NICE Toona TO4016P is a standalone electromechanical motor for one gate leaf. The motor operates at 230 V AC from a suitable control unit. The motor voltage is not the same as the control unit's mains supply voltage.

Assess the weight and length of a single leaf together using the NICE graph; the two limit values listed for the model do not automatically apply at the same time.

The reinforced version has its own graph showing the allowable leaf weight and length. Use the graph for the exact motor model when selecting a motor.

If the motor is part of a kit with MC800/MCA5R30, use the manual for this control board. For a different or older kit, check the actual control unit model.

Quick navigation
AccessoriesLimits
Service lifeInstallation
WiringManual release
SpecificationsMaintenance
Accessories – terminals and polarityPDF manual

  • Non-reversible
  • 230V
  • Slow
  • With a mechanical stop and microswitch; check the limit positions against the actual motor configuration
  • For heavier loads – 3200N

Application range

The NICE graph shows limit values of 800 kg and 3 m for a single leaf. Read the allowable combination from the curve; the maximum values cannot automatically be used at the same time.

Original NICE graph: allowable weight and length of the TO4016P leaf

Service life and load

For the TO4016P model, the estimated service life is 50,000 to 150,000 operating cycles. It depends on the leaf's weight and length, resistance to movement, temperature, wind, and maintenance. The exact number of cycles for a specific gate cannot be determined from this range.

Choosing a control unit

NICE MC800/MCA5R30 is the current control unit and replaces the older A60, A400, A6, and A6F models. The MC200 is also still available for one motor. If an older control unit is already installed, use the manual for its actual circuit board.

Currently available

Older compatible control units – discontinued

I. Installing the rear mounting bracket

Post and bracket mounting: For a standard installation, we recommend a sturdy post with a cross-section of 120 × 120 mm. A cross-section of 100 × 100 mm is a guideline minimum, provided the strength of the post and its foundation, as well as the hinge position, are suitable.

For a different cross-section or hinge offset, adjust the rear bracket or use the extended PLA6 bracket. Dimensions A and B must match the measured C and the opening angle; their meaning is shown in the installation graph. Opening outwards requires an extended rear bracket; determine its length from the installation geometry and check that the leaf can move freely.

Diagram of the NICE Toona operator opening inward
Inward opening diagram

Diagram of the NICE Toona operator opening outward
Outward opening diagram

Calculate the position of the rear bracket using the graph, which shows the dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) to allow the operator to move smoothly in a linear motion.

NICE Toona TO4006 / TO4016P installation graph
NICE Toona TO4006 / TO4016P installation graph

Illustration of how to calculate the NICE Toona operator installation dimensions 
Example of reading values from the graph

Calculation procedure:

  1. Measure the distance C from the diagram
  2. Find the measured C in the installation graph and draw a horizontal line from it. Read the corresponding dimension B from the adjacent scale.
  3. The intersection with the d.i.l. line (the recommended installation line on the NICE graph) determines the maximum opening angle; read dimension A vertically from that point.
  4. Do not use dimension B below the dashed t line; NICE does not recommend this area of the graph.
  5. If the opening angle is unsuitable, adjust A and, if necessary, B so that they are approximately equal. Then check the full movement of the leaf again.

Before attaching the bracket to a post or wall, it must be shortened to the required length corresponding to dimensions A and B and weld it to the mounting plate.

Cut the bracket to the required length
1. Cut the bracket to the required length

Weld the shortened bracket to the mounting plate
2. Weld the shortened bracket to the mounting plate

The supplied rear bracket is 150 mm long. Before shortening and welding it, check that it allows you to maintain dimensions A and B for your post; use an extended bracket if necessary.

Before attaching the rear bracket, check that the front bracket will be positioned on the fixed part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.

According to the NICE drawing, the height difference between the brackets is F = 34 mm. Check the dimension on the supplied brackets as well before welding.

NICE Toona: F = 34 mm for series 4–5, F = 50 mm for series 6–7

If everything checks out, attach the rear bracket to the post or wall using screws, wall plugs and washers.

