NICE Run RUN1500 – standalone drive for sliding gates (A)


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE Run RUN1500 – standalone drive for sliding gates (A) NICE Run RUN1500 – standalone drive for sliding gates (A)
NICE-RUN1500-A
in stock
€604.14 excluding VAT
€743.09 including VAT

 pcs
Weight
19 kg

Description of NICE Run RUN1500 – standalone drive for sliding gates (A)

NICE RUN1500 is a standalone non-reversible operator for sliding gates with a gate leaf weighing up to 1,500 kg and measuring 14 m in length. The motor is 24 V DC, mains power supply 230 V AC. It has a built-in RBA3R10 control unit and electromechanical limit switch.

The standalone motor differs from the kit: choose the radio receiver, remote control, photocells, warning light and rack according to the equipment required.

Quick navigation
AccessoriesKits and equipment
Selection and duty cyclesInstallation
WiringPhotocells
Initial startupProgramming
Operation and backupMaster/Slave
DiagnosticsManual release
MaintenanceSpecifications
PDF manual

Accessories and control unit

The standalone operator includes the control unit. For a complete automation system, add a rack, controls and safety devices suitable for the specific gate. RUN1500 kits have the equipment listed separately.

WhatWhyType
Control unitFor operator setup and servicing; when replacing it, check the label on the installed board.
Warning lightIndicates movement. The FLASH output is low-voltage.
PhotocellsDetect an obstacle in the protected area. They do not replace an assessment of all gate-related risks.
TransmitterChoose remote controls to match the receiver and radio coding family.
ReceiverWithout a receiver, the motor cannot receive radio commands on its own. NICE receivers.
Mobile controlDistinguish between drive setup and everyday operation. Wi-Fi relay modules connect using a volt-free contact.
AntennaImproves reception when suitably positioned. The antenna does not power the warning light.
KeypadAccess without a separate remote control.
Key switchKey-operated control via a volt-free contact.
Card readersEntry using a card or key fob.
RackTransfers the pinion's movement to the gate leaf. Choose the type based on the load and mounting method.
Backup power supplyAllows limited operation during a power outage.

Current replacement board: RBA3R10. Older RBA3 has been replaced. For an existing installation, check the actual control board and connectors; the RUN family designation alone does not mean that all models use the same control unit.

Drive and kits included

  • 1 × NICE RUN1500 motor with a 24 V motor and built-in control unit; the radio receiver for a standalone drive is sold separately.
  • 2 × release keys for manual operation.
  • Mounting and anchoring hardware and end components compatible with the RUN1500 version with an electromechanical limit switch.
  • Installation manual. The rack, receiver, remote control and safety equipment are selected separately.

The kits include a RUN1500 motor with a mechanical limit switch, an OXIBD receiver and one MYGO4 remote control. They differ in photocells, warning light and rack; the key switch is sold separately.

KitAdditional equipment compared with the standalone motor
RUN1500 (B)OXIBD + 1 × MYGO4
without photocells, warning light or rack
RUN1500 (C)OXIBD + 1 × MYGO4
EPMB
RUN1500 (D)OXIBD + 1 × MYGO4
EPMB, ELDC
RUN1500 (E)OXIBD + 1 × MYGO4
EPMB, 4 m LZ-1
RUN1500 (F)OXIBD + 1 × MYGO4
EPMB, ELDC, 4 m LZ-1

Kit with accessoriesKit including rack
RUN1500 (D) kit
NICE RUN1500 (D) – actual kit contents
OXIBD, MYGO4, EPMB, ELDC.
RUN1500 (F) kit
NICE RUN1500 (F) – actual kit contents
OXIBD, MYGO4, EPMB, ELDC, 4 m LZ-1.

When comparing options, check the complete gate travel, duty cycle and power supply. A higher weight limit alone does not guarantee suitability for a particular installation.

Drive features

  • Durable body made of aluminium alloy with an epoxy finish and an impact-resistant cover.
  • BlueBUS with two-wire wiring and support for addressed photocells.
  • Adjustment of speed, force and pause; automatic closing can be enabled.
  • The control unit accounts for temperature and limits the number of operations under overload. The force margin must still be checked mechanically.
  • Diagnostics via warning light and LEDs, memory for the last eight operations and a service counter.
  • Master/Slave for two sliding gate leaves moving in opposite directions.

Drive selection and operating limits

The RUN1500 is designed for one sliding gate leaf weighing up to 1,500 kg and measuring up to 14 m. Weight, length and resistance to movement must be considered together. The maximum weight rating does not mean that every 1,500 kg gate should be operated at the highest speed.

