NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4 m/650 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4 m/650 kg NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4 m/650 kg
NICE-LFAB4024
within 3 days
€349.95 excluding VAT
€430.44 including VAT

 pcs
Weight
15 kg

Description of NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4 m/650 kg

NICE L-FAB LFAB4024 is a standalone underground non-reversible drive for one gate leaf. The motor has 24 V DC and a magnetic encoder. It does not include a control unit; for a new setup, use NICE MC824HR30. For a double-leaf gate, you need two motors and one compatible control unit.

The motor is concealed beneath the hinge axis and does not detract from the gate's appearance. An underground solution is also suitable where there is no room for a linear drive or articulated-arm drive. The foundation box and leaf fixing form the bottom support for the gate leaf. Secure installation, hinge alignment and effective water drainage are essential.

24 V is the motor voltage; the MC824HR30 is powered by 230 V AC mains. The LFAB4024 is suitable for more frequent use and supports a compatible backup battery. Motor voltage alone does not determine safety or suitability for a particular gate.

Quick navigation
Controls and accessoriesMotor and box
Choosing a driveKits
InstallationStops
Motor wiringAccessory terminals
Initial startupSettings and controls
Manual releaseTroubleshooting
MaintenanceService life
Specifications and dimensionsPDF manual

Control units and compatible accessories

Choose the equipment to match the installed control unit. For an older control board, follow its own wiring diagram and settings; a newer diagram is not a universal guide for all generations.

What Why Type
Control unit

Controls one or two motors. Motor wiring.

  • Current model: MC824HR30 with an MCA1R30 board.
  • Older version: MC824HR10 and MCA1R10. Choose the wiring instructions to match the board actually installed.
Warning light

Indicates gate movement. The voltage and maximum current draw must match the FLASH output.

  • LED warning light with antenna ELDC
  • Multifunction light WLT

Other warning lights should be selected to match the voltage and current draw of the specific control unit's FLASH output.

Photocells

Passage protection depends on the photocell placement and operating mode; wiring.

  • Wired BlueBus – EPMB, EPLB, EPSB
  • BlueBus with reflector – EPMORB
  • Wireless with IBW interface – EPMOW
  • Adjustable wired BlueBus – F210B
  • BlueBUS with battery-powered transmitter – FT210B
  • Wired BlueBus – EPMOB

EPMOW requires a radio interface IBW connected to BlueBUS. FT210B has a battery-powered transmitter on the gate leaf and a receiver connected to BlueBUS by two wires; it also transmits the safety edge status.

Safety edgeA safety edge is required to limit impact forces. The positioning and function of the protective devices must be checked across the entire gate.
Transmitter

Remote control compatible with the coding of the installed receiver. ON3ELR uses OXILR; ON3EBD uses OXIBD. Pairing the remote control.

Receiver

Plug-in radio receiver for the control unit's SM connector. The receiver and transmitter must use the same coding. OXILR and OXIBD use different radio systems.

  • GSM modules trigger the command via a volt-free NO contact; select the power supply according to the specific module.
Antenna

Improves remote-control reception. With OXIBD, connect the antenna to its antenna terminals.

  • Integrated into the warning light ELDC
  • External antenna ABFKIT
Keypad

Access using a code. Choose EDSWG according to the receiver; EDSB uses BlueBUS and device learning.

Key switch

Key-operated control via a volt-free NO contact connected to the control unit's command input.

  • Surface-mounted, standard cylinder EKS
  • Surface-mounted, European cylinder EKSEU
  • Recessed, standard cylinder EKSI
  • Recessed, European cylinder EKSIEU
Electric locks

Additional gate leaf locking. The control unit releases the lock before opening. Selection depends on the length, rigidity and load of the gate leaf; lock output.

Card readers

Access using a chip or card. Connect ETPB to BlueBUS; run device learning after connection.

  • ERA Transponder Reader ETPB
Backup power supply

Operation during a power outage. Choose a battery compatible with the control board and control unit connector.

