NICE Hyppo HY7005 – swing gate operator for a gate leaf up to 3 m/800 kg
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€502.00 including VAT
| Weight |
|---|
| 13 kg |
Description of NICE Hyppo HY7005 – swing gate operator for a gate leaf up to 3 m/800 kg
NICE HYPPO HY7005 – articulated-arm swing gate operator
NICE HYPPO HY7005 is a standalone electromechanical motor for one gate leaf. It has a 230 V AC, articulated arm, and is non-reversible. It monitors the gate leaf position using opening and closing limit switches. It requires a separate control unit and safety accessories; in the event of a power failure, it can be released with a key.
Disconnect the power supply and any backup power before opening the motor or control unit. When operating manually, secure the gate leaf to prevent unintended movement.
When to choose this operator
HYPPO is suitable for swing gates with the articulated arm mounted on the inside. The choice depends on the gate leaf’s length and weight, its resistance to movement, hinge position, and the clearance needed for the arm’s full range of motion.
| Maximum gate leaf length | 3 m; the permitted weight decreases as the length increases. |
|---|---|
| Weight according to the graph | For a gate leaf of around 2 m the upper curve reaches approximately 800 kg. At 3 m the graph shows below 400 kg. Assess the specific weight against the relevant curve and gate conditions. |
| Duty cycle | 30% |
The 3 m and 800 kg limits do not apply simultaneously. The limits apply to one motor and one gate leaf. The gate’s height and shape, solid infill, and strong winds can significantly reduce these values. Duty cycle as a percentage is not the number of cycles per hour or continuous operation.
The horizontal axis shows length in metres; the vertical axis shows weight in kilograms. For HY7005, use the operating range marked for this model.
Compatible accessories
Choose accessories according to the installed control unit, connectors, and voltage. The following wiring and procedures apply to MC800 / MCA5R30.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors and safety devices. |
|
| Warning light | Indicates gate movement and can accommodate an antenna. |
|
| Photocells | They monitor the gate area; the response depends on their positioning. | |
| Safety edge | Provides protection on contact with the gate leaf; mandatory in an MC800 setup. |
|
| Wireless photocells | A solution that avoids running cables to the photocells. |
|
| Receiver | Receives commands from remote controls; one receiver is included with the SM. |
|
| Transmitter | Remote control, depending on the installed receiver. | |
| Antenna | Helps improve the remote's range. |
|
| Keypad | Send a code-based command without a remote control. |
|
| Key switch | Operate with a key from a fixed location. |
|
| Card reader | Operate using an assigned card or key fob. |
|
| Electric lock | Additional leaf locking, synchronised with the control system. |
|
| Extended arm | Greater reach for different mounting geometries. | |
| External release | Manual access during a power outage when there is no other entrance. |
|
| Wi-Fi / GSM control | Remote command via a volt-free contact. |
|
| Programming and integration | Advanced configuration and diagnostics. |
|
FT210B are not suitable for MC800 or MC824H: they require different FT A / FT B / FT C addresses. Select the compatible photocells listed above.
Standalone motor and control unit
The offer is for one HYPPO HY7005 motor with articulated arm. The standalone motor does not include a control unit. A double-leaf gate requires two matching motors; this does not increase the limit for a single leaf. Choose the control unit, photocells, warning light, receiver and remotes to suit your setup.
| Setup | Control unit | Key difference |
|---|---|---|
| HY7005 | MC800 | 230 V AC, built-in limit switches. MC200 is an option for a single motor. |
For an existing gate, follow the instructions for the control board installed. The manual for the current MC800 does not apply to the old A60, and MC824HR30 procedures do not automatically apply to a different MC824H generation.
Installing an articulated-arm operator
Before installation
- The leaf must move smoothly by hand along its entire travel. Check the hinges, leaf strength and load capacity of the mounting points.
- Fit solid mechanical opening and closing stops to limit travel and allow the control unit to learn the travel limits.
- Leave enough clearance for the motor body, the full arm movement and the release handle. Assess potential pinch and entrapment points, and plan suitable safeguards.
- Fit the mounting plate to the post and the front bracket to the gate leaf. The mounting dimensions and substrate strength are critical.