What to checkLimit / condition
Gate leaf weightMaximum 1,500 kg; the number of cycles and permitted speed decrease as the weight increases.
Gate leaf lengthMaximum 14 m; length determines the baseline number of cycles.
Start-upThe force required must be less than half of 1,000 N, i.e. less than 500 N.
Smooth movementThe force required must be less than half of 560 N, i.e. less than 280 N throughout the entire travel.
Safety marginNICE recommends a 50% force margin to allow for increased friction in adverse weather.

For general selection, we recommend allowing a margin for both dimensions and weight, aiming for around 80% of the maximum values. This is a selection guide, not a substitute for measuring the required force or checking wind, ice buildup and the cycle table. The gate leaf must slide smoothly by hand and must not start moving on its own.

Number of cycles by gate length

Gate leaf lengthCycles/hourConsecutive
Up to 4 m6030
Over 4 m up to 6 m4020
Over 6 m up to 7 m3417
Over 7 m up to 8 m3015
Over 8 m up to 10 m2012
Over 10 up to 12 m2010
Over 12 up to 14 m178

Reduction by weight

Gate leaf weightCycle ratioMaximum speed
Up to 200 kg100 %V6
Over 200 up to 400 kg100 %V6
Over 400 up to 500 kg95 %V6
Over 500 up to 600 kg90 %V5
Over 600 up to 700 kg85 %V5
Over 700 up to 800 kg80 %V5
Over 800 up to 900 kg75 %V5
Over 900 up to 1 000 kg70 %V4
Over 1 000 up to 1 200 kg65 %V4
Over 1 200 up to 1 350 kg60 %V3
Over 1 350 up to 1 500 kg55 %V3

Multiply the values in the first table by the ratio in the second table, and do not exceed the resulting value. One cycle means one opening and one closing. Example: 5 m / 650 kg gate leaf: 40 × 0.85 = 34 cycles/h, 20 × 0.85 = 17 consecutively, maximum V5. Continuous operation is limited to 10 minutes. At high temperatures, the protection system may further limit the number of operations. Speed setting.

Estimated service life

Add the indices for length, weight, and relevant conditions. Find the total on the horizontal axis of the chart and read off the approximate number of cycles. The result is an estimate assuming regular maintenance; it is not a service-life guarantee or a number of years.

Characteristics of the complete automation systemIndexService life chart
Length under 6 m5 %

Estimated service life chart for the RUN1500 operator – load index and number of cycles

Horizontal axis: index in %.
Vertical axis: number of cycles.

6 to 9 m10 %
9 to 12 m15 %
12 to 14 m20 %
Weight 100 to 200 kg5 %
200 to 400 kg10 %
400 to 600 kg20 %
600 to 800 kg30 %
800 to 1 000 kg40 %
1 000 to 1 200 kg50 %
1 200 to 1 500 kg60 %
Over 40 °C / below 0 °C or humidity above 80 %20 %
Dust, sand, or salinity15 %
Speed higher than L4 “fast”15 %

Example: 6.5 m / 450 kg in a dusty environment: 10 % + 20 % + 15 % = 45 %, approximately 200,000 cycles on the chart. For values at the boundary between intervals, use the higher index for a conservative assessment. Do not extrapolate the chart beyond its plotted range. The operator must not be installed in an acidic, saline, or explosive atmosphere; the salinity row in the table does not permit this type of use.

Installing the operator and rack

Before carrying out any work, disconnect the mains supply and any battery or solar power supply. The gate must have solid mechanical end stops, anti-derailment protection, and sufficiently robust guides. The operator limit switch does not replace the gate's mechanical stop.

  1. Check that the gate moves smoothly by hand along its entire travel and the required-force limits. Protect against pinch points, including at the rear of the sliding gate leaf.
  2. Choose a solid, level foundation away from areas at risk of flooding. Keep the key and cover accessible. Prepare the cable conduits so they do not direct water into the operator.
  3. Position the anchor plate parallel to the gate, according to the original drawing. The anchor thread should extend approximately 30–40 mm above the plate. Allow the concrete to cure completely before tightening.
  4. Install the operator and align it with the gate leaf. After installing the rack, tighten the fasteners and cover the nuts with the supplied caps.

Positioning the RUN1500 foundation plate relative to the gate

Anchoring the RUN1500 foundation plate and thread height of 30–40 mm

Rack – module 4

The pinion has module 4, 18 teeth. The rack must have the same module and a load capacity suitable for the gate leaf. The weight of the gate must not rest on the pinion. Choose nylon or steel versions based on the specifications of the specific rack, not just by matching the module.

