Description of NICE Toona TO5024I – standalone 24 V swing gate operator for gates up to 5 m, according to the load chart

NICE Toona TO5024I is a standalone 24 V DC motor for one gate leaf. NICE describes it as a version for intensive use; compared with the TO5024, it has a higher rated force and is rated for 75 cycles per hour at rated force. The 5 m length and 600 kg weight are maximum figures; the permissible combination is shown in the graph for the specific model.

24 V indicates the motor voltage. The mains supply, radio, safety devices and position learning are determined by the control unit actually installed. For the current MC824HR30/MCA1R30 use its own manual; for the older MC824HR10, follow the instructions for the MCA1R10 board.

Quick navigation
Package contentsLimits
Service lifeInstallation
WiringStop
AccessoriesControl unit
Manual releaseSpecifications
MaintenanceManual
Accessories – terminals and polarityPDF manual

  • Non-reversible
  • 24 V
  • Magnetic encoder
  • With an opening stop
  • Version for intensive use according to NICE

What is included with the standalone operator

Included according to NICEPurpose
TO5024I motorDrives one gate leaf.
Front and rear brackets with mounting plateAttachment to the gate leaf and post.
Fasteners and release keysMounting the operator on the brackets and manual operation during a power failure.

The exact number of parts depends on the version supplied; check the package against figure 1 in the NICE manual. Anchor bolts and wall plugs for the post or wall are supplied separately, depending on the substrate. Select the control unit and safety accessories to suit the specific system.

Operating range

TO5024I: at 5 m, the graph shows approximately 250 kg; the 600 kg limit applies only up to approximately 1.8 m. Also assess operating resistance, the gate leaf infill and wind exposure. The graph shows the operating limit, not a guarantee of service life.

NICE Toona 5 – limits, TO5024I curve

Service life by load

For each gate leaf, add the relevant indices for weight, length and environmental conditions. Read the approximate number of cycles from the original graph. This calculation is the manufacturer's estimate, not a guarantee of service life.

Features of the complete automation systemIndexService life graph
Weight up to 300 kg
0%

NICE Toona – approximate service life graph by load index

Over 300 up to 400 kg
10%
Over 400 up to 500 kg
20%
Over 500 kg
30%
Length 2–3 m
0%
Length over 3 up to 4 m
10%
Length over 4 up to 5 m
20%
Temperature above 40 °C, below 0 °C, or humidity above 80%
20%
Solid gate leaf infill
15%
Windy area
15%

NICE graph


Compatible control units

Current: MC824HR30/MCA1R30. Older compatible system: MC824HR10/MCA1R10; use the manual for the specific board. The motor is also sold separately, so check the contents to confirm which control unit is included in a specific kit.

I. Installing the rear mounting bracket

Bracket mounting: For a typical steel structure, a 120 × 120 mm post is recommended as a guideline. A 100 × 100 mm profile may be used after assessing the material, wall thickness, height, foundation, anchoring and wind load. The post dimensions alone do not confirm that the installation will be strong enough.

Measure the hinge offset C; determine from the original installation chart B, the opening angle and A. A and B should be similar; values of B below the line t are not recommended by NICE. If the post or hinge offset does not allow the geometry to be maintained, adjust the bracket or use the extended rear bracket PLA6. For outward opening, an extended rear bracket is required; determine the dimensions based on the actual gate. Before welding, measure the supplied brackets and check the full range of gate-leaf movement.

Diagram: inward opening
Diagram: inward opening

Outward-opening diagram
Outward-opening diagram

The position of the rear bracket determines the achievable opening angle and the load on the motor. Read dimensions A/B/C from the graph explicitly marked TO5024I; do not shorten or weld the bracket before checking the complete geometry.

NICE Toona 5 mounting graph for TO5024I
NICE Toona 5 mounting graph for TO5024I

NICE Toona – example of reading dimensions C, B and A from the mounting graph
Example of reading A/B/C

Calculation procedure:

  1. Measure C as shown in the gate diagram.
  2. On the graph, draw a horizontal line from C and read off B.
  3. The intersection with the recommended r.i.l. line indicates the maximum angle; read off A using a vertical line.
  4. If the angle is unsuitable, adjust A and, if necessary, B so that they are approximately equal. Do not use a B value below line t.

