NICE M7BAR Barrier Gate – Without Boom Arm
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€1,146.58 including VAT
| Weight |
|---|
| 85 kg |
Description of NICE M7BAR Barrier Gate – Without Boom Arm
NICE M7BAR is an electromechanical barrier for controlled vehicle access, supplied without an arm. It has a 24 V DC motor and a built-in control unit BCU1 R10 (XBA3 R10). The standard configuration is powered from the 230 V AC; 24 V is the motor voltage.
It is designed for an arm rated at 5, 6 or 7 m. It has a robust steel housing and a balancing spring. Elliptical aluminium arms XBA15, XBA14 and XBA5 can be joined in approved combinations using XBA9. The exact assembled arm length and its accessories determine the spring setting.
In the event of a power failure, the arm can be released with a key or operated using a PS224 backup battery. The housing can be fitted with a XBA7 warning light or XBA8 traffic light. Two opposing barriers can be synchronized in Master–Slave.
If a barrier is already installed, first check the board marking. The following settings are for the BCU1 R10 with display and rotary selector; the older XBA3 has different controls and is not interchangeable based on a similar name alone.
When to choose the NICE M7BAR
| What to check | Specification and meaning |
|---|---|
| Clear passage width | 5–7 m |
| Adjustable operating time | 6–10 s |
| Max. cycles at rated torque | 200 cycles/h |
| Arm | Supplied separately; component and connector combinations |
| Manual release | With a key during a power failure or servicing |
| Two opposing barriers | Master–Slave synchronization |
The arm length is not the same as the clear passage width. When selecting a model, allow for the space taken up by the housing and bracket; check the final clear width on site. Operating time depends on the settings, the arm and its accessories. The maximum number of cycles does not guarantee unlimited operation under all load conditions.
The barrier is intended for vehicles. Arm movement must not endanger pedestrians; provide a separate pedestrian passage and select safety devices according to the risks at the specific entrance. Before installation, also check the clearance above the arm when it is in the open position.
Arm accessories and their limitations
| Accessory | Condition |
|---|---|
| Rubber and lights | Permitted when the length, wiring and balancing are correct. Choose the light strip according to the actual arm length. |
| Arm skirt WA13 | Only for shorter configurations listed in the spring table. This combination is not permitted with a 7.33 m M7BAR arm. |
| Mobile support WA12 | It is accounted for in the spring table, including with a 7.33 m arm. |
| XBA11 articulated joint | Not permitted for the M7BAR. It is not a solution for low ceilings with this barrier. |
After adding lights, rubber, a support or an arm skirt, reselect the spring attachment and balancing. Increasing the motor power does not replace correct mechanical adjustment.
What are the components of the boom?
| Boom designation | Components | What to check |
|---|---|---|
| 5 m | 1 × XBA5, 5.15 m | Without the XBA9 connector; check the exact length and spring attachment against the configuration. |
| 5 m | 2 × XBA15 + XBA9 | Configuration shortened to 5.00 m according to the spring table. |
| 6 m | 2 × XBA15 + XBA9 | Spring table: 6.33 m. |
| 7 m | XBA15 + XBA14 + XBA9 | Spring table: 7.33 m; shorter section next to the cabinet. |
XBA15 is 3,150 mm long, XBA14 is 4,150 mm and XBA5 is 5,150 mm. Do not use the commercial designations 6, 7, 8 or 9 m as exact installation dimensions. Measure the assembled boom length and clear passage width before installation. The XBA9 connector does not allow the barrier's limits to be exceeded.
Barrier kits with boom and accessories
For a complete assembly with a boom, choose from the available kits. The stated length refers to the boom, not the clear passage width. Kits from different ranges have different control units and limits; open the kit listing to see its specific contents.
| NICE M7BAR barrier kits | |
|---|---|
M7BAR – 6 m boom![]() | M7BAR – 7 m boom![]() |
Accessories compatible with the M7BAR barrier
Choose the equipment to suit the boom length and operating conditions. Even compatible accessories have mechanical and electrical limitations; not all accessories can necessarily be used at the same time.
| What | Why | Type |
|---|---|---|
| The cabinet is supplied without a boom. Choose the sections and connector according to the exact length. | ||
| Joins two boom sections; installation procedure. Use the connector only with compatible sections specified for this barrier. | ||
| Height-adjustable support for the end of the closed boom. This is not a support attached to the boom. | ||
| Folding support attached to the boom. Check the permitted lengths and its load capacity in the spring table. | ||
| Aluminium barrier, 2 m section. Only in permitted configurations; length restrictions. | ||
| 24 red stickers to improve the boom's visibility. | ||
| XBA6 is a 6 m strip; XBA18 is 8 m long. Check the number and wiring against the power consumption at the LIGHT output. | ||
| 9 sections, 1 m each. Mechanical edge protection; does not replace a monitored safety edge. | ||
| 24 V rechargeable battery for operation during a power outage; the number of cycles depends on the charge level and equipment. | ||
| Motion and diagnostics indication via INTERNAL LIGHT. | ||
| Traffic control according to the INTERNAL LIGHT / OU4 setting. | ||
Photocells | Two-wire BlueBUS. After changing the wiring, perform Set 1. | |
Remote control | SM receiver and remote control with matching coding; if a receiver is already installed, check which remote-control family is stored. | |
Control board | Replacement board for the generation with a display and selector. The barrier already includes a controller; no additional external control unit is required. | |
Service and setup | BUS T4 interface for diagnostics and the service counter. | |
Solar power supply | Alternative power source instead of mains power. Do not connect 230 V at the same time with this wiring configuration. |
Installing the cabinet and boom
Disconnect the mains and backup battery before starting work. Check that the base is solid, drainage is adequate, there is room for the full boom, and the manual release is safely accessible.
