NICE Run RUN1500P – standalone drive for sliding gates
| Product availability: | for the question | The product may not be available, contact us for more information. |
|---|
for the question
€795.17 including VAT
| Weight |
|---|
| 12 kg |
Description of NICE Run RUN1500P – standalone drive for sliding gates
NICE RUN1500P is a standalone non-reversible drive for a sliding gate with a leaf weighing up to 1,500 kg and measuring 14 m. The motor is 24 V DC, with a mains supply of 230 V AC. It has a built-in RBA3R10 control unit and inductive limit switch.
RUN1500P detects the end positions without a mechanical lever. The standalone motor differs from the kit: choose the radio receiver, remote control, photocells, warning light and rack according to the equipment you need.
Accessories and control unit
The standalone drive includes the control unit. For a complete automation system, add a rack, controls and safety devices suited to the specific gate.
| What | Why | Type |
|---|---|---|
| Control unit | For drive setup and servicing; when replacing the board, check the marking on the installed board. | |
| Warning light | Indicates movement. The FLASH output is low voltage. | |
| Photocells | They detect obstacles in the protected area. They do not replace an assessment of all gate-related risks. | |
| Transmitter | Choose remotes according to the receiver and radio coding family. | |
| Receiver | Without a receiver, the standalone motor cannot receive radio commands. NICE receivers. |
|
| Mobile control | Distinguish between drive setup and day-to-day operation. Wi-Fi relay modules connect using a potential-free contact. |
|
| Antenna | Improves reception when positioned appropriately. The antenna does not power the warning light. |
|
| Keypad | Entry without a separate remote control. | |
| Key switch | Key-operated control via a potential-free contact. | |
| Card readers | Access using a card or key fob. |
|
| Rack | Transfers movement from the pinion to the gate leaf. Choose the type based on the load and mounting method. | |
| Backup power supply | Provides limited operation during a power outage. |
|
Current replacement board: RBA3R10. Older RBA3 has been replaced. For an existing installation, check the actual control board and connectors; the RUN family designation alone does not mean all models use the same control system.
RUN1500P standalone drive equipment
RUN1500P is supplied as a standalone motor with control unit. Select the radio receiver, remote controls, photocells, warning light and rack to suit the specific gate. Agree on the kit configuration when placing the order.
Drive features
- Durable aluminium-alloy body with epoxy coating and impact-resistant cover.
- BlueBUS with two-wire connection and support for addressed photocells.
- Adjustment of speed, force and pause; optional automatic closing.
- The control unit compensates for temperature and limits the number of manoeuvres in the event of overload. The force reserve must still be checked mechanically.
- Diagnostics via warning light and LEDs, memory for the last eight manoeuvres and a service counter.
- Master/Slave for two sliding gate leaves moving in opposite directions.
Drive selection and operating limits
RUN1500P is designed for one sliding gate leaf weighing up to 1,500 kg and measuring up to 14 m. Weight, length and resistance to movement must be considered together. The maximum weight rating does not mean that every 1,500 kg gate should be operated at the highest speed.
| What to check | Limit / condition |
|---|---|
| Gate leaf weight | Up to 1,500 kg; the number of cycles and permitted speed decrease as the weight increases. |
| Gate leaf length | Up to 14 m; length determines the base number of cycles. |
| Starting | The required force must be less than half of 1,000 N, i.e. less than 500 N. |
| Smooth movement | The required force must be less than half of 560 N, i.e. less than 280 N along the entire travel path. |
| Reserve | NICE recommends a 50% force reserve to account for increased friction in adverse weather. |
For a typical selection, we recommend allowing a margin in both dimensions and weight, aiming for around 80% of the maximum values. This is a selection aid, not a substitute for measuring the required force or checking wind, ice and the cycle table. The gate leaf must slide smoothly by hand and must not start moving on its own.
