NICE Toona TO7024 – 24 V swing gate operator for gates up to 7 m
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€588.49 including VAT
| Weight |
|---|
| 12 kg |
Description of NICE Toona TO7024 – 24 V swing gate operator for gates up to 7 m
NICE Toona TO7024 is a standalone electromechanical actuator 24 V DC with a magnetic encoder for one gate leaf. Weight up to 1 700 kg and length up to 7 m are maximum values; the permissible combination is determined by the TO7024 curve. The actuator is non-reversible and has a robust aluminium housing.
The motor has separate internal opening and closing stops. 24 V indicates the voltage of the motor; mains power supply and accessory functions depend on the control unit actually installed. The current MC824HR30/MCA1R30 has its own manual. For the older MC824HR10/MCA1R10, follow the procedure for its board.
What the standalone actuator includes
| The actuator includes: | Code | |||
|---|---|---|---|---|
![]() |
1 × | NICE Toona 7 TO7024 actuator |
TO7024 |
|
|
NICE Toona TO7024 electromechanical actuator. The values of up to 1 700 kg and up to 7 m are maximum limits; check the graph for the permissible combination. |
||||
![]() |
2 × | Internal opening and closing stops | PMD1641R01.4610 | |
|
The internal stops set the open and closed positions; assess whether additional stops are needed based on the gate as a whole. Adjustment instructions. |
||||
![]() |
2 × | Release key | CM-B | |
|
In the event of a power failure, it releases the actuator so the gate can be moved manually by pushing or pulling it. |
||||
![]() |
1 × | Screw-on front bracket |
PMD1640R02.4610 |
|
|
It is screwed to the fixed part of the gate leaf. Note that it is positioned at a different height than the rear bracket. |
||||
![]() |
1 × | Front bracket pin | R8.5120 Washer V8X16.5102 Pin |
|
|
Used to attach the front of the actuator to the front bracket. |
||||
![]() |
1 × | Weld-on rear bracket | PMD1642.4610 | |
|
It is welded to a screw-on mounting plate or a steel post. Note that it is positioned at a different height than the front bracket. |
||||
![]() |
1 × | Mounting plate for the rear bracket | PMD1639.4610 | |
|
The rear bracket is welded to it. The mounting plate is then fastened to a post or wall. |
||||
![]() |
2 × | Rear bracket pin | D12.5110 Nut R12.5120 Washer V12X60.5102 Pin |
|
|
Used to secure the rear of the drive to the rear bracket. |
||||
This product page is for the motor only, supplied with mounting parts. Automatic operation requires a suitable control unit and safety devices for the entire gate; the contents of ready-made kits are listed on their individual product pages.
Discounted kits with TO7024
Check the contents and number of motors in each kit. Gate leaf suitability is determined by TO7024 curve; 7 m and 1,700 kg are not simultaneous values.
| Single-leaf gate kit » | Double-leaf gate kit » |
|---|---|
|
TO7024 drive, control unit, remote control, receiver. |
2 x TO7024 drives, control unit, remote control, receiver. |
| Single-leaf gate kit with photocells » | Double-leaf gate kit with photocells » |
|
TO7024 drive, control unit, remote control, receiver, photocells. |
2 x TO7024 drives, control unit, remote control, receiver, photocells. |
| Single-leaf gate kit with accessories » | Double-leaf gate kit with accessories » |
|
TO7024 drive, control unit, remote control, receiver, photocells, warning light. |
2 x TO7024 drives, control unit, remote control, receiver, photocells, warning light. |
Connecting accessories to the MC824HR30
The following terminals belong to the MC824HR30/MCA1R30 control unit when used with the TO7024 motor, not to the motor itself. Disconnect the mains supply and backup battery before working. For a different board, use its own wiring diagram.
| Accessories | Terminals, voltage and polarity |
|---|---|
| BlueBUS photocells | Connect compatible photocells, such as EPMB, using a two-wire connection to BlueBUS. + and − are not polarity-sensitive. Set the address and repeat the learning procedure after changing devices. |
| STOP and command inputs | The STOP input accepts a volt-free NO or NC contact, or a device with an 8.2 kΩresistor; its state is learned. SbS, Open and Close accept a volt-free NO contact on the corresponding pair of terminals. Contacts have no +/− polarity; do not apply an external voltage to the input. |
| Auxiliary power supply | Right terminal of the STOP pair = −; left terminal of the SbS pair = +, when viewed in the orientation shown below (labels above the terminals). Power supply for a suitable reader or module: 24 V DC (−30% to +50%), max. 200 mA, including in Stand-by mode. Wire the module's command relay separately as a volt-free contact; check the permitted voltage range and current draw of the module. |
| Warning light, lock, indicator light | FLASH: 12 V DC, max. 21 W; ELS: 12 V AC, max. 15 VA, no fixed +/− polarity; OGI: 24 V DC, max. 4 W. For FLASH/OGI, the diagram does not specify the +/− order on the pair of terminals, so do not assume it; for a polarised product, check the markings on both the board and the product. Outputs may have a different function depending on the programming. |
| Radio receiver and backup power | The plug-in receiver goes into the SM, and the backup battery into its designated connector, depending on the board installed. They do not connect to BlueBUS or to the motor terminals. |
For detailed terminal locations, the learning procedure and safety device testing, see the in the MC824HR30 control unit's own manual.
Accessories by control unit
The choice depends on the actual board, inputs, receiver and voltage. An older compatible board does not thereby become a current-generation model.
| What | Why | Type |
|---|---|---|
| Control unit | Motor electronics; choose the manual for the board actually installed. |
|
| Flashing beacon | Signals movement. Only models for which the manufacturer specifies an antenna include one. The choice depends on the control unit's output. |
For the MC824HR30, the FLASH output is intended for a 12 V beacon up to 21 W. For other lights, check the voltage, power consumption and flashing mode. |
