NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg

NEW


Product availability: within 14 days

We normally dispatch goods within 14 days.


NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg
NICE-LFAB4024HS
within 14 days
€391.26 excluding VAT
€481.25 including VAT

 pcs
Weight
15 kg

Description of NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg

NICE L-FAB LFAB4024HS is a standalone underground non-reversible operator for one gate leaf. It has a 24 V DC motor with a magnetic encoder. The control unit is not included; for a new setup, use NICE MC824HR30. A double-leaf gate requires two operators and one compatible control unit.

The operator is concealed beneath the hinge axis and does not affect the gate’s appearance from either side. An underground solution is also suitable where there is no room for a linear operator or articulated-arm operator. The box with its supporting lever forms the lower pivot for the gate leaf; it must be securely installed, aligned with the hinges, and drained.

The HighSpeed version opens to 90° in approximately 6 seconds under standard installation conditions, excluding acceleration and deceleration. The actual time depends on the gate leaf and the speed setting. Limit: 4 m / 400 kg does not mean 400 kg at a length of 4 m.

24 V is the motor voltage; the MC824HR30 has a 230 V AC mains supply. For a complete setup, also select a box, release mechanism, controls, and safety devices.

Quick navigation
Controls and accessoriesMotor and box
Choosing an operatorKits
InstallationStops
Motor wiringAccessory terminals
Initial start-upSettings and controls
Manual releaseTroubleshooting
MaintenanceService life
Specifications and dimensionsPDF manual

Controls and compatible accessories

The wiring and programming instructions below apply to the MC824HR30 with an MCA1R30 board. For an older control unit, choose the wiring diagram for the board actually installed. The MC824L is not a replacement for the MC824H with this operator.

What Why Type
Control unit

Controls one or two operators. Motor wiring.

  • Current MC824HR30 with an MCA1R30 board.
  • Older configuration: MC824HR10 and MCA1R10. Choose the wiring diagram according to the board actually installed.
Flashing light

Indicates gate movement. The voltage and maximum current draw must match the FLASH output.

  • LED flashing light with antenna ELDC
  • Multifunctional light WLT

Other flashing lights should be selected according to the voltage and current draw of the control unit’s FLASH output.

Photocells

Protection across the gate opening, depending on the photocell placement and operating mode; wiring.

  • Wired BlueBUS – EPMB, EPLB, EPSB
  • BlueBUS with reflector – EPMORB
  • Wireless with IBW interface – EPMOW
  • Wired BlueBUS, adjustable – F210B
  • BlueBUS with battery-powered transmitter – FT210B
  • Wired BlueBUS – EPMOB

EPMOW requires the radio interface IBW connected to BlueBUS. FT210B has a battery-powered transmitter on the gate leaf and a receiver connected to BlueBUS by two wires; it also transmits the status of the safety edge.

Transmitter

Remote control compatible with the coding of the installed receiver. ON3ELR uses OXILR; ON3EBD uses OXIBD. Pairing the remote control.

Receiver

Radio receiver for the control unit’s SM connector. The receiver and transmitter must use the same coding. OXILR and OXIBD use different radio systems.

  • GSM modules trigger the command via a volt-free NO contact; select the power supply according to the specific module.
Antenna

Choose an antenna to match the frequency of the installed receiver. With OXIBD, connect it to the antenna terminals.

  • Integrated into the flashing light ELDC
  • External antenna ABFKIT
Keypad

Access using a code. Choose EDSWG to match the receiver; EDSB uses BlueBUS and device learning.

Key switch

Key-operated control via a volt-free NO contact connected to the control unit’s command input.

  • Surface-mounted, standard cylinder EKS
  • Surface-mounted, Euro cylinder EKSEU
  • Flush-mounted, standard cylinder EKSI
  • Flush-mounted, Euro cylinder EKSIEU
Electric locks

An electric lock is required with the LFAB4024HS for gate leaves longer than 3 m. ELS power supply.

Card readers

Access using a chip or card. Connect ETPB to BlueBUS; run device learning after connecting it.

  • ERA Transponder Reader ETPB
Backup power supply

Operation during a mains power failure. Choose a battery compatible with the control unit’s board and connector.

  • Older backup battery PS324

For the current MC824HR30 PSS324. The older PS324 requires CABLA11 and Standby switched off (L4 = OFF); backup wiring.

