Description of NICE M-Fab MFAB3000 - standalone underground operator for a swing gate leaf up to 3.5 m / 600 kg
NICE M-FAB MFAB3000 is a standalone underground non-reversible drive motor for one gate leaf, with a 230 V AC motor. It does not include a control unit; for a new setup, use NICE MC800 with MCA5R30 board. Two motors and one compatible control unit are required for a double-leaf gate.
The underground drive is concealed beneath the hinge axis, keeping the gate leaf looking clean. It is also suitable where there is no room for a linear or articulated-arm drive. Assess the gate's suitability based on its length, weight and usage, not just the motor voltage.
Control unit and compatible accessories
The MC800 controls one or two 230 V motors. The motor power supply, warning light output and low-voltage accessories are separate circuits. Choose the receiver and photocells to match the control unit actually installed; do not apply MCA5R30 procedures to an older board based on the MC800 name alone.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors. Wiring. |
|
| Warning light | Indicates gate movement. The control unit determines the supply and permitted current draw; output specifications. |
Other warning lights Choose according to the voltage and maximum current draw of the FLASH output on the control unit actually installed. |
| Photocells | Protects the passage area depending on position and operating mode. Wiring and setup. |
Connect wired BlueBUS photocell pairs to BLUEBUS. EPMOW requires an IBW radio interface connected to BlueBUS; it is not wired directly like the EPMB. With the FT210B, the transmitter on the gate leaf is battery-powered, while the receiver connects to BlueBUS with two wires. The FT210B also transmits the status of the safety edge. Relay photocells connect to contact inputs, not to BlueBUS. |
| Transmitter | Remote control. The coding type must match the receiver installed; Pairing. | |
| Receiver | Plug-in receiver for the SM control unit connector. OXIBD and OXILR use different radio systems; select transmitters to match the receiver. |
|
| Antenna | Improves remote control reception. Connect the antenna to the installed receiver; for OXIBD, connect it directly to its antenna terminals. | |
| Keypad | Code-based access. The radio model must match the receiver; the wired model must match the interface type. | |
| Key switch | Key-operated control via a voltage-free NO contact to the step-by-step, open or close input. | |
| Card readers | Access via a chip or card using a compatible control unit interface. |
|
| Electric locks | Additional gate leaf locking; lock output. |
|
Motor, housing and release mechanism
| Assembly component | Equipment and purpose |
|---|---|
| MFAB3000 | One 230 V motor with a 2 m cable, connecting arm and mechanical closing stop. |
| Foundation box | MFABBOX made of cataphoresis-coated steel or stainless steel MFABBOXI. The box includes a mechanical opening stop; this is selected separately. |
| Manual release | NICE MEA2 using a key or NICE MEA3 using a lever. A suitable release mechanism is required for manual operation. |
| Controls and safety | MC800, photocells, receiver, remote controls and warning light, depending on the gate configuration; these are not included with the motor alone. |
| Wide opening angle | NICE MEA1 for opening up to 360°; only for leaves up to 2.5 m, with suitable external stops. |
The box can be used for either a right- or left-hand leaf. For a kit, check the number and material of the boxes and whether MEA2/MEA3 is selected; a standalone motor does not automatically mean a complete set.
Gate leaf length and weight
When selecting a new setup, allow for a leaf up to 3 m long. The 600 kg limit applies to a leaf up to 2.5 m long; the permitted weight decreases as the length increases, as shown in the graph. For a leaf over 3 m, including setups listed for up to 3.5 m, confirm the suitability of the specific configuration and installation conditions.
| Selection parameter | Limit |
|---|---|
| Length of one leaf | Up to 3 m for a new selection; assess longer gates individually |
| Weight of one leaf | Maximum 600 kg for a leaf up to 2.5 m long; above 2.5 m, follow the decreasing limit shown in the graph |
| Solid infill and wind | Can significantly increase the load. A 230 V supply alone does not confirm that the specific gate is suitable. |
The leaf must be rigid and correctly balanced, and should move by hand along its full travel with consistent resistance. The hinges must be aligned on a common axis with the box pin. For a leaf longer than 2.5 m an electric lock is recommended NICE PLA10 or NICE PLA11. Using two motors does not change the limit for a single leaf.
A speed of 1.14 rpm corresponds approximately to 13–14 seconds for 90° excluding acceleration and deceleration. The motor duty cycle is 30%; this is not continuous operation. For 90°, the rating is 30 cycles/hour; with the MEA1 accessory at 180°, it is half that, or 15 cycles/hour. The duty time and conditions for the complete setup must also be observed.
Installing the box and mounting the motor
The box pin must be aligned with the hinge axis. Install the box horizontally, at a height appropriate for the specific setup and surrounding surface. Provide a separate cable conduit and effective drainage. Detailed instructions for installing the foundation box.
- Prepare a pit to suit the box dimensions and local foundation conditions. The drainage must carry water away, not discharge into an impermeable pit.
- Before installation, attach the opening-stop accessory in the position shown in the diagram.
