NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range


Product availability: Unavailable

We’ll be happy to help you choose a replacement. Feel free to contact us.


NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range

Description of NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range

Available replacement!
The NICE Moonclever MC824H control unit has been replaced by a newer model - NICE Moonclever MC824HR10.

Quick navigation on this page:
Compatible accessories… Manual… Installation and assembly…, Wiring…
Connecting the control unit… - to the power supply…, of accessories…, wiring diagram…
Photocells… Radio receiver… Evaluating the drive accessories…
Evaluating gate leaf movement… Programming the drive control unit… Connecting external devices…
Troubleshooting - by type…, diagnostics using the warning light…, diagnostics using LEDs…
Special functions… Installing the backup battery… Technical specifications…


NICE Moonclever MC824H is a control unit for automating single-leaf, or double-leaf gates. Drives compatible with it must have a 24Vdc and a magnetic encoder (a rotary motor speed sensor for precise detection of the gate leaf position).

Compatible only with the specifically listed swing gate drives:

  • Metro (ME3024)
  • Moby (MB4024, MB5024)
  • Hyppo (HY7024, HY7124)
  • Toona (TO4024, TO5024, TO7024)
  • X-Metro (XME2124)
  • Big-Metro (BM5024)
  • Metroelite
  • Wingoelite

NICE Moonclever BoxThe MC824H control unit includes the MCA1 control board, housed in a dedicated plastic enclosure Moonclever. Includes an SM connector for connecting radio signal receiver (SMXI, OXI, ...) from remote controls (Flor, Era Flor, Era One, Era Inti, ...).

Supports BlueBUS, which allows accessories to be connected easily (photocells, warning light, card readers, key switches, etc.) using just a two-core cable, with no need to observe polarity.

Thanks to 24V it is also compatible with the NICE Solemyo solar power system, which provides power even in locations without access to mains electricity. It is also possible to power the control unit using the NICE PS324 backup battery, which can operate the swing gate through several opening and closing cycles for a few hours after a power cut. When standby mode is enabled, the control unit with a connected control signal receiver uses only 2W (when powered by a PS324 battery, or the Solemyo solar power system, consumption is just 0.1W).

Supports NICE Opera technology. Diagnostics using warning light.

After detecting the gate leaf length, the acceleration and deceleration intervals for opening and closing are set automatically. You can also set the force, speed, pedestrian opening etc. See Control unit programming. Obstacle detection throughout the gate leaf's movement ensures safe operation of the motors.

NICE Moonclever MC824H control unit is suitable for the climate in Slovakia and meets all European safety standards.

Accessories compatible with the NICE Moonclever MC824H control unit

We recommend purchasing compatible optional accessories for the control unit:

What Why Type
Warning light The warning light flashes to indicate gate movement—ideal for exits with limited visibility. It also has a built-in antenna for greater remote-control range. - Lucy (LUCYB)
- Moonlight (MLBT)
Photocells They detect obstacles while the gate is closing and stop it moving, preventing it from hitting a car or a person. - MoonBUS (MOFB)
Transmitter

For remote control of the gate.

- FloR (Flo2R-s, Flo4R-s)
- Era One (ON2E, ON4E)
- Era Flor (Flo2RE, Flo4RE)
- Era Inti (INTI2)

Receiver Required for remote control of the gate. - OXI
- SMXI
Antenna For improved remote-control range. - built into the warning light LUCYB, MLBT
- ABFKIT antenna only, or ABF
Keypad If you forget your remote, or if many vehicles or people visit and you don't want to give everyone a remote or open the gate manually. - MOTXR

NICE Moonclever MC824H control unit manual

Download the NICE Moonclever MC824H control unit manual here:

NICE Moonclever MC824H control unit manual

Instructions for pairing, deleting, and saving a remote control to/from the memory of a NICE drive receiver

Installing the NICE Moonclever MC824H control unit

Installing the control unit in a standard mounting box Moonclever is mounted using four screws:

Installing the NICE MC824H control unit Installing the NICE MC824H control unit
1. Unscrew the plastic cover screws 2. Secure the control unit box using four wall plugs

