NICE Wingo WG5000 - standalone operator for swing gates with a leaf up to 3.5 m/500 kg
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€289.38 including VAT
| Weight |
|---|
| 8,40 kg |
Description of NICE Wingo WG5000 - standalone operator for swing gates with a leaf up to 3.5 m/500 kg
NICE WINGO WG5000 is a standalone electromechanical operator for one gate leaf at a residential property. It has a 230 V AC / 50 Hz motor, a worm gear and a pre-installed mechanical opening stop. It is non-reversible; in the event of a power failure, it can be released with a key. Choose the control unit separately, based on the number of motors and the gate equipment.
When to choose NICE WINGO WG5000
This operator is designed for residential swing gates. Before choosing, assess the length and weight of one leaf, its infill, wind exposure, hinge resistance and the space available for the brackets. The gate must move smoothly by hand along its entire travel and must not start moving by itself after it stops.
| Maximum leaf length | 3.5 m; the permissible weight varies according to the graph. |
|---|---|
| Maximum leaf weight | 500 kg for a shorter leaf—not automatically at the maximum length. |
| Motor and control | 230 V AC motor, separate control unit; MC800 for one or two motors. |
| Application | Residential use, up to 30 cycles/hour at rated force and under suitable conditions. One cycle consists of opening and closing. |
The horizontal axis shows length in metres, and the vertical axis shows weight in kilograms. Choose a combination within the grey area. At 3.5 m, the limit is approximately 200 kg; 500 kg applies to a leaf up to approximately 1 m long. Points A and B illustrate a suitable and an unsuitable combination; they are not bracket installation dimensions. A solid gate leaf and strong winds may further limit suitability.
What is included with the standalone operator
This product listing is for one WG5000 motor, not a complete two-leaf gate automation system. The motor comes with a front bracket, a rear bracket with mounting plate, fasteners, release keys and a pre-installed opening stop. Anchors for the specific post or wall must be selected to suit the substrate.
Choose the control unit, receiver, remote controls, photocells and warning light separately or as part of a suitable kit. The gate must have a fixed closing stop. Two motors are required for a two-leaf gate.
Kits for one- or two-leaf gates
All the kits listed include an MC800, an OXIBD receiver and one INTI2 remote control. The basic kit does not include photocells; the photocell version adds a pair of EPM, while the accessories version also includes a warning light, ELAC. The number of motors matches the number of gate leaves.
| Gate | Kit |
|---|---|
| 1 leaf | Basic |
| 1 leaf | With accessories |
| 1 leaf | With photocells |
| 2 leaves | Basic |
| 2 leaves | With accessories |
| 2 leaves | With photocells |
Choosing a control unit
Current control unit NICE MC800 / MCA5R30 controls one or two 230 V motors and replaces older control units for these configurations. For a single motor, an alternative is the NICE MC200 with its own wiring and functions.
Older compatible control units that have since been replaced: NICE Mindy A60, NICE A400, NICE-A6, NICE-A6F. If retaining them, use the manual for the board actually installed. Older MCA5 board and the newer MCA5R30 differ in both terminals and functions; the MC800 designation alone does not identify the generation.
The detailed steps below apply to MC800 with an MCA5R30 board and OutSTB output. They are not instructions for setting up the A60, A6 or MC200.
I. Installing the rear bracket
Disconnect the power supply before starting work. The brackets must be securely anchored, and there must be enough space for the motor to complete its full travel, for the cover to open and for the drive to be released. The drive will not fix a gate that sticks or is incorrectly hung.
A motors, B photocells, C opening stops, D photocell posts, E warning light, F control device, G control unit. The specific safety devices should be selected according to the risks posed by the gate.
- Measure dimension C, i.e. the offset of the hinge axis from the mounting surface, as shown in the diagram.
- Find the measured value of C on the chart. The horizontal line gives dimension B; for the recommended installation line r.i.l. / DIL read off the opening angle.
- From the selected point, draw a vertical line to axis A. A and B should be similar, ideally identical.
- If the angle is unsuitable, choose another permissible A/B combination. Do not use dimensions outside the chart area.
- Before anchoring, check that the front bracket will fit on a solid part of the gate leaf and that the height difference between the brackets will be F = 30 mm.
Shorten the rear bracket as required for A/B and weld it to the mounting plate; then anchor the plate using suitable screws, washers and anchors. The supplied rear bracket is 150 mm. If the geometry requires a longer bracket, use the NICE PLA6 extension bracket; changing its length alone does not replace calculating the dimensions from the chart.
Complete dimensions of GAP02600 mounting brackets will help you check the available mounting space. Check dimensions A/B/C against the hinge position and motor model.
