NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg
NICE-TOO3000
in stock
€111.32 excluding VAT
€136.92 including VAT

 pcs
Weight
6,00 kg

Description of NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg

NICE TOO3000 is a standalone electromechanical operator for one swing gate leaf up to 3 m and up to 300 kg. The motor is 230 V AC; it is not a 24 V version. It is non-reversible and in the event of a power outage, it is released with a key. Control unit and safety devices are selected based on the complete gate.

Quick navigation
SelectionControl unit
KitsInstallation
Dimension CWiring
TestingAccessories
Manual releaseMaintenance
SpecificationsManual
Accessories – terminals and polarityPDF manual

When to choose this operator

The 3 m and 300 kg limits apply to one leaf, but suitability is not determined by these limits alone. Resistance to movement, hinge position, infill, wind, and installation geometry also matter.

For the 230 V version, the manufacturer specifies a maximum of 24 cycles per hour. For more frequent use, assess the complete gate and whether it is suitable for the duty cycle.

NICE TOO3000 motor dimensions

Control unit for a 230 V motor

Current MC800 with MCA5R30 board controls one or two motors. MC200 is the current option for one motor. For a two-leaf gate, use a suitable control unit for two motors. Our current TOO3000 kits include the MC800; always check the contents of the specific kit before wiring.

For an existing installation with an older control unit, A60, A400, A6 or A6F use the manual for the board actually installed. The MC800 is the current replacement for these control units. Its manual applies to the MC800/MCA5R30. The motor voltage, the control unit's mains supply, and the low-voltage accessory output are separate circuits.

NICE TOO – motor, front and rear brackets

The image shows the motor's main components and brackets. Check the contents of the package before installation. The control unit and safety devices are selected separately or according to the equipment included in the complete kit.

Kits for one or two leaves

The standalone motor is intended for one leaf. A two-leaf gate requires two operators. Compare the 230 V kits with MC800 control units and different equipment on the sides; the standalone 24 V alternative motor is in the center.

Kits for 1 leafKits for 2 leaves

NICE TOO3000
1 × motor, 230 V AC

Basic NICE TOO3000 kit for 1 leaf

MC800 control unit,
receiver and remote control.

Basic kit
No photocells or warning light.

With photocells
Includes photocells.

With accessories
Includes photocells and a warning light.

NICE TOO3000
2 × motor, 230 V AC

Basic NICE TOO3000 kit for 2 leaves

MC800 control unit,
receiver and remote control.

Basic kit
No photocells or warning light.

With photocells
Includes photocells.

With accessories
Includes photocells and a warning light.

Length and weight limits are assessed separately for each leaf, together with the installation geometry. Before use, supplement the basic kit with the required safety devices; see compatible accessories.

Bracket installation and gate-leaf geometry

Before anchoring, determine the positions of the hinge, rear and front brackets, and the required opening angle. Dimensions A/B in the drawing determine the movement path and forces. Both the post and the anchoring must withstand the load; if the hinge position or post size differs, adjust the brackets or use suitable extended brackets to maintain the required geometry. The profile size alone does not guarantee this.

NICE TOO – installation geometry A/B; use the relevant rows for TOO3000

Opening angleAB
90°95 mm270 mm
90°195 mm200 mm
110°150 mm150 mm

For the specific model, see TOO3000 mounting bracket dimensions. For outward opening, different or extended mounting is usually required; check A, B again, C and free movement throughout the full travel path.

Dimension C with the gate closed

With the gate leaf closed, measure the distance C < 1 100 mm. The value must be below the stated limit; it must not equal or exceed it. The selected A/B combination must also be respected.

NICE TOO – measuring installation dimension C with the gate closed

Fasten the rear bracket to the supporting structure, then release it, extend the piston, and initially fit the front bracket as a trial. Once the motor is aligned, check the full manual movement. Only then permanently secure the brackets. In both the open and closed positions, there must be mechanical gate stops; the end of the piston stroke does not replace them.

