NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg
NICE-LFAB4000
within 3 days
€299.96 excluding VAT
€368.95 including VAT

 pcs
Weight
15 kg

Description of NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg

NICE L-FAB LFAB4000 is a standalone underground irreversible drive for one gate leaf. The motor has 230 V AC. It does not include a control unit; for a new setup, use NICE MC800. A double-leaf gate requires two motors and one compatible control unit.

The motor is concealed beneath the hinge axis and does not affect the appearance of the gate. An underground solution is also suitable where there is no room for a linear actuator or articulated arm actuator. The foundation box and gate-leaf bracket form the lower support for the leaf. Secure installation, hinge alignment and effective water drainage are essential.

The 230 V version is also suitable for higher wind loads, but solid infill, gate height and wind reduce the permitted dimensions. Suitability must be assessed based on the entire gate and the application chart.

Quick navigation
Controls and accessoriesMotor and box
Choosing a driveKits
InstallationStops
Motor wiringAccessory terminals
Initial startupSettings and controls
Manual releaseTroubleshooting
MaintenanceService life
Specifications and dimensionsPDF manual

Controls and compatible accessories

Choose the equipment to match the installed control unit. For an older control board, follow its own wiring diagram and settings; a newer diagram is not a universal guide for every generation.

What Why Type
Control unit

Controls one or two motors. Motor wiring.

Warning light

Indicates movement. The voltage and maximum current draw must match the FLASH output.

  • LED warning light with antenna ELAC

Other warning lights select according to the voltage and current draw of the FLASH output on the specific control unit.

Photocells

Passage protection depends on the positioning and operating mode of the photocells; wiring.

The MC800 supports both BlueBUS and relay photocells in the same setup. The AUX relay inputs must be configured for the relevant function.

  • Wired relay type - EPM
  • Reflective relay type - EPMOR
  • Vandal-resistant wired relay type - EPMA
  • Wired BlueBUS type - EPMB, EPLB, EPSB
  • Reflective BlueBUS type - EPMORB
  • Wireless with IBW interface – EPMOW
  • Adjustable wired BlueBUS type - F210B
  • BlueBUS with battery-powered transmitter – FT210B
  • Wired BlueBUS type - EPMOB

EPMOW requires the radio interface IBW connected to BlueBUS. The FT210B has a battery-powered transmitter on the gate leaf and a receiver connected to BlueBUS by two wires; it also transmits the status of the safety edge.

Safety edgeA safety edge is required to limit impact forces. The positioning and operation of the safety device must be checked across the entire gate.
  • STOP input on the MC800. Select the edge type and connection according to the safety input on the control board in question.
Transmitter

Remote control compatible with the coding of the installed receiver. ON3ELR uses OXILR; ON3EBD uses OXIBD. Remote control pairing.

Receiver

Radio receiver for the control unit's SM connector. The receiver and transmitter must use the same coding. OXILR and OXIBD use different radio systems.

  • GSM modules operate the control via a volt-free NO contact; select the power supply according to the specific module.
Antenna

Improves remote control reception. With the OXIBD, connect the antenna to its antenna terminals.

  •  integrated into the warning light ELAC
  • standalone antenna ABFKIT
Keypad

Access by code. Choose the EDSWG according to the receiver; the EDSB uses BlueBUS and device registration.

Key switch

Key-operated control via a volt-free NO contact connected to the control unit's command input.

  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder, EKSEU
  • recessed, with a standard cylinder EKSI
  • recessed, with a European cylinder EKSIEU
Card readers

Access by fob or card. Connect the ETPB to BlueBUS; run device registration after connecting.

  • ERA Transponder Reader ETPB
Electric locks

Additional locking for the gate leaf. The control unit releases the lock before opening. Selection depends on the length, stiffness and load of the gate leaf; lock output.

Motor, foundation box and release mechanism

Assembly partWhat you need
LFAB4000 standalone motorOne motor, a 2 m power cable and a mechanical closing stop. The motor has no separate encoder cable; it is controlled by the control unit.
Foundation boxLFABBOX4 made of steel with a cataphoresis treatment or stainless steel LFABBOX4I. They use the same mounting method; the box includes a gate-leaf lever and a mechanical opening stop. Sold separately.
Manual releaseNICE BMA3 with a lever key, required for manual movement of the gate leaf during a power failure. Sold separately.
Controls and safetyNICE MC800, receiver, remote controls, photocells and safety equipment as required for the specific gate. Not built into the standalone motor.
Wider opening angleNICE BMA1 with a chain drive, opening up to 360° for gate leaves up to 3.5 m. Requires suitable clearance and external mechanical stops.

