NICE Toona TO4005 – standalone 230 V motor for a gate leaf up to 3 m
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€281.83 including VAT
| Weight |
|---|
| 10 kg |
Description of NICE Toona TO4005 – standalone 230 V motor for a gate leaf up to 3 m
NICE Toona 4 TO4005 is a standalone 230 V AC motor for one gate leaf. According to the NICE chart, at a length of 3 m, it can handle approximately 300 kg at most; the weight of 500 kg applies at lengths up to approximately 1.8 m. The operator is non-reversible, has a 7 µF capacitor and an opening limit microswitch. The control unit and accessories are included only in the selected kit.
Choose a compatible control unit to go with the motor's 230 V AC voltage.
| Quick navigation on this page | ||
|---|---|---|
| Selection and limits | Service life | Kits |
| Package contents | Accessories | Manual |
| Installation | Wiring | Connecting accessories |
| Specifications | Maintenance | Release |
Accessories compatible with the NICE Toona 4 TO4005 operator
Use the listed accessories according to the terminals and outputs on the actual control unit. Current TO4005 kits include MC800; older kits may have a different board. Check the specific wiring before installation.
We also recommend purchasing these optional accessories compatible with the operator:
| What | Why | Type |
|---|---|---|
Control unit |
The operator's control electronics. |
|
| Signals gate movement. Only models explicitly listed as having an antenna include one; choose a light based on the output of the control unit being used. |
| |
Monitor the space between the transmitter and receiver. If the beam is interrupted, they send a signal to the control unit; the response depends on the wiring and settings. Test the safety of the entire gate after installation. For MC800 BlueBUS and contact photocells connect to different inputs. | ||
Contact photocells | Connect relay photocells with a suitable contact to the corresponding input on the actual control unit. | |
| Choose one based on the receiver in the specific kit and the required coding. | ||
| The receiver and transmitter must use the same coding; see the kit table for the equipment included in the available kits. |
|
|
|
For improved remote-control range. |
||
|
Useful if you forget your remote, if many vehicles or people visit your property, or if you don't want to give everyone a remote or open the gate manually. |
||
|
Control the gate with a key using a switch connected to the control unit by cable from any convenient location. |
||
|
Operate the drive by presenting a card or key fob to the card reader. |
|
|
| The lock holds the gate leaf in the closed position. The control unit must release it before opening; check suitability and voltage against the gate and the specific control unit. |
|
Choosing a drive for TO4005
Gate leaf length and weight limits
The NICE graph for Toona 4 allows approximately 500 kg with a gate leaf length of up to 1.8 m and 300 kg at 3 m. Between these points, the permitted weight decreases as the leaf length increases. Also account for smooth gate-leaf movement, solid infill and wind.
Estimated service life
Service life is estimated based on the load index, not a guaranteed number of cycles. Add the relevant values from the table, then read the result from the original NICE graph.
| Service life graph |
|---|
When calculating, use the weight of one gate leaf. For example, at 250 kg, 2.5 m and with no additional factors, the index is 10 % + 20 % = 30 %; read the estimated number of cycles from the graph.
Standalone motor and kits
This page is for ordering one TO4005 drive. The original NICE manual shows the mounting brackets, fasteners and keys supplied with each specific package. Before installation, check that the delivery is complete against the manufacturer's Figure 1. The drive alone, without a control unit and the required safety devices, does not make a complete automation system.
Compatible control units
- Current control unit supplied in the kits: NICE MC800 (MCA5R30 board), replacing the older models listed below.
- For one motor: NICE MC200 is still available for sale.
- Older compatible models, no longer manufactured: NICE Mindy A60, NICE A400, NICE-A6, NICE-A6F. For an existing installation, refer to the manual for the actual control board.
Kits with TO4005 motor
| Basic kit – 1 leaf | Basic kit – 2 leaves |
|---|---|
| 1 × TO4005, 1 × MC800, 1 × MYGO4, 1 × OXIBD. Contents and price » | 2 × TO4005, 1 × MC800, 1 × NICE remote control, 1 × OXIBD. Contents and price » |
| Kit with photocells – 1 leaf | Kit with photocells – 2 leaves |
| 1 × TO4005, 1 × MC800, 1 × MYGO4, 1 × OXIBD, 1 pair of EPM. Contents and price » | 2 × TO4005, 1 × MC800, 1 × NICE remote control, 1 × OXIBD, 1 pair of EPM. Contents and price » |
| Kit with accessories – 1 leaf | Kit with accessories – 2 leaves |
| 1 × TO4005, 1 × MC800, 1 × MYGO4, 1 × OXIBD, 1 pair of EPM, 1 × ELAC. Contents and price » | 2 × TO4005, 1 × MC800, 1 × MYGO4, 1 × OXIBD, 1 pair of EPM, 1 × ELAC. Contents and price » |
Installing the TO4005 gate operator
Before fastening, check that the post, its foundation and anchoring can withstand the loads from the gate leaf, operator and wind. The profile dimensions alone do not determine suitability; material, wall thickness, height, hinge position and foundation condition also matter.
