NICE Robus RB1000 - standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€574.88 including VAT
| Weight |
|---|
| 14 kg |
Description of NICE Robus RB1000 - standalone operator for sliding gates (A)
NICE Robus RB1000 gate operator is designed for sliding gates with a weight of up to 1000 kg and a passage width of up to 12 m. It has an electromechanical limit switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».
(Is this operator right for me?)
Compare with other operators:
| « Lower-powered operator | Alternative operator | More powerful operator » |
|---|---|---|
|
|
![]()
|
|
This product—the standalone NICE Robus RB1000 sliding gate operator (our code NICE-RB1000-A)—includes:
- electromechanical NICE Robus RB1000 operator with a capacity of 1000 kg and a maximum gate leaf length of 12m, with a built-in (but removable) control unit RBA3R10 without radio receiver (OXI).
- 2 × release key for manual operation of the operator (required in the event of a power failure)
- operator mounting components, anchors and bracket, limit switch stops for the operator
- installation manual
Discounted kits containing a operator NICE Robus RB1000:
| Operator kit with accessories » | Operator kit with accessories and rack » |
|---|---|
|
Robus operator for gates up to 1000 kg, remote control, photocells, warning light, key switch. |
ROBUS operator for gates up to 1000 kg, rack, remote control, photocells, warning light, key switch. |
The operator is compact, safe and practical, ideal for both residential and commercial use. Impact-resistant housing, aluminium alloy body with an epoxy coating.
The operator is suitable for automating sliding gates weighing up to 1000 kg, with a gate leaf length of up to 12 m. These values apply under the conditions specified by the manufacturer, including weather conditions, temperature variations, gate rigidity and, above all, smooth gate movement. These conditions cannot always be achieved or controlled, so we recommend using the NICE Robus RB1000 operator ideally for gates operating at 80% of these limits. See the Choosing an operator chapter for more information.
Very user- friendly technology BlueBUS allows you to power and control up to 7 pairs of photocells using a two-core cable.
Temperature sensor adjusts the operator's pulling force according to the climatic conditions. The operator also includes a thermal fuse.
Adjustable speed,, force and pause time for automatic closing of the operator and much more; see Programming.
Diagnostics using warning light.
Gear module 4 is compatible with the rack in our range.
Robus 1000 drive function "The slave unit" ensures automatic synchronisation of two motors. This means that it is possible to automate two sliding gates moving towards each other.
Drive NICE Robus RB1000 is an electromechanical drive suitable for the climatic conditions in Slovakia and meets all European safety standards.
Accessories compatible with the NICE Robus RB1000 drive
We also recommend purchasing compatible optional accessories for the drive, or choosing one of the pre-assembled discounted sets:
| What | Why | Type |
|---|---|---|
| Warning light | Flashes to indicate gate movement – ideal for exits with limited visibility. Also includes an antenna for greater remote-control range. |
Alternatively, all warning lights with a 12V-24V power supply from other manufacturers. |
| Photoelectric cells | They detect obstacles while closing and stop the gate – preventing it from hitting cars or people. | |
| Transmitter | For remote control of the gate. | |
| Receiver |
For remote control of the gate. |
|
| Antenna |
For greater remote-control range. |
|
| Keypad |
If you forget your remote control, or if many vehicles or people need access and you don’t want to give everyone a remote or open the gate manually. |
|
| Key switch |
Control the gate with a key using a switch connected to the drive by cable from any location. |
|
| Card readers |
Operate the drive by presenting a card or key fob to the card reader. |
|
| Drive rack |
Required for the drive automation itself.
|
|
| Backup power supply | Keeps the gate operating during a power outage. |
Manuals and documents to download
NICE Robus RB1000 at a glance
NICE Robus is a family irreversible electromechanical gear drives for sliding gates. They are supplied with a built-in (but removable) NICE RBA3R10 control unit with an SM connector for external receivers radio signal NICE SMXI, or NICE OXI. Electrical connections for external devices (photocells, warning light, etc.) have been simplified in the NICE Robus sliding gate drive family through the use of BlueBUS, which allows several devices to be connected to a shared terminal using just one two-core cable, with no need to observe polarity. Automatic operation depends on the power supply, but if the power fails, the gearmotor can of course be released using a special release key so the gate can be operated manually. It is also possible to purchase an optional NICE PS124 backup battery, which allows the gate drive to keep operating during a power outage.
