NICE Toona TO5024 – standalone operator for swing gates with a leaf up to 5 m/500 kg
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€362.06 including VAT
| Weight |
|---|
| 9,00 kg |
Description of NICE Toona TO5024 – standalone operator for swing gates with a leaf up to 5 m/500 kg
NICE Toona TO5024 is a standalone motor 24 V DC for one gate leaf swing gate. It is non-reversible, has an aluminium housing and a bronze lead nut. The 24 V rating refers to the motor, not necessarily to the control unit's mains supply.
Operating limits: 5 m and 500 kg are not permitted at the same time. At 5 m, the graph allows approximately 200 kg; 500 kg is allowed up to approximately 1.8 m. Check the specific combination against the TO5024 curve; allow for higher loads with solid infill and in windy conditions. When replacing an older operator, check the dimensions of the brackets and pins.
The motor's magnetic encoder works with a compatible control unit. Current MC824HR30/MCA1R30 supports position learning, BlueBUS and settings as described in its own manual. The older MC824HR10 has a different circuit board. Choose the kit contents, photocells, radio receiver and battery based on the actual control unit.
| Quick navigation | |
|---|---|
| What's in the box | Kits |
| Accessories | Limits |
| Service life | Installation |
| Wiring | Stop |
| Manual release | Specifications |
| Manual | Photo gallery |
| Accessories – terminals and polarity | PDF manual |
| The operator includes: | Code | |||
|---|---|---|---|---|
![]() |
1 × | NICE Toona 5 TO5024 motor |
TO5024 |
|
|
TO5024 motor: a gate leaf length of up to 5 m and a weight of up to 500 kg are separate maximum values. Determine the permitted combination from the chart below. |
||||
![]() |
1 × | Internal mechanical opening stop | PLA13 | |
|
The internal stop limits how far the gate leaf opens. Determine whether external stops are needed and how the closed position is secured based on the complete gate and the selected control unit. Stop adjustment. |
||||
![]() |
2 × | Release key | CM-B | |
|
In the event of a power failure, it releases the operator so the gate can be moved manually by pushing or pulling. |
||||
![]() |
1 × | Front weld-on bracket |
PMD0101R04.4610 |
|
|
Weld it to the fixed part of the gate leaf. Note that it is installed at a different height from the rear bracket. The alternative bolt-on bracket is the PLA8. |
||||
![]() |
1 × | Front bracket pin | R8.5120 Washer V8X10.5102 Pin |
|
|
Used to attach the front end of the operator to the front bracket. |
||||
![]() |
1 × | Rear weld-on bracket | PMDSMP.4610 | |
|
Weld it to the mounting screw plate or a steel post. Note that it is installed at a different height from the front bracket. The alternative extended bracket is the PLA6. |
||||
![]() |
1 × | Mounting plate for the rear bracket | PMDPA.4610 | |
|
The rear bracket is welded to it. The mounting plate is then fastened to a post or wall. |
||||
![]() |
2 × | Rear bracket pin | D10.5110 Nut R10.5120 Washer V10X40.5101 Pin |
|
|
Used to attach the rear of the drive to the rear bracket. |
||||
![]() |
1 × | NICE Toona 5 TO5024 installation manual | Download | |
|
The motor installation manual includes dimensions, mounting instructions, wiring and safety checks. Program and pair the remote controls according to the instructions for the control unit and receiver actually installed. |
||||
A standalone motor requires a control unit and, depending on the gate, safety accessories. Package contents, limits chart and technical specifications can be found below.
(Is this drive right for me?)
Compare it with other drives:
BlueBUS is the interface for the selected control unit and accessories. Check the specific product for the availability of alternative models.
Discounted sets containing drive NICE Toona 5 TO5024:
| Single-leaf gate kit » | Double-leaf gate kit » |
|---|---|
|
Toona drive with length and weight limits as shown in the chart, control unit, remote control and receiver. |
2 x Toona drives with length and weight limits as shown in the chart, control unit, remote control and receiver. |
| Single-leaf gate kit with photocells » | Double-leaf gate kit with photocells » |
|
Toona drive with length and weight limits as shown in the chart, control unit, remote control, receiver and photocells. |
2 x Toona drives with length and weight limits as shown in the chart, control unit, remote control, receiver and photocells. |
| Single-leaf gate kit with accessories » | Double-leaf gate kit with accessories » |
|
Toona drive with length and weight limits as shown in the chart, control unit, remote control, receiver, photocells and warning light. |
2 x Toona drives with length and weight limits as shown in the chart, control unit, remote control, receiver, photocells and warning light. |
Accessories compatible with the NICE Toona 5 TO5024 drive
Choose optional accessories according to the control unit in the specific setup. Check its connectors, outputs, BlueBUS and receiver coding:
| What | Why | Type |
|---|---|---|
| Control unit | Electronics for the motor; choose the manual for the control board actually installed. |
|
| Warning light | Signals movement. Only models specified by the manufacturer include an antenna. The choice depends on the control unit output. |
On the MC824HR30, the FLASH output is intended for a 12 V warning light up to 21 W. For other lights, check the voltage, power rating and flashing mode. |
| Photocells | They monitor the beam area and send a signal to the control unit. The gate's response depends on the wiring and settings; test the complete setup after installation. | |
| Transmitter | Choose the remote control to match the receiver and coding installed in the control unit. ON3EBD is compatible with OXIBD; ON3ELR with OXILR. | |
| Receiver | The radio receiver must support the remote control's coding; smart home interfaces have different functions. |
|
| Antenna | Improves receiver reception when correctly positioned and connected. | |
| Keypad | Code access. A BlueBUS keypad requires a control board that supports command devices. | |
| Key switch | Control via a suitable control input on the control unit. | |
| Electric locks | Secures the gate leaf; check the lock's control method and voltage against the control unit and installation. |
|
| Card readers | ETPB requires the specific control board to support BlueBUS command devices. |
|
| Backup power supply | A battery connected to a compatible control unit enables operation during a mains power failure. |
NICE Toona 5 TO5024 operator manual
TO5024 motor installation: original NICE manual. Programming: follow the manual for the installed control unit – for the current model, MC824HR30/MCA1R30 the R30 manual; for the older MC824HR10/MCA1R10, its Slovak manual.