II. Installing the front mounting bracket

Position the front bracket according to dimensions A, D and E. For TO4016P, the installation table specifies D = 695 mm; select the corresponding value of E based on the measured value of A:

A (mm)E (mm)
100595
110585
120575
130565
140555
150545
160535
170525
180515
190505
200495
210485

The package includes a bracket for welding. If you would prefer a bolt-on bracket, we recommend ordering the alternative NICE PLA8 bolt-on bracket.

  1. Calculate from the table the value of E
  2. Calculate the height according to the illustration bracket heights (view illustration)
  3. Attach the bracket to the gate leaf (if welding the bracket, we recommend tack-welding it for now)

III. Installing the gate operator on the rear bracket

Installing the NICE Toona operator on the rear bracket

  1. Attach the motor to the bracket as shown in the illustration, using the supplied rear-bracket pin, washer and nut.
  2. Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can pivot

IV. Installing the gate operator on the front bracket

Installing the NICE Toona operator on the front bracket

  1. Attach the operator to the bracket as shown in the illustration, using the supplied pin and washer.
  2. Tighten the pin fully

V. Limit positions and microswitch

The 230 V motor has a mechanical stop with a microswitch that cuts off power to the motor when it comes into contact with the pin. With the power disconnected, check the actual limit-stop configuration of the supplied operator, set the limit positions, and test movement and safety devices before operation, following the instructions for the control unit being used.

Motor wiring and connections

Disconnect the power supply before wiring. 230 V AC is the motor voltage; the control unit's supply and accessory outputs must be assessed separately. The motor terminals are labelled AP / COM / CH and protective earth. Make the connections, set the direction of movement and check the microswitches according to the original NICE illustration and the instructions for the control unit being used. For outward opening, NICE specifies swapping the direction wires; the protective earth wire remains in place.

Original illustration of the NICE Toona TO4016P motor terminals

Original NICE wiring diagram for the Toona TO4016P motor

After wiring, check the direction of movement, stop positions and safety devices according to the manual for the specific control unit.

Accessory wiring for the MC800 with MCA5R30 board

The following wiring applies to the MC800/MCA5R30 in kits with this control unit. The accessory terminals belong to the control unit, not the motor itself. For a different control unit, use its own wiring diagram. Disconnect the mains supply before starting work.

AccessoriesTerminals, power supply and polarity
Auxiliary power supply
On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common input connection. The shared current limit for powered accessories is 200 mA; check the current draw and permitted voltage of each product.
EPM relay photocells
With Standby disabled and no photocell test, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the voltage-free contact C–NC of the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/−. The AUX inputs must be set to relay photocell mode; in limit switch mode, they have a different function.
EPM with Standby enabled
According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, max. 4 W, and switches off in Standby; do not use terminal 5 as a permanent negative. Connect the RX C–NC contact between terminal 4 and the relevant PHOTO input.
EPM with photocell test
Wire according to the photocell test diagram: TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is powered continuously: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the relevant PHOTO input. Do not overload OutSTB or use it at the same time for another load; after wiring, run the learning procedure and test the safety function.
BlueBUS photocells
Compatible EPMB connect with two wires to BlueBUS terminals 6 and 7. + and − are not polarity-sensitive. Set the address and run device learning after adding or removing a device.
STOP and command contacts
Voltage-free input 12/STOP accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact against terminal 4 (common). These contacts have no +/−; do not apply an external voltage to the inputs. This also applies to key switch or external receiver relays.
ELAC beacon
NICE ELAC connect to the FLASH output, intended for a self-flashing lamp: switched 120/250 V AC, max. 21 W. This is a mains output; it has no +/−. Do not confuse it with the 24 V accessory terminals.
Electric lock
Terminals 1–2 / EL: 12 V AC, max. 15 VA. The AC output has no positive or negative polarity; check the lock specifications.
Radio receiver
OXIBD is installed in the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals.

If AUX inputs 8–11 are used for limit switches, their function differs from that of the PHOTO inputs. If you change the photocells or wiring, repeat the relevant learning procedure and test the gate's stopping and response. Detailed instructions are in the MC800 control unit manual.

MCA5R30 diagram: relay photocells with Standby enabled, BlueBUS and other terminals
Relay photocells in Standby mode

MCA5R30 diagram: power supply and relay photocell contacts with photocell test
Relay photocells with photocell test

Accessories by control unit

Choose optional accessories according to the control unit in the specific setup. Before ordering, check its voltage, inputs, receiver and connection type:

What Why Type
Control unit

The drive's control electronics.

