NICE ROBUS RBS600 HS - high-speed drive for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€601.78 including VAT
| Weight |
|---|
| 11 kg |
Description of NICE ROBUS RBS600 HS - high-speed drive for sliding gates (A)
The NICE Robus Hi-Speed RBS600 HS gate operator is designed for fast operation of sliding gates up to 600 kg and a passage width of up to 8 m. It has a magnetic stop switch. The operator is non-reversible. Operator programming. Installation manual.
Built-in control unit witha built-in radio receiver, and with a built-in Wi-Fi receiver for control via a mobile app.
Key features:
- Fast, energy-efficient operation – powerful motor with 90% lower energy consumption in standby mode. Opens a gate with a 4 m passage width in just 10 seconds.
- Easy installation and programming – built-in radio receiver, adjustable mounting base and convenient control via the MyNice / MyNice Pro app, thanks to the built-in Wi-Fi receiver.
- Smart, safe operation – automatic learning of operating times, speed and force adjustment, and the Eye Check diagnostic system for monitoring the status of the drive and accessories.
- Flexible connectivity – BlueBUS technology enables simple two-wire connection of up to 7 pairs of safety and control devices. Can be expanded with additional inputs and outputs using optional modules.
- Remote control – built-in Wi-Fi connectivity or a BIDI-ZWAVE module for integration with smart home systems.
- Reliable, durable construction – mechanically robust design, a secure release lever and an inductive limit switch for compact installation with a shorter rack.
- Compatible with older models – easy replacement of Nice Rox, Road and Robus systems.
- Photocells can be installed directly under the drive cover. To use this optional feature, you need to purchase the RBSKITSAFE1 kit, which is not included. It also supports an optional white status light, sold separately as the ELMM.
Compatible remote controls:
The drive has a built-in receiver and is compatible with NICE series remote controls MYGO, ONE and INTI. The internal receiver does not support FloR or Flo coding. However, the control unit also has an SM connector for connecting a plug-in receiver, which may be useful if you have replaced an older drive with a new RBS and own older-style remote controls.
Information for owners of older NICE FLOR remote controls:
If you already own older NICE FLOR remote controls (models FLO2R-S, FLO2RE, FLO4R-S, FLO4RE), you can continue to use them with the new NICE RBS. However, you will need to purchase a plug-in OXIBD receiver or one of the external receivers, such as the NICE OX2.
Extra-long range for remote controls:
The NICE RBS drive has a slot for an internal receiver, allowing you to install the NICE OXILR receiver with LoRa. You can also connect the NICE OXIFM receiver for additional features.
Information for owners of older NICE FLO and NICE SMILO remote controls:
If you use NICE remote controls at home with FLO or SMILO, these can also be used with the NICE RBS. However, you must purchase the internal OXIBDreceiver, which supports fixed-code signals (FLO, SMILO). In this case, the receiver will accept only these older remote-control types; newer models cannot be paired at the same time.
This product – the NICE Robus Hi-Speed RBS600HS sliding gate drive (drive only; our code NICE-RBS600HS-A) – includes:
- NICE Robus Hi-Speed RBS600HS electromechanical drive, rated for gates weighing up to 600 kg and with a maximum leaf length of 8 m, with an integrated (but removable) MCU4 control unit, built-in Wi-Fi receiver, radio receiver and an “SM” connector for a plug-in receiver.
- 2 x release keys for manual operation of the drive (required in the event of a power failure).
- Drive mounting components: anchors, mounting plate and magnetic stops for the inductive limit switch.
- Installation manual
Accessories compatible with the Nice Robus Hi-Speed RBS600HS drive
We recommend purchasing compatible optional accessories for the drive or choosing one of our pre-assembled drive kits at a discounted price.
| What | Why | Type |
|---|---|---|
| Warning light | Flashes to indicate gate movement – ideal for exits with limited visibility. Also includes an antenna for increased remote-control range. | |
| Photocells | Detect obstacles as the gate closes and stop its movement, preventing it from hitting cars or people. |
|
| Remote control | For operating the gate remotely. | |
| Receiver |
For remote gate control. The RBS operator has an integrated radio receiver, but also allows an external receiver to be connected. This makes it easy to switch from an older RB operator to a newer RBS without pairing the remote controls again. |
|
| Programming devices |
|
|
| Antenna | For improved remote-control range. |
|
| Keypad | If you forget your remote control, or have many vehicles or users and don’t want to give everyone a remote. | |
| Key switch | Control the gate with a key using a switch wired to the operator. | |
| Card readers | Operate the gate by presenting a card or key fob to the reader. |
|
| Rack | Essential for automation—the operator cannot move the gate without a rack. | |
| Backup power supply | Keeps the gate operating during a power outage. |
Manuals and documents for download
Nice Robus Hi-Speed RBS600HS operator manual – PDF
Instructions for pairing remotes with a Nice operator – link
NICE Robus Hi-Speed RBS600HS at a glance
NICE Robus RBS is a family non-reversible electromechanical geared operators for sliding gates. The high-speed operator model Robus RBS Hi-speed is supplied with a built-in (but removable) NICE MCU4 control unit with an integrated radio receiver and an SM connector for plug-in radio receivers of the OXI type, such as NICE OXIBD. It features an ON-OFF function for disabling the internal receiver (in Level I programming). The internal receiver does not support FloR or Flo coding.
Electrical connections for external devices ( photocells, warning light etc.) have been simplified in the NICE Robus RBS range by BlueBUS, which allows multiple devices to be connected to a shared connector using a single two-core cable (with no need to observe polarity). You can also connect conventional relay photocells.