Choosing an operator – is the operator NICE Toona 5 TO5024 suitable for my gate?
TO5024 limits: The maximum values of 5 m and 500 kg cannot be used at the same time. At 5 m, the curve allows approximately 200 kg; 500 kg is allowed up to approximately 1.8 m. For your gate, read the permitted combination from the curve explicitly labelled TO5024.
Service life according to load
Add the relevant indices for one leaf and read the estimate from the NICE chart. Manufacturer’s example: 350 kg and 3.5 m = 10% + 10% = 20%; with no other factors, approximately 160,000 cycles. This is an estimate, not a guarantee.
| Characteristics of the complete automation system | Index | Service life chart |
|---|---|---|
Weight up to 300 kg | 0% | |
Over 300 kg up to 400 kg | 10% | |
Over 400 kg up to 500 kg | 20% | |
Length 2–3 m | 0% | |
Length over 3 m up to 4 m | 10% | |
Length over 4 m up to 5 m | 20% | |
Temperature above 40°C, below 0°C, or humidity above 80% | 20% | |
Solid gate leaf infill | 15% | |
Wind exposure zone | 15% |
| NICE chart |
|---|
Installing the NICE Toona 5 TO5024 operator
A typical (optional) operator wiring setup with accessories looks as follows:
List of accessories
|
NICE Toona TO5024 operator wiring
The TO5024 motor is 24 V DC and has separate encoder wires. Disconnect the power before wiring; the terminals on the motor correspond to the original NICE diagram. Connect to the control unit, set the motor sequence, and program the positions according to the specific installed control board.
| 1. Remove the operator cover | 2. Feed through the power cable |
|---|---|
![]() |
![]() |
| 3. Connect the operator power supply | 4. Operator power supply wiring diagram |
|
For outward opening, NICE specifies reversing the motor power polarity compared with a standard installation. An extended rear bracket PLA6 and the correct geometry according to the installation chart are also required. Check the direction, terminals, and encoder against the actual control unit. |
On the other side, connect the wiring to the control unit as follows: Check the wiring on the current MC824HR30 against the control board manual |
Accessory wiring for the MC824HR30
The following terminals belong to the MC824HR30/MCA1R30 control unit in an assembly with a TO5024 motor, not to the motor itself. Disconnect the mains power and backup battery before working. For a different control board, use its own wiring diagram.
| Accessories | Terminals, voltage, and polarity |
|---|---|
| BlueBUS photocells | Connect compatible photocells, such as EPMB, using a two-wire connection to BlueBUS. + and − are not polarity-sensitive. Set the address and repeat the learning procedure after changing devices. |
| STOP and control inputs | Input STOP accepts a voltage-free NO or NC contact, or an 8.2 kΩ resistor ; its state is learned.; its state is learned. SbS, Open, and Close accept a voltage-free NO contact on the corresponding pair of terminals. Contacts have no +/− polarity; do not apply an external voltage to the input. |
| Auxiliary power supply | Right terminal of the STOP pair = −; left terminal of the SbS pair = +, when viewed in the orientation shown below (labels above the terminals). Power supply for a suitable reader or module: 24 V DC (−30% to +50%), max. 200 mA, including in Stand-by mode. Wire the module’s command relay separately as a voltage-free contact; check the permitted voltage range and current draw of the module. |
| Warning light, lock, indicator light | FLASH: 12 V DC, max. 21 W; ELS: 12 V AC, max. 15 VA, no fixed +/− polarity; OGI: 24 V DC, max. 4 W. For FLASH/OGI, the diagram does not specify the +/− order on the pair of terminals, so do not guess; for a polarized product, check the markings on both the control board and the product. The outputs may have different functions depending on the programming. |
| Radio and backup | The plug-in receiver goes into the SM, and the backup battery into its connector, depending on the installed board. They are not connected to BlueBUS or to the motor terminals. |
For detailed terminal positions, programming and testing of the safety devices, see the MC824HR30 control unit manual.
