NICE MC800 – control unit for two 230 V motors with MCA5R30 control board
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€206.02 including VAT
| Weight |
|---|
| 1,00 kg |
Description of NICE MC800 – control unit for two 230 V motors with MCA5R30 control board
Wiring and setting up NICE MC800 with the MCA5R30 board
NICE MC800 controls one or two 230 V AC swing gate operators and is based on the older NICE Mindy A60 control unit. This version has the MCA5R30. It features the OutSTB and the Aux PRGbutton; the older manual for the MCA5 board with OGI and Photo PRG does not apply to these.
For a single gate leaf, use M2. For two leaves, M2 opens first and M1 closes first. The control unit's 230 V AC supply, the 230 V AC motor voltage, and the low-voltage accessory outputs are separate circuits.
Before wiring: check that the board is marked MCA5R30, disconnect the mains supply, and ensure the gate cannot move on its own while you work. After installation, test the photocells, STOP, and all commands.
| Quick navigation | Procedures | Service |
|---|---|---|
| Operators and accessories | Installation and wiring | Technical data |
| Terminals | Photocells and STOP | Diagnostics |
| Initial start-up | Manual positioning | Reset |
| Standby | Programming | Receiver and remote controls |
Operators and accessories
| What | Why | Type |
|---|---|---|
| Flashing light | Flashes to warn that the gate is moving, especially at an exit with poor visibility. |
|
| Photocells | Detect an obstruction in the gate opening and trigger the appropriate safety response. |
|
| Remote control | Open and close the gate remotely. |
|
| Receiver | Receives commands from remote controls; one module is fitted in the SM connector. |
|
| Service programming | Advanced control unit settings and diagnostics. |
|
| programmer | Helps increase the range of the radio control. |
|
| Keypad | Allows you to enter a command using a code, without a remote control. |
|
| Key switch | Operate the gate with a key from a fixed location. |
|
An example of a compatible 230 V operator is the NICE HY7005. Choose the specific motor based on the dimensions, weight, and mechanics of the gate leaf.
Control box installation and wiring
NICE's original illustrations show how to install the control box and route cables through suitable glands. Click the image to enlarge it.
Mount the control box on a solid vertical surface. The mounting-hole spacing is 205 × 245 mm. After connecting the power cables, secure them with a clamp so that no strain is transferred to the terminals. Protect cable entries from water.
| Circuit | Cable and length |
|---|---|
| Control unit supply | 3 × 1.5 mm² up to 30 m; for longer runs, the manufacturer specifies 3 × 2.5 mm² and grounding at the automation system. |
| Each motor | 4 × 1.5 mm² including PE, up to 10 m; capacitor as specified for the motor. |
| Flashing light | 2 × 1.5 mm² up to 20 m, with insulation rated for mains voltage. |
| BlueBUS | 2 × 0.5 mm² up to 20 m; 2 × 1 mm² for 20–40 m. |
| Antenna | RG58 coaxial cable up to 20 m; recommended length under 5 m. |
| Key switch | Two 2 × 0.5 mm² cables up to 50 m. |
| Electric lock | 2 × 1 mm² up to 10 m. |
Board, terminals, and wiring
The illustration shows the MCA5R30 board: fuse A, power supply B, FLASH C, motors D/E, low-voltage terminals F/H, Aux PRG J, buttons K–M, SM connector P, and IBT4N connector S. Click the image to enlarge it.
| Terminal | Purpose | Connection |
|---|---|---|
| L / N / PE | 230 V AC supply | Also connect the PE protective conductor to the motors as instructed in their manuals. |
| M1 / M2 | Two 230 V AC motors | OPEN – COMMON – CLOSE, as marked. For a single motor, use M2 only. |
| FLASH | Warning light | Switched mains voltage, max. 21 W; for example NICE ELAC. |
| 1–2 / EL | Electric lock | 12 V AC, max. 15 VA. |
| 3 / 4 | Accessories | Terminal 3 = 0 V (−), terminal 4 = common +24 V DC (+); total current draw max. 200 mA. |
| 5 / OutSTB | Power supply for relay photocells | 24 V, max. 4 W; switched off in Standby. This is not OGI on the old board. |
| 6–7 | BlueBUS | Two wires, connected in parallel, with no polarity. |
| 8–10 / AUX1–3 | PHOTO / PHOTO1 / PHOTO2 | In relay photocell mode; in limit-switch mode: FCA1/FCA2/FCC1. |
| 11 / AUX4 | FCC2 or STOP | In limit-switch mode: FCC2; in photocell mode: an additional STOP input. |
| 12 / STOP | Safety input | NO, NC or 8.2 kΩ, depending on the combination. |
| 13 / SbS | Step-by-step | Volt-free NO contact relative to terminal 4. |
| 14 / OPEN | Open | Volt-free NO contact relative to terminal 4. |
| 15 / CLOSE | Close | Volt-free NO contact relative to terminal 4; the function can be changed to partial opening. |
For NICE EKS use the C–NO contact. Do not apply an external voltage to the command inputs. Connect the OXIBD antenna directly to the receiver; the antenna is not part of the FLASH warning light circuit.
