NICE barriers and boom gates
Professional barrier gates from Italian manufacturer Nice
Barrier gates are a simple and effective way to control entry to and exit from sites, businesses, companies, car parks, and other secure areas. A barrier gate can therefore serve as a parking barrier, road barrier, entrance barrier, or security barrier alongside a sliding gate.
In this article, you’ll learn about:
- Features and benefits of barrier gates
- Types of barrier gates
- Comparing models and cycles
- Boom length and clear opening
- Special offers
- Our range of barrier gates and parking barriers
- Barrier gate control options
- Installation example
- Barrier gate video presentation
- Site preparation for barrier gates
- Barrier gate speed
Advantages of barrier gates
- Reliable equipment
- Space-saving, with minimal site preparation required
- High-quality finish with lasting colour
- Stainless-steel (INOX) barrier gate housing also available
- A wide range of control options
- Option to connect backup power supply, and, on compatible BAR models, Solemyo solar power
- Easy manual release (in the event of a power cut)
- We’ll put together the ideal setup for your specific needs.
- Certification
Types of barrier gates
We divide Nice barrier gates into the WIDE and BAR ranges. When choosing, compare the specific model, the required clear opening, the number of openings per hour, and the control options you need.
NICE WIDE models are suitable for standard use and, depending on the model, handle up to 100–300 cycles per hour. They can be fitted with a backup battery.
NICE BAR models do not all have the same performance. The M3BAR is suitable for very intensive use and fast vehicle throughput. For the M5BAR, M7BAR, and L9BAR, boom length is also a factor. The S-BAR is rated for a maximum of 100 cycles/hour, less than the WIDE M.
Control unit and backup battery
The WIDE has simple settings for everyday use. The BAR range offers more advanced functions. The S-Bar has its own control unit, different from those used in the M-Bar and L-Bar.
| Barrier gate range | Control unit | Backup battery |
|---|---|---|
| WIDE S, M, L | WIA20R10: microswitches and trimmers. | PS324 |
| S-Bar | XBA20R10: buttons and LED. | PS124 |
| M-Bar, L-Bar | BCU1R10: display and joystick. | PS224 |
The S-Bar supports cycle counting and service alerts. The M-Bar and L-Bar also allow two opposing barrier gates to be synchronised in master/slave mode.
Comparing models and maximum number of cycles
One cycle consists of opening and closing the barrier gate. The key factor is the number of openings during the busiest hour, not just the daily average.
| Model | Max. cycles/h | Opening time |
|---|---|---|
| WIDE S | 100 | from 4 s |
| WIDE M | 300 | from 3.5 s |
| WIDE L | 200 | from 5 s |
| S-BAR | 100 | from 4 s |
| M3BAR | 500 | 1.5–4 s |
| M5BAR | 350 | 3–6 s |
| M7BAR | 200 | 6–10 s |
| L-BAR (L9BAR) | 150 | 11–18 s |
These are the manufacturer’s maximum figures at the rated load. The actual operating frequency depends on the boom, accessories, and settings. For the S4BAR with XBA4 lighting, the maximum is 80 cycles/h and the opening time is over 5 s. The stated cycle figures do not guarantee the number of vehicles that can be processed.
BlueBUS, backup battery, and solar power
BlueBUS makes it easier to connect compatible photocells and other accessories using two wires. These carry both power and communications for the accessories. The S-BAR, M-Bar, and L-Bar use BlueBUS, while WIDE models use standard relay photocells.
When ordering photocells, choose the correct type: for WIDE, relay-type EPM, for S-Bar, M-Bar, and L-Bar, EPMB with BlueBUS.
Backup battery is connected separately, not via BlueBUS. It is also available for WIDE models. Solemyo solar power is designed for compatible BAR models; it is not supported by WIDE. Choose the specific solar kit according to the model and its control unit. Mobile phone control is a separate add-on, depending on the module used.
The barrier gates use 24 V motors, allowing them to be used in near-continuous operation. The barriers have amperometric protection. When the barrier arm hits an obstacle, the current draw increases and the control unit detects that the arm has hit an obstacle. After detecting an obstacle, the arm can stop or return to the open position (depending on the settings).

Value bundles
We offer barriers in discounted bundles. In addition to the barrier and arm, these also include accessories such as receiver, remote control, photocells and warning light. The bundle also includes impact-absorbing rubber for the arm, and bundles with two arms also include an connector for these arms.
We primarily group the bundles by the arm length and the barrier model, which will raise the arm. Arms are available in lengths of 3, 4 and 5 metres, but thanks to the original connector, the overall length can be configured up to 9 metres. We classify the barriers by their power, arm lifting speed and the number of cyclesthey perform per hour.