I. Installing the rear mounting bracket
Bracket mounting: Before installation, measure the hinge offset and dimensions A/B/C according to the installation diagram. For a standard steel post, we recommend 120 × 120 mm. Profile 100 × 100 mm use only after assessing the strength of the post, anchoring and foundation for the gate and wind loads.
If the diagram dimensions do not work, adjust the rear bracket or use the extended PLA6. When opening outward, an extended rear bracket is required; determine its position from the diagram and check that the gate leaf moves freely.
![]() |
![]() |
| Diagram of inward opening | Diagram of outward opening |
Calculate the rear bracket position using the diagram, which shows the dimensions A and B and maximum opening angle. Note that the values A and B must be similar (ideally identical) to ensure the operator moves smoothly in a straight line.
The example explains how to read the values. Determine the dimensions for TO5024 using the model installation diagram immediately below.
Calculation procedure:
- Measure the distance C in the diagram
- Find the measured C value on the diagram, draw a horizontal line, and read B from the adjacent scale.
- The intersection with the d.i.l. line indicates the maximum opening angle; read A from it by drawing a vertical line.
- The manufacturer does not recommend B values below the dashed line t.
- If the angle is unsuitable, adjust A and, if necessary, B so they are approximately equal; check the gate leaf throughout its full travel.
Before attaching the bracket to a post or wall, cut it to the required length corresponding to dimensions A and B and weld it to the mounting plate.
![]() |
![]() |
| 1. Cut the bracket to the required length | 2. Weld the shortened bracket to the mounting plate |
The supplied rear bracket is 150 mm. Before cutting and welding, check that the resulting dimensions match the diagram.
If everything is suitable, attach the rear bracket to the post or wall using screws, wall plugs and washers.
II. Installing the front mounting bracket
The front bracket must be fitted to the gate leaf at a distance determined by the values D and E, which you can read from the table (the value D is fixed at 880 mm):
| A (mm) | E (mm) |
|---|---|
| 100 | 780 |
| 110 | 770 |
| 120 | 760 |
| 130 | 750 |
| 140 | 740 |
| 150 | 730 |
| 160 | 720 |
| 170 | 710 |
| 180 | 700 |
| 190 | 690 |
| 200 | 680 |
| 210 | 670 |
| 220 | 660 |
| 230 | 650 |
| 240 | 640 |
| 250 | 630 |
| 260 | 620 |
| 270 | 610 |
| 280 | 600 |
The supplied package includes a weld-on bracket. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.
- Calculate from the table the value E
- Calculate the height according to the diagram bracket heights (view image)
- Attach the bracket to the gate leaf (if welding the bracket, we recommend tack-welding it for now only)
III. Installing the gate operator on the rear bracket
IV. Installing the gate operator on the front bracket
![]() |
|
V. Adjusting the mechanical travel stop
The TO5024 has an internal mechanical opening stop. First release the motor, loosen the stop screw, set the desired open position manually, slide the stop up against the pin, and tighten the screw. Then move the gate leaf back to the closed position manually and lock the motor. Set the closed position and any external stop according to the specific gate and control unit.
![]() |
|
NICE Toona operator photo gallery
|
Installation example |
Installation example |
Installation example |
|
Installation example |
Installation example |
Operator with cover removed |
|
Comparison of Toona 4, 5 and 7 operators |
Operator in released mode |
Underside view |
Manual release of NICE Toona 5 TO5024 operator
Release the operator only when the gate leaf is stationary. If the gate has an electric lock, unlock it first; after moving the gate manually, secure the operator again.
In the event of a power failure, you will not be able to operate the gate using the remote control. Therefore, the operator can be released using the release key and the gate can be moved manually:
- Slide the release lock cover aside
- Insert the release key and turn it clockwise
- Pull out the release lever and you can move the gate manually
Inspection and maintenance
Have the operator professionally inspected at least every 6 months; more frequent inspections may be necessary with intensive use. With the power disconnected, check the mounting, corrosion, wear and lubrication of the lead screw and guide nut, then test the movement and safety devices. If the gate behaves unusually, stop automatic operation and identify and fix the cause of the fault.
Technical specifications of the NICE Toona 5 TO5024 operator
| Parameter | Value |
|---|---|
Model | TO5024 |
Drive motor | 24 V DC |
Maximum / rated current | 5 A / 2,2 A |
Maximum / rated power consumption | 120 W / 48 W |
Stroke | 540 mm |
No-load speed | 0,016 m/s |
Speed under load | 0,012 m/s |
Maximum / rated force | 1 800 N / 600 N |
Cycles per hour at rated force | 95 |
Protection rating | IP44 |
Operating temperature | −20 to +50 °C |
Insulation class | F |
Estimated service life according to NICE | 80 000 to 250 000 operating cycles |
Overall dimensions (length × width × height) | 965 × 115 × 105 mm |
Motor weight | 7 kg |