| Photocells | They monitor the beam area and send a signal to the control unit. The gate's response depends on the wiring and settings; test the complete system after installation. | |
| Transmitter | Choose a remote control to match the receiver and coding installed in the control unit. ON3EBD is compatible with OXIBD; ON3ELR is compatible with OXILR. | |
| Receiver | The radio receiver must support the remote control's coding; smart home interfaces offer different functions. |
|
| Antenna | Improves receiver reception when correctly positioned and connected. | |
| Keypad | Code-operated control. A BlueBUS keypad requires a control board that supports command devices. | |
| Key switch | Control via a suitable input on the control unit. | |
| Electric locks | Secures the gate leaf; check the lock’s control method and voltage against the control unit and installation. |
|
| Card readers | ETPB requires the specific control board to support BlueBUS command devices. |
|
| Backup power supply | A battery connected to a compatible control unit enables operation during a power outage. |
Operating range for a single gate leaf
Length and weight are shared limits. Curve TO7024 supports 1,700 kg at 3 m; at 7 m, approximately 750 kg. Use only the curve for your model and take account of movement resistance, solid infill and wind; the maximum figures cannot automatically be combined.
Service life based on load
For a single gate leaf, add the relevant weight, length and environmental indices. Then compare the total with the NICE graph. The graph does not show values above 100%. This is an approximate service life estimate of 80,000 to 250,000 operating cycles depending on load, not a guarantee.
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Weight up to 400 kg | 0% | |
| Over 400 up to 500 kg | 10% | |
| Over 500 kg | 20% | |
| Length 2–3 m | 0% | |
| Length 3–4 m | 0% | |
| Length over 4 up to 5 m | 10% | |
| Length over 5 up to 6 m | 20% | |
| Length over 6 up to 7 m | 30% | |
| Temperature above 40 °C, below 0 °C or humidity above 80% | 20% | |
| Solid gate-leaf infill | 15% | |
| Windy area | 15% |
| NICE graph |
|---|
Installing the operator and brackets
Before installation, check that the gate is sturdy, the leaf moves smoothly by hand, there is space to release the operator, and a suitable mounting point is available on a rigid part of the leaf.
Rear bracket mounting and graph A/B/C
Post and brackets: As a general guide, we recommend a sturdy steel post measuring 120 × 120 mm. For 100 × 100 mm assess the wall thickness, anchoring, foundation, hinge offset and wind load separately. The cross-section alone does not guarantee strength.
Measure the hinge offset C. On the original TO7024 graph, draw a horizontal line from C and read off B; the intersection with the recommended r.i.l. line determines the angle and the vertical line gives A. Dimensions A and B should be similar. NICE does not recommend B values below line t.
If the post profile or hinge position makes it impossible to follow the graph, the rear bracket must be modified or a suitable extended mounting bracket for Toona 6–7. An extended rear bracket is required when the gate opens outwards. Choose the dimensions to suit the actual gate and check the full movement before making the final weld.
Once the geometry has been checked, securely connect the rear bracket to the mounting plate and post. Choose fasteners for the post according to the substrate. Secure the front bracket to a rigid part of the gate leaf; the operator must have a small amount of play at the pins to prevent it from binding.
A separate PMD1642.4610 rear bracket. This is a replacement part for the original mounting bracket; any extension required for non-standard geometry must be designed separately.
Dimension D = 1 070 mm. After determining A from the graph, read E from the NICE table; the height difference between the front and rear brackets is F = 50 mm.
| A (mm) | E (mm) |
|---|---|
| 180 | 890 |
| 190 | 880 |
| 200 | 870 |
| 210 | 860 |
| 220 | 850 |
| 230 | 840 |
| 240 | 830 |
| 250 | 820 |
| 260 | 810 |
| 270 | 800 |
| 280 | 790 |
For the rear pin, NICE specifies tightening the nut and then loosening it by 1/10 turn, so that minimal clearance remains between the parts. Tighten the front fixing as shown in the manufacturer's drawing.
Motor cabling and wiring
Before opening the cover and making connections, disconnect the power supply. The drive has separate terminals for the encoder and 24 V DC motor; do not mix them up. Connect the wires and protective earth according to the original NICE diagram and the instructions for the control unit actually installed. The 24 V marking indicates the motor voltage, not necessarily the control unit's mains power supply.
When opening outwards, the motor power polarity is reversed according to NICE. The mounting geometrymust also be designed correctly; changing the wires alone is not sufficient. Then check the direction of movement, stop positions and safety devices according to the instructions for the control board installed.
Internal opening and closing stops
On the Toona 6–7 series, the mechanical stops are adjusted for both opening and closing. Unlock the motor and move the gate leaf so that the stop screw is accessible. Loosen it, manually set the required open position, slide the stop up to the pin and tighten it. Repeat the same procedure at the required closed position, then lock the motor. Check the final positions and the safety of the entire gate during testing.
Test before first use
After installation and stop adjustment, test the entire gate, not just the motor starting. With the drive unlocked, NICE specifies checking the manual movement of the gate leaf using a force of no more than 390 N.
- Check that the gate moves smoothly by hand throughout its full travel, that the brackets are secure, and that it can be unlocked safely.
- Repeatedly issue open, stop and close commands; check the direction, run-on, stops and, for a double-leaf gate, the sequence according to the control unit instructions.
- Check each photocell, safety edge and other installed protective device individually. Measure the operating forces in accordance with applicable requirements; the gate may be used only after it passes the test.
Practical TO7024 installation examples