- Align the box pin with the hinge axis, prepare the conduit and drainage, and set the box in concrete in a level position.
- Fit the control bracket with the supplied ball onto the pin. Position the leaf against the release lever and secure it with a weld; lubricate the designated point through the grease nipple.
- Insert the motor in the correct orientation, fit the closing stop, and secure it with four locknuts and washers.
- Connect the motor to the leaf using the connecting arm. Check manual movement, stops, locking and release.
- Route the cable out of the box to a suitable junction box; only then make the electrical connections.
The motor has a metal housing and an IP67 rating for temporary immersion. Water and debris remaining in the box for a long time indicate a drainage fault, not a normal operating condition. Electrical connections must not be made inside the box.
Mechanical stops and opening angle
In the standard mechanical setup, the opening angle is up to 110°. The closing stop is supplied with the motor, and the opening stop with the box. These are not electrical limit switches and are not connected to the control unit's FCA/FCC inputs.
For a wider angle of up to 360°, use NICE MEA1 with a gear wheel and chain. This accessory is designed for leaves up to 2.5 m long. Suitable external stops and clear, safe travel space are required; set the exact angle according to the complete installation.
Motor cable and connection to MC800
The supplied cable is 2 m. Joining wires inside the foundation box is prohibited. Use a suitable junction box outside the foundation box, accessible for inspection and protected from water. Disconnect the power supply before carrying out any work.
| MFAB3000 wire colour | Function and connection |
|---|---|
| Black | Switched live for opening → OPEN on the relevant M1 or M2 motor |
| Brown | Switched live for closing → CLOSE on the relevant M1 or M2 motor |
| Blue | Motor common wire → COMMON on the relevant motor terminal block |
| Yellow-green | PE protective conductor → protective earth |
Connect the motor to the 230 V AC output, not to the 24 V accessory supply. The motor has no magnetic encoder, and the black wire is not ENC. The motor has a built-in 10 µF capacitor; do not add another one just because another model uses a different wiring arrangement.
For the MC800/MCA5R30, the motor cable is 4 × 1.5 mm², with a maximum length of 10 m between the control unit and motor. Determine the terminal order from the OPEN, COMMON and CLOSE markings on the specific board, not from the wire colour order in the cable. Complete motor connection to MC800.
MC800/MCA5R30 accessory wiring and polarity
| Terminals | Voltage, polarity and purpose |
|---|---|
| 3 and 4 | 3 = minus (−), 0 V; 4 = plus (+), common +24 V DC. Accessory output: max. 200 mA. |
| 5 OUT STB and 3 | 5 = positive (+), 3 = negative (−). 24 V DC, max. 4 W; the output is switched off in Standby. The power supply for relay photocells also depends on the Phototest/Standby mode. |
| 6 and 7 BLUEBUS | Two-wire power supply and communication for compatible devices, for example EPMB. No polarity (+/−). |
| FLASH | Switched 230 V AC mains voltage, max. 21 W, for example ELAC. No polarity (+/−); this is not a 12 V output ELDC. |
| 1 and 2 EL | 12 V AC, max. 15 VA for an electric lock. No polarity (+/−). |
| 4 and 13 SbS | Voltage-free NO contact for step-by-step control. The external module must not feed its own voltage into the input. |
| AUX 8–11 | Optional input function, depending on the settings. For relay photocells, select the appropriate mode; do not simply connect them to any AUX input. |
The diagram shows relay photocells without Phototest, with Standby disabled. For other modes, use the relevant relay photocell wiring. EPMB and relay-type EPM photocells are not electrically interchangeable.
EPM relay photocells at 24 V DC
On both the transmitter and receiver EPM is terminal 1 positive (+), terminal 2 negative (−). On the RX 4 is the common COM contact and 5 is the NC contact; terminal 3 is NO. In the specified mode without Phototest, they are powered from terminals 4 (+) and 3 (−) on the control unit. Connect the RX contact between common terminal 4 and the selected, correctly programmed AUX input. The COM/NC contact pair is voltage-free and has no power-supply polarity.
Initial start-up and gate checks
Before switching on, the gate must move freely by hand through its full travel, the box must be drained, the stops must be set, and the drive must be engaged. Check the protective earth conductor, cable routing, photocells and protection of hazardous areas.
- Disconnect the mains and any battery, then check all connections; there must be no electrical joints in the box.
- Restore the power supply. On the specified current control unit, the BlueBUS LED should flash regularly once per second, the TX/RX photocell LEDs should flash, and the FLASH beacon should remain off. If the status is incorrect, disconnect the power and fix the cause.
- Run the connected-device recognition procedure, then teach the leaf positions on the actual control board installed.
- Check the direction of movement, both end positions, deceleration and the correct sequence of overlapping leaves.
- Test each safety device in its operating position and measure the forces across the entire gate.
- Hand over the working manual release, keys, instructions and inspection schedule. Use the gate only after the complete system has passed testing.
The MFAB3000 uses mechanical stops, not electric limit switches. The AUX setting on the MC800 must match the connected accessory; a mechanical stop is not connected as an FCA/FCC contact. Selecting the AUX input function.