Arm length and clear passage width
The arm length is not the same as the clear passage width. The clear passage width is the unobstructed width available to a vehicle when the barrier is open. First measure the required passage width, then choose the arm and barrier according to the installation drawing.
| Model | Clear passage width according to the manual | Arm included (nominal length) | Bundles available |
|---|---|---|---|
| WIDE S | Depending on installation* | 4 m | 4 m bundle |
| WIDE M | Depending on installation* | 4 m | 4 m bundle |
| WIDE L | Depending on installation* | 5 / 6 / 7 m | 5 m bundle 6 m bundle 7 m bundle |
| S-BAR | up to 4 m | 4 m | 4 m bundle |
| M3BAR | 2.32–2.82 m | 3 m | 3 m bundle |
| M5BAR | 3.17–4.82 m | 4 / 5 m | 4 m bundle 5 m bundle |
| M7BAR | 5–7 m | 6 / 7 m | 6 m bundle 7 m bundle |
| L-BAR (L9BAR) | 7–9 m | 8 / 9 m | 8 m bundle 9 m bundle |
* For WIDE models, the stated figure is the nominal length of the arm included in the bundle, not a guaranteed clear passage width. The clear passage width depends on the position of the housing and how the arm is mounted. For M-Bar/L-Bar, the ranges shown are taken from the manuals for M3BAR, M5BAR, M7BAR and L9BAR. Accessories fitted to the arm may reduce its usable length.
For example, the arm NICE XBA15 is physically 3,150 mm long. For M3BAR, the manual specifies a maximum clear passage width of 2.82 m. Therefore, the “3 m” bundle designation does not automatically mean a 3 m clear passage width.
We can tailor bundles to your requirements for specific applications.
Our range of barriers and barrier arms
We also offer barriers and arms individually, so you can put together the complete setup yourself. However, you need to ensure that the individual parts are compatible. We’ll be happy to advise you. Technical support is also available.
Our range also includes other barrier accessories, such as arm support, fold-down support, aluminium skirt for the barrier arm or articulated joint for arms for low-clearance spaces.
For low-clearance spaces: articulated joint WIA11 is for WIDE M, XBA11 for M3BAR and M5BAR. Measure the ceiling height before choosing. For support and under-rail installations, check the approved combination with the arm and ensure it is properly balanced.
A separate category is safety. Nice barriers have integrated obstacle detection, which makes the arm immediately reverse after hitting an obstacle.
For added safety, the barrier can also include safety photocells, protective rubber strips or various warning beacons, traffic lights and lights. Recommended accessories include reflective stickers, which are applied directly to the barrier arm. They improve the visibility of the arm itself and help prevent frequent collisions with it.
An external traffic light can be connected to both WIDE and BAR. The built-in XBA8 for the top cover is designed for M-Bar and L-Bar. For an external traffic light, select the correct voltage, power consumption and wiring for the control unit.
A strong impact to the arm can damage the barrier arm. Selected models can be fitted with a pivoting mount, which helps reduce damage to the barrier in the event of an impact.
- NICE WIA10 - bracket for sideways arm release for WIDE S and WIDE M, with arms up to 4 m long.
- NICE XBA10 - bracket for sideways arm release for M3BAR and M5BAR, with arms up to 4 m long.
This is an optional accessory. This is not a standard automatic arm release fitted to every barrier.
A popular addition to a barrier is a magnetic metal detector. It can detect metal parts of a vehicle and then send a command to the barrier. This can create a fully automated system that opens the barrier when a vehicle is detected, or a parking-space counter that tracks vehicles entering and leaving.
Detectors are available for compatible M-Bar and L-Bar control units: LP21 and LP22 and an induction loop installation kit. The detector itself detects vehicles. Counting available spaces or managing alternating traffic with traffic lights also requires a suitable control system.
Barrier control options
A barrier is an electronic device that is most commonly operated using a standard remote control. It can be purchased and paired at any time. It can also be easily deleted from the system. The receiver in the barrier can work with hundreds of remote controls (for example, the NICE OXIBD receiver has a capacity of 1024 codes).
Remote controls and receivers in our range
For everyday operation, choose from several NICE ranges with rolling code technology. As with Robus operators, compatibility with the receiver and its coding system is what matters.
| Use | Remote control and receiver |
|---|---|
| FloR and Era FloR | FLO2R-S and FLO2RE: 2 channels. FLO4R-S and FLO4RE: 4 channels. |
| Era One | ON2E: 2 channels. ON4E: 4 channels. ON9E: 9 channels. |
| Era INTI | Two-channel remote controls in the following colors: INTI2 black, INTI2Y yellow, INTI2L pink, INTI2B blue, INTI2R red, INTI2G green. |
| MYGO | MYGO2, MYGO4 or MYGO8: 2, 4 or 8 channels. |
| Two-way communication | ON3EBD + OXIBD |
| Longer radio range | ON3ELR + OXILR. LoRa requires an OXILR receiver. Range depends on the environment and antenna. |
A kit is also available to add an external receiver: INTIKIT with an INTI receiver and remotes.
Frequency and rolling code alone do not guarantee compatibility. If you’re buying an additional remote for an existing barrier, you can send us the receiver’s label or a photo of it.
