NICE RUN1200 HS – high-speed operator for sliding gates (A)

NEW


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE RUN1200 HS – high-speed operator for sliding gates (A) NICE RUN1200 HS – high-speed operator for sliding gates (A)
NICE-RUN1200HS-A
in stock
€720.18 excluding VAT
€885.82 including VAT

 pcs
Weight
13 kg

Description of NICE RUN1200 HS – high-speed operator for sliding gates (A)

NICE RUN1200HS is fast non-reversible electromechanical operator for sliding gates weighing up to 1,200 kg. It has a 24 V DC motor, built-in RUA6 and an electromechanical limit switch. The complete operator connects to the 230 V ACmains; the motor voltage and the power supply for the assembly are separate specifications.

The no-load speed is approximately 0.37 m/s (22 m/min). A 7 m passage takes approximately 18–19 s; the actual opening time is longer due to acceleration, deceleration and load. Suitable where fast passage is important, provided all safety requirements are met. When planning operation, use limits based on length and weight, not a single cycle count for every gate.

This is a standalone operator for one sliding gate leaf. In the event of a power failure, it can be released with a key. Choose the receiver, transmitter and safety accessories to suit the equipment you need; see the complete options in the kit overview.

Quick navigation
Selection and limitsAccessories
KitsInstallation
WiringPhotocells
Initial startupProgramming
TroubleshootingMaintenance
Manual releaseSpecifications
PDF manual

Compatible accessories

WhatWhyType
Warning lightsWarns that the gate is moving. Choose a version for FLASH and an antenna compatible with the receiver frequency. FLASH wiring.
PhotocellsThey protect the passage according to their address; BlueBUS uses two non-polarised wires. Wiring and addresses.
Wireless photocellsEPMOW requires the IBW interface. FT210B has a battery-powered transmitter and a receiver connected to BlueBUS; it can also transmit the signal from a moving safety edge.
Radio receiversInstall the plug-in SM receiver with the power disconnected. The transmitter's coding and frequency must be compatible with the selected receiver.
TransmittersGate control; the ON3ELR long-range transmitter requires an LR receiver. Two-way functions require a compatible receiver. Pairing.
AntennaFor better range. Connect the coaxial cable to the antenna input; the frequency must match the receiver.
Key switches / keypads / readersThe key switch's voltage-free contacts control P.P./OPEN/CLOSE. BlueBUS keypads and readers are enrolled as devices; radio models are paired with the receiver.
Wi-Fi / GSM controlThe universal module controls P.P. via an isolated voltage-free COM–NO contact; select the power supply separately according to voltage and current draw limit. BiDi-WiFi is not compatible with RUA6.
RackModule 4; select the material, fixing method and load capacity to suit the complete gate leaf. A nylon rack is not automatically suitable for every heavy gate. Rack installation.
Backup powerRUA6 uses a separate charger and two matching 12 V batteries. Choosing a backup power supply.

With an existing installation, older components may remain functional LUCYB, MLBT, ELB, MOFB, MOSE, MOTXR, SMXI. When replacing a component, check the voltage, interface and coding; compatibility with an older component does not mean it is still in current production. Choose new equipment from the compatible alternatives listed above.

Kits and standalone operator

The kits differ in their included accessories, not in the motor's limit. Each kit contains one operator; the rack length must be suitable for the entire gate travel.

Kit with photocells and warning lightStandalone operatorKit with rack
NICE RUN1200HS – kit D

NICE RUN1200HS D kit

Operator, receiver OXIBD, transmitter MYGO4, pair EPMB and warning light ELDC.
Without rack.

NICE RUN1200HS – standalone operator

Standalone NICE RUN1200HS operator

RUA6 control unit in the operator. Select the receiver, transmitter, photocells, warning light and rack separately.

NICE RUN1200HS – F kit

NICE RUN1200HS F kit

Operator, receiver OXIBD, transmitter MYGO4, pair EPMB and warning light ELDC.
In addition 4 m LZ-1.