  • Older backup battery PS324

For the current MC824HR30 PSS324. The older PS324 requires CABLA11 and Standby switched off (L4 = OFF); backup connection.

Motor, foundation box and manual release

Assembly componentWhat you need
Standalone LFAB4024One motor, a 2 m power cable and a mechanical closing stop. The magnetic encoder detects motor movement.
Foundation boxLFABBOX4 made of cataphoresis-treated steel or stainless steel LFABBOX4I. They use the same mounting method; the box includes a gate-leaf lever and a mechanical opening stop. Sold separately.
Manual releaseNICE BMA3 with a lever key, required to move the gate leaf manually during a power failure. Sold separately.
Control and safetyNICE MC824HR30, receiver, remote controls, photocells and safety equipment according to the specific gate. Not built into the standalone motor.
Wider opening angleNICE BMA1 with chain drive, up to 360° for gate leaves up to 3.5 m. Requires suitable clearance and external mechanical stops.

The motor and box can be used with either right- or left-hand gate leaves. LFABBOX4 and LFABBOX4I differ in material and surface finish; even a stainless-steel box does not replace drainage. When replacing, check the actual box, levers and manual release.

Kits for one or two gate leaves

The number of motors corresponds to the number of gate leaves. Two motors do not increase the permitted length or weight of an individual gate leaf. When comparing kits, check the boxes, manual release, control unit and safety equipment.

One gate leafStandalone motorTwo gate leaves

Kit for one gate leaf

NICE L-Fab LFAB4024 operator kit for a single-leaf gate up to 4m/650kg

1 motor, 1 LFABBOX4 box and 1 BMA3 manual release.

MC824HR30, OXIBD, MYGO4, 1 pair of EPMB photocells and ELDC.

Standalone LFAB4024

NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4m/650kg

One 24 V DC motor with encoder. The box, manual release and control unit are selected separately.

Kit for two gate leaves

NICE L-Fab LFAB4024 operator kit for a double-leaf gate – each leaf up to 4m/650kg

2 motors, 2 LFABBOX4 boxes and 2 BMA3 manual releases.

MC824HR30, OXIBD, MYGO4, 1 pair of EPMB photocells and ELDC.

Gate length, weight and operation

4 m and 650 kg are separate maximum limits; they do not apply simultaneously. Read the permitted weight for the given length from the graph: the horizontal axis shows gate-leaf length in metres, and the vertical axis shows its weight in kilograms. For a gate leaf around 3 m long, the limit is approximately 500 kg; at 3.5 m, approximately 400 kg. At 4 m, the permitted weight is lower still. These values do not replace an assessment of resistance to movement, infill and wind load.

NICE L-FAB – graph of permitted weight by length of one gate leaf

FeatureLFAB4024
Motor voltage24 V DC
Control unit for the new assemblyMC824HR30
Cycles/hour at rated loadMaximum 60 cycles/hour
Magnetic encoderYes
Battery backupMC824HR30 compatible backup

One cycle consists of opening and closing. When opening to 180° with BMA1, the stated number of cycles per hour is halved. This is not designed for unlimited continuous operation. Smooth manual movement and correct mechanical installation must be maintained throughout the full travel.

Installing the box and operator

Install on a sturdy gate that operates smoothly. The gate leaf must move easily by hand, without sticking or moving by itself. The operator will not fix faulty hinges or an unstable installation. Also check for crushing hazards at the hinges and between the gate leaves; a pedestrian gate built into a leaf must have protection to prevent operation while it is open.

Drainage and cabling

  1. Prepare an excavation large enough for the specific box, with a solid concrete foundation, water drainage and cable conduits. Check the dimensions against the actual box supplied before pouring concrete.
  2. Provide a separate cable route and effective drainage to the box. The drain must not be blocked or routed to a place where water can flow back into the box.
  3. Position the box level. The box pivot axis must align exactly with the gate-leaf hinge axis throughout its full travel. Check the position and mounting height before pouring concrete.
  4. Secure the box firmly in concrete and allow the concrete to cure sufficiently before installing the operator. Protect the drain and threads from dirt during the work.