Choosing a drive – is the NICE Robus RB1000 suitable for my gate?
Every gate has its own size (and therefore a lever arm) and weight (and therefore a gravitational force acting on the lever arm) and every drive has its limits. The NICE Robus RB1000 drive is suitable for the following gate leaf lengths and gate weights:
|
Number of cycles/hour Number of consecutive cycles |
Gate leaf weight | |||||||
| Up to 200kg | 200- -400kg |
400- -500kg |
500- -600kg |
600- -800kg |
800- -900kg |
900- -1000kg |
||
|---|---|---|---|---|---|---|---|---|
|
W
l |
Up to 4m |
50 |
45 |
37 19 |
30 |
25 12 |
22 11 |
20 10 |
| 4-6m | 33 16 |
29 14 |
24 12 |
20 10 |
16 8 |
15 7 |
13 |
|
| 6-8m | 25 12 |
22 11 |
19 9 |
15 7 |
13 6 |
11 5 |
10 4 |
|
| 8-10m | 20 10 |
18 9 |
15 7 |
12 6 |
10 5 |
9 4 |
8 3 |
|
| 10-12m | 16 8 |
14 7 |
12 6 |
10 5 |
8 4 |
7 3 |
6 2 |
|
In principle, the gate leaf length determines the maximum number of cycles per hour and consecutive cycles, i.e. it specifies how long the drive can operate. A greater gate weight further reduces the number of these cycles by a percentage, due to the increased load on the drive, and also determines the maximum permitted speed for the given load. The drive is equipped with a device (thermal protector), which measures both the motor temperature and the ambient temperature, and reduces the number of possible cycles accordingly.
NICE Robus RB1000 drive limits
The values shown are those recommended by the manufacturer, NICE. Based on our experience, we recommend allowing a reserve of approx. 80% of the values shown:
| Maximum | Recommended | |
|---|---|---|
| Gate leaf length | 12 m | 9.5 m |
| Gate leaf weight | 1000 kg | 800 kg |
Using the drive at its maximum capacity reduces its service life — see the approximate calculation of the drive's service life based on stress factors:
NICE Robus RB1000 drive service life
In the following table, add the stress indexes for the gate leaf weight and length, and add the indexes for other factors if applicable. Then use the graph to determine the drive's service life, expressed as a number of cycles.
Example: I have a gate with a clear opening of 4.5 m and a structure weight, including infill, of up to 200 kg (a standard gate). I calculate the gate leaf length index as approx. 15 + the gate weight index 10 +, to be on the safe side, I add the low-temperature index 10 because we have harsher winters, giving me a total index of 35. The graph shows that the drive's service life is approximately 120,000 cycles. At 10 movements per day, this corresponds to a service life of approximately 32 years.
| Properties of the entire automation system | Index | Service life graph |
|---|---|---|
| Gate leaf weight |
The recommended maximum total index is up to 75%. (i.e. 40,000 cycles, which at normal use of 10 cycles/day is 10 years)
|
|
| Up to 200 kg | 5 | |
| 200–400 kg | 10 | |
| 400–600 kg | 20 | |
| 600–700 kg | 30 | |
| 700–800 kg | 40 | |
| 800–900 kg | 50 | |
| 900–1000 kg | 60 | |
| Gate leaf length | ||
| Up to 4 m | 5 | |
| 4–6 m | 10 | |
| 6–8 m | 20 | |
| 8–10 m | 35 | |
| 10–12 m | 50 | |
| Other factors (if the probability of their occurrence is greater than 10%) | ||
| Ambient temperature above 40°C, below 0°C, or humidity above 80% | 10 | |
| Dusty environment | 15 | |
| Saline environment | 20 | |
| Photocell activation | 10 | |
| STOP input activation | 20 | |
| Speed higher than "L4 - Fast" | 15 | |
| Peak function active | 20 | |
Installing the NICE Robus RB1000 operator
The installation method of the operator is different for a track-mounted sliding gate and a cantilever sliding gate . For a track-mounted gate, the operator is generally installed at ground level, whereas for a cantilever gate, it is necessary to operators raise it using, for example, threaded rods (Ø8 threaded rod), a custom-made bracket, a raised concrete base, etc. The key factor is the height of the rack, so that it meshes correctly with the operator's pinion. See The rack and its end stop.
