NICE S-Fab SFAB2124 – standalone underground operator for a swing gate leaf up to 2.3 m / 400 kg
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€360.81 including VAT
| Weight |
|---|
| 6,00 kg |
Description of NICE S-Fab SFAB2124 – standalone underground operator for a swing gate leaf up to 2.3 m / 400 kg
NICE S-FAB SFAB2124 is a standalone underground operator with a 24 V DC motor and magnetic encoder for one gate leaf. It is a non-reversible operator. It does not include a control unit; for a new setup, use MC824HR30. A double-leaf gate requires two motors and one compatible control unit.
The underground design keeps the operator hidden beneath the hinge axis. It is useful when there is no room beside the gate leaf for a linear actuator or articulated-arm operator, or if you want to preserve the gate’s clean appearance. Voltage 24 V is the motor voltage; mains power and accessory functions are provided by the control unit.
Control unit and compatible accessories
The SFAB2124 has an encoder and is compatible with the MC824H control system. The MC824L is not a replacement for the MC824H with this motor. For an older MC824HR10, follow the wiring instructions and procedures for the board actually installed.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors. Wiring. |
|
| Flashing light | Indicates gate movement. The control unit determines the power supply and permitted current draw; output specifications. |
Other warning lights select according to the voltage and maximum current draw of the FLASH output on the control unit actually installed. |
| Photocells | Protect the passage area according to the position and operating mode. Wiring and setup. |
Connect wired BlueBUS pairs to BLUEBUS. EPMOW units require an IBW radio interface connected to BlueBUS; they are not wired directly like EPMB units. With FT210B, the transmitter on the gate leaf is battery-powered, while the receiver connects to BlueBUS with two wires. FT210B also transmits the status of the safety edge. Relay photocells connect to contact inputs, not to BlueBUS. |
| Transmitter | Remote control. The coding type must match the receiver installed; pairing. | |
| Receiver | Receiver for the SM control unit connector. OXIBD and OXILR use different radio systems; select transmitters to match the receiver. |
|
| Antenna | Improved remote-control reception. Connect the antenna to the installed receiver; for the OXIBD, connect it directly to its antenna terminals. | |
| Keypad | Code access. The radio model must match the receiver, and the wired model must match the interface type. | |
| Key switch | Key-operated control via a volt-free NO contact connected to the step-by-step, open or close input. | |
| Electric locks | Additional leaf locking; lock output. |
|
| Card readers | Chip or card access via a compatible control unit interface. |
|
| Backup power supply | Operation during a power outage. Choose the battery to match the control unit generation and connector. |
For MC824HR30 NICE PSS324. The older PS324 requires the correct cable CABLA11 and the corresponding configuration; backup power connection. |
Standalone motor, box and gate hardware
| Part of the kit | What you need |
|---|---|
| SFAB2124 motor | One motor with a magnetic encoder and a 2 m power cable. The limit applies to one gate leaf. |
| Foundation box | SFABBOX made of cataphoretically coated steel, with a lever for attaching the gate leaf and mechanical stops. Select the box separately according to the options included in the order. |
| Control unit and safety devices | MC824HR30, compatible photocells, controls and signal lights, depending on the configuration. These components are not built into the motor. |
| Manual release | Access to the openings in the cover is required from both sides, along with a suitable triangular key. After installation, the manual release must be easily and safely accessible. |
The box can be used with either a right-hand or left-hand gate leaf. When buying a kit, check the number of motors and boxes, the specific control unit and the included equipment; two motors do not increase the maximum permitted weight of a single gate leaf.
Limits on length, weight and operation
The maximum values of 2.3 m and 400 kg do not apply simultaneously. The combination of gate-leaf length and weight must remain within the permitted area of the graph. The shape and height of the gate leaf, solid infill and strong winds can significantly reduce the permitted load.
| Length of one gate leaf | Maximum weight according to the graph |
|---|---|
| 1.5 m | 400 kg |
| 1.8 m | 330 kg |
| 2.0 m | 300 kg |
| 2.3 m | 250 kg |
Movement must be smooth and meet similar resistance along the entire travel path; the gate leaf must not move on its own when released. As a guide, opening to 90° under the rated load takes approximately 15 seconds, excluding acceleration and deceleration. With no load, the motor runs at 1.25 rpm; at rated torque, it runs at 1 rpm.