  1. Release the motor and position the gate leaf at least 50 cm from the closed end position when installing the rack.
  2. Fasten the rack to the gate leaf using suitable brackets; maintain a gap between the rack and pinion along the entire travel of 1–2 mm.
  3. When joining sections, maintain consistent tooth spacing. Manually move the gate through its full travel and check the alignment; lateral offset must not exceed 5 mm, according to the manufacturer.
  4. After tightening, check again that movement is free, the clearance is correct, and the limit switches work.

1–2 mm clearance between the rack and pinion of the RUN1500 drive

Rack alignment with the RUN1500 pinion along the entire travel

End positions – variant differences

The RUN1500 has an electromechanical limit switch. The end stops on the rack operate the switch in the open and closed positions. Position them so that the gate leaf stops before the fixed stops during powered operation and the switch reliably changes state when moved manually.

Before programming, set the opening direction using the switch on the board, according to the orientation of the drive. Disconnect all power supplies before changing the direction. After programming the travel check that the gate slows down about 50–70 cm before the end and stops about 2–3 cm before the mechanical stop. The actual position must be confirmed by testing both directions.

RUN1500 opening direction switch – gate leaf moves to the left

RUN1500 opening direction switch – gate leaf moves to the right

Wiring

PurposeCable and maximum length
Mains power supply3 × 1.5 mm² up to 30 m. For longer runs, use 3 × 2.5 mm² and protective earthing for the automation system as required by the specific installation.
Warning light2 × 0.5 mm²; 20 m.
AntennaRG58; maximum 20 m, recommended length under 5 m.
BlueBUS / photocells2 × 0.5 mm² up to 30 m; for runs over 30 m and up to 50 m, use 2 × 1 mm².
Fixed safety edges2 × 0.5 mm²; 30 m, connect according to the STOP type.
Moving safety edge2 × 0.5 mm²; 30 m; use a suitable device to connect to the moving gate leaf, e.g. FT210B.
Key switchTwo 2 × 0.5 mm² cables or one 4 × 0.5 mm² cable; 50 m.

Use cables suitable for the environment. Leave approximately 20–30 cm of spare cable in the drive and secure the cables so they cannot be pulled out of the terminals. The mains supply cable must have a protective conductor and provision for complete, safe disconnection.

Wiring and board orientation

The drive power supply is 230 V AC; the motor itself is 24 V DC. Do not connect mains voltage to the low-voltage terminals or BlueBUS. The board has OPEN, STOP/SET and CLOSE buttons, L1–L8 LEDs, an SM receiver connector and a BusT4 interface via IBT4N.

Mains supply cable and cable clamp for the RUN1500 drive

RUN1500 board and removable terminal block orientation

Wiring diagram

RUN1500 wiring diagram – FLASH, OGI, BlueBUS, STOP, SbS, OPEN, CLOSE, Aux In, antenna and IBT4N

FLASH = warning light; OGI = programmable output; TX/RX = photocell transmitter and receiver; Aerial = antenna; Receiver = remote control receiver; Selector = direction switch. The terminal labels are the same as those on the board.

TerminalWiring and important condition
FLASHOutput for one or two warning lights with 12 V bulbs, up to 21 W, according to the manufacturer's wiring instructions. For LED equipment, use a compatible ELDC. Warning light and antenna.
OGI24 V DC (−30% / +50%), maximum 4 W; the function is set by II/L4. The factory setting is radio output 3, not an open-gate indicator by default. The +/− order for this output is not shown in the diagram; do not infer it from the auxiliary power supply.
BlueBUSTwo-wire power and communication for compatible accessories. Photocells are connected in parallel with no polarity.
STOPSafety input: NO, NC or 8.2 kΩ; the type is detected during programming. A change of state stops movement and briefly reverses it.
SbSStep-by-step command via a voltage-free NO contact; behaviour is determined by II/L2.
OPENOpen via a voltage-free NO contact.
CLOSEClose via a voltage-free NO contact. If I/L7 ON, this is a partial opening.
Aux InAuxiliary input, factory-set as NC with a STOP function. Reprogramming via Oview. This is not an accessory power output.
ANTENNA / AerialConnect the coaxial cable's core and shield according to the original diagram; this is not a +/− power supply.

Auxiliary power supply – exact polarity

With the connector oriented as shown in the following image: right terminal of the STOP pair = negative (−), left terminal of the SbS pair = positive (+). The auxiliary output is 24 V DC, −30% / +50%, maximum 100 mA in total. On the accessory, connect + to the power supply + and − to the power supply −; its control NO/COM contact remains separate.

RUN1500 auxiliary power – right STOP terminal negative, left SbS terminal positive, 24 V DC

The polarity order applies to this auxiliary power connection. Do not apply it to FLASH, OGI, the antenna or BlueBUS. A higher-current module must have a suitable separate power supply; connect its voltage-free contact to SbS. Aux In is not used for power.