The motor and box can be used with either right- or left-hand gate leaves. LFABBOX4 and LFABBOX4I differ in material and surface finish; even a stainless-steel box does not replace drainage. When replacing, check the actual box, levers and release mechanism.

Kits for one or two gate leaves

The number of motors corresponds to the number of gate leaves. Two motors do not increase the permitted length or weight of an individual gate leaf. When comparing kits, check the boxes, release mechanism, control unit and safety equipment.

One gate leafStandalone motorTwo gate leaves

Kit for one gate leaf

NICE L-Fab LFAB4000 drive kit for a single-leaf gate up to 4m/650kg

230 V AC motors. Choose the kit contents and equipment according to the kit details.

LFAB4000 standalone motor

NICE L-Fab LFAB4000 - standalone underground drive for a swing gate with a leaf up to 4m/650kg

One 230 V AC motor. The box, release mechanism and control unit are selected separately.

Kit for two gate leaves

NICE L-Fab LFAB4000 drive kit for a double-leaf gate - one leaf 4m/650kg

230 V AC motors. Choose the kit contents and equipment according to the kit details.

Gate length, weight and operation

4 m and 650 kg are separate maximum limits; they do not apply simultaneously. Read the permitted weight for the given length from the graph: the horizontal axis shows gate-leaf length in metres, and the vertical axis shows its weight in kilograms. For a gate leaf around 3 m long, the limit is approximately 500 kg; at 3.5 m, approximately 400 kg. At 4 m, the permitted weight is lower still. These values do not replace an assessment of movement resistance, infill and wind exposure.

NICE L-FAB – graph of permitted weight by length of one gate leaf

PropertyLFAB4000
Motor voltage230 V AC
Control unit for the new assemblyMC800
Cycles per hour at rated loadMaximum 20 cycles/hour
Magnetic encoderNo separate encoder cable
Battery backupConfigure the assembly according to the selected control unit

One cycle consists of opening and closing. When opening to 180° with BMA1, the stated number of cycles per hour is halved. This is not designed for unlimited continuous operation. Smooth manual movement and correct mechanical alignment must be maintained throughout the entire travel.

Installing the box and drive

Install on a sturdy gate that operates smoothly. The gate leaf must move easily by hand, without sticking or moving on its own. The drive will not fix faulty hinges or an unstable mounting. Also check for pinch points at the hinges and between the gate leaves; a pedestrian gate built into a leaf must have protection that prevents operation when it is open.

Drainage and cabling

  1. Prepare an excavation large enough for the specific box, secure concrete anchoring, water drainage and cable conduits. Check the dimensions against the actual box supplied before pouring the concrete.
  2. Run a separate cable conduit and an effective drain into the box. The drain must not be blocked or routed to a location where water can flow back into the box.
  3. Install the box level. The box pivot axis must align precisely with the gate-leaf hinge axis throughout the entire range of movement. Check the position and installation height before pouring the concrete.
  4. Securely set the box in concrete and allow the concrete to cure sufficiently before installing the drive. Protect the drain and threads from dirt during the work.

L-FAB – separate water drainage and cable routing from the foundation box

L-FAB – foundation box axis aligned with the gate-leaf hinges

L-FAB – levelling and concreting the foundation box

For more practical guidance, see the foundation box installation instructions. Ingress protection rating IP67 describes the motor's protection; it is not a reason to leave the box submerged for long periods.

Installing the motor and attaching the gate leaf

  1. Place the motor in the box in the correct orientation and secure it at the prepared mounting points with washers and nuts.
  2. Install the ball, control bracket, release lever and connecting lever according to the original drawing. The parts must move freely and be connected correctly.
  3. Attach the gate leaf to the load-bearing lever with bolts or an equivalent strong weld. For the specified bolted connection, the tightening torque is 30 Nm. When welding, protect the motor, plastic parts and release mechanism from heat.
  4. Lubricate the moving contact surfaces and check that they move freely. Route the power cable without tension or risk of damage; the cable joint must not be inside the box.
  5. After adjusting the stops and completing the tests, fit the box cover and secure it with screws. Keep the release mechanism accessible.

L-FAB – mounting the motor in the foundation box

L-FAB – 1 release lever, 2 connecting lever, 3 ball, 4 bracket, 5 box pin

L-FAB – securing the gate leaf with screws tightened to 30 Nm or with a suitable weld

Mechanical stops and opening angle

The standard opening angle is up to 110°. If the gate does not have suitable external stops, install the supplied: stop 1 on the motor for closing and stop 2 in the box for opening. The stops must bring the gate leaf to a halt in the required position without it hitting the surrounding structure. These are mechanical stops, not electrical limit switches.