For opening to 90°, the stated rate is 60 cycles per hour under the rated load. When opening to 180°, this figure must be halved, to 30 cycles/h. The actual number also depends on the gate as a whole and the operating conditions.
Estimated service life
First check that the combination is permitted in the limits graph; the index table does not replace this limit. Then select the index for the gate-leaf weight and length. Add the relevant environmental factors, then read the estimated number of cycles from the graph. A dash indicates a combination that is not permitted. The estimate assumes regular maintenance and does not guarantee service life.
| Performance of the complete automation system | Index | Service life graph | |||
|---|---|---|---|---|---|
| Gate-leaf weight | 1.50 m | 1.51–1.80 m | 1.81–2.00 m | 2.01–2.30 m | |
| Up to 100 kg | 0% | 10% | 20% | 30% | |
| 101–250 kg | 10% | 20% | 30% | 40% | |
| 251–300 kg | 20% | 30% | 40% | 50% | |
| 301–330 kg | 30% | 40% | 50% | — | |
| 331–400 kg | 40% | 50% | — | — | |
| Additional factor | Add | ||||
| Temperature above 40 °C or below 0 °C, or humidity above 80% | 15% total for this row | ||||
| Solid gate-leaf infill | 15% | ||||
| Windy location | 15% | ||||
For a gate leaf shorter than 1.50 m, ask a technician to confirm the service-life index; the permitted weight is still determined by the limits graph above.
Installing the foundation box and gate leaf
The box pin and all hinges must share the same axis. Misalignment creates resistance and puts strain on the mechanism; it cannot be corrected by increasing the force setting. Before installation, check the box dimensions, gate-leaf height, clearance for the covers and access for manual release. How to install the underground box.
- Prepare a foundation pit to suit the box. Install a separate cable conduit and a functioning drainage pipe; water must not accumulate in the box.
- Position the box so that its axis is exactly beneath the axis of the upper hinge. Set it in concrete, level and at the correct height.
- Prepare three M10 threaded holes, at least 15 mm deep, in the underside of the gate leaf and fasten the lever with three screws. A sufficiently strong weld is an alternative.
- Grease the box bushing and insert the lever attached to the gate leaf. The gate leaf must be securely fastened in its hinges and prevented from lifting.
- Set the stops. Place the motor in the box and loosely tighten the fasteners so that it sits slightly raised above the bottom.
- Move the gate leaf slowly so the gearing engages correctly with the motor; only then fully tighten the fastening screws.
- Route the cable out of the box through the conduit. Fit covers A, B and C in the order shown in the illustration and fasten them with the supplied screws.
The motor has a metal housing and an IP67 IP67 rating that protects the motor during temporary immersion; it does not replace drainage or regular cleaning of the box. Electrical connectors must not be placed in the box.
Stops and opening angle
Mechanical stops limit both opening and closing. The internal stops allow you to set the opening angle to 90° ±10° or 180° ±10°; if you use custom external gate stops, check their position and the resulting angle against the specific mechanical assembly. An external stop alone does not confirm that any given angle is suitable. The angle is not adjusted simply by changing the control unit's learning time. The internal stops cannot be freely adjusted across the entire range between 90° and 180°.
Tighten the locknuts after adjusting the stops. Manually check both end positions, that the movement path is clear, and that the fixing is secure; only then teach the positions on the control unit.
