NICE Moonclever MC424LR10 is a control unit for automating single-leaf, or double-leaf gates. Operators compatible with it must have a 24 V DC.
- The control unit synchronously opens and closes (and stops) a double-leaf gate. It can also operate a single gate motor.
- Suitable for gates that open inward or outward.
- Wireless remote control remote control (with antenna up to 150–200 m).
- The gate can also be operated by wire using a push button, video intercom or a range of other accessories (discover all the ways to open your gate).
- Safe operation thanks to:
- the option to connect photocells that protect the passage with an infrared beam. If the beam is interrupted, the gate stops and starts opening (or closing, or stops),
- as well as built-in sensitivity to mechanical obstacles: if the gate hits an object or a person, the motors stop pushing, stop, and reverse,
- and, last but not least, the motors and accessories operate on a safe low voltage of 24 volts.
- With the backup battery connected, the gate can complete up to 10 cycles during a power outage.
- With the electric lock connected, the gate is automatically locked when closed, preventing the leaves from flexing. This is especially useful for longer leaves over 3 m.
- At the press of a button, the control unit moves the motors between the fully open and fully closed positions and stores the end positions in memory.
- Option to reset to factory settings (remote controls are deleted separately).
Compatible only with the specifically listed swing gate operators:
The MC424LR10 control unit includes MCA2R10 control board, which is housed in a standard plastic box Moonclever. It has a built-in radio receiver and also includes an SM connector for connecting an additional radio receiver (SMXI, OXI, ...) from remote controls (Flor, Era Flor, Era One, Era Inti, ...).
Thanks to 24 V technology, it is also suitable for the NICE Solemyo solar system, which provides power even in locations without access to an electricity supply. It is also possible to power the control unit from a NICE PS124 backup battery, which enables several opening and closing cycles of the swing gate for a few hours after a power outage. When standby mode is enabled, the control unit with a connected radio receiver consumes just 2 W (when powered by the PS124 battery, or the Solemyo solar system, consumption is just 0.1 W).
Diagnostics using a diagnostic LED.
The acceleration and deceleration intervals for opening and closing are set automatically after the gate leaf length has been measured. It is also possible to set force, speed, pedestrian opening etc. see programming the drive control unit. Obstacle detection throughout the gate leaf’s movement ensures safe motor operation.
NICE Moonclever MC424LR10 control unit is suitable for the climate in Slovakia and complies with all European safety standards.
Accessories compatible with the NICE Moonclever MC424LR10 control unit
We recommend purchasing compatible optional accessories for the control unit:
| What | Why | Type |
|---|---|---|
| Flashing beacon | The beacon flashes to indicate gate movement—ideal for exits with limited visibility. It also has a built-in antenna for increased remote-control range. | - Era Light (EL24, ELDC) - Lucy (LUCY24) - Moonlight (ML24T) |
| Photocells | They detect obstacles while the gate is closing and stop its movement, preventing it from hitting cars or people. | - Era Photocell (EPS, EPM, EPL) - BF - Moon (MOF, MOFO) |
| Transmitter |
For remote control of the gate. |
- FloR (Flo2R-s, Flo4R-s) |
| Receiver | Not required for remote control of the gate, as the control unit NICE-MCA2R10 already has a receiver built in. | - OXI - SMXI |
| Antenna | For improved remote-control range. | - built into the beacon ML24T, EL24, ELDC - ABFKIT antenna only, or ABF |
| Keypad | If you forget your remote control, or if many vehicles or people visit your premises and you don't want to give everyone a remote or open the gate manually. | - EDSWG |
Manual for the NICE Moonclever MC424LR10 control unit
The NICE Moonclever MC424LR10 control unit manual is currently available for download in English only:
Manual for the NICE Moonclever MC424LR10 control unit
Installing the NICE Moonclever MC424LR10 control unit
Installing the control unit in a standard mounting box Moonclever is installed using four screws:
![]() |
![]() |
| 1. Unscrew the plastic cover screws | 2. Secure the control unit box with four wall plugs |
|---|
Typical (optional) wiring configuration for the drive control unit and accessories is as follows:
List of accessories
|
|
Note on photocells:
| 5. | PHOTO | The photocells have no effect while the gate is opening. If their beam is interrupted while the gate is closing, the gate reverses and opens. |
|---|---|---|
| 6. | PHOTO1 | The photocells stop the gate while it is opening or closing. |
| 7. | PHOTO2 | The photocells have no effect while the gate is closing. If their beam is interrupted while the gate is opening, the gate reverses and closes. |
Wiring the NICE Moonclever MC424LR10 control unit
Before connecting, disconnecting or changing any wiring, remember to drive disconnect the power supply to both the mains and any accessories, either at the circuit breaker, by removing the power supply fuse, or by disconnecting the backup battery. Wait until all the LEDs go out.