NICE TOO – fastening the rear bracket

NICE TOO – testing and fastening the front bracket

NICE TOO – manually checking the mechanical stop

Wiring a 230 V motor

Carry out wiring with the power disconnected. Route the cable through the gland and clamp; connect the PE protective conductor to the motor as shown in the drawing. Connect the motor wires and the corresponding capacitor according to the terminals on the specific control board and the component label. For MC800/MCA5R30, connect one motor to M2; with two motors, assign M1/M2 according to the movement sequence. Low-voltage photocells must not be connected to the motor terminals.

For MC800/MCA5R30, see M1/M2 motor wiring and control unit wiring.

NICE TOO 230 V – cable gland and strain relief

Wiring the NICE TOO 230 V motor terminal block and protective conductor

Test before first use

Check that manual movement is unobstructed, the mounting is secure, both stops are in place, and the motor runs in the correct direction. According to NICE, with the drive released, the gate leaf must be movable by hand in both directions using a force of no more than 390 N. Then test the following according to the manual for the installed control unit: photocells, STOP, commands, and response to an obstacle. For an installation with MC800, the manufacturer also requires safety edges; photocells alone do not replace them. The motor itself does not provide radio programming or travel learning; for MC800, see radio controls and gate-leaf travel learning.

If the installed control unit has a force regulator Force-F, do not set it to 100% without a specific reason. If approximately 75% is not sufficient, contact technical support. On the current MC800/MCA5R30, the force is set according to this board's manual; do not apply the trimmer adjustment procedure to it. Force adjustment does not replace measuring and testing the safety of the entire gate.

NICE TOO3000/TOO4500 – Force-F force regulator, approximately 75% rather than 100%

Wiring accessories to MC800 with an MCA5R30 board

The following wiring applies to MC800/MCA5R30 in kits supplied with this control unit. The accessory terminals are on the control unit, not on the motor itself. For a different control unit, use its own wiring diagram. Disconnect the mains power before starting work.

AccessoriesTerminals, power supply and polarity
Auxiliary power supply
On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common point for the inputs. The total current limit for powered accessories is 200 mA; check the current draw and permitted voltage for each product.
EPM relay photocells
With Standby disabled and no photocell test, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Voltage-free contact C–NC of the receiver between 4 (common) and the corresponding input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. AUX inputs must be set to relay photocell mode; in limit-switch mode, they have a different function.
EPM with Standby enabled
According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, maximum 4 W and switches off in Standby; do not use terminal 5 as a permanent negative. The RX C–NC contact connects between terminal 4 and the corresponding PHOTO input.
EPM with photocell testing
Wire according to the photocell test diagram: TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is powered continuously: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the corresponding PHOTO input. Do not overload OutSTB or use it at the same time for another load; after wiring, run the learning procedure and test the safety function.
BlueBUS photocells
Compatible EPMB connect using two wires to BlueBUS terminals 6 and 7. + and − are not polarity-sensitive. Set the address and run device learning after adding or removing a unit.
STOP and command contacts
Voltage-free input 12/STOP accepts the connected device as NO, NC or 8.2 kΩ; the state is learned. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common). These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to the relay of a key switch or external receiver.
ELAC flashing light
NICE ELAC connect to the FLASH output designed for a self-flashing lamp: switched 120/250 V AC, maximum 21 W. This is a mains-voltage output; it has no +/− polarity. Do not confuse it with the 24 V accessory terminals.
Electric lock
Terminals 1–2 / EL: 12 V AC, maximum 15 VA. AC output has no +/− polarity; check the lock specifications.
Radio receiver
OXIBD fits into the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals.

If AUX inputs 8–11 are used for limit switches, their function differs from that of PHOTO inputs. If you change the photocells or wiring, repeat the relevant learning procedure and test the gate's stopping and response. Detailed instructions are in the MC800 control unit manual.

MCA5R30 diagram: relay photocells with Standby enabled, BlueBUS and other terminals
Relay photocells in Standby mode

MCA5R30 diagram: power supply and relay photocell contacts with photocell testing
Relay photocells with photocell testing

Compatible accessories

Accessories connect to the selected control unit, not directly to the motor housing. The choice of photocells, radio receiver, flashing light and lock depends on the outputs and connectors actually fitted to the board.