Number of cycles by length
| Gate leaf length | Cycles/h | Consecutive |
|---|---|---|
| Up to 4 m | 60 | 30 |
| Over 4 to 6 m | 40 | 20 |
| Over 6 to 7 m | 34 | 17 |
| Over 7 to 8 m | 30 | 15 |
| Over 8 to 10 m | 20 | 12 |
| Over 10 to 12 m | 20 | 10 |
| Over 12 to 14 m | 17 | 8 |
Reduction by weight
| Gate leaf weight | Cycle percentage | Maximum speed |
|---|---|---|
| Up to 200 kg | 100% | V6 |
| Over 200 to 400 kg | 100% | V6 |
| Over 400 to 500 kg | 95% | V6 |
| Over 500 to 600 kg | 90% | V5 |
| Over 600 to 700 kg | 85% | V5 |
| Over 700 to 800 kg | 80% | V5 |
| Over 800 to 900 kg | 75% | V5 |
| Over 900 to 1,000 kg | 70% | V4 |
| Over 1,000 to 1,200 kg | 65% | V4 |
| Over 1,200 to 1,350 kg | 60% | V3 |
| Over 1,350 to 1,500 kg | 55% | V3 |
Multiply the values in the first table by the percentage in the second, and do not exceed the result. One cycle means opening and closing. Example: 5 m / 650 kg gate leaf: 40 × 0.85 = 34 cycles/h, 20 × 0.85 = 17 consecutive, maximum V5. Continuous operation is limited to 10 minutes. At high temperatures, the protection system may further limit the number of movements. Speed adjustment.
Approximate service life
Add the indexes for length, weight, and relevant conditions. Find the total on the horizontal axis of the graph and read off the approximate number of cycles. The result is an estimate assuming regular maintenance, not a guarantee of service life or a number of years.
| Properties of the complete automation system | Index | Service life graph |
|---|---|---|
| Length under 6 m | 5% |
Horizontal axis: index in %. |
| 6 to 9 m | 10% | |
| 9 to 12 m | 15% | |
| 12 to 14 m | 20% | |
| Weight 100 to 200 kg | 5% | |
| 200 to 400 kg | 10% | |
| 400 to 600 kg | 20% | |
| 600 to 800 kg | 30% | |
| 800 to 1,000 kg | 40% | |
| 1,000 to 1,200 kg | 50% | |
| 1,200 to 1,500 kg | 60% | |
| Above 40 °C / below 0 °C, or humidity above 80% | 20% | |
| Dust, sand, or salinity | 15% | |
| Speed higher than L4 “fast” | 15% |
Example: 6.5 m / 450 kg in a dusty environment: 10% + 20% + 15% = 45%, approximately 200,000 cycles on the graph. If a value falls on the boundary between ranges, use the higher index for a conservative assessment. Do not extrapolate the graph beyond its plotted range. The drive must not be installed in an acidic, saline, or explosive atmosphere; the salinity row in the table does not permit such use.
Installing the drive and rack
Before carrying out any work, disconnect the mains and any battery or solar power supply. The gate must have sturdy mechanical end stops, anti-derailment protection, and sufficiently strong guides. The drive limit switch does not replace the gate’s mechanical stop.
- Check that the gate moves smoothly by hand along its entire travel and the force limits required. Protect against trapping hazards, including at the rear of the sliding gate leaf.
- Choose a solid, level foundation outside any flood-prone area. Keep the key and cover accessible. Install cable conduits so that they do not channel water into the drive.
- Position the anchor plate parallel to the gate, as shown in the original drawing. The anchor thread should extend approximately 30–40 mm above the plate. Allow the concrete to cure completely before tightening.
- Install the drive and align it with the gate leaf. After installing the rack, tighten the fasteners and cover the nuts with the supplied caps.
Gear rack – module 4
The pinion has module 4, 18 teeth. The rack must have the same module and a load rating suitable for the gate leaf. The gate’s weight must not rest on the pinion. Choose nylon and steel versions according to the specifications of the particular rack, not just because the module matches.
- Release the motor and position the gate leaf at least 50 cm from the closed end position when installing the rack.
- Attach the rack to the gate leaf with suitable brackets; maintain a gap between the rack and pinion along the entire travel of 1–2 mm.
- When joining rack sections, maintain consistent tooth spacing. Move the gate through its full travel by hand and check the alignment; according to the manufacturer, lateral misalignment must not exceed 5 mm.
- After tightening, check again that the gate moves freely, that the clearance is correct, and that the limit switches work.
End positions – variant differences
The RUN1500P has an inductive limit switch. It detects the end-position targets without mechanically pressing a lever. When installing, set the sensing targets according to the supplied RBA1 assembly so that they respond reliably in both directions before the mechanical stops. Adjust the inductive sensing targets for this drive.
Before programming, set the opening direction using the switch on the control board, according to the drive orientation. Disconnect all power supplies before changing the direction. After teaching the travel limits check that deceleration begins approximately 50–70 cm before the end and that the gate stops approximately 2–3 cm before the mechanical stop. Verify the actual position by testing both directions.
