NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)


Product availability: for the question

The product may not be available, contact us for more information.


NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)

Description of NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)

MOFOB photoelectric sensors have been replaced.
            Their successor EPMB has fully compatible internal electronics (without the option to swivel). If needed, you can purchase separate replacement covers for MOFOB.

Outdoor safety photocells NICE MOFB (technical specifications) are installed opposite each other across the gate opening, or at any point where there is a risk of the gate hitting an obstacle. They create an infrared beam along the optical axis, which, when interrupted, sends a signal to the gate to stop it. They can only be used with devices that support the NICE BlueBUS technology. They can only be used with devices that support NICE BlueBUS.

They consist of two synchronised components: a TX transmitter and an RX receiver.

Installing NICE MOFB photocells

1. Mount the photocells on a wall, masonry, a post, or any other surface (surface mounting), at the same height and facing each other along the same axis. The mounting surface must be flat so that the photocells can be easily aligned:

Surface mounting NICE MOFB photocells

2. Next, connect the photocells according to the diagram supplied with your gate operator or control unit (see wiring diagram for NICE Robus 400, 600, 1000 - control unit RBA3).

3. Run the connected-device detection procedure (this procedure is supported by every gate operator or control unit with a BlueBUS).

4. To test that the wiring is correct, refer to the chapter Checking operation and troubleshooting, or continue below for information on connecting multiple pairs of photocells:

Connecting multiple pairs of photocells NICE MOFB to the NICE BlueBUS

Position the photocells around the gate or gates according to the example configurations for the complete wiring layout and set the jumpers according to the jumper settings table for the NICE MOFB gate operator. To prevent interference between pairs installed close to one another, follow these example configurations, and make sure the transmitters are oriented TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):

Parallel wiring of NICE MOFB photocells to a gate operator

If you need the photocells to open the gate (see FA1 and FA2 in the example configurations), i.e. to open the gate when a vehicle passes between their optical axes, you must disconnect link A on both the TX transmitter and the RX, as shown:

NICE MOFB photocell link A

Example configurations for fully wiring multiple pairs of photocells to a gate operator

1. Single-leaf sliding gate

Photocell wiring for a single-leaf sliding gate

2. Two synchronised sliding gates facing each other

Photocell wiring for two synchronised sliding gates facing each other

3. Swing gate

Photocell wiring for a swing gate

4. Sectional garage door

Photocell wiring for a sectional garage door

5. Up-and-over garage door

Photocell wiring for an up-and-over garage door

NICE MOFB photocell jumper settings table for gate operators

NICE MOFB photocell compartment for unused jumpers 

Connecting multiple pairs of photocells to a BlueBUS system is done by setting different jumper combinations, with each connected pair requiring a unique jumper configuration. Make sure that no two pairs on the same BlueBUS data network have the same configuration. For each pair of photocells, set the jumper on the TX transmitter and RX receiver to the same value. If a jumper configuration uses only one jumper, always store the other one in the unused jumper holder, as shown in the image on the left.

Photocell pair designation Jumper setting using a combination of jumpers
FOTO MOFB photocell jumper setting for FOTO
FOTO II MOFB photocell jumper setting for FOTO II
FOTO 1 MOFB photocell jumper setting for FOTO 1
FOTO 1 II MOFB photocell jumper setting for FOTO 1 II
FOTO 2 MOFB photocell jumper setting for FOTO 2
FOTO 2 II MOFB photocell jumper marked FOTO 2 II
FOTO 3 MOFB photocell jumper marked FOTO 3

FA1
(Break the connection A 
on the TX transmitter
and RX receiver)

MOFB photocell jumper marked FA1

FA2 
(Break the connection A
on the TX transmitter
and RX receiver)

MOFB photocell jumper marked FA2

 

If a photocell needs to be replaced for any reason, simply set it to the same jumper as the original one; there is no need to perform the device recognition procedure.

NICE MOFB photocell operation check and wiring troubleshooting

NICE MOFB drive photocell LED


After the drive's device recognition procedure, check that the LED on both the TX transmitter and RX receiver is flashing. The LED may flash in the following ways:

 

LED "L" Status What to do
Off The photocell is not powered or is faulty. Check that the voltage at the photocell inputs is approximately 8-12V. If the voltage is correct, the photocells are probably faulty.
3 quick flashes followed by a one-second pause The device has not been recognized by the drive control unit. Repeat the recognition procedure on the control unit. Make sure that each pair of photocells has a unique address assigned using jumpers .
Very slow flashing The TX transmitter is transmitting regularly
The RX receiver is receiving an excellent signal
Normal operation
Slow flashing The RX receiver is receiving a good signal Normal operation 
Fast flashing The RX receiver is receiving a weak signal Normal operation. However, it is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean. 
Very fast flashing The RX receiver is receiving a very weak signal Still operating normally, but near the limit. It is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean. 
On The RX receiver is not receiving any signal Make sure the TX LED is flashing slowly. Check for an obstruction in the optical path between the TX transmitter and RX receiver. Check the alignment of the TX and RX.

 

NICE MOFB photocell technical specifications

Product type Type D detector for automatic swing gates, sliding gates and garage doors in accordance with EN 12453, consisting of a transmitter TX and a receiver RX.
Technology Direct optical TX-RX link with a modulated infrared beam.
Power supply/output The device can only be connected to a data network that supports the NICE BlueBUS, from which it receives electrical power and sends an output signal.
Current consumption 1 BlueBUS unit
Detection capability Opaque objects larger than 50 mm passing through the optical axis between the TX transmitter and RX receiver at a speed below 1.6 m/s.
TX transmitter beam angle 20° +-25%
RX receiver acceptance angle Approximately 20°
Nominal range 15 m with a maximum TX transmitter and RX receiver axis misalignment of +-5%, even in poor weather conditions
Maximum range 30 m with a maximum TX transmitter and RX receiver axis misalignment of +-5% in excellent weather conditions
Addressing 7 pairs with a safety function and 2 pairs with an "Open" command function
Use in acidic or saline environments, or in environments with an increased risk of explosion No
Installation Vertical wall mounting
Protection rating  IP55
Operating temperature -20°C to 55°C
Dimensions 69x78x25mm
Weight 50g

 

Wiring the NICE MOFB photocells to the NICE Robus 400, 600, 1000

Wiring NICE MOFB photocells to a NICE Robus 400, NICE Robus 600 or NICE Robus 1000 drive

Inside the NICE MOFB gate drive photocells

Photocells for the NICE MOFB gate drive

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)

Product: NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.