NICE ROBUS RBS800 - standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€642.98 including VAT
| Weight |
|---|
| 8,00 kg |
Description of NICE ROBUS RBS800 - standalone operator for sliding gates (A)
Operator NICE Robus RBS800 is designed for sliding gates weighing up to 800 kg and with a passage width of up to 8 m. It has a magnetic (inductive) limit switch. The operator is non-reversible. The operator is compact, safe and practical, with an impact-resistant cover, making it ideal for both residential and commercial use. 230 V power supply, 24 V DC motor. Detailed technical specifications ». Operator programming ». Download the manual ».
This product—the standalone NICE Robus RBS800 sliding gate operator (our code NICE-RBS800-A)—includes:
- Electromechanical NICE Robus RBS800 operator with a capacity of 800 kg, a maximum gate leaf length of 8 m, and an integrated (but removable) MCU1R30 control unit, with a built-in radio receiver and an “SM” connector for a plug-in receiver.
- 2 x release key for manual operation of the operator (required in the event of a power failure).
- 2x magnetic limit switch.
- Operator mounting components : anchoring hardware, mounting plate and magnetic stops for the inductive limit switch.
- Installation manual
One of the main advantages of the Robus RBS800 is its high opening and closing speed, enabled by advanced technology. It features obstacle detection and supports the connection of photoelectric safety sensors, ensuring maximum safety. It is also equipped with a temperature sensor that adjusts the operator's pulling force to the weather conditions, and is protected by a thermal fuse.
The operator's durable construction, with an IP44 protection rating, ensures a long service life. Robus RBS800 is compatible with Nice accessories. The integrated "Eye Check" system provides visual feedback via an LED indicator (red/green).
The “Slave Unit” function (master-slave mode) allows two motors to be controlled in sync, making it possible to automate a pair of sliding gates that open in opposite directions. It is also compatible with the older Robus RB400, but only versions equipped with the RBA3R10 control unit. The older RBA3/c is not compatible with RBS.
The built-in control unit makes operation easy. Programmability is one of the key features of this model.
The built-in bidirectional receiver is ready for immediate programming, making connection and operation easy.
Another advantage is the ability to add extra features via an expansion board, including lighting for a safer installation.
User-friendly BlueBUS technology simplifies the power supply and control of up to 7 pairs of photoelectric safety sensors using a two-core cable.
The operator achieves up to 90% energy savings in standby mode and is compatible with the Nice solar kit.
It features a module 4 gear wheel, compatible with the rack available in our range.
Thanks to the BiDi-WiFi module (optional accessory), the operator can be controlled using the mobile MyNice app (Android/iOS) and programmed with MyNice Pro (Android/iOS).
It features Operaand allows connection of the programming unit Oview. This unit is used for controlling, programming and diagnosing devices equipped with a BUS T4 connection. O-View connects directly to a compatible control unit using a BUS T4 cable, providing access to all the unit's parameters and allowing the device to be tailored to any requirement (such as force, speed, deceleration and similar settings). Oview also allows you, via the Opera system, to update the control unit firmware..
It is compatible with the solar system Solemyo (24V). Whenthe automation system is powered by the “Solemyo” system, it MUST NOT be powered from the mains at the same time.
Remote control compatibility:
The operator has a built-in receiver that is compatible with NICE series MYGO, ONE and INTI remote controls. The internal receiver does not support FloR or Flo coding. However, the control unit also has an SM connector for connecting a plug-in receiver, which may be useful if you have replaced your old operator with a new RBS and own older-style remote controls.
Information for owners of older NICE FLOR remote controls:
If you already own older NICE FLOR remote controls (models FLO2R-S, FLO2RE, FLO4R-S, FLO4RE), you can continue using them with the new NICE RBS. However, you will need to purchase a plug-in OXIBD receiver or one of the external receivers, such as the NICE OX2.
Extra-long range for remote controls:
The NICE RBS operator has a slot for an internal receiver, allowing you to install a NICE OXILR receiver featuring LoRa. A NICE OXIFM receiver can also be connected for extended options.
Information for owners of older NICE FLO and NICE SMILO remote controls:
If you use NICE remote controls at home with FLO or SMILO, these can also be used with the NICE RBS. However, you will need to purchase an internal receiver OXIBD, which supports fixed-code signals (FLO, SMILO). In this case, the receiver will accept only these older types of remote controls, and newer models cannot be paired at the same time.