Wiring
| Purpose | Cable and maximum length |
|---|---|
| Mains power supply | 3 × 1.5 mm² up to 30 m. For longer runs, use 3 × 2.5 mm² and provide protective earthing at the automation system as required by the specific installation. |
| Flashing light | 2 × 0.5 mm²; 20 m. |
| Antenna | RG58; maximum 20 m, recommended length under 5 m. |
| BlueBUS / photocells | 2 × 0.5 mm² up to 30 m; for runs over 30 m and up to 50 m, use 2 × 1 mm². |
| Fixed safety edges | 2 × 0.5 mm²; 30 m, connection according to STOP type. |
| Moving safety edge | 2 × 0.5 mm²; 30 m; use a suitable device for transmission to the moving gate leaf, e.g. FT210B. |
| Key switch | Two 2 × 0.5 mm² cables or one 4 × 0.5 mm² cable; 50 m. |
Use cables suitable for the environment in which they will be installed. Leave approximately 20–30 cm of spare cable inside the drive and secure the cables so they cannot be pulled out of the terminals. The mains supply cable must have a protective conductor and provision for complete, safe disconnection.
Wiring and orientation on the control board
The drive supply is 230 V AC; the motor itself is 24 V DC. Do not connect mains voltage to the low-voltage terminals or BlueBUS. The board has OPEN, STOP/SET and CLOSE buttons, LEDs L1–L8, an SM receiver connector, and a BusT4 interface via IBT4N.
Wiring diagram
FLASH = warning light; OGI = programmable output; TX/RX = photocell transmitter and receiver; Aerial = antenna; Receiver = remote-control receiver; Selector = direction selector. The terminal labels are the same as those on the board.
| Terminal | Connection and important condition |
|---|---|
| FLASH | Output for one or two warning lights with 12 V bulbs, up to 21 W, according to the manufacturer's wiring instructions. For LED equipment, use a compatible ELDC. Warning light and antenna. |
| OGI | 24 V DC (−30% / +50%), up to 4 W; the function is determined by II/L4. The factory setting is radio output 3, not automatically an open-gate indicator. The +/− order for this output is not shown in the diagram; do not infer it from the auxiliary power supply. |
| BlueBUS | Two-wire power supply and communication for compatible accessories. Photocells are connected in parallel with no polarity. |
| STOP | NO, NC or 8.2 kΩ safety input; the type is identified during learning. A change of state stops movement and briefly reverses it. |
| SbS | Step-by-step command via a volt-free NO contact; operation according to II/L2. |
| OPEN | Opening via a volt-free NO contact. |
| CLOSE | Closing via a volt-free NO contact. If I/L7 ON, it is a partial opening. |
| Aux In | Auxiliary input, factory-set as NC with STOP function. Reprogramming via Oview. This is not an accessory power output. |
| ANTENNA / Aerial | Connect the coaxial cable's centre conductor and shield as shown in the original diagram; this is not a +/− power connection. |
Auxiliary power supply – specific polarity
With the connector oriented as shown in the following image: right-hand terminal of the STOP pair = negative (−), left-hand terminal of the SbS pair = positive (+). The auxiliary output is 24 V DC, −30% / +50%, maximum total current 100 mA. On the accessory, connect + to the power supply + and − to the power supply −; its NO/COM control contact remains separate.
This pole order applies to this auxiliary power connection only. Do not apply it to FLASH, OGI, the antenna or BlueBUS. A module with higher power consumption must have a suitable separate power supply; connect its volt-free contact to SbS. Aux In is not used for power.
ELDC warning light and antenna
ELDC has a low-voltage light input of 12–36 V DC; connect it to FLASH. The detail below distinguishes the light terminals from the antenna terminals. Do not connect 230 V to the light terminals. In the wiring shown, the manufacturer does not specify the +/− order of the light terminals; do not use the polarity of the STOP/SbS auxiliary output for them.
Antenna
Connect the ELDC antenna or ABFKIT using a separate RG58 cable to the antenna input: centre conductor to the signal symbol, braid to the shield symbol, as shown in the diagram. Do not connect the antenna wires to the power terminals. The antenna must match the receiver frequency.