Motor and magnetic encoder wiring
The power cable is 2 m. For longer distances, use a suitable junction box outside the box; joining cables inside the foundation box is prohibited. Disconnect both the mains supply and the battery before wiring.
| SFAB2124 motor cable | Connection |
|---|---|
| Blue and brown | 24 V DC power pair to the M terminals of the corresponding motor. The control unit determines the direction; there is no permanently fixed +/−. |
| Black and grey | ENC input for the corresponding gate leaf. On the MC824H, encoder polarity is not relevant; the pair must belong to the same motor. |
| Yellow-green | Protective earth (PE); never use it as a motor or encoder wire. |
On the MC824HR30, the motor cable, including PE, must have a cross-section of 3 × 1.5 mm², and the encoder cable 2 × 1.0 mm²; both the motor and encoder cables should be no longer than 10 m between the control unit and the motor. Connect a single gate leaf to M2 and ENC2. For the complete terminal layout and wiring, see the MC824HR30 manual.
MC824HR30 accessory terminals and power supply
| Connection | Voltage, polarity and limit |
|---|---|
| Auxiliary power supply | + is the left terminal of the SbS pair; − is the right terminal of the STOP pair, when viewing the terminal blocks with the STOP and SbS labels readable, as shown in the picture. 24 V DC −30/+50%, up to 200 mA in total. |
| BlueBUS | Two wires for compatible EPMB and other devices. Non-polarized; this is not a universal 24 V output. The devices must be recognized again when they are changed. |
| FLASH | 12 V DC, up to 21 W, for example ELDC. The auxiliary 24 V power terminals must not be confused with the FLASH output. |
| ELS | 12 V AC, up to 15 VA for an electric lock; no +/− polarity. |
| OGI | Gate-open indicator: 24 V, up to 4 W. The function depends on the output setting. |
| SbS / OPEN / CLOSE | Control voltage-free NO contact; do not apply external voltage to command inputs. |
| STOP | Safety input for the selected device: NO/NC contact or 8.2 kΩ resistive edge. Wiring and recognition must match the actual control board. |
Connect only devices that match the voltage and current draw of the specific output. Select radio receivers, the battery and solar power according to the control unit's connectors; detailed accessory power supply.
Initial start-up and gate check
Before switching on, the gate must move freely by hand along its entire path, the box must be drained, the stops adjusted and the drive engaged. Check the protective earth conductor, cable routing, photocells and protection of hazardous areas.
- Disconnect both the mains supply and any battery, then check all connections; there must be no electrical joints inside the box.
- Restore the power supply. On the specified current control unit, the BlueBUS LED should flash regularly once per second, the TX/RX photocell LEDs should flash, and the FLASH warning light should remain off. If the status is incorrect, disconnect the power supply and fix the cause.
- Recognize the connected devices, then teach the gate-leaf positions on the control board actually installed.
- Check the direction of movement, both end positions, deceleration and the correct sequence for overlapping gate leaves.
- Test each safety device in its operating position and measure the forces across the entire gate.
- Hand over the manual release mechanism, keys, manual and inspection schedule. Use the gate only after the complete assembly has passed testing.
For a single gate leaf on the MC824HR30, use M2 and its encoder; leave M1 unused. For a double-leaf gate, always assign the motor and encoder to the same leaf. For overlapping gate leaves, M2 opens first and closes last. Before teaching, confirm the position of the motor selector for the SFAB2124 on the actual control board; do not select it solely based on a similar name for another motor.
Recognizing connected devices
On the specified current control unit, press and hold OPEN ▲ and STOP/SET for approximately 3 seconds. Release them when L1 and L2 start flashing rapidly. Wait for the process to finish: the STOP LED will stay lit and L1/L2 will go out. This procedure must also be performed with no devices connected and repeated after any devices are added or removed.
Automatic position learning
On the MC824HR30, after recognizing the devices and checking the selector, press and hold CLOSE ▼ and STOP/SET for approximately 5 seconds; release them when L3/L4 flash rapidly. For a double-leaf gate, the sequence is: slow closing of M1, slow closing of M2, slow opening of M2 and M1 with a controlled delay, then fast closing of both. L3/L4 go out when the process is complete. For a single-leaf gate, only M2 is used; follow the procedure for a single-leaf setup in the control unit manual.