ELDC warning light and antenna

ELDC has a low-voltage light input of 12–36 V DC; connect it to FLASH. The detail below distinguishes the light pair from the antenna pair. Do not connect 230 V to the light pair. In the wiring shown, the manufacturer does not indicate the +/− order of the light pair; do not use the polarity of the STOP/SbS auxiliary output for it.

ELDC beacon terminals – low-voltage light and separate antenna

Antenna

Connect the ELDC antenna or ABFKIT using a separate RG58 cable to the antenna input: connect the center conductor to the signal symbol and the braid to the shield symbol, as shown in the diagram. Do not connect the antenna wires to the power supply pair. The antenna must match the receiver frequency.

Key switch, relay and control inputs

For SbS, OPEN and CLOSE, use voltage-free NO contacts. For EKS or a relay module, connect COM and NO from the selected contact to the pair of terminals for the relevant input. Contacts have no +/− polarity. Do not supply power to the module inputs. With a permanent OPEN contact, the gate may remain open as it would with a timer; do not switch off the drive’s mains supply for this purpose.

STOP and safety edge

Device typeWiring method
NO contactsIn parallel.
NC contactsIn series.
Two 8.2 kΩ edgesMay be wired in parallel, depending on the manufacturer; for more than two, cascade them with a single 8.2 kΩ termination.
NO / NC combinationParallel branches, with an 8.2 kΩ resistor in series in the NC branch, as specified in the approved wiring diagram.

Voltage-free contacts and passive resistive edges have no power supply +/−. An electronic edge may require its own power supply – check its manual. After every wiring change, perform device learning and a safety test. NO/NC wiring alone does not provide the same fault diagnostics as a resistive edge. Do not jumper the safety input to clear a fault.

BlueBUS photocells

For example, EPMB: connect both TX and RX devices in parallel to the same two BlueBUS wires. There is no plus or minus polarity. TX and RX in a pair must have the same jumpers and address; assign the next pair a different supported address. After adding or removing a device, repeat the learning procedure.

Protective photocell layout for the RUN1500 sliding gate

Pair addressProtected movement / position
FOTOOuter pair at approximately 50 cm; stops and reverses movement during closing.
FOTO IIOuter pair at approximately 100 cm; closing protection.
FOTO 1Inner pair at approximately 50 cm; closing protection.
FOTO 1 IIInner pair at approximately 100 cm; closing protection.
FOTO 2Outer pair for protection during opening.
FOTO 2 IIInner pair for protection during opening.
FOTO 3Pair covering the entire travel area; use together with FOTO II requires correct positioning of TX/RX relative to each other.

The precise jumper settings are shown on the EPMB – jumper settings table. After configuration, check the optical alignment and the response of each pair in its protected direction. For a standard safety configuration, do not change a pair to an opening command by cutting link A.

EPMOW requires IBW and is not a substitute for a wired pair without additional equipment. FT210B with a battery-powered transmitter on the moving gate leaf sends the resistive edge status to BlueBUS; wire and address it according to the FT210B manual.

Initial startup and learning

  1. Check the installation, limit switches, grounding and wiring. The gate leaf must be approximately halfway along its travel, and the motor must be locked.
  2. Connect the power supply. BlueBUS should flash approximately once per second, and the TX/RX photocells should indicate operation; FLASH and OGI should be off. If there is a fault, disconnect the power supply and check the wiring.
  3. Perform device learning, then travel learning, and finally the tests. The entire area must be clear while the gate is moving.

Device learning – OPEN + STOP/SET

  1. Press and hold OPEN and STOP/SET simultaneously for about 3 seconds.
  2. When L1 and L2 start flashing rapidly, release the buttons.
  3. Wait for the process to finish. The STOP LED must be lit, and L1/L2 must stop indicating that learning is in progress. L1–L8 then indicate the function statuses.

Perform this step even if no safety accessories are connected. If L1/L2 are flashing, recognition is not complete; do not proceed to travel learning blindly.

OPEN and STOP/SET for BlueBUS and STOP learning

Travel learning – CLOSE + STOP/SET

  1. After successful device recognition, press and hold CLOSE and STOP/SET for about 3 seconds.
  2. When the motor starts, release the buttons. The first movement should be opening. If it closes, press STOP/SET, disconnect the power supply, correct the direction switch setting, and repeat the procedure.
  3. The drive opens the gate to the limit switch and then closes it. Wait for the entire learning process to finish and watch for any diagnostic indications.
  4. Perform several complete opening and closing cycles. Check the slow-down, end positions, and that the motor does not press against a fixed stop.