Wiring
A typical (optional) operator and accessory wiring layout looks as follows:
List of accessories
|
|
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| A. Power supply | 3×1.5mm2 | 30m; for longer runs, 3×2.5mm2 + earth |
| B. Warning light with antenna |
2×0.5mm2 |
20m 20m (recommended: less than 5m) |
| C. Photocells | 2×0.5mm2 | 30m; over 30m, 2×1mm2 |
| D. Key switch | 4×0.5mm2 | 50m (or 2 pcs. 2×0.5mm2) |
| E. Static safety edges | 2×0.5mm2 | 30m |
| F. Moving safety edges | 2×0.5mm2 | 30m |
Installation
See "What height should I install the gate operator at".
The rack and its stop
The gate moves by transferring the rotary torque of the operator's pinion into linear motion via the rack-and-pinion drive on the operator rack. The two most commonly used types of rack are:
|
Nylon rack (optionally with steel reinforcement) – attached to the gate with self-tapping screws through the mounting holes. Ideal for relatively light and short gates. The friction between the steel pinion and nylon rack makes operation quiet. |
|
|
Steel rack – attached to the gate by welding threaded brackets to it, then screwing the rack into them. Used for longer and heavier gates. Friction between the steel pinion and steel rack makes operation slightly noisier. |
The key requirement is that the operator pinion module is compatible with the rack module. Operator NICE Robus RB1000 has a tooth module of 4.
The operator detects the end positions when opening and closing using limit stops mounted on the rack:
Wiring the NICE Robus RB1000 operator
Before connecting, disconnecting or changing the wiring of the operator or accessories, remember to disconnect the power supply, either at the circuit breaker, by removing the power fuse, or by disconnecting the backup battery.
...to the mains
![]() |
For basic operation, you only need to connect the operator to the power supply.
The wiring is simple:
|
...accessories
NICE RBA3R10 control unit operator NICE Robus RB1000 provides the following inputs and outputs for accessories:
| Input/output | Description |
|---|---|
| Output for up to two 12V warning lights NICE LUCYB (or NICE MLBT) with one 12V 21W bulb | |
| S.C.A. (Indicator) |
Indicator output (24V 4W). Its behavior can be configured using Level II programming, setting L4; see Level II programming, L4 – Indicator output. |
| Input for parallel connection of compatible devices using BlueBUS using a two-core cable that carries both the power supply and the communication signal. | |
| STOP (Stop) |
Input for devices that stop gate movement. The following devices can be connected:
|
| Input for devices that step through the gate movement (see Step-by-step gate movement). Normally open (NO) devices can be connected. | |
| OPEN (Open) |
Input for devices that control the gate opening movement (see Gate opening). Normally open (NO) devices can be connected. |
| CLOSE (Close) |
Input for devices that control the gate opening movement (see Gate closing). Normally open (NO) devices can be connected. |
| AERIAL (Antenna) |
input for the radio receiver antenna. The antenna is usually built into the warning light, for example: NICE LUCYB, NICE MLBT, or a separate external antenna can be used NICE ABFKIT. |
Operator fuses
|
In the operator there are two fuses:
|
||||||||||||
Standard wiring diagram:
Operator photocells
Very user-friendly BlueBUS technology allows powering and controlling up to 7 pairs of photocells using a two-core cable.
Connecting multiple pairs of photocells NICE EPMB to the data network NICE BlueBUS
Position the photocells around the gate or doors according to the example layouts for the complete wiring and set the jumpers according to the jumper table for the NICE EPMB photocells gate operator. To prevent interference between pairs installed close to one another, be sure to follow these example layouts, and observe the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you want the photocells to work as gate openers (see FA1 and FA2 in the example layouts), i.e. when a vehicle passes between their optical axes, causing the gate to open, you need to break connection A on both the transmitter TX and receiver RX, see image:
Example photocell installation layout
NICE photocell jumper table EPMB gate operator
![]() |
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations; each connected pair must have a unique jumper combination. Make sure that no two pairs in the same BlueBUS data network have the same combination. For each pair of photocells, set the jumper on both the transmitter TX and receiver RX to the same value. If the jumper type uses only one or no jumper, always keep any unused jumpers for future use. |
| Photocell pair designation | Jumper setting combination |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| PHOTO 2 II | ![]() |
| PHOTO 3 | ![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If a photocell needs to be replaced for any reason, simply set it to the same jumper as the original one; there is no need to perform the device recognition procedure.