...to the mains
For the drive to work, simply connect the power supply to the drive control unit .
- Unscrew the cable clamp C
- Connect the live wire to terminal block A to the terminal marked L
- Connect the neutral wire to terminal block A, to the terminal marked N
- Screw the earth wire to point B marked T
...to the accessories
The control unit can be connected to the following accessories:
| A. | Power supply connector, 24 V |
|---|---|
| B. | Connector for NICE PS124 backup battery, or the NICE Solemyo solar system. |
| C. | Fuse for the F 2A control unit |
| D. | NICE SM connector NICE SM for radio receiver (e.g. SMXI, OXI) |
| E. | Connection of primary motor M1 (starts first during closing; if it is not connected, the control unit automatically identifies the gate as a single-leaf gate) |
| F. | Connection of secondary motor M2 (starts first during opening) |
| G. | Output for beacon |
| H. | Output for gate status indicator, or electric lock (depending on the settings in programming) |
| I. | 24 V DC power supply for accessories, Standby mode and PHOTOTEST |
| L9...L13. | Input LEDs |
| OK | "OK" LED |
| L1..L8 | Programming LEDs |
| LR | Remote control programming LED |
| M. | Inputs for connected devices, photocells, buttons, etc. |
| N. | Antenna input (e.g. ABF, ABFKIT, or built-in in the ML24T flashing light) |
| O. | Motor model selection switches |
| Q. | IBT4N connector for diagnostics and programming (for professional use) |
| R. | Power supply fuse |
| S. | Power supply terminal block (L=live, N=neutral) |
| T. | Earth connection |
| U. | Power cable holder |
| P1,P2,P3 | Programming buttons |
| P4. | Remote control programming button |
Standard wiring diagrams:
The wiring to the control unit terminal blocks can be connected in three main ways:
| With standby mode | Without standby mode | |
|---|---|---|
| Without PHOTOTEST | With PHOTOTEST | |
![]() |
![]() |
![]() |
| One minute after the last operation, the control unit switches to energy-saving mode, turning off all inputs and outputs. When standby mode is active, this is indicated by the OK LED (LED P1), which flashes more slowly (once every 4 seconds) than usual (once per second). Standby mode is required when connecting the NICE Solemyo solar system, as well as when connecting the NICE PS124 backup battery. | Wiring without standby mode and without PHOTOTEST. The device uses power at the standard rate, and an operation will start even if one of the safety photocells has failed. | PHOTOTEST checks that the FOTO, FOTO1 and FOTO2 photocells are working correctly before an operation starts (i.e. each photocell is powered separately). If any photocell is not working correctly, the operation will not start. If any of the photocells are not used, the terminal must be connected to input no. 8 (Common). |
Wiring with standby mode is standard; it is only disabled when wiring with PHOTOTEST. This means that either standby mode or PHOTOTEST is enabled, or neither is enabled.