Photocells, photocell test and STOP
Choose the wiring according to the actual photocell type and Standby status. TX is the transmitter; RX is the receiver. EPM has a relay C–NC contact; EPMB uses two-wire BlueBUS. Terminal numbers on other photocell types may differ.
EPM relay photocells
Figure 7 NICE: combined wiring with Standby enabled; relay photocells are powered via OutSTB. Click to enlarge the image.
One pair of EPM photocells without photocell testing, Standby off: Power TX and RX from terminals 3/4; connect the RX C–NC contact between 4/COMMON and 8/PHOTO. For NICE EPM, make the following connections:
| MC800 MCA5R30 | NICE EPM TX | NICE EPM RX |
|---|---|---|
| 3 / 0 V | 2 | 2 |
| 4 / +24 V | 1 | 1; connect to RX 4 / C |
| 8 / PHOTO | — | 5 / NC |
Terminal numbers may differ for other relay photocell types. On the MCA5R30, output 5 functions as OutSTB, not OGI.
Figure 10 NICE: photocell test wiring; output 5 functions as OutSTB, not OGI. Click to enlarge the image.
For the photocell test shown in Figure 10, connect TX 1 to MC800 terminal 4 and TX 2 to terminal 5. RX remains powered from terminals 3/4, and its C–NC contact connects to the selected PHOTO input. Do not use output 5 for another load at the same time. After changing the wiring, repeat device learning and test the photocell while the gate is moving.
Aux PRG and LP: For relay photocells, LP must be lit; when AUX inputs are used as limit switches, it must be off. Leave unused AUX inputs unconnected. After switching, check the resulting LP status and repeat device learning.
BlueBUS and addressing
Connect BlueBUS photocells to terminals 6–7 using two wires, with no polarity. If AUX1–4 are used as drive limit switches, configure Aux PRG so that LP is off: AUX1/8 = FCA1, AUX2/9 = FCA2, AUX3/10 = FCC1, and AUX4/11 = FCC2. Connect limit-switch contacts relative to common terminal 4; leave unused inputs unconnected.
Original Table 3, including jumper positions: use the same address on the TX and RX of each pair, and a different address for each additional pair. Click to enlarge the image.
| Address | Response |
|---|---|
| PHOTO / PHOTO II | During closing, stops and reverses direction. |
| PHOTO 1 / PHOTO 1 II | During closing, stops and reverses; during opening, stops and resumes after the beam is cleared. |
| PHOTO 2 / PHOTO 2 II | During opening, stops and reverses direction. |
| PHOTO 3 | Configuration not permitted for MC800. |
BlueBUS has a capacity of up to 15 load units, not necessarily 15 pairs of photocells. Run a new device-learning procedure after adding or replacing a device.
STOP input wiring
| Devices | Wiring |
|---|---|
| Multiple NO contacts | In parallel. |
| Multiple NC contacts | In series. |
| Two 8.2 kΩ safety edges | In parallel; for more than two devices, connect in cascade with a single 8.2 kΩ end-of-line resistor. |
| NO + NC | According to NICE Table 2, connect in parallel, with an 8.2 kΩ resistor in series with NC; this also allows a combination of NO, NC and 8.2 kΩ safety edges. |
During learning, STOP memorises the connected state. A subsequent change triggers a stop with a short reverse movement. Do not short-circuit the input as a workaround for a fault.
Simplified MC800/MCA5R30 wiring and setup procedure
This procedure describes an MCA5R30 board with one pair of EPM relay photocells connected to PHOTO to protect the closing movement. For BlueBUS or multiple pairs, use the relevant diagram above.