Radio signal receiver for operators
![]() |
NICE Robus RB1000 operator is supplied with NICE RBA3R10 control unit, which has an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for detecting commands sent from the remote controls, and is therefore required for operating the sliding gate remotely remote control. |
Selecting the gate opening direction
The sliding gate’s opening direction must be selected based on the position of the operator relative to the sliding gate leaf. Look at the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
The switch is located on the right-hand side of the RBA3R10 control unit in the middle.
Recognizing connected operator devices
After connecting, disconnecting, or changing the wiring of any accessories on the BlueBUS inputs and STOP the accessory recognition procedure. The operator will alert you when this procedure is required by flashing LEDs L1 and L2.
![]() |
|
Recognizing the gate leaf length
For the gate to operate correctly (in particular, to calculate acceleration and deceleration distances and partial opening), the operator must determine the length of the gate leaf itself. During this procedure, the operator moves the gate from one stop to the other and determines its length using a switch.
![]() |
|
Programming the operator
The Robus operator lets you program various functions, such as switching a function on or off by programming Level I., or by setting the default parameter by programming Level II.
RBA3R10 control unit has three buttons for operating and programming the drive:
![]() |
Button | Function |
|---|---|---|
| Open | The button lets you send the drive an open-gate command. It is also used during programming to move the value of the selected parameter up. | |
| Stop/Set | The button lets you send the drive a stop-gate command. Press and hold it for 5 seconds to enter Level I programming. Press and hold it again to enter Level II programming. for the current LED. | |
| Close | The button lets you send the drive a close-gate command. It is also used during programming to move the value of the selected parameter down. |
Programming – Level I
At Level I, programming enables/disables the selected function. When a function is enabled, its corresponding LED on the control unit lights up. All functions are disabled by default.
To enter Level I programming, press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Then use the “Open” and “Close” buttons to move the current LED up or down. You have 10 seconds for each action; otherwise, the drive will exit programming mode. When the flashing LED reaches the function LED you want to enable/disable, press the “Stop/Set” button once to make it flash faster (function enabled) or slower (function disabled), then leave it as is and allow the drive to exit programming mode within 10 seconds. If the procedure was successful, the corresponding LED for the enabled function will remain lit.
List of programmable functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After a set time (configured under “Level II programming – Pause duration”), the gate will start closing automatically after it opens. If this function is disabled, the gate can only be operated by a command from a gate remote control or similar. |
| L2 | Close after photocells are cleared |
This function keeps the gate open only for as long as necessary for a vehicle to pass through. Once the photocells are clear (the vehicle has passed through), the gate will start closing automatically after 5 seconds. This function behaves in two different ways depending on whether automatic closing (see the previous function) is enabled. Automatic closing enabled – the gate stops when the photocells are cleared and starts closing after 5 seconds. This means it may not open all the way. |
| L3 | Always close | After a power failure, the gate either stays in its current position (if this function is disabled) or closes (if the function is enabled). |
| L4 | Standby mode | This function reduces power consumption to a minimum. It is particularly useful when powered by a backup battery (e.g. NICE PS124). When this function is enabled, the control unit switches off one minute after the gate’s last movement BlueBUS input (and therefore all devices connected to it), along with all LEDs except the BlueBUS LED, which will flash slowly. In this state, if a command is received, control unit will restart first and only then carry out the command. |
| L5 | Boost | Disables the drive’s soft start at the beginning of a manoeuvre, making it start immediately at full force.. Suitable when friction is high or when the drive needs to break through snow and ice, so this function is especially useful in winter. On the other hand, it reduces the service life of the drive. |
| L6 | Pre-flashing | After receiving a gate movement command, the warning light flashes for three seconds to warn people nearby, then the requested movement starts. |
| L7 | Close means partial opening | A close will always start a gate manoeuvre. |
| L8 | Slave unit | Enabling this function is useful when installing two automated sliding gates facing each other – one drive is the master of the other. The slave drive has this function enabled and is synchronized with the master drive via the BlueBUS input. See also: Robus in slave mode. |
Programming – Level II
At level II, programming sets the values for the specified functions (these functions differ from level I.).