Outward opening
WINGO can also be installed for outward opening, as shown in the following diagram. Allow for the extended rear bracket PLA6 and check the clearance outside the vehicle passage. Adjust the direction of the motor wires to suit the wiring, then check the correct gate-leaf sequence again. The common wire and protective PE must not be interchanged.
II. Front bracket and installation dimensions
For WG5000, D = 850 mm. Select dimension E according to A in the table. D is the installation dimension shown in the diagram; the piston rod stroke is a different value. Weld the bracket to a solid part of the gate leaf; an alternative for bolted installation is the NICE PLA8.
| A (mm) | E (mm) |
|---|---|
| 100 | 750 |
| 110 | 740 |
| 120 | 730 |
| 130 | 720 |
| 140 | 710 |
| 150 | 700 |
| 160 | 690 |
| 170 | 680 |
| 180 | 670 |
| 190 | 660 |
| 200 | 650 |
| 210 | 640 |
| 220 | 630 |
| 230 | 620 |
| 240 | 610 |
| 250 | 600 |
| 260 | 590 |
| 270 | 580 |
| 280 | 570 |
The front attachment on the gate leaf is F = 30 mm lower than the rear attachment on the post, as shown in the diagram. This does not mean the entire motor is tilted: check that it is correctly installed using a spirit level. Before welding, check both motor positions and make sure the bracket on the gate leaf is within reach.
III. Mounting the motor
- Secure the motor to the rear bracket using the supplied bolt, washer and nut. Tighten the nut, then loosen it by approximately 1/10 of a turn, leaving the minimum clearance required.
- Attach the front section to the bracket using the supplied parts and tighten as shown in the diagram.
- Manually test the full travel, checking for any binding or lateral strain. Attach the release procedure label near the drive.
IV. Adjusting the mechanical stop
The pre-installed stop mechanically determines the open position; it is not an electrical limit switch. Ensure the gate has a solid stop when closed. MC800 requires mechanical stops in both directions.
- Disconnect the power and release the motor.
- Loosen the mechanical stop screw.
- Open the gate leaf manually to the required position.
- Slide the stop up to the pin and tighten the screw. Observe the dimension 90 mm max. shown in the stop adjustment detail. This is not the motor's total stroke; for the WG5000, that is 470 mm.
- Close the gate leaf manually and engage the drive. Then run the learning procedure and test the complete system.
Manual release during a power failure
- Stop the gate, disconnect the power and secure the gate leaf against unintended movement. If an electric lock is installed, unlock it first.
- Slide the lock's protective cover aside, insert the key and turn it clockwise.
- Lift the release handle, guiding it as it moves. You can now move the gate leaf manually.
- Before operating the gate automatically, lower the handle, turn the key counterclockwise, remove it and close the protective cover. Check that the drive is engaged.
If the gate is the only entrance to the property, plan access to the release mechanism before installation. If a fault occurs, do not continue automatic operation until you have identified the cause.
Wiring
The following cable cross-sections and lengths apply to a system with MC800/MCA5R30. Keep mains and motor cables separate from low-voltage signals, protect them from water and gate-leaf movement, and secure them in the cable glands. The power supply must have suitable overcurrent protection and a means of complete disconnection.
| Circuit | Cable | Length for MC800 |
|---|---|---|
| Power supply to control unit | 3 × 1.5 mm² | Up to 30 m; for longer runs, use 3 × 2.5 mm² and protective earthing at the automation system as specified in the manual. |
| Each 230 V motor | 4 × 1.5 mm² | Up to 10 m, including the protective PE conductor. |
| ELAC flashing light | 2 × 1.5 mm² | Up to 20 m. |
| BlueBUS photocells | 2 × 0.5 mm² | Up to 20 m; for runs over 20 m and up to 40 m, use 2 × 1 mm²; polarity-independent. |
| Key switch | 2 cables, each 2 × 0.5 mm² | Up to 50 m. |
| Electric lock | 2 × 1 mm² | Up to 10 m. |
| Antenna | RG58 | Up to 20 m; less than 5 m is recommended. |
EPM relay photocells require both power and a signal contact; the number of wires depends on the TX/RX configuration and the test method selected. Complete MC800 wiring and installation.
Motor wiring and accessory polarity
The WG5000 is a 230 V AC motor. Do not connect it to the 24 V motor output of the MC424L or MC824H. Connect the motor wires for open / common / close and the protective PE in accordance with the markings on the motor and control unit. This is an AC circuit, not a +/− polarity connection. The motor has no separate encoder wire or electrically isolated limit switches.