Another optionAdditional equipment for the operator
Kit BOXIBD + MYGO4
Kit COXIBD + MYGO4 + pair of EPMB
Kit EEquipment C + 4 m LZ-1

For a kit with 4 m of rack and a longer gate, purchase the additional length required; also check that the rack is suitable for the gate's weight and operating frequency. The contents of each kit are listed on its product page.

You can find more models to compare in the NICE Hi-Speed fast operators. Each model has its own limits and equipment.

Choosing an operator and operating limits

The weight and length of the entire moving gate leaf, including the infill and counterweight, are what matter—not just the clear opening width. The gate must move smoothly along its entire travel, with correct guidance and solid mechanical stops. Measure the resistance at startup and while moving, and allow a margin for conditions to worsen in winter.

ParameterLimit for one operator
Gate leaf weight1 200 kg
Gate leaf length14 m
Limit switchElectromechanical – brackets on the rack operate the lever

Reaching both maximum values does not automatically mean the gate is suitable. Also check the sum of load indices and the following cycle limits. Higher speed does not increase the permitted weight or remove safety requirements.

Number of cycles by length and weight

One cycle is a complete opening and closing operation. Multiply the number of cycles per hour and consecutive cycles from the row for the gate length by the weight coefficient. Round down for planning purposes. Temperature and mechanical resistance may reduce the result further.

Gate leaf lengthMax. cycles/hourMax. consecutive cycles
Up to 4 m3621
Over 4 up to 6 m2615
Over 6 up to 8 m2312
Over 8 up to 10 m1710
Over 10 up to 12 m148
Over 12 up to 14 m137

Gate leaf weightAvailable cycle coefficient
50–100 kg100%
Over 100 up to 200 kg80%
Over 200 up to 400 kg75%
Over 400 up to 550 kg60%
Over 550 up to 800 kg50%
Over 800 up to 1 000 kg40%
Over 1 000 up to 1 200 kg30%

Example: 7 m / 900 kg gate leaf → 23 × 0.40 and 12 × 0.40. For planning, no more than 9 cycles/hour and 4 consecutive cycles, before applying further restrictions. The figure of 60 cycles/hour is not an operating limit for just any gate; the tables and conditions of the specific setup determine the limit.

Estimated service life

Add together the indices for weight, length and other relevant factors. Include other factors if their likelihood of occurrence is greater than 10%. The graph shows the approximate number of cycles with regular maintenance, not a guarantee or a number of years. The horizontal axis shows the sum of the indices in %, and the vertical axis shows the number of cycles.

Properties of the complete automation systemIndexService life graph
Weight50–100 kg → 5%
over 100–200 kg → 10%
over 200–400 kg → 20%
over 400–550 kg → 30%
over 550–800 kg → 40%
over 800–1 000 kg → 50%
over 1 000–1 200 kg → 60%
NICE RUN1200HS – estimated service life in cycles graph
LengthUp to 6 m → 5%
Over 6–9 m → 10%
Over 9–12 m → 15%
Over 12–14 m → 20%
Temperature / humidityOver 40 °C or below 0 °C / humidity over 80% → 10%
Dust and sand15%
Saline environment20%
Photocell interruption10%
STOP interruption20%
Peak function ON10%

If the total exceeds 100%, the conditions are beyond acceptable limits. Choose the operator based on the entire gate and its operating conditions; meeting the weight limit alone does not guarantee suitability.

If you need help verifying your choice, contact us with the gate’s length, weight, and estimated number of cycles.

Installing a sliding gate and operator

Before installation, disengage the operator and check that the gate moves smoothly by hand, is guided securely, is protected against lifting off, and has firm stops at both end positions. The gate must not move on its own. Protect the operator from flooding; the mounting surface must be firm and allow safe manual release.

  1. Install cable conduits and a foundation plate with four anchors. Leave no more than 40 mm.
  2. Level the plate according to the original drawing, parallel to the gate leaf. Allow the concrete to cure completely.
  3. Secure the motor with nuts and washers, adjust its position relative to the rack, then tighten the fasteners securely.
  4. Secure the cables against being pulled out and contact with moving parts. Restore all seals on the cable glands and cover.