 

Wiring

Typical (optional) wiring configuration for the drive control unit and accessories is as follows:

NICE MC824H wiring configuration

List of accessories

  1. MC824H control unit
  2. Swing gate operators
  3. Warning light with built-in antenna
  4. Photocells
  5. Digital keypad/Card reader/Key switch
  1. Photocells on post
  2. Gate opening stop
  3. Gate closing stop
  4. Electric lock

NICE MC824H wiring diagram

 

Wiring list

Purpose Type Max. length
A. Power supply 3×1.5mm2 30m; for longer runs, 3×2.5mm2 + grounding
B. Flashing light with antenna

2×0.5 mm2
1×coaxial cable

20 m
20 m (recommended length: less than 5 m)
C. Photocells 2×0.5 mm2 30 m; over 30 m, 2×1 mm2
D. Key switch 4×0.5 mm2 50 m (or 2 pcs. 2×0.5 mm2)
E. Operator power supply 3×1.5 mm2 10 m
F. Encoder 2×1.0 mm2 10 m
G. Electric lock 2×1.0 mm2 10 m

Wiring the NICE Moonclever MC824H control unit

Before connecting, disconnecting, or changing the wiring of the operator or any accessories, remember to disconnect the power supply, either at the circuit breaker, by removing the power supply fuse, or by disconnecting the backup battery. Wait until all the LEDs go out.

...to the mains

Power supply wiring for the NICE Moonclever MC824H operator

For the operator to function at a basic level, you only need to connect the mains power supply to the operator control unit power supply.

 

The wiring is simple:

L Live (brown)
I Earth (green)
N Neutral (blue)

 

 

...accessories

NICE MCA1 control unit unit NICE Moonclever MC824H provides the following inputs and outputs for accessories:

Input/output Description
AERIAL
(Antenna)
Input for the radio receiver antenna. The antenna is usually built into the warning light, for example: NICE LUCYB, NICE MLBT, or a separate external antenna can be used NICE ABFKIT.

FLASH
(Flashing light)

Output for one 12 V warning light NICE LUCYB (or NICE MLBT) with one 12 V, 21 W bulb

ELS

Output for 12 VAC, max. 15 VA electric lock
S.C.A.
(Indicator)
Output for indicator (24 V, 4 W). Its operation can be set by programming level II, parameter L4; see Level II programming, L4 – Indicator output.

BLUEBUS
(BlueBUS)

Input for connecting compatible devices in parallel using BlueBUS via a two-core cable that carries both the power supply and the communication signal.
STOP
(Stop)

Input for devices that stop gate movement. The following devices can be connected:

  • Any number of normally open devices connected in parallel
  • Any number of normally closed devices connected in series
  • Two devices with a constant resistance of 8.2 kΩ connected in parallel
  • Multiple devices with a constant resistance of 8.2 kΩ connected in a cascade, with a total resistance of 8.2 kΩ
  • A combination of three: a normally open device connected in parallel, a normally closed device connected in series, and a device with a constant resistance of 8.2 kΩ.

 

STEB-BY-STEP
(P.P., Step-by-step)

Input for devices that step through gate movement (see Step-by-step gate movement). Normally open devices (NO) can be connected.
OPEN
(Open)
Input for devices that control gate opening only (see Gate opening). Normally open devices (NO) can be connected.
CLOSE
(Close)
Input for devices that control gate closing only (see Gate closing). Normally open devices (NO) can be connected.
ENC1 Input for the encoder of operator M1 (terminals 1, 2); polarity does not need to be observed

Wiring the drives to NICE Moonclever MC824H

Wiring motors M1 and M2 and their encoders

ENC2 Input for the M2 drive encoder (terminals 4, 5); polarity does not matter
M1 Output for motor M1 (terminals 7, 8, 9)
M2 Output for motor M2 (terminals 10, 11, 12)

Control unit fuses

Coming soon

Standard wiring diagram:

Standard wiring diagram for the NICE Moonclever MC824H control unit

Drive photocells

Highly user-friendly BlueBUS technology allows power and control up to 7 pairs of photocells using a two-core cable.