All other control options are also available: keypads, card readers, wireless buttons for a wall or gatehouse, automatic timers, key switches or mobile phone control. Another advantage of Nice barriers is the input for external devices from other manufacturers.
The keypad can control up to 3 devices. It’s easy to use: simply enter your own 4–8 digit code on the keypad.
Card readers are a popular control option. Hold a contactless card or key fob against the reader and the barrier opens.
Wireless buttons work like remote controls. Buttons are ideal for a fixed location, such as on a wall next to a light switch.
If you want the barrier to open and close at specific times, then automatic timers. are ideal for you. They send the barrier a command at the set time, specified in hours and minutes.
To mobile phone control use a GSM module or modern solutions via a Wi-Fi module. A GSM module is a device that takes a standard SIM card with its own phone number. When you call that number and hang up, the GSM module sends a command to the control unit to raise the barrier (or open the gate)..
A Wi-Fi module is also a device that connects to the control unit and then sends it commands. A Wi-Fi module works through a mobile app and the internet, but it must be within range of your own (home) Wi-Fi network.
The barrier is self-locking, meaning it is locked when closed. In practice, this means you cannot force the barrier open by hand.. The package includes a release key that disengages the gearbox, after which you can simply raise the barrier. This is mainly used during a power outage.
Example installation
Your order includes complete instructions with drawings and diagrams.
Video presentation of the Nice Wide barrier
In this short video presentation of the Nice Wide barrier, you can see how the barrier operates and what it consists of, as well as a few details, such as: release key; impact protection function, which makes the barrier reverse when it detects an obstacle; articulated joint; boom extension option and more.
If you have any other questions about barriers or need help choosing the right device, please feel free to contact us by email at [email protected]
Site preparation for barriers
The barrier should be anchored to a concrete foundation, ideally below the frost line, at a depth of approximately 80 cm, depending on the location. Each barrier comes with a galvanized steel mounting plate. The plate is used to anchor the barrier. You can find the dimensions of each plate in the product details:
- NICE SIA1 - foundation plate for WIDE S, WIDE M and S-BAR barriers
- NICE SIA2 - foundation plate for the NICE WIDE L barrier
- NICE XBA16 - foundation plate for the M-BAR barrier
- NICE XBA17 - foundation plate for the L-BAR barrier
The mounting plate has an opening for the cable entry. At this point, provide a 220 V supply, ideally on a dedicated 6 A circuit breaker. We recommend separating the low-voltage wiring from the 220 V power supply.
Foundation preparation for NICE WIDE barriers
01. Choose the steps based on the condition of the foundation
Decide where the barrier and each system component will be installed.
- If you don’t have a concrete foundation yet, start at step 02.
- If the concrete foundation is already in place, continue at step 06.
02. Prepare the excavation and cable conduits
Dig a trench for the foundation and prepare conduits for the electrical cables. Cable types are listed in the wiring table below.
03. Attach the anchor bolts to the mounting plate
Attach four anchor bolts to the mounting plate. Secure each one with a nut above and another below the plate.
Important: Screw the lower nut all the way to the end of the thread.
04. Set the mounting plate in concrete
Fill the excavation with concrete and position the mounting plate with the anchor bolts.
Important: Before the concrete sets, use a spirit level to check that the mounting plate is perfectly level.
05. Allow the concrete to cure
Wait for the concrete to cure. The manufacturer generally recommends at least two weeks. Then unscrew the four upper nuts from the anchor bolts.
06. Prepare and secure the barrier housing
- a/b: Unscrew the bolts and remove the top cover.
- c/d: Remove the housing door.
Anchoring to an existing concrete foundation: The following drilling procedure is for installation using expansion anchors, not for a mounting plate with anchors already set in concrete as in steps 03 to 05.
- e/f: Position the housing and mark the anchoring points through the mounting holes.
- g: Drill holes in the substrate at the marked points.
- h: Insert four expansion anchors. Not included.
- i: Position the housing and secure it with nuts and washers. With this anchoring method, nuts and washers are not included.
The remaining wiring depends on the accessories selected. The most common setup is:
| Connection | Nice WIDE | Nice BAR |
|---|---|---|
| I - power supply (230 V) | 1 pc. 3x1,5mm2 | 1 pc. 3x1,5mm2 |
| II - left photocell connection | 1 pc. 2x0,25mm2 | 1 pc. 2x0,5mm2 |
| III - right photocell connection | 1 pc. 4x0,25mm2 | 1 pc. 2x0,5mm2 |
| IV - warning light connection | 1 pc. 2x0,5mm2 1 pc. shielded RG58 (or 50-ohm coaxial cable |
1 pc. 2x0,5mm2 1 pc. shielded RG58 (or 50-ohm coaxial cable |
Barrier speeds

The video compares the speeds of the M5-BAR and L-BAR barriers.
We can help you choose the right solution
Tell us the width of the passage, the approximate number of openings per hour and how you want to operate the barrier. A photo of the entrance or a simple sketch would also help. We’ll be happy to help you choose a barrier and suitable accessories.
Email: [email protected]
Phone: