NICE Moonclever MC424L - control unit for 24V swing gate operators in the Wingo range
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€226.23 including VAT
| Weight |
|---|
| 1,50 kg |
Description of NICE Moonclever MC424L - control unit for 24V swing gate operators in the Wingo range
Control unit change
The NICE MC424L control unit is no longer manufactured, so when you place your order, we will send you the newer version NICE MC424LR10.
NICE Moonclever MC424L is a control unit for automating single-leaf, or double-leaf gates. Operators compatible with it must have a 24Vdc.
Compatible only with the specifically listed swing gate operators:
MC424L control unit includes the MCA2 control board, which is housed in a standard plastic box Moonclever. Includes an SM type connector for connecting radio receiver (SMXI, OXI,...) from remote controls (Flor, Era Flor, Era One, Era Inti,...).
Thanks to its 24V technology, it is also suitable for the NICE Solemyo solar power system, which provides power even in locations without access to an electricity supply. It is also possible to power the control unit using the NICE PS124 backup battery, which enables several gate opening and closing cycles for a few hours after a power outage. When standby mode is enabled, the control unit with a connected radio receiver uses just 2W (when powered by the PS124 battery, or Solemyo solar power system, consumption is just 0.1W).
Diagnostics using the diagnostic LED.
The acceleration and deceleration intervals for opening and closing are set automatically after the gate leaf length is measured; you can also adjust the force, speed, pedestrian opening etc. See programming the drive control unit. Obstacle detection throughout the gate leaf's movement ensures safe operation of the motors.
The NICE Moonclever MC424L control unit is suitable for the climate conditions in Slovakia and meets all European safety standards.
Accessories compatible with the NICE Moonclever MC424L control unit
We recommend purchasing these optional accessories for the control unit:
| What | Why | Type |
|---|---|---|
| Flashing light | The flashing light signals gate movement by flashing—ideal for exits with limited visibility. It also has a built-in antenna for greater remote-control range. | - Lucy (LUCY24) - Moonlight (ML24T) |
| Photocells | When closing, they detect obstacles and stop the gate—preventing it from hitting cars or people. | |
| Transmitter |
For remote control of the gate. |
- FloR (Flo2R-s, Flo4R-s) |
| Receiver | Required for remote gate operation. | - OXI - SMXI |
| Antenna | For improved remote-control range. | - integrated into the beacon ML24T - ABFKIT antenna only, or ABF |
| Keypad | Useful if you forget your remote control, or if many vehicles or people visit and you don't want to give everyone a remote or open the gate manually. | - MOTXR |
NICE Moonclever MC424L control unit manual
Download the NICE Moonclever MC424L control unit manual here:
NICE Moonclever MC424L control unit manual
Installing the NICE Moonclever MC424L control unit
Installing the control unit in the standard mounting box Moonclever is secured with four screws:
![]() |
![]() |
| 1. Unscrew the plastic cover screws | 2. Secure the control unit box with four wall plugs |
|---|
A typical (optional) wiring setup for the drive control unit and accessories looks like this:
List of accessories
|
|
Note on photocells:
| 5. | PHOTO | The photocells have no effect while the gate is opening. If their beam is interrupted while the gate is closing, they reverse the gate and start it opening. |
|---|---|---|
| 6. | PHOTO1 | The photocells stop the gate while it is opening or closing. |
| 7. | PHOTO2 | The photocells have no effect while the gate is closing. If their beam is interrupted while the gate is opening, they reverse the gate and start it closing. |
Wiring the NICE Moonclever MC424L control unit
Before connecting, disconnecting or changing the wiring, remember to disconnect the power supply to drive both the mains supply and any accessories, either at the circuit breaker, by removing the power supply fuse, or by disconnecting the backup battery. Wait until all the LEDs have gone out.