WIRING MULTIPLE PAIRS OF PHOTOCELLS NICE MOFB TO THE DATA NETWORK NICE BLUEBUS

Position the photocells around the gate or door according to the example configurations for complete wiring, and set the jumpers according to the photocell jumper table NICE MOFB gate drive. To prevent interference between pairs positioned close to one another, be sure to follow these example configurations, and observe the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not matter):

Parallel wiring of NICE MOFB gate-drive photocells

Example photocell wiring configuration

Wiring a photocell for a swing gate

 

If you want the photocells to operate as gate openers (see FA1 and FA2 in the image), i.e. so that when a vehicle passes between their optical axes they open the gate, you need to break connection A on the transmitter TX and receiver RX, as shown:

Connection A on NICE MOFB photocells

NICE MOFB gate-drive photocell jumper table

Compartment in the NICE MOFB photocell for unused jumpers

Connecting multiple pairs of photocells to the BlueBUS system is done by setting different jumper combinations; each connected pair must have a unique jumper combination. Make sure that no two pairs in the same BlueBUS data network have the same combination. For each pair of photocells, set the jumper on both the transmitter TX and receiver RX to the same value. If the jumper type uses only one jumper, always store the other one in the unused compartment, as shown in the image on the left.

Photocell pair designation Jumper setting using a combination of jumpers
FOTO MOFB photocell jumper setting: FOTO
FOTO II MOFB photocell jumper setting: FOTO II
FOTO 1 MOFB photocell jumper setting: FOTO 1
FOTO 1 II MOFB photocell jumper setting: FOTO 1 II
FOTO 2 MOFB photocell jumper setting: FOTO 2
FOTO 2 II MOFB photocell jumper setting: FOTO 2 II

FOTO 3

WARNING: CONFIGURATION NOT ALLOWED!

MOFB photocell jumper setting: FOTO 3

FA1
(Break connection A
on the transmitter TX
and receiver RX)

MOFB photocell jumper setting: FA1

FA2
(Break connection A
on the transmitter TX
and receiver RX)

MOFB photocell jumper setting: FA2

 

If a photocell needs to be replaced for any reason, simply set the same jumper as the original one; there is no need to perform the device recognition procedure.

Radio receiver for drives

Drive radio receiver

NICE Moonclever MC824H control unit is supplied with the NICE MCA1 control unit, which provides an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted by from the remote controls, so it is essential for operating the sliding gate remotely remote control.

 

Recognition of connected drive devices

After connecting, disconnecting, or changing the wiring of any accessories on the BlueBUS inputs and STOP the accessory recognition procedure must be carried out accessory recognition phase. The drive will alert you that this procedure is required by flashing LEDs L1 and L2.

 
  1. Press the “Open” and “Stop/Set” buttons and hold them down
  2. Once L1 and L2begin flashing rapidly, release the buttons
  3. Wait a few seconds for the control unit to complete the device recognition process.
  4. If everything went well, the STOP LED should be lit and L1 and L2 should be off. Alternatively, L3 and L4may start flashing if you have not yet completed the gate leaf movement recognition phase.

 

Gate leaf movement recognition (automatic mode)

For the gate to move correctly (in particular, to calculate the acceleration and deceleration distances and partial opening), the control unit must determine the gate leaf opening arc length itself. During this procedure, the drive moves the gate leaves from one end stop to the other and determines the gate opening travel distance. There are also alternative manual and combined procedures, which you can find in the manual.