For a double-leaf gate, M1 must close first. If M2 moves instead, stop the learning process using the OPEN or CLOSE button. After disconnecting both the mains supply and the battery, swap the M1/M2 assignments on the control unit along with their encoders, then repeat the learning process.
If the first movement is in the wrong direction, stop the learning process immediately using the OPEN or CLOSE button. Correct the wiring only after disconnecting the power supply, then repeat the learning process. Activation of a photocell or STOP input will interrupt learning and L1 will start flashing; fix the cause and start again. Older control boards may use a different procedure.
Control unit settings, transmitters and maintenance
| What you need to set | Procedure on the relevant control unit |
|---|---|
| Device learning | Device learning |
| Position learning | Position learning |
| Automatic closing and pause | Automatic closing and pause |
| Motor force | Motor force |
| Remote control pairing | Remote control pairing |
| Battery and its connector | Battery and its connector |
| Control unit diagnostics | Control unit diagnostics |
Do not try to fix sticking hinges or a flooded box by increasing the force setting. After changing the positions, stops or force setting, check safety again. Deleting remote controls and resetting the control board are different procedures; follow the instructions for the actual control unit.
When the drive does not work properly
| Symptom | What to check |
|---|---|
| The gate leaf is difficult to move even when disengaged | Hinges, alignment of the box, deformations and stops. First eliminate the mechanical cause; installation. |
| Water is standing in the box | Disconnect the power supply. Clean and check the drainage; maintenance. Have damaged electrical components inspected before using the system again. |
| The motor does not start or stops | Check the power supply and fuses at the control unit, the STOP and photocell status, and the fault indicators. Do not bypass safety devices; diagnostics. |
| The motor runs, but the gate leaf does not move | Check whether the manual release is engaged and whether the motor is mechanically connected to the gate leaf. Releasing and returning to operation. |
| The gate leaf moves in the wrong direction | After disconnecting the power supply, check the motor wires and repeat the position-learning procedure; motor wiring. |
| Only the radio remote control is not working | Check the transmitter battery, coding compatibility, antenna, and whether the button is programmed to the correct receiver. |
Maintenance and safe use
Carry out an inspection at least every six months, more often in demanding conditions, in accordance with the maintenance schedule. Before servicing, disconnect the mains and backup power supply, and secure the gate leaf against movement.
- Clean the box and drainage; water and dirt must not obstruct the mechanism.
- Check the mounting of the motor, gate leaf and stops, as well as the condition of the cables and manual release.
- Check lubrication of the mechanical contact points according to the installation instructions.
- Repeat the manual travel test and test the photocells and other safety devices.
- Measure the forces and carry out any necessary repairs; do not use a damaged assembly.
The gate must remain under supervision while moving. Keep remote controls out of children's reach, do not enter the travel path, and use the safe manual release in the event of a fault. If the gate leaf has a pass-through gate, opening it must prevent the drive from operating.
Manual release in the event of a power failure
- Switch off the power supply and secure the gate leaf against unintended movement.
- Insert the triangular key into one of the two side openings in the top cover.
- Turn the key 180° in either direction and move the gate leaf by hand.
- To restore operation, insert the key again and turn it 180°. The drive will re-engage when the control unit receives its first command; check that it operates safely.
Technical specifications and dimensions
| Parameter | SFAB2124 |
|---|---|
| Motor | 24 V DC, magnetic encoder; control unit not included |
| Maximum / rated torque | 250 / 120 Nm |
| Peak / maximum current | 5 / 2 A |
| Peak / maximum power | 120 / 50 W |
| Speed at no load / at rated torque | 1.25 / 1 rpm |
| Operation | 60 cycles/h at 90°; half that at 180° |
| Ingress protection and temperature | IP67; −20 to +50 °C |
| Motor dimensions only | 235 × 206 × 96.5 mm |
| Motor weight only | 6 kg; the weight of the box and equipment is assessed separately |
| Cable | 2 m supply cable included |
| Foundation box | SFABBOX; width 320 mm, box height 81 mm, protruding section as shown in the drawing: 52 mm |