...to the mains
For the drive to work, you only need to connect the power supply to the drive control unit .
| Connect the live (L) and neutral (N) wires. | Connect the earth wire (I). |
|---|---|
|
top view |
top view |
...accessories
To the control unit the following accessories can be connected:
| A. | Power 24V connector |
|---|---|
| B. | Connection of the primary motor M1 |
| C. | Connector for connecting the NICE PS124 backup battery, or the NICE Solemyo solar system. |
| D. | Control unit fuse, type F 500mA |
| E. | Adjustable jumper to select the primary (first to open) gate leaf |
| F. | Connection of the secondary motor M2 (if it is not connected, the control unit automatically identifies the gate as a single-leaf) |
| G. | Output for the warning light |
| H. | Output for the gate status indicator, or the electric lock (depending on the setting in programming) |
| I. | 24Vdc power supply for accessories, Standby mode and PHOTOTEST |
| L. | Inputs for connected devices, photocells, buttons, etc. |
| L1...L5. | Programming LEDs |
| M. | Antenna input (e.g. ABF, ABFKIT, or integrated in the ML24T warning light) |
| N. | Connector for the NICE SM for radio receiver (e.g. SMXI, OXI) |
| O | Connector for diagnostics and programming (for professional use) |
| P1, P2, P3 | Programming buttons and LEDs |
Standard wiring diagrams:
The wiring to the control unit terminal blocks can be connected in three main configurations:
| With standby mode | Without standby mode | |
|---|---|---|
| Without PHOTOTEST | With PHOTOTEST | |
![]() |
![]() |
![]() |
| One minute after the last operation, the control unit switches to energy-saving mode and turns off all inputs and outputs. Standby mode activation is indicated by the OK LED (LED P1), which flashes more slowly (once every 4 seconds) than usual (once per second). Standby mode is required when using the NICE Solemyo solar system and when connecting a NICE PS124 backup battery. | Wiring without standby mode and without PHOTOTEST. The device draws power at the standard rate, and the gate will operate even if one of the safety photocells fails. | PHOTOTEST checks that the FOTO, FOTO1 and FOTO2 photocells are working correctly before starting an operation (i.e. each photocell is powered separately). If any photocell is not working correctly, the operation will not start. If any photocells are not used, the terminal must be connected to input no. 8 (common). |
Wiring with standby mode is standard; it is disabled only when wiring with PHOTOTEST. Either standby mode or PHOTOTEST can be enabled, or neither.
Wiring to the individual terminals
NICE MCA2 control unit control center NICE Moonclever MC424L provides the following inputs and outputs for accessories:
| Input | Purpose | Description | Cable type |
|---|---|---|---|
| L-N-I | Power supply | Main electrical supply. | 3×1.5mm2 |
| 1-3 | Motor M1 | Power supply of the primary motor M1. | 3×1,5mm2 |
| 1-3 | Motor M2 | Power supply of the secondary motor M2 (if it is not connected, the control unit will automatically identify the gate as single-leaf). | 3×1,5mm2 |
| 4-5 | Flashing light | Output for one warning light NICE LUCY24 (or NICE ML24T) with one 24V 25W bulb. | 2×1mm2 |
| 6-7 | Gate status indicator S.C.A., or electric lock |
Connection to S.C.A. open-gate indicator 24 Vdc, maximum 5W or electric lock 12Vac, maximum 25VA. |
S.C.A.: 2×0,5mm2 Electric lock: 2×1mm2 |
| 8 |
+24 Vdc (plus +) |
Two mutually exclusive uses: If neither standby mode nor PHOTOTEST is used, this terminal is not used; use input no. 11. |
1×0,5mm2 |
| 9 | 0 Vdc (minus -) |
0 Vdc (minus) power supply for accessories | 1×0,5mm2 |
| 10 |
24 Vdc (plus +) |
Used as the power supply for accessories (24 Vdc, maximum 200mA), without standby mode. If standby mode is used, this terminal is not used; use input no. 8. +24 Vdc power supply, maximum 100mA, for RX photocells (receiver) when using PHOTOTEST; if PHOTOTEST is not used, it powers all photocells. |
1×0,5mm2 |
| 11 | Common input | Common input for accessories (+24 Vdc), used when standby mode is not enabled. | 1×0,5mm2 |
| 12 | STOP |
Input for devices that stop gate movement. The following devices can be connected:
|
1×0,5mm2 |
| 13 | PHOTO | Input for safety devices, e.g. photocells, safety edges. An interruption during a manoeuvre reverses movement or stops the gate leaf. Normally closed devices are connected here. | 1×0,5mm2 |
| 14 | PHOTO1 | Input for safety devices, e.g. photocells, safety edges. An interruption during a manoeuvre reverses movement or stops the gate leaf. Normally closed devices are connected here. | 1×0,5mm2 |