Key switch, relay and command inputs
SbS, OPEN and CLOSE require volt-free NO contacts. With EKS or a relay module, connect COM and NO of the selected contact to the pair of terminals for the corresponding input. The contacts have no +/− polarity. Do not supply power to the inputs from the module. With a permanently closed OPEN contact, the gate may remain open as it would with a timer; do not disconnect the drive's mains supply for this purpose.
STOP and safety edge
| Device type | Wiring principle |
|---|---|
| NO contacts | In parallel. |
| NC contacts | In series. |
| Two 8.2 kΩ safety edges | According to the manufacturer, they may be connected in parallel; for more than two, use a cascade with a single 8.2 kΩ termination resistor. |
| NO / NC combination | Parallel branches, with an 8.2 kΩ series resistor in the NC branch, according to the approved wiring diagram. |
Volt-free contacts and passive resistive safety edges have no power supply +/−. An electronic safety edge may require its own power supply – check its instructions. After every wiring change, perform device learning and a safety test. NO/NC wiring alone does not provide the same fault diagnostics as a resistive safety edge. Do not bridge the safety input to clear a fault.
BlueBUS photocells
For example, EPMB: connect both TX and RX devices in parallel to the same two BlueBUS wires. There is no positive or negative polarity. TX and RX in a pair must have the same jumpers and address; assign another supported address to the next pair. After adding or removing a device, repeat the learning procedure.
| Pair address | Protected movement / location |
|---|---|
| PHOTO | Outer pair, approximately 50 cm; stops and reverses movement during closing. |
| PHOTO II | Outer pair, approximately 100 cm; closing protection. |
| PHOTO 1 | Inner pair, approximately 50 cm; closing protection. |
| PHOTO 1 II | Inner pair, approximately 100 cm; closing protection. |
| PHOTO 2 | Outer pair for protection during opening. |
| PHOTO 2 II | Inner pair for protection during opening. |
| PHOTO 3 | Pair covering the entire movement area; when used together with PHOTO II, TX/RX must be positioned correctly relative to each other. |
The exact jumper settings are shown on the card EPMB – jumper table. After setting, check optical alignment and the response of each pair in its protected direction. For a standard safety configuration, do not turn a pair into an opening command by cutting link A.
EPMOW requires IBW and is not a substitute for a wired pair without additional equipment. FT210B with a battery-powered transmitter on the moving gate leaf transmits the status of the resistive safety edge to BlueBUS; its wiring and addressing are described in the FT210B instructions.
Initial startup and learning
- Check the installation, limit switches, grounding and wiring. The gate leaf must be approximately halfway along its travel, and the motor must be locked.
- Connect the power supply. BlueBUS should flash approximately once per second, and the TX/RX photocells should indicate activity; FLASH and OGI should be off. If an error occurs, disconnect the power and check the wiring.
- Run device learning, then travel learning, and finally perform the tests. The entire area must be clear while the gate is moving.
Device learning – OPEN + STOP/SET
- Press and hold OPEN and STOP/SET for about 3 seconds.
- When L1 and L2 start flashing rapidly, release the buttons.
- Wait for the process to finish. The STOP LED must be lit, and L1/L2 must stop indicating that learning is in progress. L1–L8 then indicate the function statuses.
Perform this step even if no safety accessories are connected. If L1/L2 are flashing, recognition is not complete; do not proceed to travel learning without checking.
Travel learning – CLOSE + STOP/SET
- After successful device recognition, press and hold CLOSE and STOP/SET for about 3 seconds.
- Release the buttons when the motor starts. The first movement should be opening. If it closes, press STOP/SET, disconnect the power, correct the direction switch setting, and repeat the procedure.
- The drive opens the gate to the limit switch and then closes it. Wait for the entire learning process to finish and watch for any diagnostics.
- Perform several complete opening and closing cycles. Check deceleration and the end positions, and make sure the motor does not press against a fixed stop.
Testing and handover
- Check that the installation is secure and test the manual release. During testing, the gate leaf must be movable by hand in both directions with a force of no more than 390 N; it must also meet the stricter required-force criteria for selecting the drive.
- Test each photocell pair and the safety edge individually. When the status changes, BlueBUS indicates this with two quick flashes; also check that the gate responds correctly.
- Have the forces measured by a qualified professional after adjusting sensitivity and after any change that could affect safety. Meeting the weight limit and having photocells alone is not sufficient.
- Provide the instructions, documentation for the complete automation system, release instructions and maintenance schedule. Do not hand over the gate with safety testing incomplete.
