NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use
NICE-TO5016P
in stock
€328.12 excluding VAT
€403.59 including VAT

 pcs
Weight
11 kg

Description of NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use

NICE Toona TO5016P is a standalone motor 230 V AC for one gate leaf.

Operating limits: 5 m and 800 kg are not permissible at the same time. At 5 m, the graph allows approximately 250 kg; 800 kg is allowed only up to approximately 1.8 m. Determine suitability using the TO5016P curve for the length and weight of the specific gate leaf.

A standalone motor requires a suitable control unit. Current MC800/MCA5R30 is an option for one or two motors; MC200 is available for one motor. For an older kit, follow the instructions for the control board actually installed.

Quick navigation
AccessoriesLimits
Service lifeInstallation
WiringManual release
SpecificationsMaintenance
Accessories – terminals and polarityPDF manual

  • Non-reversible
  • 230V
  • Slow
  • With a mechanical stop and microswitch; check the end-stop positions on the supplied unit.
  • For higher loads – 3200N

Operating range

Manufacturer's graph for TO5016P: Read the permissible combination of length and weight for one gate leaf from the curve marked TO5016P.

Original NICE graph: TO5016P length and weight curve

Service life and load

For the TO5016P, the NICE supplement gives an approximate range of 50,000 to 150,000 operating cycles. Actual service life depends on the gate leaf's length and weight, resistance to movement, wind, temperature, and maintenance. The specific number of cycles within this range cannot be determined or guaranteed.

Compatible control units

Currently available

  • NICE MC800 – current model for one or two 230 V motors.
  • NICE MC200 – current model for one 230 V motor.

Older compatible control units – discontinued

MC800 replaces the older A60, A400, A6, and A6F models in the current range. For an existing setup, do not use the MC800 manual for an older installed control board.

I. Installing the rear mounting bracket

Bracket mounting: Before installation, measure the hinge offset and dimensions A/B/C according to the installation graph. For a standard steel post, we recommend a 120 × 120 mm. Use a 100 × 100 mm profile only after assessing the post, anchoring, and foundation strength in relation to the gate and wind.

If the graph dimensions do not work, adjust the rear bracket or use the extended PLA6 bracket. When the gate opens outward, an extended rear bracket is required; position it according to the graph and check that the gate leaf moves freely.

Diagram of the NICE Toona operator opening inward Diagram of the NICE Toona operator opening outward
Inward opening diagram Outward opening diagram

Calculate the position of the rear bracket using the graph, from which you can read dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) for the operator to move smoothly in a linear motion.

The example explains how to read the graph. Determine the dimensions for TO5016P using the model-specific installation graph immediately below.

NICE Toona – example showing how to read dimensions C, B, and A from the installation graph

Original NICE installation graph for TO5016 / TO5016P: dimensions A, B, C

Calculation procedure:

  1. Measure the distance C from the diagram
  2. Find the measured value C on the graph, draw a horizontal line, and read B on the adjacent scale.
  3. The intersection with the d.i.l. line gives the maximum opening angle; read A from it by drawing a vertical line.
  4. The manufacturer does not recommend B values below the dashed line t.
  5. If the angle is unsuitable, adjust A and, if needed, B so they are approximately equal; check the gate leaf's full range of movement.

Before attaching the bracket to a post or wall, shorten it to the required length corresponding to dimensions A and B and weld it to the mounting plate.

Cut the bracket to the required length Weld the shortened bracket to the mounting plate
1. Cut the bracket to the required length 2. Weld the shortened bracket to the mounting plate

The supplied rear bracket is 150 mm. Before shortening and welding, check that the resulting dimensions match the drawing.

Before mounting the rear bracket, check that the front bracket will align with the fixed part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.

Difference F = 34 mm.

NICE drawing: bracket height difference F = 34 mm for Toona 4–5

If everything checks out, secure the rear bracket to the post or wall using screws, wall plugs and washers.

Front bracket and mounting height

For TO5016P, the fixed dimension is D = 845 mm. For the measured value A, choose E from the table (E = 845 mm − A). The bracket height difference shown in the NICE drawing is F = 34 mm; check it against the supplied brackets before welding.

A (mm)E (mm)
100745
110735
120725
130715
140705
150695
160685
170675
180665
190655
200645
210635
220625
230615
240605
250595
260585
270575
280565

Motor wiring and connections

Disconnect the power supply before wiring. 230 V AC is the motor voltage; the control unit's power supply and accessory outputs are considered separately. The motor terminals are marked AP / COM / CH and protective earth. Carry out the wiring, direction-of-travel setup and microswitch checks according to the original NICE illustration and the instructions for the control unit in use. For outward opening, NICE specifies swapping the direction wires; leave the protective earth wire in place.

Original illustration of the NICE Toona TO5016P motor terminals

Original NICE wiring diagram for the Toona TO5016P motor

After wiring, check the direction of travel, stop positions and safety devices according to the manual for the control unit in use.

End positions and microswitch

The 230 V motor has a mechanical stop with a microswitch that cuts the power when it contacts the pin. With the power disconnected, check the number and position of the stops on the supplied unit, and test opening and closing according to the instructions for the actual control unit. The procedure for setting the mechanical stop on the 24 V version does not apply to this 230 V motor.

Connecting accessories to the MC800 with the MCA5R30 board

The following wiring applies to MC800/MCA5R30 in kits supplied with this control unit. The accessory terminals are on the control unit, not on the motor itself. If using a different control unit, follow its own wiring diagram. Disconnect the mains power before starting work.

