NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range
NICE-MC424LR30
in stock
€180.37 excluding VAT
€221.86 including VAT

 pcs
Weight
1,50 kg

Description of NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range

NICE MC424LR30 is a control unit for automating single-leaf, or double-leaf gates. Operators compatible with it must have a power supply of 24 Vdc. Download the manual >>

Control unit NICE MC424LR30 is equipped with a control unit NICE MCA2R30 with a built-in radio receiver.

The new MCA2R30 control unit

The new MCA2R30 control unit replaces the MCA2R10, which was preceded by the MCA2. It is compatible with Nice motors: WG2024, WG3524, WG4024, WG5024, TOO3024, TOO4524 and XME2024.

Changes to the NICE MCA2R30 control unit compared with the MCA2R10

  • The outputs are in a new order, but are otherwise unchanged. 
  • A new connector for connecting the backup battery, using the new cable CABLA11. A new PSS124 backup power supply is also being added.
  • Improved diagnostics.
  • Lower power consumption in standby mode.

WARNING

All programming procedures remain unchanged compared with the older MCA2R10 control unit.

Programming the NICE MC424LR30 control unit

Do you have a control unit MC424LR30 with an MCA2R30 board, for example with Wingo WG2024 or WG3524 operators? Below, you’ll find out how to teach the gate to open and close, set its functions, and pair an INTI2 remote control. Each is done separately. So, if you only want to add a remote control, you can go straight to pairing.

1. What the buttons and LEDs do

LabelUse
Open ▲Opens the gate. During programming, use it to move through the function or value options.
Stop/SetStops the gate. Press and hold to enter programming, where you can use it to turn a function on/off or access its value settings.
Close ▼Closes the gate. During programming, use it to move through the function or value options.
RadioUsed for pairing and deleting remote controls. The LR LED is associated with this button.

During programming, check the LEDs L1–L8. LEDs L9–L13 show the status of the inputs, while the LR LED is for the remote-control receiver. Also note the programming level: for example, L1 at Level I turns on automatic closing, but L1 at Level II sets the time after which the gate should close.

2. Setting the gate travel limits

The control unit needs to detect where the stops are and how far the leaves move. It will therefore open and close the gate by itself. This procedure is for a double-leaf gate.

Before starting, check the wiring, safety inputs, and stops. Set the motor type switches according to the operators you have installed – see Table 5 in the LR30 manual, section 4.4. The kit name alone is not enough to choose the setting.

  1. Unlock the operators as described in their instructions, move the leaves manually to approximately halfway, then lock the operators again. Keep the movement area clear of obstructions and people.
  2. On the control unit, press and hold Stop/Set + Close ▼ for more than 3 seconds. Release the buttons when the learning procedure starts.
  3. The gate will first open briefly. Then the lower leaf will close, followed by the upper leaf. The upper leaf is the one that overlaps the other leaf – it opens first and closes last.
  4. Now wait until both leaves have fully opened and then closed. The control unit will save the measured values and the wiring of the ALT input.
  5. If the leaves move in the wrong direction or order, or put anyone at risk, press Stop/Set. Remove the cause first, then repeat the learning procedure. Before changing the wiring, disconnect the mains power supply and the backup battery.

During learning, let the gate complete its movement. Another command or activation of a safety input will interrupt the learning procedure. If you need to repeat it, do not erase the memory – simply start this procedure again.

3. Level I programming – turning functions on/off

At this level, you only turn functions on or off. For example, you tell the gate to close automatically. You set how many seconds later in Level II.

  1. The gate must be stationary. Press and hold Stop/Set, until L1 starts flashing, then release the button.
  2. Use the Open ▲ / Close ▼ buttons to move to the LED for the function you want to change. The list is in the table below.
  3. Press Stop/Set once, without holding it down. This toggles the function: slow flashing = on (ON), fast flashing = off (OFF).
  4. Do not press anything else; wait for programming to end automatically. To check the setting, enter programming again and check the flashing pattern of the relevant LED. Then test the function on the gate.

Do not wait too long between steps, or programming will end and save the changes made so far. Check whether a function is on by looking at its LED – do not assume they are all off by default.

LEDFunctionWhat it changes
L1Automatic closingWhen on (ON), the gate closes automatically after opening and once the pause time has elapsed. Set the pause time at Level II.
L2Closing after photocell activationWhen on (ON), interruption of the photocell during movement sets the pause time to 4 seconds. This function can close the gate automatically even when L1 is off.
L3Closing after a power failureWhen on (ON), the warning light starts flashing when power is restored, and an open gate closes automatically. That is, even without pressing the remote control.
L4Standby / PhototestON = energy-saving Standby mode, OFF = Phototest. Choose according to how the photocells are wired. If the operator is powered only by Solemyo, Standby must be enabled.
L5Electric lock / OGION = OGI open-gate indicator, OFF = electric lock. Set this according to what is connected to the output.
L6Pre-flashing warning lightON: the warning light starts flashing 3 seconds before movement. OFF: it starts flashing when movement begins.
L7Apartment block modeWhen on (ON), pressing the remote control again will not interrupt opening. The safety inputs remain active.
L8Light / heavy gateON = heavy gate, OFF = light gate. This setting changes the operators’ acceleration and deceleration.