Control unit programming
OPEN / CLOSE scroll through the LED selection; STOP/SET confirms or, when held, opens the programming menu. In normal operation, they are used to open, stop and close the gate. Change settings only when the gate is stationary. Repeat the test after changing force, speed or the behavior of safety devices.
Level I – enabling and disabling functions
- Hold STOP/SET until L1 starts flashing, approximately 3 seconds; then release.
- Use OPEN or CLOSE to select the function LED.
- Briefly press STOP/SET. A short flash indicates OFF; a longer flash indicates ON.
- If desired, change another function. If no button is pressed for approximately 10 seconds, programming ends and the changes are saved.
| LED – function and meaning | Status |
|---|---|
| L1 – Automatic closing ON: after opening, the gate closes after the pause set in II/L1. OFF: automatic closing disabled. | Factory setting: OFF ON = enabled OFF = disabled |
| L2 – Closing after photocell activation ON: the gate closes 5 s after the photocell is cleared. If automatic closing is disabled, the gate first completes opening; if it is enabled, clearing the photocell may shorten the opening time. STOP cancels this sequence. | Factory setting: OFF ON = enabled OFF = disabled |
| L3 – Always close ON: after power is restored, the control unit detects if the gate is open and starts closing after a 5 s pre-warning flash. OFF: this recovery function is disabled. | Factory setting: OFF ON = enabled OFF = disabled |
| L4 – Standby ON: about one minute after movement ends, BlueBUS and the indicators switch off, except for the slow BlueBUS flashing; operation resumes when a command is received. Useful for battery or solar power. | Factory setting: OFF ON = enabled OFF = disabled |
| L5 – Starting peak force ON: applies maximum force at startup instead of gradual acceleration. After startup, II/L5 applies. OFF: gradual startup. | Factory setting: OFF ON = enabled OFF = disabled |
| L6 – Pre-flashing ON: the warning light flashes for 3 s before movement begins. OFF: it starts flashing when movement begins. | Factory setting: OFF ON = on OFF = off |
| L7 – CLOSE as partial opening ON: the CLOSE input controls partial opening according to II/L6. OFF: the CLOSE input closes the gate. | Factory setting: OFF ON = on OFF = off |
| L8 – Slave mode ON: slave motor in a pair; commands and movement are controlled by the Master. OFF: standalone / master control. | Factory setting: OFF ON = on OFF = off |
Level II – parameter values
- Press and hold STOP/SET until L1 flashes, then release. Use OPEN/CLOSE to select the parameter input LED.
- Press and hold STOP/SET again. After about 3 seconds, the value LED lights up.
- Keep holding STOP/SET and use OPEN/CLOSE to select the value.
- Release STOP/SET. Without pressing anything else, wait about 10 seconds for the setting to save and exit.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause time Pause before automatic closing; requires I/L1 ON. | L1 – 5 s L2 – 15 s L3 – 30 s (factory setting) L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – SbS function Sequence of commands for the step-by-step input and its corresponding radio channel. | L1 – Open – stop – close – stop L2 – Open – stop – close – open (factory setting) L3 – Open – close – open – close L4 – Apartment block: ignores the next command while opening L5 – Apartment block 2: a command lasting over 2 s stops the gate L6 – SbS 2: a command shorter than 2 s partially opens the gate; one longer than 2 s opens it fully L7 – Hold-to-run control L8 – Semi-automatic opening, hold-to-run closing |
| L3 – Motor speed V1–V6 are progressively faster speeds; do not exceed the limit for the gate’s weight. | L1 – V1 very slow L2 – V2 slow L3 – V3 medium L4 – V4 fast (factory setting) L5 – V5 very fast L6 – V6 extremely fast L7 – Opens at V4, closes at V2 L8 – Opens at V6, closes at V4 |
| L4 – OGI output function Programmable 24 V / 4 W output. The open-gate indicator is available only with value L1. | L1 – Open-gate indicator L2 – Active when the gate is closed L3 – Active when the gate is open L4 – Radio output 2 L5 – Radio output 3 (factory setting) L6 – Radio output 4 L7 – Maintenance indicator L8 – Electric lock |
| L5 – Motor force Set the force thresholds only as high as necessary and verify them by measuring the forces. | L1 – Extremely light gate L2 – Very light gate L3 – Light gate L4 – Medium-weight gate L5 – Medium-heavy gate (factory setting) L6 – Heavy gate L7 – Very heavy gate L8 – Extremely heavy gate |
| L6 – Partial opening Partial opening distance; limited to the actual learned travel distance. | L1 – 0.5 m L2 – 1 m L3 – 1.5 m L4 – 2 m (factory setting) L5 – 2.5 m L6 – 3 m L7 – 3.4 m L8 – 4 m |
| L7 – Maintenance alert Limit for the number of operating cycles; the automatic value takes force and travel length into account. | L1 – Automatic L2 – 1,000 operating cycles L3 – 2,000 operating cycles (factory setting) L4 – 4,000 operating cycles L5 – 7,000 operating cycles L6 – 10,000 operating cycles L7 – 15,000 operating cycles L8 – 20,000 operating cycles |
| L8 – Error history View the last eight operating cycles; this is not a setting and does not erase the memory. | L1 – Most recent operating cycle L2 – Second most recent L3 – Third most recent L4 – Fourth most recent L5 – Fifth most recent L6 – Sixth most recent L7 – Seventh most recent L8 – Eighth most recent |
Adjusting speed and force does not replace removing friction or an obstruction. When OGI is set as a gate indicator, it is off when the gate is closed, steadily lit when open, flashes slowly while opening, and flashes quickly while closing. For the lock function, the device must match the output voltage and rating.