NICE RUN1200HS – original foundation plate installation drawing

Rack and pinion clearance

Use a compatible module 4 rack; choose the material and load capacity to suit the gate. The weight of the gate leaf must not rest on the pinion. Maintain a 1–2 mm clearance along the entire travel.

1–2 mm clearance between the rack and pinion

Align the rack sections with the pinion; lateral deviation during manual movement must not exceed 5 mm. Check that the joints are smooth and each section is securely fastened. Do not use greater motor force to compensate for an incorrectly installed rack.

Electromechanical limit switches

  1. Move the gate leaf by hand to the open position, stopping at least 2–3 cm before the fixed stop.
  2. Slide the bracket along the rack in the opening direction until it activates the limit switch. Move it further in the same direction by at least 2 cm and secure it.
  3. Set the bracket for the closed position in the same way.
  4. After engaging the operator and programming the travel, check that the gate stops before both fixed stops. Limit switch brackets do not replace mechanical stops.

NICE RUN1200HS – mechanical limit switch bracket

Wiring

ConnectionCross-section / typeMax. length
230 V mains supply3 × 1.5 mm²30 m
FLASH2 × 0.5 mm²20 m
AntennaRG58 coaxial cable20 m; under 5 m recommended
BlueBUS2 × 0.5 mm²30 m
Key switch2 cables, 2 × 0.5 mm² or 4 × 0.5 mm²50 m
Safety edge connection2 × 0.5 mm²30 m; flexible cable or FT210B recommended

For mains cables longer than 30 m, use a larger cross-section, for example 3 × 2.5 mm², and suitable protective earthing. For BlueBUS runs over 30 m and up to 50 m, use 2 × 1 mm². Select cable cross-sections and protection according to the route, environment, and voltage drop; signal cables are not a substitute for mains wiring.

Electrical connections and RUA6 control unit

Before opening the unit or changing terminal connections, disconnect the mains supply and backup batteries, then verify that the circuit is de-energized. The mains supply, motor, and accessory outputs have different functions and voltages.

230 V AC supply

TerminalConnection
LLive conductor
NNeutral conductor
PE / earth symbolProtective green/yellow conductor; a Class I operator must be earthed

NICE RUN1200HS – L and N supply and protective earthing

Route the mains cable through the separate smaller cable gland. Secure the accessory wires in the larger cable gland; leave approximately 20–30 cm of slack inside. The membranes must fit tightly around the cables, and the wiring must not obstruct the cover.

Terminal layout and functions

RUA6 – original detail showing terminal and antenna labels

TerminalPurpose, voltage, and polarity
FLASHOutput for a warning light, rated according to the wiring diagram at 12 V / 21 W per bulb, up to two bulbs. ELDC or WLT connect according to their instructions; this is not a continuous power supply. For a polarized warning light, follow the terminal markings on the light and the FLASH output. The +/− order for the 24 V auxiliary power supply does not apply to FLASH.
S.C.A.Indicator output 24 V DC, max. 4 W, tolerance −30% / +50%. Function according to II/L4. For polarized devices, check the actual output markings; do not connect the auxiliary power +/− here.
BLUEBUSPower and communication for compatible devices, using two wires connected in parallel with no polarity. Limit of 15 BlueBUS load units, not 15 pairs of photocells.
STOPPotential-free NO, NC or 8.2 kΩ resistive devices. The controller interprets a change in the learned state as a stop with a brief reverse movement. No power supply +/−.
P.P. / STEP-BY-STEPPotential-free NO contact for step-by-step control. Connect the accessory relay COM–NO to both P.P. terminals; no polarity. The module's power supply is a separate pair.
OPENPotential-free NO contact for opening; no polarity.
CLOSEPotential-free NO contact for closing; when I/L7 is ON, it triggers partial opening. No polarity.
ANTENNA / AERIALConnect the coaxial cable's center conductor and shield according to the antenna input markings. These are not power supply +/− terminals; select the correct frequency.