Foundation plate and anchoring
If the existing foundation is suitable, mark four holes to match the cabinet and select anchors appropriate for the substrate. For a new foundation, prepare conduits, the four supplied anchor bolts, and a level foundation plate positioned parallel to the boom.
| Substrate check | Requirement |
|---|---|
| Concrete foundation | Reinforced concrete, at least 0.15 m thick and with a volume greater than 0.2 m³. Determine the foundation dimensions according to local conditions. |
| Concrete anchors | 4 anchors with 12 MA (M12) bolts, each with a tensile resistance of at least approximately 3.9 kN. |
| Other load-bearing material | Check that the substrate and all four anchor points can withstand a load of at least approximately 9.8 kN. |
| Installation | Keep the plate level with the surface; secure the cabinet only after the concrete has fully cured. |
Attaching and assembling the boom
For a two-piece boom, the shorter section goes next to the barrier cabinet. Insert the specified reinforcement insert into its end near the bracket: 300 mm for M7BAR. This insert is not the XBA9 connector that joins the two boom sections.
- Insert the two specified pins into the output shaft. Fit the bracket in the position for a vertical boom, and secure it with bolts and spring washers.
- Fit the cover onto the bracket with six screws; leave them loose for now.
- Insert the supplied connector insert into the end of the correct aluminum boom and secure it with a screw.
- Insert the protective rubber strip into the grooves with the appropriate connectors, then fit the end cap and rubber-strip end caps.
- Slide the complete boom fully into the bracket and tighten all six screws securely.
- Install the selected accessories, then complete the spring adjustment, balancing, and setup.
Joining the two sections using XBA9
- Slide the XBA9 connector into the open ends of both sections. The holes in the booms and connector must line up.
- The connector's three expansion screws should be loosened evenly as shown. This expands the mechanism and locks the connector inside the booms; it is not a standard process of tightening a fastening screw.
- Check that the joint is secure and has no play. Complete the balancing and tests only after assembling the boom and fitting its accessories.
Left- or right-hand barrier installation
The spring-hinge side must match the direction selector position on the board. RH/DX is for the spring on the right-hand side of the balancing lever, LH/SX for the spring on the left-hand side. A technician must change the mechanical configuration with the spring safely released; switching the selector without changing the mechanics is not sufficient.
Spring attachment and boom balancing
Select according to the exact model, actual length, and all installed accessories. The upper attachment is marked with the letter A or B, and the lower one with the number 1, 2, or 3. Use the lever holes marked for M7BAR. For the opposite closing direction, use the corresponding holes on the other side of the lever.
For the maximum-length boom with protective rubber, or with rubber and lights, use section A of the original table: M7BAR, 7.33 m = B / 2. For shorter booms and additional accessories, use section B.
Accessory indices for section B
| Boom accessories | Index |
|---|---|
| XBA13 protective rubber | 0 |
| XBA4/XBA6/XBA18 protective rubber with lights | 1 |
| WA12 | 4 with standalone XBA5 5.15 m; 3 with 5.00, 6.33, and 7.33 m |
| WA13 | 2 with standalone XBA5 5.15 m; 1 with 5.00 and 6.33 m; not permitted with 7.33 m |
Add the corresponding index for each accessory used. The “rubber” and “rubber with lights” rows are alternatives and must not be added together. Each additional accessory increases the load; the total and the number of items must remain within the permitted range for the configuration concerned. A dash indicates a combination that is not permitted.
| Exact arm configuration | Mounting based on the total index |
|---|---|
| XBA5, 5.15 m | 0–2: A / 2 3–5: A / 2 6–7: A / 3 |
| 2 × XBA15 shortened to 5.00 m | 0–2: A / 2 3–5: A / 3 |
| 2 × XBA15, 6.33 m | 0–2: B / 1 3–5: B / 2 |
| XBA15 + XBA14, 7.33 m | 3–4: B / 3 5–6: B / 2 Rubber or rubber with lights: section A, B / 2. WA13 is not permitted. |
Use the positions shown only with the same depicted bracket and spring arrangement. For a different mechanical design, follow the instructions supplied with the specific barrier; do not interchange hole positions between designs.
If the table does not cover the length, equipment, or resulting total, do not guess the mounting position. Before repositioning the spring, a technician must secure the arm and safely release the spring preload. Do not remove the arm from the bracket while the spring is under load.