Before fixing the rear bracket, transfer dimensions A and B from the graph to the actual gate. If the supplied bracket needs shortening, modify it only after checking the geometry, then securely join it to the mounting plate.

1. Cut the bracket to the required length
1. Cut the bracket to the required length

2. Weld the shortened bracket to the mounting plate
2. Weld the shortened bracket to the mounting plate

The supplied Toona 4–5 series rear bracket is 150 mm long. For a greater hinge offset or outward opening, use PLA6 and check the bracket positions against the graph again.

Before attaching the rear bracket, check that the front bracket will sit on the solid part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.

Height difference F = 34 mm is specified by NICE for the Toona 4–5. Before final fixing, measure the brackets actually supplied and check that the gate leaf moves freely throughout its full travel.

NICE Toona – bracket height difference F = 34 mm
NICE Toona – bracket height difference F = 34 mm

After checking the geometry, securely fasten the rear bracket to the post or wall using screws, wall plugs and washers suitable for the substrate material. These fixings are not included with the motor.

II. Installing the front mounting bracket

Position the front bracket on the gate leaf at the fixed mounting dimension D = 880 mm. Read the value E from the table for the dimension A selected when mounting the rear bracket.

A (mm)E (mm)
100780
110770
120760
130750
140740
150730
160720
170710
180700
190690
200680
210670
220660
230650
240640
250630
260620
270610
280600

The supplied front bracket is designed to be welded on. If it needs to be bolted on, use a suitable NICE PLA8 bracket.

  1. Read the value E from the table for the selected A.
  2. Fit the front bracket with a height difference of F = 34 mm according to the NICE drawing.
  3. Attach the front bracket to the solid part of the gate leaf; if welding, tack it in place first and check the movement again before completing the weld.

III. Mounting the gate operator on the rear bracket

Mounting the NICE Toona operator on the rear bracket
Mounting the NICE Toona operator on the rear bracket

  1. Attach the motor to the bracket as shown, using the supplied rear bracket pin, washer and nut.
  2. Tighten the nut fully, then loosen it by 1/10 of a turn, leaving the minimum clearance between the parts as specified by NICE.

IV. Mounting the gate operator on the front bracket

Mounting the NICE Toona operator on the front bracket
Mounting the NICE Toona operator on the front bracket

  1. Attach the operator to the bracket as shown, using the supplied pin and washer.
  2. Tighten the front fixing fully as shown in the NICE installation drawing.

V. Adjusting the mechanical travel stop

TO5024I has an internal mechanical opening stop. When adjusting it, observe the range marked on the NICE drawing as 100 mm max. Set the closed position and any required external stops based on the complete gate and the control unit installed.

Setting the NICE Toona operator’s mechanical travel stop
Setting the NICE Toona operator’s mechanical travel stop

  1. Release the operator according to the operator release instructions
  2. Loosen the mechanical stop screw
  3. Manually move the gate leaf to the required open position
  4. Slide the entire mechanical stop against the pin and tighten the screw as shown
  5. Manually move the gate leaf to the closed position and re-engage the operator

Motor wiring and connections

Disconnect the power supply before making connections. 24 V DC is the motor voltage; the control unit supply and accessory outputs must be considered separately. The motor has a separate pair of motor wires and a pair for the encoder. For series 4–5 operators, the terminals are labelled as shown; for series 6–7, use its separate diagram. Determine the connections on the control board solely from the actual board installed in the system. For a gate that opens outward, NICE specifies reversing the polarity of the motor supply; do not connect the encoder as the motor power supply.

NICE Toona TO5024I motor terminal diagram

Original NICE wiring diagram for the Toona TO5024I motor

After wiring, check the direction of travel, stop positions and safety devices according to the manual for the specific control unit.

Pre-start check

Before switching on, release the operator and move the gate leaf through its full travel. It must move smoothly, without catching, and the brackets and post must remain secure.