Connected-device recognition
On the specified current control unit, press and hold OPEN ▲ and STOP/SET together for approximately 3 seconds. Release them when L1 and L2 start flashing rapidly. Wait for completion: the STOP LED will stay lit and L1/L2 will go out. Run the learning procedure even when no devices are connected, and repeat it after adding or removing devices.
Automatic position learning
On the MC800/MCA5R30, first check that the motor force is appropriate – parameter L6. Then press and hold CLOSE ▼ and STOP/SET for approximately 3 seconds; release them when L3/L4 flash rapidly. For a double-leaf gate, the sequence is: close M1, close M2, open M2, open M1, close M1 and close M2. When the procedure is complete, L3/L4 will go out.
If the first movement is in the wrong direction, stop the learning procedure immediately by pressing OPEN or CLOSE. Correct the wiring only after disconnecting the power, then repeat the learning procedure. If a photocell or STOP device is triggered, learning will be interrupted and L1 will start flashing; fix the cause and start again. Older boards may use a different procedure.
Control unit settings, remotes and servicing
| What you need to set | Procedure for the relevant control unit |
|---|---|
| Device recognition | Device recognition |
| Travel learning | Travel learning |
| Relay photocells and AUX | Relay photocells and AUX |
| Automatic closing and pause | Automatic closing and pause |
| Motor force | Motor force |
| Pairing remotes | Pairing remotes |
| Control unit diagnostics | Control unit diagnostics |
Do not compensate for binding hinges or a flooded box by increasing the force setting. After changing positions, stops or force settings, check safety again. Deleting remotes and resetting the board are different procedures; follow the instructions for the control unit actually installed.
If the drive is not working properly
| Symptom | What to check |
|---|---|
| The leaf is difficult to move even when disengaged | Hinges, box alignment, deformation and stops. First fix the mechanical cause; installation. |
| Water is standing in the box | Disconnect the power supply. Clean and check the drainage; maintenance. Have damaged electrical components checked before using the system again. |
| The motor does not start or stops | Check the power supply and fuses on the control unit, the status of STOP and the photocells, and the error indicators. Do not bypass safety devices; Diagnostics. |
| The motor runs, but the gate leaf does not move | Engage the manual release and check that the motor is mechanically connected to the gate leaf. Release and return to operation. |
| The gate leaf moves in the wrong direction | Disconnect the power supply, check the motor wires, and run the learning procedure again; motor wiring. |
| Only the radio remote control is failing | Check the transmitter battery, coding compatibility, antenna, and whether the button is stored in the correct receiver. |
Maintenance and safe use
Carry out an inspection at least every six months, or more often in demanding conditions, in accordance with the maintenance schedule. Before carrying out any work, disconnect the mains supply and backup power source, and secure the gate leaf to prevent movement.
- Clean the box and drainage; water and dirt must not obstruct the mechanism.
- Check that the motor, gate leaf, and stops are securely fastened, and inspect the cables and manual release.
- Check lubrication of the mechanical contact points in accordance with the installation procedure.
- Repeat the manual travel test and test the photocells and other safety devices.
- Measure the forces and carry out any necessary repairs; do not use a damaged assembly.
The gate must remain under supervision while moving. Keep controls out of children's reach, stay clear of the travel path, and use the safe manual release in the event of a fault. If the gate leaf has a pedestrian gate, opening it must disable the drive.
Manual release and return to operation
In the event of a power failure, the gate can be moved manually using the selected mechanism NICE MEA2 or NICE MEA3. First switch off the power supply and secure the gate leaf to prevent it from moving on its own.
| Mechanism | Release |
|---|---|
| MEA2 – key | Flip open the lock cover, insert the key, and turn it 90° clockwise. Move the gate leaf by hand. To re-engage the lock, turn the key 90° in the opposite direction. |
| MEA3 – lever | Insert the lever into the release mechanism and turn it in the direction shown in the illustration. Operate the gate leaf manually, then return the mechanism to the locked position. |
After re-engaging the lock, check that the drive is connected to the gate leaf and that it moves safely. If the release mechanism does not operate easily, do not force it; check the assembly.
Technical specifications and dimensions
| Parameter | MFAB3000 |
|---|---|
| Motor power supply | 230 V AC / 50 Hz |
| Current consumption and power | 1.2 A / 250 W |
| Torque | 300 Nm |
| Speed | 1.14 rpm |
| Built-in capacitor | 10 µF |
| Duty cycle | 30% |
| Cycles per hour | 30 at 90°; at 180° with MEA1, half that number |
| Thermal protection | 140 °C |
| Ingress protection rating and operating temperature | IP67; −20 to +50 °C |
| Motor weight | 11 kg; the weight of the box and release mechanism is assessed separately |
| Overall dimensions of the assembly | 390 × 322 × 194.5 mm; exact installation depends on the selected box |
| Power cable | 2 m |
| Standard opening angle / optional accessory | Up to 110° / NICE MEA1 up to 360°, for gate leaves up to 2.5 m |
Product view