Long SbS command – hold the gate open
An SbS command lasting longer than 2 s allows the gate to open and remain open, for example when controlled by a timer. Applies unless the SbS input has been reprogrammed for the close function. For normal operation with a relay module, select a short pulse; continuous activation may change the expected behavior.
Remote controls, BusT4 and backup
Install the receiver in the SM connector with the power off. The standalone operator is supplied without a radio receiver; add a receiver to suit the required configuration. The choice of remote control depends on the receiver and its configured coding family, not just the frequency.
| Receiver | Remote control selection |
|---|---|
| OXIBD | Remote controls MYGO2, MYGO4, MYGO8, DOMIW3C, ON3EBD depending on the supported unidirectional or bidirectional mode. For older remotes, check the configured memory family. |
| OXI | Unidirectional O-Code / FloR control, e.g. ON2E, ON4E, ON9E, INTI2, FLO2RE, FLO2R-S. The receiver also supports other coding families; when adding a remote, check the family of the memory already stored. |
| SMXI | Unidirectional receiver with FloR coding, e.g. FLO2RE, FLO2R-S. SMXIS is a different receiver for Smilo; do not confuse these model designations and remotes. |
| OXILR | Long range with compatible LR transmitters, e.g. ON3ELR. LR benefits are available with the corresponding LR remote. |
Radio commands
| Receiver output | Control board command |
|---|---|
| 1 | SbS – step-by-step command |
| 2 | Partial opening |
| 3 | Open |
| 4 | Close |
Pair and delete remotes according to the specific receiver; the motor buttons are not radio-memory buttons. NICE remote pairing instructions and the selected receiver's card list the relevant procedures. After saving, test each button and verify the command it actually triggers.
BusT4 / IBT4N and Aux In
Oview connects via IBT4N to BusT4; it enables configuration, diagnostics, and management of compatible controls. BIDI-WIFI is primarily a programming and diagnostic interface. When choosing a module for everyday control via mobile phone, check the connection method, range, and number of users. BiDi-ZWave is used to connect a compatible drive to a Z-Wave system. Select both modules for the board version actually installed and the relevant Opera interface. BusT4 is not a pair of power terminals. Do not connect the connector to BlueBUS or the antenna.
Aux In is an NC safety input with a STOP function by default; it can be assigned a different function via Oview. After changing the setting, verify the gate's resulting response. Power for the external relay must be handled separately, in accordance with polarity and the 100 mA limit.
Backup battery and Solemyo
For a compatible RBA3R10, you can use the original PS124 or the current PSS124 with the correct cable supplied for the R10. Connect the battery only after completing installation and programming, with the mains disconnected. Use the designated connector and a protected location inside the drive; do not connect the battery to the motor, FLASH, or BlueBUS terminals.
After connecting, test operation both on mains power and on battery power. The number of operating cycles depends on load, temperature, battery age, and charge level. In a Master/Slave pair, each motor needs its own battery.
For a solar system Solemyo use the designated connection and check the energy balance. When powered by Solemyo, the drive must not be connected to the mains at the same time. Useful features include Standby I/L4.