When using one motor with the MC800, use M2. With two motors, M2 opens first and M1 closes first. To reverse the direction, swap the two direction wires of the relevant motor; leave the common wire and PE connected to their designated terminals. Disconnect the power before making any wiring changes.
| 3 / 4 – auxiliary power supply | 3 = 0 V (−), 4 = Common +24 V DC (+), total max. 200 mA. |
|---|---|
| 5 / 3 – OutSTB | 5 = +24 V, 3 = −, switched photocell power supply, max. 4 W. Switched off in Standby; do not confuse it with the OGI terminal on older boards. |
| 6 / 7 – BlueBUS | Two-wire power and data; no +/− polarity. |
| FLASH | Self-flashing light 230 V AC, max. 21 W, for example, ELAC. Do not connect the low-voltage ELDC to this output. |
| 1 / 2 – ELS | Electric lock 12 V AC, max. 15 VA; no DC polarity. |
| 4 / 13 – SbS | Voltage-free NO step-by-step contact; do not apply an external voltage to it. |
| 4 / 14, 4 / 15 | Voltage-free NO contacts: open / close. |
| 4 / 12 – STOP | Learned safety input: NO, NC, or 8.2 kΩ, depending on the safety device wiring. |
| 8 / 9 / 10 – AUX | In relay photocell mode: PHOTO / PHOTO1 / PHOTO2, common contact 4; LP lit. Input 11 is STOP in this mode. Unused AUX terminals remain unconnected; do not add universal jumpers. |
The board has the buttons Open ▲, Stop/Set, and Close ▼, LEDs L1–L8 and the AUX PRG. The receiver fits into the SM connector. Detailed wiring for each terminal.
Photocells, testing, and safety edges
MC800/MCA5R30 supports both relay and BlueBUS photocells, including combined wiring. The AUX mode for relay photocells cannot be used together with AUX for electric limit switches; WINGO does not provide these on AUX. The TX/RX power supply wiring must match the Standby or photocell test mode.
The diagram shows combined wiring without photocell testing, Standby disabled. For a different mode, use its specific diagram; simply changing one jumper is not enough. For EPM with DC power, the following applies: TX/RX 1 = +, 2 = −; RX 4 = COM, 5 = NC. The COM/NC contact goes between 4 Common and the selected PHOTO input 8, 9, or 10. Relay photocells, photocell testing, and Standby.
Connect BlueBUS photocells in parallel using two wires, with no polarity. The TX and RX of each pair must have the same address; different pairs must have different addresses. After changing the wiring, run device recognition again. Addressing and responses of BlueBUS photocells.
Sensitive safety edges are required for an automation system with MC800. Select their type and position based on pinch points and test results. Photocells protect only the area they actually monitor. Connecting safety devices to STOP.
First startup with MC800 / MCA5R30
Before switching on, check that the unit is securely mounted, the release mechanism is secured, stops and guides are in place, motor directions and M1/M2 assignment are correct, and all safety devices are connected. Keep the gate area clear during the first movement, and be ready to stop it.
- After switching on, BlueBUS should flash approximately once per second; the LEDs on connected BlueBUS TX/RX units should flash, and FLASH should be off. If these conditions are not met, first correct the wiring fault.
- Device recognition: hold Open ▲ + Stop/Set and release when L1/L2 start flashing rapidly, after approximately 3 s. On successful completion, STOP stays lit and L1/L2 turn off. Perform this procedure even if no accessories are installed.
- Automatic position learning: hold Stop/Set + Close ▼ and release when L3/L4 flash rapidly, after approximately 3 s. The sequence is: close M1, close M2, open M2, open M1, then close M1 and M2 to their respective stops. With one motor, only M2 operates.
- If the motor opens instead of closing during the first movement, interrupt learning using the Open or Close button. Disconnect the power, correct the direction, and repeat the learning procedure from the beginning. For a double-leaf gate with the leaves in the opposite order, correct the M1/M2 assignment. Leave a single motor on M2; if the direction is wrong, correct only its direction wires.
- Successful position learning is confirmed when L3/L4 go out. If a photocell or STOP device is triggered, learning is interrupted; resolve the cause and repeat the entire procedure.
- Test repeated opening, closing, and stopping; each safety device; leaf overlap; and the release mechanism. Measure the forces of the complete assembly. Put the gate into service only after it has passed testing.
When testing the WINGO unit alone, manual movement must be possible with a force of no more than 390 N. This is the maximum test limit, not a target for a gate that moves stiffly or a setting for impact force. Assess forces during automatic movement using a separate measurement.
Settings and controls
The standalone motor has no programming buttons or radio receiver. Force, pause time, automatic closing, deceleration, and leaf delay are set on the installed control unit. Repeat the tests after changing safety parameters. WINGO is electromechanical; do not enable pressure-holding for hydraulic motors.