Accessories compatible with the Nice Robus RBS800 operator
We recommend purchasing compatible optional accessories for the operator, or choosing one of our pre-assembled operator bundles at a discounted price.
| What | Why | Type |
|---|---|---|
| Flashing light | Flashes to indicate gate movement—ideal for entrances with limited visibility. Also includes an antenna for increased remote-control range. |
Alternatively, any flashing lights from other manufacturers with a 12V-24V power supply. |
| Photocells | They detect obstacles while the gate is closing and stop its movement, preventing it from hitting vehicles or people. | |
| Remote control | For remote operation of the gate. | |
| Receiver |
For remote operation of the gate. The RBS operator has an integrated radio receiver, but also allows a plug-in receiver to be connected. This makes it easy to upgrade from an older RB operator to a newer RBS without pairing the remote controls again. |
|
| Programming devices |
|
|
| Antenna | For increased remote-control range. | |
| Keypad | If you forget your remote control, or have many vehicles/users and don't want to issue a remote control to everyone. | |
| Key switch | Operate the gate with a key using a switch wired to the operator. | |
| Card readers | Operate the drive by presenting a card or key fob to the reader. | ERA Transponder Reader ETPB |
| Rack | Essential for automation—the drive cannot move the gate without a rack. | |
| Backup power supply | Keeps the gate operating during a power outage. |
Manuals and documents for download
Nice Robus RBS800 drive manual – PDF
Instructions for pairing remotes with a Nice drive – link
NICE Robus RBS800 at a glance
NICE Robus RBS is a range of non-reversible electromechanical gear drives for sliding gates. They are supplied with a built-in (removable) NICE MCU1R30 control unit with a built-in receiver and an SM connector for plug-in receivers for OXI radio signals, for example NICE OXIBD. It has an ON-OFF function for disabling the internal receiver (in Level I programming). The internal receiver does not support FloR or Flo coding.
Electrical connections for external devices ( photocells, warning beacon etc.) have been simplified in the NICE Robus RBS range using BlueBUS, which allows multiple devices to be connected to a shared terminal using a single two-core cable (with no need to observe polarity). Conventional relay photocells can also be connected to the control unit.. The control unit MCU1R30 also has an OSE input (Optoelectronic Safety Edge), max. 15 mA.
Automatic drive operation depends on the availability of mains power. In the event of a power outage, the motor can be released using the release key. You can also purchase a NICE PSS124 backup battery, which keeps the drive operating during a power outage. The older backup power supply NICE PS124 is compatible only when used with the adapter CABLA11.
The drive has two LEDs: green indicates movement, while red indicates active photocells, unusual conditions and faults. The limit switch is inductive.. The drive can also be controlled and its functions configured using the mobile My Nice Pro app (Android/iOS).
Choosing a drive – is the NICE Robus RBS800 right for my gate?
Every gate has its own size (i.e. lever arm) and weight (i.e. the force exerted by the lever arm), and every drive has its limits. The NICE Robus RBS800 drive can be used with gates of the following leaf lengths and weights:
| Cycles per hour Consecutive cycles |
Gate leaf weight | ||
|---|---|---|---|
| up to 600 kg | up to 800 kg | ||
| Gate leaf length | up to 4 m | 40 | 35 |
| from 8 m | 20 | 20 | |
In principle, the gate leaf length determines the maximum number of cycles per hour and the maximum number of consecutive cycles, i.e. it indicates how long the drive can operate. Greater weight reduces these figures proportionally because of the increased strain, and also determines the maximum permitted speed for that load. The drive is equipped with a thermal protection device that measures the temperature of the motor and its surroundings and reduces the number of possible cycles accordingly.
The stated values apply when the manufacturer's conditions are met (weather conditions, temperatures, rigidity and smooth movement of the gate). In practice, we recommend keeping the total load to approximately 80% of these parameters.
NICE Robus RBS800 drive limits
The stated values are recommended by NICE. Based on our experience, we recommend allowing for a margin and sizing the drive for approximately 80% of the stated values:
| Robus RBS800 | Maximum | Recommended |
|---|---|---|
| Gate leaf length | 8 m | 6.4 m |
| Gate leaf weight | 800 kg | 640 kg |
Operating the drive at its maximum capacity reduces its service life – below is an estimated service-life calculation based on stress factors.
NICE Robus RBS800 drive service life
In the table, add the stress indices for gate leaf weight and length, then add the indices for other factors (if applicable). Then use the graph to determine the drive's service life in cycles.
Example: A gate with a clear opening of 4.5 m and a weight of up to 200 kg: length index ~30 + weight index 10 + low-temperature index 10 ⇒ total 40. The graph indicates ~120,000 cycles, which at 10 operations per day is approximately 32 years.
Installing the NICE Robus RBS800 drive
The installation method of the drive is different for a track-mounted sliding gate and a cantilever sliding gate . For a track-mounted gate the drive is generally installed at ground level, while for a cantilever gate the drive must be raised (using Ø8 threaded rods, a custom bracket, a concrete plinth, etc.). The rack height is critical so it meshes correctly with the drive pinion (see “The rack and its end stop”).