Two sliding gate leaves meeting in the middle – Master/Slave
A pair of compatible RUN1500P drives can operate two sliding gate leaves that move toward each other. Each leaf must independently comply with the weight and operating limits. Two motors do not increase the limit for an individual leaf.
Connect the boards in this order: 1 Master → 1 Slave and 2 Master → 2 Slave as shown by the connectors with matching orientation in the diagram. Here, 1/2 identify positions, not universal power supply +/− terminals. Standard BlueBUS photocells are non-polarized.
- Install both motors and set their opening directions to be opposite, according to the gate-leaf layout.
- With the power off, wire the boards according to the diagram. Shared devices and the radio receiver must be connected to the Master.
- Switch on the power and set the subordinate motor to I/L8 Slave ON.
- Program the devices on the Slave first, then on the Master. Run the travel-learning procedure on the Master.
- Test coordination, all safety responses, and the end positions of both leaves.
The Slave can have its own FLASH, OGI, STOP, and SbS; its SbS opens the Slave leaf only. OPEN, CLOSE, and Aux In are not used on the Slave. Standby, peak load, Slave, OGI, and force can be set independently, and its error history can be read. For backup power, each motor needs its own battery.
Diagnostics and troubleshooting
If a fault occurs, first count the quick FLASH flashes: the sequence repeats after a pause of about one second. Normal flashing during movement is approximately 0.5 s on / 0.5 s off. Disconnect all power supplies before carrying out repairs.
| Flashes | Meaning and next step |
|---|---|
| 1 | BlueBUS Device changed or not recognized; check the wiring, addresses and programming. |
| 2 | Photocell Remove the obstruction, clean and align the optics; check the address and protected direction. |
| 3 | Force limit Check manual movement, friction and stops. Only then, if necessary, adjust the force and remeasure the safety forces. |
| 4 | STOP Check the status of the contacts or safety edge and the STOP wiring. |
| 5 | Internal parameters Wait at least 30 s and repeat the command. If the fault persists, have the control unit serviced. |
| 6 | Operation limit The control board has limited operation; wait for it to cool down and check the permitted cycles. |
| 7 | Internal electrical circuit Disconnect all power sources for a few seconds and repeat the test. If it happens again, have it serviced. |
| 8 | Continuous command Check whether OPEN is active or a timer is running; the control board is waiting for the command to be released. |
| 9 | Automation locked by a command Cancel the electronic lock using the appropriate unlock command. This is not mechanical unlocking with a key. |
Control board LEDs
| LED / status | Meaning |
|---|---|
| BlueBUS off | No power or a fault; check the supply and fuses. |
| BlueBUS continuously on | Serious fault; briefly disconnect all power sources. If it happens again, have it serviced. |
| BlueBUS 1×/s | Normal operation. Two quick flashes indicate an input change or a command received. |
| STOP on / off | On = normal status recognized; off = STOP activated. |
| SbS / OPEN / CLOSE on | The corresponding contact or command is active. |
| L1 + L2 flashing | BlueBUS / STOP device recognition required. |
| L3 + L4 flashing | Leaf length programming required. |
Most common symptoms
| Problem | What to check |
|---|---|
| Remote control LED does not light up | Transmitter battery and correct polarity when replacing it. |
| Remote control lights up, but the gate does not respond | Receiver, transmitter storage and coding family; radio control. |
| No response and BlueBUS is off | Power supply and F1/F2 fuses. First identify the cause of the fault, then replace the fuse only with one of the same type and rating. |
| Movement reverses immediately | Obstruction, resistance in the track or sensitivity; do not increase the force without checking the mechanics. |
| Does not close automatically | I/L1, time II/L1, activated photocell/STOP or continuous OPEN command. |
| OGI does not indicate that the gate is open | Check II/L4 first; the factory setting is radio output 3. |
| Warning light does not work | FLASH wiring, compatibility and short circuit. Do not confuse the light pair with the antenna. |
History of the last eight operations
- Enter programming mode by holding STOP/SET until L1 flashes, then release.
- Use OPEN/CLOSE to select input L8. Hold STOP/SET for about 3 s.
- The illuminated LEDs indicate operations with a fault: L1 is the most recent and L8 the eighth most recent. While holding STOP/SET, use OPEN/CLOSE to select the required operation.
- The selected LED flashes the number of times shown in the diagnostic table. Release STOP/SET.