CLOSE and STOP/SET for learning the gate leaf travel

Testing and handover

  1. Check that the installation is secure and test the manual release. During testing, the gate leaf must be movable by hand in both directions using a force of no more than 390 N; it must also meet the stricter force requirements for selecting the drive.
  2. Test each photocell pair and the safety edge individually. When the state changes, BlueBUS signals with two rapid flashes; also check that the gate leaf responds correctly.
  3. Have the forces professionally measured after adjusting sensitivity and after any change that could affect safety. Meeting the weight limit and having photocells alone are not sufficient.
  4. Provide the manual, documentation for the complete automation system, instructions for releasing the drive, and a maintenance plan. Do not hand over the gate with the safety test incomplete.

Control unit programming

OPEN / CLOSE scroll through the LED selection; STOP/SET confirms or, when held, opens programming. During normal operation, they open, stop, and close the gate. Change settings with the gate stationary. Repeat the test after changing the force, speed, or behavior of the safety devices.

OPEN, STOP/SET, CLOSE buttons and LEDs L1 to L8

Level I – Switching functions on and off

  1. Hold STOP/SET until L1 starts flashing, approximately 3 seconds; then release.
  2. Use OPEN or CLOSE to select the function LED.
  3. Briefly press STOP/SET. A short flash indicates OFF; a longer flash indicates ON.
  4. If desired, change another function. If no button is pressed for approximately 10 seconds, programming ends and the changes are saved.

LED – function and meaningStatus
L1 – Automatic closing
ON: closes after opening, following the pause set in II/L1. OFF: automatic closing disabled.
Factory default: OFF
ON = enabled
OFF = disabled
L2 – Closing after photocell release
ON: closes 5 s after the photocell is cleared. If automatic closing is disabled, the gate first completes opening; if enabled, clearing the photocell may shorten the opening cycle. STOP cancels this sequence.
Factory default: OFF
ON = enabled
OFF = disabled
L3 – Always close
ON: after power is restored, detects an open gate and starts closing after a 5 s pre-flash warning. OFF: does not perform this recovery action.
Factory default: OFF
ON = enabled
OFF = disabled
L4 – Standby
ON: about one minute after movement ends, switches off BlueBUS and the indicators, except for the slow BlueBUS flashing; operation resumes when a command is received. Useful with battery or solar power.
Factory default: OFF
ON = enabled
OFF = disabled
L5 – Starting boost
ON: applies maximum force at startup instead of smooth acceleration. After startup, II/L5 applies. OFF: smooth start.
Factory default: OFF
ON = enabled
OFF = disabled
L6 – Pre-flashing
ON: the warning light flashes for 3 s before movement starts. OFF: it starts flashing when movement begins.
Factory default: OFF
ON = enabled
OFF = disabled
L7 – CLOSE as partial opening
ON: the CLOSE input controls partial opening as set in II/L6. OFF: the CLOSE input closes the gate.
Factory default: OFF
ON = enabled
OFF = disabled
L8 – Slave mode
ON: the slave motor in a pair; commands and movement are controlled by the Master. OFF: standalone / master control.
Factory default: OFF
ON = enabled
OFF = disabled

Level II – Parameter values

  1. Hold STOP/SET until L1 flashes, then release. Use OPEN/CLOSE to select the parameter’s input LED.
  2. Press and hold STOP/SET again. After about 3 seconds, the value LED lights up.
  3. Keep holding STOP/SET and use OPEN/CLOSE to select the value.
  4. Release STOP/SET. Without pressing anything else, wait about 10 seconds for the setting to be saved and programming to end.