Safety edgeLimits the consequences of contact with an obstacle; hazardous areas require separate protection. Tests before handover.
  • An edge with an 8.2 kΩ output connected to STOP, or a suitable assembly with FT210B. STOP wiring.

Motor, foundation box and release mechanism

Assembly componentWhat you need
Standalone LFAB4024HSOne motor with a magnetic encoder, a 2 m power cable and a mechanical closing stop. Neither the box nor the control unit is built into the motor.
Foundation boxLFABBOX4 made of cataphoretically treated steel or stainless steel LFABBOX4I. The box includes a load-bearing gate-leaf lever and a mechanical opening stop. Sold separately.
Manual releaseNICE BMA3 with a lever key for manually moving the gate leaf during a power failure. Sold separately.
Controls and safetyMC824HR30, receiver, remote controls, photocells and a safety edge, depending on the specific gate.
Wider opening angleNICE BMA1 with chain drive, up to 360° for gate leaves up to 3.5 m. Suitable clearance and external mechanical stops are required.

The motor has a metal housing. The box can be used with either right- or left-hand gate leaves. The steel and stainless-steel versions differ in material and surface finish; even a stainless-steel box does not replace effective water drainage.

Kits for one or two gate leaves

The kits differ in the number of motors, boxes and release mechanisms. Two motors do not increase the permitted length or weight of an individual gate leaf. Compare the equipment below for the complete gate.

One gate leafStandalone motorTwo gate leaves

Kit for one gate leaf

NICE L-Fab LFAB4024HS drive kit for a single-leaf gate up to 4m/400kg

1 × LFAB4024HS, 1 × LFABBOX4, 1 × NICE BMA3.

1 × MC824HR30, 1 × OXIBD, 1 × MYGO4, 1 pair EPMB, 1 × ELDC.

Standalone LFAB4024HS

NICE L-Fab LFAB4024HS – standalone underground drive for a swing gate with leaves up to 4m/400kg

One 24 V DC motor with encoder. The box, release mechanism and control unit are sold separately.

Kit for two gate leaves

NICE L-Fab LFAB4024HS drive kit for a double-leaf gate – each leaf 4m/400kg

2 × LFAB4024HS, 2 × LFABBOX4, 2 × NICE BMA3.

1 × MC824HR30, 1 × OXIBD, 1 × MYGO4, 1 pair EPMB, 1 × ELDC.

Gate length, weight and operation

4 m and 400 kg are separate maximum limits. Read the permitted weight for the given length from the graph: the horizontal axis shows the length of one gate leaf in metres, and the vertical axis shows its weight in kilograms. For a 4 m gate leaf, the limit is approximately 150 kg; for a shorter leaf, select the weight according to the curve.

NICE LFAB4024HS – permitted weight by length of one gate leaf

Gate-leaf height, solid infill, strong winds and hinge resistance can substantially reduce the permitted values. Before choosing, check the gate's full manual travel and safe operating forces; weight or motor power alone does not guarantee suitability.

FeatureLFAB4024HS
ApplicationFast operation of a lighter gate leaf
Maximum limits according to the graph4 m / 400 kg
Maximum torque200 Nm
Operation with the gate open to 90°50 cycles/h
BoxLFABBOX4 / LFABBOX4I
Control unit for the new assemblyMC824HR30

One cycle consists of opening and closing. When opening to 180° with BMA1, the stated number of cycles per hour is halved. This is operation at the rated load, not unlimited continuous operation.

Installing the box and drive

The gate must be mechanically sound: the leaf must move easily by hand, without catching or moving on its own. Also check for pinch points at the hinges and between the leaves. If the leaf has a pedestrian gate, it must have a monitoring contact that disables the drive when the gate is open.

Drainage, alignment and concreting

  1. Prepare an excavation for the specific box, its secure concrete bedding, cable conduits and drainage. Check the dimensions and installation height against the supplied box before concreting.
  2. Provide a separate cable route and effective drainage to the box. The drain must not be blocked or routed to a place where water can flow back.
  3. Position the box level. The axis of its pin must align precisely with the axis of the leaf hinges throughout the full travel. Check the position and installation height before concreting.
  4. Securely concrete the box in place and allow the concrete to cure fully. Protect the threads and drain from contamination.

LFAB4024HS – separate water drainage and cable routing from the foundation box

LFAB4024HS – align the box pin axis with the leaf hinges

LFAB4024HS – level and concrete the foundation box in place

For practical instructions, see the foundation box installation guide. Ingress protection rating IP67 protects the motor even during temporary immersion; it does not replace drainage and is no reason to leave the box flooded for long periods.

