NICE SNA2 - replacement control unit for NICE Spinbus SN6021 operators
| Product availability: | replaced | The product is no longer manufactured, but fortunately it has been replaced by a newer model. |
|---|
Description of NICE SNA2 - replacement control unit for NICE Spinbus SN6021 operators
The control unit has been replaced. Its fully compatible successor is NICE-SNA20.
It is more cost-effective to purchase the complete NICE Spinbus operator than to buy the control unit separately. NICE Spinbus operator.
NICE SNA2 control unit is compatible with garage door operators NICE Spinbus SN6021. Includes an SM for connecting radio receiver (SMXI, OXI, ...) from remote controls (Flor, Era Flor, Era One, Era Inti, ...).
Supports BlueBus, which allows accessories to be conveniently connected (photocells, warning light, card readers, key switches, etc.) using just a two-core cable, with no need to observe polarity.
Thanks to the 24V technology, in standby mode the control unit with a connected control signal receiver uses just 2 W.
Diagnostics using warning light.
After automatically assessing the gate leaf length, the acceleration and deceleration intervals for opening and closing are set. You can also adjust the force, speed etc. See programming the operator control unit. Obstacle detection throughout the gate leaf's entire travel ensures safe motor operation.
NICE SNA2 control unit is suitable for the climate in Slovakia and meets all European safety standards.
Accessories compatible with the NICE SNA2 control unit
We recommend purchasing these optional compatible accessories for the control unit:
| What | Why | Type |
|---|---|---|
| Warning light | The warning light flashes to indicate gate movement—ideal for exits with poor visibility. It also has a built-in antenna for increased remote-control range. | |
| Photocells | When closing, they detect obstacles and stop the gate—so it won't hit a car or anyone. | - MoonBUS (MOFB) |
| Transmitter |
For remote operation of the gate. |
- FloR (Flo2R-s, Flo4R-s) |
| Receiver | Required for remote operation of the gate. | - OXI - SMXI |
| Antenna | For improved remote control range. | - integrated into the warning light LUCYB, MLBT - ABFKIT antenna only, or ABF |
| Keypad | If you forget your remote control, or if you have many vehicles or people coming and don't want to give everyone a remote or open the gate manually. | - MOTXR |
Manual for the NICE SNA2 control unit and NICE Spinbus SN6021 operator
Download the manual for the NICE SNA2 control unit and NICE Spinbus SN6021 operator here:
Manual for the NICE SNA2 control unit and NICE Spinbus SN6021 operator
Wiring the NICE SNA2 control unit for the NICE Spinbus SN6021 operator
...to the mains
Simply plug the operator into a power outlet.
...accessories
Warning: Before connecting, disconnecting, or changing the wiring of accessories, remember to disconnect the power supply, either at the circuit breaker, by removing the power fuse, or by disconnecting the backup battery.
NICE SNA2 control unit for the operator NICE Spinbus SN6021 provides the following inputs and outputs for accessories:
| Input/output | Description | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Programmable output whose operation can be configured by Level II programming for L4; see Level II programming, L4 – Output indicator. It can be programmed for the following devices:
|
|||||||||||||
| Input for parallel connection of compatible devices using BlueBUS using a two-core cable that carries both the power supply and the communication signal. | |||||||||||||
| STOP (Stop) |
Input for devices that stop gate movement. The following devices can be connected:
|
||||||||||||
| Input for devices that step through gate movement (see Step-by-step gate movement). Normally open (NO) devices can be connected. | |||||||||||||
| AERIAL (Antenna) |
input for the radio receiver antenna. The antenna is usually built into the warning light, e.g. NICE LUCYB, NICE MLBT, or an external antenna can be installed separately NICE ABFKIT. |
Operator fuses
|
In the drive there are two fuses:
|
Standard wiring diagram:
Wiring
Route the cables to the control unit and connect them as follows:
| 1. Press the white cover in and turn it | 2. Pass the cables through the opening, route the antenna cable through the side eyelet, and connect all the cables. |
|---|---|
|
![]() |
Drive photocells
The very user-friendly BlueBUS technology allows you to power and control 2 pairs of photocells using a two-core cable.
