NICE Toona TO4024 – standalone 24 V motor for a gate leaf up to 3 m
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€170.38 including VAT
| Weight |
|---|
| 8,40 kg |
Description of NICE Toona TO4024 – standalone 24 V motor for a gate leaf up to 3 m
NICE Toona 4 TO4024 is a standalone 24 V DC motor for one gate leaf. According to the NICE chart, at a length of 3 m it can handle a maximum of approximately 300 kg; the weight of 500 kg applies at a length of up to approximately 1.8 m. Consider the length and weight together.
The drive is non-reversible, uses an encoder and has an adjustable mechanical opening stop. For current standard TO4024 kits, the catalogue lists MC824HR30. Mains power, BlueBUS, the radio receiver and battery are features of the selected control unit, not of the motor itself.
Toona has a two-piece die-cast aluminium body with a surface finish, internal parts made of steel, alloys and technopolymers, and a bronze lead nut. The mounting dimensions are compatible with older NICE Moby and Pluto drives. The motor is also suitable for more frequent use; with a solid infill and in a windy location, take the higher operating load into account when selecting according to the service life chart.
With a setup using MC824HR30 position learning, diagnostics, slowdown, pause time and pedestrian access are control unit functions. It uses BlueBUS for compatible safety devices.
| Quick navigation on this page | ||
|---|---|---|
| What’s included | Selection and limits | Kits |
| Accessories | Manual | Service life |
| Installation | Wiring | Stop |
| Photo gallery | Release | Specifications |
Accessories compatible with the NICE Toona 4 TO4024 drive
We also recommend purchasing the following compatible optional accessories for the drive:
| What | Why | Type |
|---|---|---|
|
Control unit
|
The drive’s control electronics. |
|
| Signals that the gate is moving. Only the model explicitly specified as including an antenna has one; the choice of light depends on the output of the control unit being used. |
The FLASH output on MC824HR30 is intended for a 12 V light, up to 21 W. Choose another flashing light only after checking the voltage, power type, power consumption and flashing mode. |
|
| Monitor the area between the transmitter and receiver. When the beam is interrupted, they send a signal to the control unit; its response depends on the wiring and settings. After installation, test their correct positioning and operation together with the complete gate. | ||
| Choose a remote control based on the receiver and coding used in the specific control unit. | ||
| The receiver must support the encoding used by the selected transmitter; OXIBD and OXILR are not interchangeable with all the listed remote controls. |
|
|
| For better remote-control range. | ||
| If you forget your remote control, or have many vehicles/users and don’t want to issue a remote control to everyone. | ||
| Operate the gate with a key via a switch wired to the control unit. | ||
|
Electric locks
|
The lock holds the gate leaf in the closed position. The control unit must release it before opening; select the appropriate model and voltage for the gate and specific control unit. |
|
| Operate the gate opener by presenting a card or key fob to the reader. |
|
|
| In the event of a power failure, it powers the automation system via a compatible control unit; the choice depends on the revision of the control board. |
|
| The gate opener includes: | Code | |||
|---|---|---|---|---|
![]() |
1 × | NICE Toona 4 TO4024 motor |
TO4024 |
|
|
Toona 4 electromechanical motor; approximately 500 kg for a gate leaf up to 1.8 m long, or 300 kg at 3 m, according to the NICE chart. |
||||
![]() |
1 × | Internal mechanical opening stop | PLA13 | |
|
The internal stop is used to set the open end position. Provide mechanical locking of the gate in the closed position according to the specific installation. |
||||
![]() |
2 × | Release key | CM-B | |
|
In the event of a power failure, it releases the gate opener so the gate can be moved manually by pushing or pulling. |
||||
![]() |
1 × | Weld-on front bracket | PMDSMAR04.4610 | |
|
Weld it to the fixed part of the gate leaf. Note that it is installed at a different height than the rear bracket. An alternative screw-on bracket is the PLA8. |
||||
![]() |
1 × | Front bracket pin | R8.5120 Washer V8X10.5102 Pin |
|
|
Used to attach the front of the gate opener to the front bracket. |
||||
![]() |
1 × | Weld-on rear bracket | PMDSMP.4610 | |
|
It is welded to the mounting screw plate or steel post. Note: it is installed at a different height than the front bracket. The alternative extended bracket is PLA6. |
||||
![]() |
1 × | Mounting plate for the rear bracket | PMDPA.4610 | |
|
The rear bracket is welded to it. The mounting plate is then fastened to a post or wall. |
||||
![]() |
2 × | Rear bracket pin | D10.5110 Nut R10.5120 Washer V10X40.5101 Pin |
|
|
Used to secure the rear of the drive to the rear bracket. |
||||
![]() |
1 × | NICE Toona 4 TO4024 installation manual | Download | |
|
Slovak and Czech installation manual for the Toona motor. Refer to the control unit's own manual for wiring and programming instructions. |
||||
Important: A standalone TO4024 requires a compatible control unit, such as MC824HR30, and safety devices suitable for the installation. Find the equipment and price of a complete automation system in the kits featuring this motor.
