Description of NICE Big-Fab BFAB5024 – standalone underground operator for a swing gate leaf up to 5 m / 900 kg

NICE Big-Fab BFAB5024 is a standalone underground irreversible drive for one gate leaf. It has a 24 V DC motor with a magnetic encoder. It does not include a control unit; for a new setup, use NICE MC824HR30. A double-leaf gate requires two motors and one compatible control unit.

The drive is concealed beneath the hinge axis and does not affect the gate's appearance from either side. An underground solution is also suitable where there is no room for a linear actuator or articulated-arm actuator. The box with its supporting lever forms the lower pivot for the gate leaf; it must be securely installed, aligned with the hinges, and drained.

BFAB5024 is also designed for more intensive use with larger gate leaves. At rated speed, a 90° opening takes approximately 23 seconds; acceleration, deceleration, and load affect the time. Limit: 5 m / 900 kg does not mean 900 kg at a length of 5 m.

24 V is the motor voltage; the MC824HR30 is mains-powered at 230 V AC. For a complete setup, also select a box, manual release, controls, and safety devices.

Quick navigation
Controls and accessoriesMotor and box
Choosing a driveKits
InstallationStops
Motor wiringAccessory terminals
Initial start-upSettings and controls
Manual releaseTroubleshooting
MaintenanceService life
Specifications and dimensionsPDF manual

Controls and compatible accessories

The wiring and setup instructions below apply to the MC824HR30 with an MCA1R30 board. For an older control unit, choose the wiring instructions for the board actually installed. The MC824L is not a replacement for the MC824H with this motor.

What Why Type
Control unit

Controls one or two motors. Motor wiring.

  • Current model: MC824HR30 with an MCA1R30 board.
  • Older version: MC824HR10 and MCA1R10. Choose the wiring instructions according to the board actually installed.
Warning light

Indicates gate movement. The voltage and maximum current draw must match the FLASH output.

  • LED warning light with antenna ELDC
  • Multifunction light WLT

Other warning lights choose according to the voltage and current draw of the FLASH output on the specific control unit.

Photocells

Passage protection, depending on photocell placement and operating mode; wiring.

  • Wired BlueBus – EPMB, EPLB, EPSB
  • BlueBus reflector-type – EPMORB
  • Wireless with IBW interface – EPMOW
  • Wired, adjustable BlueBus – F210B
  • BlueBUS with battery-powered transmitter – FT210B
  • Wired BlueBus – EPMOB

EPMOW requires the radio interface IBW connected to BlueBUS. The FT210B has a battery-powered transmitter on the gate leaf and a receiver connected to BlueBUS by two wires; it also transmits the status of the safety edge.

Transmitter

Remote control compatible with the coding of the installed receiver. ON3ELR uses OXILR; ON3EBD uses OXIBD. Remote control pairing.

Receiver

Radio receiver for the control unit's SM connector. The receiver and transmitter must use matching coding. OXILR and OXIBD use different radio systems.

  • GSM modules operate the control via a volt-free NO contact; choose the power supply according to the specific module.
Antenna

Choose an antenna to match the frequency of the installed receiver. For the OXIBD, connect it to the antenna terminals.

  • Integrated into the warning light ELDC
  • External antenna ABFKIT
Keypad

Code-based access. Choose the EDSWG to match the receiver; the EDSB uses BlueBUS and device learning.

Key switch

Key-operated control via a volt-free NO contact connected to the control unit's command input.

  • Surface-mounted, standard cylinder EKS
  • Surface-mounted, European cylinder EKSEU
  • Flush-mounted, standard cylinder EKSI
  • Flush-mounted, European cylinder EKSIEU
Electric locks

Additional gate-leaf locking. The control unit releases the lock before opening. An electric lock is required for a gate leaf longer than 3 m; lock output.

Card readers

Access using a token or card. Connect the ETPB to BlueBUS; run device learning after connecting it.

  • ERA Transponder Reader ETPB
Backup power supply

Operation during a power outage. Choose a battery compatible with the control board and control unit connector.

  • Older backup battery PS324

For the current MC824HR30 PSS324. The older PS324 requires CABLA11 and Standby switched off (L4 = OFF); backup connection.

Safety edgeLimits the consequences of contact with an obstacle; provides separate protection for hazardous areas. Tests before handover.
  • An edge with an 8.2 kΩ output connected to STOP, or a suitable assembly with FT210B. STOP wiring.