WIRING MULTIPLE PAIRS OF PHOTOCELLS NICE MOFB TO THE DATA NETWORK NICE BLUEBUS
Position the photocells around the gate or door according to the example configurations for complete wiring, and set the jumpers according to the photocell jumper table NICE MOFB for the gate drive. To prevent interference between pairs positioned close to one another, follow these example configurations, and observe the orientation of the transmitters TX and receivers RX. Connect the photocells in parallel as shown (polarity does not need to be observed):
Example photocell wiring configuration
| Sectional garage door | Up-and-over garage door |
|---|---|
![]() |
![]() |
If you need the photocells to function as gate openers (see FA1 and FA2 in the figure), i.e. when a vehicle passes between their optical axes, they open the gate, you must cut jumper A on both the transmitter TX and receiver RX, see figure:
Jumper table for NICE MOFB gate-drive photocells
|
Connecting multiple pairs of photocells to the BlueBUS system is done by setting different combinations of jumpers, with each connected pair requiring a unique jumper combination. Make sure that no two pairs on the same BlueBUS data network have the same combination. For each pair of photocells, set the jumper on both the TX transmitter and RX receiver to the same value. If a jumper configuration uses only one jumper, always store the second one in the unused compartment, as shown in the figure on the left. |
| Photocell pair designation | Jumper setting using a combination of jumpers |
|---|---|
| FOTO | ![]() |
| FOTO II | ![]() |
| FOTO 1 | ![]() |
| FOTO 1 II | ![]() |
| FOTO 2 | ![]() |
| FOTO 2 II | ![]() |
|
FOTO 3 WARNING: CONFIGURATION NOT PERMITTED! |
![]() |
|
FA1 |
![]() |
|
FA2 |
![]() |
If, for any reason, a photocell needs to be replaced, simply set it to the same jumper as the original one; there is no need to run the device learning procedure.
Radio receiver for operators
![]() |
SNA2 control unit NICE Spinbus SN6021 operator features an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted from the remote controls, and is therefore required to operate the sliding gate remotely using a remote control. |
Pairing the remote controls with the operator
Visit our guide to pairing a remote control with the operator, or click:
Learning the connected operator devices
After connecting, disconnecting, or changing the wiring of any accessories on the BlueBUS inputs and the accessory learning procedure the accessory learning procedure. The operator will alert you that this procedure is required by flashing LEDs L1 and L2.
![]() |
|
Garage door travel learning
For the door to operate correctly (in particular, to calculate acceleration and deceleration distances and partial opening), the operator must learn the door travel length. During this procedure, the operator moves the door from one end stop to the other and determines its travel length.
Operator programming
The SNA2 control unit for the Spinbus SN6021 operator lets you program several functions, either by enabling or disabling a function using Level I programming,or by setting a default parameter using Level II programming..
SNA2 control unit has three buttons for operating and programming the operator:
![]() |
Button | Function |
|---|---|---|
| Open | Pressing this button commands the operator to open the door. In programming mode, it also moves the programmed parameter value up. | |
| Stop/Set | Pressing this button commands the operator to stop the door. Press and hold it for 5 seconds to enter Level I programming. Press and hold it again to enter Level II programming. for the current LED. | |
| Close | Pressing this button commands the operator to close the door. In programming mode, it also moves the programmed parameter value down. |
Level I programming
At Level I, programming enables/disables the given function. When a function is enabled, the corresponding LED on the control unit lights up. All functions are disabled by default.
To enter Level I programming, press and hold the “Stop/Set” button for approx. 5 seconds, until LED L1 starts flashing. Then use the “Open” and “Close” buttons to move the currently selected LED up or down, respectively. You have 10 seconds for each operation; otherwise, the drive will exit programming mode. When the flashing LED is positioned above the LED for the function you want to enable or disable, press the “Stop/Set” button once to make the flashing faster (function enabled) or slower (function disabled), then leave it as is and the drive will exit programming mode within 10 seconds. If everything went correctly, the corresponding LED for the function being enabled will remain lit.