 
  1. Press the “Stop/Set” and “Close” buttons and hold them down
  2. Either L1 will flash (meaning no motor type has been selected yet), or one of the LEDs L1 to L8 will light up (meaning a motor type has already been selected). Then release the buttons.
  3. Use the “Open” and “Close” buttons to select the LED corresponding to the motor type according to the table (you have 10 seconds):
    L1 Moby MB4024, Moby MB5024, Hyppo HY7024, Hyppo HY7124
    L2 Metro ME3024
    L3 Toona 4 TO4024, X-Metro XME2124
    L3 Toona 5 TO5024
    L5 Toona 7 TO7024
    L6 Big-Metro BM5024
    L7 METROELITE
    L8 WINGOELITE
  4. Press the “Stop/Set” button for about three seconds, until L1starts flashing, then release it.
  5. Press the “Stop/Set” and “Close” buttons for about three seconds, until L3 and L4.
  6. The following manoeuvres should begin in this order (if the motors run in the opposite direction, i.e. start opening instead of closing, press “Open” or “Close” and reverse the motor wiring: terminals 7–9 for M1, terminals 10–12 for M2):
    1. Slow motor closing M1
    2. Slow motor closing M2
    3. Slow motor opening M1 and M2
    4. Rapid motor closing M1 and M2
  7. Otherwise, if the gate is opening in the correct direction, wait until the operator completes the gate opening and closing cycle.

Programming the operator control unit

The MC824H control unit allows you to program several functions, either by switching a function on or off by programming Level I., or by setting a default parameter by programming Level II.

MCA1 control unit has three buttons for operating and programming the operator:

NICE MCA1 operator control unit Button Use
Open The button sends an open command to the operator. It is also used during programming to move the value of the parameter being programmed up.
Stop/Set The button sends a stop command to the operator. Press and hold it for 5 seconds to enter Level I programming. Press and hold it again to enter Level II programming. for the current LED.
Close The button sends a close command to the operator. It is also used during programming to move the value of the parameter being programmed down.

 

Programming Level I.

In Level I, programming switches the selected function on or off. When a function is enabled, the corresponding LED on the control unit lights up. All functions are disabled by default.

To enter Level I programming, press and hold the “Stop/Set” button for about 5 seconds, until LED L1 starts flashing. Then use the “Open” and “Close” buttons to move the selected LED up or down. You have 10 seconds for each operation; otherwise, the operator exits programming mode. Once the flashing LED is positioned above the LED for the function you want to enable or disable, press the “Stop/Set” button once to make the flashing faster (function enabled) or slower (function disabled), then leave it as is and let the operator exit programming mode within 10 seconds. If everything went as expected, the LED for the selected function will remain lit.

List of functions that can be enabled or disabled:

LED Function Description
L1 Automatic closing After a set period (configured under “Level II programming – Pause duration”), the gate will start closing automatically after it has opened. If this function is disabled, the gate can only be operated by a command from the gate remote control and similar devices.
L2 Close after photocell interruption

This function keeps the gate open only for the minimum time needed for a vehicle to pass through. When the photocells are cleared (once the vehicle has passed through), the gate starts closing automatically after 5 seconds. This function behaves in two different ways depending on whether automatic closing is enabled (see the previous function).

Automatic closing enabled – the gate stops when the photocells are cleared and starts closing after 5 seconds. This means it does not have to open all the way.
Automatic closing disabled – the gate always opens fully (even if the photocells are cleared) and starts closing after 5 seconds.

L3 Always close After a power failure, the gate either remains in its current position (if this function is disabled) or closes (if the function is enabled).
L4 Standby mode This function reduces power consumption to a minimum. It is ideal when powered by a backup battery (e.g. NICE PS124). When this function is enabled, the control unit switches off one minute after the gate last moved BlueBUS input (and therefore all devices connected to it), and all LEDs except the BlueBUS LED, which will flash slowly. In this state, if a command is received, control unit will restart first and then carry out the command.
L5 Electric lock/Automatic lighting If this function is disabled, the ELS output acts as an electric lock; if the function is enabled, the ELS output can be used for automatic lighting.
L6 Pre-flashing After receiving a gate movement command, the beacon flashes for three seconds to warn people nearby, then the requested movement cycle begins.
L7 Close means partial opening Command close always starts a gate opening cycle.
L8 Gate-open indicator/Maintenance indicator If this function is disabled, the S.C.A. output acts as a gate-open indicator; if the function is enabled, the S.C.A. output acts as a maintenance indicator.