Built-in Wi-Fi receiver lets you control the automation system using the My Nice Pro mobile app. Together with the programming device Nice Proview it lets you configure and program the operator’s functions remotely, directly from your smartphone. The app is available for Android and iOS.
Compared with MCU1 the control unit MCU4 is more modern and faster and offers more options and accessories for automation. The MCU4 also features an OSE input (Optoelectronic Safety Edge, max. 15 mA) and NICE MLAE22 port expansion board. The board offers 2 additional outputs (one of which is 230V) and 2 inputs for connecting accessories to the control unit.
User-friendly BlueBUS technology makes it easy to power and control up to 7 pairs of photocells using a two-core cable.
Photocells can be integrated directly beneath the cover of the Robus RBS Hi-speed (RBS600HS) drive, giving it an aesthetic, clean appearance for the gate. The installation kit RBSKITSAFE1 is not included in the standard package, however, and must be purchased separately. In addition, the RBS600HS can be upgraded with a so-called white status light, purchased separately as the ELMM.
module. Automatic operation of the drive depends on the power supply. In the event of a power outage, the motor can be released using the release key. You can purchase a NICE PSS124 backup battery, which allows the system to operate during a power outage. The older backup power supply model, NICE PS124 is compatible only when used with the CABLA11.
The “Slave Unit” function (master-slave mode) enables synchronised control of two motors, allowing a pair of opposing sliding gates to be automated. It is also compatible with the older Robus RB600, model, but only from the version with the RBA3R10 control unit. The older RBA3/c is not compatible with the RBS..
The integrated “Eye Check” system provides visual feedback via an LED light (red/green). Green indicates movement; red indicates active photocells, abnormal conditions and errors.
It features a gear module 4, compatible with the rack available in our range. The limit switch is inductive..
The high-speed Nice Robus Hi-speed RBS600HS drive features obstacle detection and a temperature sensor that adjusts the drive's pulling force to weather conditions and is protected by a thermal fuse..
The drive's durable construction, with an ingress protection rating of IP44, ensures a long service life. The Robus Hi-Speed RBS600HS is compatible with Nice accessories.
Choosing a drive – is the NICE Robus Hi-Speed RBS600HS suitable for my gate?
Every gate has its own size (i.e. lever arm) and weight (i.e. the force of gravity acting on the lever arm), and every drive has its limits.. The NICE Robus Hi-Speed RBS600HS drive is suitable for the following gate leaf lengths and gate weights:
|
Cycles per hour / consecutive cycles |
Gate leaf weight | ||
|---|---|---|---|
| up to 400 kg | up to 600 kg | ||
| Gate leaf length | up to 4 m | 35 | 40 |
| up to 8 m | 20 | 20 | |
In principle, the gate leaf length determines the maximum number of cycles per hour and the maximum number of consecutive cycles, i.e. it specifies how long the drive can operate. A heavier gate reduces these numbers proportionally because of the increased strain, and also determines the maximum permitted speed for a given load. The drive is equipped with a thermal fuse that measures the temperature of both the motor and its surroundings, reducing the number of possible cycles accordingly.
The stated values apply when the manufacturer's conditions are met (weather conditions, temperatures, rigidity and smooth gate movement). In practice, we recommend keeping the total load to approximately 80% of these parameters.
Limits of the NICE Robus Hi-Speed RBS600HS drive
The stated values are recommended by NICE. Based on our experience, we recommend allowing a margin of around 20% below the stated values:
| Robus RBS400HS | Maximum | Minimum |
|---|---|---|
| Gate leaf length | 8 m | 6 m |
| Gate leaf weight | 600 kg | 480 kg |
Operating the drive at its limit reduces its service life. Below is an indicative estimate of service life based on stress factors.
Service life of the NICE Robus Hi-Speed RBS600HS drive
In the table, add the stress indices for the gate leaf's weight and length, then add the indices for any other applicable factors. Then use the graph to estimate the drive's service life in cycles.
Example: A gate with a clear opening of 4.5 m and a weight of up to 200 kg: length index ~30 + weight index 10 + low-temperature index 10 ⇒ total 40. The graph indicates ~120,000 cycles, which at 10 operations per day is approximately 32 years.
Installing the NICE Robus Hi-Speed RBS600HS operator
The installation method of the operator is different for a track-mounted gate and freestanding sliding gate . For a track-mounted gate, the operator is generally installed at ground level; for a freestanding gate, the operator needs to be raised (using Ø8 threaded rods, a custom bracket, a raised concrete base, etc.). The key is to position the rack at the right height so that it meshes correctly with the operator's drive gear (see “Rack and its stop”).
Wiring
A typical (optional) wiring setup for the operator and accessories looks like this:
List of accessories
- A – Nice Robus Hi-Speed operator
- B – Photocells
- C – Posts with photocells
- D – Key switch
- E – Flashing light with built-in antenna
- F – Rack
- G – Fixed safety edge 1
- H – Moving safety edge 1
- I – Opening limit stop
- J – Fixed safety edge 2
- K – Moving safety edge 2
- L – Closing limit stop
- M – Remote control
Wiring list
| Purpose | Type | Max. length |
|---|---|---|
| Power supply | 3 × 1.5 mm² |
30 m For longer distances, use 3 × 2.5 mm² + grounding. |
| Flashing light with antenna |
2 × 0.5 mm² 1 × RG58 coaxial cable |
20 m 10 m (recommended < 5 m) |
| Photocells | 2 × 0.5 mm² |
30 m; for lengths over 30 m, use 2 × 1 mm²
AIf the BlueBUS cable is longer than 30 m (max. 50 m), use 2 × 1 mm². |
| Key switch | 2 cables, each 2 × 0.5 mm² |
50 m
Can be replaced with one 4 × 0.5 mm² cable. |
| Safety edges – fixed | 2 × 0.5 mm² |
30 m
For multiple fixed edges, see the manual – “Adding or removing devices / STOP input”. |
| Safety edges – moving | 2 × 0.5 mm² |
50 m
For multiple fixed edges, see the manual – “Adding or removing devices / STOP input”. |
Installation
The operator must be installed at the correct height to function properly. Read more in the article “What height should the operator be installed at?”.