MC800 programming and tables · Manual and mixed position learning
When pairing a remote control, the specific receiver and its stored coding matter—not just the frequency. Current kits include OXIBD and INTI2. The bidirectional ON3EBD requires a supported OXIBD; ON3ELR is for OXILR. Connect the OXIBD external antenna directly to the receiver as instructed in its manual; do not automatically connect it to the control board antenna input shown in an older diagram.
Pairing and deleting remote controls
What to check if there is a problem
| Symptom | What to check |
|---|---|
| Motor does not move | Power supply, release mechanism secured, STOP, and photocells. Check fuses and electrical circuits with the power switched off. |
| Motor runs, but the leaf does not move | Release mechanism secured, bracket connections, and mechanical damage. |
| The leaf stops or reverses | First check manual movement, hinges, stops, and obstructions; then check the photocells and safety settings. Do not increase the force without identifying the cause. |
| Incorrect direction or sequence | Direction wires and, for two motors, the M1/M2 assignment. A single motor must remain on M2; do not swap the common wire or PE. |
| Remote control does not respond, but the button does | Battery, compatibility, remote control programming, and receiver antenna. |
| Error after replacing an accessory | Wiring, power supply, AUX or BlueBUS addresses, and running device recognition again. |
Flash counts and repair procedures: MC800 diagnostics. Resetting the control unit, deleting the receiver memory, and position learning are separate procedures. Before resetting, record the settings and follow your control board's instructions.
Compatible accessories
Choose accessories based on the actual control unit, its outputs and the receiver installed.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors, depending on the model selected. |
|
| Warning light | Signals movement. The voltage must match the control unit's output. |
|
| Photocells | Monitor the selected gate area. The MC800/MCA5R30 allows relay and BlueBUS photocells to be combined according to the wiring diagram. | |
| Remote control | For remote operation of the gate. | |
| Receiver | Choose the radio receiver according to the remote controls' coding. Smart control requires a specific compatible interface and power supply. |
|
| Antenna | Improves reception for the compatible receiver; follow its wiring instructions. | |
| Keypad | Gate control via a compatible receiver or decoding interface; the data device itself is not a direct NO contact. | |
| Key switch |
For key-operated gate control via a switch wired to the drive from any location. |
|
| Card readers | Gate control via a compatible receiver or decoding interface; the data device itself is not a direct NO contact. |
|
| Electric locks | Additional leaf locking, depending on the design and load; the MC800 ELS output is 12 V AC / 15 VA. |
|
Estimated service life
Add the relevant weight and length indices, then include the other influencing factors. Use only one applicable row for each weight or length category. Use the total percentage to estimate the number of cycles from the chart.
| Characteristics of the complete automation system | Index | Service life chart |
|---|---|---|
| Gate leaf weight | over 100–200 kg → 0% over 200–300 kg → 10% over 300–400 kg → 20% over 400–500 kg → 30% | |
| Gate leaf length | 1–2 m → 0% over 2–3 m → 10% over 3–3.5 m → 20% | |
| Temperature / humidity | Above +40 °C or below 0 °C, or humidity above 80% → 20% | |
| Solid gate leaf | 15% | |
| Windy location | 15% |
The chart provides an estimate assuming regular maintenance; it does not guarantee a number of years or cycles. It cannot be used as a substitute for the chart of permissible gate leaf weight and length. Assess the operating load and safety requirements for the complete gate.
Maintenance and safe use
At least every 6 months have the fasteners, brackets, hinges, wear, corrosion, screw lubrication, stops, release mechanism and wiring checked. After maintenance, test the gate movements and all safety devices again. For intensive use, set the interval according to operating conditions.
Do not touch the motor or gate leaf while it is moving; enter only after it is fully open and has stopped. Children must not play near the gate or with the controls. If the gate has a wicket door, opening it must prevent the automation from starting. Regularly remove obstructions and clean the photocell windows. If you hear unusual noise, notice damage or the gate moves by itself, disconnect the power and arrange a repair.
NICE WINGO WG5000 Technical Specifications
| Type | Non-reversible electromechanical drive for one gate leaf, without a built-in control unit. |
|---|---|
| Motor power supply | 230 V AC / 50 Hz |
| Maximum / rated current | 1.5 A / 0.5 A |
| Maximum / rated power input | 200 W / 130 W |
| Stroke | 470 mm |
| No-load speed | 0.013 m/s |
| Maximum / rated force | 1,700 N / 600 N |
| Cycles per hour | 30 at rated force; actual performance depends on installation conditions. |
| Ingress protection rating | IP44 |
| Operating temperature | −20 to +50 °C |
| Insulation class | F |
| Dimensions | 920 × 98 × 95 mm (length × width × height) |
| Motor weight | 6 kg |
| Mechanical stop | Pre-fitted opening stop; closing is controlled by the gate's fixed stop. |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]