Auxiliary power supply – exact polarity

Power for an external module can be drawn at 24 V DC, −30% / +50%, 100 mA total maximum. The module must tolerate a range of approximately 16.8–36 V. The positions below apply when the STOP and P.P. connectors are oriented the same way as in the original image.

Power / commandRUA6 terminalModule connection
Negative −Right STOP terminal− / GND
Positive +Left P.P. terminal+ / V+
Step-by-step commandBoth P.P. terminalsIsolated potential-free COM–NO contact

RUA6 – auxiliary 24 V DC: right STOP terminal is negative, left P.P. terminal is positive

For higher current draw, an unsuitable voltage range or current spikes, use a separate power supply. Connect only an isolated potential-free command to P.P. Do not use BlueBUS or FLASH instead of the auxiliary power supply.

EKS key switch

For EKS use one pair C–NO for the two OPEN terminals, and the other pair C–NO for the two CLOSE terminals. Do not use NC contacts for these commands. For control using a single step-by-step contact, connect C–NO to both P.P. terminals. These are potential-free contacts with no polarity; do not apply 230 V or an external 24 V supply to the command inputs.

Safety edges and STOP

Connect NO contacts in parallel and NC contacts in series. Two 8.2 kΩ resistive devices can be connected in parallel; more devices require the specified cascade wiring with an end resistor. A combination of NO and NC uses the NC branch with an 8.2 kΩ resistor, as shown in the relevant wiring diagram. Repeat the learning procedure and safety test after every change; do not replace a safety edge with a simple jumper.

BlueBUS photocells and addressing

Current EPMB and other compatible BlueBUS photocells connect in parallel to the BLUEBUS pair, with no polarity. The TX and RX of each pair must have the same jumper settings. Set a different supported address for each additional pair. After adding, removing or changing the address, always repeat the device learning procedure.

AddressPosition and response
FOTOOuter pair, approximately 50 cm above ground; reverses movement when closing.
FOTO IIOuter pair, approximately 100 cm above ground; reverses movement when closing.
FOTO 1Inner pair, approximately 50 cm; reverses movement when closing.
FOTO 1 IIInner pair, approximately 100 cm; reverses movement when closing.
FOTO 2Outer pair for protection during opening.
FOTO 2 IIInner pair for protection during opening.
FOTO 3One pair for protection during both opening and closing; position it so that it does not interfere with the other pairs.

For the specific jumper settings, see EPMB photocells – jumper settings table. Select the protective function according to the actual gate's hazard zones; height alone does not determine safety. For EPMOW, you need the IBW interface. For FT210B the transmitter is battery-powered, and the receiver connects to BlueBUS.

Special mode 2 – BlueBUS changes to 12 V

Mode 2 is an alternative wiring option for standard photocells, not a setting for BlueBUS photocells. To activate it, hold OPEN + SET for more than 8 seconds. Release only when L1/L2 are flashing very rapidly, wait for recognition to finish, and check that the STOP LED is lit. BlueBUS changes to an AUX output 12 V DC / max. 6 W; OPEN and CLOSE take over the PHOTO and PHOTO 2 functions. BlueBUS devices must not be connected to this pair in this mode.

Output in mode 2Polarity relative to the original image
Former BLUEBUS pair – AUX 12 V DCLeft +, right −; connect + to + and − to − on the accessory

RUA6 – mode 2 only: AUX 12 V DC, left terminal positive and right terminal negative

Select the mode before wiring and follow the complete procedure in the installation manual. This +/− marking does not apply in standard BlueBUS mode, in which compatible photocells are connected without polarity.

Initial start-up and learning procedure

Check the mounting, stops, opening directions, and all terminals. Leave the gate leaf approximately in the middle of the track and lock the gearbox. After switching on, BLUEBUS should flash approximately once per second; the photocells must indicate normal operation. If an error occurs, disconnect the power first and eliminate the cause.