Wiring to the individual terminals
NICE MCA2 control unit for the NICE Moonclever MC424L provides the following inputs and outputs for accessories:
| Input | Purpose | Description | Cable type |
|---|---|---|---|
| L-N-I | Power supply | Main power supply. | 3×1,5mm2 |
| 1-3 | Motor M1 | Power supply of the M1 motor. | 3×1,5mm2 |
| 1-3 | Motor M2 | Power supply of the M2 motor (if it is not connected, the control unit will automatically identify the gate as a single-leaf gate). | 3×1,5mm2 |
| 4-5 | Flashing light | Output for one warning light NICE LUCY24 (or NICE ML24T) with one 24V 25W bulb. | 2×1mm2 |
| 6-7 | S.C.A. gate indicator, or electric lock |
Connection to the S.C.A. open-gate indicator 24 Vdc, maximum 5W or electric lock 12Vac, maximum 25VA. |
S.C.A.: 2×0,5mm2 Electric lock: 2×1mm2 |
| 8 |
+24 Vdc (plus +) |
Two mutually exclusive uses: If neither standby mode nor PHOTOTEST is used, this input is not used; input no. 11. |
1×0.5mm2 |
| 9 | 0 Vdc (minus -) |
0 Vdc power supply (minus) for accessories | 1×0.5mm2 |
| 10 |
24 Vdc (plus +) |
Used as the power supply for accessories (24 Vdc, max. 200mA), without standby mode. If standby mode is used, this input is not used; input no. 8. +24 Vdc power supply, max. 100mA, for RX photocells (receiver) when using PHOTOTEST; if PHOTOTEST is not used, it powers all photocells. |
1×0.5mm2 |
| 11 | Common input | Common input for accessories (+24 Vdc); used when standby mode is not enabled. | 1×0.5mm2 |
| 12 | STOP |
Input for devices that stop gate movement. The following devices can be connected:
|
1×0.5mm2 |
| 13 | PHOTO | Input for safety devices, e.g. photocells, safety edges. An interruption during operation causes the gate leaf to reverse or stop. Normally closed devices are connected here. | 1×0.5mm2 |
| 14 | PHOTO1 | Input for safety devices, e.g. photocells, safety edges. An interruption during operation causes the gate leaf to reverse or stop. Normally closed devices are connected here. | 1×0.5mm2 |
| 15 | Step-by-step | Input for devices that control gate movement step by step (see Gate movement step-by-step control). Normally open devices (NO) can be connected. | 1×0.5mm2 |
| 16 | AUX | Auxiliary input. | 1×0.5mm2 |
| 17-18 | Antenna | Input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. NICE ML24T, or a separate external antenna can be used NICE ABFKIT. | Shielded coaxial cable: RG58 |
Wiring a key switch
Control unit NICE Moonclever MC424L is compatible with all key switches in our range. The wiring can be carried out in at least two standard ways:
| STOP and Step-by-step | Step-by-step and auxiliary input |
|---|---|
![]() |
![]() |
| Turning the key to the left immediately stops gate movement. Turning it to the right steps through the gate movement commands. Note: if you want standby mode, connect ALT to terminal no. 8 instead of terminal no. 11. |
Turning the key to the left executes the command programmed for the auxiliary input (partial opening of one gate leaf, partial opening of both gate leaves, open, close, execution PHOTO2). Turning it to the right steps through gate movement. |
Wiring the STOP input
Control unit NICE Moonclever MC424L can be programmed to recognize the STOP input in two ways:
- Normally closed contacts (NC) - devices that open the contact when triggered, thereby instructing the control unit to stop the gate
- Devices with a constant resistance of 8.2 kΩ? (e.g. safety edges) - the control unit monitors the resistance and stops the gate if its value deviates from the standard value. Normally closed contacts (NC), normally open contacts (NO), and devices with a constant resistance of 8.2 kΩ? (e.g. safety edges) can be combined in this way according to the following table:
|
|
Type of first device | |||
| NO | NC | 8.2 kΩ? | ||
|---|---|---|---|---|
| Type of the second device |
NO | ![]() |
![]() |
![]() |
| NC | ![]() |
![]() |
![]() |
|
| 8.2 kΩ? | ![]() |
![]() |
||
Wiring the S.C.A. input – gate-open indicator or electric lock
Two options can be programmed for this input:
| 1. Gate-open indicator | 2. Electric lock |
|---|---|
![]() |
![]() |
| The bulb connected to the S.C.A. input flashes slowly while the gate is opening and quickly while it is closing. The bulb stays on while the gate is open and turns off when the gate is closed. This behavior can be configured. | At the same time, each time the gate opens, a release signal is sent to the electric lock for three seconds. |
Control unit fuses
The operator contains two fuses: one for the power supply (type: T 1A 250V) and one for the control unit (type F 2A 250V).