Input LED – name and descriptionSetting LED – value
L1 – Pause time
Pause before automatic closing; requires I/L1 ON.
L1 – 5 s
L2 – 15 s
L3 – 30 s (factory default)
L4 – 45 s
L5 – 60 s
L6 – 80 s
L7 – 120 s
L8 – 180 s
L2 – Step-by-step function
Command sequence for the step-by-step input and its corresponding radio channel.
L1 – Open – stop – close – stop
L2 – Open – stop – close – open (factory default)
L3 – Open – close – open – close
L4 – Condominium: ignores the next command while opening
L5 – Condominium 2: a command held for more than 2 s stops the gate
L6 – Step-by-step 2: a command held for less than 2 s partially opens the gate; held for more than 2 s, it fully opens it
L7 – Hold-to-run control
L8 – Semi-automatic opening, closing while held
L3 – Motor speed
V1–V6 are progressively faster speeds; do not exceed the limit for the gate’s weight.
L1 – V1 very slow
L2 – V2 slow
L3 – V3 medium
L4 – V4 fast (factory default)
L5 – V5 very fast
L6 – V6 extremely fast
L7 – Opens at V4, closes at V2
L8 – Opens at V6, closes at V4
L4 – OGI output function
Programmable 24 V / 4 W output. The open-gate indicator is available only at value L1.
L1 – Open-gate indicator
L2 – Active when the gate is closed
L3 – Active when the gate is open
L4 – Radio output 2
L5 – Radio output 3 (factory default)
L6 – Radio output 4
L7 – Maintenance indicator
L8 – Electric lock
L5 – Motor force
Set force thresholds only as high as necessary and verify them by measuring the forces.
L1 – Extremely light gate
L2 – Very light gate
L3 – Light gate
L4 – Medium-weight gate
L5 – Medium-heavy gate (factory default)
L6 – Heavy gate
L7 – Very heavy gate
L8 – Extremely heavy gate
L6 – Partial opening
Partial opening distance; limited to the actual learned travel distance.
L1 – 0.5 m
L2 – 1 m
L3 – 1.5 m
L4 – 2 m (factory setting)
L5 – 2.5 m
L6 – 3 m
L7 – 3.4 m
L8 – 4 m
L7 – Maintenance reminder
Number of operating cycles threshold; the automatic value takes account of the force and travel length.
L1 – Automatic
L2 – 1,000 operating cycles
L3 – 2,000 operating cycles (factory setting)
L4 – 4,000 operating cycles
L5 – 7,000 operating cycles
L6 – 10,000 operating cycles
L7 – 15,000 operating cycles
L8 – 20,000 operating cycles
L8 – Error history
View the last eight operating cycles; this does not change settings or erase the memory.
L1 – Last operating cycle
L2 – Second from last
L3 – Third from last
L4 – Fourth from last
L5 – Fifth from last
L6 – Sixth from last
L7 – Seventh from last
L8 – Eighth from last

Adjusting speed and force does not eliminate friction or remove an obstruction. When OGI is used as a gate status indicator, it is off when the gate is closed, lit when open, flashes slowly while opening and quickly while closing. For the lock function, the device must match the output voltage and rating.

Long SbS command – hold open

An SbS command lasting longer than 2 s opens the gate and keeps it open, for example when triggered by a timer. This applies unless the SbS input has been reprogrammed for the closing function. For normal operation with a relay module, select a short pulse; continuous activation may cause unexpected behavior.

Remote controls, BusT4 and backup

With the power off, install the receiver in the SM connector. The standalone operator does not include a radio receiver; the RUN1500 kits listed include OXIBD. Choose a remote control based on the receiver and its configured coding family, not just the frequency.

Installing a plug-in receiver in the RUN1500 SM connector

ReceiverRemote control selection
OXIBDRemote controls MYGO2, MYGO4, MYGO8, DOMIW3C, ON3EBD depending on the supported unidirectional or bidirectional mode. For older remote controls, check the configured memory family.
OXIUnidirectional O-Code / FloR control, e.g. ON2E, ON4E, ON9E, INTI2, FLO2RE, FLO2R-S. The receiver also supports other coding families; when adding a remote control, check the family of the memory already stored.
SMXIUnidirectional receiver with FloR coding, e.g. FLO2RE, FLO2R-S. SMXIS is a different receiver for Smilo; do not confuse these model designations and remote controls.
OXILRLong range with compatible LR transmitters, e.g. ON3ELR. LR benefits apply when used with the corresponding LR remote control.

Radio commands

Receiver outputControl board command
1SbS – step-by-step command
2Partial opening
3Open
4Close

Pair and delete remote controls according to the specific receiver; the motor buttons are not radio memory buttons. NICE remote control pairing guide and the selected receiver's card provide the relevant procedures. After saving, test every button and confirm the command it actually sends.

BusT4 / IBT4N and Aux In

Oview connects via IBT4N to BusT4, enabling setup, diagnostics and management of compatible control systems. BIDI-WIFI is primarily a programming and diagnostic interface. When choosing a module for everyday control from a mobile device, check the connection method, range and number of users. BiDi-ZWave is used to connect a compatible operator to a Z-Wave system. Choose both modules for the actual control board version installed and the relevant Opera interface. BusT4 is not a pair of power supply terminals. Do not connect this connector to BlueBUS or the antenna.

Connecting Oview to a RUN1500 operator via IBT4N

Aux In is a factory-set NC safety input with a STOP function; it can be assigned a different function via Oview. After changing it, verify the gate’s response. The external relay’s power supply must be handled separately according to the polarity and 100 mA limit.

Backup battery and Solemyo

For a compatible RBA3R10, you can use the original PS124 or the current PSS124 with the correct cable supplied for the R10. Connect the battery only after installation and programming are complete, with the mains disconnected. Use the designated connector and a protected location inside the operator; do not connect the battery to the motor, FLASH or BlueBUS terminals.