(Is this drive right for me?)
Compare it with other drives:
For older models, check current availability and compatibility of the mounting dimensions.
Special-offer kits containing a drive NICE Toona 4 TO4024:
| Kit for a single-leaf gate » | Kit for a double-leaf gate » |
|---|---|
|
Toona drive, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver. |
2 x Toona drives, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver. |
| Kit for a single-leaf gate with photocells » | Kit for a double-leaf gate with photocells » |
|
Toona drive, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver, photocells, warning light. |
2 x Toona drives, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver, photocells, warning light. |
| Kit for a single-leaf gate with accessories » | Kit for a double-leaf gate with accessories » |
|
Toona drive, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver, photocells, warning light. |
2 x Toona drives, max. 500 kg at 1.8 m or 300 kg at 3 m, control unit, remote control, receiver, photocells, warning light. |
In kits with MC824HR30, remote control pairing is handled by the receiver and the procedure for this control unit. For a different control board, use its own procedure.
Choosing a drive – is the NICE Toona 4 TO4024 suitable for my gate?
Leaf length and weight limits
Assess the length and weight of one leaf together, using the NICE graph. For a length of up to 1.8 m the leaf can weigh approximately 500 kg; at a length of 3 m approximately 300 kg. The 3 m and 500 kg values do not apply at the same time. For other dimensions, read the permissible weight from the graph and also take into account a solid infill, wind, and smooth gate movement.
NICE Toona 4 TO4024 operator lifespan
The lifespan is an estimate based on the stress index, not a guarantee of the number of cycles. Add the applicable values from the table, then read the result from the original NICE graph.
| Lifespan graph |
|---|
When calculating, use the weight of one gate leaf. For example, at 250 kg, 2.5 m, and with no other factors, the index is 10 % + 20 % = 30 %; read the estimated number of cycles from the graph.
Installing the NICE Toona 4 TO4024 operator
Before mounting, check that the post, its foundation, and anchoring can withstand the loads from the gate leaf, operator, and wind. The profile dimensions alone do not determine suitability; material, wall thickness, height, hinge position, and foundation condition also matter.
If the hinge position and post shape do not allow the dimensions shown in the installation graph, adjust the rear bracket or use the extended PLA6 bracket. Determine dimensions A and B from the measured C and the required opening angle using the NICE installation graph. Opening outwards requires an extended rear bracket; determine its length from the graph and check that the gate leaf moves freely.
A typical (optional) operator wiring arrangement with accessories looks as follows:
Accessories list
|
NICE Toona TO4024 operator wiring
With both the mains supply and backup battery disconnected, route the cable through the operator cable entry. The TO4024 has marked + / − motor terminals and a separate pair of encoder terminals; their location is shown in the image below. With the current MC824HR30 control unit, connect the single motor to M2 and its encoder to motor 2 ENC; leave M1 unused. The encoder has no specified polarity. The M2 output is for the motor, not for powering accessories. For two motors or a different control unit, follow the diagram for the board actually installed. After wiring, perform the specified learning procedure and check the gate's direction and safe operation.
Board wiring and setup MC824HR30 use only in an assembly fitted with this exact control unit.
Accessory wiring for the MC824HR30
The following terminals belong to the MC824HR30 control unit, not the TO4024 motor. Connect them only when both mains and battery power are switched off. For a different board, use its own wiring diagram.
| What | Wiring and polarity |
|---|---|
|
Photocells and BlueBUS devices
|
A compatible pair, such as EPMB, is connected with two wires to the BlueBUS. + and − are not polarity-sensitive. Set the photocell address and run device learning after adding or removing a device. |
|
Key switch or receiver relay
|
Volt-free contact NO connect it to the pair of terminals SbS (step-by-step command), or to the pair of terminals Open or Close depending on the required command. Do not apply an external voltage to the command input. |
|
Safety edge / STOP
|
The STOP input accepts an NO or NC contact, or an output with a resistance of 8.2 kΩ. After changing the wiring, run the learning procedure; the contact type must match the device actually installed. |
|
ELDC warning light
|
Connect to the FLASH: in warning-light mode 12 V DC, max. 21 W. For accessories marked +/−, follow the markings and wiring diagram on the control board. |
|
Electric lock
|
Output ELS is in lock mode 12 V AC, max. 15 VA. The AC output has no fixed +/− polarity; check the lock’s label to ensure it is compatible. |
|
Gate-open indicator light
|
Output OGI is intended for 24 V, max. 4 W. For a polarized indicator light, follow the markings on the board and the indicator. |
|
Power supply for reader / external module
|
Auxiliary power supply: terminal STOP = −, terminal SbS = +, total max. 200 mA. The voltage is 24 V DC with a tolerance of −30% to +50%; check the module’s permitted voltage and current draw before connecting it. Wire its command relay contact separately as a voltage-free contact. These terminals remain powered in Stand-by mode. |
|
Radio and backup battery
|
Receiver OXIBD plugs into the connector SM; the battery PSS324 into its own connector. They are not connected to the M2 output or to BlueBUS. |
The FLASH, ELS and OGI outputs can be reprogrammed for another function. Before wiring, check the settings for the specific control unit against the MC824HR30 technical manual and test the safety devices after installation.
