NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€357.93 including VAT
| Weight |
|---|
| 7,00 kg |
Description of NICE Toona TO5015 – single-leaf operator for swing gates, for a gate leaf up to 5 m / 500 kg
NICE Toona TO5015 is a standalone electromechanical motor for one gate leaf. The motor operates at 230 V AC from a suitable control unit. The motor voltage rating is not the same as the control unit’s mains supply voltage.
Consider the weight and length of one leaf together; the two maximum values listed for the model do not automatically apply at the same time.
The standalone motor requires a suitable 230 V control unit; choose the specific control board and accessories to suit the actual setup.
| Quick navigation | |
|---|---|
| Accessories | Limits |
| Service life | Installation |
| Wiring | Release |
| Specifications | Maintenance |
| Accessories – terminals and polarity | PDF manual |
- Non-reversible
- 230V
- Slow
- With a mechanical stop and microswitch; check the end positions against the motor’s actual configuration
Operating range
For the TO5015, the maximum values stated for one leaf are 500 kg and 5 m; these do not automatically apply at the same time. The manufacturer’s manual used here does not separately identify an allowable combination curve for the TO5015. Before choosing a drive, check with the manufacturer or supplier that it is suitable for your leaf’s weight and length.
Service life based on load
Add the indices from all applicable rows, then use the total with the original NICE chart. This is an estimate, not a guarantee of the number of cycles.
Example: a leaf weighing 350 kg and measuring 3.5 m has an index of 10% + 10% = 20%. If another factor from the table applies, add it before using the chart.
| Characteristics of the complete automation system | Index | Service life chart |
|---|---|---|
Weight up to 300 kg | 0% | |
Over 300 kg up to 400 kg | 10% | |
Over 400 kg up to 500 kg | 20% | |
Length 2–3 m | 0% | |
Length over 3 m up to 4 m | 10% | |
Length over 4 m up to 5 m | 20% | |
Temperature above 40 °C, below 0 °C, or humidity above 80% | 20% | |
Solid gate leaf infill | 15% | |
Wind exposure | 15% |
| NICE chart |
|---|
Choosing a control unit
NICE MC800/MCA5R30 is the current control unit and replaces the older A60, A400, A6 and A6F models. The MC200 is also still available for one motor. If an older control unit is already installed, follow the manual for the actual control board.
Currently available
- NICE MC800 – for one or two 230 V motors.
- NICE MC200 – for one 230 V motor.
Older compatible control units – discontinued
I. Installing the rear mounting bracket
Post and bracket mounting: For standard mounting, we recommend a sturdy post with a cross-section of 120 × 120 mm. A cross-section of 100 × 100 mm is a guideline minimum, and is suitable only if the post and its foundation are strong enough and the hinge is correctly positioned.
For a different cross-section or hinge offset, adjust the rear bracket or use the extended PLA6 bracket. Dimensions A and B must match the measured C and the opening angle; their meaning is shown in the installation chart. Opening outwards requires an extended rear bracket; determine its length from the installation geometry and check that the gate leaf moves freely.
Calculate the position of the rear bracket using the chart, which gives you dimensions A and B and the maximum opening angle. Note that values A and B must be similar (ideally identical) for the drive to move smoothly in a linear motion.

Original NICE installation chart for TO5015

Example of reading values from the chart
Calculation procedure:
- Measure the distance C from the drawing
- On the installation chart, locate the measured value C and draw a horizontal line from it. Read the corresponding dimension B from the adjacent scale.
- Intersection with the r.i.l. line (the recommended installation line on the NICE chart) determines the maximum opening angle; read dimension A vertically from it.
- Do not use a dimension B below the dashed line t; NICE does not recommend this area of the chart.
- If the opening angle is unsuitable, adjust A and, if necessary, B so that they are approximately equal. Then check the gate leaf's full range of movement again.
Before fixing the bracket to a post or wall, shorten it to the required length corresponding to dimensions A and B and weld it to the mounting plate.