Motor, foundation box and manual release

Part of the assemblyWhat you need
Standalone BFAB5024One motor with a magnetic encoder, a 2 m power cable and a mechanical closing stop. The box and control unit are not built into the motor.
Foundation boxBFABBOX made of cathodically treated steel or stainless steel BFABBOXI. The box includes a load-bearing lever for the gate leaf and a mechanical opening stop. Sold separately.
Manual releaseNICE BMA3 with a lever key for manually moving the gate leaf in the event of a power failure. Sold separately. For an assembly with BMA3, a NICE PRBM02 mounting lever kit.
Controls and safetyMC824HR30, receiver, remote controls, photocells and safety edge, depending on the specific gate.
Wider opening angleNICE BMA1 with chain drive, up to 360° for gate leaves up to 3.5 m. Suitable clearance and external mechanical stops are required.

The motor has a metal housing. The box can be used for either right- or left-hand gate leaves. The steel and stainless steel versions differ in material and surface treatment; even a stainless steel box does not replace effective water drainage.

When replacing, check the actual motor, box and manual-release versions.

Kits for one or two gate leaves

The kits differ in the number of motors, boxes and manual releases. Two motors do not increase the permitted length or weight of an individual gate leaf. Compare the equipment below for the complete gate.

One gate leafStandalone motorTwo gate leaves

Kit for one gate leaf

NICE Big-Fab BFAB5024 gate operator kit for a single-leaf gate up to 5 m/900 kg

1 × BFAB5024, 1 × BFABBOX, 1 × NICE BMA3.

1 × MC824HR30, 1 × OXIBD, 1 × MYGO4, 1 pair EPMB, 1 × ELDC.

Standalone BFAB5024

NICE Big-Fab BFAB5024 – standalone underground operator for a swing gate with a leaf up to 5 m/900 kg

One 24 V DC motor with encoder. The box, manual release and control unit are sold separately.

Kit for two gate leaves

NICE Big-Fab BFAB5024 gate operator kit for a double-leaf gate – one leaf up to 5 m/900 kg

2 × BFAB5024, 2 × BFABBOX, 2 × NICE BMA3.

1 × MC824HR30, 1 × OXIBD, 1 × MYGO4, 1 pair EPMB, 1 × ELDC.

Gate length, weight and operation

5 m and 900 kg are separate maximum limits. Read the permitted weight for the given length from the graph: the horizontal axis shows the length of one gate leaf in metres, and the vertical axis shows its weight in kilograms. As the gate leaf gets longer, its permitted weight decreases; for a 5 m leaf, it is considerably less than 900 kg.

NICE BFAB5024 – permitted weight by length of one gate leaf

The height of the gate leaf, solid infill, strong winds and hinge resistance can significantly reduce the permitted limits. Before choosing, check the gate’s full manual range of movement and safe operating forces; weight or motor power alone does not guarantee suitability.

PropertyBFAB5024
ApplicationLarger and heavier leaf
Maximum limits according to the graph5 m / 900 kg
Maximum torque400 Nm
Operation at 90° opening45 cycles/hour
BoxBFABBOX / BFABBOXI
Control unit for the new assemblyMC824HR30

One cycle consists of opening and closing. When opening to 180° with BMA1, the stated number of cycles per hour is halved. This is operation under rated load, not unlimited continuous operation.

Installing the box and drive

The gate must be mechanically sound: the leaf must move easily by hand, without sticking or moving by itself. Also check for pinch points at the hinges and between the leaves. If the leaf has a pedestrian gate, it must have a safety contact that disables the drive when the gate is open.

Drainage, alignment and concreting

  1. Prepare an excavation for the specific box, secure it firmly in concrete, and provide cable conduits and a drain. Before concreting, check the dimensions and installation height against the box supplied.
  2. Route a separate cable run and an effective drain into the box. The drain must not be blocked or routed to a location where water can flow back.
  3. Position the box horizontally. The box pivot axis must align precisely with the leaf hinge axis throughout its range of movement. Check the position and installation height before concreting.
  4. Secure the box firmly in concrete and allow the concrete to cure sufficiently. Protect the threads and drain from contamination.

BFAB5024 – separate water drain and cable routing from the foundation box

BFAB5024 – box pivot axis aligned with the leaf hinges

BFAB5024 – levelling and concreting the foundation box

For a practical explanation, see the foundation box installation guide. Protection rating IP67 protects the motor even during temporary immersion; it does not replace drainage and is no reason to leave the box flooded for an extended period.

