NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€403.59 including VAT
| Weight |
|---|
| 11 kg |
Description of NICE Toona 5016P – single operator for swing gates with leaves up to 5 m/800 kg, for heavier-duty use
NICE Toona TO5016P is a standalone motor 230 V AC for one gate leaf.
Operating limits: 5 m and 800 kg are not permissible at the same time. At 5 m, the graph allows approximately 250 kg; 800 kg is allowed only up to approximately 1.8 m. Determine suitability using the TO5016P curve for the length and weight of the specific gate leaf.
A standalone motor requires a suitable control unit. Current MC800/MCA5R30 is an option for one or two motors; MC200 is available for one motor. For an older kit, follow the instructions for the control board actually installed.
| Quick navigation | |
|---|---|
| Accessories | Limits |
| Service life | Installation |
| Wiring | Manual release |
| Specifications | Maintenance |
| Accessories – terminals and polarity | PDF manual |
- Non-reversible
- 230V
- Slow
- With a mechanical stop and microswitch; check the end-stop positions on the supplied unit.
- For higher loads – 3200N
Operating range
Manufacturer's graph for TO5016P: Read the permissible combination of length and weight for one gate leaf from the curve marked TO5016P.
Service life and load
For the TO5016P, the NICE supplement gives an approximate range of 50,000 to 150,000 operating cycles. Actual service life depends on the gate leaf's length and weight, resistance to movement, wind, temperature, and maintenance. The specific number of cycles within this range cannot be determined or guaranteed.
Compatible control units
Currently available
- NICE MC800 – current model for one or two 230 V motors.
- NICE MC200 – current model for one 230 V motor.
Older compatible control units – discontinued
MC800 replaces the older A60, A400, A6, and A6F models in the current range. For an existing setup, do not use the MC800 manual for an older installed control board.
I. Installing the rear mounting bracket
Bracket mounting: Before installation, measure the hinge offset and dimensions A/B/C according to the installation graph. For a standard steel post, we recommend a 120 × 120 mm. Use a 100 × 100 mm profile only after assessing the post, anchoring, and foundation strength in relation to the gate and wind.
If the graph dimensions do not work, adjust the rear bracket or use the extended PLA6 bracket. When the gate opens outward, an extended rear bracket is required; position it according to the graph and check that the gate leaf moves freely.
![]() |
![]() |
| Inward opening diagram | Outward opening diagram |
Calculate the position of the rear bracket using the graph, from which you can read dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) for the operator to move smoothly in a linear motion.
The example explains how to read the graph. Determine the dimensions for TO5016P using the model-specific installation graph immediately below.
Calculation procedure:
- Measure the distance C from the diagram
- Find the measured value C on the graph, draw a horizontal line, and read B on the adjacent scale.
- The intersection with the d.i.l. line gives the maximum opening angle; read A from it by drawing a vertical line.
- The manufacturer does not recommend B values below the dashed line t.
- If the angle is unsuitable, adjust A and, if needed, B so they are approximately equal; check the gate leaf's full range of movement.
Before attaching the bracket to a post or wall, shorten it to the required length corresponding to dimensions A and B and weld it to the mounting plate.
![]() |
![]() |
| 1. Cut the bracket to the required length | 2. Weld the shortened bracket to the mounting plate |
The supplied rear bracket is 150 mm. Before shortening and welding, check that the resulting dimensions match the drawing.
If everything checks out, secure the rear bracket to the post or wall using screws, wall plugs and washers.
Front bracket and mounting height
For TO5016P, the fixed dimension is D = 845 mm. For the measured value A, choose E from the table (E = 845 mm − A). The bracket height difference shown in the NICE drawing is F = 34 mm; check it against the supplied brackets before welding.
| A (mm) | E (mm) |
|---|---|
| 100 | 745 |
| 110 | 735 |
| 120 | 725 |
| 130 | 715 |
| 140 | 705 |
| 150 | 695 |
| 160 | 685 |
| 170 | 675 |
| 180 | 665 |
| 190 | 655 |
| 200 | 645 |
| 210 | 635 |
| 220 | 625 |
| 230 | 615 |
| 240 | 605 |
| 250 | 595 |
| 260 | 585 |
| 270 | 575 |
| 280 | 565 |
Motor wiring and connections
Disconnect the power supply before wiring. 230 V AC is the motor voltage; the control unit's power supply and accessory outputs are considered separately. The motor terminals are marked AP / COM / CH and protective earth. Carry out the wiring, direction-of-travel setup and microswitch checks according to the original NICE illustration and the instructions for the control unit in use. For outward opening, NICE specifies swapping the direction wires; leave the protective earth wire in place.
After wiring, check the direction of travel, stop positions and safety devices according to the manual for the control unit in use.
End positions and microswitch
The 230 V motor has a mechanical stop with a microswitch that cuts the power when it contacts the pin. With the power disconnected, check the number and position of the stops on the supplied unit, and test opening and closing according to the instructions for the actual control unit. The procedure for setting the mechanical stop on the 24 V version does not apply to this 230 V motor.