List of programmable functions that can be enabled:
| LED | Function | Description |
|---|---|---|
| L1 | Automatic closing |
After a certain period (set in “Level II programming – Pause duration”), the gate will start closing automatically after it has opened. If this function is disabled, the gate can only be operated by a command from the gate remote control and similar devices. |
| L2 | Close after photocells are cleared |
This function keeps the gate open only for the time needed for a vehicle to pass through. Once the photocells are cleared (the vehicle has passed through), the gate will start closing automatically after 5 seconds. This function operates in two different ways, depending on whether automatic closing is enabled (see the previous function). Automatic closing enabled – the gate stops when the photocells are cleared and starts closing after 5 seconds. This means it may not open all the way. |
| L3 | Motor force |
This function affects the motor’s sensitivity to obstacles. If this function is disabled, the drive is less sensitive, which is suitable for larger and heavier gates.. If your gate is small and lightweight, you can enable this function.. |
| L4 | Standby mode |
This function minimizes power consumption. When this function is active, one minute after the gate’s last movement, the control unit switches off the BlueBUS input (and therefore all devices connected to it) and all LEDs except the BlueBUS LED, which will flash slowly. In this state, if a command is received, the control unit first restarts and only then carries out the command. |
Level II programming
In Level II programming, values are set for the functions (these functions differ from those in Level I.).
Forget Level I programming.. To enter Level II programming, press and hold the “Stop/Set” button for approx. 5 seconds, until LED L1. starts flashing. Then use the “Open” and “Close” buttons to move the currently selected LED up or down, respectively. You have 10 seconds for each operation; otherwise, the drive will exit programming mode. When the flashing LED is positioned above the LED for the function whose parameter you want to set, press and hold the “Stop/Set” button to open the settings for that LED. The LED that remains lit (while you continue holding “Stop/Set”) indicates the current parameter value. You can increase or decrease this value using the “Open” or "Close” button (while continuing to hold “Stop/Set”), then release “Stop/Set” and leave it as is so the drive exits programming mode within 10 seconds. To check that everything went correctly, repeat the procedure without changing the parameter value.
List of programmable functions with adjustable settings:
|
Input LED — Name |
Setting LED — Value |
|---|---|
| L1 — Pause duration If the “Automatic closing” setting is enabled in Level I programming, |
L1 — 10 seconds L2 — 20 seconds L3 — 40 seconds L4 — 80 seconds |
|
Sets the sequence of gate movements triggered by repeatedly pressing, for example, the button on the gate remote control, or by activating the STEP-BY-STEP input (also called P.P.or Step-by-step). |
L1 — Open/Stop/Close/Stop L2 — Open/Stop/Close/Open L3 — Condominium L4 — Hold-to-run |
|
Sets the gate’s travel speed during normal operation (excluding acceleration and deceleration). |
L1 — Very slow (55%) L2 — Slow (70%) L3 — Medium (85%) L4 — Fast (100%) |
|
Sets when a signal should be sent to the FLASH output . |
L1 — Gate open indicator L2 — Warning beacon L3 — Electromechanical lock L4 — Electromagnetic lock |
Connecting additional external devices to the operator
![]() |
If you need to connect additional devices to the operator that require an external power supply (e.g. indicator lighting, key switch, magnetic cards, etc.), connect the device as shown in the diagram. The supplied voltage is 24 V DC, -30% to +50%, with a maximum current of 100 mA. |
Special operator functions
Gate held open
If the command to the STEP-BY-STEP input (also labelled P.P. or Step-by-step) is held for longer than 3 seconds, the control unit will keep the gate open for as long as the command is active. This function is useful when used with a timer.
Forced movement
If a safety device fails, or, for example, an object that cannot be removed gets into the beam of the photocells and the gate will not move for safety reasons, you can activateHold-to-runmode, either permanently in Level II programming by setting L2 - Step-by-step mode to L4 - Hold-to-run, or temporarily:
- Send a command to the gate (using aremote control, key switch , etc.)