AccessoriesTerminals, power supply and polarity
Auxiliary power supply
On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common input connection. The shared current limit for powered accessories is 200 mA; check the current draw and permitted voltage of each product.
EPM relay photocells
With Standby disabled and no photocell test, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the volt-free C–NC contact of the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. The AUX inputs must be set to relay photocell mode; they have a different function in limit-switch mode.
EPM with Standby enabled
According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, max. 4 W and switches off in Standby; do not use terminal 5 as a permanent negative. Connect the RX C–NC contact between terminal 4 and the corresponding PHOTO input.
EPM with photocell testing
Wire according to the photocell test diagram TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is permanently powered: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the corresponding PHOTO input. Do not overload OutSTB or use it to power another load at the same time; after wiring, perform device learning and test the safety function.
BlueBUS photocells
Compatible EPMB connect using two wires to BlueBUS terminals 6 and 7. There is no polarity distinction between + and −. Set the address and run device learning after adding or removing a device.
STOP and command contacts
Volt-free input 12/STOP accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common). These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to relays for a key switch or external receiver.
ELAC flashing light
NICE ELAC connect to the FLASH output intended for a self-flashing lamp: switched 120/250 V AC, max. 21 W. This is a mains output; it has no +/− polarity. Do not confuse it with the 24 V accessory terminals.
Electric lock
Terminals 1–2 / EL: 12 V AC, max. 15 VA. The AC output has no +/− polarity; check the lock specifications.
Radio receiver
OXIBD is fitted into the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals.

If AUX inputs 8–11 are used for limit switches, their function differs from that of the PHOTO inputs. If you change the photocells or wiring, repeat the relevant learning procedure and test the gate's stopping and response. For detailed instructions, see the MC800 control unit manual.

MCA5R30 diagram: relay photocells with Standby enabled, BlueBUS and other terminals
Relay photocells in Standby mode

MCA5R30 diagram: power supply and relay photocell contacts with photocell testing
Relay photocells with photocell testing

Compatible accessories for the NICE Toona TO5016P operator

Choose accessories according to the actual control unit, its inputs and outputs, and its radio receiver:

What Why Type
Control unit Motor control electronics; choose the manual for the board actually installed.
  • Current: MC800/MCA5R30 for one or two 230 V motors; MC200 for one motor.
  • Older compatible board: MCA5. Use the manual for its own generation.
Flashing light Signals movement. Only models specified by the manufacturer as including an antenna have one. The choice depends on the control unit output.
  • LED flashing light with antenna ELAC

Choose another flashing light according to the voltage and output rating of the actual control unit.

Photocells They monitor the beam path and send a signal to the control unit. The gate response depends on the wiring and settings; test the complete system after installation.
Transmitter Choose a remote control to match the receiver and coding installed in the control unit. ON3EBD is for OXIBD; ON3ELR is for OXILR.
Receiver The radio receiver must support the remote's coding; smart home interfaces have different functions.
  • BiDi-WiFi – Bus-T4 interface for configuration; available control depends on the control board and app.
  • BiDi-ZWave – Z-Wave interface.
  • Wired Wi-Fi module, for example Zamel, connect only to a suitable control input. SUPLA app: Android / iOS.
Antenna Improves receiver reception when correctly positioned and connected.
  •  integrated into the warning light ELAC
  • standalone antenna ABFKIT
Keypad Code access. A BlueBUS keypad requires a control board that supports command devices.
Key switch Control via a suitable control input on the control unit.
  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder, EKSEU
  • recessed, with a standard cylinder EKSI
  • recessed, with a European cylinder EKSIEU
Card readers ETPB requires the specific control board to support command devices on BlueBUS.
  • ERA Transponder Reader ETPB
Electric locks Secures the gate leaf; check the lock's control method and voltage against the control unit and installation.

Manual drive release

Release or lock the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. Disconnect the power supply in the event of a fault.

  1. Slide the protective cover aside, insert the supplied key and turn it clockwise.
  2. Raise the release lever and move the gate leaf manually.
  3. To lock it again, lower the lever, turn the key anticlockwise, remove it and close the cover.

Original NICE image: manual release of the Toona drive

Before restarting, check that the drive is locked and that no one is in the gate's path.

Inspection and maintenance

Have the drive inspected by a professional at least every 6 months; more frequent inspections may be necessary with intensive use. With the power disconnected, check the mounting, corrosion, wear and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and fix the cause of the fault.

Technical specifications

ParameterValue
Model
TO5016P
Drive motor
230 V AC
Maximum / rated current
1.7 A / 1.2 A
Maximum / rated power input
385 W / 220 W
Motor capacitor
12 µF
Stroke
505 mm
No-load speed
0.013 m/s
Loaded speed
0.010 m/s
Maximum / rated force
3,200 N / 800 N
Cycles per hour at rated force
46
Protection rating
IP44
Operating temperature
−20 to +50 °C
Thermal protection
140 °C
Insulation class
F
Estimated service life according to NICE
50,000 to 150,000 operating cycles
Overall dimensions (length × width × height)
965 × 115 × 105 mm
Motor weight
7 kg

The specifications and diagram for the TO5016P model are supplemented by the manufacturer's installation supplement. Program the system according to the instructions for the control unit actually installed.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use

Product: NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.