What Why Type
Control unit

Controls one or two 230 V motors. Choose it according to the number of gate leaves and the gate's equipment.

Flashing light

Flashes to warn that the gate is moving. Choose the power supply to match the output on the installed control unit.

  • ELAC for the 230 V FLASH output on MC800; for MC200, check its output and permitted load.
Photocells

Protect the gate area. MC800/MCA5R30 supports a relay contact as well as BlueBUS, while MC200 has a relay PHOTO input; determine the power supply, addressing and response according to the selected board. The types on the right are alternatives depending on the wiring.

  • Wired relay – EPM
  • Reflective relay – EPMOR
  • Vandal-resistant wired relay – EPMA
  • Wired BlueBUS – EPMB, EPLB, EPSB
  • BlueBUS with reflector- EPMORB
  • BlueBUS wireless - EPMOW
  • BlueBUS wired, adjustable - F210B
  • BlueBUS wireless - FT210B
  • BlueBUS wired - EPMOB
Safety edgesRequired in addition to photocells when using an MC800 control unit. Choose the edge type and connection method according to the STOP input on the installed control board.
Transmitter

Remote control. Choose the coding to match the radio receiver actually installed; matching frequencies alone are not enough. For MC800, see receiver and remote controls.

Receiver

The radio receiver and other interfaces must be compatible with the specific control unit. The SM plug-in module is used with the MC800; for the MC200, check its own radio receiver and connection options.

  • OXIBD for MC800; for older setups, OXI depending on the installed control board and remote controls.
  • Zamel via a suitable command input. NICE BIDIWIFI uses the interface IBT4N; check available functions for the MCA5R30 control board. More Wi-Fi modules or GSM modules select only according to the inputs and power supply of the installed control unit.
Antenna

Improves receiver range; connection depends on the radio module installed.

Keypad

Access by code. EDSWG requires a compatible radio receiver; BlueBUS EDSB is for the MC800 with this interface, not automatically for the MC200.

Key switch

Key-operated command from a fixed location; connect the contact to a suitable command input on the control unit.

  • surface-mounted, with standard cylinder EKS
  • surface-mounted, with European cylinder, EKSEU
  • flush-mounted, with standard cylinder EKSI
  • recessed, with a European profile cylinder EKSIEU
Card Readers

Access by card or key fob. ETPB uses BlueBUS on the MC800; do not connect this type directly to the MC200.

  • ERA Transponder Reader ETPB
Electric Locks

The lock helps keep the gate leaf closed, especially on longer leaves. PLA10/PLA11 are optional; check the power supply and timing against the control unit and the specific gate. For the MC800, see EL output.

Manual release in the event of a power failure

Open the rubber cover, insert the supplied key and turn it 90° clockwise. You can then move the gate manually. To re-engage the lock, move the gate leaf to approximately half-open and turn the key 90° counterclockwise. Check that it is engaged before operating the motor.

NICE TOO – releasing and re-engaging the motor

Maintenance and safety

Have the motor and gate inspected no later than six months after commissioning. With the power disconnected, check the brackets, screws, corrosion, moving parts, stops and safety devices; then perform a function test. Do not use the gate if it is damaged or encounters unusual resistance.

Motor specifications

ParameterValue
Motor modelTOO3000
Motor voltage230 V AC / 50 Hz
Maximum length of one leaf3 m
Maximum weight of one leaf300 kg
Rated / maximum power consumption250 / 340 W
Rated / maximum current1.1 / 1.5 A
Rated / maximum force300 / 2,000 N
Travel speed0.016 m/s
Piston stroke400 mm
Operating limit24 cycles/h
Ingress protection ratingIP54
Operating temperature−20 to +50 °C
Weight of motor only6 kg
Motor dimensions700 × 100 × 177 mm

The values 340 W and 2,000 N are maximum, not rated. The 6 kg weight is for the motor only; the weight of the delivered package may differ.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg

Product: NICE TOO TOO3000 - standalone operator, for one gate leaf up to 3 m/300 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.