L-FAB – 1 closing stop on the motor, 2 opening stop in the box

For a wider opening angle, use NICE BMA1 with a chain drive. The accessory is limited to gate leaves up to 3.5 m; suitable external stops and safe clearance are also required with this installation.

Manual release in the event of a power failure

Before releasing the drive, stop the gate and disconnect the power supply and any backup battery. Hold the gate leaf, especially in windy conditions or on sloping ground. Keep people clear of its path.

  1. Slide open the release access cover.
  2. Insert the supplied BMA3 lever key and turn it 90° clockwise.
  3. The gate leaf can now be moved manually, slowly and without force.

L-FAB – manual release procedure using the lever key

Re-engaging the drive

  1. Move the gate leaf to approximately the midpoint of its travel.
  2. Slide open the cover, insert the key and turn it 90° counterclockwise.
  3. Gently move the gate leaf until the mechanism re-engages with a distinct click. Check that the drive is properly locked before restoring power.

L-FAB – re-engaging the drive after manual release

Connecting the motor and control unit

Disconnect the mains power and backup supply before carrying out any work. The mains supply must allow complete and safe disconnection, and the motor and assembly must be correctly connected to protective earth. Do not place any cable joint or terminal block inside the foundation box. Make the connection in a suitable protected enclosure outside the box.

LFAB4000 conductorConnection to MC800
BlackOPEN – phase for opening.
BrownCLOSE – phase for closing.
GreyCOMMON – motor common wire. This is not the +24 V accessory Common.
Yellow-greenProtective earth (PE).

Use 4 × 1.5 mm² cable for the motor wiring for lengths up to 10 m. For a single motor unit, use output M2; for two units, use M1 and M2 according to the order of the gate leaves. LFAB4000 has a built-in 7 µF capacitor; do not add another capacitor to the general control unit wiring diagram without checking the specific motor.

MC800 – original wiring for 230 V motors, BlueBUS and relay photocells without Phototest

The diagram above shows relay photocells without Phototest and with Standby disabled. The AUX terminals must be assigned the PHOTO, PHOTO1 or PHOTO2 function. Configure unused inputs according to the selected operating mode; do not copy the jumpers shown in a diagram for a different setting. For details, see: MC800 relay wiring. LFAB4000 does not have electrical limit switches (FCA/FCC).

Terminals and accessory polarity

MC800 terminalsPower supply and polarity
3 / 43 = negative (0 V), 4 = positive (+24 V DC Common). Maximum total current draw for accessories: 200 mA.
5 / 3OUTSTB: 5 = positive, 3 = negative, 24 V DC, maximum 4 W. Use depends on Phototest and Standby.
6 / 7 BLUEBUSTwo non-polarized wires; power and data for compatible BlueBUS devices.
FLASH230 V AC, maximum 21 W; e.g. ELAC. The AC output has no +/− polarity. ELDC 12 V DC must not be connected here.
1 / 2 EL12 V AC electric lock, maximum 15 VA; no +/− polarity.
4 / 13 SbSVoltage-free NO contact for step-by-step commands. Do not apply external voltage to the input.
EPM TX and RXAt the photocell 1 = positive, 2 = negative. RX contacts 4 = COM, 5 = NC are voltage-free. In the diagram without Phototest: TX1 and RX1 → control unit 4 (+), TX2 and RX2 → control unit 3 (−); RX4 → control unit 4, RX5 → configured PHOTO input 8, 9 or 10.

EPM – power terminals 1 positive and 2 negative, receiver contacts 4 COM and 5 NC

With Phototest or Standby enabled, the transmitter power supply and jumpers are different. Use the corresponding MC800 photocell diagrams and AUX input settings. Contacts and BlueBUS do not have a universal +/− polarity.

Initial start-up and safety checks

A sensitive safety edge. Plan its position and check the safety of the entire gate. Force adjustment alone does not replace this protection.

  1. Disconnect the mains power and any backup battery. With the drive released, manually check the entire travel path, the axial mounting, secure attachment of the gate leaf, both stops and drainage. The gate leaf must not stick or move on its own.
  2. Re-engage the release mechanism. Check the motor wiring, PE, safety devices and accessories.
  3. After switching on, check the input status and device learning on the control unit. The motor type and safety inputs must be configured correctly before learning the travel limits.
  4. During the first movement, check the direction and sequence of the gate leaves. If the direction is wrong or movement is unexpected, stop immediately, disconnect the power and correct the wiring. Do not try to fix this by increasing the force.
  5. Learn the end positions according to the instructions for the specific control unit. Then test a complete cycle, slowdowns, stops, manual release, each pair of photocells and the safety edge.
  6. Before handover, have the effective forces professionally measured and check the protection of hazardous areas. The user must be shown how to operate and manually release the gate, and how to maintain it.