Balance check at 45°, 20°, and 70°
- Disconnect the mains and the battery. Hold the arm securely, release the gearbox, and set it to approximately 45°.
- If the arm rises, reduce the preload by turning spring A clockwise. If it falls, increase the preload by turning it counterclockwise.
- Repeat the check at approximately 20° and 70°. The arm must not move significantly on its own or accelerate into a fall.
- Secure the spring against rotation using nut B as shown; check that it is firmly secured.
- Engage the gearbox lock when finished.
With the motor released, the force required to move the arm manually, when opening or closing it in any position, must not exceed approximately 45 N. This is the maximum permitted imbalance, not the adjustment target. Measure the force perpendicular to the arm, 1 m from the axis of rotation; this does not determine the impact force of the powered arm.
Mechanical stops
After releasing the lock, manually move the arm through its full travel. Use the stop screws to set the horizontal closed and vertical open positions, then tighten the locknuts. Then carry out Set 2 position learning. Electronic position learning does not replace correctly adjusted mechanical stops.
Wiring and power separation
Connect the 230 V mains cable to the L/N mains terminal block and the protective conductor as specified in the original installation. Secure the cable with a cable gland and strain relief. Do not apply 230 V to the command inputs or BlueBUS. Do not interchange the motor and accessory circuits.
| Cable | Cross-section and length |
|---|---|
| 230 V mains | 3 × 1.5 mm² up to 30 m; for longer runs, use 3 × 2.5 mm² and suitable grounding. |
| BlueBUS | 2 × 0.5 mm² up to 20 m; use 2 × 1 mm² for runs up to 40 m. |
| Key switch | 2 cables, each 2 × 0.25 mm², up to 30 m; these can be replaced with one 4 × 0.5 mm² cable. |
| OPEN / CLOSE | 2 × 0.25 mm² up to 30 m for each input. |
| Flashing light / indicator | 2 × 0.5 mm² up to 30 m; the device voltage must match the output setting. |
| Master–Slave | 2 × 1 mm² up to 20 m. |
| Antenna | RG58 coaxial cable, maximum 15 m; recommended length under 5 m. |
BCU1 R10 control unit: diagram and terminals
Disconnect the mains and the battery before wiring. The terminal blocks are removable; connect the wires according to the markings on the board itself. The following diagram is for a controller with a display and rotary selector.
The mains supply must have protective earth (PE) and a suitable device for complete disconnection from the mains. When connecting 230 V, check the protective devices. Mains voltage must not reach the command or accessory terminals.
| Terminal / connector | What to connect here |
|---|---|
| FLASH | Flashing light, standard 12 V, max. 21 W. OU2 changes both the function and voltage; check the current setting before connecting. |
| LIGHT | Arm lights, standard 24 V circuit, max. 10 W; OU1 function. |
| OGI | Barrier indicator, 24 V, max. 10 W; its operation is determined by OU3. |
| BlueBUS | Two-wire power supply and communication for compatible accessories, with no polarity requirement. |
| STOP | NO, NC, or 8.2 kΩ; the type is detected during learning. A subsequent change of state stops the operation. |
| SbS / OPEN / CLOSE | Voltage-free NO switching contacts for step-by-step operation, opening, or closing. The In1–In3 assignments can be changed. |
| HP SbS | High-priority NO command input; default In4 = 6. |
| LOOP1 / LOOP2 | Connection for the output of an inductive loop detector. The loop itself must not be connected directly as a command contact. |
| MASTER–SLAVE | Communication between two opposing barriers; maintain connections 1–1 and 2–2. |
| SAFETY | NC safety contact for the breakaway arm, depending on the equipment used. |
| INTERNAL LIGHT | Dedicated connector for XBA7 or XBA8, OU4 function. |
| ANTENNA / SM | Coaxial antenna and separate socket for a compatible receiver. |
BlueBUS photocells and STOP input
EPMB photocells are connected in parallel to the two BlueBUS wires. The TX and RX units in a pair must have the same address; another pair requires a different one. For safety protection across the passage, use the FOTO, FOTO II, FOTO 1, or FOTO 1 II addresses according to their position and function. FA1/FA2 are command addresses for opening and do not replace the safety function of the photocells.
After adding or removing photocells, or changing the STOP input, perform Set 1 and a new safety-function test. Do not bypass a fault to disable STOP; the connection of multiple safety devices must comply with their type and monitoring requirements.
For the BCU1 R10 configuration shown, the maximum BlueBUS load is 10 BlueBUS units. Calculate the consumption according to each device's instructions; the number of units is not necessarily the same as the number of physical devices.
Lights, beacon and traffic light
XBA6 / XBA18 are fitted into the boom groove according to their instructions. XBA7 and XBA8 are connected to INTERNAL LIGHT. Before changing any OU1–OU4 setting, check the output voltage and maximum power rating. Do not confuse the traffic-light connector with the terminal for a standard external beacon.
