NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg
NICE-TO5015
within 3 days
€291.00 excluding VAT
€357.93 including VAT

 pcs
Weight
7,00 kg

Description of NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg

NICE Toona TO5015 is a standalone electromechanical motor for one gate leaf. The motor operates at 230 V AC from a suitable control unit. The motor voltage rating is not the same as the control unit’s mains supply voltage.

Consider the weight and length of one leaf together; the two maximum values listed for the model do not automatically apply at the same time.

The standalone motor requires a suitable 230 V control unit; choose the specific control board and accessories to suit the actual setup.

Quick navigation
AccessoriesLimits
Service lifeInstallation
WiringRelease
SpecificationsMaintenance
Accessories – terminals and polarityPDF manual

  • Non-reversible
  • 230V
  • Slow
  • With a mechanical stop and microswitch; check the end positions against the motor’s actual configuration

Operating range

For the TO5015, the maximum values stated for one leaf are 500 kg and 5 m; these do not automatically apply at the same time. The manufacturer’s manual used here does not separately identify an allowable combination curve for the TO5015. Before choosing a drive, check with the manufacturer or supplier that it is suitable for your leaf’s weight and length.

Service life based on load

Add the indices from all applicable rows, then use the total with the original NICE chart. This is an estimate, not a guarantee of the number of cycles.

Example: a leaf weighing 350 kg and measuring 3.5 m has an index of 10% + 10% = 20%. If another factor from the table applies, add it before using the chart.

Characteristics of the complete automation systemIndexService life chart
Weight up to 300 kg
0%

Original NICE chart: estimated service life based on the total index

Over 300 kg up to 400 kg
10%
Over 400 kg up to 500 kg
20%
Length 2–3 m
0%
Length over 3 m up to 4 m
10%
Length over 4 m up to 5 m
20%
Temperature above 40 °C, below 0 °C, or humidity above 80%
20%
Solid gate leaf infill
15%
Wind exposure
15%

NICE chart


Choosing a control unit

NICE MC800/MCA5R30 is the current control unit and replaces the older A60, A400, A6 and A6F models. The MC200 is also still available for one motor. If an older control unit is already installed, follow the manual for the actual control board.

Currently available

Older compatible control units – discontinued

I. Installing the rear mounting bracket

Post and bracket mounting: For standard mounting, we recommend a sturdy post with a cross-section of 120 × 120 mm. A cross-section of 100 × 100 mm is a guideline minimum, and is suitable only if the post and its foundation are strong enough and the hinge is correctly positioned.

For a different cross-section or hinge offset, adjust the rear bracket or use the extended PLA6 bracket. Dimensions A and B must match the measured C and the opening angle; their meaning is shown in the installation chart. Opening outwards requires an extended rear bracket; determine its length from the installation geometry and check that the gate leaf moves freely.

Diagram of the NICE Toona drive opening inward
Inward-opening diagram

Diagram of the NICE Toona drive opening outward
Outward-opening diagram

Calculate the position of the rear bracket using the chart, which gives you dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) for the drive to move smoothly in a linear motion.

Original NICE installation chart for TO5015
Original NICE installation chart for TO5015

Illustration showing how to calculate the NICE Toona drive installation dimensions
Example of reading values from the chart

Calculation procedure:

  1. Measure the distance C from the drawing
  2. On the installation chart, locate the measured value C and draw a horizontal line from it. Read the corresponding dimension B from the adjacent scale.
  3. Intersection with the r.i.l. line (the recommended installation line on the NICE chart) determines the maximum opening angle; read dimension A vertically from it.
  4. Do not use a dimension B below the dashed line t; NICE does not recommend this area of the chart.
  5. If the opening angle is unsuitable, adjust A and, if necessary, B so that they are approximately equal. Then check the gate leaf's full range of movement again.

Before fixing the bracket to a post or wall, shorten it to the required length corresponding to dimensions A and B and weld it to the mounting plate.

Cut the bracket to the required length
1. Cut the bracket to the required length

Weld the shortened bracket to the mounting plate
2. Weld the shortened bracket to the mounting plate

The supplied rear bracket is 150 mm. Before cutting and welding, check that the bracket will allow you to maintain dimensions A and B from the chart for your post; if you need a longer bracket, follow the recommendation above.