Fitting the motor and attaching the leaf

  1. Place the motor in the box in the correct orientation and secure it with washers and nuts.
  2. Fit the ball and control bracket onto the box pivot. Install the release lever and connecting link as shown in the drawing. All moving parts must be properly connected.
  3. Attach the leaf to the support arm with bolts or a secure weld. Tighten the illustrated bolted attachment to 30 Nm. When welding, protect the motor, release mechanism and plastic parts from heat; do not weld the leaf to the release sleeve marked as an incorrect location.
  4. Lubricate the specified contact surfaces and check that they move freely. Route the cable without putting it under strain or damaging it; its connection must not be inside the box.
  5. After adjusting the stops and completing the tests, fit the cover and secure it with two screws. Keep access to the release mechanism clear.

BFAB5024 – securing the motor in the foundation box

BFAB5024 – connecting the support arm, connecting link and box pivot

Lever key: 1 release lever, 2 connecting link, 3 ball, 4 control bracket, 5 box pivot. The numbers in the following attachment procedure indicate the installation sequence.

BFAB5024 – bolted leaf attachment at 30 Nm or a suitable weld

Mechanical stops and opening angle

The standard opening angle is up to 110°. If the gate does not have suitable external stops, adjust the supplied stops: 1 is the closing stop on the motor; 2 is the opening stop in the box. They stop the leaf in the required position without it striking the surrounding structure. These are mechanical stops, not electrical limit switches.

BFAB5024 – 1 closing stop on the motor, 2 opening stop in the box

A wider opening angle is possible with NICE BMA1 with chain drive, up to 360°, and only for leaves up to 3.5 m. Suitable external stops and a safe clearance are required for this installation as well. The BMA1 limit does not replace the drive load graph.

Manual release in the event of a power failure

Stop the gate and disconnect the mains supply and any backup battery. Hold the leaf, especially in windy conditions. Keep people clear of its path.

  1. Slide the release access cover aside.
  2. Insert the supplied BMA3 lever key and turn it 90° clockwise.
  3. Now move the leaf slowly by hand, without forcing it.

BFAB5024 – manual release using the BMA3 lever key

Re-engaging the drive

  1. Move the leaf to approximately the midpoint of its travel.
  2. Slide the cover aside, insert the key and turn it 90° counterclockwise.
  3. Gently move the leaf until the mechanism clearly engages. Make sure it is properly locked before restoring power.

BFAB5024 – re-engaging the drive mechanism after manual release

Connecting the motor and control unit

Disconnect the mains supply and backup battery before working on the system. Do not place any cable joint or terminal block inside the foundation box. Use a suitable protected junction box outside the foundation box for cable extensions. Maintain the protective earth (PE) connection.

BFAB5024 wiresConnection
Blue and brown24 V DC motor power pair to output M1 or M2. The control unit reverses the direction of travel by changing the power supply; do not assign fixed +/− polarity to this pair.
Black and greyEncoder pair to ENC1 or ENC2 of the same motor. The encoder wires are not polarity-sensitive.
Yellow-greenProtective earth (PE). Do not use it for the motor or encoder signal.

For the MC824HR30, connect one motor to M2 and ENC2. With two motors, M2 is assigned to the leaf that opens first; M1 to the leaf that closes first. The ENC assignment must match the output of the same motor. If the supplied cable has different markings, check them against the wiring diagram for the specific motor before connecting it.

Wiring for MC824HR30Cross-section and length
Motor, including PE3 × 1.5 mm², max. 10 m.
Encoder2 × 1 mm², max. 10 m.
BlueBUS2 × 0.5 mm² up to 20 m; for lengths over 20 m and up to 40 m, 2 × 1 mm².
FLASH2 × 0.5 mm², max. 20 m.
AntennaShielded RG58; under 5 m recommended, max. 20 m.

Use cables suitable for the environment and protected cable routing. The motor and encoder can be combined in one suitable 5 × 1.5 mm² cable. Other wiring and the mains supply: MC824HR30 wiring.