Fitting the motor and attaching the leaf

  1. Place the motor in the box in the correct orientation and secure it with washers and nuts.
  2. Fit the ball and operating bracket onto the box pin. Install the release and connecting arms as shown in the drawing. All moving parts must be connected correctly.
  3. Attach the leaf to the support arm with bolts or a secure weld. Tighten the illustrated bolted connection to 30 Nm. When welding, protect the motor, release mechanism and plastic parts from heat; do not weld the leaf to the release sleeve marked as an incorrect location.
  4. Lubricate the specified contact surfaces and check that movement is unobstructed. Route the cable without strain or damage; there must be no cable joint inside the box.
  5. After setting the stops and completing the tests, fit the cover and secure it with two screws. Keep access to the release mechanism clear.

LFAB4024HS – securing the motor in the foundation box

LFAB4024HS – connecting the support arm, connecting arm and box pin

Arm legend: 1 release arm, 2 connecting arm, 3 ball, 4 operating bracket, 5 box pin. The numbers in the following attachment procedure indicate the installation order.

LFAB4024HS – bolted leaf attachment, 30 Nm, or a suitable weld

Mechanical stops and opening angle

The standard opening angle is up to 110°. If the gate does not have suitable external stops, install the supplied stops: 1 is the closing stop on the motor; 2 is the opening stop in the box. They stop the leaf in the required position without it hitting the surrounding structure. These are mechanical stops, not electrical limit switches.

LFAB4024HS – 1 closing stop on the motor, 2 opening stop in the box

A greater opening angle is possible with NICE BMA1 with chain drive, up to a maximum of 360°, and only for leaves up to 3.5 m. Suitable external stops and a safe clear area are also required for this installation. The BMA1 limit does not replace the drive load chart.

Manual release in the event of a power failure

Stop the gate and disconnect the mains supply and any backup battery. Hold the leaf, especially in windy conditions. Keep people clear of its path.

  1. Slide open the release access cover.
  2. Insert the supplied BMA3 lever key and turn it 90° clockwise.
  3. Now move the leaf by hand, slowly and without force.

LFAB4024HS – manual release using the BMA3 lever key

Re-engaging the drive

  1. Move the leaf to approximately the halfway point of its travel.
  2. Slide open the cover, insert the key and turn it 90° counterclockwise.
  3. Move the leaf gently until the mechanism audibly engages. Make sure the mechanism is properly locked before restoring power.

LFAB4024HS – re-engaging the drive mechanism after manual release

Connecting the motor and control unit

Disconnect the mains supply and backup battery before carrying out any work. Do not place any cable joints or terminal blocks in the foundation box. Use a suitable protected junction box outside the box for any cable extensions. Maintain the protective earth connection (PE).

LFAB4024HS wiresConnection
Blue and brownMotor 24 V DC power pair, connected to output M1 or M2. The control unit changes the direction of movement by reversing the power supply; do not assign fixed +/− polarity to this pair.
Black and greyEncoder pair, connected to ENC1 or ENC2 for the same motor. Encoder wires are not polarity-sensitive.
Yellow-greenProtective earth (PE). Do not use it for the motor or encoder signal.

With the MC824HR30, connect one motor to M2 and ENC2. With two motors, M2 is for the leaf that opens first; M1 is for the leaf that closes first. The ENC connection must correspond to the output for the same motor. If the supplied cable is labelled differently, check the wiring for the specific motor before connecting it.

Wiring for the MC824HR30Cross-section and length
Motor, including PE3 × 1.5 mm², maximum 10 m.
Encoder2 × 1 mm², maximum 10 m.
BlueBUS2 × 0.5 mm² up to 20 m; for lengths over 20 m and up to 40 m, 2 × 1 mm².
FLASH2 × 0.5 mm², maximum 20 m.
AntennaShielded RG58; under 5 m recommended, maximum 20 m.

Use cables suitable for the environment and route them in protective conduit. The motor and encoder can be connected using a single suitable 5 × 1.5 mm² cable. Other wiring and mains power supply: MC824HR30 wiring.