Step 0. Wiring
Connect the L/N/PE supply, 230 V AC M1/M2 motors, capacitors and warning light according to the terminals on the board. For a single leaf, leave M1 unused. Wire the photocells according to the selected mode above; for EPM without a photo test and with Standby off, connect 3/4 to TX/RX and RX contact 4–5 between 4/COMMON and 8/PHOTO.
Step 1. Reset only when deliberately restoring factory settings
There is no need to reset the control unit “just in case” when wiring a new system. If you need to erase your own settings, follow the reset procedure and then teach the devices and travel again.
Step 2. Select AUX and Standby modes
The MCA5R30 board has an Aux PRG. For relay photocells, check that LP is lit; for AUX configured as limit switches, check that LP is off. For relay wiring, choose the diagram according to whether Standby. Selecting AUX alone does not replace correct TX/RX power supply.
After power is connected, the green BlueBUS LED should flash regularly about once per second, the photocell indicators should show activity, and the FLASH warning light should be off. If any check fails, inspect the wiring before teaching.
Step 3. Detection of connected devices
Hold Open + Stop/Set and release the buttons when L1/L2 flash rapidly, after about 3 seconds. When complete, L1/L2 should go out and STOP should be lit. Run the learning procedure even with no devices connected to BlueBUS/STOP, and repeat it after changing accessories.
Step 4. Detection of gate-leaf movement
Buttons and LEDs L3/L4 used for travel learning. Click the image to enlarge it.
Move the unlocked leaves to approximately halfway along their travel, lock the drives again, and check the motor force (level II/L6) before learning. Hold Stop/Set + Close and release when L3/L4 flash rapidly, after about 3 seconds. The control unit will close M1 and M2 in sequence, open M2 and M1, and finally close M1 and M2. After successful completion, L3/L4 go out.
If a leaf opens instead of closing, interrupt learning by pressing Open or Close. With the power disconnected, swap the two direction wires for the motor concerned; COMMON and PE remain unchanged. With 230 V AC, this is not a “polarity reversal.” Then repeat the learning procedure. A photocell or STOP can interrupt learning.
Step 5. Remote control and functional test
Pair the remote according to the receiver actually installed: SMXI, OXI or another compatible module. The existing SMXI procedure is described in the radio section; there is no need to reset the control unit for this. Test OPEN, CLOSE, STOP, both directions and the photocell response.
Manual setting of limit positions and slowdown
The R30 uses positions 0, A and 1. Full manual learning starts with a short press of Stop/Set while L3/L4 are flashing rapidly; mixed learning of selected positions requires automatic learning to have been completed first. Point A can be configured only after the open position of the relevant leaf has been recorded.
Original image 16 NICE. Click the image to enlarge it.
Full manual learning
The gate must be stationary, the motors must be engaged for operation, and the connected devices must already have been learned. Press and hold Stop/Set + Close; after about 3 seconds, release them when L3/L4 flash rapidly, then briefly press Stop/Set. The position L1 will start flashing. Briefly press Open or Close to move the selection between flashing LEDs; hold Open or Close to move the corresponding leaf. At each desired position, hold Stop/Set for at least 3 seconds. After 2 seconds, the corresponding LED lights steadily; when you release the button, the next one starts flashing. Do not leave more than 10 seconds between successive button presses; otherwise the procedure ends and saves the changes made so far.
| Sequence / LED | What to set | How to confirm |
|---|---|---|
| 1 / L1 | Move M1 to the fully closed position 0 | Hold Stop/Set for at least 3 seconds; L2 will then flash. |
| 2 / L2 | Move M2 to the fully closed position 0 | Hold Stop/Set for at least 3 seconds; L5 will then flash. |
| 3 / L5 | Move M2 to point A, where it starts slowing down during closing | Hold Stop/Set for at least 3 seconds; L6 will then flash. |
| 4 / L6 | Move M1 to point A, where it starts slowing down during closing | Hold Stop/Set for at least 3 seconds; L7 will then flash. |
| 5 / L7 | Move M2 to the fully open position 1 | Hold Stop/Set for at least 3 seconds; L8 will then flash. |
| 6 / L8 | Move M1 to the fully open position 1 | Hold Stop/Set for at least 3 seconds, then release the button. |
The manufacturer states that points A can be set only after the open positions have been recorded. If the board has not yet recorded them during the first manual learning procedure, save L7/L8 first, then repeat the procedure for L5/L6. For a single leaf, only L2, L5 and L7 are used. After learning, run a complete opening and closing cycle; when opening, the leaves should stop a few centimetres before the mechanical stop, and when closing, they should reach the closing stop.