Wiring
A typical (optional) drive and accessory wiring setup looks as follows:
List of accessories
- A – Nice Robus RBS drive
- B – Photocells
- C – Photocell posts
- D – Key switch
- E – Flashing beacon with built-in antenna
- F – Rack
- G – Fixed safety edge 1
- H – Moving safety edge 1
- I – Opening end stop
- J – Fixed safety edge 2
- K – Moving safety edge 2
- L – Closing end stop
- M – Remote control
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| Power supply | 3 × 1.5 mm² |
30 m For longer distances, use 3 × 2.5 mm² + grounding. |
| Flashing beacon with antenna |
2 × 0.5 mm² 1 × RG58 coaxial cable |
20 m 10 m (recommended < 5 m) |
| Photocells | 2 × 0.5 mm² |
30 m; over 30 m, use 2 × 1 mm²
If the BlueBUS cable is > 30 m (max. 50 m), use 2 × 1 mm². |
| Key switch | 2 cables, each 2 × 0.5 mm² |
50 m
Can be replaced with a single 4 × 0.5 mm² cable. |
| Safety edges – fixed | 2 × 0.5 mm² |
30 m
For multiple fixed safety edges, see the manual – “Adding or removing devices / STOP input”. |
| Safety edges – moving | 2 × 0.5 mm² |
50 m
For multiple fixed safety edges, see the manual – “Adding or removing devices / STOP input”. |
Installation
Correct positioning height of the drive is one of the requirements for proper operation. More in the article “What height should the drive be installed at?”.
The rack and its end stop
Operating principle: the pinion's rotary torque is converted into linear movement via the rack-and-pinion drive on the rack. The most common types:
| Nylon rack (sometimes with a steel reinforcement) – fixed with self-tapping screws through the mounting tabs; ideal for lighter/shorter gates, with quieter operation (nylon vs. steel pinion). | |
| Steel rack – attached by welding threaded brackets in place and then screwing the rack on; for longer/heavier gates, with slightly noisier operation (steel vs. steel). |
It is essential that the drive pinion module is compatible with the module of the rack. The NICE Robus RBS800 drive has a tooth module of 4.
The drive unit detects the open and closed end positions using limit stops mounted on the rack.
How to install the limit stops on the rack:
1. Align the drive unit and gate. The gate and drive unit must be level.
2. Leave a 1–2 mm gap between the rack and pinion so the gate’s weight is not transferred to the motor.
3. Tighten the drive unit anchor bolts to prevent it from shifting when engaged.
4. Move the gate to the open position and adjust the stops so they activate the switch at the end position.
5. Move the gate to the closed position and adjust the stops so they activate the switch at the end position.
Wiring the NICE Robus RBS800 drive unit
Before connecting, disconnecting or changing the wiring of the drive unit (to the mains or auxiliary devices), remember to disconnect the power supply – switch off the circuit breakers, remove the power fuse or disconnect the backup battery.
MAINS WIRING
|
For basic operation, you need to connect a power supply to the drive unit . |
| The wiring is simple: | |
| L – live (brown) | |
| I – earth/PE (green) | |
| N – neutral (blue) |
AUXILIARY DEVICE WIRING
NICE MCU1R30 control unit for the NICE Robus RBS800 drive unit supports the following inputs and outputs:
| Input/output | Description |
|---|---|
| FLASH (warning light) |
24 V output for a warning light, e.g. Nice ELDC. |
| OGI (indicator) |
Output for an indicator (24 V). Behaviour configurable in level II programming, item L4 – Output indicator. |
| PHOTO (photoelectric cells) |
Input for photoelectric cells. |
| STEP-BY-STEP (SbS, P.P., step-by-step control) |
Input for devices that control the gate’s movement step by step. NO (normally open) contacts can be connected. |
| 24 V (+) | Power supply for external devices (e.g. contactless card reader): 24 V DC, −30% to +50%, max. current 100 mA. |
| GND (ground) |
Ground for external devices powered from the 24 V terminal. |
| STOP (stop) |
Input for devices that stop the gate’s movement. Possible wiring configurations:
|
| OSE (optical safety edge) |
Interface for an OSE (Optical Safety Edge) sensor, 12 V. |
| BLUEBUS | Input for connecting compatible devices in parallel using BlueBUS technology (the two-wire cable provides both power and communication). |
| AERIAL (antenna) |
Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. Nice ELDC, or an external NICE Aerial ABF. |
Drive unit fuses
The drive unit contains two fuses:
| Designation | Protected circuit | Type |
|---|---|---|
| F1 | control unit | T 2A 250 V |
| F2 | power supply | T 1.6A 250 V |
|
||
Standard wiring diagram
Drive unit photoelectric cells
User-friendly BlueBUS technology allows you to power and control up to 7 pairs of photoelectric cells using a two-wire cable.