Rack and its stop
How it works: the drive gear’s torque is converted into linear motion through the rack-and-pinion drive on the rack. The most common types are:
| Nylon rack (optionally reinforced with steel) – attached using self-tapping screws through the mounting holes; ideal for lighter/shorter gates, with quieter operation (nylon against a steel gear). | |
| Steel rack – attached by welding on threaded brackets and then fastening with screws; suitable for longer/heavier gates, with slightly louder operation (steel against steel). |
It is essential that the operator's gear module is compatible with the module of the rack. The NICE Robus Hi-Speed RBS600HS has a module of 4.
The operator detects the fully open and closed positions using limit stops mounted on the rack.
How to install the limit stops on the rack:
1. Level the operator and the gate. The gate and operator must be level.
2. Leave a 1–2 mm gap between the rack and the gear so the gate’s weight is not transferred to the motor.
3. Tighten the operator’s mounting bolts so it does not shift when engaged.
4. Move the gate to the open position and adjust the stops so they activate the switch at the end of travel.
5. Move the gate to the closed position and adjust the stops so they activate the switch at the end of travel.
Wiring the NICE Robus Hi-Speed RBS600HS operator
Before connecting, disconnecting or changing the wiring of the operator (to the mains or accessories), remember to disconnect the power supply – switch off the circuit breakers, remove the power fuse or disconnect the backup battery.
MAINS WIRING
|
For basic operation, the operator must be connected to the power supply. |
| The connection is simple: | |
| L – phase (brown) | |
| I – earth/PE (green) | |
| N – neutral (blue) |
CONNECTING AUXILIARY DEVICES
NICE MCU4 control unit for the NICE Robus Hi-Speed RBS600HS drive allows the following inputs and outputs:
| Input/output | Description |
|---|---|
| FLASH (warning light) |
24 V output for a warning light, e.g. Nice ELDC. |
| OGI (indicator) |
Output for an indicator (24 V). Behavior configurable in Level II programming, item L4 – Indicator output. |
| PHOTO (photocells) |
Input for photocells. |
| STEP-BY-STEP (SbS, P.P., step-by-step) |
Input for devices that step through the gate's movement. NO (normally open) contacts can be connected. |
| 24 V (+) | Power supply for external devices (e.g. contactless card reader): 24 V DC −30% ÷ +50%, max. current 100 mA. |
| GND (ground) |
Ground for external devices powered from the 24 V terminal. |
| STOP (stop) |
Input for devices that stop the gate's movement. Possible connections:
|
| OSE (optical safety edge) |
Interface for an OSE (Optical Safety Edge) sensor, 12 V. |
| BLUEBUS | Input for parallel connection of compatible devices using BlueBUS (the two-wire cable both powers and communicates). |
| AERIAL (antenna) |
Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. Nice ELDC, or an external NICE Aerial ABF. |
Drive fuses
There are two fuses in the drive:
| Designation | Protection for | Type |
|---|---|---|
| F1 | control unit | T 2A 250 V |
| F2 | power supply | T 1.6A 250 V |
|
||
Standard wiring diagram
Drive photocells
User-friendly BlueBUS technology allows you to power and control up to 7 pairs of photocells using a two-wire cable.
Connecting multiple pairs of NICE EPMB photocells to the NICE BlueBUS data network
Position the photocells around the gate according to the example layouts for full wiring, and set the jumpers according to the jumper table for the NICE EPMB photocells. To prevent interference between closely positioned pairs, observe the orientation of the transmitters TX and receivers RX as shown in the example layouts. Connect the photocells in parallel as shown (polarity does not matter):
If you need the photocells to work as gate openers (see FA1 and FA2 in the example layouts), i.e. to trigger opening when a vehicle enters the space between their optical axes, cut link A on both the transmitter TX and receiver RX – see figure:
Example photocell wiring layout
NICE EPMB photocell jumper table
![]() |
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations. Each connected pair must have a unique combination; no two pairs in one BlueBUS data network may have the same setting. Set the jumper identically on the transmitter TX and receiver RX of each pair. Keep unused jumpers for future use. |
| Photocell pair designation | Jumper – jumper combination |
|---|---|
| PHOTO | ![]() |
| PHOTO II | ![]() |
| PHOTO 1 | ![]() |
| PHOTO 1 II | ![]() |
| PHOTO 2 | ![]() |
| PHOTO 2 II | ![]() |
| PHOTO 3 | ![]() |
| FA1 (Break the connection A on both TX and RX) |
![]() |
| FA2 (Break the connection A on both TX and RX) |
![]() |
If a photocell needs to be replaced, set the jumper on it to match the original one – there is no need to repeat the device recognition phase.
Installing photocells in the drive unit
Hi-Speed drive unit Nice Robus RBS600HS offers the option to integrate photocells under the drive unit cover. To install the photocell inside the drive unit, you need to purchase the RBSKITSAFE1 kit for installing reflector photocells EPMOR or EPMOB.
Nice Robus RBS600HS can also accommodate what is known as a white status light, which is available to purchase separately as ELMM.