Fine-tuning recorded positions
Automatic learning must first complete successfully. Then hold Stop/Set + Close and release the buttons when L1 starts flashing. Briefly press Open/Close to select a position LED, hold to move the leaf, and save the position by holding Stop/Set for at least 3 seconds. Adjust the other positions in the same way. After making a change, test a complete gate cycle.
Standby mode
The MC800 with MCA5R30 board has a low-power Standby mode. When enabled, the control unit enters this mode about 5 minutes after a movement is completed correctly, or after about 10 minutes if it has not yet been configured. In this mode, the OutSTB output is switched off and, when wired correctly, the control unit itself consumes less than 0.5 W, excluding accessories. Wire relay photocells according to whether Standby is enabled or disabled.
When the power is switched on, three flashes of LEDs L1–L8 confirm that Standby is active. To change the mode, hold Open + Stop/Set + Close simultaneously and release at the third flash; when enabling Standby, L1–L8 flash three times again, but they do not when disabling it. After changing the setting, check the wiring and test the photocells.
Programming functions and parameters
With the gate stationary, hold Stop/Set until L1 starts flashing. Open/Close selects an item. In level I, a brief press of Stop/Set changes the state: a short flash = OFF, a long flash = ON. Level I functions are disabled by default. Do not wait more than 20 seconds between successive button presses; when finished, wait about 10 seconds for the mode to exit.
Level I – ON/OFF functions
| LED – function | ON and OFF states |
|---|---|
| L1 – Automatic closing | ON: After opening, the control unit counts down the pause time and closes the gate. OFF (default): Semiautomatic mode. |
| L2 – Closing after photocell activation | ON: If L1 is active, a photocell activation reduces the pause to 5 seconds; even without L1, activation can trigger closing after the set pause. OFF (default): No such link. |
| L3 – Always close | ON: When power is restored, the control unit checks for 10 seconds whether the gate is open and closes it after a 5-second warning-light pre-flash. OFF (default): The gate remains in position. |
| L4 – Lock engagement push | ON: Before opening, briefly pushes the gate towards the closed position. OFF (default): No push. |
| L5 – FLASH as lighting | ON: Changes the FLASH output to auxiliary lighting. OFF (default): FLASH controls the warning light. |
| L6 – Pre-flashing | ON: The warning light flashes for 3 seconds before movement. OFF (default): Starts flashing when movement begins. |
| L7 – CLOSE as Partial Open 1 | ON: The CLOSE input triggers partial opening. OFF (factory default): The input closes the gate. |
| L8 – Pressure maintenance | ON: For compatible hydraulic drives, pressure is restored with a brief closing movement after 4 hours in the closed position. OFF (factory default): No pressure restoration. |
Level II – parameter values
Select the parameter's input LED, then hold Stop/Set for about 3 seconds until the LED for the current value lights up. Continue holding Stop/Set and use Open/Close to select the LED for the new value. After releasing the button, wait for the controller to return to normal mode. The input LED and the value LED have different meanings. The highlighted value is the factory default.