L-FAB – separate water drainage and cable routing from the foundation box

L-FAB – foundation box axis aligned with the gate-leaf hinges

L-FAB – levelling and concreting the foundation box

For further practical guidance, see the foundation box installation guide. Ingress protection rating IP67 describes the motor's protection; it is not a reason to leave the box flooded for long periods.

Installing the motor and attaching the gate leaf

  1. Place the motor in the box in the correct orientation and secure it with washers and nuts at the prepared mounting points.
  2. Install the ball, control bracket, release lever and connecting lever according to the original drawing. The parts must move freely and be connected correctly.
  3. Secure the gate leaf to the load-bearing arm with screws or a suitable permanent weld. For the indicated screw fixing, the tightening torque is 30 Nm. When welding, protect the motor, plastic parts and release mechanism from heat.
  4. Lubricate the moving contact surfaces and check that they move freely. Route the power cable without tension or damage; the cable joint must not be inside the box.
  5. After adjusting the stops and carrying out the tests, fit the box cover and secure it with screws. Keep the release mechanism accessible.

L-FAB – securing the motor in the foundation box

L-FAB – 1 release lever, 2 connecting arm, 3 ball, 4 bracket, 5 box pin

L-FAB – securing the gate leaf with screws tightened to 30 Nm or with a suitable weld

Mechanical stops and opening angle

The usual opening angle is up to 110°. If the gate does not have suitable external stops, set the supplied: stop 1 on the motor for closing and stop 2 in the box for opening. The stops must bring the gate leaf to a halt in the required position without it striking the surrounding structure. These are mechanical stops, not electrical limit switches.

L-FAB – 1 closing stop on the motor, 2 opening stop in the box

For a wider opening angle, use NICE BMA1 with a chain drive. This accessory is limited to gate leaves up to 3.5 m; suitable external stops and safe clearance are also required for this installation.

Manual release in the event of a power failure

Before releasing the gate, stop it and disconnect the power supply and any backup battery. Hold the gate leaf, especially in windy conditions or on a slope. Keep people clear of its path.

  1. Slide open the cover over the release access.
  2. Insert the supplied BMA3 lever key and turn it 90° clockwise.
  3. You can now move the gate leaf by hand, slowly and without forcing it.

L-FAB – manual release procedure using the lever key

Re-engaging the drive

  1. Move the gate leaf to approximately the midpoint of its travel.
  2. Slide open the cover, insert the key and turn it 90° anticlockwise.
  3. Gently move the gate leaf until the mechanism re-engages with a clear click. Check that it is properly locked before restoring the power supply.

L-FAB – re-engaging the drive after manual release

Connecting the motor and control unit

Disconnect the mains and backup power before carrying out any work. The mains supply must allow complete safe disconnection, and the motor and assembly must be properly earthed. Do not place any cable joint or terminal block inside the foundation box. Make the connection in a suitable protected junction box outside the foundation box.

LFAB4024 wiringConnection
Blue and brownThe 24 V DC motor pair connects to the corresponding M1 or M2 output. Check the direction during the initial start-up.
Black and greyConnect the magnetic encoder pair to ENC1 or ENC2 for the same motor. The encoder wires are not polarity-sensitive.
Yellow-greenProtective earth (PE); never use it for the motor or encoder signal.

With the MC824HR30, connect one motor to M2 and ENC2. With two motors, M2 is for the leaf that opens first; M1 is for the leaf that closes first. Always pair each ENC connection with the corresponding motor. The MC824L is not a replacement for the MC824H with the LFAB4024.

For the motor cable, use 3 × 1.5 mm² up to and including 10 m, including PE; for the encoder, use 2 × 1 mm² up to 10 m. Choose the wiring and extension according to the environment and MC824HR30 wiring.