Installing photocells under the cover
1. Open the locking hook (A) using the supplied key.
2. Loosen the screws.
3. Remove the cover.

4. Insert the holder (D) into the pins (E).

Installing the photocell EPMOR is shown below. The procedure described also applies to installing the EPMOB.
5. Remove the covers (F) by loosening the screws (G).

6. Remove the photocell (H) by loosening the screw (I) and removing the nut (L).

7. Fasten the photocell to the bracket (M) using the same screw and nut
that you removed earlier.
CAUTION! Pay attention to the photocell's installation direction.

8. Connect the device.

CAUTION! Before proceeding with final fastening,
check that the photocell is aligned with the reflector unit
(EPMOB or EPMOR).

9. Secure the photocell permanently to the mounting bracket.
Take care not to apply excessive pressure to the holder.

10. Connect the ELMM LED light (N).
This LED light illuminates the passageway and also enables diagnostics through its signaling function.

11. Secure the LED light using the clip (O).

12. Connect the wires according to the markings.

13. Position the drive unit cover, tighten the screws, close the drive unit's locking hook, and remove the supplied key
Gate lighting: white status light
The white status light for the Nice Robus RBS Hi-speed drive unit (ELMM module) is an integrated white LED light built into the drive unit body. It illuminates the gate and also indicates the device status through its signaling functions. It makes visual diagnostics easier.
| Status light / White status light | |
|---|---|
| Lit | The automation system is moving or has just stopped – the light switches off automatically after the programmed time. |
| Lit for 3 seconds | The “lock automation” command has been executed. |
| Off | Normal operation / the gate is stationary and waiting for commands. |
Radio receiver for drive units
NICE Robus Hi-Speed RBS600HS drive unit has a radio receiver built into the control unit NICE MCU4. The MCU4 also has an SM connector (under the plastic cover) for connecting an external radio receiver NICE OXIBD (or an older NICE OXI). The SM connector makes it easy to upgrade from an older Robus RB drive unit to a Robus RBS while retaining the paired remote controls.
Selecting the gate's direction of travel
The direction setting must match the position of the drive unit relative to the gate leaf. View the gate from the side where the drive unit is located.
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
| The switch is on the right-hand side of the back of the MCU4 control unit. |
|
Recognizing connected drive-unit devices
After connecting, disconnecting, or changing the wiring of any devices on the BlueBUS and STOP inputs, perform the accessory recognition phase. The drive unit indicates this by flashing LEDs L1 and L2.
![]() |
|
Recognizing the gate leaf length
To correctly calculate the acceleration/deceleration distance and partial opening, the operator must determine the length of the gate leaf. During this operation, it moves the gate from stop to stop and determines the length using a switch.
Programming the operator
The Robus Hi-Speed RBS600HS operator allows you to program several functions, either by enabling/disabling a function through Level I programming or by setting a preset parameter through Level II programming.
The MCU4 control unit has three buttons for operating and programming the operator:
Programming – Level I
At Level I, programming enables/disables the selected function.. When a function is enabled, its corresponding LED on the control unit lights up. All functions are disabled by default.
Entering Level I programming Press and hold “Stop/Set” for about 5 seconds, until the LED L1. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each action; otherwise, the operator exits the mode. When the flashing LED is next to the function you want to change, press “Stop/Set” to make it flash faster (function enabled) or slower (function disabled), then let the operator exit the mode within 20 seconds. If everything has worked correctly, the corresponding LED will stay lit.
List of functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing | After the set time (“Level II programming – Pause duration”), the gate closes automatically after opening. If this function is disabled, the gate responds only to a command (e.g. from a remote control or similar). |
| L2 | Close after photocell interruption | Once the photocells are clear (the vehicle has passed), closing starts after 5 seconds. The behaviour depends on L1:
|
| L3 | Always close | After a power failure, the gate either stays in its original position (disabled) or closes automatically (enabled). |
| L4 | Standby mode | Reduces power consumption to a minimum (useful with PSS124). One minute after the last movement, BlueBUS (and connected devices) and all LEDs except the BlueBUS LED switch off (the BlueBUS LED flashes slowly). When a command is received, the control unit first wakes up/restarts and only then executes the command. |
| L5 | Acceleration | Disables the soft start—the motor immediately runs at full power (useful in conditions of high friction, snow or ice). Reduces the operator’s service life. |
| L6 | Pre-flashing | Before the gate starts moving, the warning light flashes for 3 seconds before the manoeuvre starts. |
| L7 | Disable the built-in radio control | Switches off the radio receiver built into the control unit. Enable this if you use an external plug-in receiver such as an OXI. If this function is disabled, the internal receiver is active. |
| L8 | “Slave” mode – subordinate unit | When activated, the operator becomes the “Slave”. Allows two motors on opposing gate leaves to be synchronised (Master/Slave). For details, see the Robus RBS manual, section “Slave mode”. |
Programming – Level II
At Level II, function values are set (unlike at Level I).
Entering Level II programming Press and hold “Stop/Set” for about 5 seconds, until LED L1 starts flashing. Use the “Open” and “Close” buttons to move the active LED up or down. You have 10 seconds for each action; otherwise, the operator exits the mode. When the LED is next to the function whose parameter you want to adjust, press and hold “Stop/Set” to enter the settings. The LED that lights up (while you continue to hold “Stop/Set”) indicates the current value. Change the value using “Open” (up) or “Close” (down), then release “Stop/Set” and wait for the operator to exit the mode within 20 seconds. To verify the setting, repeat the procedure without changing the value.