Mounting dimensions A and B
Measure dimensions A and B as shown in the illustration. The table applies to the standard HY7005 articulated arm and shows the opening angle for each pair of dimensions, in millimetres.
| B | A = 110 mm | A = 130 mm | A = 150 mm |
|---|---|---|---|
| 90 mm | 85° | 98° | 104° |
| 110 mm | 91° | 97° | 103° |
| 150 mm | 110° | 120° | 115° |
| 200 mm | 105° | 110° | 115° |
| 250 mm | 105° | 110° | 110° |
| 300 mm | 100° | 105° | 105° |
| 350 mm | 95° | 100° | 96° |
The angle is determined by the geometry, not freely adjustable via the control unit. Before final fastening, release the motor and check the full travel of the leaf and arm. The stops must prevent movement beyond the safe area.
Extended arm HYA12
NICE HYA12 extended articulated arm provides greater reach. The illustration also defines dimension D. The maximum A/B/D values are installation limits, not recommended post dimensions. Do not automatically apply the standard arm angle table to the HYA12.
| Dimension | Standard arm | HYA12 |
|---|---|---|
| A max. | 150 mm | 400 mm |
| B max. | 350 mm | 450 mm |
| D max. | 450 mm | 800 mm |
Mounting the plate and bracket
- Determine whether the installation is left- or right-handed when viewed from inside the property. The same model can be adapted for either side by positioning the plate and assembling the arm accordingly.
- Secure the mounting plate A to the solid post substrate, and the bracket B to a solid part of the gate leaf. Here, A/B indicate components, not the mounting dimensions in the previous table.
- Bolt the motor to the plate. Use the elongated mounting holes to correct minor alignment deviations.
- Assemble the arm for the selected side. Lubricate the screws as specified in the installation manual before assembly, then fit the washers and fasteners.
- With the motor released, manually test the leaf through its full travel up to the stops; then fully tighten the fasteners.
Left-hand installation, viewed from inside:
Right-hand installation, viewed from inside:
Mechanism cover and protection
After adjustment, fit the cover and release handle, then secure them with screws. Check the cable glands and ensure the cover is closed. Water must not enter the drive or control unit; protect cables from the arm and the moving gate leaf.
Manual release
- Stop the automation, disconnect the power supply, and secure the gate leaf against unintended movement.
- Slide the lock cover upwards. Insert the key and turn it clockwise.
- Turn the release handle as shown; then move the gate leaf manually.
- Before automatic operation, return the mechanism to the locked position with the handle vertical. Check that the drive is engaged, remove the key, and close the lock cover.
If you have no other access to the property, plan for access during installation: NICE KIO with KA1 cable allows manual release from outside. Install and test the assembly before putting the gate into operation.
Wiring and electrical connections
Route and protect the mains cable, motor wires, and low-voltage signals according to their voltage and environment. The supply to the control unit includes L, N, and PE; protect it with suitable overcurrent protection and a device for complete disconnection. Secure the cables with cable glands and strain relief.
| Circuit | Cable | Application |
|---|---|---|
| Supply to control unit | 3 × 1.5 mm² | Up to 30 m; L, N, and PE. For longer supply cables, use 3 × 2.5 mm² and protective earthing at the automation unit as specified in the control unit manual. |
| Motor | 4 × 1.5 mm² | Up to 10 m; open, common, close, and protective PE. |
| BlueBUS | 2 × 0.5 mm² | Up to 20 m; for lengths over 20 m and up to 40 m, use 2 × 1 mm². Non-polarized. |
| Flashing light | 2 × 1.5 mm² | Up to 20 m, mains-powered FLASH. |
| Electric lock | 2 × 1 mm² | Up to 10 m; output 12 V AC / max. 15 VA. |
| Key switch | 4 × 0.5 mm² | Up to 50 m; alternatively, two 2 × 0.5 mm² cables. |
| Antenna | RG58 | Up to 20 m; less than 5 m is recommended. |
Check the cross-section and routing against the cable lengths and the manual for the installed control unit.
Motor and control unit wiring
The HY7005 has a 230 V AC motor and built-in limit switches. The control unit procedure below applies to the MC800 with an MCA5R30 board and OutSTB. For MC200 or the legacy A60, use the respective manual. The older MCA5 board has different labels and must not be confused with the MCA5R30.
| Left motor | Terminal block Open / Common / Close (open / common / close). PE connects to a separate protective terminal. |
|---|---|
| Right motor | Compared with the left motor, swap Open and Close. Common and PE must not be swapped. |
| Single gate leaf | For the MC800, use M2; leave M1 unused. |
| Two gate leaves | M2 opens first; M1 closes first. |
1 is the cable gland, 2 motor terminal block, 3 protective earthing. An AC motor circuit has no DC +/− polarity. Torque is adjusted at the control unit.