MC824HR30 – original wiring for motors, encoders and accessories

Terminals and accessory polarity

MC824HR30 output or inputPower supply and polarity
Auxiliary power supplyLeft SbS terminal = +; right STOP terminal = − when viewing the board as shown below. 24 V DC −30/+50%, max. 200 mA total for connected devices.
BLUEBUSTwo wires non-polarized. They carry both power and data; they are not universal +/− terminals.
FLASHWarning light output 12 V DC, max. 21 W; e.g. ELDC. Follow the wiring diagram for the specific light; do not confuse the +/− positions of this output with the SbS/STOP auxiliary power supply.
OGIOpen gate indication, 24 V DC, max. 4 W. For polarity-sensitive lights, follow the markings on the actual output and light.
ELSElectric lock 12 V AC, max. 15 VA; AC supply, with no +/− polarity.
SbS, OPEN, CLOSECommand inputs for a voltage-free NO contact. Do not apply an external voltage to them.
STOPVoltage-free NO/NC contacts or an 8.2 kΩ resistive safety edge, depending on the selected wiring configuration. The input is detected during device learning; do not apply an external voltage to it.

MC824HR30 – auxiliary power supply: left SbS terminal positive, right STOP terminal negative

BlueBUS devices are connected in parallel. Each pair of photocells must have the correct address for the desired response; repeat device learning after making any changes. MC824HR30 photocell wiring and addressing. Relay photocells must not be connected directly to BlueBUS. The ELAC 230 V warning light must not be connected to this 12 V DC FLASH output.

Initial startup and safety tests

The system requires a suitable pressure-sensitive safety edge to limit impact forces. Its type and location are determined by the gate's hazardous areas. Photocells and force settings alone do not replace a complete safety test.

  1. Disengage the drive and manually check the entire travel path, alignment, secure fixing, both stops and drainage. The gate leaf must not stick or move on its own.
  2. Re-engage the release mechanism. Check the motor, encoder, PE, safety devices and accessories.
  3. With the power disconnected, set the correct motor type on the 12-position selector. Then switch on the power and check the input status.
  4. Run device and position learning. Watch the direction and sequence of the leaves; stop immediately if movement is incorrect or unexpected. Disconnect both the mains and backup power before correcting the wiring.
  5. Test the full cycle, slowdowns, stops and release mechanism. Test each pair of photocells, the safety edge and any emergency stop separately.
  6. Have the effective forces professionally measured before handover. Attach the manual release instructions to the drive and explain operation, release and maintenance to the user. Do not use the gate until all tests have been completed.

MC824HR30: selecting the BFAB5024 motor

Set the following on the 12-position selector DIP 6 = ON; all other DIP switches 1–12 = OFF. Make this setting with the power disconnected, before position learning. After changing the motor selection, positions must be learned again.

MC824HR30 – BFAB5024, DIP 6 ON and all others OFF

When controlled via Oview, the BFAB5024 is displayed as BM5024. Use the setting specified for this motor.

MC824HR30: device learning

Press and hold simultaneously Open and Stop/Set. When L1 and L2 start flashing rapidly, after approximately 3 seconds, release the buttons. When complete, STOP must be lit and L1 and L2 must be off; L3 and L4 may flash if positions have not yet been learned. Repeat learning after changing BlueBUS or STOP devices.

MC824HR30: automatic position learning

Before learning, check the wiring, correct motor selection, operation of the safety devices and the mechanical stops. Device learning must be completed first. For a single motor, M2/ENC2 is connected. Keep the movement under observation.

  1. Press and hold simultaneously Stop/Set and Close. When L3 and L4 start flashing rapidly, after approximately 5 seconds, release both buttons.
  2. On a double-leaf gate, M1 slowly closes first to the mechanical stop, followed by M2. Next, M2 and M1 slowly open to the stops, then both leaves close rapidly.
  3. After successful learning, L3 and L4 go out. Check the full cycle and safety devices.

If the direction or sequence is incorrect, stop learning immediately by pressing Open or Close. Disconnect both the mains and backup power before checking the wiring. If swapping M1/M2, also swap the corresponding ENC1/ENC2 pairs; if the direction is reversed, check the motor power pair. Then repeat learning.

If learning is interrupted by a photocell or the STOP input, L1 will flash. Remove the cause and restart automatic learning; do not bypass the safety devices. Detailed procedure and additional MC824HR30 learning modes.

Settings, remotes and reset

The control unit sets the force, speed, automatic closing pause, partial opening and leaf sequence. After making changes, check the safety forces and protective devices. Increasing the force setting is not a solution to poor mechanical installation.

Deleting radio remote controls and resetting the control unit are different procedures. After deleting the settings, the corresponding new learning procedure must be carried out. Use the procedure for the specific control board and receiver.

