control does not light up Check its battery.
Remote control lights up, but the gate does not respond Check that the remote control is stored and using the correct protocol, the antenna, and whether the memory is full.
OK LED is off Check the power supply and fuses after safely disconnecting the unit.
Command received, but movement does not start Note the red OK LED flashes or the beacon flash sequence; check PHOTO, STOP, and any active commands.
Movement immediately reverses Check for obstructions, friction, the rack, and the limit switch. Adjust the force only after checking the mechanics and verifying safety again.

Diagnostics using beacon flashes

During normal movement, the beacon flashes at 0.5-second intervals. If a fault occurs, count the flashes in a sequence separated by a pause of approximately one second. The red OK LED indicates the same faults.

Number of flashes Meaning and check
2 Photocell is blocking movement. Check for obstructions, alignment, power supply, and the safety contact.
3 Force limiter activated. Find the cause of excessive friction or check for an obstruction.
4 STOP activated. Check the safety device and wiring.
5 Internal parameter error. Wait at least 30 seconds; if the fault persists, reset the unit and perform a new learning procedure.
6 Duty cycle exceeded. Let the operator rest for a few minutes.
7 Internal electrical fault. Disconnect all power sources for a few seconds; if the fault recurs, check the control board and motor wiring.
8 Another continuous command is already present. Check the button, relay, or timer.
10 Movement time exceeded or no motor power during learning. Check the mechanics and movement time, and make sure the control board is properly seated in its holder.

Diagnostics using LED flashes

This control board has an OK, not BlueBUS. The STOP LED indicates the safety input status; LEDs L1, L2, L3, L4(R) indicate settings and radio status. Their positions are shown in the button diagram.

Horizontal LEDs: OK, STOP

Item Meaning / action
OK – green, once per second Normal operation.
OK – 2 quick green flashes Input state changed or command received.
OK – red flash sequence Fault indicated by the flash code table.
OK – steady green or red Fault state; if it persists after disconnecting the unit and checking it, servicing is required.
OK – off Check the power supply and fuses.
STOP on / off On: input status is OK. Off: STOP activated; check the device and its learned status.

LEDs L1–L4(R) next to the buttons

Item Meaning / action
L1 Off = short deceleration, on = long deceleration.
L2 Off = slow speed, on = fast speed.
L3 Off = automatic closing disabled, on = enabled.
L1 + L2 + L3 flashing Position learning is required; follow the relevant procedure during programming.
L4(R) on An unregistered radio code was received during normal operation.
L4(R) flashing Remote controls are being stored or deleted.

Manual release of the NICE Road RD400 operator

In the event of a power failure or malfunction, the RD400 can be released using the supplied key so the gate can be operated by hand. First, prevent unintended movement and disconnect the power sources. If the gate leaf moves by itself or sticks after release, it requires repair.

Manual release and re-engagement of the RD400

The left side of the image shows how to release the RD400; the right side shows how to re-engage it.

  1. Open the lock cover, insert and turn the key, then flip out the release handle as shown.
  2. Move the gate slowly by hand, keeping it under control.
  3. To re-engage the operator, fold the handle back, turn and remove the key, then close the cover. Check that the mechanism has engaged before operating it automatically.

 Technical specifications of the NICE Road RD400 operator

Item Meaning / action
Use / limits For residential sliding gates, up to 400 kg and 8 m, depending on the duty cycle.
Motor / power supply Electromechanical operator with built-in control unit; RD400 mains supply: 230 V AC, 50/60 Hz. The RD400/V1 is a different voltage version.
Max. power consumption / current 210 W / 1.1 A.
Torque Starting torque: 12 Nm (400 N); rated torque: 5 Nm (167 N).
Speed No-load: 0.13 or 0.25 m/s; at rated torque: 0.16 m/s.
Gearing Z15, module 4, pitch 12.5 mm, pitch diameter 60 mm.
Operation Max. 50 cycles per day, continuous operation max. 9 min; further limits apply depending on length and weight.
Fuses / protection F1 T 1 A / 250 V; F2 T 2 A / 250 V; Class I, protective earthing.
Beacon / battery One NICE ELDC; optional NICE PS124.
Functions 3 ON/OFF functions and 3 adjustable parameters. Learning STOP and positions.
Environment −20 to +55 °C; IP44.
Dimensions / weight 330 × 195 × 277 mm; 8 kg.