1. Cut the bracket to the required length

2. Weld the shortened bracket to the mounting plate
The supplied rear bracket is 150 mm. Before cutting and welding, check that the bracket will allow you to maintain dimensions A and B from the chart for your post; if you need a longer bracket, follow the recommendation above.
Before fixing the rear bracket, check that the front bracket will sit on the solid part of the gate leaf, since the front and rear brackets differ in height, as shown in the illustration.
According to the NICE drawing, the height difference between the brackets is F = 34 mm. Before welding, check the dimension on the brackets supplied as well.
If everything fits, fix the rear bracket to the post or wall using screws, wall plugs and washers.
II. Installing the front mounting bracket
The front bracket must be fitted to the gate leaf at a distance based on the values D and E, which you can read from the table (value D is fixed at 880 mm):
| A (mm) | E (mm) |
|---|---|
| 100 | 780 |
| 110 | 770 |
| 120 | 760 |
| 130 | 750 |
| 140 | 740 |
| 150 | 730 |
| 160 | 720 |
| 170 | 710 |
| 180 | 700 |
| 190 | 690 |
| 200 | 680 |
| 210 | 670 |
| 220 | 660 |
| 230 | 650 |
| 240 | 640 |
| 250 | 630 |
| 260 | 620 |
| 270 | 610 |
| 280 | 600 |
The supplied package includes a weld-on bracket. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.
- From the table calculate the value of E
- Calculate the height according to the illustration bracket heights (view image)
- Attach the bracket to the gate leaf (if welding it, we recommend tack-welding it for now)
III. Installing the gate operator on the rear bracket
- Attach the motor to the bracket as shown, using the supplied rear bracket pin, washer and nut.
- Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can rotate
IV. Installing the gate operator on the front bracket
- Attach the operator to the bracket as shown, using the supplied pin and washer.
- Tighten the pin fully
V. Limit positions and microswitch
The 230 V motor has a mechanical stop with a microswitch that cuts off power to the motor when it contacts the pin. With the power disconnected, check the actual limit-stop equipment supplied with the operator, set the limit positions, and before operation test the movement and safety devices according to the instructions for the control unit used.
Motor wiring and connections
Disconnect the power supply before wiring. 230 V AC is the motor voltage; the control unit's power supply and accessory outputs must be considered separately. The terminals on the motor are marked AP / COM / CH and protective earth. Carry out the wiring, direction of movement and microswitch checks according to the original NICE diagram and the manual for the control unit used. For outward opening, swap the direction wires as specified by NICE; the protective earth wire remains in place.
After wiring, check the direction of movement, stop positions and safety devices according to the manual for the specific control unit.
Connecting accessories to the MC800 with an MCA5R30 board
The following wiring applies to MC800/MCA5R30 in kits with this control unit. The accessory terminals belong to the control unit, not the motor itself. For a different control unit, use its own wiring diagram. Disconnect the mains power before starting work.
| Accessories | Terminals, power supply and polarity |
|---|---|
Auxiliary power supply | On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common point for the inputs. The total current limit for powered accessories is 200 mA; check each product’s current draw and permitted voltage. |
EPM relay photocells | With Standby disabled and photocell testing off, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the volt-free C–NC contact on the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. The AUX inputs must be set to relay photocell mode; in limit-switch mode, they have a different function. |
EPM with Standby enabled | According to the MCA5R30 diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, max. 4 W and is switched off in Standby; do not use terminal 5 as a permanent negative. Connect the RX C–NC contact between terminal 4 and the relevant PHOTO input. |
EPM with photocell testing | Wire according to the photocell test diagram: TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is powered continuously: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the relevant PHOTO input. Do not overload OutSTB or use it to power another load at the same time; after wiring, program the devices and test the safety function. |
BlueBUS photocells | Connect compatible EPMB using two wires to BlueBUS terminals 6 and 7. + and − are not polarity-sensitive. Set the address and run device programming whenever a device is added or removed. |
STOP and command contacts | The volt-free 12/STOP input accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned during programming. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common).. These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to relays for key switches or external receivers. |
ELAC flashing light | Connect the NICE ELAC to the FLASH output for a self-flashing light: switched 120/250 V AC, max. 21 W. This is a mains-voltage output; it has no +/− polarity.. Do not confuse it with the 24 V accessory terminals. |
Electric lock | Terminals 1–2 / EL: 12 V AC, max. 15 VA. The AC output has no +/− polarity; check the lock specifications. |
Radio receiver | OXIBD is fitted in the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna according to the receiver instructions, not to the motor terminals. |
If AUX inputs 8–11 are used for limit switches, they function differently from PHOTO inputs. Whenever you change the photocells or wiring, repeat the relevant programming and test the gate’s stopping and response. For detailed instructions, see the MC800 control unit manual.