If the hinge position and post shape do not allow the dimensions shown in the installation chart, modify the rear bracket or use extended PLA6 bracket. Determine dimensions A and B from the measured value of C and the required opening angle using the NICE installation chart. For opening outwards, an extended rear bracket is required; determine its length from the chart and check that the gate leaf can move freely.
Before fastening, also check that the gate leaf moves smoothly and stays a safe distance from fixed obstacles. The front and rear brackets have a height difference of F = 34 mm.
I. Installing the rear mounting bracket
Calculate the position of the rear bracket using the chart, which shows the dimensions A and B and the maximum opening angle. Please note that values A and B must be similar (ideally identical) for the operator to move smoothly in a straight line.
Example of reading values from the chart
Calculation procedure:
- Measure the distance C from the diagram
- On the chart draw a horizontal line that intersects the measured value of C
- The intersection of this line with the DIL (Recommended Installation Line) indicates the maximum opening angle
- If the intersection is below level t, you will need to adjust the values so that the intersection moves above this level
- If the intersection is above level t, everything is fine, but if the specified maximum opening angle is unsuitable, you will need to adjust the value of A and, if necessary, the value of B, so that they are similar (ideally identical)
Before fastening the bracket to the post or wall, shorten it to the required length to match dimensions A and B and weld it to the mounting plate.

1. Cut the bracket to the required length

2. Weld the shortened bracket to the mounting plate
The standard rear bracket supplied is 150 mm long. Before welding it, compare its available length with the dimensions in the installation chart; if it is not long enough, use a suitably extended bracket.
Before fastening the rear bracket, check that the front bracket will sit on a solid part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.
Difference F = 34 mm.
If everything is suitable, fasten the rear bracket to the post or wall using screws, wall plugs and washers.
II. Installing the front mounting bracket
The front bracket must be mounted on the gate leaf at a distance determined by the values D and E, which you read from the table (the value D is fixed at 730 mm):
| A (mm) | E (mm) |
|---|---|
| 100 | 630 |
| 110 | 620 |
| 120 | 610 |
| 130 | 600 |
| 140 | 590 |
| 150 | 580 |
| 160 | 570 |
| 170 | 560 |
| 180 | 550 |
| 190 | 540 |
| 200 | 530 |
| 210 | 520 |
The supplied package includes a weld-on bracket. If you would prefer a screw-on bracket, we recommend ordering the alternative NICE PLA8 screw-on bracket.
- Calculate from the table the value E
- Calculate the height according to the diagram bracket heights (view image)
- Attach the bracket to the gate leaf (if welding it on, we recommend tack-welding it for now only)
III. Mounting the gate operator on the rear bracket
- Attach the motor to the bracket as shown, using the supplied rear bracket pin, washer and nut.
- Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can pivot
IV. Mounting the gate operator on the front bracket
- Attach the operator to the bracket as shown, using the supplied pin and washer.
- Tighten the pin fully
V. Microswitch stop for the open position
TO4005 is one of the 230 V Toona 4 models with a mechanical stop and microswitch. When the stop is contacted, the microswitch interrupts the power supply to the motor. Set and test the end position according to the original drawing and the control unit used; do not apply the procedure for the 24 V mechanical stop without checking first.
TO4005 motor wiring
The motor has AP / COM / CH connections and a separate protective earth connection. Wire it only with the power disconnected, following NICE figure 15 and the instructions for the actual control unit. Check the direction of travel, end-position microswitch and safety devices when testing the complete gate.
Control unit MC800 is used only in configurations that actually include it. The motor's 230 V rating alone does not indicate the voltage of the photocell, warning light or control outputs.