MC824HR30 – original connection of motors, encoders and accessories

Accessory terminals and polarity

MC824HR30 output or inputPower supply and polarity
Auxiliary power supplyLeft SbS terminal = +; right STOP terminal = − when viewing the board as shown in the image below. 24 V DC −30/+50%, maximum 200 mA for all connected devices combined.
BLUEBUSTwo wires non-polarized. They carry both power and data; they are not general-purpose +/− terminals.
FLASHFlashing-light output 12 V DC, maximum 21 W; e.g. ELDC. Follow the wiring diagram for the specific light; do not confuse the +/− polarity of this output with the SbS/STOP auxiliary power supply.
OGIGate-open indicator, 24 V DC, maximum 4 W. For polarity-sensitive lights, follow the markings on the actual output and light.
ELSElectric lock 12 V AC, maximum 15 VA; AC supply, no +/− polarity.
SbS, OPEN, CLOSEControl inputs for a voltage-free NO contact. Do not apply external voltage to these inputs.
STOPVoltage-free NO/NC contacts or an 8.2 kΩ resistive safety edge, depending on the selected configuration. The input is detected during device learning; do not apply external voltage to it.

MC824HR30 – auxiliary power supply: left SbS terminal positive, right STOP terminal negative

BlueBUS devices are connected in parallel. Each pair of photocells must have the correct address for the required response; repeat device learning after making any changes. MC824HR30 photocell wiring and addressing. Relay photocells must not be connected directly to BlueBUS. The 230 V ELAC flashing light must not be connected to this 12 V DC FLASH output.

Initial startup and safety tests

The system requires a suitable safety-sensitive edge to limit impact forces. Its type and position must be determined according to the hazardous areas of the gate. Photocells and force settings alone do not replace a complete safety test.

  1. Disengage the drive and manually check the full travel path, alignment, secure mounting, both end stops and drainage. The gate leaf must not catch or move on its own.
  2. Re-engage the release mechanism. Check the motor, encoder, PE, safety devices and accessories.
  3. With the power disconnected, set the correct motor type using the 12-position selector. Then switch on the power and check the input status.
  4. Run device and travel-limit learning. Watch the direction and sequence of the leaves; stop immediately if movement is incorrect or unexpected. Disconnect both the mains supply and backup power before repairing the wiring.
  5. Test the full cycle, slowdowns, end stops and release mechanism. Test each pair of photocells, the safety edge and any emergency stop separately.
  6. Have the effective forces measured by a qualified professional before handover. Attach the manual release instructions to the drive and explain operation, release and maintenance to the user. Do not use the gate until all tests have been completed.

MC824HR30: selecting the LFAB4024HS motor

Set the 12-position selector to DIP 8 = ON; all other DIP switches 1–12 = OFF. Make the setting with the power disconnected, before learning the travel limits. After changing the motor selection, the travel limits must be learned again.

MC824HR30 – LFAB4024HS, DIP 8 ON and all others OFF

LFAB4024HS belongs to the WINGOELITE group on the selector. Use only the selector setting specified for LFAB4024HS.

MC824HR30: device learning

Press and hold simultaneously Open and Stop/Set. When L1 and L2 start flashing rapidly, after approximately 3 seconds, release the buttons. When complete, STOP must be lit and L1 and L2 must be off; L3 and L4 may flash if the travel limits have not yet been learned. Repeat learning after changing BlueBUS or STOP devices.

MC824HR30: automatic travel-limit learning

Before learning, check the wiring, correct motor selection, operation of the safety devices and the mechanical end stops. Device learning must be completed first. For a single motor, connect it to M2/ENC2. Keep the movement in view while it is running.

  1. Press and hold simultaneously Stop/Set and Close. When L3 and L4 start flashing rapidly, after approximately 5 seconds, release both buttons.
  2. For a double-leaf gate, M1 first closes slowly to the mechanical end stop, followed by M2. M2 and M1 then open slowly to their end stops, followed by both leaves closing quickly.
  3. When learning is successful, L3 and L4 go off. Check the complete cycle and the safety devices.

If the direction or sequence is incorrect, stop learning immediately by pressing Open or Close. Disconnect both the mains supply and backup power before checking the wiring. If swapping M1/M2, also swap the corresponding ENC1/ENC2 pairs; if the direction is reversed, check the motor power pair. Then repeat the learning procedure.

If learning is interrupted by a photocell or the STOP input, L1 flashes. Resolve the cause and restart automatic learning; do not bypass the safety devices. Detailed procedure and additional MC824HR30 learning modes.

Settings, controls and reset

The control unit sets the force, speed, automatic-closing pause, partial opening and leaf sequence. After making changes, check the safety forces and protective devices. Increasing the force is not a solution to poor mechanical installation.