| 15 | Step-by-step control | Input for devices that control gate movement step by step (see Step-by-step gate movement). Normally open devices (NO) can be connected. | 1×0,5mm2 |
| 16 | AUX | Auxiliary input. | 1×0,5mm2 |
| 17-18 | Antenna | radio receiver antenna input. The antenna is usually built into the warning light, such as the NICE ML24T, or you can use a separate external antenna NICE ABFKIT. | Shielded coaxial cable: RG58 |
Wiring the key switch
Control unit NICE Moonclever MC424L is compatible with all key switches in our range. Wiring can be carried out in at least two standard ways:
| STOP and Step-by-step | Step-by-step and auxiliary input |
|---|---|
![]() |
![]() |
| Turning the key to the left immediately stops the gate.. Turning it to the right steps through the gate's movement. Note: if you want Standby mode, connect ALT to terminal no. 8 instead of terminal no. 11. |
Turning the key to the left executes the command programmed for the auxiliary input (partial opening of one gate leaf, partial opening of both gate leaves, open, close, execution FOTO2). Turning it to the right steps through the gate's movement. |
Wiring the STOP input
Control unit NICE Moonclever MC424L can be programmed to recognize the STOP input in two ways:
- Normally closed contacts (NC) - devices that open the contact when triggered, thereby sending the control unit a command to stop the gate
- Devices with a constant resistance of 8.2 kΩ (e.g. safety edges) - the control unit monitors the resistance and stops the gate if the resistance deviates from the standard value. Normally closed contacts (NC), normally open contacts (NO), and devices with a constant resistance of 8.2 kΩ can be combined in this way (e.g. safety edges), as shown in the following table:
|
|
First device type | |||
| NO | NC | 8.2 kΩ | ||
|---|---|---|---|---|
| Type of the second device |
NO | ![]() |
![]() |
![]() |
| NC | ![]() |
![]() |
![]() |
|
| 8.2 kΩ | ![]() |
![]() |
||
Wiring the S.C.A. output – gate-open indicator or electric lock
This input can be programmed to operate in one of two ways:
| 1. Gate-open indicator | 2. Electric lock |
|---|---|
![]() |
![]() |
| The light bulb connected to the S.C.A. input flashes slowly while the gate is opening and quickly while it is closing. The light stays on while the gate is open and turns off when the gate is closed. Its operation can be set. | At the same time, each time the gate opens, a signal is sent to the electric lock to release it for three seconds. |
Control unit fuses
Coming soon.
Drive photocells
Coming soon.
Radio receiver for drives
![]() |
NICE Moonclever MC424L control unit is supplied with the NICE MCA2 control unit, which has an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted by from remote controls, and is therefore required to operate the sliding gate remotely using a remote control. |
Starting up the control unit
After connecting the control unit to the power supply, all the LEDs should flash rapidly for a few seconds, after which the following status should be reached:
- Voltage approx. 30 Vdc (when using the backup battery 24 Vdc) at inputs 9-10.
- LED P1 flashes at one-second intervals. If the inputs have changed, the LED will flash rapidly twice in succession.
- The LEDs for normally closed contacts (NC) will be lit, and those for normally open contacts will be off; see the diagram:

The LEDs indicate the following:
Input Input type LED status STOP STOP NC L1 lit Constant resistance 8.2k? L1 lit PHOTO NC L2 lit PHOTO1 NC L3 lit Step-by-step NO L4 offlit AUX NO - Partial opening I. L5 offlit NO - Partial opening II. L5 offlit NO - Open L5 offlit NO - Close L5 offlit NC - PHOTO2 active L5 lit - The individual LEDs should turn on and off as the status of the devices connected to them changes
- After pressing the P2 button both motors should briefly open the gates, with the primary leaf moving first. Stop the movement by pressing the P2 button again. If the leaves do not start opening but remain stationary, or start closing, the motor polarity must be reversed. If the secondary leaf moves first, set the jumper as shown in the diagram:
Primary leaf, motor M2 Primary leaf, motor M1 

Gate leaf movement detection
For the gate movement to function correctly (specifically, to calculate the acceleration and deceleration distances and partial opening), the control unit must determine the opening arc length of the gate leaves itself. During this operation, the drives move the gates from one stop to the other and determine the gate's opening travel time.