Connecting accessories to the MC800 with the MCA5R30 board
The following wiring applies to MC800/MCA5R30 in kits supplied with this control unit. The accessory terminals are on the control unit, not on the motor itself. If using a different control unit, follow its own wiring diagram. Disconnect the mains power before starting work.
| Accessories | Terminals, power supply and polarity |
|---|---|
Auxiliary power supply | On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common input connection. The shared current limit for powered accessories is 200 mA; check the current draw and permitted voltage of each product. |
EPM relay photocells | With Standby disabled and no photocell test, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the volt-free C–NC contact of the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. The AUX inputs must be set to relay photocell mode; they have a different function in limit-switch mode. |
EPM with Standby enabled | According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, max. 4 W and switches off in Standby; do not use terminal 5 as a permanent negative. Connect the RX C–NC contact between terminal 4 and the corresponding PHOTO input. |
EPM with photocell testing | Wire according to the photocell test diagram TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is permanently powered: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the corresponding PHOTO input. Do not overload OutSTB or use it to power another load at the same time; after wiring, perform device learning and test the safety function. |
BlueBUS photocells | Compatible EPMB connect using two wires to BlueBUS terminals 6 and 7. There is no polarity distinction between + and −. Set the address and run device learning after adding or removing a device. |
STOP and command contacts | Volt-free input 12/STOP accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common). These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to relays for a key switch or external receiver. |
ELAC flashing light | NICE ELAC connect to the FLASH output intended for a self-flashing lamp: switched 120/250 V AC, max. 21 W. This is a mains output; it has no +/− polarity. Do not confuse it with the 24 V accessory terminals. |
Electric lock | Terminals 1–2 / EL: 12 V AC, max. 15 VA. The AC output has no +/− polarity; check the lock specifications. |
Radio receiver | OXIBD is fitted into the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals. |
If AUX inputs 8–11 are used for limit switches, their function differs from that of the PHOTO inputs. If you change the photocells or wiring, repeat the relevant learning procedure and test the gate's stopping and response. For detailed instructions, see the MC800 control unit manual.

Relay photocells in Standby mode

Relay photocells with photocell testing
Compatible accessories for the NICE Toona TO5016P operator
Choose accessories according to the actual control unit, its inputs and outputs, and its radio receiver:
| What | Why | Type |
|---|---|---|
| Control unit | Motor control electronics; choose the manual for the board actually installed. |
|
| Flashing light | Signals movement. Only models specified by the manufacturer as including an antenna have one. The choice depends on the control unit output. |
Choose another flashing light according to the voltage and output rating of the actual control unit. |
| Photocells | They monitor the beam path and send a signal to the control unit. The gate response depends on the wiring and settings; test the complete system after installation. | |
| Transmitter | Choose a remote control to match the receiver and coding installed in the control unit. ON3EBD is for OXIBD; ON3ELR is for OXILR. | |
| Receiver | The radio receiver must support the remote's coding; smart home interfaces have different functions. |
|
| Antenna | Improves receiver reception when correctly positioned and connected. | |
| Keypad | Code access. A BlueBUS keypad requires a control board that supports command devices. | |
| Key switch | Control via a suitable control input on the control unit. | |
| Card readers | ETPB requires the specific control board to support command devices on BlueBUS. |
|
| Electric locks | Secures the gate leaf; check the lock's control method and voltage against the control unit and installation. |
|
Manual drive release
Release or lock the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. Disconnect the power supply in the event of a fault.
- Slide the protective cover aside, insert the supplied key and turn it clockwise.
- Raise the release lever and move the gate leaf manually.
- To lock it again, lower the lever, turn the key anticlockwise, remove it and close the cover.
Before restarting, check that the drive is locked and that no one is in the gate's path.
Inspection and maintenance
Have the drive inspected by a professional at least every 6 months; more frequent inspections may be necessary with intensive use. With the power disconnected, check the mounting, corrosion, wear and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and fix the cause of the fault.
Technical specifications
| Parameter | Value |
|---|---|
Model | TO5016P |
Drive motor | 230 V AC |
Maximum / rated current | 1.7 A / 1.2 A |
Maximum / rated power input | 385 W / 220 W |
Motor capacitor | 12 µF |
Stroke | 505 mm |
No-load speed | 0.013 m/s |
Loaded speed | 0.010 m/s |
Maximum / rated force | 3,200 N / 800 N |
Cycles per hour at rated force | 46 |
Protection rating | IP44 |
Operating temperature | −20 to +50 °C |
Thermal protection | 140 °C |
Insulation class | F |
Estimated service life according to NICE | 50,000 to 150,000 operating cycles |
Overall dimensions (length × width × height) | 965 × 115 × 105 mm |
Motor weight | 7 kg |
The specifications and diagram for the TO5016P model are supplemented by the manufacturer's installation supplement. Program the system according to the instructions for the control unit actually installed.