  1. After wiring according to the actual control unit, check the direction of travel and set the positions as described in its manual. Force adjustment is made on the control unit, not on the motor itself.
  2. Test the opening stop, safety photocells, any safety edges, the STOP control and the manual release. Check that operating forces are safe and, if there is a pedestrian gate in the gate leaf, that the operator is interlocked when it is open.
  3. Give the customer the release procedure and the manual for the control unit actually installed.

Connecting accessories to the MC824HR30

The following terminals belong to the MC824HR30/MCA1R30 control unit when used with a TO5024I motor, not to the motor itself. Disconnect the mains supply and backup battery before working. For a different board, use its own wiring diagram.

AccessoriesTerminals, voltage and polarity
BlueBUS photocellsConnect compatible photocells, such as EPMB, using two wires, to BlueBUS. There is no +/− polarity. Set the address and repeat the learning procedure after changing devices.
STOP and command inputsThe STOP input accepts a volt-free NO or NC contact, or an 8.2 kΩ resistive device 8.2 kΩ; its state is learned. SbS, Open and Close accept a volt-free NO contact on the corresponding pair of terminals. Contacts have no +/− polarity; do not apply an external voltage to the input.
Auxiliary power supplyRight-hand terminal of the STOP pair = −; left-hand terminal of the SbS pair = +, when viewed in the orientation shown in the diagram below (labels above the terminals). Power supply for a compatible reader or module: 24 V DC (−30% to +50%), maximum 200 mA, including in Stand-by mode. Wire the module’s command relay separately as a volt-free contact; check the module’s permitted voltage range and current consumption.
Flashing light, lock, indicator lightFLASH: 12 V DC, maximum 21 W; ELS: 12 V AC, maximum 15 VA, with no fixed +/− polarity; OGI: 24 V DC, maximum 4 W. For FLASH/OGI, the diagram does not specify the +/− order on the pair of terminals, so do not guess it; for a polarised product, check the markings on both the board and the product. The output functions may change depending on programming.
Radio receiver and backup batteryThe plug-in receiver fits into the SM, and the backup battery connects to its designated connector according to the board installed. They do not connect to BlueBUS or to the motor terminals.

MC824HR30: the right-hand STOP terminal is negative; the left-hand SbS terminal is positive

For detailed terminal locations, the learning procedure and testing of safety devices, see the manual for the MC824HR30 control unit itself.

Older MC824HR10/MCA1R10 system

For a kit with this board, use the R10 diagram. For auxiliary equipment, the manufacturer specifies STOP = −, SbS = +, 24 V DC, maximum 200 mA including in Stand-by mode. However, the original R10 diagram does not separately identify the specific power terminal in the STOP/SbS pair. Connect the auxiliary power only after confirming the relevant terminal on the actual board; do not assume the R30 terminal location applies here. Wire the relay command separately to the SbS pair as a volt-free NO contact; do not apply an external voltage to the input. MC824HR10 manual in Slovak.

DeviceConnection to MCA1R10
BlueBUSTwo wires to BlueBUS; no +/− polarity. Repeat the learning procedure after changing addressed devices.
STOP and command inputsSTOP: NO, NC or 8.2 kΩ; SbS, OPEN, CLOSE: volt-free NO contact on the corresponding pair of terminals. Contacts have no +/− polarity.
OutputsFLASH: 12 V DC, maximum 21 W; ELS: 12 V AC, maximum 15 VA, no +/− polarity; OGI: 24 V DC, maximum 4 W. For a polarised FLASH/OGI device, determine +/− from the markings on the actual board and device; the diagram does not specify their order.
Radio receiver and backup batteryThe receiver fits into the SMconnector; for R10, the manufacturer specifies the backup battery PS324 with its own connector. Do not use the R30 battery or cable here.

Original MC824HR10 diagram: BlueBUS, STOP, SbS, Open, Close and outputs

Before connecting, check the label and wiring diagram for the board actually installed. The learning procedure for this board differs from the newer MCA1R30.