 

Programming Level II.

In Level II, programming sets the values for the various functions (these functions differ from those in Level I.).

Forget about Level I programming. Enter Level II programming by holding down the “Stop/Set” button for approx. 5 seconds, until LED L1. Then use the “Open” and “Close” buttons to move the current LED up or down. You have 10 seconds for each operation; otherwise, the drive will exit programming mode. When the flashing LED reaches the function LED whose parameter you want to set, press and hold the “Stop/Set” button to enter the settings for that LED. The LED that remains lit (while you continue to hold “Stop/Set”) indicates the current parameter value. You can change this value up or down using the “Open” and “ "Close” buttons (while continuing to hold the “Stop/Set” button). Then release “Stop/Set” and leave the drive untouched so it exits programming mode within 10 seconds. To check that everything went as expected, repeat the procedure without changing the parameter value.

List of programmable functions:

Input LED — Name
Description

Setting LED — Value
L1 — Pause duration

If the “Automatic closing” value in Level I programming is
enabled, this sets the time interval between the gate opening and closing automatically.

L1 — 5 seconds
L2 — 15 seconds
L3 — 30 seconds
L4 — 45 seconds
L5 — 60 seconds
L6 — 80 seconds
L7 — 120 seconds
L8 — 180 seconds

L2 — Step-by-step mode

Sets the gate movement sequence triggered by repeatedly pressing, for example, the button on the gate remote, or by activating the STEP-BY-STEP input (also known as P.P., or Step-by-step operation). If you set L4, L5, L7 or L8, the OPEN and CLOSE.

inputs will also be affected. L1 — Open/Stop/Close/Stop
L2 — Open/Stop/Close/Open
L3 — Open/Close/Open/Close
L4 — Condominium
L5 — Condominium with 2-second stop
L6 — Step-by-step operation with 2-second partial opening
L7 — Hold-to-run
L8 — Semi-automatic opening, hold-to-run closing

L3 — Motor speed

Sets the gate speed during normal operation (not during gate acceleration or deceleration).
"L6 - Extremely fastmeans 100% of 0.31 m/s etc.

L1 — Very slow (30%)
L2 — Slow (45%)
L3 — Medium (55%)
L4 — Fast (70%)
L5 — Very fast (85%)
L6 — Extremely fast (100%)
L7 — Opens “Fast”, closes “Slow”
L8 — Opens “Extremely fast”, closes “Fast”

L4 — Motor release after closing

Sets how long (in ms) the control unit releases the motor after closing to reduce pressure on the gate leaf.

L1 — None
L2 — Minimum (100 ms)
L3 — ...
L4 — ...
L5 — ...
L6 — ...
L7 — ...
L8 — Maximum (800 ms)

L5 — Motor force

Adjusts the motor force control system to suit the weight of the gate.

L1 — Low
L2 — ...
L3 — ... (default)
L4 — ...
L5 — ...
L6 — ...
L7 — ...
L8 — Extra high

L6 — Partial opening

Sets the travel distance for partial opening. For L5 to L8, “minimum” means the smaller of the two set opening angles for the gate leaves. For example, if leaf M1 opens to 90° and leaf M2 to 110°C, the minimum is 90°.

L1 — Leaf M2 opens one-quarter
L2 — Leaf M2 opens halfway
L3 — Leaf M2 opens three-quarters
L4 — Leaf M2 opens fully
L5 — Leaves open to one-quarter of the minimum
L6 — Leaves open to half the minimum
L7 — Leaves open to three-quarters of the minimum
L8 — Leaves open to the minimum

L7 — Maintenance reminder

Sets the number of gate cycles after which the drive indicates that maintenance is required.

L1 — 500 ×
L2 — 1000 ×
L3 — 1500 ×
L4 — 2500 ×
L5 — 5000 ×
L6 — 10000 ×
L7 — 15000 ×
L8 — 20000 ×

L8 — Error log

Plays the type of the last up to 8 error messages.