MC800 – accessory terminals and polarity
| 3 / 4 – power supply | 3 = 0 V (−), 4 = Common +24 V DC (+), combined max. 200 mA for auxiliary devices. |
|---|---|
| 5 / 3 – OutSTB | 5 = +24 V, 3 = −; switched power supply for relay photocells, max. 4 W. It is switched off in Standby. Do not confuse it with OGI on the older board. |
| 6 / 7 – BlueBUS | Power and data over two wires; no +/− polarity. |
| 1 / 2 – ELS | Electric lock 12 V AC, max. 15 VA; no DC polarity. |
| FLASH | Self-flashing warning light 230 V AC, max. 21 W; for example, ELAC. Do not connect the low-voltage ELDC here. |
| 4 / 13 – SbS | Volt-free NO contact between Common 4 and SbS 13 for step-by-step operation; the contact is non-polarized. |
| 4 / 14 and 4 / 15 | Voltage-free NO contact for opening (14) or closing (15). |
| 4 / 12 – STOP | Learned NO, NC, or 8.2 kΩ safety input; the contacts are non-polarized. |
| 8–11 – AUX | Limit switches: 8 FCA1, 9 FCA2, 10 FCC1, 11 FCC2; LP off. Relay photocells: 8 PHOTO, 9 PHOTO1, 10 PHOTO2; 11 changes to STOP; LP on. These AUX functions are mutually exclusive. Unused AUX inputs remain unconnected. |
The diagram shows combined relay and BlueBUS wiring with Standby enabled. Power the relay TX/RX units from OutSTB as shown; for a different mode, use the relevant control unit diagram. The HY7005 microswitches are built into the motor circuit. Do not route voltage-free contacts from the Open/Common/Close terminal block to AUX. AUX settings.
Setting the HY7005 limit switches
- Disconnect the power, release the motor, and manually move the gate leaf to the closed position against the mechanical stop.
- Turn the relevant cam until you hear the microswitch click. Set the second cam with the gate leaf open for the opposite direction.
- Return the handle to the vertical locked position.
- During a controlled test, check the direction of travel, stopping, and contact with the stops. Disconnect the power again before making any further adjustments to the cams.
- Disconnect the power again after the test. Only then tighten the cam fixing screws and fit the cover.
Mechanical stops are still required. Setting the cams in the motor is a separate procedure from learning the travel on the MC800.
Photocells and safety inputs
Position the photocells according to the gate leaves' movement and the risks posed by the gate. Align the TX/RX units correctly. Protection across the opening does not replace protection at the crushing points around the hinge and arm.
The MC800 supports both BlueBUS and relay photocells, including their combined use according to the correct diagram. The AUX mode and TX/RX power supply must match the wiring and the Standby or photocell-test settings. BlueBUS EPMB, EPLB, EPSB, EPMORB, EPMOB a F210B have two non-polarized wires. Each pair needs the correct, unique address.
Relay EPM, EPMOR or EPMA require setting AUX for photocells with LP illuminated. RX contact C–NC connects between Common 4 and 8 PHOTO / 9 PHOTO1 / 10 PHOTO2. Wire the TX/RX power supply and test connections according to the mode, including polarity 3− / 4+ and OutSTB 5+. For the EPM, both TX and RX have terminal 1 = + and 2 = − for DC power; RX has 4 = COM and 5 = NC. These numbers do not automatically apply to a different photocell model. Connecting the contact alone is not enough; power and configuration are also required. Relay photocell procedure.
Sensitive safety edges are required for an installation with the MC800. Select their type and position so the installation passes the impact test under all operating conditions. Connecting the safety edge to the STOP safety input.
Test each pair during both opening and closing, as well as STOP and all installed sensitive edges. Do not disable a safety device by bridging it just to get the gate moving.
Initial startup and learning
Carry out these steps after the mechanical and electrical checks. Engage the motor in automatic mode and check the stops, clear travel path, and M1/M2. Be ready to stop the gate during its first movement.
Set the HY7005 limit switches. Before learning, check that the force setting on the MC800 is suitable (Level II parameter L6). The HY7005 is electromechanical; the hydraulic motor pressure-hold function must not be enabled for it.
After switching on the power, the BlueBUS LED must flash about once per second, the LEDs on connected BlueBUS photocell TX/RX units must flash, and the FLASH beacon must be off. If any check fails, disconnect the power and any backup supply, then check the wiring before proceeding.
1. Device recognition
- Press and hold Open ▲ + Stop/Set.
- Release both buttons when L1/L2 start flashing rapidly, after about 3 seconds.
- Wait for the process to finish. Success: STOP is lit and L1/L2 are off. L3/L4 may flash to indicate that position learning is required.