List of adjustable functions:
| Input LED — Name and description | LED settings — Value |
|---|---|
| L1 — Pause duration If “Automatic closing” is enabled at level I, this sets the interval between opening and automatic closing. |
L1 — 5 s L2 — 15 s L3 — 30 s L4 — 45 s L5 — 60 s L6 — 80 s L7 — 120 s L8 — 180 s |
| L2 — Step-by-step mode Sets the movement sequence for repeated commands (remote control button or STEP-BY-STEP/P.P./Step-by-step input). Note: for L4, L5, L7 and L8, the behavior of the “Open” and “Close” commands changes. |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Open/Close/Open/Close L4 — Condominium mode L5 — Condominium mode after two “Stop” commands L6 — Step-by-step mode after two “Partial opening” commands L7 — Presence of a person L8 — “Semi-automatic” opening; closing when a person is detected |
| L3 — Motor speed Speed during normal operation (not acceleration or deceleration). „L6 – Extremely fast” = 100% of 0.34 m/s, etc. |
L1 — Very slow (30%) L2 — Slow (44%) L3 — Medium (58%) L4 — Fast (72%) L5 — Very fast (86%) L6 — Extremely fast (100%) L7 — Opens “Fast”, closes “Slow” L8 — Opens “Extremely fast”, closes “Fast” |
| L4 — OGI output indicator Sets the function of the OGI output (when activated, it supplies 24 V, −30%/+50%, max. 10 W). |
L1 — Gate opening L2 — Gate closed L3 — Gate open L4 — Second radio output L5 — Third radio output L6 — Fourth radio output L7 — Maintenance L8 — Electric lock |
| L5 — Motor force Adjusts the force control to the weight of the automation system. The system also takes the ambient temperature into account and increases the force in cold weather. |
L1 — Extremely light gate L2 — Very light gate L3 — Light gate L4 — Average-weight gate L5 — Medium-heavy gate L6 — Heavy gate L7 — Very heavy gate L8 — Extremely heavy gate |
| L6 — Partial opening Travel distance for partial opening. |
L1 — 0.5 m L2 — 1.0 m L3 — 1.5 m L4 — 2.0 m L5 — 2.5 m L6 — 3.0 m L7 — 3.4 m L8 — 4.0 m |
| L7 — Maintenance warning Number of maneuvers after which the drive indicates that maintenance is required. |
L1 — 1,000× L2 — 2,000× L3 — 4,000× L4 — 7,000× L5 — 10,000× L6 — 15,000× L7 — 17,000× L8 — 20,000× |
| L8 — Fault list Check the type of fault from the last 8 maneuvers (see “Fault history” in the manual). |
L1 — Result of the 1st maneuver L2 — Result of the 2nd maneuver L3 — Result of the 3rd maneuver L4 — Result of the 4th maneuver L5 — Result of the 5th maneuver L6 — Result of the 6th maneuver L7 — Result of the 7th maneuver L8 — Result of the 8th maneuver |
Procedure after resetting the NICE ROBUS RBS600HS drive with integrated Wi-Fi
| Important: setup sequence after reset |
|---|
| 1. Connect MyNice Pro and update the firmware With the power off, connect the BiDi-WiFi programmer to the BUS T4 connector, then switch on the power. In the MyNice Pro programming app, first add and pair BiDi-WiFi as a programming interface; if it is already saved in the app, connect to it. Once the connection is confirmed, search for the control unit. Check for an available firmware update, download the latest compatible version, and install it. Do not switch off the power or disconnect the programmer during the update; wait for confirmation that it is complete. This step must be carried out by an installer with a Company account. A guest account does not support firmware updates for the control unit. |
| 2. Prepare the gate Clear the gate’s path of movement. Use the key to release the drive, move the gate to approximately halfway along its travel, then secure the drive again. |
| 3. Accessory learning Press OPEN ▲ and STOP/SET simultaneously for approximately 3 seconds. When LEDs L1 and L2 start flashing rapidly, release the buttons. Wait until the learning process is complete: L1 and L2 will turn off and the STOP LED will remain lit. |
| 4. Gate travel learning Press STOP/SET and CLOSE ▼ simultaneously for approximately 3 seconds. Release the buttons when the gate starts moving. The gate will close first, then open fully, and close again. Wait until the process is complete; LEDs L3 and L4 will turn off. If it starts opening first, press STOP/SET immediately and have the direction setting checked. |
| 5. Disable Standby mode In the unit settings in MyNice Pro, set Standby mode to OFF. When the gate is stationary and not in programming mode, the corresponding LED L4 on the unit should be off. Disabling Standby mode will increase the drive’s power consumption while idle. |
| 6. Check and, if necessary, pair the integrated Wi-Fi via MyNice Once the settings are complete, switch off the power, disconnect the external BiDi-WiFi programmer, then switch the power back on. In the MyNice customer app, check whether the drive is still available. If it has not yet been added in the app, or its built-in Wi-Fi has been reset separately, start adding the device and follow the setup guide to pair the drive’s integrated Wi-Fi. Have the name and password for your 2.4 GHz home Wi-Fi network ready. When pairing for the first time: connect your phone to the 2.4 GHz home Wi-Fi network that you are connecting the drive to; do not leave it connected only via 5G mobile data. The drive does not support 5 GHz Wi-Fi. 5G mobile networks and 5 GHz Wi-Fi are different things. After pairing, you can also use MyNice remotely via mobile data. |
| 7. Final check Try operating it using both MyNice and the remote control. The installer must check the limit positions, photocells, and safe drive settings, because the reset has removed the original custom settings. |
Automating two opposing sliding gates using two NICE Robus Hi-Speed RBS600HS drives (Master-Slave mode)
If you need to automate two sliding gates facing each other, Robus drives support slave mode (“Master-Slave”). One drive is the master (Master) and sends commands to the other, the slave (Slave). All Robus drives are configured as masters at the factory, so enable function L8 (Slave unit). Connection Master ↔ Slave is made via BlueBUS.