L1 — Result of maneuver 1
L2 — Result of maneuver 2
L3 — Result of maneuver 3
L4 — Result of maneuver 4
L5 — Result of maneuver 5
L6 — Result of maneuver 6
L7 — Result of maneuver 7
L8 — Result of maneuver 8

 

Connecting additional external devices to the drive

NICE Robus RB600 drive power supply

If you need to connect additional devices to the drive that require an external power supply (e.g. indicator lighting, key switch, card readers, etc.), connect the device as shown in the diagram. The supplied voltage is 24 V DC, −30% to +50%, with a maximum current of 200 mA.

Special control unit functions

Memory clearing

Press the buttons "Open" and "Close" and hold them until L1 and L2 start flashing.

Forced movement

If a safety device fails, or an immovable obstacle gets in the beam of, for example, photocells and the gate will not move for safety reasons, you can activate the "Dead Man" mode, either permanently in Level II programming under the setting L2 - Step-by-step mode to the value L7 - Dead Man, or temporarily:

  1. Send a command to the gate (using the remote control, using the key switch etc.)
  2. If there is a problem, the gate will not move and the warning light will probably indicate an error.
  3. Therefore, within 3 seconds of the previous command, issue the command again and hold it.
  4. The gate will move while you hold the command and stop when you release it.

Maintenance warning

In Level II programming at item L7 - Maintenance warning you can set the number of cycles after which the drive should signal that maintenance (inspection) is due. The drive signals this using the warning light (or via the S.C.A. output, if configured in Level II programming at item L4 - Output indicator level L7 - Maintenance) as follows:

Number of cycles Warning light signal S.C.A. output indicator signal
less than 80% of the limit Normal operation, flashing at half-second intervals. “On” for 2 seconds after opening starts.
80–100% of the limit On for 2 seconds after the maneuver starts, then operates normally. Flashes during the maneuver.
over 100% of the limit On for 2 seconds after the maneuver starts, then operates normally; on for 2 seconds after the maneuver ends. Flashes continuously.

For instructions on clearing the maintenance warning and checking the current number of cycles against the limit, see Table 12 in the manual.

Troubleshooting the drive

If anything is unclear or you have any other issue, feel free to contact our technical support for NICE drives.

Depending on the nature of the problem

During installation (or if the drive fails), you may encounter one of the following problems:

Problem

Possible solution

The gate does not respond to the remote control, and the LED on the remote control does not light up.

Check whether the batteries in the drive remote control are working; if not, replace them. For instructions, see the manual for the relevant remote control.

The gate does not respond to the remote control, but the LED on the remote control lights up.

Check whether the remote control has been stored in the memory of the receiver properly, or try programming the remote control again.

The gate does not move and the BlueBUS LED does not flash.

 

Check whether the drive is receiving 230 V power. If it is, test both fuses and, if necessary, replace them with new ones with the same specifications.

The gate does not move and the warning light does not flash.

Check whether the command has actually been registered by the operator.

When a command is sent, using the remote control the BlueBUS LED should flash rapidly twice.

If the command is sent by another device via the STEP-BY-STEP input (P.P.), the corresponding STEP-BY-STEP LED.

The gate does not move and the warning light flashes several times.

Count the flashes and see Diagnostics using warning-light flashes.

The gate starts moving, but immediately stops and begins moving in the opposite direction.

The programmed motor force is probably too low for your gate. Check that nothing is obstructing the gate's movement and, if necessary, increase the operator force.

The gate starts moving, but the warning light does not work.

Check whether there is voltage at the FLASH output during gate operation (the voltage level is not important, approx. 10-30Vdc). If there is voltage at the output, the problem is probably with the warning light. Try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded. Check whether the wiring has short-circuited.

The gate starts moving, but the S.C.A. output does not work.

Find out the type of function programmed for the S.C.A. output and, if the output should flash, check whether there is voltage at the output (approximately 24Vdc). If there is voltage at the output, the problem is probably with the bulb. Try replacing it with a similar one to see if it works. If there is no voltage at the output, the S.C.A. output may be overloaded. Check whether the wiring has short-circuited.