I. Installing the rear mounting bracket
Calculate the rear bracket position using the Graph, which shows the dimensions A and B and maximum opening angle. Note: values A and B must be similar (ideally identical) to allow the operator to move smoothly in a linear motion.
Example of reading values from the graph
Calculation procedure:
- Measure the distance C from the Diagram
- On the Graph draw a horizontal line that crosses the measured value C
- The intersection of this line with the DIL (Recommended Installation Line) indicates the maximum opening angle
- If the intersection is below level t, you will need to adjust the values to move the intersection above this level
- If the intersection is above level t, everything is fine, but if the specified maximum opening angle is unsuitable, you will need to adjust the value of A and, if necessary, the value of B, so that they are similar (ideally identical).
Before fixing the bracket to the post or wall, cut it to the required length corresponding to dimensions A and B and weld it to the mounting plate.

1. Cut the bracket to the required length

2. Weld the shortened bracket to the mounting plate
The standard rear bracket supplied in the package is 150 mm long. Before welding it, compare the available length with the dimensions in the installation graph; if it is too short, use a suitably extended bracket.
Before fixing the rear bracket in place, check that the front bracket will sit on the solid part of the gate leaf, as there is a height difference between the front and rear brackets, as shown in the illustration.
Difference F = 34 mm.
If everything checks out, fix the rear bracket to the post or wall using screws, wall plugs and washers.
II. Installing the front mounting bracket
The front bracket must be mounted on the gate leaf at a distance determined by the values D and E, which you can read from the Table (value D is fixed at 730 mm):
| A (mm) | E (mm) |
|---|---|
| 100 | 630 |
| 110 | 620 |
| 120 | 610 |
| 130 | 600 |
| 140 | 590 |
| 150 | 580 |
| 160 | 570 |
| 170 | 560 |
| 180 | 550 |
| 190 | 540 |
| 200 | 530 |
| 210 | 530 |
The supplied package includes a weld-on bracket. If you would prefer a bolt-on bracket, we recommend ordering the alternative NICE PLA8 bolt-on bracket.
- Calculate the value E from the tables for E
- Calculate the height according to the image bracket heights (view image)
- Attach the bracket to the gate leaf (if welding it, we recommend tack-welding it for now)
III. Mounting the gate operator on the rear bracket
- Attach the motor to the bracket as shown in the image, using the supplied rear bracket pin, washer and nut.
- Tighten the nut fully, then loosen it by 1/10 of a turn so that the gate operator can pivot
IV. Mounting the gate operator on the front bracket
- Attach the operator to the bracket as shown in the image, using the supplied pin and washer.
- Tighten the pin fully
V. Adjusting the mechanical travel stop
The TO4024 has an adjustable internal stop for the open position. Unlock the motor, loosen the stop screw, manually open the gate leaf to the desired position, slide the stop against the pin, and secure the screw. Then close the gate leaf and lock the motor again. Follow figure 11 in the original manual.
The TO4024 has an internal opening stop. Set the closing stop according to the gate design and the instructions for the control unit used.
NICE Toona operator photo gallery
|
Installation example |
Installation example |
Installation example |
|
Installation example |
Installation example |
Operator with cover removed |
|
Comparison of Toona 4, 5 and 7 operators |
Operator unlocked |
Underside view |
Manual release of the NICE Toona 4 TO4024 operator
In the event of a power failure, you will not be able to operate the gate using the remote control. Therefore, the operator can be released using the release key so the gate can be moved manually:
- Slide the release lock cover aside
- Insert the release key and turn it clockwise
- Pull out the release lever and you can move the gate manually
Technical specifications of the NICE Toona 4 TO4024 operator
|
Model
|
NICE Toona 4 TO4024 |
|---|---|
|
Application
|
Electromechanical operator for swing gates |
|
Motor power supply
|
24 V DC from a compatible control unit |
|
Maximum / rated current draw
|
5 A / 2 A |
|
Maximum / rated power consumption
|
120 W / 48 W |
|
Built-in capacitor
|
No |
|
Stroke
|
385 mm |
|
Speed without load / under load
|
0.016 / 0.012 m/s |
|
Maximum / rated force
|
1,800 N / 600 N |
|
Cycles per hour at rated force
|
95 |
|
Protection / insulation
|
IP44 / Class F |
|
Operating temperature
|
−20 to +50 °C |
|
Dimensions (L × W × H)
|
820 × 115 × 105 mm |
|
Drive weight
|
6 kg |
Safety and maintenance
Before installation, check that the gate leaf moves freely and smoothly and that both the leaf and post are sturdy. Disconnect the power supply before making electrical connections. After installation, check the safety devices and operating force according to the system’s manual.
NICE requires the drive to be inspected at least every 6 months: condition of the structure and screws, lubrication of the lead screw, wear, and functional tests. For control unit programming, see the MC824HR30 manual.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]