Operator photocells
Coming soon.
Starting up the control unit
After connecting the control unit to the power supply, all LEDs should flash rapidly for a few seconds, after which the following status should be displayed:
- Voltage approx. 30 Vdc (when using a backup battery 24 Vdc) at inputs 9–10.
- LED P1 flashes at one-second intervals. If an input has changed, the LED will flash quickly twice in succession.
- The LEDs for normally closed contacts (NC) will be on, while those for normally open contacts will be off, as shown in the image:

The LEDs will light according to the following legend:
Input Input type LED status STOP STOP NC L1 on Constant resistance of 8.2 kΩ? L1 on PHOTO NC L2 on PHOTO1 NC L3 on Step-by-step NO L4 offon AUX NO – Partial opening I L5 offon NO – Partial opening II L5 offon NO – Open L5 offon NO – Close L5 offon NC – PHOTO2 active L5 on - The individual LEDs should turn on and off as the status of the devices connected to them changes.
- After pressing the P2 button both motors should briefly open the gate, with the primary leaf moving first. Stop the operation by pressing the P2 button again. If the leaves do not start opening but remain still, or start closing, the polarity of the motors must be reversed. If the secondary leaf moves first, set the jumper as shown in the image:
Primary leaf, motor M2 Primary leaf motor M1 

Gate leaf movement evaluation
For the gate to operate correctly (specifically, to calculate the acceleration and deceleration distances and partial opening), the control unit must determine the length of the gate leaves’ opening arc itself. During this operation, it moves the gate leaves from stop to stop using the motors and determines the length of the gate’s opening travel.
Note: If you have already completed the gate leaf movement evaluation, you must, before evaluating it again, erase the control unit’s memory.
Before evaluating gate leaf movement, check that the devices connected to the inputs STOP, PHOTO and PHOTO1 are in good working order and correctly connected. If any of them is activated during the evaluation, the process must be repeated. Ideally, the gate leaves should be about halfway open. To achieve this, disengage the motors, manually move the leaves to the half-open position, then re-engage them. After engaging the motor, always move the leaf slightly by hand so the motor engages properly. In principle, however, it does not matter what position the leaves are in before the evaluation.
Initial start-up of the control unit (or evaluation after a reset)
- Set/check the drive model selector switches according to table 2.6 in the control unit manual.
Note: i.e. motor WG2024: 1-up, 2-down, 3-up, 4-up; WG3524: 1-down, 2-down, 3-up, 4-up; TOO3024: 1-up, 2-down, 3-down, 4-up; TOO4524: 1-down, 2-down, 3-down, 4-up; unspecified model: 1-down, 2-up, 3-up, 4-up - Manually disengage the leaves and move them to an intermediate position (open to approx. 45°), re-engage the motors, and pull the leaves slightly so the motors engage properly.
- On the control unit, press and hold the second button (STOP/SET) and the third button (CLOSE) simultaneously; release them when the leaves start moving.
- The leaves will perform the following sequence (the leaf movement evaluation can be interrupted at any time by pressing the STOP button):
- Both leaves open slightly.
Note: If they move in the opposite direction, i.e. close slightly, interrupt the manoeuvre by pressing STOP, disconnect the control unit from the power supply, and reverse the polarity on both motors. If one leaf starts opening and the other starts closing, reverse the polarity only on the motor that started closing. To reverse the polarity, swap the wires between the + (positive) and - (negative) terminals in that motor’s three-terminal block. - The lower leaf closes fully.
Note: If the wrong leaf starts moving (i.e. the upper one), interrupt the manoeuvre by pressing STOP, disconnect the control unit from the power supply, and swap the complete M1 and M2 motor terminal blocks. - The upper leaf closes fully.
- The upper leaf starts opening, followed shortly by the lower leaf.