Power supply for additional 24 V accessories
Separate output 24 V DC for auxiliary devices has a tolerance of −30% to +10% and a maximum available current of 500 mA total. Add up the current draw of all devices powered this way. On its two-pole terminal block, marked − + 24 V when viewed as shown in the image below, the left terminal is negative (−) and the right terminal is positive (+).
| 24 V auxiliary output terminal | Accessory power supply wire |
|---|---|
| Left: − | Negative (−), marked 0 V or GND on the device. |
| Right: + | Positive (+), marked +24 V on the device. |
This marking applies to the separate 24 V output shown below. BlueBUS photocells are connected without regard to polarity to their dedicated BlueBUS terminals. The SbS, OPEN, CLOSE and HP SbS command inputs use potential-free contacts; do not apply external power to them.
Initial start-up and setup
Before switching on, the boom must be installed with all its equipment, balanced and secured. Check the end stops, direction selector, safety devices and clear passage. After connecting the mains supply, the display and photocell LEDs should light up; with the default settings, the beacon should remain off when the barrier is not moving.
1. Set → 1: BlueBUS and STOP setup
- Turn the selector until you find Set.
- Briefly press the selector and choose value 1 then press again to confirm.
- The control unit detects the connected devices and the type of STOP input. Perform the setup even if no accessories are connected.
If error E01 persists, check the wiring and compatibility; do not simply repeat the setup without fixing the cause.
2. Set → 2: mechanical position setup
- Unlock the motor, move the boom manually to approximately 45° and lock the gearbox.
- On the selector, choose Set → 2 and confirm.
- Allow the control unit to complete the full travel setup. The balancing lever must reach the set mechanical end stops.
- If it does not reach the end stops, stop the setup by pressing the selector, adjust the mechanism and start again. After each interruption, repeat the procedure from the beginning.
Menu 8.8.8. starts the quick combined setup of devices and positions. With this option too, first move the boom manually to approximately 45° and lock the gearbox. Keep the movement area clear. Device or position setup does not program the remote-control buttons.
3. Checking movement and safety
Use the OPEN and CLOSE buttons to run several complete cycles. The boom should slow down before reaching the end stops; it must not catch, drop suddenly or vibrate excessively. Test each pair of photocells, the STOP input, manual release, power failure and any Master–Slave setup.
Also check the risk of the boom lifting a person: the test uses a 20 kg load at the midpoint of the boom and, when opening, the boom must not rise more than 50 cm above the closed position. Measure impact force according to the requirements of the specific installation; photocells and reducing the force do not, on their own, replace a full risk assessment.
Programming the BCU1 R10 using the rotary selector
The control unit is configured using a rotary selector and a three-digit display. Before making changes, note the original value; changes to force, speed and safety functions require a new barrier test.
- Turn the selector in either direction to choose the parameter code.
- Press it briefly and release. The stored value appears; the display remains steadily lit.
- Turn the selector to choose a new value. The display flashes while a value is being selected.
- Press and release to confirm the value. The control unit returns to parameter selection.
Selecting ESC exits without saving the change. The display --- indicates a configuration set via OVIEW; it is not another selectable value. In the tables, the confirmed factory setting is shown in bold; the actual control board may have values changed during installation.
Operating functions F01–F09
| Parameter and purpose | Values and behavior |
|---|---|
| F01 – Automatic closing Applies after fully opening. | OFF – semi-automatic operation: closing by command (factory setting) On – closes after time t01 |
| F02 – Closing after photocell activation After the selected safety device is cleared, it starts counting time t10. | OFF – disabled (factory setting) 1 – open only until the photocell is cleared: activation stops movement; once cleared, t10 starts and the gate closes 2 – open fully: activation triggers full opening; a new opening command during t10 cancels the subsequent closing 3 – open fully 2: same as value 2, but a new opening command during t10 does not cancel the subsequent closing |
| F03 – Device for F02 | 1 – photocells and loops configured as photocells (factory setting) 2 – photocells only 3 – loops configured as photocells only |
| F04 – Close when power is restored Before enabling this function, assess the safety of automatic movement after a power failure. | OFF – disabled (factory setting) 1 – if the barrier arm is not closed, it flashes for t09 after power is restored, then closes 2 – resumes automatic closing if the pause countdown was in progress before the power failure |
| F05 – Standby Activates after time t04; a new command resumes operation. | OFF – disabled (factory setting) 1 – switches off the display, BlueBUS, outputs, and some internal circuits 2 – switches off BlueBUS 4 – when powered by a battery, automatically enters full standby |
| F06 – Starting force | OFF – disabled (factory setting) On – when starting from the open or closed position, briefly applies maximum power to overcome static friction |