- If there is a problem, the gate will not move and the beacon will probably indicate an error.
- Within 3 seconds of the previous command, send the command again and hold it.
- The gate will move while you hold the command and stop when you release it.
Troubleshooting the operator
If anything is unclear or you have any other problem, feel free to contact our technical support team for NICE operators.
Depending on the nature of the problem
During installation (or if the operator fails), you may encounter one of the following problems:
|
Problem |
Possible solution |
|---|---|
|
The gate does not respond to the remote-control command, and the LED on the remote control does not light up. |
Check whether the batteries in the operator remote control are in good condition; if not, replace them. Refer to the manual for the specific remote control for instructions. |
|
The gate does not respond to the remote-control command, but the LED on the remote control lights up. |
Check whether the remote control has been stored in the memory of the receiver correctly, or try remote control storing it again. |
|
The gate does not move and the BlueBUS LED does not flash.
|
Check whether the operator is supplied with 230 V. If it is, test both fuses and, if necessary, replace them with new fuses of the same rating. |
|
The gate does not move and the beacon does not flash. |
Check whether the operator has registered the command at all. When a command is sent using the remote control the BlueBUS LED should flash twice quickly. If the command is sent by another device through the STEP-BY-STEP input (P.P.), the corresponding STEP-BY-STEP LED. |
|
The gate does not move and the beacon flashes several times. |
Count the flashes and see Diagnostics using beacon flashes. |
|
The gate starts moving, but stops immediately and begins moving in the opposite direction. |
The programmed motor force is probably too low for your gate. Check that nothing is obstructing the gate’s movement and increase the operator force if necessary. |
|
The gate starts moving, but the beacon does not work. |
Check whether there is voltage at the FLASH output during gate operation (the voltage level is not important, approx. 10–30 V DC). If there is voltage at the output, the problem is likely with the beacon (or another device); try replacing it with a similar one to see if it works. If there is no voltage at the output, the FLASH output may be overloaded; check whether the wiring has short-circuited. |
Diagnostics using the flashing beacon
During gate operation beacon flashes regularly once every second. If a problem occurs, the beacon signals an error with two faster consecutive sequences of flashes.
|
Flash sequence |
Error |
Solution |
|---|---|---|
|
1 flash 1-second pause 1 flash |
BlueBUS error
|
The devices connected to the BlueBUS input do not match those detected during the device detection phase.. Run the detection phase again. If that does not help, try once more; otherwise, use the process of elimination to find and replace the faulty device (buy a new one, make a warranty claim, or have it repaired). |
|
2 flashes 1-second pause 2 flashes |
Photocell activation |
The photocells are triggered, photocells, which is normal if their beam is interrupted while the gate is closing. If the beam was not interrupted, the photocells may be dirty, dazzled by bright light, or faulty. |
|
3 flashes 1-second pause 3 flashes |
Motor force limiter activated
|
While the gate is moving, increased friction may be detected. The gate may not be adjusted correctly; try moving it by hand and readjusting it. Otherwise, it usually helps to increase the motor force.. |
|
4 flashes 1-second pause 4 flashes |
STOP input activated
|
A command was sent to the STOP input,so if this was unexpected, check the devices connected to it. |
|
5 flashes 1-second pause 5 flashes |
Control unit internal error |
Wait 30 seconds and try again. If the problem persists, try to reset it.. Otherwise, the control unit will probably need to be repaired or replaced. |
|
6 flashes 1-second pause 6 flashes |
The hourly manoeuvre limit has been reached. |
Wait a few minutes for the cycle limiter value to fall below the limit. |
|
7 flashes 1-second pause 7 flashes |
Internal electronic circuit error. |
Disconnect the entire operator for a few seconds, then try again. If the problem persists, try to reset it.. Otherwise, the control unit will probably need to be repaired or replaced. |
Diagnostics using the flashing LEDs
On the SNA2 control unit of the NICE Spinbus SN6021 operator, there are two sets of LEDs. By flashing or staying lit, each set indicates normal control unit operation or diagnoses faults, as shown in the tables below.