Note: If the delay is insufficient, it can be changed in the programming menu; see section 5.2.2, LED L6 “Leaf delay”. - Both leaves open fully.
- The lower leaf starts closing, followed shortly by the upper leaf.
- The leaves close fully, and the control unit saves their end positions to memory.
- Done.
All the phases listed above must run one after another without any intervention from you. If any phase does not run correctly, stop it by pressing button P1 and, if necessary, adjust the settings and repeat the process.
Programming the drive control unit
Control unit MC424L allows you to program several functions, either by enabling/disabling a function using level I programming, or by setting a preset parameter using level II programming.
Programming may look a little awkward and confusing at first, but once you understand the two basic principles, you’ll quickly find your way around the menu with a little imagination.
Basically, you need to understand that programming is done using three buttons (buttons P1, P2 and P3) and their corresponding LEDs (LEDs P1, P2 and P3), as well as indicator LEDs L1, L2, L3, L4 and L5.
The functions of the individual buttons and the LED signals depend on the programming level you are in.
MCA2 control unit has three buttons for operating and programming the drive:
![]() |
Button |
|---|---|
| P1 | |
| P2 | |
| P3 |
The control unit allows you to program 1 direct function and 10 functions that can be enabled or disabled and 5 adjustable functions (of which the AUX auxiliary input has a further 5 functions that can be enabled or disabled):
Direct function
There is one direct function, namely setting the gate movement speed, which can be toggled during normal operation (i.e. not programming mode) by pressing button P3:
| Function | On (P3 LED lit) | Off (P3 LED unlit) |
|---|---|---|
| Movement speed | fast speed (default) | slow speed |
Enableable functions
There are 10 functions that can be enabled, and they are set in level I programming. (default values are highlighted in bold):
| Function | On (LED lit) | Off (LED unlit) |
|---|---|---|
| Automatic closing | After the set pause duration the gate starts closing automatically. | The gate moves only when a command is issued using a remote control, using a key switch, a push button, etc. |
| Condominium | This is useful when several users operate the drive and their commands may conflict; for example, one user starts opening the gate while another also wants to open it, but because the gate is already opening, it starts closing, and so on. So, after the first open command, all other commands are ignored until the gate is fully open. | The gate is operated in step-by-step mode: Open > Stop > Close > Stop > Open |
| Pre-flashing | The warning light flashes for 3 seconds before the gate starts moving. | Movement starts immediately, at the same time as the warning light starts flashing. |
| Close after photocell interruption | This is useful only if automatic closing is enabled. After passing through the photocells (i.e. the photocell beam is interrupted and then restored), the gate starts closing after just 4 seconds, for example after a vehicle has exited. | The gate starts closing only after the set pause duration automatic closing. |
| Secondary leaf delay | Sets whether the secondary leaf starts moving with a delay. This is useful if one leaf could scrape against the other while moving. Also when using electric lock. The delay can be set as a percentage in Level II programming. | Both leaves start moving at the same time. |
| Standby mode/Phototest |
Activates the output on terminal no. 8: Standby mode on standby mode, or phototest on phototest. Only one function can be active at a time. Select the function you want to use by following the appropriate wiring diagram. |
Deactivates the output on terminal no. 8: Standby mode off and phototest off. |
| Gate-open indicator/Electric lock | The output on terminals 6–7 will operate as an electric lock, meaning that the lock will release during the first three seconds of gate opening. | The output on terminals 6–7 will operate as a gate-open indicator. The flashing pattern can be set; see Level I programming. Gate-open indicator flashing pattern |
| Resistive STOP input | The connection between the Common input and the STOP input will be set to a constant resistance of 8.2 kΩ (±25%), for example for safety edges. For more information, see STOP input. | You can connect to the STOP input normally closed (NC) devices that stop the gate immediately when the circuit opens. |
| Heavy gate | The drives will treat the gate as heavy, meaning the control unit will adjust acceleration and deceleration accordingly. | The control unit will treat the gate as light. |