Emergency movement when a safety device fails
The safest option is to disengage the gate and move it manually. Use the emergency hold-to-run command only when you have a clear view of the unobstructed area and under the conditions specified by the installer: issue the command; if the operator only reports an error, repeat the command within 3 s and hold it. After about 2 s, the gate moves only while the command is held. Safety sensing may be limited; have the device repaired immediately. Do not resolve the issue by permanently bridging the input.
Manual release and maintenance
Disengage only a stationary gate leaf, secured against unintended movement. Insert the supplied key and unlock the release mechanism as indicated on the operator; release the mechanism and move the gate manually. On versions with a release handle, you must also open the handle after unlocking. To re-engage the mechanism, return it to position, lock it and remove the key. Once operation has been restored, check that the mechanism is properly engaged and verify the end positions.
Regular maintenance
Professional maintenance at least every 6 months or after 20,000 operations, whichever comes first. Check the anchors, corrosion, track, pinion, rack, limit switches and all safety devices. Disconnect the mains and backup power supplies before checking the mechanics; repeat the test afterwards. The user may clean the photocell optics with a soft, damp cloth and remove obstructions when the operator is secured.
Maintenance reminder
| Percentage of the set limit | FLASH / OGI as a maintenance indicator |
|---|---|
| Below 80% | FLASH operates normally; OGI lights up for 2 s at the start of opening. |
| 81–100% | FLASH lights up for 2 s at the start of movement; OGI flashes during movement. |
| Above 100% | FLASH lights up for 2 s at the start and end of movement; OGI flashes continuously. |
The OGI function must be set to II/L4, value L7. The service limit is set II/L7. The count is based on manoeuvres, not years of operation.
Reading the counter
- Enter programming mode and select input LED L7.
- Hold STOP/SET for about 3 seconds until the value LED lights up; keep holding the button.
- Briefly press OPEN and CLOSE together. The number of flashes of the value LED indicates increments of 10% of the limit; for example, 4 flashes mean 40–49%. Below 10%, the LED does not flash.
- Release STOP/SET.
Resetting the service counter
- Only after completing maintenance, enter programming mode and select input L7.
- Hold STOP/SET for about 3 seconds until the value LED lights up, and keep holding it.
- Press and hold OPEN and CLOSE simultaneously for at least 5 seconds, then release them. Rapid flashes confirm that the counter has been reset.
- Release STOP/SET and check the service limit setting.
Resetting the counter does not erase the transmitters or control unit settings. When changing accessories, use device learning; when resetting the travel limits, use travel-length learning. When replacing the control unit, commissioning and tests must be carried out for the specific controller; the radio memory procedure applies to the receiver.
Technical specifications and dimensions
| Parameter | Value |
|---|---|
| Model | NICE RUN1500P |
| Limit switch | Inductive |
| Motor / mains supply | 24 V DC / 230 V AC, 50–60 Hz |
| Control unit | Built-in; RBA3R10 |
| Gate leaf weight / length | Maximum 1,500 kg / 14 m, subject to the conditions specified when selecting the drive |
| Maximum power input / current draw | 400 W / 2 A |
| Maximum starting torque / force | 35 Nm / 1,000 N |
| Rated torque / force | 20 Nm / 560 N |
| No-load speed | 0.25 m/s; six basic speed settings of approximately 100 / 85 / 70 / 55 / 45 / 30% |
| Speed at rated load | 0.18 m/s |
| Operation | Maximum 60 cycles/hour with a short, lightweight gate leaf; reduce according to length and weight |
| Continuous operation | Maximum 10 minutes |
| Pinion | Module 4, Z18, 12.6 mm pitch, 72 mm pitch diameter |
| Ingress protection / temperature | IP44 / −20 to +50 °C |
| Drive weight | 19 kg |
| Installation clearance | As shown in the dimension drawing below and according to the actual cover version supplied |
| Auxiliary accessory power supply | 24 V DC, 100 mA total; + left SbS, − right STOP, according to the diagram orientation |
| OGI | 24 V, maximum 4 W; programmable function |
| Radio receiver | Optional, for the SM connector |
| Backup power | Compatible PS124 / PSS124 with the appropriate cable; alternatively, Solemyo when mains power is disconnected |
The cover protects the drive in normal outdoor conditions; IP44 does not mean it can be submerged. During installation, leave enough space to open the cover, carry out maintenance and release the drive manually. Dispose of electrical and electronic components and batteries at the appropriate collection point, not with regular household waste.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]