Shortening the rear bracket after determining the installation dimensions

Welding the rear bracket to the mounting plate

Attaching the drive to the rear bracket

Attaching the TO7024 to the front bracket

Removing the drive cover before routing the cable

Routing the cable into the drive

Example of adjusting the TO7024 internal stops
Manual release of the drive
Unlock or lock the drive only when the gate leaf is stationary. If an electric lock is installed, unlock it first. In the event of a fault, disconnect the power supply.
- Slide the release lock cover aside.
- Insert the supplied key and turn it clockwise.
- Lift the lever and move the gate leaf by hand. To relock, lower the lever, turn the key back, remove it and close the cover.
Inspection and maintenance
Service at least every 6 months. After disconnecting the power supply, check the fixings, corrosion, wear, bolted joints and lubrication of the screw and nut. After switching on the power, test the movement, release mechanism and all safety devices.
Installation photos of the NICE Toona range
The photos show different Toona configurations. For the TO7024, the model drawings above provide the installation dimensions and wiring details; the terminal block photo is for reference only.

NICE Toona drive on a slatted swing gate

NICE Toona drive mounted on a steel post

Swing gate with a Toona drive and a separate control box

NICE Toona drive on a green swing gate

Double-leaf gate with two NICE Toona operators

Illustrative photo of the terminal block of a Toona 24 V operator

Length comparison of NICE Toona series operators

Manually released NICE Toona operator

View of the underside of a NICE Toona operator
Technical specifications
| Parameter | Value |
|---|---|
| Model | TO7024 |
| Motor voltage | 24 V DC |
| Maximum / rated current draw | 5 A / 2.5 A |
| Maximum / rated power consumption | 120 W / 60 W |
| Stroke | 584 mm |
| No-load speed | 0,013 m/s |
| Maximum / rated force | 2 700 N / 1 400 N |
| Cycles per hour at rated force | 41 |
| Protection rating | IP44 |
| Operating temperature | −20 to +50 °C |
| Insulation class | F |
| Approximate service life | 80 000 to 250 000 cycles depending on load |
| Dimensions L × W × H | 1 200 × 128 × 150 mm |
| Motor weight | 15 kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]