 

Diagnostics using warning-light flashes

During gate operation, the warning light flashes regularly once every second. If a problem occurs, the warning light signals the fault with two faster consecutive sequences of flashes.

Flash sequence

Fault

Solution

1 flash

1-second pause

1 flash

BlueBUS fault

 

The devices connected to the BlueBUS input do not match those detected during the device detection procedure.. Run the detection procedure again. If that does not help, try once more; otherwise, use a process of elimination to find the faulty device and replace it (purchase a replacement, make a warranty claim, or have it repaired).

2 flashes

1-second pause

2 flashes

Photocell activation

The photocellsare being triggered, which is normal if their beam is interrupted while the gate is closing. If the beam has not been interrupted, the photocells may be dirty, exposed to bright light, or faulty.

3 flashes

1-second pause

3 flashes

Motor force limiter activated

 

While the gate is moving, increased friction is detected. The gate may not be properly adjusted; try moving it by hand and adjusting it. Otherwise, it usually helps to increase the motor force, or activate the Peak function.. Another possible cause is that the lower stop is set too high.

4 flashes

1-second pause

4 flashes

STOP input activated

 

A command was sent to the STOP input, so if this is unexpected, check the devices connected to it.

5 flashes

1-second pause

5 flashes

Internal control unit fault

Wait 30 seconds and try again. If the problem persists, try to reset it. Otherwise, the control unit will probably need to be repaired or replaced.

6 flashes

1-second pause

6 flashes

Hourly operation limit reached.

Wait a few minutes for the cycle limiter to drop below the limit.

7 flashes

1-second pause

7 flashes

Internal electronic circuit fault.

Disconnect the entire operator for a few seconds and try again. If the problem persists, try to reset it. Otherwise, the control unit will probably need to be repaired or replaced.

8 flashes

1-second pause

8 flashes

Continuous command active.

 

A command is being continuously sent to the operator. Check the devices connected to the OPEN input. If you have a timer connected, it is probably the cause.

 

9 flashes

1-second pause

9 flashes

The operator is locked by the "Lock automation" command. Unlock the operator using the "Unlock automation" command.
10 flashes

1-second pause

10 flashes

Encoder limit activation During movement, the gate detects increased friction; check that it moves smoothly.

Diagnostics using LED flashing

On the MCA1 control unit MC824H control unit, there are two sets of LEDs, each of which indicates normal operation of the control unit or error diagnostics by flashing or staying lit, as shown in the following tables.

BLUEBUS, STOP, PP, OPEN and CLOSE horizontal LEDs

Indicator

Status

Solution

BlueBUS LED

Off

Error

 

Check the mains connection, and if it is OK, check fuses F1 and F2 and replace them, if necessary, with new ones of the same rating.

On

Serious error

 

Try disconnecting the control unit, or all inputs. If this does not help, reset it. If that still does not help, the control unit will probably need to be replaced.

Flashing at one-second intervals

Everything is OK

The control unit is operating normally.

2 quick flashes

An input status has changed

Normal operation – an input status has changed STEB-BY-STEP, STOP, OPEN, CLOSE, were activated photocells, or the operator received a command from the remote control.

Flashing sequences separated by a one-second pause

Multiple possibilities

The number of flashes in the sequence corresponds to the error diagnostics indicated by the beacon.

STOP LED

Off

The STOP input has been activated

Check the devices connected to the STOP input.

On

Everything is OK

The STOP input is inactive.

STEB-BY-STEP LED (also labelled P.P., Step-by-step)

Off

Everything is OK

The STEP-BY-STEP input is inactive.

On

The STEB-BY-STEP input has been activated

Normal operation of the control unit if an active device was connected to the STEP-BY-STEP input.

OPEN LED

Off

Everything is OK

The OPEN input is inactive.

On

The OPEN input has been activated

Normal operation of the control unit if an active device was connected to the OPEN input.

CLOSE LED

Off

Everything is OK

The CLOSE input is inactive.

On

The CLOSE input has been activated

Normal operation of the control unit if an active device was connected to the CLOSE input.