4. Level II programming – time, speed, and other settings

Here, instead of choosing on/off, you select a specific value. For example, whether the gate should close after 30 or 60 seconds. First choose what you want to set, then choose the value you want to assign to it.

  1. Press and hold Stop/Setuntil L1 starts flashing, then release the button.
  2. Use the Open ▲ / Close ▼ buttons to move to the LED for the parameter you want to set—for example, L1 for the pause duration.
  3. Press Stop/Set again and hold it. After about 3 seconds, the LED for the current value will light up.
  4. Keep holding Stop/Set while using the Open ▲ / Close ▼ buttons to select a new value.
  5. Only then release Stop/Set. Wait for programming to finish. To check a value, repeat the steps to enter the settings, but do not change it.
LEDWhat you are settingAvailable values
L1Pause before closingL1–L8 values: 5, 15, 30, 45, 60, 80, 120, 180 seconds.
L2AUX inputL1: partial opening of one gate leaf; L2: partial opening of both; L3: opening; L4: closing; L5: PHOTO2; L6: Stop; L7/L8: input with no function assigned. When selecting PHOTO2, the photocell wiring must also be correct.
L3Motor speedSelect a combination of opening and closing speeds. See Table 8 in the manual for the available options.
L4Pressure release after closingHow long the gate operator briefly reverses after closing. L1: no reverse movement; L2–L8: 0.2 to 1.4 seconds in 0.2-second increments.
L5Force / obstacle sensitivityL1 = lowest force and highest sensitivity; L8 = highest force and lowest sensitivity. If the gate is sticking, fix the mechanical issue first; do not simply increase the force. After changing the force, verify the result by measurement.
L6Gate-leaf delayL1–L8: 0, 5, 10, 15, 20, 30, 40, 50% of the closing travel time. The delay during opening is half as long.
L7Maintenance intervalThe number of movements after which the control unit should issue a maintenance reminder. Set this according to the agreed gate maintenance schedule.
L8Fault historyThere are no settings to change here. View the results of the gate’s last eight movements.

Example: You want the gate to close automatically after 60 seconds
First, enable L1 (automatic closing) in Level I. Then enter Level II, select L1 (pause duration), and, while holding Stop/Set, move to L5 (60 seconds). Release Stop/Set and wait for programming to finish.
These are two separate settings. Changing the time alone will not enable automatic closing. And if L2 “Close after photocell” is also enabled, triggering the photocell can shorten the pause to 4 seconds.

All values are listed in Table 8 of the LR30 manual, pages 14–16. After changing the speed, force, delay, or safety functions, test the gate’s movement and stopping; verify the force limitation by measurement.

5. Pairing a NICE INTI2 remote control

These instructions apply to the receiver built into the MCA2R30 control board. If you have added a separate plug-in receiver, follow its instructions. Want to add a second remote control? Do not delete anything or relearn the gate travel; just pair the remote.

Pairing both buttons at once – Mode 1

  1. On the control unit, press and hold Radio. When the LRLED lights up, release the button.
  2. Within 10 seconds press and hold any button on the INTI2.
  3. When LR flashes 3 times slowly, the remote has been saved and you can release the button.
  4. You can add another remote within the next 10 seconds by repeating the same steps from step 2. If you are not adding another remote, wait for pairing to finish, then test both buttons. Keep the gate’s travel area clear.

The first button will operate in step-by-step mode (SbS / Passo-Passo), and the second in AUX. The function of the second button depends on the L2 setting in Level II. If partial opening is selected there, it works when the gate is closed. In any other position, this command works in step-by-step mode.

Pairing one button with a selected function – Mode 2

  1. Press Radio (without holding it) as many times as the function you want to pair: 1× step-by-step, 2× AUX, 3× open, 4× close.
  2. Within 10 seconds, press and hold the INTI2 button you want to assign the function to.
  3. When LR flashes 3 times slowly, release the button. To set another button, start again from step 1.

Remote not paired? Check how many times LR flashes: 1 short flash = the remote is already stored; 6 flashes = incompatible radio coding; 8 flashes = memory full. If the memory is locked, first follow section 6.7 of the manual. Do not delete all remotes just because one could not be added.

6. Clearing settings – reset

What is cleared by a reset?
Learned limit positions, the ALT input setting, Level I and Level II settings, and the movement counter. Paired remotes remain stored. So do not reset the unit for a routine function change or when adding a remote.

  1. Press and hold Open ▲ + Close ▼ together for about 3 seconds.
  2. When L1–L8 light up, release the buttons.
  3. L1–L8 will flash rapidly for about 3 seconds. This confirms that the settings have been cleared.

After resetting, relearn the gate travel, set the functions, and test the gate and safety inputs. Remotes are deleted using a separate procedure; this reset will not delete them.

7. What to test after setup

Test opening and closing: do the leaves move in the right direction and in the right order, stop at the end stops, and respond to the photocells and ALT input? Also check both remote-control buttons and automatic closing, if you enabled it. The force limitation must be verified by measurement. If something does not work, stop the gate and fix the cause—do not disable the photocells or other safety devices.

Wiring diagrams and further settings are in the Slovak Nice manual IDV0619A00SK. The relevant sections for these instructions are 4.3–4.5, 5, and 6. The Wingo motors themselves are installed according to their separate instructions.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range

Product: NICE Moonclever MC424LR30 – control unit for 24 V swing gate operators in the Wingo range
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.