Connecting multiple pairs of NICE EPMB photoelectric cells to a NICE BlueBUS data network
Position the photoelectric cells around the gate according to the example configurations for complete wiring, and set the jumpers according to the jumper table for the photoelectric cells NICE EPMB. To prevent interference between pairs installed close together, observe the orientation of the transmitters TX and receivers RX as shown in the example configurations. Wire the photoelectric cells in parallel as shown (polarity does not matter):
If you need the photoelectric cells to function as gate openers (see FA1 and FA2 in the example configurations), i.e. when a vehicle enters between their optical axes and triggers opening, interrupt connection A on the transmitter TX and receiver RX – see figure:
Example of a photocell wiring configuration
NICE EPMB photocell jumper table
![]() |
Connecting multiple pairs of photocells to the system BlueBUS is configured by setting different jumper combinations. Each connected pair must have a unique combination; two pairs in the same BlueBUS data network must not have the same setting. Set the jumper identically on both the TX transmitter and RX receiver in each pair. Keep unused jumpers for future use. |
| Photocell pair designation | Jumper – jumper combination |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
| FOTO 3 | ![]() |
| FA1 (Interrupt connection A on both TX and RX) |
![]() |
| FA2 (Interrupt connection A on both TX and RX) |
![]() |
If you need to replace a photocell, set the same jumper on the replacement as on the original; there is no need to repeat the device recognition procedure.
Radio receiver for gate operators
The NICE Robus RBS800 operator has a built-in radio receiver in the control unit NICE MCU1R30. MCU1R30 also has an SM connector (under the plastic cover) for connecting an external radio receiver NICE OXIBD (or the older NICE OXI). The SM connector makes it easy to upgrade from an older Robus RB operator to a Robus RBS operator while keeping the paired remote controls.
Selecting the gate travel direction
The direction setting must match the position of the operator relative to the gate leaf. Look at the gate from the side where the operator is installed.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
| The switch is on the rear right-hand side of the MCU1R30 control unit. |
|
Recognizing connected operator devices
After connecting, disconnecting or changing the wiring of any devices on the BlueBUS and STOP inputs, run the accessory recognition procedure.. The operator indicates this by flashing LEDs L1 and L2.
![]() |
|
Recognizing the gate-leaf length
To calculate the acceleration/deceleration travel and partial opening correctly, the operator must measure the length of the gate leaf. During the procedure, it moves the gate from one end stop to the other and measures the length using the switch.
Programming the operator
The Robus RBS operator offers several programmable functions: functions can be enabled or disabled by Level I programming, or their default parameters can be adjusted by Level II programming.
MCU1R30 control unit has three buttons for operating and programming the operator:
Programming – Level I
At Level I, programming enables or disables the selected function.. When a function is enabled, the corresponding LED on the control unit lights up. All functions are disabled by default.
Entering Level I programming. Press and hold the “Stop/Set” button for approximately 5 seconds, until the LED starts flashing L1. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each action; otherwise, the drive will exit the mode. When the flashing LED is beside the function you want to change, press “Stop/Set” to make it flash faster (function enabled) or slower (function disabled), then let the drive exit the mode on its own within 20 seconds. If everything worked correctly, the corresponding LED will remain lit.
List of functions that can be enabled or disabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After the set time (“Level II programming – Pause duration”), the gate closes automatically after opening. If this function is disabled, the gate responds only to a command (e.g. from a remote control or similar). |
| L2 | Close after photocells are interrupted | Once the photocells are clear (the vehicle has passed), closing starts after 5 seconds. Behavior depends on L1:
|
| L3 | Always close | After a power failure, the gate either remains in its original position (disabled) or closes automatically (enabled). |
| L4 | Standby mode | Reduces power consumption to a minimum (useful with PSS124). One minute after the last movement, BlueBUS (and connected devices) and all LEDs except the BlueBUS LED switch off (the BlueBUS LED flashes slowly). When a command is received, the control unit wakes up/restarts first and only then carries out the command. |
| L5 | Soft start | Disables the soft start—the motor immediately runs at full power (useful when friction is high or in snow/ice). Reduces the drive's service life. |
| L6 | Pre-flashing | Before the gate starts moving, the warning light flashes for 3 seconds before the movement begins. |
| L7 | Disable the built-in radio control | Disables the integrated radio receiver in the control unit. Enable this if you are using an external plug-in receiver such as an OXI. When this function is disabled, the internal receiver is active. |
| L8 | “Slave” mode – subordinate unit | When activated, the drive becomes the “Slave”. Allows two motors on opposing gate leaves to be synchronized (Master/Slave). For details, see the Robus RBS manual, section “Slave mode”. |
Programming – Level II.
