NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
Description of NICE MoonBus MOFOB – adjustable 30° drive photocells (1 pair)
MOFOB photoelectric sensors have been replaced.
Their successor EPMB has fully compatible internal electronics (without the option to swivel). If needed, you can purchase separate replacement covers for MOFOB.
Outdoor safety photocells NICE MOFB (technical specifications) are installed opposite each other across the gate opening, or at any point where there is a risk of the gate hitting an obstacle. They create an infrared beam along the optical axis, which, when interrupted, sends a signal to the gate to stop it. They can only be used with devices that support the NICE BlueBUS technology. They can only be used with devices that support NICE BlueBUS.
They consist of two synchronised components: a TX transmitter and an RX receiver.
Installing NICE MOFB photocells
1. Mount the photocells on a wall, masonry, a post, or any other surface (surface mounting), at the same height and facing each other along the same axis. The mounting surface must be flat so that the photocells can be easily aligned:
2. Next, connect the photocells according to the diagram supplied with your gate operator or control unit (see wiring diagram for NICE Robus 400, 600, 1000 - control unit RBA3).
3. Run the connected-device detection procedure (this procedure is supported by every gate operator or control unit with a BlueBUS).
4. To test that the wiring is correct, refer to the chapter Checking operation and troubleshooting, or continue below for information on connecting multiple pairs of photocells:
Connecting multiple pairs of photocells NICE MOFB to the NICE BlueBUS
Position the photocells around the gate or gates according to the example configurations for the complete wiring layout and set the jumpers according to the jumper settings table for the NICE MOFB gate operator. To prevent interference between pairs installed close to one another, follow these example configurations, and make sure the transmitters are oriented TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
If you need the photocells to open the gate (see FA1 and FA2 in the example configurations), i.e. to open the gate when a vehicle passes between their optical axes, you must disconnect link A on both the TX transmitter and the RX, as shown:
Example configurations for fully wiring multiple pairs of photocells to a gate operator
1. Single-leaf sliding gate
2. Two synchronised sliding gates facing each other
3. Swing gate
4. Sectional garage door
5. Up-and-over garage door
NICE MOFB photocell jumper settings table for gate operators
|
Connecting multiple pairs of photocells to a BlueBUS system is done by setting different jumper combinations, with each connected pair requiring a unique jumper configuration. Make sure that no two pairs on the same BlueBUS data network have the same configuration. For each pair of photocells, set the jumper on the TX transmitter and RX receiver to the same value. If a jumper configuration uses only one jumper, always store the other one in the unused jumper holder, as shown in the image on the left. |
| Photocell pair designation | Jumper setting using a combination of jumpers |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
| FOTO 3 | ![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If a photocell needs to be replaced for any reason, simply set it to the same jumper as the original one; there is no need to perform the device recognition procedure.
NICE MOFB photocell operation check and wiring troubleshooting
![]() |
After the drive's device recognition procedure, check that the LED on both the TX transmitter and RX receiver is flashing. The LED may flash in the following ways: |
| LED "L" | Status | What to do |
|---|---|---|
| Off | The photocell is not powered or is faulty. | Check that the voltage at the photocell inputs is approximately 8-12V. If the voltage is correct, the photocells are probably faulty. |
| 3 quick flashes followed by a one-second pause | The device has not been recognized by the drive control unit. | Repeat the recognition procedure on the control unit. Make sure that each pair of photocells has a unique address assigned using jumpers . |
| Very slow flashing | The TX transmitter is transmitting regularly The RX receiver is receiving an excellent signal |
Normal operation |
| Slow flashing | The RX receiver is receiving a good signal | Normal operation |
| Fast flashing | The RX receiver is receiving a weak signal | Normal operation. However, it is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean. |
| Very fast flashing | The RX receiver is receiving a very weak signal | Still operating normally, but near the limit. It is best to check the alignment of the TX transmitter and RX receiver and make sure the covers are clean. |
| On | The RX receiver is not receiving any signal | Make sure the TX LED is flashing slowly. Check for an obstruction in the optical path between the TX transmitter and RX receiver. Check the alignment of the TX and RX. |
NICE MOFB photocell technical specifications
| Product type | Type D detector for automatic swing gates, sliding gates and garage doors in accordance with EN 12453, consisting of a transmitter TX and a receiver RX. |
|---|---|
| Technology | Direct optical TX-RX link with a modulated infrared beam. |
| Power supply/output | The device can only be connected to a data network that supports the NICE BlueBUS, from which it receives electrical power and sends an output signal. |
| Current consumption | 1 BlueBUS unit |
| Detection capability | Opaque objects larger than 50 mm passing through the optical axis between the TX transmitter and RX receiver at a speed below 1.6 m/s. |
| TX transmitter beam angle | 20° +-25% |
| RX receiver acceptance angle | Approximately 20° |
| Nominal range | 15 m with a maximum TX transmitter and RX receiver axis misalignment of +-5%, even in poor weather conditions |
| Maximum range | 30 m with a maximum TX transmitter and RX receiver axis misalignment of +-5% in excellent weather conditions |
| Addressing | 7 pairs with a safety function and 2 pairs with an "Open" command function |
| Use in acidic or saline environments, or in environments with an increased risk of explosion | No |
| Installation | Vertical wall mounting |
| Protection rating | IP55 |
| Operating temperature | -20°C to 55°C |
| Dimensions | 69x78x25mm |
| Weight | 50g |
Wiring the NICE MOFB photocells to the NICE Robus 400, 600, 1000
Inside the NICE MOFB gate drive photocells

How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]