Compatible accessories

Select accessories according to the specific control unit and receiver. The interfaces for the following types are listed; wireless and command devices may require additional accessories or configuration.

What Why Type
Control unit Motor control electronics; choose the manual for the board actually installed.
Flashing light Signals movement. Only models specified by the manufacturer include an antenna. The choice depends on the control unit output.
  • LED flashing light with antenna ELDC
  • Multifunction light WLT

On the MC824HR30, the FLASH output is intended for a 12 V flashing light rated up to 21 W. For a different light, check the voltage, power consumption and flashing mode.

Photocells They monitor the beam path and send a signal to the control unit. The gate response depends on the wiring and settings; test the complete system after installation.
Transmitter Choose a remote control according to the receiver and coding installed in the control unit. ON3EBD is paired with OXIBD, and ON3ELR with OXILR.
Receiver The radio receiver must support the remote control's coding; smart home interfaces have different functions.
  • BiDi-WiFi – Bus-T4 interface for configuration; available control functions depend on the board and app.
  • BiDi-ZWave – Z-Wave interface.
  • Wired Wi-Fi module, for example Zamel, connect only to a suitable command input. SUPLA app: Android / iOS.
  • GSM receivers: GSM modules Connect them using a suitable control contact, according to the input on the control unit in use.
Antenna Improves receiver reception when correctly positioned and connected.
  • Integrated into the beacon ELDC
  • External antenna ABFKIT
Keypad Code-controlled operation. A BlueBUS keypad requires a control unit board that supports command devices.
Key switch Operation via a suitable control input on the control unit.
  • Surface-mounted, standard cylinder EKS
  • Surface-mounted, European cylinder EKSEU
  • Flush-mounted, standard cylinder EKSI
  • Flush-mounted, European cylinder EKSIEU
Electric locks Secures the gate leaf; check the lock's control method and voltage against the control unit and installation.
Card readers ETPB requires the specific control unit board to support BlueBUS command devices.
  • ERA Transponder Reader ETPB
Backup power supply A battery connected to a compatible control unit enables operation during a power outage.
  • PSS324 is the current type for MC824HR30.
  • Older PS324 requires, for R30, CABLA11 and standby mode disabled. Check the conditions in the manual for the installed control unit board.

Manual drive release

Release or engage the drive only when the gate leaf is stationary. If the gate has an electric lock, unlock it first. In the event of a fault, disconnect the power supply.

  1. Slide back the protective cover, insert the supplied key and turn it clockwise.
  2. Lift the release lever and move the gate leaf manually.
  3. To engage the drive again, lower the lever, turn the key counterclockwise, remove it and close the cover.

NICE image: manual release of the Toona drive

Before restarting, check that the drive is engaged and that no one is in the gate's path.

Inspection and maintenance

Carry out maintenance at least every 6 months: after disconnecting the power supply, check the fastening, corrosion, wear and lubrication of the screw and nut. Then test the movement, release mechanism and safety devices of the entire gate.

Technical specifications

ParameterValue
Model
TO5024I
Drive motor
24 V DC
Maximum / rated current draw
5 A / 2.2 A
Maximum / rated power input
120 W / 60 W
Stroke
540 mm
0.013 m/s
0,013 m/s
0.010 m/s
0,010 m/s
Maximum / rated force
2 200 N / 800 N
Cycles per hour at rated force
75
Protection rating
IP44
Operating temperature
−20 to +50 °C
Insulation class
F
Approximate service life according to NICE
80 000 to 250 000 operating cycles
Dimensions L × W × H
965 × 115 × 105 mm
Motor weight
8 kg

The motor weight in the table is the NICE specification excluding packaging. The weight for the variant ordered also includes packaging and is used to calculate shipping costs.

Slovak-Czech NICE Toona installation manual. Programming, position learning and accessories are covered in the manual for the actual control unit.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Toona TO5024I – standalone 24 V swing gate operator for gates up to 5 m, according to the load chart

Product: NICE Toona TO5024I – standalone 24 V swing gate operator for gates up to 5 m, according to the load chart
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.