| F07 – Emergency opening Requires a connected, working battery. | OFF – disabled (factory setting) On – automatically opens the barrier arm in the event of a mains power failure |
| F09 – Master / Slave | OFF – Master barrier (factory setting) On – Slave barrier; see Master–Slave procedure |
Times, speeds, force, and input functions
| Parameter and purpose | Available values |
|---|---|
| 8.8.8. – Quick programming | Starts the BlueBUS, STOP, and position programming sequence. First, meet the start-up requirements. |
| Set – Programming | 1 – BlueBUS and STOP devices 2 – open and closed positions |
| Prn – Program | 000 – basic program (factory setting) 001 / 002 / 003 – reserved customised programs; not normally used |
| t01 – Pause before closing Applies when F01 = On. | 0–250 s Factory setting: 20 s |
| t02 – Pre-flashing before opening Time between the beacon switching on and opening starting. | 0–5.0 s Factory setting: 0 s |
| t03 – Pre-flashing before closing Time between the beacon switching on and closing starting. | 0–5.0 s Factory setting: 0 s |
| t04 – Standby delay Time from the end of a manoeuvre until enabled F05 activates. | 0–60 s Factory setting: 60 s |
| t06 – Electromagnet delay After the locking electromagnet is disconnected, it waits before opening. Used only when an electromagnet is installed and the output is configured accordingly. | 0–3.0 s Factory setting: 0.2 s |
| t07 – Auxiliary light duration How long the output configured as an auxiliary light stays on. | 0–250 s Factory setting: 60 s |
| t09 – Pre-flashing after power is restored Used by function F04. | 0–20 s Factory setting: 5 s |
| t10 – Closing after photocell activation Time after the device is cleared when F02 is enabled. | 0–250 s Factory setting: 5 s |
| SPO – Opening speed | 1 – slowest 2 – level 2 3 – level 3 4 – fastest (factory setting) |
| SPC – Closing speed | 1 – slowest 2 – level 2 3 – level 3 4 – fastest (factory setting) |
| SLO – Opening slowdown | 1 – slowest speed 2 – medium speed (factory setting) 3 – fastest speed |
| SLC – Closing slowdown | 1 – slowest speed 2 – medium speed (factory setting) 3 – fastest speed |
| PLO – Opening slowdown position Distance between the end position and the start of slowdown. | 1 – 0° (factory setting) 2 – approx. 10° 3 – approx. 20° |
| PLC – Closing slowdown position Distance between the end position and the start of slowdown. | 1 – 0° (factory setting) 2 – approx. 10° 3 – approx. 20° |
| FrO – Opening force Does not replace mechanical balancing. | 1 – lowest 2 – level 2 3 – medium (factory setting) 4 – level 4 5 – level 5 6 – highest |
| FrC – Closing force Does not replace mechanical balancing. | 1 – lowest 2 – level 2 3 – medium (factory setting) 4 – level 4 5 – level 5 6 – highest |
| tF – Force limit intervention time A higher value increases the time before an obstacle is detected. | 3–32, each unit = 30 ms Range: 90–960 ms Factory setting: 3 = 90 ms |
| In1 – SbS input | Available codes: 0, 1, 3, 4, 6, 7, 8, 11, 12, 16, 19, 20, 21, 22, 25, 26, 27, 28, 29, 30. Factory setting: 1 Meaning of input codes; for In2, code 25 controls Master only. |
| In2 – OPEN input | Available codes: 0, 1, 3, 4, 6, 7, 8, 11, 12, 16, 19, 20, 21, 22, 25, 26, 27, 28, 29, 30. Factory setting: 3 Meaning of input codes; for In2, code 25 controls Master only. |
| In3 – CLOSE input | Available codes: 0, 1, 3, 4, 6, 7, 8, 11, 12, 16, 19, 20, 21, 22, 25, 26, 27, 28, 29, 30. Factory setting: 4 Meaning of input codes; for In2, code 25 controls Master only. |
| In4 – HP SbS input | Available codes: 0, 1, 3, 4, 6, 7, 8, 11, 12, 16, 19, 20, 21, 22, 25, 26, 27, 28, 29, 30. Factory setting: 6 Meaning of input codes; for In2, code 25 controls Master only. |
| SE1 – Step-by-step sequence | 1 – industrial mode: semi-automatic opening, closing while the command is held 2 – open – stop – close – stop 3 – open – stop – close – open 5 – residential step-by-step mode (factory setting) 6 – hold-to-run control |
| SE3 – OPEN sequence | 1 – open – stop – open 2 – residential opening mode (factory setting) 3 – opening while the command is held |
| SE4 – CLOSE sequence | 1 – close – stop – close 2 – residential closing mode (factory setting) 3 – closing while the command is held |
| SE5 – Photocell function during closing | 1 – stop and reverse to open (factory setting) 4 – stop temporarily; open when the photocell is cleared 5 – stop temporarily; close when the photocell is cleared |
| SE6 – STOP during opening | 1 – stop immediately 2 – stop and briefly reverse to close (factory setting) |
| SE7 – STOP during closing | 1 – stop immediately 2 – stop and briefly reverse to open (factory setting) |
| SE8 – Obstacle during opening | 2 – stop and briefly reverse to close (factory setting) 3 – stop and fully reverse to close |
| SE9 – Obstacle during closing | 2 – stop and briefly reverse to open 3 – stop and fully reverse to open (factory setting) |
| LO1 – LOOP1 function | 1 – open – open, NO contact (factory setting) 2 – close – close, NO contact 4 – photocell, NC contact |
| LO2 – LOOP2 function | 1 – open – open, NO contact 2 – close – close, NO contact (factory setting) 4 – photocell, NC contact |
In hold-to-run mode, the arm moves only while the contact is active. Residential mode prevents opening from being interrupted by further commands; test its behavior in your own setup before use. F02 determines whether the gate closes after the safety device is cleared; SE5 determines the arm's response when triggered during closing—the settings are not interchangeable.