Note: If you have already completed the gate leaf movement detection procedure, you must, before running it again, clear the control unit's memory.
Before detecting gate leaf movement, check that the devices connected to inputs STOP, PHOTO and PHOTO1 are working properly and connected correctly. If any of them is activated during detection, the process must be repeated. Ideally, the gate leaves should be approximately halfway open. To do this, release the drives and manually move the leaves to the half-open position, then lock the drives again. After locking the motor, always move the leaf slightly by hand so that the motor engages. In principle, however, the position of the leaves before detection does not matter.
Gate leaf movement detection is automatic and proceeds as follows:
- Press the P2 button
- Both leaves open slightly
- The secondary (lower) leaf closes
- The primary (upper) leaf closes
- The primary (upper) leaf opens
- After the programmed secondary motor delay time the secondary (lower) leaf starts to open. If the delay is unsuitable, press the P2 button and set a suitable delay
- The control unit determines the travel time required to fully open the gate (i.e. until it reaches the mechanical stops)
- Both leaves close completely. The leaves start closing at different times to prevent them from rubbing against each other while closing
- The control unit saves the measured values and the process is COMPLETE.
All the above stages must take place one after another without any intervention on your part. If any stage does not proceed correctly, stop it by pressing the P1 button and, if necessary, adjust the settings and repeat the process.
Programming the drive control unit
The control unit MC424L allows you to program several functions, either by switching a function on or off using Level I programming., or by setting a preset parameter using Level II programming.
Programming may look a little cumbersome and confusing at first, but once you understand two basic principles, you'll quickly find your way around the menu with a little imagination.
Basically, you need to understand that programming is done using three buttons (buttons P1, P2 and P3) and their corresponding LEDs (LEDs P1, P2 and P3), as well as the indicator LEDs L1, L2, L3, L4 and L5.
The functions of the individual buttons and the LED indicators depend on the programming level you are in.
MCA2 control unit has three buttons for operating and programming the drive:
![]() |
Button |
|---|---|
| P1 | |
| P2 | |
| P3 |
The control unit allows you to program 1 direct function and 10 switchable functions and 5 adjustable functions (of which on the AUX input there are a further 5 switchable functions):
Direct function
There is one direct function, namely the gate operating speed, which can be switched in normal operating mode (i.e. not in programming mode) by pressing button P3:
| Function | On (P3 LED lit) | Off (P3 LED not lit) |
|---|---|---|
| Operating speed | fast speed (default) | slow speed |
Switchable functions
There are 10 switchable functions, configured in Level I programming. (default values are highlighted in bold):
| Function | On (LED lit) | Off (LED not lit) |
|---|---|---|
| Automatic closing | After the set pause duration the gate starts closing automatically. | The gate moves only when a command is given using a remote control, using a key switch, a push button, etc. |
| Condominium mode | This is useful when several users operate the drive and their commands could conflict—for example, one user starts opening the gate and another also requests that it open, but because it is already opening, it starts closing, and so on. After the first open command, all subsequent commands are ignored until the gate is fully open. | The gate is operated in step-by-step mode: Open > Stop > Close > Stop > Open |
| Pre-flashing | The warning light flashes for 3 seconds before the gate starts moving. | Movement starts immediately, at the same time as the warning light starts flashing. |
| Close after photocell interruption | This is useful only when automatic closing. After passing through the photocells (i.e. the photocell beam is interrupted and then restored), the gate starts closing after just 4 seconds, for example after a vehicle has passed through. | The gate starts closing only after the set pause duration for automatic closing has elapsed.. |
| Delay for the secondary leaf | Sets whether the secondary leaf starts moving with a delay. This is useful if one leaf might scrape against the other as it moves. Also when using an electric lock. The delay can be set as a percentage in Level II programming. | Both leaves start moving at the same time. |