Level II is used to set function values (unlike Level I).
Entering Level II programming. Press and hold the “Stop/Set” button for approximately 5 seconds, until LED L1 starts flashing. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each action; otherwise, the drive will exit the mode. When the LED is beside the function whose parameter you want to adjust, press and hold “Stop/Set” to enter the settings. The lit LED (while you continue holding “Stop/Set”) indicates the current value. Change the value using “Open” (up) or “Close” (down), then release “Stop/Set” and wait for the drive to exit the mode within 20 seconds. To verify the setting, repeat the procedure without changing the value.
List of adjustable functions:
| Input LED — Name and description | Setting LED — Value |
|---|---|
| L1 — Pause duration If “Automatic closing” is enabled in Level I, this sets the interval between opening and automatic closing. |
L1 — 5 s L2 — 15 s L3 — 30 s L4 — 45 s L5 — 60 s L6 — 80 s L7 — 120 s L8 — 180 s |
| L2 — Step-by-step mode Sets the movement sequence for repeated commands (remote-control button or STEP-BY-STEP/P.P./step-by-step input). Note: with L4, L5, L7 and L8, the behavior of the “Open” and “Close” commands changes. |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium L5 — Condominium after two “Stop” commands L6 — Step-by-step after two “partial opening” commands L7 — Hold-to-run L8 — “Semi-automatic” opening; hold-to-run closing |
| L3 — Motor speed Speed during normal operation (not during acceleration or deceleration). „L6 — Extremely fast” = 100% of 0.34 m/s, etc. |
L1 — Very slow (30%) L2 — Slow (44%) L3 — Medium (58%) L4 — Fast (72%) L5 — Very fast (86%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
| L4 — OGI output indicator Setting the OGI output function (supplies 24 V when activated, −30%/+50%, max. 10 W). |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
| L5 — Motor force Adjusts the force control to the weight of the automation system. The system also takes the ambient temperature into account and increases the force in cold weather. |
L1 — Extremely light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Medium-heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Extremely heavy gate |
| L6 — Partial opening Passage width when partially open. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.4 m L8 — 4.0 m |
| L7 — Maintenance alert Number of operating cycles after which the drive signals that maintenance is required. |
L1 — 1,000× L2 — 2,000× L3 — 4,000× L4 — 7,000× L5 — 10,000× L6 — 15,000× L7 — 17,000× L8 — 20,000× |
| L8 — Fault log Check the fault type for the last 8 operating cycles (see “Fault history” in the manual). |
L1 — Result of the 1st operating cycle L2 — Result of the 2nd operating cycle L3 — Result of the 3rd operating cycle L4 — Result of the 4th operating cycle L5 — Result of the 5th operating cycle L6 — Result of the 6th operating cycle L7 — Result of the 7th operating cycle L8 — Result of the 8th operating cycle |
Automating two opposing sliding gates with two NICE Robus RB800 operators (Master-Slave mode)
If you need to automate two sliding gates facing each other, the Robus operators support slave mode (“Master-Slave”). One operator acts as the master (Master) and sends commands to the other, slave (Slave). All Robus operators are set as master at the factory, so enable function L8 (Slave unit). The connection between Master ↔ Slave is made via BlueBUS.
Restrictions when connecting master and slave units
- The gate cannot be opened using the slave unit.
- All devices (e.g. photocells, external receiver etc.) must be connected to the master unit. Only the flashing light and devices connected to the inputs STOP, SBS (STEP-BY-STEP / Step-by-step) and the output indicator OGI; the inputs OPEN/CLOSE are ignored.
- If you use a backup battery (NICE PSS124), each operator must have its own.
- All programmed functions are ignored on the slave unit, except those listed below.
| Level I programming | Level II programming |
|---|---|
| L4 — Standby mode | L3 — Motor speed |
| L5 — Soft start | L4 — Output indicator |
| L8 — Slave unit | L5 — Motor force |
| L8 — Error log |
Procedure for installing two Robus operators in slave mode
- Install both gate leaves and both operators. Decide which one will be the Master (N) and which one will be the Slave (P). In Master-Slave mode, only the slave gate leaf can be fully opened.
- (P) Select the opening direction (direction switch on the control unit).
- (P) On the Slave run the device and gate-leaf length learning procedures (“Device learning”, “Gate-leaf length learning”). If the direction is reversed, repeat step 1.