Forget about level I programming. To enter level II programming, press and hold the “Stop/Set” button for approx. 5 seconds, until LED L1. Then use the “Open” and “Close” buttons to move the currently lit LED up or down, respectively. You have 10 seconds for each action; otherwise, the drive will exit programming mode. When the flashing LED reaches the function LED whose parameter you want to set, press and hold the “Stop/Set” button to enter the setting for that LED. The LED that remains lit (while you continue holding “Stop/Set”) indicates the current parameter value. You can change this value up or down using the “Open” or "Close” buttons (continue holding the “Stop/Set” button); then release “Stop/Set” and wait for the drive to exit programming mode, which it will do within 10 seconds. To check that everything went as expected, repeat the procedure without changing the parameter value.
List of programmable functions:
|
Input LED — Name |
Setting LED — Value |
|---|---|
| L1 — Pause duration If the “Automatic closing” option is enabled in level I programming, |
L1 — 5 seconds L2 — 15 seconds L3 — 30 seconds L4 — 45 seconds L5 — 60 seconds L6 — 80 seconds L7 — 120 seconds L8 — 180 seconds |
|
Sets the sequence of gate movements triggered by repeatedly pressing, for example, the button on the gate remote, or by activating the STEP-BY-STEP input (also known as P.P., or Step-by-step). |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium after two Stops L6 — Step-by-step after two presses: partial opening L7 — Hold-to-run L8 — Semi-automatic opening, hold-to-run closing |
|
Sets the gate speed during normal operation (excluding acceleration and deceleration). |
L1 — Very slow (30%) L2 — Slow (45%) L3 — Medium (55%) L4 — Fast (70%) L5 — Very fast (85%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
|
Sets when a signal should be sent to the S.C.A. output (24 V, −30%/+50%, maximum power 4 W) |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
|
The motor force control system detects the gate weight. This system also monitors the ambient temperature and automatically adjusts the motor force, for example increasing it at very low temperatures. |
L1 — Super-light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Moderately heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Super-heavy gate |
|
Sets the travel distance for partial opening. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.5 m L8 — 4.0 m |
|
Sets the number of gate manoeuvres after which the drive will indicate that maintenance is required. |
L1 — Automatic (the drive calculates this automatically based on the difficulty of the manoeuvres) L2 — 1000 × L3 — 2000 × L4 — 4000 × L5 — 7000 × L6 — 10000 × L7 — 15000 × L8 — 20000 × |
|
Plays the type of up to the last 8 error messages. |
L1 — Result of manoeuvre 1 L2 — Result of manoeuvre 2 L3 — Result of manoeuvre 3 L4 — Result of manoeuvre 4 L5 — Result of manoeuvre 5 L6 — Result of manoeuvre 6 L7 — Result of manoeuvre 7 L8 — Result of manoeuvre 8 |
Automating two opposing sliding gates using two NICE Robus RB1000 drives
If you need to automate two sliding gates facing each other, drives Robus drives can be configured to operate in slave mode. The operating principle is that one drive is the master and sends commands to the other, the slave.. All Robus drives are set as master units at the factory, so this parameter must be configured on the slave drive in Level I programming. using function L8 – Slave unit.
Restrictions for connecting master and slave units
- A gate operated by a slave unit can only be opened fully (it cannot be opened in any other way; there is no option for partial opening).
- All devices (photocells, receiver, etc.) must be connected to the master unit. Only the following may be connected to the slave unit: warning light, S.C.A. output indicator, devices connected to the STOP input and P.P. (also called STEP-BY-STEP, or Step-by-step), OPEN inputs and CLOSE are ignored.
- If you want to use a backup battery (NICE PS124), each drive must have its own.
- All functions programmed on the slave unit are ignored, except for functions programmed under:
| Level I programming. | Level II programming. |
|---|---|
| L4 – Standby mode | L3 – Motor speed |
| L5 – Peak | L4 – Output indicator |
| L8 – Slave unit | L5 – Motor force |
| L8 – Error log |
Installation procedure for two Robus drives in slave mode
1. Install the gates and drives, then set the opening directions as shown in:
2. Connect the drives as shown in the diagram (observe the polarity of the BlueBUS wiring connection between the drives):
3. Connect the power supply to both drives
4. In Level II programming, set the parameter on the slave unit L8 – Slave unit
5. Carry out the connected-device recognition procedure on the slave unit
6. Carry out the connected devices assessment phase on the master control unit
7. Perform the gate leaf length assessment phase on the master control unit
Connecting additional external devices to the drive
![]() |
If you need to connect additional devices to the drive that require an external power supply (e.g. indicator lights, key switch, magnetic cards, etc.), connect the device as shown in the illustration. The supplied voltage is 24Vdc -30% to +50%, with a maximum current of 100mA. |
Special drive functions
Gate held open
If the command to the STEP-BY-STEP input (also called P.P. or Step-by-Step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is held. This function is useful when combined with a timer.