Meaning of In1–In4 command codes
| Code | Command |
|---|---|
| 0 | No command. |
| 1 | Step-by-step operation according to SE1. |
| 3 | Opening according to SE3. |
| 4 | Closing according to SE4. |
| 6 | High-priority step-by-step operation, effective even when software-locked. |
| 7 | Open and software-lock. |
| 8 | Close and software-lock. |
| 11 | Switch on the timed auxiliary light; it switches off after the set time. |
| 12 | Switch the auxiliary light on/off; the set time also applies. |
| 16 | Photocell. |
| 19 | Software-unlock and open. |
| 20 | Software-unlock and close. |
| 21 | Enable opening by BlueBUS command photocells. |
| 22 | Disable opening by BlueBUS command photocells. |
| 25 | Step-by-step operation of Master and Slave; on In2, controls Master only. Verify the assignment by testing both arms before operation. |
| 26 | Open both Master and Slave. |
| 27 | Close both Master and Slave. |
| 28 | Step-by-step operation of Slave only. |
| 29 | Open Slave only. |
| 30 | Close Slave only. |
OU1–OU4 outputs and indicators
Changing the function may also change the output voltage. External 24 V functions are limited to 10 W per output; the 12 V warning light on FLASH is limited to 21 W. Always check the device, voltage and power consumption before connecting. INTERNAL LIGHT is a connector intended for the dedicated XBA7/XBA8 module.
| Output | Code and function |
|---|---|
| OU1 – LIGHT | 0 – 24 V warning light 1 – OGI indicator 2 – barrier closed 3 – barrier open 4 – barrier arm flashing light (factory setting) 5 – maintenance indicator 6 – auxiliary light 8 – red traffic light 9 – green traffic light 10 – radio channel 1 11 – radio channel 2 12 – radio channel 3 13 – radio channel 4 14 – locking electromagnet |
| OU2 – FLASH | 0 – 24 V warning light 1 – 12 V warning light (factory setting) 2 – OGI indicator 3 – barrier closed 4 – barrier open 5 – barrier arm flashing light 6 – maintenance indicator 7 – auxiliary light 9 – red traffic light 10 – green traffic light 11 – radio channel 1 12 – radio channel 2 13 – radio channel 3 14 – radio channel 4 15 – locking electromagnet |
| OU3 – OGI | 0 – 24 V warning light 1 – OGI indicator 2 – barrier closed (factory setting) 3 – barrier open 4 – barrier arm flashing light 5 – maintenance indicator 6 – auxiliary light 8 – red traffic light 9 – green traffic light 10 – radio channel 1 11 – radio channel 2 12 – radio channel 3 13 – radio channel 4 14 – locking electromagnet |
| OU4 – INTERNAL LIGHT | 0 – warning light (factory setting) 1 – OGI indicator 2 – barrier closed 3 – barrier open 4 – auxiliary light 5 – red traffic light 6 – green traffic light 7 – one-way traffic light 8 – alternating one-way traffic light 9 – pedestrian traffic light |
| Signal mode | Description |
|---|---|
| Warning light | Flashes during operation: on for 0.5 s / off for 0.5 s. |
| OGI | Closed: off; opening: slow flashing; closing: fast flashing; open: on. |
| Barrier closed / open | On only at the selected end position. |
| Barrier arm flashing light | Flashes every 0.5 s, even when the barrier arm is stationary. |
| Maintenance | Below 80% of the set count: on for 2 s at the start of opening. From 80% to 100%: flashes during operation. Above 100%: flashes continuously. |
| Auxiliary light | On while moving and afterwards until t07 expires. |
| Red traffic light | Flashes slowly while closing, stays on when closed, and is otherwise off. |
| Green traffic light | Flashes slowly while opening, stays on when open, and is otherwise off. |
| Radio channels | The command for the corresponding channel switches the output on; the command intended for the control unit is ignored. |
| Locking electromagnet | Active when closed; switches off before opening, and the unit waits for time t06. |
| OU4 = 7 | Green when the barrier arm is open, red in all other states. |
| OU4 = 8 | For the inside, use In2 or LOOP1 set to open; for the outside, use In3 or LOOP2 set to open. Green is assigned to the side that issued the command, with red lit on the opposite side. When closed or closing, both sides are red. |
| OU4 = 9 | When closed, green on the inside and red on the outside; when open, the opposite. In intermediate positions, both sides are red. |
Counters, versions and service data
| Menu | Use |
|---|---|
| MnP – Set number of operations | Press to display in sequence: a = units, b = thousands, c = millions. Used for maintenance signalling. |
| MnE – Number of operations performed | Press to display in sequence: t = units, u = thousands, v = millions. |
| ErS – Reset | 1 – devices; 2 – positions; 3 – function values; 5 – everything. Procedure and subsequent learning. |
| Fir – Firmware version | Press twice to display two three-digit identification parts. |
| Hdr – Hardware version | Press three times to display three three-digit identification parts. |
| din – Input diagnostics | Input and display statuses. |
Resetting the board does not reset the service counter. Reset it using OVIEW only after maintenance has been carried out and recorded.