| Gate-open indicator flashing pattern | The bulb connected to the S.C.A. input flashes at varying speeds as the gate opens: the closer the gate is to fully open, the faster it flashes; the closer it is to closed, the slower it flashes. | The bulb connected to the S.C.A. input flashes slowly as the gate opens and quickly as it closes. The bulb stays on while the gate is open and turns off when the gate is closed. |
Adjustable functions
There are 5 adjustable functions (default values are shown in bold):
| L1 on | L2 on | L3 on | L4 on | L5 on | none on |
|---|---|---|---|---|---|
| Pause duration – Sets how long after opening the gate should close. Only applies when automatic closing. | |||||
| 5 seconds | 10 seconds | 20 seconds | 40 seconds | 80 seconds | – |
| AUX auxiliary input – Enables or disables 5 additional functions. | |||||
| Partial opening I – opens only the primary leaf fully | Partial opening II – opens both leaves halfway | Open only – cycles through commands in this sequence: Open > Stop > Open | Close only – cycles through commands in this sequence: Close > Stop > Close | FOTO2 photocells – activates the FOTO2 | The AUX input (terminal no. 16) is not used |
| Motor cut-off after closing – After reaching the closing end stop, the motor continues to push briefly to ensure the gate closes fully. This function sets the reverse-run time so the motor does not continue pushing against the leaves when the gate is closed. | |||||
| no cut-off | 0.3 seconds | 0.7 seconds | 1.3 seconds | 2 seconds | – |
| Motor force – The motors are sensitive to friction, wind and fluctuations in the power supply. As a result, these factors may cause them to detect an obstacle when none is present. Increasing the force setting reduces this risk. | |||||
| Low force | Lower force | Medium force | Higher force | High force | Maximum |
| Second leaf delay – Sets the secondary leaf delay as a percentage. The percentage is calculated based on the standard travel distance of the leaf. | |||||
| 5% | 10% | 20% | 30% | 40% | – |
Level I Programming.
The control unit must be in normal mode. You can check this by confirming that the P1 LED is flashing slowly and LED P3 is off.
To enter Level I programming by pressing and holding buttons P1+P2 for 3 seconds until all the LEDs flash. LED P1 stops flashing and stays lit. Great, you are now in Level I programming on the “Screen I". To the “Screen II” you go by pressing button P3 and likewise back to “Screen I". Which “Screen” you are on is indicated by the status of LED P3, see the table.
| Screen I | ||||
|---|---|---|---|---|
| LED P1 is lit, LED P3 is off | ||||
| L1 | L2 | L3 | L4 | L5 |
| Automatic closing | Condominium | Pre-flashing | Close after photocell interruption | Secondary leaf delay |
| Screen II | ||||
| LED P1 is lit, and LED P3 is lit too | ||||
| L1 | L2 | L3 | L4 | L5 |
| Standby mode/Phototest | Open gate indicator/Electric lock | Resistive STOP input | Heavy gate | Open gate indicator flashing interval |
By pressing button P1 you move along the LEDs towards the right.. When you reach the fifth LED L5, you start again from the first LED L1, that is, you cycle through the selection.. The currently selected LED will flash. If the flashing is short, the function is inactive, if the flashing is longer , the function is active. Switch between short and longer flashes by pressing once button P2.
Once you have set all the values to the desired flashing pattern (and therefore activated or deactivated the function), pressing and holding buttons P1+P2 for 3 seconds saves the settings and returns you to normal mode.
Alternatively, if you are happy with everything and do not want to change anything, or are returning from Level II programming, or simply want to exit programming without saving, simply press and hold button P1 for 3 seconds.
You can also enter Level II programming. by pressing and holding button P2 for 3 seconds. First, however, you must select the function whose parameter you want to change.
Programming Level II.
The control unit must be in Level I programming on “Screen I”, which you can verify by checking that LED P1 is lit and LED P3 is off.
Select the function you want to change:
| L1 | L2 | L3 | L4 | L5 |
|---|---|---|---|---|
| Pause duration | AUX input | Motor disconnection after closing | Motor force | Second leaf delay |
Move to the desired LED by repeatedly pressing once button P1, as in Level I programming. To Level II programming you then enter by pressing and holding button P2 for 3 seconds. LED P1 stops lighting up and starts flashing rapidly. Great, you are in Level II programming.