Repeat after adding or removing a BlueBUS/STOP device. Carry out learning even when no accessories are connected.
2. Automatic position learning
- Press and hold Stop/Set + Close ▼.
- Release the buttons when L3/L4 start flashing rapidly, after about 3 seconds.
- Watch for: M1 closes, M2 closes, M2 opens, M1 opens, M1 closes, and M2 closes; each time reaching the corresponding stop. With a single motor, only M2 moves.
- Success is confirmed when L3/L4 go out.
If a motor opens instead of closing during the first closing movements, stop the learning procedure using the Open ▲ or Close ▼. Disconnect the power supply and any backup power, then correct the direction of the relevant motor by swapping Open and Close; Common and protective earth (PE) remain on their respective terminals. If the sequence is incorrect, correct M1/M2. Start the learning procedure again from the beginning. Activation of a photocell or STOP interrupts the procedure and L1 flashes; remove the cause and repeat the learning procedure.
3. Testing and handover
Test full opening and closing cycles, stops, slowdowns, leaf overlap, and manual release. Check every safety device, stopping, and reversal of direction after an obstruction. Measure the forces and assess the entire assembly. Do not set a high force as a substitute for fixing a gate that is sticking. The user must receive the manual and know how to release the drive safely.
Manual and mixed learning: detailed control unit procedure. Automatic learning must be completed before mixed learning.
Settings and remote controls
Set automatic closing, pause time, step-by-step operation, slowdown, and force to suit the gate. Repeat the tests after changing the force or safety functions. The full ranges, LEDs, and factory settings are listed in the control unit programming tables.
Receiver, remote control, and antenna
A standalone motor does not have a built-in radio receiver. An SM receiver is fitted in the control unit. NICE OXIBD also supports bidirectional ON3EBD; OXILR use with ON3ELR. With the older OXI select transmitters according to the stored coding. The same frequency alone does not guarantee compatibility.
Connect the coaxial cable according to the receiver: directly to the receiver for OXIBD, and according to the control unit wiring diagram for OXI. Pairing and deleting remote controls. Deleting the radio memory is not the same as resetting the board or learning the positions.
What to check when a fault occurs
| Symptom | What to check |
|---|---|
| The gate does not move | Power supply, release mechanism engagement, and STOP. Check the power supply and fuses with the power disconnected. |
| The motor runs, but the leaf stays still | Gear engagement and arm fastening; return the release mechanism to the locked position. |
| The gate stops or reverses | First check manual movement and the arm's clearance, then the photocells, STOP, and stops. Do not increase the force without identifying the cause. |
| Learning does not complete | Motor sequence and direction, stops, and safety devices. For HY7005, also check the limit-switch cams. |
| The remote control does not work, but the button does | Battery, coding, transmitter stored in the receiver, and antenna. |
| Fault after changing photocells | Addresses and cables, then repeat device recognition. |
Beacon and LED flash codes: diagnostics and repairs. Record the settings before resetting. Resetting the board, clearing the receiver, and performing new learning are different procedures; follow the manual for the installed control unit.
Inspection and maintenance
Have the entire assembly inspected at least every six months; in cases of intensive use or harsh environments, inspect it more often according to the maintenance schedule. Check the hinges, fastenings, arm play, stops, release mechanism, cable glands, and cables. Test the photocells and STOP, and record the inspection.
Stay clear of the gate leaf and articulated arm while they are moving. Do not let children play near the gate, and keep remote controls out of their reach. Keep the area around the gate clear. Clean the photocell surfaces and lenses without using aggressive cleaning products. Do not rinse the motor with a pressure washer. After work on the mechanism, electrical circuits, or safety settings, repeat the functional and safety tests. If the arm is damaged, there is unusual noise, or the system moves on its own, take the automation out of service and arrange repairs.
NICE HYPPO HY7005 technical specifications
| Type | Electromechanical irreversible articulated-arm drive for one gate leaf. |
|---|---|
| Motor | 230 V AC / 50 Hz |
| Current | 1.2 A |
| Power consumption | 258 W |
| Torque | 400 Nm |
| Rotation speed | 1.7 rpm |
| Duty cycle | 30% |
| Position detection | Opening and closing limit switches |
| Ingress protection rating | IP43 |
| Operating temperature | −20 to +50 °C |
| Dimensions | 350 × 165 × 242 mm (width × depth × overall height) |
| Weight | 13 kg |
| Gate leaf limits | Up to 3 m; find the specific weight in the limit graph. |
The overall height of 242 mm includes the plate beneath the drive housing; the drawing shows the housing height as 152 mm.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]