Technical specifications of the built-in radio receiver in the NICE Road RD400 drive

Item Meaning / procedure
Receiver Integrated, 4 commands, 433.92 MHz.
Protocols FloR, O-Code, Smilo. The first remote control stored determines the family of subsequent remotes.
Memory With the RBA4 board, up to 100 remote controls can be stored in Mode I; confirm the capacity of the RBA4R10 from its own manual.
Antenna / sensitivity 52 Ω, RG58 or equivalent cable; sensitivity better than 0.5 µV.
Range The manufacturer specifies 100–150 m; range is affected by obstacles, interference and antenna location.
Temperature −20 to +55 °C.

Storing remote controls

This procedure is for the integrated receiver of the RBA4 board with four-button generation. Before using it with the RBA4R10, confirm that the buttons and modes correspond. Choose a remote control with a supported protocol, such as NICE ON2E or NICE FLO2RE, depending on the family in use. Pairing does not require erasing the gate travel limits.

Mode I – entire remote control

  1. Hold Radio for at least 5 s, then release it when LED L4(R) lights up.
  2. Within 10 s, hold the first button on the remote control for at least 5 s, then release it.
  3. Three flashes of L4(R) confirm that it has been stored. The mode ends after 10 s if no further control is stored.

T1 = step-by-step, T2 = pedestrian opening, T3 = open, T4 = close; a two-button remote control has only T1 and T2.

Mode II – one button

  1. Briefly press Radio once for step-by-step, twice for pedestrian opening, three times to open or four times to close.
  2. Check that L4(R) flashes the corresponding number of times.
  3. Within 10 s, hold the desired button on the remote control for at least 3 s; three flashes confirm that it has been stored.

Compare other receivers and procedures in our NICE remote control pairing guide. If the remote control cannot be stored, also check whether the radio memory is locked.

Control unit reset

Reset is for deliberately erasing settings, not a required first step. With the motor stopped, hold Open + Close for approximately 3 s. When all LEDs light up, release the buttons. When the process is complete, L1, L2 and L3 flash. Position learning, settings and safety tests must be repeated. This procedure does not erase stored remote controls.

Backup battery and service interface

The optional battery designed for this generation of the RD400 is the NICE PS124 with a capacity of 1.2 Ah and integrated charging. Connect it only after installation and programming are complete, with the mains disconnected. Once connected, the drive is powered even when the mains supply is off. Runtime depends on the drive load and battery condition.

Service programmer NICE OVIEW connects via NICE IBT4N to BusT4. Connect the interface with the power supplies disconnected.

Testing, handover and maintenance

  • Check opening, closing, stopping, slow-down and both limit switches.
  • Test every pair of photocells, every STOP device and the photo test, if used.
  • Check the forces and carry out the measurements required for the specific gate; excessive force must not be used to compensate for a mechanical fault.
  • Check the manual release, covers, protective devices and labels. Provide the user with operating instructions and a maintenance schedule.

Carry out maintenance at least every 6 months or after no more than 10,000 movements since the last service. The user must keep the area and photocells clean; stop using the automation if unusual noise or jerky movement occurs. When cleaning the track, disconnect any backup battery as well. Watch the gate from a safe distance while it is moving. Pass through only when the gate is fully open and stationary. Children must not operate the gate or play nearby.

Back to top

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Road RD400 - standalone operator for sliding gates (A)

Product: NICE Road RD400 - standalone operator for sliding gates (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.