By repeatedly pressing button P2 once, you can select the parameter value you want to set, and then press button P1 once to return to Level I programming.
To save, you must also press and hold the buttons P1+P2 for 3 seconds (while in Level I programming.).
To exit without saving, press and hold only the P1 button for 3 seconds. It's not that complicated, is it?.
The key is to understand that although you are still looking at 5 LEDs and 3 buttons, the LED indicators P1 and P2 tell you where you are in the process. A table of possible states may help:
| LED P1 | ||||
|---|---|---|---|---|
| On | Flashing | Flashing rapidly | ||
| LED P3 |
Off | Level I programming. "Screen I" |
Normal mode |
Level II programming. |
| On |
Level I programming. |
- | - | |
For reference, here is the complete programming diagram (click to open full size):
If you need help, feel free to contact our technical support team for NICE operators.
Connecting additional external devices to the operator
|
If you need to connect additional devices to the operator that require an external power supply (e.g. indicator lighting, key switch, card readers, etc.), connect the device as shown alongside. The supplied voltage is 30 Vdc -30% to +50% (when using a backup battery 24Vdc) with a maximum current of 200mA. |
||||||||||||
Special functions of the control unit
Clearing the memory (resetting) the NICE MC424LR10 control unit
Note: This procedure clears only the control unit's memory; the remote controls will remain stored in it.
- Press and hold the first (OPEN) and second (CLOSE) buttons simultaneously
- When all LEDs L1..L8 start flashing (after approx. 3-4 seconds), release them
- Wait 5 seconds. The control unit will now be restored to factory settings.
To check that the memory has been cleared correctly, disconnect the control unit from the mains (or remove the F1 power fuse) and wait until all the LEDs go out. After reconnecting it to the mains, if the memory has been completely cleared, all the LEDs should flash for about six seconds. If the LEDs flash for only three seconds, the memory probably was not cleared successfully and the procedure must be repeated.
Troubleshooting the operator
If anything is unclear or you have any other issue, feel free to contact our technical support team for NICE operators.
Depending on the nature of the problem
During installation (or if the operator malfunctions), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
No LEDs are lit |
Check that the control unit is receiving power. You can check this by measuring the voltage at inputs 9-10 on the terminal block; it should be approx. 30Vdc, or 24Vdc when powered by a battery. Try testing both fuses and, if necessary, replace them with new ones of the same rating. |
|
LED P1 flashes regularly, but the state of LEDs L1 to L5 does not match the connected devices |
Briefly disconnect the control unit from the mains (or remove the F1 power fuse) and wait until all the LEDs go out; you may be stuck in programming mode. Then check all device connections at inputs 11 to 16. You can disconnect them all and reconnect them one by one to identify the issue. |
|
LED P1 flashes every 4 seconds |
The control unit is in standby mode |
|
The gate-leaf movement learning procedure will not start |
The gate-leaf movement learning procedure will start only if it has not yet been performed or if the memory has not been cleared. If the gate movement has been learned incorrectly, you will first need to erase the memory. |
|
The wing movement learning has never been performed before and yet it will not start, or it behaves abnormally |
First, check that all connected devices and safety devices are working correctly. Make sure that no device is triggered while the gate wing movement is being learned. Before starting the learning procedure, the contact LEDs must be lit correctly and the P1 LED must flash once per second. |
|
The wing movement learning was completed correctly, but the manoeuvre does not start |
Check that the safety device LEDs PHOTO, PHOTO1 and possibly PHOTO2 (if connected), as well as the LEDs for the Step-by-step and AUX auxiliary input devices are on when a movement command is given. If the PHOTOTEST function is enabled but the photocells are not working correctly, the diagnostic LED flashes 4 times. |
|
The gate moves, but stops during travel and starts moving in the opposite direction |
I. The photocells are being triggered. There are several possible causes:
Check the photocell wiring and the corresponding LEDs. II. Another possibility is that the gate is too heavy for the operator, or that it is being obstructed by strong wind. In this case, the operator detects increased current consumption and interprets the situation as an obstacle (the gate can also be stopped by hand). The diagnostic LED flashes once if motor M1 detects the obstacle and twice if motor M2 detects it. There are two solutions: 1. Enable the heavy-gate setting: First level (P1 LED lit): second section (P3 LED lit)
Enable LED L4 Heavy gates
2. Set the ammeter-based sensitivity (i.e. motor force) to minimum sensitivity (i.e. maximum force):
Second level
Set the parameter Ammeter-based sensitivity (motor force) to All LEDs off: level 6 (maximum ammeter setting)
|
Diagnostics using the P2 LED
Coming soon.