Location of the PS124 backup battery and connector in the RUN1500

After connecting it, test operation on both mains and battery power. The number of operating cycles depends on the load, temperature, battery age and charge level. In a Master/Slave pair, each motor needs its own battery.

For a solar system, Solemyo use the designated connection and check the energy balance. When powered by Solemyo, the operator must not be connected to the mains at the same time. It is useful to enable Standby I/L4.

Connecting the Solemyo solar system to the RUN1500

Two sliding leaves moving in opposite directions – Master/Slave

A pair of compatible RUN1500 operators can control two sliding leaves moving in opposite directions. Each leaf must independently comply with the weight and operating limits. Two motors do not increase the limit for an individual leaf.

RUN1500 Master and Slave wiring – BlueBUS, warning lights, photocells and controls

Connect the boards in this order: 1 Master → 1 Slave and 2 Master → 2 Slave, following the connector orientation shown in the diagram. Here, numbers 1 and 2 indicate positions, not universal power supply +/−. Standard BlueBUS photocells are non-polarized.

  1. Install both operators and set their opening directions to oppose each other, according to the leaf layout.
  2. With the power off, connect the boards as shown in the diagram. Shared devices and the radio receiver must be connected to the Master.
  3. Switch on the power and set the subordinate operator to I/L8 Slave ON.
  4. Learn the devices on the Slave first, then on the Master. Perform travel learning on the Master.
  5. Test coordinated operation, all safety responses and the end positions of both leaves.

The Slave can have its own FLASH, OGI, STOP and SbS; its SbS control opens only the Slave leaf. OPEN, CLOSE and Aux In are not used on the Slave. Standby, peak force, Slave, OGI and force can be set independently, and the error history can be read. For backup power, each operator needs its own battery.

Diagnostics and troubleshooting

If a fault occurs, first count the quick FLASH flashes: the sequence repeats after a pause of about one second. Normal flashing during operation is about 0.5 s on / 0.5 s off. Disconnect all power supplies before carrying out repairs.

FlashesMeaning and next step
1BlueBUS
Device changed or not recognized; check the wiring, addresses and learning.
2Photocell
Remove any obstruction, clean and align the optics; check the address and protected direction.
3Force limitation
Check manual movement, friction and stops. Only then, if necessary, adjust the force and measure the safety forces again.
4STOP
Check the status of the contacts or safety edge and the STOP wiring.
5Internal parameters
Wait at least 30 s and repeat the command. If the error persists, have the control unit serviced.
6Operation limit
The board has limited operation; allow it to cool and check the permitted cycles.
7Internal electrical circuit
Disconnect all power sources for a few seconds, then repeat the test. If it happens again, have it serviced.
8Continuous command
Check whether OPEN is engaged or a timer is active; the board is waiting for the command to be released.
9Automation locked by a command
Cancel the electronic lock using the appropriate unlock command. This is not the mechanical key release.

LEDs on the board

LED / statusMeaning
BlueBUS offNo power or a fault; check the supply and fuses.
BlueBUS continuously onSerious fault; briefly disconnect all power sources. If the fault recurs, have it serviced.
BlueBUS 1×/sNormal operation. Two quick flashes indicate an input change or a received command.
STOP on / offOn = normal state recognized; off = STOP activated.
SbS / OPEN / CLOSE onThe corresponding contact or command is active.
L1 + L2 flashingBlueBUS / STOP device recognition required.
L3 + L4 flashingLeaf length learning required.

Common symptoms

ProblemWhat to check
Remote control LED does not lightTransmitter battery and correct polarity when replacing it.
Remote control lights up, but the gate does not respondReceiver, transmitter memorization and coding family; Radio control.
Unresponsive and BlueBUS is not litPower supply and fuses F1/F2. First identify the cause of the fault, then replace the fuse only with one of the same type and rating.
Reverses direction immediatelyObstruction, resistance in the gate travel, or sensitivity; do not increase the force without checking the mechanics.
Does not close automaticallyI/L1, time II/L1, activated photocell/STOP, or a permanently active OPEN input.
OGI does not indicate that the gate is openFirst check II/L4; the factory setting assigns radio output 3.
Warning light does not workFLASH wiring, compatibility, and short circuit. Do not confuse the light pair with the antenna.

History of the last eight manoeuvres

  1. Enter programming mode by holding STOP/SET until L1 flashes, then release.
  2. Use OPEN/CLOSE to select input L8. Hold STOP/SET for about 3 seconds.
  3. Lit LEDs indicate manoeuvres with an error: L1 is the most recent, through to L8, the eighth from the end. While holding STOP/SET, use OPEN/CLOSE to select the desired manoeuvre.
  4. The selected LED flashes the number of times specified in the diagnostic table. Release STOP/SET.