Restrictions for connecting the master and slave units
- The gate cannot be opened using the slave unit.
- All devices (e.g. photocells, external receiver etc.) must be connected to the master unit. Only a warning light, devices connected to the STOP, SBS (STEP-BY-STEP) input, and the output indicator OGI; the OPEN/CLOSE inputs are ignored.
- If you use a backup battery (NICE PSS124), each drive must have its own.
- On the slave unit, all programmed functions are ignored except those listed below.
| Level I programming | Level II programming |
|---|---|
| L4 — Standby mode | L3 — Motor speed |
| L5 — Start-up | L4 — Output indicator |
| L8 — Slave unit | L5 — Motor force |
| L8 — Error log |
Installing two Robus drives in slave mode
- Install both gate leaves and both motors. Decide which one will be the Master (N) and which one will be the Slave (P). In Master-Slave mode, only the slave gate leaf can be fully opened.
- (P) Select the opening direction (direction switch on the control unit).
- (P) On the Slave, run the device and gate-leaf length learning procedure (“Device learning”, “Gate-leaf length learning”). If the direction is reversed, repeat step 1.
- (P) On the Slave, enable the “Master-Slave mode” (Level I, L8).
- (P+N) Connect the two automation systems as shown in the diagram.

- (N) Select the opening direction on the Master.
- (N) On the Master, run the device and gate-leaf length learning procedure. The Slave will also move while the gate-leaf length is being learned. If the direction is reversed, repeat step 6.
Connecting additional external devices
To the control unit
The MCU4 control unit has available 24 V DC (+), GND (−) for powering external devices, as well as terminals for OGI, BlueBUS and Flash.. In Master-Slave mode, connect devices to the master drive (for exceptions concerning the “Slave” see the manual – “Master-Slave mode”).
Expanding the control unit with additional inputs/outputs
In addition to the terminals provided, the control unit also has a built-in expansion board MLAE22, which allows you to connect multiple devices.
The MLAE22 board provides 2 outputs (one of which is 230 V) and 2 inputs for connecting accessories to the control unit.
Default values (can be changed in the control unit settings):
| Contact | Gate | Door |
|---|---|---|
| A | OPEN | OPEN |
| B | CLOSE | CLOSE |
| C | Gate status indicator |
One-way traffic light
|
| D | Auxiliary light | Auxiliary light |
| E | 230V | 230V |
| F | Neutral | Neutral |
Replacing the expansion board
The expansion board However, the MLAE22 can be removed and replaced with another one, according to your preference.
The number and type of inputs and outputs on the expansion boards depend on the type of board. There are currently 3 types available for the MCU4 of expansion boards:
MLAE21 - 2x 24V inputs (factory-set to Open and Close), 1x 24V output (factory-set to OGI)
MLAE22 - 2x 24V inputs (factory-set to Open and Close), 1x 24V output (factory-set to OGI), 1x 230V output (factory-set to Lighting) - built-in
MLAE44 - 4x 24V inputs (factory-set to Open, Close, Partial Opening, Photo), 4x 24V outputs (factory-set to OGI, Gate Closed, Radio Output 4, Photo Test)
Procedure for connecting the expansion board:
Adding or removing expansion boards must always be done with the power switched off (by removing fuse F2 and, if connected, the backup battery).
Procedure for learning additional devices.
After adding or removing devices, the automation system must be tested again as described in the section “Testing” (see the drive manual).
Special drive functions
Gate held open
If a command to the STEP-BY-STEP input (P.P., SbS, Step-by-step) lasts longer than 2 seconds, the control unit will hold the gate open for as long as the command is active. Suitable for use with a timer.
Forced operation
If a safety device fails or an obstacle blocks, for example, the photocells and the gate does not move for safety reasons, activate “Hold-to-run mode” — permanently (Level II, L2 = L7) or temporarily:
- Send a command (e.g. remote control or key switch).
- If there is a problem, the gate will not move and the warning light will probably indicate a fault.
- Within 3 seconds of the previous command, send it again and hold it.
- The gate moves while the command is held; it stops when the command is released.
Maintenance alert
In Level II Programming, item L7 – Maintenance warning sets the number of cycles after which the drive should signal that maintenance (inspection) is required. The drive signals this using the warning light (or, if Level II Programming item L4 – Output indicator is set to level L7 – Maintenance) as follows:
| Number of cycles | Warning light signal | OGI output indicator signal |
|---|---|---|
| less than 80% of the limit | Normal operation, flashing at half-second intervals. | “On” for 2 seconds after opening begins. |
| 80–100% of the limit | On for 2 s after the maneuver starts, then operates normally. | Flashes during the maneuver. |
| more than 100% of the limit | On for 2 s after the maneuver starts, then operates normally; on again for 2 s after the maneuver ends. | Flashes continuously. |
These settings can also be configured using the mobile app MyNice Pro.
Troubleshooting the drive
If anything is unclear or you have another issue, please feel free to contact our technical support team for NICE drives.