| Input LED – parameter | Setting LED – value |
|---|---|
| L1 – Pause time Time before automatic closing. |
L1 – 5 s L2 – 15 s L3 – 30 s L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – Step-by-step operation Sequence of commands for SbS, OPEN, CLOSE and radio control; with L4, L5, L7 and L8, the behavior of OPEN and CLOSE also changes. |
L1 – open–stop–close–stop L2 – open–stop–close–open L3 – open–close–open–close L4 – condominium mode L5 – condominium mode 2 L6 – step-by-step 2; a brief command triggers partial opening L7 – hold-to-run control L8 – semi-automatic opening, hold-to-run closing |
| L3 – Opening delay Delay between the opening of the leaves, as a proportion of the operating time. |
L1 – 0% L2 – 10% L3 – 15% L4 – 20% L5 – 25% L6 – 30% L7 – 40% L8 – 50% |
| L4 – Closing delay Delay between the closing of the leaves, as a proportion of the operating time. |
L1 – 0% L2 – 10% L3 – 15% L4 – 20% L5 – 25% L6 – 30% L7 – 40% L8 – 50% |
| L5 – Time adjustment Adjusts the closing time relative to the opening time. Read the initial value from the LED on the specific control board. |
L1 – 0% L2 – 20% L3 – 30% L4 – 40% L5 – 60% L6 – 70% L7 – 80% L8 – 100% |
| L6 – Motor force Force of both motors; check the mechanics before increasing it. |
L1 – 25% L2 – 35% L3 – 45% L4 – 55% L5 – 65% L6 – 75% L7 – 85% L8 – 100% |
| L7 – Soft-start time Duration of the soft start at the beginning of movement. |
L1 – 0 s L2 – 0.5 s L3 – 1 s L4 – 1.5 s L5 – 1.8 s L6 – 2 s L7 – 2.5 s L8 – 3 s |
| L8 – Partial opening Range of the Partial Open 1 command. For both leaves, the percentage is calculated from the smaller of the configured opening distances. |
L1 – M2 to ¼ L2 – M2 to ½ L3 – M2 to ¾ L4 – M2 fully open L5 – both leaves to ¼ L6 – both leaves to ½ L7 – both leaves to ¾ L8 – both leaves to the smaller full opening distance |
With L2/L4 (condominium mode), the SbS or OPEN command has no effect while opening, and CLOSE reverses the direction; while closing, SbS or OPEN reverses the direction, and CLOSE has no effect. L2/L5 works the same way, but a command held for more than 2 seconds triggers STOP. With L2/L6, a brief command of up to 2 seconds triggers partial opening; L2/L7 requires the command to be held continuously, while L2/L8 requires it to be held during closing.
For parameter II/L5, two values are marked as defaults: L4 = 40% and L5 = 60%. Before changing it, check which value LED is actually lit on the specific control board.
Example: 60 s: enable Level I/L1 and at Level II/L1 select value L5. If L2 after the photocell is active, the pause may be shortened.
Remote controls and service programmers
An SMXI or OXI receiver from an existing system can be retained if it is compatible with the remote controls in use. Install the plug-in receiver with the power disconnected. For a new receiver, follow its own instructions; matching remote-control frequencies alone are not sufficient.
Figure 24 NICE. Click the image to enlarge it.
| Output of the SMXI/SMXIS or OXI receiver in Mode 1/2 | Control unit command |
|---|---|
| 1 | SbS – step-by-step |
| 2 | Partial Open 1 |
| 3 | OPEN |
| 4 | CLOSE |
For an existing SMXI: in Mode I, hold the receiver button for at least 3 seconds until the LED lights up, then hold the remote-control button for at least 2 seconds within 10 seconds. Three flashes confirm that the code has been stored. For a specific command, use the receiver’s corresponding Mode II; do not automatically apply this procedure to OXI or OXIBD.
NICE OXIBD is installed in the SM connector; the antenna connects directly to the receiver. Remote control NICE ON3EBD Pair it according to the instructions for the receiver in use. The extended commands in the following table apply to OXI/OXIFM/OXIT/OXITFM receivers. For OXIBD, follow its own instructions.
Extended Mode II for OXI/OXIFM/OXIT/OXITFM receivers: Assign the command number to a button according to the instructions for that receiver. The following table does not describe OXIBD mode.
| No. | Command | Function |
|---|---|---|
| 1 | SbS | Step-by-step. |
| 2 | Partial 1 | Partial opening according to Level II parameter L8. |
| 3 | OPEN | Open. |
| 4 | CLOSE | Close. |
| 5 | STOP | Stop movement. |
| 6 | SbS condominium | Command in condominium mode. |
| 7 | High-priority SbS | The command is accepted even when the automation is locked. |
| 8 | Partial 2 | Leaf M2 opens halfway. |
| 9 | Partial 3 | Both leaves open halfway. |
| 10 | Open and lock | Locks further standard commands after opening. |
| 11 | Close and lock | Locks further standard commands after closing. |
| 12 | Lock automation | Stops movement and locks further standard commands. |
| 13 | Unlock automation | Restores standard operation. |
| 14 | Timed lighting | Turns on the auxiliary light, which switches off after a set time. |
| 15 | Lighting ON/OFF | Toggles the auxiliary light on and off. |
BusT4 and programming
NICE IBT4N is installed in the board connector with the power off. Allows you to connect NICE OVIEW according to its instructions. For the NICE BIDIWIFI module, check compatibility and available functions for MCA5R30 in the module’s latest instructions.