Installing the backup battery in the NICE MC424L control unit
NICE PS124 backup battery is not included as standard with the operator, but it can be ordered separately. It is used in the event of a power failure, when it will power the gate operator. The battery is continuously recharged from the mains.
Technical specifications of the NICE Moonclever MC424L control unit
| Model | NICE Moonclever MC424L | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Type description | Electrical control unit for automatic operation of swing gates. Supplied with NICE MCA2 control unit, but without radio receiver. | ||||||||||||||||
| Power supply | 230V (+10% -10%) 50/60Hz | ||||||||||||||||
|
Power consumption |
170W | ||||||||||||||||
| Backup power supply | available to purchase and install NICE PS124 backup battery | ||||||||||||||||
| Flashing light output | for one flashing light 24Vdc with a bulb rated at up to 25W (e.g. NICE Lucy LUCY24, NICE Moonlight ML24T) | ||||||||||||||||
| Status indicator output (S.C.A.) | - for one 24Vdc bulb, max. 5W (output voltage +50% -30%); can control a small relay - or for one 12Vac, max. 25W electric lock |
||||||||||||||||
| PHOTOTEST output | 24Vdc max. 100mA | ||||||||||||||||
| Accessory output | 24Vdc max 200mA | ||||||||||||||||
| STOP input | for normally closed devices and devices with a constant resistance of 8.2KΩ | ||||||||||||||||
| Radio receiver | without receiver, "SM" connector for receivers NICE SMXI, NICE OXI etc. | ||||||||||||||||
| Antenna input | 50Ω for RG-58 coaxial cable (or similar) | ||||||||||||||||
| Operating time | automatic calibration | ||||||||||||||||
| Pause duration | programmable to 5, 10, 20, 40 or 80 seconds | ||||||||||||||||
| Motor power-off after closing | programmable to 0; 0.3; 0.7; 1.3; 2 seconds | ||||||||||||||||
| Leaf delay when opening | programmable to 5, 10, 20, 30 or 40% of the operating time | ||||||||||||||||
| Leaf delay when closing | automatic calibration | ||||||||||||||||
| M1 motor output | for Wingo WG2024, WG3524, WG4024, WG5024 | ||||||||||||||||
| M2 motor output | for Wingo WG2024, WG3524, WG4024, WG5024 | ||||||||||||||||
| Maximum cable lengths |
|
||||||||||||||||
| Operating temperature | -20°C to +50°C | ||||||||||||||||
| Use in saline, acidic and potentially explosive environments | no | ||||||||||||||||
| Protection rating | IP54 | ||||||||||||||||
| Dimensions | 232×310×122 (W×L×H) | ||||||||||||||||
| Weight | 4.1kg |
Warning! Replacement available - new MCA2R30 control unit
The new MCA2R30 control unit replaces the MCA2R10, which was preceded by the MCA2. Control unit NICE MC424LR30 is equipped with the NICE MCA2R30 control unit with a built-in radio receiver. It is compatible with Nice motors: WG2024, WG3524, WG4024, WG5024, TOO3024, TOO4524 and XME2024.
Changes to the NICE MCA2R30 control unit compared with the MCA2R10
- The output order has changed; the outputs themselves are unchanged.
- New connector for connecting the backup battery, using the new cable CABLA11. A new PSS124 backup power supply is also being added.
- Improved diagnostics.
- Lower energy consumption in standby mode.
WARNING
All programming procedures remain unchanged compared with the previous MCA2R10 control unit.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]