Forced operation
If a safety device fails, or, for example, an obstacle that cannot be removed gets into the beam of the photocells and the gate will not move for safety reasons, you can activate the “Hold-to-run” mode, either permanently in Level II programming under the setting L2 - Step-by-step mode to the value L7 - Hold-to-run, or temporarily:
- Send a command to the gate using (a remote control, a key switch etc.)
- If there is a problem, the gate will not move and the warning light will probably indicate an error.
- Therefore, within 3 seconds of the previous command, send the command again and keep holding it.
- The gate will move while you hold the command and stop as soon as you release it.
Maintenance notification
In Level II programming item L7 - Maintenance reminder you can set the number of cycles after which the drive should signal that maintenance (an inspection) is required. The drive signals this using the warning light (or on the S.C.A. output, if configured in Level II programming under item L4 - Output indicator level L7 - Maintenance) as follows:
| Number of cycles | Warning light signal | S.C.A. output indicator signal |
|---|---|---|
| less than 80% of the limit | Normal operation; flashes at half-second intervals. | “Lights up” for 2 seconds after opening begins. |
| 80-100% of the limit | Lights up for 2s after the manoeuvre starts, then operates normally. | Flashes during the manoeuvre. |
| over 100% of the limit | Lights up for 2s after the manoeuvre starts, then operates normally, and lights up for 2s after the manoeuvre ends. | Flashes continuously. |
For instructions on clearing the maintenance notification and checking the current number of manoeuvres against the limit, see section 7.4.3 of the manual.
Troubleshooting the drive
If anything is unclear or you have any other problem, feel free to contact our technical support for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
The gate does not respond to the remote control, and the LED on the remote control does not light up. |
Check whether the batteries in the remote control are working; if not, replace them. See the manual for the specific remote control for instructions. |
|
The gate does not respond to the remote control, but the LED on the remote control lights up. |
Check whether the remote control has been programmed receiver is working properly, or try remote control programming it again. |
|
The gate does not move and the BlueBUS LED does not flash.
|
Check whether the drive is receiving 230V power. If it is, test both fuses and, if necessary, replace them with new fuses of the same rating. |
|
The gate does not move and the warning light does not flash. |
Check whether the drive has registered the command. When a command is sent using a remote control the BlueBUS LED should flash rapidly twice. If the command is sent by another device through the STEP-BY-STEP input (P.P.), the corresponding STEP-BY-STEP LED. |
|
The gate does not move and the warning light flashes several times. |
Count the flashes and refer to Diagnostics using warning light flashes. |
|
The gate starts moving, but stops immediately and begins moving in the opposite direction. |
Programmed motor force is probably too low for your gate. Check that there are no obstructions preventing the gate from moving and, if necessary, increase the drive force or enable the Boost. |
|
The gate starts moving, but the warning light does not work. |
Check whether there is voltage at the FLASH output during gate operation (the voltage level does not matter, approx. 10-30Vdc). If there is voltage at the output, the problem is likely with the warning light, try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded. Check whether the wiring has short-circuited. |
|
The gate starts moving, but the S.C.A. output does not work. |
Find out which type of function is programmed for the S.C.A. output and, if the output is supposed to flash, check whether there is voltage at it (approximately 24Vdc). If there is voltage at the output, the problem is likely with the bulb. Try replacing it with a similar one to see if it works. If there is no voltage at the output, the S.C.A. output may be overloaded. Check whether the wiring has short-circuited. |
Diagnostics using warning-light flashes
During gate operation warning light flashes regularly once per second. If a problem occurs, the warning light indicates the error with two rapid consecutive sequences of flashes.