Before fixing the rear bracket, check that the front bracket will sit on the solid part of the gate leaf, since the front and rear brackets differ in height, as shown in the illustration.

According to the NICE drawing, the height difference between the brackets is F = 34 mm. Before welding, check the dimension on the brackets supplied as well.

NICE Toona: F = 34 mm for series 4–5, F = 50 mm for series 6–7

If everything fits, fix the rear bracket to the post or wall using screws, wall plugs and washers.

II. Installing the front mounting bracket

The front bracket must be fitted to the gate leaf at a distance based on the values D and E, which you can read from the table (value D is fixed at 880 mm):

A (mm)E (mm)
100780
110770
120760
130750
140740
150730
160720
170710
180700
190690
200680
210670
220660
230650
240640
250630
260620
270610
280600

The supplied package includes a weld-on bracket. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.

  1. From the table calculate the value of E
  2. Calculate the height according to the illustration bracket heights (view image)
  3. Attach the bracket to the gate leaf (if welding it, we recommend tack-welding it for now)

III. Installing the gate operator on the rear bracket

Installing the NICE Toona operator on the rear bracket

  1. Attach the motor to the bracket as shown, using the supplied rear bracket pin, washer and nut.
  2. Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can rotate

IV. Installing the gate operator on the front bracket

Installing the NICE Toona operator on the front bracket

  1. Attach the operator to the bracket as shown, using the supplied pin and washer.
  2. Tighten the pin fully

V. Limit positions and microswitch

The 230 V motor has a mechanical stop with a microswitch that cuts off power to the motor when it contacts the pin. With the power disconnected, check the actual limit-stop equipment supplied with the operator, set the limit positions, and before operation test the movement and safety devices according to the instructions for the control unit used.

Motor wiring and connections

Disconnect the power supply before wiring. 230 V AC is the motor voltage; the control unit's power supply and accessory outputs must be considered separately. The terminals on the motor are marked AP / COM / CH and protective earth. Carry out the wiring, direction of movement and microswitch checks according to the original NICE diagram and the manual for the control unit used. For outward opening, swap the direction wires as specified by NICE; the protective earth wire remains in place.

Original NICE Toona TO5015 motor terminal diagram

Original NICE diagram for the Toona TO5015 motor

After wiring, check the direction of movement, stop positions and safety devices according to the manual for the specific control unit.

Connecting accessories to the MC800 with an MCA5R30 board

The following wiring applies to MC800/MCA5R30 in kits with this control unit. The accessory terminals belong to the control unit, not the motor itself. For a different control unit, use its own wiring diagram. Disconnect the mains power before starting work.

AccessoriesTerminals, power supply and polarity
Auxiliary power supply
On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common point for the inputs. The total current limit for powered accessories is 200 mA; check each product’s current draw and permitted voltage.
EPM relay photocells
With Standby disabled and photocell testing off, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the volt-free C–NC contact on the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. The AUX inputs must be set to relay photocell mode; in limit-switch mode, they have a different function.
EPM with Standby enabled
According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, max. 4 W and is switched off in Standby; do not use terminal 5 as a permanent negative. Connect the RX C–NC contact between terminal 4 and the relevant PHOTO input.
EPM with photocell testing
Wire according to the photocell test diagram: TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is powered continuously: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the relevant PHOTO input. Do not overload OutSTB or use it to power another load at the same time; after wiring, program the devices and test the safety function.
BlueBUS photocells
Connect compatible EPMB using two wires to BlueBUS terminals 6 and 7. + and − are not polarity-sensitive. Set the address and run device programming whenever a device is added or removed.
STOP and command contacts
The volt-free 12/STOP input accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned during programming. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common).. These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to relays for key switches or external receivers.
ELAC flashing light
Connect the NICE ELAC to the FLASH output for a self-flashing light: switched 120/250 V AC, max. 21 W. This is a mains-voltage output; it has no +/− polarity.. Do not confuse it with the 24 V accessory terminals.
Electric lock
Terminals 1–2 / EL: 12 V AC, max. 15 VA. The AC output has no +/− polarity; check the lock specifications.
Radio receiver
OXIBD is fitted in the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals.

If AUX inputs 8–11 are used for limit switches, they function differently from PHOTO inputs. Whenever you change the photocells or wiring, repeat the relevant programming and test the gate’s stopping and response. For detailed instructions, see the MC800 control unit manual.