| Standby mode / photo test |
Activates the output on terminal no. 8: Enabled standby mode, or enabled photo test. Only one function can be active at a time. Select which one to use by following the appropriate wiring diagram. |
Deactivates the output on terminal no. 8: Standby mode disabled and photo test disabled. |
| Open gate indicator / electric lock | The output on terminals 6–7 will operate an electric lock, meaning that the lock will release during the first three seconds of gate opening. | The output on terminals 6–7 will operate the open gate indicator. The flashing pattern can be set; see Level I programming. Variable flashing of the open gate indicator |
| Resistive STOP input | The link between the common input and the STOP input will be set to a constant resistance of 8.2 kΩ (±25%), for example for safety edges. For more information, see STOP input. | You can connect to the STOP input normally closed (NC) devices, which immediately stop the gate if the circuit opens. |
| Heavy gate | The drives will treat the gate as a heavy gate, meaning the control unit will adjust acceleration and deceleration accordingly. | The control unit will treat the gate as a light gate. |
| Variable flashing of the open gate indicator | The bulb connected to the S.C.A. input flashes irregularly while the gate is opening—the closer the gate is to fully open, the faster it flashes; the closer it is to fully closed, the slower it flashes. | The bulb connected to S.C.A. input It flashes slowly when the gate is opening and quickly when it is closing. When the gate is open, the bulb is lit; when the gate is closed, the bulb is off. |
Adjustable functions
There are 5 adjustable functions (default values are shown in bold):
| L1 lit | L2 lit | L3 lit | L4 lit | L5 lit | none lit |
|---|---|---|---|---|---|
| Pause duration – Sets how long after opening the gate should close. Only applies when automatic closing. | |||||
| 5 seconds | 10 seconds | 20 seconds | 40 seconds | 80 seconds | – |
| AUX auxiliary input – Enables or disables 5 additional functions. | |||||
| Partial opening I – opens only the primary leaf fully | Partial opening II – opens both leaves halfway | Open only – cycles through the commands Open > Stop > Open | Close only – cycles through the commands Close > Stop > Close | FOTO2 photocells – activates the photocell function FOTO2 | AUX input (terminal no. 16) is not used |
| Motor cutoff after closing – After reaching the end stop while closing, the motor continues to push briefly to ensure the gate closes fully. This function sets the reverse run time so the motor does not continue pushing against the leaves while the gate is closed. | |||||
| no cutoff | 0.3 seconds | 0.7 seconds | 1.3 seconds | 2 seconds | – |
| Motor force – The motors are sensitive to friction, wind and fluctuations in the power supply. As a result, these conditions can cause them to detect an obstacle when there isn't one. Increasing the force setting eliminates this risk. | |||||
| Low force | Lower force | Medium force | Higher force | High force | Maximum |
| Secondary leaf delay – Sets the percentage delay of the secondary leaf. The percentage is calculated based on the standard travel distance of the leaf. | |||||
| 5% | 10% | 20% | 30% | 40% | – |
Level I programming.
The control unit must be in normal mode. You can check this by confirming that LED P1 flashes slowly and LED P3 is off.
To enter Level I programming, then press and hold buttons P1+P2 for 3 seconds until all the LEDs flash. LED P1 stops flashing and stays lit. Great, you are now in Level I programming. on “Screen I". To “Screen IIyou can switch by pressing button P3 and likewise back to “Screen I". The “Screenyou are on is indicated by the state of LED P3; see the table.
| Screen I | ||||
|---|---|---|---|---|
| LED P1 lit, LED P3 off | ||||
| L1 | L2 | L3 | L4 | L5 |
| Automatic closing | Condominium | Pre-flashing | Close after photocell interruption | Secondary leaf delay |
| Screen II | ||||
| LED P1 lit, LED P3 also lit | ||||
| L1 | L2 | L3 | L4 | L5 |
| Standby mode/Phototest | Open gate indicator/Electric lock | Resistive STOP input | Heavy gate | Open gate indicator flashing rate |
Pressing button P1 moves through the LEDs toward the right. When you reach the fifth LED L5, you start again from the first LED L1, i.e. as if you were cycling through the options. The currently lit LED will flash. If the flashing is short, the function is inactive, if the flashing is longer the function is active. Switch between short and long flashing by pressing once press the P2 button once.