Emergency operation if a safety device fails

The safest option is to release the gate and move it manually. Use the emergency hold-to-run command only when you have a clear view of the unobstructed area and under the conditions specified by the installer: issue the command; if the operator only reports an error, repeat the command within 3 seconds and hold it. After about 2 seconds, it will move only while the command is held. Safety detection may be limited; have the device repaired immediately, and do not leave the input permanently bypassed.

Manual release and maintenance

Release only when the gate leaf is stationary, and secured against moving on its own. Insert the supplied key and unlock the release mechanism as indicated on the operator; release the mechanism and move the gate manually. On versions with a release handle, the handle must also be opened after unlocking. To re-engage the mechanism, return it to its original position, lock it, and remove the key. When operation resumes, check that the mechanism is properly engaged and verify the limit positions.

Manual release key for the RUN1500 operator

Routine maintenance

Have the operator professionally serviced at least every 6 months or after 20,000 manoeuvres, whichever comes first. Check the anchoring, corrosion, guide, pinion, rack, limit switches, and all safety devices. Disconnect the mains supply and backup power sources before checking the mechanics; carry out a test afterwards. Users may clean the photocell lenses with a soft, damp cloth and remove obstructions while the operator is secured.

Maintenance warning

Percentage of the set limitFLASH / OGI as a maintenance indicator
Below 80%FLASH operates normally; OGI lights up for 2 seconds at the start of opening.
81–100%FLASH lights up for 2 seconds at the start of movement; OGI flashes while the gate is moving.
Above 100%FLASH lights up for 2 seconds at the start and end of movement; OGI flashes continuously.

The OGI function must be set to II/L4, value L7. Set the service limit using II/L7. The counter tracks manoeuvres, not years of operation.

Reading the counter

  1. Enter programming mode and select input LED L7.
  2. Hold STOP/SET for about 3 seconds until the value LED lights up; continue holding the button.
  3. Briefly press OPEN and CLOSE together. The number of flashes of the value LED indicates increments of 10% of the limit; for example, 4 flashes mean 40–49%. Below 10%, the LED does not flash.
  4. Release STOP/SET.

Resetting the service counter

  1. Only after maintenance has been carried out, enter programming mode and select input L7.
  2. Hold STOP/SET for about 3 seconds until the value LED lights up, then continue holding it.
  3. Press and hold OPEN and CLOSE together for at least 5 seconds, then release them. Rapid flashes confirm that the counter has been reset.
  4. Release STOP/SET and check the service limit setting.

Resetting the counter does not erase transmitters or control board settings. When changing accessories, use device learning; when resetting the travel limits, use travel-length learning. When replacing the control board, commission and test it according to the specific control unit; the radio memory procedure applies to the receiver.

Technical specifications and dimensions

ParameterValue
ModelNICE RUN1500
Limit switchElectromechanical
Motor / mains supply24 V DC / 230 V AC, 50–60 Hz
Control unitBuilt-in; RBA3R10
Gate weight / leaf lengthUp to 1,500 kg / 14 m, subject to the conditions stated in the operator selection guide
Maximum power consumption / current draw400 W / 2 A
Maximum starting torque / force35 Nm / 1,000 N
Rated torque / force20 Nm / 560 N
Speed without load0.25 m/s; six basic speeds of approximately 100 / 85 / 70 / 55 / 45 / 30%
Speed at rated load0.18 m/s
Duty cycleUp to 60 cycles/hour with a short, light gate leaf; reduce according to length and weight
Continuous operationUp to 10 minutes
PinionModule 4, Z18, pitch 12.6 mm, pitch diameter 72 mm
Protection rating / temperatureIP44 / −20 to +50 °C
Operator weight19 kg
Installation clearanceRefer to the dimensioned drawing below and the version of the cover actually supplied
Auxiliary accessory power supply24 V DC, 100 mA total; + left SbS, − right STOP, as shown in the diagram
OGI24 V, max. 4 W; programmable function
Radio receiverOptional, for the SM connector
Backup powerCompatible PS124 / PSS124 with the appropriate cable; alternatively, Solemyo when the mains supply is disconnected

RUN1500 operator dimensioned drawing – length 400 mm, width 255 mm, height 390 mm

The cover protects the operator in normal outdoor conditions; IP44 does not mean it can be submerged. During installation, leave enough space to open the cover, carry out maintenance, and release the operator. Take electrical and electronic components and batteries to an appropriate collection point; do not dispose of them with ordinary household waste.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]