Setting the opening direction

With the power disconnected, set the direction switch according to the drive position and the direction of gate-leaf movement. In the same orientation as shown in the picture: opening to the left = switch on the left; opening to the right = switch on the right. After switching on, verify that the first movement during learning is opening.

Opening to the leftOpening to the right
RUN1200HS – opening to the left, switch on the leftRUN1200HS – opening to the right, switch on the right

Recognizing devices and the STOP input

  1. Press and hold OPEN + STOP/SET for approximately 3 seconds.
  2. Release when L1 and L2 flash rapidly.
  3. Wait for the process to finish. L1/L2 will stop flashing to indicate that learning is requested, and the STOP LED must be lit. L3/L4 may continue to indicate that travel learning is required.
  4. After changing BlueBUS or STOP, repeat the procedure and test each safety device separately.

Travel learning

  1. After the devices have been recognized successfully, press and hold CLOSE + STOP/SET for approximately 3 seconds.
  2. Release when movement begins. The first movement must be opening.
  3. If the gate closes, stop it using STOP, disconnect the power, and correct the direction setting. Then repeat the learning procedure.
  4. Allow the gate to open fully to the limit switch and then close fully. Keep people and obstacles clear of the travel path.
  5. Check both end positions, partial opening, slowdown, and several complete cycles.

The standard procedure uses slowdown approximately 50–70 cm before the end. Alternatively, travel learning with CLOSE + SET held for more than 8 seconds sets slowdown to approximately 10 cm and uses a very high speed. After 8 seconds, release the buttons when L3/L4 flash very rapidly, then let travel learning finish; this is not the standard procedure for every gate. Use this only with suitable mechanics, verified safety, and subsequent force measurement. Do not confuse it with device recognition mode 2.

Testing and handover

Check opening and closing, stopping before the stops, accessories, and protection of all hazardous areas. Test photocells and safety edges individually in both directions, according to their function. If the safety system relies on force limitation, impact forces must be measured; repeat the test after changing the speed, force, sensitivity, or acceleration. The user must be given the keys and instructions on manual release, safe operation, and maintenance.

Two drives – Master/Slave

For two opposing sliding gate leaves, each motor must have its own mains supply. Use two compatible drives and the correct control procedure; two motors do not increase the limit for a single gate leaf. The BlueBUS connection must follow the sequence 1 Master → 1 Slave and 2 Master → 2 Slave with the connectors oriented the same way, as shown in the original diagram in the installation PDF. Numbers 1/2 indicate positions, not power +/−.

  1. With the power disconnected, set the directions for both gate leaves and connect them according to the Master/Slave diagram.
  2. Connect the shared controls and receiver to the Master. On the second drive, set I/L8 = ON.
  3. Recognize the devices on the Slave first, then on the Master.
  4. Start travel learning on the Master and check the movement of both gate leaves and all safety devices.

FLASH, S.C.A., STOP, and P.P. can be connected separately to the Slave. P.P. on the Slave opens only its own gate leaf fully; OPEN/CLOSE are not used on the Slave. Consider the safety settings and diagnostics for the second drive as well.

Receiver and remote control

With the power disconnected, install the receiver in its SM socket. The pairing and memory-clearing procedure depends on the receiver OXIBD, OXI or OXILR; use its button, LED indicators, and the NICE remote control pairing guide. Gate travel learning is not transmitter pairing or clearing the radio memory.

RUA6 programming

The OPEN ▲ and CLOSE ▼ buttons change the selection; STOP/SET stops and confirms settings. The control board has LEDs L1–L8. The gate must remain stationary during setup. Record the original values before making changes; test the system after adjusting safety settings.

RUA6 – OPEN, STOP/SET, CLOSE buttons and L1–L8 LEDs

Level I – ON/OFF

  1. Hold STOP/SET until L1 starts flashing, approximately 3 seconds; then release.
  2. Use OPEN/CLOSE to select the function LED.
  3. Press SET briefly to toggle the state: a short flash = OFF, a long flash = ON.
  4. To exit, wait 10 seconds without pressing any buttons. The changes will be saved.