Once you have set all the values to the desired flashing pattern (and therefore activated or deactivated the function), press and hold buttons P1+P2 for 3 seconds to save the programming and return to normal mode.
Alternatively, if you are happy with everything and do not want to change anything, or are returning from Level II programming, or simply want to exit programming without saving, simply press and hold the P1 button for 3 seconds.
You can also enter Level II programming. by pressing and holding the P2 button for 3 seconds. First, however, you must select the function whose parameter you want to change.
Level II Programming.
The control unit must be in Level I programming on “Screen I”, which you can confirm by checking that LED P1 is lit and LED P3 is off.
Select the function you want to change:
| L1 | L2 | L3 | L4 | L5 |
|---|---|---|---|---|
| Pause duration | AUX input | Motor shutdown after closing | Motor force | Delay of the second leaf |
Select the desired LED by pressing once repeatedly the P1 button, as in Level I programming. You will then enter Level II programming by pressing and holding the P2 button for 3 seconds. LED P1 will stop glowing and start flashing rapidly. Congratulations, you are in Level II programming.
By repeatedly pressing the P2 button you can select the parameter value you want to set, then press the P1 button once to return to Level I programming.
To save, you must also press and hold the buttons P1+P2 for 3 seconds (while in Level I programming).).
To exit without saving, press and hold 3 for the P1 button.
It’s not that complicated, is it? The key is to understand that although you are always looking at 5 LEDs and 3 buttons, the LED indicators tell you where you are. P1 and P2 show you your current status. This table of possible states may help:
| LED P1 | ||||
|---|---|---|---|---|
| On | Flashing | Flashing rapidly | ||
| LED P3 |
Off | Level I programming. "Screen I" |
Normal mode |
Level II programming. |
| On |
Level I programming. |
- | - | |
For reference, here is the complete programming diagram (Click to view full size):
If you need help, feel free to contact our technical support team for NICE drives.
Connecting additional external devices to the drive
|
If you need to connect additional devices to the operator that require an external power supply (e.g. indicator lighting, key switch, card readers, etc.), connect the device as indicated alongside. The supplied voltage is 30 Vdc -30% to +50% (when using backup battery 24Vdc) with a maximum current of 200mA. |
||||||||||||
Special control unit functions
Erasing the memory
- Disconnect the control unit from the mains (or remove the power fuse F1) and wait until all the LEDs go out.
- On the control unit, press buttons P1 and P2 and hold them down (the control unit should remain disconnected from the power supply)
- While holding buttons P1 and P2, connect the control unit to the mains (or insert the power fuse)
- Exactly after 3 seconds release the buttons (that is, during the third second)
- If the erasure process was successful, all the LEDs will go out for one second. If this does not happen and the LEDs keep flashing, you must repeat the erasure process from the beginning.
To check that the memory has been erased correctly, disconnect the control unit from the mains (or remove the power fuse F1) and wait until all the LEDs go out. After reconnecting it to the mains, if the memory has been completely erased, all the LEDs should flash for approximately six seconds. If the LEDs flash for only three seconds, the erasure was probably unsuccessful and must be repeated.
Troubleshooting the operator
If anything is unclear or you have any other problem, feel free to contact our technical support for NICE operators.