MCA5R30 diagram: relay photocells with Standby enabled, BlueBUS and other terminals
Relay photocells in Standby mode

MCA5R30 diagram: power supply and relay photocell contacts during photocell testing
Relay photocells with photocell testing

Accessories by control unit

Choose optional accessories to match the control unit in the specific configuration. Before ordering, check its voltage, inputs, receiver and connection type:

What Why Type
Control unit

The drive’s control electronics.

Warning light Indicates gate movement. The ELAC model has a built-in antenna; when connected correctly, it can improve remote control reception.
  • LED warning light with antenna ELAC

Choose another warning light according to the voltage and load capacity of the actual control unit output.

Photocells

Photocells help detect obstacles; the gate's response depends on the wiring and control unit settings.

For MC800 contact and BlueBUS photocells connect to different inputs. Determine the number of pairs and how they are used based on the actual control board.

  • Wired relay type - EPM
  • Reflector-type relay - EPMOR
  • Vandal-resistant wired relay type - EPMA
  • Wired BlueBUS type - EPMB, EPLB, EPSB
  • BlueBUS reflector type - EPMORB
  • Wireless BlueBUS type - EPMOW
  • Adjustable wired BlueBUS type - F210B
  • Wireless BlueBUS type - FT210B
  • Wired BlueBUS type - EPMOB
Remote control For remote operation of the gate.

Choose the remote control type and coding to match the receiver installed in the control unit being used.

Receiver

For remote operation of the gate.

Before choosing, check the connector and coding supported by the specific control board.

  • BiDi-WiFi – Bus-T4 interface for configuring the automation system; control functions depend on the control board and app used.
  • BiDi-ZWave – interface for the Z-Wave system; check support for the specific control board before choosing.
  • Wired Wi-Fi module, for example Zamel, connect only to a suitable control input on the control unit. SUPLA app: Android / iOS.
  • GSM receivers: GSM modules with a suitable control contact should be connected to the input on the control unit being used.
Antenna

For better remote control range.

  •  built into the warning light ELAC
  • standalone antenna ABFKIT
Keypad Open the gate using a code, without a remote control. For BlueBUS models, check that the actual control unit supports them as control devices.
Key switch Key-operated control via a suitable control input on the control unit; choose the mounting location based on the wiring.
  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder, EKSEU
  • flush-mounted, with a standard cylinder EKSI
  • recessed, with a European cylinder EKSIEU
Card readers Access by card or key fob. ETPB requires a control unit with BlueBUS that supports command devices.
  • ERA Transponder Reader ETPB
Electric locks An electric lock secures the gate leaf in the closed position. Check that the lock is suitable and confirm how it is controlled based on the gate, voltage and output of the control unit being used.

Manual release of the drive

Release or lock the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. In the event of a fault, disconnect the power supply.

  1. Slide back the protective cover, insert the supplied key and turn it clockwise.
  2. Lift the release lever and move the gate leaf by hand.
  3. To lock it again, lower the lever, turn the key counterclockwise, remove it and close the cover.

Original NICE image: manual release of the Toona drive

Before restarting, check that the drive is secured and that nobody is in the gate's path.

Inspection and maintenance

Have the drive inspected by a qualified professional at least every 6 months; more frequent inspections may be needed with intensive use. With the power disconnected, check the fixings, corrosion, wear and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and rectify the cause of the fault.

Technical specifications

ParameterValue
Model
TO5015
Drive motor
230 V AC
Maximum / rated current
1.5 A / 1 A
Maximum / rated power input
340 W / 180 W
Motor capacitor
7 µF
Stroke
540 mm
No-load speed
0.013 m/s
Speed under load
0.010 m/s
Maximum / rated force
1 800 N / 600 N
Cycles per hour at rated force
54
Protection rating
IP44
Operating temperature
−20 to +50 °C
Thermal protection
140 °C
Insulation class
F
Indicative service life according to NICE
80 000 to 250 000 operating cycles
Overall dimensions (length × width × height)
965 × 115 × 105 mm
Motor weight
7 kg

NICE Toona installation manual. Programming, position learning and accessories are covered in the manual for the actual control unit.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg

Product: NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.