Wiring accessories with the MC800 control unit and MCA5R30 board
The following wiring applies to the MC800/MCA5R30 in current TO4005 kits. The accessory terminals belong to the control unit, not the motor itself. For a different control unit, use its own wiring diagram. Disconnect the mains power before starting work.
| Accessories | Terminals, power supply and polarity |
|---|---|
Auxiliary power supply | On the MCA5R30, terminal 3 = 0 V (−) and terminal 4 = +24 V DC and the common connection for the inputs. The total current limit for powered accessories is 200 mA; check the current draw and permitted voltage of each product. |
EPM relay photocells | With Standby disabled and without photocell testing, power the TX transmitter and RX receiver from terminal 4 (+24 V DC) and terminal 3 (−). Connect the voltage-free C–NC contact of the receiver between 4 (common) and the relevant input 8/PHOTO, 9/PHOTO1 or 10/PHOTO2. The contact has no +/− polarity. The AUX inputs must be set to relay photocell mode; in limit-switch mode they have a different function. |
EPM with Standby enabled | According to the MCA5R30 wiring diagram, power both TX and RX between terminal 4 (+24 V DC) and terminal 5 (OutSTB, switched return line). On EPM photocells, 1 = +, 2 = return line. OutSTB is 24 V, maximum 4 W and switches off in Standby; do not use terminal 5 as a permanent negative connection. Connect the RX C–NC contact between terminal 4 and the relevant PHOTO input. |
EPM with photo-test | Wire according to the photo-test diagram TX 1 → 4 (+24 V DC), TX 2 → 5 (OutSTB). The receiver is powered continuously: RX 1 → 4 (+), RX 2 → 3 (−). The RX C–NC contact remains connected between terminal 4 and the relevant PHOTO input. Do not overload OutSTB or use it simultaneously for another load; after wiring, perform device learning and test the safety function. |
BlueBUS photocells | Compatible EPMB connect using two wires to BlueBUS terminals 6 and 7. + and − are not polarity-sensitive. Set the address and run device learning after adding or removing an element. |
STOP and command contacts | Voltage-free input 12/STOP accepts NO, NC or 8.2 kΩ, depending on the connected device; the state is learned. 13/SbS, 14/OPEN and 15/CLOSE use an NO contact connected to terminal 4 (common). These contacts have no +/− polarity; do not apply an external voltage to the inputs. This also applies to key-switch or external receiver relays. |
ELAC warning light | NICE ELAC connect to the FLASH output intended for a standalone flashing lamp: switched 120/250 V AC, maximum 21 W. This is a mains output; it has no +/− polarity. Do not confuse it with the 24 V accessory terminals. |
Electric lock | Terminals 1–2 / EL: 12 V AC, maximum 15 VA. The AC output has no +/− polarity; check the lock specifications. |
Radio receiver | OXIBD is installed in the SMconnector; do not use power terminals 3/4 or BlueBUS for it. Connect the antenna as specified for the receiver, not to the motor terminals. |
If AUX inputs 8–11 are used for limit switches, their function differs from that of the PHOTO inputs; the microswitch in the TO4005 motor does not by itself determine the AUX setting on the control unit. If you change the photocells or wiring, repeat the relevant learning procedure and test the gate’s stopping and response. For detailed instructions, see MC800 control unit manual.

Relay photocells in Standby mode

Relay photocells with photo-test
Manual release during a power failure
- Slide the lock cover on the drive aside.
- Insert the release key, turn it and pull out the lever.
- Move the gate leaf slowly by hand. When finished, re-engage the drive and check that it is engaged.
The procedure corresponds to original NICE illustration 16. Move the gate leaf by hand only after disconnecting the power supply and confirming that it can move safely.
Technical specifications
Model | NICE Toona 4 TO4005 |
|---|---|
Application | Electromechanical operator for swing gates |
Motor power supply | 230 V AC / 50 Hz |
Maximum / rated current draw | 1.5 A / 1 A |
Maximum / rated power input | 340 W / 180 W |
Built-in capacitor | 7 µF |
Stroke | 385 mm |
Speed unloaded / under load | 0.016 / 0.012 m/s |
Maximum / rated force | 1,800 N / 600 N |
Cycles per hour at rated force | 58 |
Protection / insulation | IP44 / class F |
Thermal protection | 140 °C |
Operating temperature | −20 to +50 °C |
Dimensions (L × W × H) | 820 × 115 × 105 mm |
Drive weight | 6 kg |
Safety and maintenance
Before commissioning, check the gate leaf movement, stop, direction of travel, photocells and other safety devices. The motor has no force adjustment of its own; this is handled by the control unit. NICE requires scheduled inspection of the operator at least every 6 months, including checks of the fixings, lead screw and operation.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]