|
Flash sequence |
Error |
Solution |
|---|---|---|
|
1 flash 1-second pause 1 flash |
BlueBUS error
|
The devices connected to the BlueBUS input do not match those detected during the device detection phase. Run the detection phase again. If that does not help, try once more. Otherwise, you will need to identify the faulty device by elimination and replace it (purchase a replacement, make a warranty claim, or have it repaired). |
|
2 flashes 1-second pause 2 flashes |
Photocell triggered |
The photocellshave been triggered, which is normal if their beam is interrupted while the gate is closing. If the beam was not interrupted, the photocells may be dirty, affected by glare, or faulty. |
|
3 flashes 1-second pause 3 flashes |
Motor force limiter activated
|
During movement, increased friction is detected at the gate – it may be poorly adjusted. Try moving it by hand and readjusting it. Otherwise, it usually helps to increase the motor forceor enable the Boost function. Another possible problem is that your bottom stop is set too high. |
|
4 flashes 1-second pause 4 flashes |
STOP input activated
|
A command was sent to the STOP input, so if this was unexpected, check the devices connected to it. |
|
5 flashes 1-second pause 5 flashes |
Internal control unit error |
Wait 30 seconds and try again. If the problem persists, try to reset it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
6 flashes 1-second pause 6 flashes |
Hourly operation limit reached. |
Wait a few minutes for the cycle limiter to drop below the limit. |
|
7 flashes 1-second pause 7 flashes |
Internal electronic circuit error. |
Disconnect the entire drive for a few seconds, then try again. If the problem persists, try to reset it. Otherwise, the control unit will probably need to be repaired or replaced. |
|
8 flashes 1-second pause 8 flashes |
Continuous command active.
|
A command is being sent continuously to the drive. Check the devices connected to the OPEN input. If a timer is connected, it is probably the source of the command.
|
Diagnostics using LED flashes
On the RBA3R10 control unit of the NICE Robus RB1000 drive, there are two sets of LEDs. Their flashing or steady illumination indicates normal operation of the control unit or provides error diagnostics, as shown in the following tables.
Horizontal BLUEBUS, STOP, PP, OPEN and CLOSE LEDs
|
Indication |
Status |
Solution |
|---|---|---|
|
BlueBUS LED |
||
|
Off |
Error
|
Check the mains power connection. If it is OK, check fuses F1 and F2 and, if necessary, replace them with new ones of the same rating. |
|
On |
Serious error
|
Try disconnecting the control unitor all inputs. If that does not help, reset the unit. If the problem still persists, the control unit will probably need to be replaced. |
|
Flashing at one-second intervals |
Everything is OK |
Normal operation of the control unit. |
|
2 quick flashes |
The status of the inputs has changed |
Normal operation – the status of an input has changed STEP-BY-STEP, STOP, OPEN, CLOSE, have been activated photocells, or the drive received a command from the remote control. |
|
Series of flashes separated by a one-second pause |
More options |
The number of flashes in the series corresponds to fault diagnostics indicated by the beacon. |
|
STOP LED (Stop) |
||
|
Off |
The STOP input has been activated |
Check the devices connected to the STOP input. |
|
On |
Everything is OK |
The STOP input is not active. |
|
STEP-BY-STEP LED (also labelled P.P., Step-by-step) |
||
|
Off |
Everything is OK |
STEP-BY-STEP input is not active. |
|
On |
The STEP-BY-STEP input has been activated |
Normal operation of the control unit if an active device was connected to the STEP-BY-STEP input. |
|
OPEN LED (Open) |
||
|
Off |
Everything is OK |
The OPEN input is not active.
|
|
On |
The OPEN input has been activated |
Normal operation of the control unit if an active device was connected to the OPEN input. |
|
CLOSE LED (Close) |
||
|
Off |
Everything is OK |
The CLOSE input is not active.