 

Vertical LEDs L1–L8

Indicator

Solution

LED 1

Off

During normal operation, indicates that the Automatic closing function is disabled.

On

During normal operation, indicates that the Automatic closing function is enabled.

Flashing

LED 2

Off

During normal operation, indicates that the Close after photocell interruption function is disabled.

On

During normal operation, indicates that the Close after photocell interruption function is enabled.

Flashing

LED 3

Off

During normal operation, indicates that the Always close function is disabled.

On

During normal operation, indicates that the Always close function is enabled.

Flashing

LED 4

Off

During normal operation, indicates that the Standby mode function is disabled.

On

During normal operation, indicates that the Standby mode function is enabled.

Flashing

  • The function is being programmed.
  • If it flashes at the same time as L3, this means that it is necessary to perform the wing movement assessment phase.

LED 5

Off

During normal operation, indicates that the Electric lock/Automatic lighting function is disabled.

On

During normal operation, indicates that the Electric lock/Automatic lighting function is enabled.

Flashing

The function is being programmed.

LED 6

Off

During normal operation, indicates that the Pre-flashing function is disabled.

On

During normal operation, indicates that the Pre-flashing function is enabled.

Flashing

The function is being programmed.

LED 7

Off

During normal operation, indicates that the Close means Partial opening function is disabled.

On

During normal operation, indicates that the Close means Partial opening function is enabled.

Flashing

The function is being programmed.

LED 8

Off

During normal operation, indicates that the Gate open indicator/Maintenance indicator function is disabled.

On

During normal operation, indicates that the Gate open indicator/Maintenance indicator function is enabled.

Flashing

The function is being programmed.

Installing the backup battery for the NICE MC824H control unit

NICE PS324 backup battery is not included as standard with the operator, but it can be ordered separately. It is used in the event of a power failure, when it will power the gate operator. The battery is continuously charged from the mains.

1. Pry off the plastic cover from the battery connector 2. Connect the battery to the connector and place it next to the control unit
1. Pry off the plastic cover from the battery connector 2. Connect the battery to the connector and place it next to the control unit

 

Technical specifications of the NICE Moonclever MC824H control unit

Model NICE Moonclever MC824H
Type description Electrical control unit for the automatic operation of swing gates. Supplied with NICE MCA1 control unit, but without radio receiver.
Power supply 230V (+10% -15%) 50/60Hz

Power consumption

200W (below 100W with the overall standby mode)
Backup power supply available to purchase separately and install NICE PS324 backup battery
Flashing light output for one flashing light 12Vdc with a bulb rated at max. 21W (e.g. NICE Lucy LUCYB, NICE Moonlight MLBT)
Output indicator (S.C.A.) for one 21V, max. 4W bulb (output voltage +50% -30%); can operate a small relay
BlueBUS output one output for up to 15 BlueBUS devices (maximum 6 pairs of photocells MOFB/MOFOB + 2 pairs of photocells MOFB/MOFOB used for opening + 4 MOMB card readers/MOTB digital keypads)
STOP input for normally open, normally closed, and devices with a constant resistance of 8,2KΩ
STEP-BY-STEP input (P.P., step-by-step) normally open (closing the contact triggers the command "Step-by-step")
OPEN input normally open (closing the contact triggers the command "Open")
CLOSE input normally open (closing the contact triggers the command "Close")
Radio receiver without receiver, "SM" connector for receivers NICE SMXI, NICE OXI etc.
Antenna input 50Ω for RG-58 coaxial cable (or similar)
Programming functions 8 functions to switch on/off (Level I programming)
8 adjustable functions (Level II programming)
Self-diagnostic functions

leaf length detection (calculation of acceleration and deceleration distances, calculation of the partial opening point)
detection of connected devices - STOP input and BlueBUS

Operating temperature -20°C to +50°C
Use in saline, acidic, and potentially explosive environments no
Protection rating IP54
Dimensions 232×310×122 (W×D×H)
Weight 4,1kg

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range

Product: NICE Moonclever MC824H - control unit for 24V swing gate operators in the Toona range
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.