Beacon Signals gate movement. The ELAC model has a built-in antenna; when connected correctly, it can improve remote control reception.
  • LED beacon with antenna ELAC

Choose another beacon according to the voltage and load rating of the actual control unit output.

Photocells

Photocells help detect obstacles; the gate's response depends on the wiring and control unit settings.

For the MC800, wired-contact and BlueBUS photocells connect to different inputs. Determine the number of pairs and how to use them based on the actual board.

  • Wired relay photocells - EPM
  • Reflector relay photocells - EPMOR
  • Anti-vandal wired relay photocells - EPMA
  • Wired BlueBUS photocells - EPMB, EPLB, EPSB
  • Reflector BlueBUS photocells - EPMORB
  • Wireless BlueBUS photocells - EPMOW
  • Adjustable wired BlueBUS photocells - F210B
  • Wireless BlueBUS photocells - FT210B
  • Wired BlueBUS photocells - EPMOB
Transmitter For remote gate control.

Choose the remote control type and coding according to the receiver installed in the control unit being used.

Receiver

For remote control of the gate.

Before choosing, check the connector and the coding supported by the specific control board.

  • BiDi-WiFi – Bus-T4 interface for configuring the automation system; control functions depend on the control board and the app used.
  • BiDi-ZWave – interface for the Z-Wave system; check support for the specific control board before choosing.
  • Wired Wi-Fi module, for example Zamel, connect only to a suitable control input on the control unit. SUPLA app: Android / iOS.
  • GSM receivers: GSM modules with a suitable control contact should be connected according to the input on the control unit used.
Antenna

For improved remote-control range.

  •  integrated into the warning light ELAC
  • standalone antenna ABFKIT
Keypad Open the gate using a code, without a remote control. For BlueBUS models, check whether the actual control unit supports them as control devices.
Key switch Key-operated control via a suitable control input on the control unit; choose the installation location according to the wiring.
  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder, EKSEU
  • flush-mounted, with a standard cylinder EKSI
  • flush-mounted, with a European cylinder EKSIEU
Card readers Access using a card or key fob. ETPB requires a control unit with BlueBUS that supports control devices.
  • ERA Transponder Reader ETPB
Electric locks An electric lock secures the gate leaf in the closed position. Check the lock's suitability and control requirements for the gate, voltage, and output of the control unit used.

Manual operator release

Release or lock the operator only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. In the event of a fault, disconnect the power supply.

  1. Slide the protective cover aside, insert the supplied key, and turn it clockwise.
  2. Lift the release lever and move the gate leaf manually.
  3. To lock it again, lower the lever, turn the key counterclockwise, remove it, and close the cover.

Original NICE image: manual release of the Toona operator

Before restarting, check that the operator is locked and that no one is in the gate's path.

Inspection and maintenance

Have the operator professionally inspected at least every 6 months; more frequent inspections may be necessary with intensive use. With the power disconnected, check the fastenings, corrosion, wear, and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and resolve the cause of the fault.

Technical specifications

ParameterValue
Model
TO4016P
Drive motor
230 V AC
Maximum / rated current draw
1.7 A / 1.2 A
Maximum / rated power consumption
385 W / 220 W
Motor capacitor
12 µF
Stroke
350 mm
No-load speed
0.013 m/s
Speed under load
0.010 m/s
Maximum / rated force
3,200 N / 800 N
Cycles per hour at rated force
46
Protection rating
IP44
Operating temperature
−20 to +50 °C
Thermal protection
140 °C
Insulation class
F
Estimated service life according to NICE
50,000 to 150,000 operating cycles
Overall dimensions (length × width × height)
820 × 115 × 105 mm
Motor weight
6 kg

NICE Toona installation manual · Technical supplement for TO4016P. Programming, position learning and accessories are covered in the manual for the actual control unit.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Toona Toona 4016P - standalone operator for swing gates with leaves up to 3 m/800 kg, for heavier-duty use

Product: NICE Toona Toona 4016P - standalone operator for swing gates with leaves up to 3 m/800 kg, for heavier-duty use
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.