When disengaged, permanently affix a legible manual release instruction. Put the gate into service only after successfully testing the complete assembly, including the safety devices.

For the MC800, first carry out BlueBUS and STOP device learning, then travel and mechanical stop learning. The LFAB4000 is an electromechanical motor; do not select hydraulic mode. With a single unit, learn the M2 motor positions.

Settings, transmitters and reset

Force, speed, automatic closing pause, partial opening and leaf sequence are set by the control unit, not by the underground motor itself. After changing a setting, recheck safe operating forces and the function of the safety devices.

Deleting radio transmitters and resetting the control unit are two different operations. A reset will not fix mechanical binding; after deleting the settings, the appropriate learning procedure must be performed again. Choose the procedure according to the specific control board and installed receiver.

Troubleshooting

SymptomWhat to check
The gate leaf cannot be moved manuallyRelease, hinge condition, levers, axial alignment and foreign objects in the housing. Do not force a jammed gate to operate.
Motor runs, gate leaf does not moveEngagement of the release mechanism and connection of the levers. Disconnect the power supply before carrying out any work.
Incorrect direction or sequenceMotor and wiring assignments. Check OPEN/CLOSE and motor M2 when using a single leaf.
The gate stops or reversesFree movement, obstructions, photocells, safety edge and the control unit's LED signals. Safety tests; do not increase the force without identifying and addressing the cause.
Water in the housingDrainage, sediment, water ingress and the condition of the wiring. Take the equipment out of service if a cable is damaged or water has entered a connection.
Remote control does not respondCheck the transmitter battery, its pairing, the installed receiver and the antenna; transmitter pairing.

Maintenance

Carry out an inspection at least every 6 months, and more often in case of intensive use or harsh environmental conditions. Disconnect both the mains supply and backup power before cleaning or carrying out any work. Do not use a damaged or binding gate until it has been repaired.

  • Clean the foundation box and drain; remove mud, leaves and foreign objects.
  • Check for corrosion and inspect the cable, screws, levers, hinges and mechanical stops.
  • Lubricate the specified moving contact surfaces and lever connections; check that the release mechanism works.
  • After maintenance, test manual operation, a complete automatic cycle and all safety devices. Check the forces and settings.

Estimated service life

Service life is affected by the combined load of the gate leaf and operating conditions. The following indices apply to the specified combinations of length and weight; the operating limits. The graph shows an estimated number of cycles with regular maintenance, not a guarantee or a number of years. The horizontal axis shows the sum of the indices as a percentage, and the vertical axis shows the number of cycles.

Characteristics of the complete automation systemIndexService life graph
Gate leaf weight2.01–3 m3.01–4 m

L-FAB – estimated number of cycles by total load index, in percent

Up to 150 kg10%20%
151–350 kg20%30%
351–550 kg30%40%
551–650 kg40%50%
Additional factorAdd
Temperature above 40 °C or below 0 °C; humidity above 80%15%
Solid gate leaf infill20%
Wind exposure15%

Example: a 3 m / 500 kg gate leaf has an index of 30%. In a windy location, add 15%, for a total of 45%. Add any other relevant factors as well. This calculation does not replace checking the suitability of the gate leaf and the safety forces.

Technical specifications and dimensions

ParameterNICE LFAB4000
Motor voltage230 V AC, 50/60 Hz
Control unit for the new assemblyMC800; control unit supply 230 V AC
Peak current / power consumption1.5 A / 340 W
Maximum torque500 Nm
No-load speed0.8 rpm
Approximate 90° opening time at nominal speedApproximately 23 s; acceleration and deceleration increase the time.
Cycles/h at rated load20 cycles/h
Normal opening angleUp to 110°; up to 360° with BMA1 for a gate leaf up to 3.5 m
Ingress protection / temperatureIP67 / −20 to +50 °C
Motor power cable2 m; connections outside the foundation box
Motor weight only14.3 kg
CapacitorBuilt-in 7 µF
LFABBOX4Steel box, 14.4 kg; the motor, box, and release mechanism are separate components
Dimensions of the assembly with the current box400 × 325 × 152 mm; check the actual box supplied before pouring the concrete

Peak power consumption and maximum torque are not continuous-duty ratings. Actual movement time depends on the angle, load, and control unit settings. When planning the excavation and gate leaf height, refer to the dimensioned drawing for the specific box.

NICE L-FAB – dimensions of the assembly with the current foundation box

Product view

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg

Product: NICE L-Fab LFAB4000 – standalone underground operator for a swing gate leaf up to 4 m/650 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.