Depending on the nature of the problem
During installation (or if the drive fails), you may encounter one of the following problems:
| Problem | Possible solution |
|---|---|
| The gate does not respond to a remote-control command, and the LED on the remote control does not light up. | Check that the batteries in the drive remote control are working; if not, replace them (instructions are in the manual for the specific remote control). |
| The gate does not respond to a remote-control command, but the LED on the remote control lights up. | Check whether the remote control has been stored correctly in the receiver's memory ; otherwise, store it again. |
| The gate does not move and the BlueBUS LED does not flash. | Check that the operator is powered at 230 V. If it is, test both fuses and replace them with new ones of the same rating if necessary. |
| The gate does not move and the warning light does not flash. | Check whether the operator has registered the command at all: – when the command is sent from the remote control the BlueBUS LED should flash quickly twice; – when the command is sent via the STEP-BY-STEP (SbS) input, the corresponding STEP-BY-STEP LED should light up. |
| The gate does not move and the warning light flashes several times. | Count the flashes and see the section “Diagnostics using warning-light flashes” below. |
| The gate starts moving, but soon stops and reverses. | The motor force is probably programmed too low. Check that nothing is obstructing the gate and increase the force if necessary; you can also enable the “Start-up“. |
| The gate starts moving, but the warning light does not work. | Check whether voltage (approx. 10–30 V DC) is present at the FLASH terminal during operation. If voltage is present, the problem is with the warning light – try replacing it. If there is no voltage, the FLASH output may have been overloaded – check the wiring for a short circuit. |
| The gate starts moving, but the OGI output does not work. | Check which function is assigned to the OGI output; if it is meant to flash, check that 24 V DC is present. If voltage is present, the problem is with the bulb – replace it. If there is no voltage, the OGI output may have been overloaded – check the wiring for a short circuit. |
Diagnostics using warning-light flashes
While the gate is operating, the warning light flashes regularly once per second. When a problem occurs, it signals the error with two faster sequences of flashes in succession.
| Flash sequence | Error | Solution |
|---|---|---|
| 1 flash, 1 s pause, 1 flash | BlueBUS error | The devices connected to the BlueBUS input do not match those detected during the setup phase. Run the setup phase again; if that does not help, use the process of elimination to identify the faulty device, then replace it, have it repaired, or make a warranty claim. |
| 2 flashes, 1 s pause, 2 flashes | Photocell activation | The photocells are being triggered (normal if the beam is interrupted while closing). If the beam was not interrupted, they may be dirty, affected by glare, or faulty. |
| 3 flashes, 1 s pause, 3 flashes | Motor force limiter activated | The gate is detecting increased friction – check and adjust the gate (test its manual movement). Increasing the force or enabling “Start-up“. The problem may also be caused by an excessively high bottom stop. |
| 4 flashes, 1 s pause, 4 flashes | STOP input activated | A command was received at the STOP input. If this was not expected, check the connected devices. |
| 5 flashes, 1 s pause, 5 flashes | Internal control unit error | Wait at least 30 seconds, then send the command again. If the error persists, try a reset. The control unit will probably need to be repaired or replaced. |
| 6 flashes, 1 s pause, 6 flashes | Hourly operation limit reached | Wait a few minutes for the cycle limiter to drop below the maximum. |
| 7 flashes, 1 s pause, 7 flashes | Internal electronic circuit error | Disconnect the operator from the power supply for a few seconds, reconnect it, and try sending the command again. If the error persists, try a reset. If that does not help, the control unit will probably need to be repaired or replaced. |
| 8 flashes, 1 s pause, 8 flashes | Continuous command active | If a command is being sent continuously to the operator, check the devices connected to the OPEN input. If a timer is connected, it is probably sending this continuous command. |
Diagnostics using LED flashes
Diagnostics can be performed by monitoring several sets of LEDs. Two sets are on the control unit, and the third is the status light directly on the operator.
On the operator...
The status light is on the front of the cover of the Nice RBS operators.
The red and green LEDs indicate normal operation and provide basic gate diagnostics, as shown in the table below. If the operator detects an anomaly or error, it signals it using the warning light.
| Status light with travel limits learned | |
|---|---|
| Green light | |
| on | Indicates the start of each gate movement, if there are no anomalies or errors in the system, and switches off when the movement ends. |
| off | Normal operation |
| Red light | |
| on | Indicates the start of each gate movement, if the set number of movements before maintenance has been exceeded; and switches off when the movement ends. |
| off | Normal operation |
| Warning light | The control unit has detected an anomaly. See the table “Diagnostics using warning-light flashes”. |
| Status light with travel limits NOT learned | |
|---|---|
| Green light | |
| on | The light turns on when the opening limit switch is reached. |
| off | Normal operation |
| Red light | |
| on | The light turns on when the closing limit switch is reached. |
| off | Normal operation |
| Flashing beacon | The control unit has detected an anomaly. See the table “Beacon flash diagnostics.” |
On the MCU4 control unit...
Control unit MCU4 for the NICE Robus Hi-Speed RBS600HS has two sets of LEDs, each of which uses flashing and steady lights to indicate normal operation of the control unit or diagnose faults, as shown in the tables below.