- (P) On the Slave enable the “Master-Slave mode” function (Level I, L8).
- (P+N) Connect the two automation systems according to the diagram.

- (N) Select the opening direction on the Master.
- (N) On Master perform the device and leaf length learning procedure. The Slave will also move while the length is being learned. For the opposite direction, repeat step 6.
Connecting additional external devices
To the control unit
On the MCU1R30 control unit there are 24 V DC (+) and GND (−) for powering external devices, as well as terminals OGI, BlueBUS and Flash. In Master-Slave mode, connect devices to the master drive (for exceptions for "Slave" see the manual – "Master-Slave Mode").
MCU1R30 also allows you to connect an expansion board, which provides additional inputs and outputs.
Expanding the control unit with additional inputs/outputs
The control unit can, in addition to the terminals provided, connect an expansion board.. This allows the MCU1R30 unit to be expanded with additional inputs and outputs, enabling more devices to be connected. The number and type of inputs and outputs depend on the type of expansion board. For MCU1R30 There are currently 3 types of expansion boards available:
MLAE21 - 2x 24V inputs (factory settings: Open, Close), 1x 24V output (factory setting: OGI)
MLAE22 - 2x 24V inputs (factory settings: Open, Close), 1x 24V output (factory setting: OGI), 1x 230V output (factory setting: Lighting)
MLAE44 - 4x 24V inputs (factory settings: Open, Close, Partial Open, Photo), 4x 24V outputs (factory settings: OGI, Gate Closed, Radio Output 4, Phototest)
Procedure for connecting the expansion board:
Adding or removing expansion boards must always be carried out with the power disconnected (by removing fuse F2 and, if connected, the backup battery).
Procedure for learning additional devices.
After adding or removing devices, the automation must be tested again as described in the “Testing” section (see the manual, step 6.1, on page 24).
Special drive functions
Gate held open
If a command to the STEP-BY-STEP input (P.P., SbS, Step-by-step) lasts longer than 2 seconds, the control unit will keep the gate open for as long as the command is active. Suitable for use with a timer.
Forced operation
If a safety device fails or an obstacle blocks, for example, the photocells and the gate does not move for safety reasons, activate “Hold-to-run” mode—continuously (Level II, L2 = L7) or temporarily:
- Send a command (e.g. remote control or key switch).
- If there is a problem, the gate will not move and the flashing light will probably indicate an error.
- Send the command again within 3 seconds of the previous command and hold it.
- The gate moves while the button is held; it stops when the button is released.
Maintenance alert
In Level II programming, at item L7 – Maintenance alert you can set the number of cycles after which the drive signals that maintenance (inspection) is required. The drive signals this using the flashing light (or, if Level II programming item L4 – Output indicator is set to level L7 – Maintenance), as follows:
| Number of cycles | Flashing light signal | OGI output indicator signal |
|---|---|---|
| less than 80% of the limit | Normal operation; flashing at half-second intervals. | “Lights up” for 2 seconds after opening begins. |
| 80–100% of the limit | Lights for 2 s after the movement starts, then continues normally. | Flashes during movement. |
| over 100% of the limit | Lights for 2 s after the movement starts, then operates normally; lights again for 2 s after the movement ends. | Flashes continuously. |
These settings can also be configured using the mobile app My Nice Pro.
Troubleshooting the drive
If anything is unclear or you have another issue, feel free to contact our technical support for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
| Problem | Possible solution |
|---|---|
| The gate does not respond to the remote control, and the LED on the remote does not light up. | Check whether the batteries in the drive remote control are working; if not, replace them (see the instructions in the manual for the specific remote control). |
| The gate does not respond to the remote control, but the LED on the remote lights up. | Check whether the remote control has been stored in the receiver's memory correctly; if necessary, store it again. |
| The gate does not move and the BlueBUS LED does not flash. | Check that the drive is receiving a 230 V power supply. If it is, test both fuses and replace them, if necessary, with new ones of the same rating. |
| The gate does not move and the warning light does not flash. | Check whether the drive has registered the command: – for a command from the remote control, the BlueBUS LED should flash twice quickly; – for a command via the STEP-BY-STEP (SbS) input, the corresponding STEP-BY-STEP LED should light up. |
| The gate does not move and the warning light flashes several times. | Count the flashes and see the section “Diagnostics Using Warning-Light Flashes” below. |
| The gate starts moving, but then stops and reverses. | The motor force is probably set too low. Check for obstructions and, if necessary, increase the force or enable the “Soft start“. |
| The gate starts moving, but the warning light does not work. | Check whether voltage (approx. 10–30 V DC) is present at the FLASH terminal during movement. If voltage is present, the problem is with the warning light – try replacing it. If there is no voltage, the FLASH output may have been overloaded – check the wiring for a short circuit. |
| The gate starts moving, but the OGI output does not work. | Check which function is assigned to the OGI output; if it is supposed to flash, check for 24 V DC. If voltage is present, the bulb is faulty – replace it. If there is no voltage, the OGI output may have been overloaded – check the wiring for a short circuit. |
Diagnostics Using Warning-Light Flashes
While the gate is moving, the warning light flashes regularly once per second. If a problem occurs, it signals an error with two faster series of flashes in succession.