LED – function and meaningStatus
L1 – Automatic closing
ON: after opening, the gate closes after the pause set by II/L1; factory setting: 30 seconds. OFF: waits for a command.
OFF – factory setting
ON – enabled
L2 – Close after photocell
After the photocell is cleared, the gate closes after 5 seconds. With I/L1 OFF, the gate opens fully first; with I/L1 ON, opening stops when the photocell is cleared. A STOP command cancels the function for the current manoeuvre.
OFF – factory setting
ON – enabled
L3 – Always close
When power returns, the open gate closes; a 5-second warning is given before movement. With OFF, the gate remains stationary.
OFF – factory setting
ON – enabled
L4 – Standby
One minute after operation ends, BlueBUS and the LEDs switch off, except for the slowly flashing BLUEBUS; a control command wakes the system again.
OFF – factory setting
ON – enabled
L5 – Peak force
ON disables the gradual start and applies peak force. This does not replace correcting excessive friction; measure safe forces after changing the setting.
OFF – factory setting
ON – enabled
L6 – Pre-flashing
ON: a 3-second warning before movement. OFF: the warning light starts flashing when movement begins.
OFF – factory setting
ON – enabled
L7 – CLOSE = partial opening
ON changes both the terminal and radio CLOSE commands to partial opening, as set by II/L6. OFF retains closing.
OFF – factory setting
ON – enabled
L8 – Slave
ON only on the subordinate drive when using Master/Slave. OFF is Master.
OFF – factory setting
ON – enabled

Outside programming mode, the function LED is lit when ON and off when OFF. Flashing L1/L2 or L3/L4 may require device learning; see LED diagnostics.

Level II – Values

  1. Hold SET for approximately 3 s; release when L1 flashes.
  2. Use OPEN/CLOSE to select the parameter input LED.
  3. Press and hold SET again. After approximately 3 s, the LED for the current value lights up.
  4. While continuing to hold SET, select a value using OPEN/CLOSE; then release SET.
  5. Set the next parameter in the same way; to save and exit, wait 10 s without pressing any buttons.

Input LED – name and descriptionSetting LED – value
L1 – Pause duration
Applies when I/L1 is enabled.
L1 – 5 s
L2 – 15 s
L3 – 30 s (factory setting)
L4 – 45 s
L5 – 60 s
L6 – 80 s
L7 – 120 s
L8 – 180 s
L2 – Step-by-step mode
Sequence for P.P. and the corresponding radio command.
L1 – Open → stop → close → stop
L2 – Open → stop → close → open (factory setting)
L3 – Open → close → open → close
L4 – Condominium mode: ignores the next command while opening; reopens while closing
L5 – Condominium mode 2: same as L4; a command lasting more than 2 s stops the gate
L6 – Step-by-step mode 2: a command shorter than 2 s partially opens the gate
L7 – Hold-to-run: movement continues while the command is held
L8 – Semi-automatic opening; closing requires holding the command
L3 – Motor speed
After changing the setting, check stopping, deceleration and safe force levels. Choose a speed suited to the gate; the maximum no-load speed is not a guaranteed speed under load.
L1 – Very slow
L2 – Slow
L3 – Medium
L4 – Fast (factory setting)
L5 – Very fast
L6 – Extremely fast
L7 – Fast opening, slow closing
L8 – Extremely fast opening, fast closing
L4 – S.C.A. output
24 V DC output function / max. 4 W. Radio outputs depend on the receiver.
L1 – Gate-open indicator: off when closed, on when open; flashes slowly while opening and quickly while closing (factory setting)
L2 – Active when the gate is closed
L3 – Active when the gate is open
L4 – Radio output 2
L5 – Radio output 3
L6 – Radio output 4
L7 – Maintenance indicator
L8 – Electric lock
L5 – Motor force
Increasing the force setting does not replace fixing mechanical resistance. The controller also accounts for low temperatures; measure impact forces after changing the setting.
L1 – Lightest – lowest level
L2 – Very light
L3 – Light
L4 – Medium
L5 – Medium-heavy (factory setting)
L6 – Heavy
L7 – Very heavy
L8 – Heaviest – highest level
L6 – Partial opening
The pedestrian opening must be shorter than the learned total travel distance.
L1 – 0.5 m
L2 – 1.0 m (factory setting)
L3 – 1.5 m
L4 – 2.0 m
L5 – 2.5 m
L6 – 3.0 m
L7 – 3.4 m
L8 – 4.0 m
L7 – Maintenance reminder
Number of operations between maintenance intervals. Opening and closing count as two operations; one complete cycle consists of both.
L1 – Automatically based on movement difficulty (factory setting)
L2 – 1,000 operations
L3 – 2,000 operations
L4 – 4,000 operations
L5 – 7,000 operations
L6 – 10,000 operations
L7 – 15,000 operations
L8 – 20,000 operations
L8 – Error history
View the last eight operations; this is not a configurable default value.
L1 – Most recent operation
L2 – Second most recent operation
L3 – Third most recent operation
L4 – Fourth most recent operation
L5 – Fifth most recent operation
L6 – Sixth most recent operation
L7 – Seventh most recent operation
L8 – Eighth most recent operation