|
|
On |
The CLOSE input has been activated |
Normal operation of the control unit if an active device was connected to the CLOSE input. |
Vertical LEDs L1–L8
|
Indicator |
Solution |
|---|---|
|
LED 1 |
|
|
Off |
During normal operation, indicates that the Automatic closing function is disabled. |
|
On |
During normal operation, indicates that the Automatic closing function is enabled. |
|
Flashing |
|
|
LED 2 |
|
|
Off |
During normal operation, indicates that the Close after photocell interruption function is disabled. |
|
On |
During normal operation, indicates that the Close after photocell interruption function is enabled. |
|
Flashing |
|
|
LED 3 |
|
|
Off |
During normal operation, indicates that the Always close function is disabled. |
|
On |
During normal operation, indicates that the Always close function is enabled. |
|
Flashing |
|
|
LED 4 |
|
|
Off |
During normal operation, indicates that the Standby function is disabled. |
|
On |
During normal operation, indicates that the Standby function is enabled. |
|
Flashing |
|
|
LED 5 |
|
|
Off |
During normal operation, indicates that the Peak function is disabled. |
|
On |
During normal operation, indicates that the Peak function is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 6 |
|
|
Off |
During normal operation, indicates that the Pre-flashing function is disabled. |
|
On |
During normal operation, indicates that the Pre-flashing is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 7 |
|
|
Off |
During normal operation, indicates that the function Close means Partial Opening is not enabled. |
|
On |
During normal operation, indicates that the function Close means Partial Opening is enabled. |
|
Flashing |
The function is being programmed. |
|
LED 8 |
|
|
Off |
During normal operation, indicates that the function Slave unit is not enabled. |
|
On |
During normal operation, indicates that the function Slave unit is enabled. |
|
Flashing |
The function is being programmed. |
Installing the backup battery for the NICE Robus 1000 operator
NICE PS124 backup battery is not included as standard with the operator, but it can be ordered separately. It is used in the event of a power outage, when the gate operator will be powered by it. The battery is continuously charged from the mains.
| 1. Pry off the plastic cover from the battery connector | 2. Connect the battery to the connector and position it next to the control unit |
|---|---|
![]() |
![]() |
Manual release of the NICE Robus RB1000 operator
![]() |
In the event of a power outage, you will not be able to operate the gate using a remote control. Therefore, the operator can be released using the release key and the gate can be moved manually: |
| 1. Slide the release lock cover aside | 2. Insert the release key and turn it clockwise |
|---|---|
![]() |
![]() |
| 3. Pull out the release lever | 4. You can move the gate manually |
![]() |
![]() |
Technical specifications of the NICE Robus RB1000 operator
| Model | NICE Robus RB1000 |
|---|---|
| Description | Electromechanical gearmotor for automatic operation of sliding gates in residential settings. Supplied with NICE RBA3R10 control unit, but without radio receiver. |
| Pinion | Number of teeth: 15 Tooth module: 4 Pitch: 12,6mm Pitch diameter: 60mm |
| Torque [Force] |
27Nm [1000N] - required to start the gate leaf moving |
| Rated torque [Rated force] |
15Nm [500N] - required to keep the gate leaf moving |
| Speed | 0,28 m/s |
| Rated speed | 0,14 m/s |
| Limit on consecutive cycles | 150 cycles/day (the control unit limits the number based on the restrictions; see Choosing an operator) |
| Operating time limit | 5 minutes (the control unit limits the time based on the restrictions; see Choosing an operator) |
| Service life | from 250,000 to 20,000 cycles, depending on the weight and length of the gate leaf, as well as the operator settings |
| Power supply | 230V (+10% -15%) 50/60Hz |
|
Power consumption |
450W [2,3A] |
| Insulation class | 1 - must be earthed |
| Backup power supply | available as an optional extra and can be installed NICE PS124 backup battery |
| Flashing light output | for two flashing lights 12V with a 21W bulb (e.g. NICE Lucy LUCYB, NICE Moonlight MLBT) |
| Indicator output (S.C.A.) | for one 21V, max. 4W bulb (output voltage +50% -30%); can control a small relay |
| BlueBUS output | one output for up to 15 BlueBUS devices |
| STOP input | for normally open, normally closed and 8.2KΩ constant-resistance devices |
| STEP-BY-STEP input (P.P., step-by-step) | normally open (closing triggers the “Step-by-step") |
| OPEN input | normally open (closing triggers the “Open") |
| CLOSE input | normally open (closing triggers the “Close") |
| Radio receiver | without a receiver; “SM” connector for receivers NICE SMXI, NICE OXI etc. |
| Antenna input | 52Ω for RG-58 coaxial cable (or similar) |
| Programming functions | 8 on/off functions (Level I programming) 8 adjustable functions (Level II programming) |
| Self-learning functions |
leaf length detection (calculation of acceleration and deceleration distances, calculation of the partial opening point) |
| Operating temperature | -20°C to +50°C |
| Use in saline, acidic and potentially explosive environments | no |
| Protection rating | IP44 |
| Dimensions | 210×330×303 (W×D×H) |
| Weight | 13kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]








