Relay photocells in Standby mode

Relay photocells with photocell testing
Accessories by control unit
Choose optional accessories to match the control unit in the specific configuration. Before ordering, check its voltage, inputs, receiver and connection type:
| What | Why | Type |
|---|---|---|
| Control unit |
The drive’s control electronics. |
|
| Warning light | Indicates gate movement. The ELAC model has a built-in antenna; when connected correctly, it can improve remote control reception. |
Choose another warning light according to the voltage and load capacity of the actual control unit output. |
| Photocells |
Photocells help detect obstacles; the gate's response depends on the wiring and control unit settings. For MC800 contact and BlueBUS photocells connect to different inputs. Determine the number of pairs and how they are used based on the actual control board. |
|
| Remote control | For remote operation of the gate. Choose the remote control type and coding to match the receiver installed in the control unit being used. |
|
| Receiver |
For remote operation of the gate. Before choosing, check the connector and coding supported by the specific control board. |
|
| Antenna |
For better remote control range. |
|
| Keypad | Open the gate using a code, without a remote control. For BlueBUS models, check that the actual control unit supports them as control devices. | |
| Key switch | Key-operated control via a suitable control input on the control unit; choose the mounting location based on the wiring. | |
| Card readers | Access by card or key fob. ETPB requires a control unit with BlueBUS that supports command devices. |
|
| Electric locks | An electric lock secures the gate leaf in the closed position. Check that the lock is suitable and confirm how it is controlled based on the gate, voltage and output of the control unit being used. |
|
Manual release of the drive
Release or lock the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. In the event of a fault, disconnect the power supply.
- Slide back the protective cover, insert the supplied key and turn it clockwise.
- Lift the release lever and move the gate leaf by hand.
- To lock it again, lower the lever, turn the key counterclockwise, remove it and close the cover.
Before restarting, check that the drive is secured and that nobody is in the gate's path.
Inspection and maintenance
Have the drive inspected by a qualified professional at least every 6 months; more frequent inspections may be needed with intensive use. With the power disconnected, check the fixings, corrosion, wear and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and rectify the cause of the fault.
Technical specifications
| Parameter | Value |
|---|---|
Model | TO5015 |
Drive motor | 230 V AC |
Maximum / rated current | 1.5 A / 1 A |
Maximum / rated power input | 340 W / 180 W |
Motor capacitor | 7 µF |
Stroke | 540 mm |
No-load speed | 0.013 m/s |
Speed under load | 0.010 m/s |
Maximum / rated force | 1 800 N / 600 N |
Cycles per hour at rated force | 54 |
Protection rating | IP44 |
Operating temperature | −20 to +50 °C |
Thermal protection | 140 °C |
Insulation class | F |
Indicative service life according to NICE | 80 000 to 250 000 operating cycles |
Overall dimensions (length × width × height) | 965 × 115 × 105 mm |
Motor weight | 7 kg |
NICE Toona installation manual. Programming, position learning and accessories are covered in the manual for the actual control unit.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]