Depending on the nature of the problem
During installation (or if the operator fails), you may encounter some of the following problems:
|
Problem |
Possible solution |
|---|---|
|
No LED is lit |
Check that the control unit is receiving power. You can check this by measuring the voltage at inputs 9–10 on the terminal block; it should be approximately 30Vdc, or 24Vdc when powered by the battery. Try testing both fuses and, if necessary, replace them with new fuses of the same rating. |
|
LED P1 flashes regularly, but the status of LEDs L1 to L5 does not correspond to the connected devices |
Disconnect the control unit from the mains briefly (or remove the power fuse F1) and wait until all the LEDs go out; you may be stuck in programming mode. Then check all device connections at inputs 11 to 16. You can disconnect them all and reconnect them one at a time to identify the issue. |
|
LED P1 flashes every 4 seconds |
The control unit is in standby mode |
|
The gate leaf movement learning phase will not start |
The gate leaf movement learning phase starts only if it has not already been performed or if the memory has not been erased. If the gate movement was learned incorrectly, you will first need to erase the memory. |
|
The gate leaf movement learning phase has never been performed, but still will not start or behaves abnormally |
First, check that all connected devices, including safety devices, are working correctly. Make sure that no device is activated during the gate leaf movement learning phase. Before starting the learning procedure, the contact LEDs must be lit correctly and LED P1 must flash once per second. |
|
The gate leaf movement learning phase completed successfully, but the operation does not start |
Check that the LEDs for the safety devices PHOTO, PHOTO1 and PHOTO2 (if connected), as well as the LEDs for the Step-by-step and AUX auxiliary input devices are on when the movement command is given. If the PHOTOTEST function is enabled but the photocells are not working correctly, the diagnostic LED will flash 4 times. |
|
The gate moves, but stops during movement and starts moving in the opposite direction |
I. The photocells are being triggered. There are several possibilities:
Check the photocell connections and the corresponding LEDs. II. Another possibility is that the gate is too heavy for the operator or is being obstructed by strong winds. In this case, the operator detects increased current draw and interprets the situation as an obstacle (the gate can also be stopped by hand). The diagnostic LED flashes once if motor M1 detects an obstacle and twice if motor M2 detects an obstacle. There are two solutions: 1. Enable the heavy gate setting: First level (P1 LED lit): second part (P3 LED lit)
Activate LED L4 Heavy gates
Second level
In the parameter Ammeter sensitivity (motor force) set to All LEDs off: level 6 (max. ammeter sensitivity)
|
Diagnostics using the P2 LED
Coming soon.
Installing a backup battery in the NICE MC424L control unit
NICE PS124 backup battery is not included as standard drive, but it can be ordered separately. It is used in the event of a power outage, when it will power the gate drive. The battery is continuously recharged from the mains.
Technical specifications of the NICE Moonclever MC424L control unit
| Model | NICE Moonclever MC424L | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Description | Electrical control unit for automatic operation of swing gates. Supplied with NICE MCA2 control unit, but without radio receiver. | ||||||||||||||||
| Power supply | 230V (+10% -10%) 50/60Hz | ||||||||||||||||
|
Power consumption |
170W | ||||||||||||||||
| Backup power supply | available to purchase and install NICE PS124 backup battery | ||||||||||||||||
| Beacon output | for one beacon 24Vdc with a bulb rated up to 25W (e.g. NICE Lucy LUCY24, NICE Moonlight ML24T) | ||||||||||||||||
| Indicator output (S.C.A.) | - for one 24Vdc bulb rated up to 5W (output voltage +50% -30%); can control a small relay - or for one 12Vac bulb rated up to 25W electric lock |
||||||||||||||||
| FOTOTEST output | 24Vdc max. 100mA | ||||||||||||||||
| Accessory output | 24Vdc max. 200mA | ||||||||||||||||
| STOP input | for normally closed contacts and devices with a constant resistance of 8.2K? | ||||||||||||||||
| Radio receiver | without receiver; "SM" connector for receivers NICE SMXI, NICE OXI etc. | ||||||||||||||||
| Antenna input | 50? for RG-58 coaxial cable (or similar) | ||||||||||||||||
| Operating time | automatic detection | ||||||||||||||||
| Pause duration | programmable to 5, 10, 20, 40 or 80 seconds | ||||||||||||||||
| Motor shutdown after closing | programmable to 0; 0.3; 0.7; 1.3 or 2 seconds | ||||||||||||||||
| Leaf delay during opening | programmable to 5, 10, 20, 30 or 40% of the operating time | ||||||||||||||||
| Leaf delay during closing | automatic detection | ||||||||||||||||
| M1 motor output | for Wingo WG2024, WG3524, WG4024, WG5024 | ||||||||||||||||
| M2 motor output | for Wingo WG2024, WG3524, WG4024, WG5024 | ||||||||||||||||
| Maximum cable lengths |
|
||||||||||||||||
| Operating temperature | -20°C to +50°C | ||||||||||||||||
| Use in salty, acidic and potentially explosive environments | no | ||||||||||||||||
| Protection class | IP54 | ||||||||||||||||
| Dimensions | 232×310×122 (w×l×h) | ||||||||||||||||
| Weight | 4.1kg |