MC824HR30 – original wiring for motors, encoders and accessories

Accessory terminals and polarity

MC824HR30 output or inputPower supply and polarity
Auxiliary power supplyThe left SbS terminal is +, the right STOP terminal is − as shown in the illustration below. 24 V DC −30/+50%, total current draw no more than 200 mA.
BLUEBUSTwo wires, with no polarity. They carry both power and data; they do not replace the universal +/− terminals.
FLASH12 V DC, up to 21 W; for example, ELDC. Observe the polarity markings on the DC light and the requirements of the specific output.
OGIGate-open indicator, 24 V DC, up to 4 W.
ELS12 V AC electric lock, up to 15 VA; AC output with no +/− polarity.
OPEN, CLOSE, SbS and STOPCommand inputs use volt-free contacts; do not apply an external voltage to them. Configure STOP for the connected contact type: NO, NC or 8.2 kΩ.

MC824HR30 – auxiliary power supply: left SbS is positive, right STOP is negative

Do not connect relay-type photocells to BlueBUS. For EPMB, select the address for the required function and run device learning after wiring; BlueBUS wiring and addressing. The specified 12 V DC output is not suitable for the 230 V ELAC warning light.

Initial start-up and safety checks

A sensitive safety edge. Plan where it will be installed and verify the safety of the entire gate. Force adjustment alone does not replace this protection.

  1. Disconnect the mains and any backup battery. With the drive released, manually check the full travel, alignment of the pivots, secure attachment of the gate leaf, both stops and drainage. The gate leaf must not catch or move on its own.
  2. Re-engage the release mechanism. Check the motor wires, PE, safety devices and accessories; for 24 V systems, also check the encoder pairings.
  3. After switching on, check the input status and device learning on the control unit. The motor type and safety inputs must be configured correctly before learning the travel limits.
  4. During the first movement, watch the direction and sequence of the gate leaves. If the direction is wrong or the gate moves unexpectedly, stop immediately, disconnect the power and correct the wiring. Do not try to fix the problem by increasing the force.
  5. Learn the end positions according to the instructions for the specific control unit. Then test the full cycle, slowdowns, stops, release mechanism, every pair of photocells and the safety edge.
  6. Before handover, have the effective forces professionally measured and verify protection at hazardous points. The user must be shown how to operate and manually release the gate and how to maintain it.

Permanently display a legible manual drive-release instruction at the release point. Do not hand over the gate for use until the complete system, including its safety devices, has passed testing.

MC824HR30: selecting LFAB4024

On the 12-position motor selector, set DIP 3 = ON; all other DIP switches 1–12 = OFF. Applies to the LFAB4024 on the MC824HR30. Set the selector with the power disconnected; after changing it, the end positions must be learned again. The TO4024 group display also includes the LFAB4024.

MC824HR30 – selecting LFAB4024, DIP 3 ON and all others OFF

MC824HR30: device learning

Press and hold simultaneously Open and Stop/Set. Release the buttons when L1 and L2 start flashing rapidly, after approximately 3 seconds. STOP stays lit during learning. When learning is complete, L1 and L2 go out; L3 and L4 may flash because the positions have not yet been learned. Repeat device learning after changing the BlueBUS or STOP devices.

MC824HR30: automatic position learning

  1. After checking the wiring and learning the devices, press and hold simultaneously Stop/Set and Close. When L3 and L4 start flashing rapidly, after approximately 5 seconds, release the buttons.
  2. Watch as M1 slowly closes to the stop, M2 slowly closes to the stop, M2 and M1 slowly open to the stops, and both leaves close quickly. If the direction is incorrect, stop the procedure immediately.
  3. At the end of closing, L3 and L4 go out, confirming that learning was successful.

For a single motor unit, M2/ENC2 is connected. If the photocells or STOP input are triggered during learning, the procedure is cancelled and L1 starts flashing. Remove the cause and repeat the learning procedure. Other modes: MC824HR30 position learning.

Settings, remotes and reset

Force, speed, automatic closing pause, partial opening and leaf sequence are set by the control unit, not by the underground motor itself. After changing a setting, check that the safety forces and protective devices are working correctly.