Horizontal LEDs: BLUEBUS, STOP, SbS, FOTO:
| Indicator | Status | Solution |
|---|---|---|
| BlueBUS LED | ||
| off | anomaly/fault | Check the mains connection. If it is correct, check fuses F1 and F2 and, if necessary, replace them with new fuses of the same rating. |
| on | serious fault |
Try disconnecting the control unit, and if necessary, all inputs. If this does not help, reset the control unit. If the fault persists, the control unit will probably need to be replaced. |
| 2 green flashes at one-second intervals | all OK | The control unit is operating normally. |
| 2 quick green flashes | input status has changed |
Normal operation – the status of the STEP-BY-STEP, STOP, OPEN or CLOSE input has changed, or the following were activated: photocells, or the drive received a command from a remote control. |
| a series of red flashes separated by a one-second pause | various | The number of flashes in the sequence indicates the fault, as diagnosed by the beacon. See “Beacon flash diagnostics”. |
| a sequence of quick and slow red flashes | short circuit at the BlueBUS terminal | Disconnect the terminal and check the BlueBUS connections for the cause of the short circuit. Once the short circuit has been fixed, reconnect the terminal. The LED will start flashing again after ten seconds. |
| STOP LED | ||
| off | STOP input activated | Check the devices connected to the STOP input. |
| on | STOP input did not respond | The STOP input is active. |
| STEP-BY-STEP LED (also labelled SbS, P.P. or Step-by-step) | ||
| off | all OK |
The STEP-BY-STEP input is inactive. |
| on | STEP-BY-STEP input activated | Normal operation of the control unit when a device connected to the STEP-BY-STEP input is active. |
| FOTO LED | ||
| off | FOTO input activated | The FOTO input has been triggered. |
|
on |
All OK | Normal operation of the control unit when the safety device has not been triggered. |
Vertical LEDs L1–L8:
| Indicator | Solution |
|---|---|
| LED 1 | |
| off | During normal operation, this indicates that the “Automatic closing” function is disabled. |
| on | During normal operation, this indicates that the “Automatic closing” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 2 | |
| off | During normal operation, this indicates that the “Close” function after the photocells are interrupted is disabled. |
| on | During normal operation, this indicates that the “Close” function after the photocells are interrupted is enabled. |
| flashing |
- The function is being programmed.
|
| LED 3 | |
| off | During normal operation, this indicates that the “Always close” function is disabled. |
| on | During normal operation, this indicates that the “Always close” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 4 | |
| off | During normal operation, this indicates that the “Standby mode” function is disabled. |
| on |
During normal operation, this indicates that the “Standby mode” function is enabled. |
| flashing |
- The function is being programmed.
|
| LED 5 | |
| off | During normal operation, this indicates that the “Starting” function is disabled. |
| on | During normal operation, this indicates that the function “Soft start” is enabled. |
| flashes | Function programming is in progress. |
| LED 6 | |
| is off | During normal operation, this indicates that the function “Pre-flashing” is disabled. |
| is on | During normal operation, this indicates that the function “Pre-flashing” is enabled. |
| flashes | Function programming is in progress. |
| LED 7 | |
| is off | During normal operation, this indicates that the function “Internal radio receiver” is disabled. |
| is on | During normal operation, this indicates that the function “Internal radio receiver” is enabled. |
| flashes | Function programming is in progress. |
| LED 8 | |
| is off | During normal operation, indicates that Robus is configured as a “Master” (also called Master). |
| is on | During normal operation, indicates that Robus is configured as a “Slave” (also called Slave). |
| flashes | Function programming is in progress. |
Installing a backup battery in the NICE Robus Hi-Speed RBS600HS operator
The backup NICE PSS124 battery is not supplied as standard with the operator, but can be ordered separately. If the power fails, it will power the gate operator. The battery is continuously recharged from the mains. Connect the battery to the control unit only after completing all installation and programming steps.
Manually releasing the NICE Robus Hi-Speed RBS600HS operator
If there is a power failure or malfunction, you will not be able to operate the gate using the remote control. You can therefore release the operator with the release key and move the gate manually.
1. Unlock the locking hook (A) with the supplied key and pull out the release lever. You can now move the gate manually.
2. To lock the gate, close the locking hook, turn the key counterclockwise, and remove it.
Technical specifications of the NICE Robus Hi-Speed RBS600HS operator
| Model | NICE Robus Hi-Speed RBS600HS |
|---|---|
| Description | High-speed electromechanical gearmotor for automatic operation of sliding gates in residential settings. Supplied with a NICE MCU4 control unit featuring an integrated radio and Wi-Fi receiver. |
| Max. gate length | 8 m |
| Max. gate weight | 600 kg |
| Power supply | 230 V (+10%/-15%), 50/60 Hz |
| Speed | 0.44 m/s |
| Pinion | Number of teeth: 15 Module: 4 Pitch: 12.6 mm Pitch diameter: 60 mm |
| Rated torque [Force] |
9 Nm [300 N] – force required to keep the gate leaf moving |
| Max. starting torque [Force] |
18 Nm [600 N] – force required to start the gate leaf moving |
| Power consumption [Load] |
450 W [3.1 A] |
| Max. power consumption at start-up [Load] |
650 W [3 A] |
| Protection rating | IP44 |
| Limit for consecutive operating cycles | 100 cycles/day (the control unit limits the number according to conditions – see operator selection) |
| Operating time limit | 6 minutes (the control unit limits the time according to conditions – see operator selection) |
| Service life | Approximately 20,000–250,000 cycles, depending on the weight and length of the gate leaf and the operator settings. |
| Power supply | 230 V (+10% / −15%) 50/60 Hz |
| Insulation class | 1 – must be earthed |
| Backup power supply | Optional NICE PSS124 backup battery available for purchase and installation. (When using the adapter CABLA11 An older model can also be used PS124.) |
Technical specifications of the NICE Robus Hi-Speed RBS600HS operator:
| Speed | 0.44 m/s |
|---|---|
| Power supply | 230V, 50/60Hz |
| Power consumption | 450W |
| Torque | 5.9Nm |
| Max. torque | 9.3Nm |
| Max. gate weight | 600kg |
| Protection rating | IP 44 |
| Operating temperature | -20°C to +55°C |
| Rack module | 4 |