Two opposing barriers: Master–Slave
Two complete barriers can be synchronised. Each has its own motor, control unit and power supply; they are not connected like two motors on one board. Connect the communication terminals 1–1 and 2–2 using 2 × 1 mm² cable, up to 20 m long.
- Complete installation, direction, balancing and electrical wiring on both barriers.
- On the Slave barrier, perform Set 1 and Set 2, set its speeds, deceleration and force, then set F09 = On.
- On the Master barrier, perform Set 1 and Set 2. Until then, the Slave may report communication error E05.
- Issue a command from the Master unit and check the movement of both barrier arms and the safety devices.
Shared BlueBUS devices and the receiver belong on the Master. The Slave's own SbS/OPEN/CLOSE commands can operate only its own barrier arm. Speed, deceleration, deceleration position and force are set separately for each barrier. For backup power, each barrier needs its own PS224.
Remote controls and backup power
Receiver and remote controls
The control board has an SM slot for a compatible receiver. Current selection OXIBD allows you to use compatible remote controls, such as ON2E. Connect the receiver with both the mains power and battery disconnected. Store and delete remote controls according to the specific receiver instructions; resetting the control board does not replace the receiver's radio programming procedure.
PS224 during a power outage
PS224 is connected only after installation and programming are complete: disconnect the mains, install the battery and connect the specified cable to the backup power connector; then restore the mains supply. Mode F05 = 4 can reduce power consumption when running on battery power. The F07 = On function commands the barrier to open during a mains failure if a battery is connected; it is not enabled by default.
Solemyo SYKCE30 is a different power supply option. When using the Solemyo system, the barrier must not be connected to the 230 V mains at the same time. Assess the power source capacity based on the number of operating cycles and the accessories installed.
Troubleshooting
First, check the code on the display or count the short flashes. The diagnostic sequence repeats after a pause of about 1 s; normal flashing during movement is not an error code.
When the barrier does not respond or moves incorrectly
| Symptom | What to check |
|---|---|
| The remote control does not respond and its LED is off | Check the remote control battery. |
| The remote control LED is on, but the barrier does not respond | Check that the remote control is programmed and compatible with the installed receiver; receiver and remote control. |
| The display is off and no commands work | Check the power supply and fuses F1/F2. Replace a fuse only after identifying the cause, using the same type and rating; never bypass a fuse. |
| A command is issued, but the operating cycle does not start | For a wired command, check the LED for the corresponding input. If the warning light indicates a fault, use the code table below. |
| The arm immediately reverses direction or moves unusually slowly | First check the balance, free movement, stops and limit switches. If the control board does not detect the end position, check the switches and position learning. |
| The arm moves in the opposite direction | Check the spring side and direction switch. Do not swap the wires at random. |
| Code / signal | What to check |
|---|---|
| E01 / 1 flash | BlueBUS/STOP devices changed or not learned. Check the wiring, then run Set 1. |
| E02 | Positions not learned; after checking the stops and balance, run Set 2. |
| E03 | Limit switches reversed; check their direction and electrical connections. |
| E04 | Encoder signal missing; check the sensor connector and cable. |
| E05 | Communication error Master–Slave; check the polarity and run position learning for both barriers. |
| E06 / 5 flashes | Parameter memory error. Disconnect and restore power to all sources, then try again; if the issue persists, servicing is required, or perform a full reset and learn the positions again. |
| E07 / 7 flashes | Internal electronics error. Disconnect all power sources; if the fault recurs, arrange servicing. |
| E08 | Barrier type configuration; check the control board's factory settings. |
| E09 / 9 flashes | Software lockout. Enter the specified unlock command, or HP SbS; this is not mechanical release using a key. |
| E10 | Missing NC safety contact or limit switch; check SAFETY and the switches. |
| E11 | BlueBUS short circuit. With the power disconnected, check the wiring and devices. After fixing the cause, restore power, issue a command and wait 40 s. If the fault recurs, servicing is required. |
| I02 / 2 flashes | Photocell active. Remove the obstruction, clean the optics and check the alignment. |
| I03 / 3 flashes | Force limit triggered. First check the balance, friction and stops. Do not increase the force to compensate for a mechanical fault. |
| I04 / 4 flashes | STOP activated. Find the cause in the connected device; do not bypass the safety input. |
LEDs and din mode
STOP is on when the input is normally enabled; if it goes off, the input has been triggered. The SbS, OPEN, CLOSE and HP SbS LEDs are on when a command is active. FC1/FC2 status depends on the RH/LH switch: with RH, FC1 goes off in the closed position and FC2 in the open position; with LH, the opposite applies.