Deleting radio remote controls and resetting the control unit are separate procedures. After settings are erased, the relevant learning procedure must be repeated. Follow the procedure for the specific control board and receiver.

Troubleshooting

SymptomWhat to check
The gate leaf cannot be moved manuallyManual release, hinges, linkage between the arms, alignment and foreign objects in the box. Do not force a jammed gate to operate.
Motor runs, gate leaf does not moveManual release mechanism engagement and linkage between the arms. Disconnect the power supply before carrying out any work.
Incorrect direction or sequenceM1/ENC1 and M2/ENC2 assignment, motor selection and teach-in again.
Gate stops or reversesFree movement, obstructions, photocells, safety edge and Control unit LED indications. Once the cause has been removed, carry out safety tests.
Water in the boxDrain, debris, water backing up and wiring. If a cable is damaged or water has entered a connection, take the equipment out of service.
Remote control does not respondCheck the remote control battery, its pairing, the receiver and the antenna; remote control pairing.

Maintenance

Have the equipment professionally maintained at least every 6 months, and more often with intensive use or in harsh environments. Disconnect the mains power and backup supply before cleaning or servicing. Do not use a damaged or binding gate until it has been repaired.

  • Remove mud, leaves and stones from the box, and keep the drain clear.
  • Check for corrosion and inspect the cables, screws, hinges, arms and stops; replace worn parts.
  • Lubricate the designated moving contact surfaces through the grease nipple with a suitable lubricant. Check that the gate moves freely and that the manual release works.
  • After maintenance, test manual operation, a complete automatic cycle and every safety device.

LFAB4024HS – lubricating the moving mounting point through the grease nipple

Estimated service life

Service life depends on the weight and length of the gate leaf, as well as the environment. Add the index for the relevant combination and any other applicable factors. First, the operating limitsmust be met; the service-life index does not authorize using a heavier gate leaf. The graph shows the estimated number of cycles with regular maintenance, not a guarantee or a number of years. The horizontal axis shows the sum of the indices as a percentage; the vertical axis shows the number of cycles.

Add 15% for temperatures above 40 °C or below 0 °C, or humidity above 80%. A solid infill adds 20%; a windy environment adds a further 15%.

Properties of the complete automation systemIndexService-life graph
Up to 150 kg2.01–3 m: 10%
3.01–4 m: 20%
Estimated number of cycles by total service-life index
151–350 kg2.01–3 m: 20%
3.01–4 m: 30%
351–400 kg2.01–3 m: 30%
3.01–4 m: 40%
Temperature / humidity+15%
Solid infill+20%
Windy environment+15%

Example: a 3 m / 180 kg gate leaf has an index of 20%. In a windy environment, add 15%, for a total of 35%. Add any other applicable factors as well.

The combinations shown apply to gate leaves longer than 2 m. For a shorter gate leaf or an unclear combination, contact us with the length, weight, infill type and required number of cycles.

Technical specifications and dimensions

ParameterNICE LFAB4024HS
Motor voltage24 V DC, separate from the control unit's mains power supply
Control unit for the new assemblyMC824HR30 / MCA1R30, 230 V AC mains
EncoderMagnetic, separate ENC connection
Peak current / power consumption7 A / 170 W
TorqueMaximum 200 Nm; rated 90 Nm
SpeedNo load: 3 rpm; at rated torque: 2.4 rpm
90° openingApproximately 6 s, excluding acceleration and deceleration, with standard installation.
Operation at 90° opening50 cycles/h at rated load; half that at 180° with BMA1
Standard opening angleUp to 110°; with BMA1, up to 360° for a gate leaf up to 3.5 m
Protection rating / operating temperatureIP67 / −20 to +55 °C
Power cable2 m; extensions and connections must be outside the box
Motor weight12.5 kg; box weight is calculated separately
Steel boxLFABBOX4 – 14.4 kg
Box dimensions as shown in the drawing400 × 325 mm, body height 152 mm; also observe the position of the pin and the hinge axis

Maximum torque and peak power consumption are not continuous-duty ratings. When planning the excavation and gate-leaf height, refer to the drawing and the box actually supplied. The dimensions of the motor alone are not a substitute for the box dimensions.

NICE LFABBOX4 – box dimensions and supporting pin position

Product view

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg

Product: NICE L-Fab LFAB4024HS – standalone underground operator for a swing gate leaf up to 4 m/400 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.