Timer and gate held open

A voltage-free P.P. command lasting more than 2 s opens the gate and keeps it open for as long as the command is active, for example from a time switch. The exception is mode II/L2, value L5 “Condominium mode 2”. If a continuous command is unexpected, check the timer or module relay.

Diagnostics and troubleshooting

FLASH may report an error as two identical flash sequences separated by a pause of approximately 1 s. The number of flashes is unrelated to the value LED used in programming.

FlashesCause and next step
1 + 1BlueBUS does not match the learned devices. Check the cables, addresses and status of the photocells; after fixing the issue, repeat the learning procedure.
2 + 2Photocell activation. Clear the beam, clean the optics, and check alignment and the address in the function table.
3 + 3Obstacle detection or excessive resistance. First check the mechanics, then the settings II/L5 and safe forces.
4 + 4STOP activation. Check the edge, contacts and status of the learned input; STOP wiring.
5 + 5Internal parameter error. Wait at least 30 s and try the command again; if the problem recurs, contact service.
6 + 6Maximum number of manoeuvres exceeded. Allow the operator to cool down and adjust operation according to cycles and load.
7 + 7Internal electrical circuit fault. Disconnect all power sources, then restore power after a short while; if the problem recurs, contact service.
8 + 8A continuous command blocks further commands. Check the button, timer and input relays.

LEDs on the control board

IndicationMeaning / check
BLUEBUS – offNo power or a fault; check the power supply and fuses with the power disconnected.
BLUEBUS – regularly flashes once per secondNormal operation. It may briefly flash twice when an input changes.
STOP – litThe learned STOP input is in its normal state. Off = activated or in a different state.
P.P. / OPEN / CLOSE – litA command is active on the corresponding input. If no command is being issued, check for a stuck button or relay.
L1 and L2 flashingRequest to learn devices.
L3 and L4 flashingRequest to learn the travel limits.

How to read the history

  1. Enter level II: press SET for about 3 s and release when L1 lights up.
  2. Select input LED L8. Hold SET for about 3 s until the manoeuvre LED appears.
  3. While holding SET, use OPEN/CLOSE to select the last manoeuvres, L1–L8. The number of flashes corresponds to the error in the table above.
  4. Release SET and wait 10 s.

When a safety device is not working

Have the faulty safety device repaired as soon as possible. Temporary operation is possible only under direct supervision and with the travel path safely clear: after a command is rejected, issue it again within 3 s and keep holding it. After about 2 s, the gate moves while you hold the command; releasing it stops the gate. This is not automatic operation or a substitute for repair. Do not bridge safety inputs for permanent use.

Maintenance and service counter

Carry out maintenance at least every 6 months or 20,000 manoeuvres since the last maintenance, whichever comes first. One opening and one closing count as two manoeuvres. Check more frequently in harsh environments.