Figure 25 NICE. Click to enlarge the image.
Troubleshooting
If an error occurs, note the number of red BlueBUS flashes and the status of the other LEDs. Two quick green flashes indicate an input change or a received command. When Standby is active, some indicators may switch off after a period of inactivity.
Figure 23 NICE identifies BlueBUS, STOP and the status LEDs. Click to enlarge the image.
| Symptom / code | Check and remedy |
|---|---|
| 1 red flash | BlueBUS configuration changed – check the addresses and repeat the learning procedure. |
| 2 red flashes | Photocell obstructing movement – check for an obstruction, alignment, power supply and wiring. |
| 4 red flashes | STOP – check the safety device and wiring. |
| 5 red flashes | Internal parameter error; try a command after 30 seconds. If the error returns, contact service. |
| 7 red flashes | Electrical fault; L1 = protection activated/motor disconnected, L2 = faulty learned limit switch, L3 = limit switch present but not learned, L4 = general anomaly. |
| 8 red flashes | Continuous command – check the button or relay. |
| 9 red flashes | Automation locked by a command; unlock it with the corresponding command. |
| Board LED | Meaning / first check |
|---|---|
| BlueBUS green, 1×/s | Normal operation. |
| BlueBUS permanently off / on | Power supply, fuse or board fault. |
| STOP off | Active or faulty STOP. |
| SbS / OPEN / CLOSE on | The corresponding input is active; a continuous state with no command explains the lockout. |
| LS1/LS2 OPEN/CLOSE | If limit switches are connected, interpret their status according to their wiring and AUX mode; the state change should correspond to movement. |
| L1 + L2 flashing slowly | Run device learning. |
| L3 + L4 flashing slowly | Run travel learning or check whether the board settings have changed. |
5 A F fuse
The MCA5R30 board has a 5 A F fast-acting fuse. Disconnect the power before checking and replace it only with an identical type.
The cover is marked 5 A F. Click to enlarge the image.
Clearing the control unit memory
Resetting erases custom settings; it is not a required first step when wiring a new system. Hold Open + Close until L1/L2 start flashing, then release. Set the AUX mode again, program the devices and travel limits, review the custom parameters, and run tests. The plug-in receiver memory has a separate procedure.
Temporary movement when a safety device is faulty
If the device rejects a normal command when a safety input is faulty, the manufacturer allows temporary movement by holding the command continuously: send the command, repeat it within 3 s, and hold it. After about 2 s, the gate moves only while the command is held. Then fix the cause of the fault and test the safety devices again.
Technical specifications and inspection
| Parameter | MCA5R30 / MC800R30 |
|---|---|
| Control unit power supply | 120–250 V AC, 50/60 Hz; 230 V AC on our mains supply. |
| Rated power consumption | 900 W. |
| Standby power consumption | Less than 0.5 W without accessories, when wired according to the original diagram. |
| Motors | One or two compatible 230 V AC operators. |
| FLASH | Mains-voltage flashing light, max. 21 W. |
| EL | 12 V AC electric lock, max. 15 VA. |
| OutSTB | 24 V, max. 4 W; switches off in Standby mode. |
| BlueBUS | Up to 15 load units. |
| Operating temperature / protection rating | −20 to +55 °C / IP54 with the enclosure intact. |
| Enclosure dimensions and weight | 310 × 232 × 122 mm; 4.1 kg. |
After setup, test opening, closing, and stopping with every command in use. Test each pair of photocells and each STOP device separately and while the gate is moving; check the leaf sequence and stops. In the event of a power failure, release the operators themselves according to their instructions.
Inspect the automation system at least every 6 months. For a service request, provide the MCA5R30 and motor model labels, a photo of the terminals, the LED status, and the number of red BlueBUS flashes.
The PDF below is for the older MCA5 board with OGI and Photo PRG. The supplied MCA5R30 has OutSTB and Aux PRG; when wiring and setting it up, use the procedures above on this page.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]