Troubleshooting

SymptomWhat to check
The gate leaf cannot be moved manuallyRelease, hinges, linkage, alignment and foreign objects in the box. Do not force a jammed gate to operate.
The motor runs, but the gate leaf does not moveEngagement of the release mechanism and linkage. Disconnect the power before carrying out any work.
Incorrect direction or sequenceM1/ENC1 and M2/ENC2 assignment, motor selection and new learning procedure.
The gate stops or reversesFree movement, obstructions, photocells, the safety edge and Control unit LED signal. Once the cause has been addressed, carry out safety tests.
Water in the boxDrain, deposits, water backing up and wiring. If a cable is damaged or water has entered a connection, take the unit out of service.
Remote control does not respondCheck the remote control battery, its assignment, the receiver and the antenna; remote control pairing.

Maintenance

Have professional maintenance carried out at least every 6 months, or more frequently with intensive use or in harsh environments. Disconnect the mains power and backup supply before cleaning or carrying out any work. Do not use a damaged or sticking gate until it has been repaired.

  • Remove mud, leaves and stones from the box, and keep the drain clear.
  • Check for corrosion and inspect the cables, screws, hinges, linkages and stops; replace worn parts.
  • Lubricate the designated moving contact surfaces via the grease nipple with a suitable lubricant. Check that the gate moves freely and that the release mechanism works.
  • After maintenance, test manual operation, a complete automatic cycle and every safety device.

BFAB5024 – lubricating the moving bearing via the grease nipple

Estimated service life

Service life depends on the weight and length of the gate leaf, as well as the environment. Add the index for the relevant combination and any other applicable factors. The following must be met first: application limits; the service life index does not permit the use of a heavier gate leaf. The chart shows an estimated number of cycles with regular maintenance, not a guarantee or a number of years. The horizontal axis shows the sum of the indices as a percentage; the vertical axis shows the number of cycles.

For temperatures above 40 °C or below 0 °C, or humidity above 80%, add 15%. A solid infill adds 20%, and a windy environment adds a further 15%.

Properties of the complete automation systemIndexService life chart
Up to 150 kg2.01–3 m: 10%
3.01–4 m: 20%
4.01–5 m: 30%
Estimated number of cycles by total service life index
151–350 kg2.01–3 m: 20%
3.01–4 m: 30%
4.01–5 m: 40%
351–550 kg2.01–3 m: 30%
3.01–4 m: 40%
4.01–5 m: 50%
551–750 kg2.01–3 m: 40%
3.01–4 m: 50%
4.01–5 m: —
751–900 kg2.01–3 m: 50%
3.01–4 m: —
4.01–5 m: —
Temperature / humidity+15%
Solid infill+20%
Windy environment+15%

Example: a 3 m / 500 kg gate leaf has an index of 30%. In a windy environment, add 15%, for a total of 45%. Any other applicable factors should also be added.

The combinations shown apply to gate leaves longer than 2 m. For a shorter gate leaf or an unclear combination, contact us with the length, weight, infill type and required number of cycles.

Technical specifications and dimensions

ParameterNICE BFAB5024
Motor voltage24 V DC, separate from the control unit's mains power supply
Control unit for the new setupMC824HR30 / MCA1R30, 230 V AC mains
EncoderMagnetic, with a separate ENC connection
Peak current / power consumption7 A / 170 W
TorqueMaximum 400 Nm; rated 100 Nm
SpeedNo load: 0.8 rpm; at rated torque: 0.65 rpm
90° openingApproximately 23 s at rated movement speed, excluding acceleration and deceleration.
Operation at 90° opening45 cycles/h at rated load; at 180° with BMA1, half that
Standard opening angleUp to 110°; with BMA1, up to 360° for a gate leaf up to 3.5 m
Protection rating / operating temperatureIP67 / −20 to +50 °C
Power cable2 m; extensions and connections must be outside the box
Motor weight13.3 kg; the box is calculated separately
Steel boxBFABBOX – 20.3 kg
Box dimensions according to the drawing400 × 325 mm, body height 152 mm; also observe the pin position and hinge axis

The maximum torque and peak power consumption are not continuous-duty ratings. When planning the excavation and gate leaf height, refer to the drawing and the box actually supplied. The dimensions of the motor alone do not replace the box dimensions.

NICE BFABBOX – box dimensions and load-bearing pin position

Product view

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Big-Fab BFAB5024 – standalone underground operator for a swing gate leaf up to 5 m / 900 kg

Product: NICE Big-Fab BFAB5024 – standalone underground operator for a swing gate leaf up to 5 m / 900 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.