  1. Disconnect all power sources, including any backup power supply.
  2. Check the fastenings for tightness and inspect for corrosion and wear on the wheel, rack and gate guide; remove debris from the track and photocell lenses.
  3. After restoring power, repeat the test of the limit positions, photocells, edges and safe forces.
  4. After servicing, record the maintenance and reset the service counter.

Counter statusMaintenance indication
Below 80% of the set limitFLASH operates normally; the maintenance output lights for 2 s at the start of opening.
81–100%FLASH stays lit for 2 s at the start; the maintenance indicator flashes while the gate is moving.
Above 100%FLASH lights for 2 s at both the start and end; the maintenance indicator flashes continuously.

Reading and resetting the service counter

Set the limit using II/L7. To read the counter, press SET for about 3 s, select L7, then hold SET for a further 3 s or so. Briefly press OPEN/CLOSE while still holding SET and count the flashes: one flash represents 10% of the set limit. Then release SET.

Reset after maintenance: with L7 selected and SET still held, press OPEN + CLOSE simultaneously for at least 5 s. When the rapid flashing confirms the reset, release the buttons. Wait 10 s for the process to finish. This is a maintenance counter only; it does not delete transmitters or replace device or travel-limit learning.

Relearning and receiver memory

After changing the wiring, repeat the relevant learning procedure. Clear the radio memory according to the specific receiver. Do not use the service-counter reset procedure as a universal control unit reset.

Manual release

Release the gate only when it is stationary. Disconnect the power supply and secure the gate leaf against unintentional movement. When releasing the gate, you are handling its full weight.

  1. Slide the lock cover aside.
  2. Insert the key and turn it clockwise.
  3. Pull out the release handle and move the gate by hand.
  4. To re-engage the drive, reverse the procedure. Before operating electrically, check that the gearbox has re-engaged.

NICE RUN1200HS – key and manual release

RUN1200HS backup power supply

The RUA6 has a dedicated connection for the PS524 charger and two compatible batteries B12-B, each 12 V. Connect the backup power supply according to the instructions for this kit, not to the 100 mA auxiliary output and not in place of BlueBUS. Do not confuse it with the PS124 backup power supply.

The backup power supply consists of a charger for RUN1200HS and 2 × B12-B 12 V / 6 Ah battery. Choose parts intended for this kit and, when replacing them, check the type and connectors of the original parts. Test the backup power supply on the specific gate; the number of openings depends on the condition of the batteries and the load.

NICE RUN1200HS technical specifications

ParameterValue
ApplicationOne sliding gate leaf
Control unitRUA6
Mains power supply230 V AC / 50 Hz
Motor24 V DC
Max. gate leaf weight / length1 200 kg / 14 m
Limit switchElectromechanical
Catalogue no-load speedApprox. 0.37 m/s (22 m/min)
Rated speed19 m/min
Max. force / torque790 N / 28.4 Nm
Catalogue power consumption / current415 W / 2 A
Peak power consumption / current550 W / 5.2 A; size the supply cable and protective devices according to the nameplate
Catalogue operating cycles60 cycles/h
Operating cycle limitAccording to the length and weight tables; the catalogue figure is not a universal limit.
Continuous operation under rated conditions60 min at 20 °C; max. 10 min at 50 °C
Gear18 teeth, module 4
Auxiliary output24 V DC, −30% / +50%, max. 100 mA total
S.C.A.24 V DC, max. 4 W
BlueBUSMax. 15 load units
Protection rating / temperatureIP44 / −20 to +50 °C
Motor weight24.5 kg
Dimensions400 × 255 × 387 mm (catalogue); see the drawing below for installation dimensions.

Catalogue values and values under peak or rated load describe different operating conditions; use the nameplate and peak load when sizing the supply cable. The dimensions in the original installation drawing are in mm. The drawing retains the dimensions, including the position of the gear.

NICE RUN1200HS – original installation dimensions in mm

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE RUN1200 HS – high-speed operator for sliding gates (A)

Product: NICE RUN1200 HS – high-speed operator for sliding gates (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.