| Flash sequence | Error | Solution |
|---|---|---|
| 1 flash, 1 s pause, 1 flash | BlueBUS error | The devices connected to the BlueBUS input do not match those detected during the setup phase. Repeat the setup phase; if that does not help, use the process of elimination to identify the faulty device, then replace it, repair it or submit a warranty claim. |
| 2 flashes, 1 s pause, 2 flashes | Photocell activation | The photocells are being activated (normal if the beam is interrupted while closing). If the beam was not interrupted, the photocells may be dirty, affected by glare or faulty. |
| 3 flashes, 1 s pause, 3 flashes | Motor force limiter activated | The gate is detecting increased friction – check and adjust the gate (test its manual movement). Increasing the force or enabling “Soft start“. A bottom stop that is set too high may also be causing the problem.. |
| 4 flashes, 1 s pause, 4 flashes | STOP input activated | A command was received at the STOP input. If this was not expected, check the connected devices. |
| 5 flashes, 1 s pause, 5 flashes | Internal control unit error | Wait at least 30 seconds, then repeat the command. If the error persists, try a reset.. The control unit will probably need to be repaired or replaced. |
| 6 flashes, 1 s pause, 6 flashes | Hourly movement limit reached | Wait a few minutes for the cycle limiter to drop below its maximum. |
| 7 flashes, 1 s pause, 7 flashes | Internal electronic circuit error | Disconnect the drive from the power supply for a few seconds, reconnect it and try the command again. If the problem persists, try a reset.. If that does not help, the control unit will probably need to be repaired or replaced. |
| 8 flashes, 1 s pause, 8 flashes | Continuous command active | If a command is being sent to the drive continuously, check the devices connected to the OPEN input. If a timer is connected, it is probably sending this continuous command. |
Diagnostics Using LED Flashes
Diagnostics can be performed by monitoring several sets of LEDs. Two sets are locatedon the control unit, and the third is the status light directly on the drive.
On the drive...
The status light is located on the front of the cover of Nice RBS drives..
The red and green LEDs indicate normal operation and provide basic gate diagnostics, as shown in the table below. If the drive detects an anomaly/error, it signals it using the warning light.
| Status light with positions learned | |
|---|---|
| Green light | |
| on | Indicates the start of each gate movement, if there are no anomalies/errors in the system and turns off when the movement ends. |
| off | Normal operation |
| Red light | |
| on | Indicates the start of each gate movement, if the set number of movements before maintenance has been exceeded; and turns off when the movement ends. |
| off | Normal operation |
| Warning light | The control unit has detected an anomaly. See the table “Diagnostics using warning-light flashes”. |
| Status light with positions NOT learned | |
|---|---|
| Green light | |
| on | The light comes on when the opening limit switch is reached. |
| off | Normal operation |
| Red light | |
| on | The light comes on when the closing limit switch is reached. |
| off | Normal operation |
| Warning light | The control unit has detected an anomaly. See the table “Diagnostics using warning-light flashes”. |
On the MCU1/MCU1R30 control unit...
MCU1R30 control unit of the NICE Robus RBS800 drive
MCU1 control-unit LEDs
| Horizontal LEDs: BLUEBUS, STOP, SbS, FOTO: | Signal | Status |
|---|---|---|
| Solution | ||
| BlueBUS LED | off | anomaly/error |
| Check the mains connection. If it is OK, check fuses F1 and F2 and replace them, if necessary, with new fuses of the same rating. | on |
serious fault Try disconnectingthe control unit, and, if necessary, all inputs. If this does not help, reset the control unit. |
| If the fault persists, the control unit will probably need to be replaced. | 2 green flashes at one-second intervals | everything is OK |
| Normal control-unit operation. | 2 quick green flashes |
input status changed Normal operation – the status of the STEP-BY-STEP, STOP, OPEN or CLOSE input changed, or thephotocells , or the drive received a command from the. |
| remote control | a series of red flashes separated by a one-second pause | various The number of flashes in the series corresponds to the fault diagnosis indicated by the warning light. See. |
| “Diagnostics using warning-light flashes” | a series of rapid and slow red flashes | short circuit at the BlueBUS terminal Disconnect the terminal and check the BlueBUS connections to find the cause of the short circuit. |
| Once the short circuit has been eliminated, reconnect the terminal. The LED will start flashing again after ten seconds. | ||
| STOP LED | off | STOP input activated |
| Check the devices connected to the STOP input. | on | STOP input did not respond |
| The STOP input is active. | ||
| STEP-BY-STEP LED (also labelled SbS, P.P. or Krokovanie) | off |
everything is OK |
| The STEP-BY-STEP input is inactive. | on | STEP-BY-STEP input activated |
| Normal control-unit operation if a device connected to the STEP-BY-STEP input has been activated. | ||
| FOTO LED | off | FOTO input activated |
|
The FOTO input has been triggered. |
on | Everything is OK |
Normal control-unit operation if the safety device has not been triggered.