Display codes and warning-light flash counts are numbered differently. For example E06 means five flashes; sequences of six and eight flashes have no assigned function in this configuration.
Menu din shows the inputs using the display’s three-digit segments. The A to G labels and the dp decimal point are shown in the image. For FC1/FC2, the open and closed positions are governed by the RH/LH setting given above.
| Digit | Segment and meaning |
|---|---|
| First | A1 – LOOP1 B1 – CLOSE C1 – HP SbS D1 – LOOP2 E1 – OPEN F1 – SbS G1 – unused dp1 – flashes once per second while the board is running |
| Second | A2 – FC1 B2 – CLOSE button on the board C2 – RH direction D2 – battery power E2 – LH direction F2 – OPEN button on the board G2 – FC2 dp2 – motor sensor input A |
| Third | A3 – opening photocell FA1 B3 – FOTO active C3 – FOTO II active D3 – opening photocell FA2 E3 – FOTO 1 active F3 – FOTO 1 II active G3 – Master has detected Slave dp3 – motor sensor input B |
With the motor stopped, dp2/dp3 may be lit or unlit depending on the sensor position; they flash while the motor is moving. Correct the incorrect direction in the mechanics and switch, not by swapping random wires.
Clearing settings and starting over
Select ErS, press, select the required value, and confirm. 1 deletes learned devices, 2 positions, 3 function values, 5 all control unit data. After a full reset, repeat Set 1, Set 2, setup, and the safety tests.
Control board reset does not reset the number of completed manoeuvres. Reset the service counter only after maintenance has actually been performed, via OVIEW. Deleting transmitters is part of the procedure for the specific receiver.
Manual arm release
In the event of a power failure, malfunction, or installation work, stop operation, disconnect the power supply, and secure the area. Hold the arm; an incorrectly balanced arm may move on its own.
- Insert the release key and turn it 180° to the left or right.
- Move the arm manually to the required position.
- To restore motorised operation, return the key to its original position and remove it. Check that the mechanism is locked and that control has been safely restored.
Maintenance and service life
For an existing installation with BCU1 R10, schedule a professional inspection no later than after 6 months or 20,000 manoeuvres, whichever comes first. Under intensive use, the cycle limit may be reached much sooner. Check the balance after changing the arm equipment as well.
Disconnect all power sources and check the secure connection between the two arm sections, the XBA9 coupling’s expansion bolts, corrosion, anchoring, screws and spring attachment, shaft play, the condition of the arm, and the operation of the release mechanism. After restoring power, repeat the safety device and force tests. Record servicing and any spring replacement in the maintenance log.
Factors affecting the estimated service life
| Characteristics of the complete automation system | Index | Service life graph |
|---|---|---|
| Speed, level 3 | 15% | |
| Speed, level 2 | 10% | |
| Photocell activations in more than 10% of manoeuvres | 15% | |
| STOP activations in more than 10% of manoeuvres | 15% | |
| WA12 mobile support | 10% in an approved configuration | |
| Salt in the environment | 10% | |
| Dust / sand | 5% | |
| Under-barrier rail | 5% in an approved configuration | |
| Temperature above 40 °C or below 0 °C | 5% | |
| FrO / FrC force setting | Level 4: 5% Level 5: range 5–10% Level 6: 10% |
Speed levels 2 and 3 are alternatives; add only the level in use. No index is specified for level 4, so do not estimate the number of cycles for it. Add the indices for the other applicable factors. Find the total on the graph’s horizontal axis and read the estimated number of cycles from the vertical axis. For force level 5, the estimate is a range; do not estimate the number of cycles outside the graph’s range. The estimate assumes correct installation and regular maintenance; it does not guarantee a number of cycles or justify postponing service.
Technical specifications of the NICE M7BAR barrier
| Parameter | Value |
|---|---|
| Model | NICE M7BAR – without boom |
| Type | Electromechanical barrier with a 24 V DC motor and integrated controller |
| Control unit | BCU1 R10 (XBA3 R10) |
| Power supply | 230 V AC, 50/60 Hz |
| Motor voltage | 24 V DC |
| Current consumption | 1.1 A |
| Maximum starting power | 110 W |
| Power consumption at rated torque | 40 W |
| Operating time | 6–10 s |
| Starting torque | 300 Nm |
| Rated torque | 90 Nm |
| Max. frequency at rated torque | 200 cycles/h |
| Clear opening | 5–7 m |
| Protection rating | IP54 |
| Operating temperature | −20 to +55 °C |
| Cabinet dimensions | 400 × 299 × 1 215 mm (width × depth × height) |
| Weight | 85 kg |
| Insulation class | I |
| Backup power supply | PS224 |
| Solar power supply | Solemyo SYKCE30 |
The specifications apply at a reference temperature of approximately 20 °C. Consider them together with the arm length, equipment and balancing. For a different operator or control unit version, check the movement time and available settings against the identification label on the device.
The drawing also shows protruding parts and the exact dimensions of 298.5 and 1,219.5 mm. Follow the drawing when anchoring and positioning; do not rely solely on the rounded cabinet dimensions in the table.