Deleting radio remotes and resetting the control unit are different procedures. A reset will not fix mechanical binding; after settings are deleted, the corresponding learning procedure must be carried out again. Choose the procedure according to the specific control board and installed receiver.

Troubleshooting

SymptomWhat to check
The gate leaf cannot be moved manuallyRelease mechanism, condition of the hinges, levers, axial mounting and any foreign objects in the housing. Do not force a jammed gate to move.
The motor runs, but the leaf does not moveEngagement of the release mechanism and linkage between the levers. Disconnect the power before carrying out any work.
Incorrect direction or sequenceMotor and wiring assignment. Also check M1/ENC1 and M2/ENC2, the selector switch and repeat the learning procedure.
The gate stops or reversesFree movement, obstructions, photocells, safety edge and the control unit's LED signals. Safety tests; do not increase the force without first removing the cause.
Water in the housingDrain, sediment, water backing up and condition of the wiring. If a cable is damaged or water has entered a connection, take the equipment out of service.
The remote control does not respondCheck the remote's battery and pairing, the installed receiver and the antenna; pairing the remote.

Maintenance

Carry out an inspection at least every 6 months, and more often with intensive use or in harsh conditions. Disconnect both the mains power and backup power before cleaning or carrying out any work. Do not use a damaged or binding gate until it has been repaired.

  • Clean the foundation box and drain; remove mud, leaves and foreign objects.
  • Check for corrosion and inspect the cable, screws, levers, hinges and mechanical stops.
  • Lubricate the designated moving contact surfaces and linkage between the levers; check that the release mechanism works.
  • After maintenance, test manual operation, a complete automatic cycle and all protective devices. Check the forces and settings.

Estimated service life

Service life depends on the combined load on the gate leaf and operating conditions. The following indices apply to the length and weight combinations shown; the operating limits. The graph shows the estimated number of cycles with regular maintenance; it is not a guarantee or a number of years. The horizontal axis shows the sum of the indices as a percentage, and the vertical axis shows the number of cycles.

Characteristics of the complete automation systemIndexService life graph
Gate leaf weight2.01–3 m3.01–4 m

L-FAB – estimated number of cycles according to the sum of load indices as a percentage

Up to 150 kg10%20%
151–350 kg20%30%
351–550 kg30%40%
551–650 kg40%50%
Additional factorAdd
Temperature above 40 °C or below 0 °C; humidity above 80%15%
Solid infill gate leaf20%
Windy conditions15%

Example: a 3 m / 500 kg gate leaf has an index of 30%. In windy conditions, add 15%, for a total of 45%. Add any other relevant factors as well. This calculation does not replace checking the suitability of the gate leaf and the safety forces.

Technical specifications and dimensions

ParameterNICE LFAB4024
Motor voltage24 V DC
Control unit for the new systemMC824HR30; control unit power supply: 230 V AC
Peak current / power consumption5 A / 120 W
Maximum torque300 Nm
No-load speed1 rpm
Approximate 90° opening at rated speedApproximately 18 s; acceleration and deceleration increase the time.
Cycles/h at rated load60 cycles/h
Standard opening angleUp to 110°; up to 360° with BMA1 for a gate leaf up to 3.5 m
Protection rating / temperatureIP67 / −20 to +50 °C
Motor power cable2 m; connections outside the foundation box
Motor weight only12.5 kg
CapacitorNot used, unlike with a 230 V motor
LFABBOX4Steel box: 14.4 kg; the motor, box and release mechanism are separate components
Dimensions of the assembly with the current box400 × 325 × 152 mm; check the actual box supplied before pouring concrete

Peak input power and maximum torque are not continuous-duty ratings. Actual operating time depends on the angle, load and control unit settings. When planning the excavation and gate leaf height, refer to the dimensioned drawing for the specific box.

NICE L-FAB – dimensions of the assembly with the current foundation box

Product view

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE L-Fab LFAB4024 – standalone underground operator for a swing gate leaf up to 4 m/650 kg