| Vertical LEDs L1–L8: | Signal |
|---|---|
| Solution | |
| LED 1 | off During normal operation, indicates that the “Automatic closing” |
| is disabled. | on During normal operation, indicates that the “Automatic closing” |
| function is enabled. |
flashing
|
| - If it flashes at the same time as L2, this means that the connected devices need to be evaluated. | |
| LED 2 | off During normal operation, indicates that the “Close” |
| function after interruption of the photocells is disabled. | on During normal operation, indicates that the “Close” |
| function after interruption of the photocells is enabled. |
flashing
|
| - If it flashes at the same time as L1, this means that the connected devices need to be evaluated. | |
| LED 3 | During normal operation, indicates that the "Always close" function is disabled. |
| on | During normal operation, indicates that the "Always close" function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 4 | |
| off | During normal operation, indicates that the "Standby mode" function is disabled. |
| on |
During normal operation, indicates that the "Standby mode" function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 5 | |
| off | During normal operation, indicates that the "Soft start" function is disabled. |
| on | During normal operation, indicates that the "Soft start" function is enabled. |
| flashing | Functions are being programmed. |
| LED 6 | |
| off | During normal operation, indicates that the "Pre-flashing" function is disabled. |
| on | During normal operation, indicates that the "Pre-flashing" function is enabled. |
| flashing | Functions are being programmed. |
| LED 7 | |
| off | During normal operation, indicates that the "Internal radio receiver" function is disabled. |
| on | During normal operation, indicates that the "Internal radio receiver" function is enabled. |
| flashing | The function is being programmed. |
| LED 8 | |
| off | During normal operation, indicates that Robus is configured as a "Master unit" (also called Master). |
| on | During normal operation, indicates that Robus is configured as a "Slave unit" (also called Slave). |
| flashing | The function is being programmed. |
Installing a backup battery on the NICE Robus RBS800 operator
The backup NICE PSS124 battery is not included as standard with the operator, but can be ordered separately. In the event of a power failure, it will power the gate operator. The battery is continuously charged from the mains. Connect the battery to the control unit only after completing all installation and programming steps.
Manually releasing the NICE Robus RBS800 operator
In the event of a power failure or fault, you will not be able to operate the gate using the remote control. Therefore, you can release the operator using the release key and move the gate manually.
1. Open the locking hook (A) with the supplied key and pull out the release lever. You can now move the gate manually.
2. To lock the gate, close the locking hook, turn the key anticlockwise and remove it.
Technical specifications of the NICE Robus RBS800 operator
| Model | NICE Robus RBS800 |
|---|---|
| Description | Electromechanical gear motor for automatic operation of sliding gates in private residential settings. Supplied with NICE MCU1R30 control unit with an integrated radio receiver. |
| Pinion |
|
| Torque [Force] |
22.5 Nm [750 N] – force required to start the gate leaf moving |
| Rated torque [Rated force] |
12 Nm [400 N] – force required to keep the gate leaf moving |
| Speed | 0.30 m/s |
| Cycle limit | Gate leaf length up to 4 m, 35 cycles/hour. Up to 8 m, 20 cycles/hour. |
| Duty limit | 7 minutes (the control unit limits the time according to the conditions – see drive selection) |
| Service life | Approximately 20,000–250,000 cycles, depending on the weight and length of the gate leaf and the drive settings. |
| Power supply | 230 V (+10% / −15%) 50/60 Hz |
| Power consumption [Load] |
230 W [1.1 A] |
| Insulation class | 1 – must be earthed |
| Backup power supply | An NICE PSS124 backup battery can be purchased separately and installed. (When using the adapter CABLA11 it is also possible to use the older model PS124.) |
| Protection rating | IP44 |
| Dimensions | 340 x 220 x 303 mm |
| Control unit | MCU1R30 |
360° view of the Nice Robus RBS800 drive