NICE EPMOB - Era Photocell Medium - photocells with BlueBUS connection, (1 pair), adjustable
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
Description of NICE EPMOB - Era Photocell Medium - photocells with BlueBUS connection, (1 pair), adjustable
Fully compatible successor NICE MOFB photocells.
Outdoor safety photocells NICE EPMOB (technical specifications) are installed opposite each other across the gate opening, or at any point where there is a risk of the gate hitting an obstacle. They create an infrared beam along the optical axis; when it is interrupted, they send a signal to the gate to stop it. They can only be used with devices that support BlueBUS.
Installing NICE EPMOB photocells
| 1. Open the photocell | 1a. Remove the transparent cover |
|---|---|
![]() |
![]() |
| 2. Remove the electronics as shown by the arrows | 3. Punch out the holes needed for installation |
![]() |
![]() |
| 4. Punch out the required cable entry | 5. Refer to the example layoutsto see how to position the photocells at the installation site. |
![]() |
|
| 6. Depending on the location of the photocells at the installation site, set the addressing jumpers according to the table. | 7. Position the photocells directly opposite each other |
![]() |
![]() |
| 8. Mount the photocell housings on a wall or post | 9. Connect the photocell wiring (make sure to disconnect the power supply first) |
![]() |
![]() |
| 10. Install the connected photocell electronics in the housings and restore the power supply. Run the connected-device detection phase on the drive control unit. | 11. Test the photocells. If you encounter a problem, follow the troubleshooting guide |
![]() |
![]() |
| 12. Fit the cover onto the photocell and secure it with screws. Remember the insulating rubber seal | 13. Fit the transparent cover. Remember the insulating rubber seal. |
![]() |
![]() |
Connecting multiple pairs of photocells NICE EPMOB to the data network NICE BlueBUS
Position the photocells around the gate or gates according to the example layouts for the complete wiring diagram and set the jumpers according to the jumper table for the photocells NICE EPMOB gate drive. To prevent interference between pairs positioned close to one another, be sure to follow these example layouts, and maintain the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you need the photocells to function as gate openers (see FA1 and FA2 in the example layouts), i.e. when you drive a vehicle between their optical axes, so that they open the gate, you need to interrupt connection A on the transmitter TX and receiver RX, see figure:
Examples of complete wiring configurations for multiple pairs of NICE photocells EPMOB drive
1. Single-leaf sliding gate
2. Two synchronized sliding gates facing each other
3. Swing gate
4. Sectional garage door
5. Up-and-over garage door
NICE photocell jumper table EPMOB gate drive
![]() |
Connecting multiple pairs of photocells to the system BlueBUS is done by setting different jumper combinations; each connected pair must have a unique jumper configuration. Make sure that no two pairs in the same BlueBUS data network have the same configuration. For each pair of photocells, set the jumper to the same position on both the transmitter (TX) and receiver (RX). If the configuration uses only one or no jumper, keep any unused jumpers for future use. |
| Photocell pair designation | Jumper configuration |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
| FOTO 3 | ![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If a photocell needs to be replaced for any reason, simply set it to the same jumper configuration as the original one; there is no need to run the device recognition phase.
Testing photocell operation and troubleshooting NICE photocell wiring EPMOB
![]() |
After the drive has recognized the devices, check that the LED on both the transmitter (TX) and receiver (RX) is flashing. The LED may flash as follows: |
| LED "L" | Status | What to do |
|---|---|---|
| Off | The photocell is not powered or is faulty. | Check that the voltage at the photocell inputs is approximately 8-12V. If the voltage is correct, the photocells are probably faulty. |
| 3 quick flashes followed by a one-second pause | The device has not been recognized by the drive control unit. | Repeat the recognition phase on the control unit. Make sure that each pair of photocells has been assigned a unique address using jumpers . |
| Very slow flashing | The transmitter (TX) is transmitting regularly The receiver (RX) is receiving an excellent signal |
Normal operation |
| Slow flashing | The receiver (RX) is receiving a good signal | Normal operation |
| Fast flashing | The receiver (RX) is receiving a weak signal | Normal operation. However, ideally, check the alignment of the transmitter (TX) and receiver (RX), and make sure the covers are clean. |
| Very fast flashing | The receiver (RX) is receiving a very weak signal | Operation is still normal, but borderline. Ideally, check the alignment of the transmitter (TX) and receiver (RX), and make sure the covers are clean. |
| On | The receiver (RX) is not receiving any signal | Make sure the LED on the TX is flashing slowly. Check that there is no obstruction in the optical path between the transmitter (TX) and receiver (RX). Check the alignment of the TX and RX. |
NICE photocell technical specifications EPMOB
| Product type | Detector for automatic swing gates, sliding gates and garage doors, Type D according to EN 12453, consisting of a transmitter TX and receiver RX. |
|---|---|
| Technology | Direct optical TX-RX interpolation with a modulated infrared beam. |
| Power supply/Output | The device may only be connected to a data network that supports the NICE BlueBUS, from which it receives electrical power and sends an output signal. |
| Absorption | 1 BlueBUS unit |
| Detection capability | Opaque objects larger than 50 mm passing through the optical axis between the TX transmitter and RX receiver at speeds below 1.6 m/s. |
| TX transmitter beam angle | 20° +-25% |
| RX receiver acceptance angle | 8° +-25% |
| Normal range (usable) | 15 m (may be halved in adverse weather conditions, e.g. fog, rain, dust, etc.) |
| Maximum range | 30 m |
| Addressing | 7 pairs with a safety function and 2 pairs with an "Open" command function |
| Use in acidic or saline environments, or in environments with an increased risk of explosion | No |
| Installation | Vertical wall/post mounting, with the photocell direction adjustable in all directions by up to 30°. The maximum cable length for one branch of the BlueBUS system is 50 m. |
| Protection rating | IP44 |
| Operating temperature | -20°C to 55°C |
| Dimensions (W×H×D) | 50x80x28.5mm (one photocell) |
| Weight | 143g (both photocells combined) |
Photocell wiring NICE EPMOB with drive NICE Robus 400, 600, 1000
Inside the photocells NICE EPMOB for gate operators
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]