Horizontal BLUEBUS, STOP, PP and OPEN LEDs
|
Indicator |
Status |
Solution |
|---|---|---|
|
BlueBUS LED |
||
|
Off |
Error
|
Check the mains power connection;if it is correct, check fuses F1 and F2 and, if necessary, replace them with new fuses of the same rating. |
|
On |
Serious error
|
Try disconnecting the control unit, or all inputs.. If that does not help, reset the unit, and if that still does not help, the control unit will probably need to be replaced. |
|
Flashing at one-second intervals |
All OK |
The control unit is operating normally. |
|
2 quick flashes |
The input status has changed |
Normal operation – an input status has changed STEP-BY-STEP, STOP, the photocells, or the operator received a command from the remote control.. |
|
Flash sequences separated by a one-second pause |
Various possibilities |
The number of flashes in the sequence corresponds to the fault diagnostics indicated by the beacon.. |
|
STOP LED |
||
|
Off |
The STOP input has been activated. |
Check the devices connected to the STOP input.. |
|
On |
All OK |
The STOP input is not active. |
|
STEP-BY-STEP LED (also labelled P.P. or Step) |
||
|
Off |
All OK |
STEP-BY-STEP input is not active. |
|
Lit |
The STEP-BY-STEP input has been activated |
Normal operation of the control unit if an active device is connected to the STEP-BY-STEP input. |
Vertical LEDs L1–L4
|
Signal |
Solution |
|---|---|
|
LED 1 |
|
|
Off |
During normal operation, indicates that the Automatic closing function is disabled. |
|
Lit |
During normal operation, indicates that the Automatic closing function is enabled. |
|
Flashing |
|
|
LED 2 |
|
|
Off |
During normal operation, indicates that the Close after photocell interruption function is disabled. |
|
Lit |
During normal operation, indicates that the Close after photocell interruption function is enabled. |
|
Flashing |
|
|
LED 3 |
|
|
Off |
During normal operation, indicates that the Motor force function is disabled. |
|
Lit |
During normal operation, indicates that the Motor force function is enabled. |
|
Flashing |
|
|
LED 4 |
|
|
Off |
During normal operation, indicates that the Standby mode function is disabled. |
|
Lit |
During normal operation, indicates that the Standby mode function is enabled. |
|
Flashing |
|
Replacing the bulb in the NICE SNA2 control unit for the NICE Spinbus SN6021 operator
Before replacing the bulb, disconnect the operator from the power supply and follow these steps:
| 1. Press the white cover and turn it | 2. Press the old bulb in slightly and turn it a little. Then install a new 12V 21W bulb with a BA15 base. |
|---|---|
|
![]() |
Resetting the control unit
1. Press and hold the first (Open) and the third (Close) button.
2. When all the LEDs light up, release the buttons.
3. Wait for the control unit to reset.
Technical specifications of the NICE SNA2 control unit for the NICE Spinbus SN6021 operator
| Model | NICE SNA2 | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Type description | Control unit for a geared motor NICE Spinbus SN6021 for automatic operation of garage doors in private settings. | ||||||||||
| Backup power supply | Not available. | ||||||||||
| Lighting | 12V 21W bulb, BA15 base | ||||||||||
| Warning light output |
Depending on the programmed output:
|
||||||||||
| BlueBUS output | one output for 2 BlueBUS devices | ||||||||||
| STOP input | for normally open, normally closed and 8.2KΩ constant-resistance devices | ||||||||||
| STEP-BY-STEP input (P.P., step-by-step) | normally open (closing the circuit triggers the “Step-by-step") | ||||||||||
| Radio receiver | without receiver, “SM” connector for receivers NICE SMXI, NICE OXI etc. | ||||||||||
| Antenna input | 52Ω for RG-58 coaxial cable (or similar) | ||||||||||
| Programming functions | 4 on/off functions (Level I programming) 4 adjustable functions (Level II programming) |
||||||||||
| Self-diagnostic functions |
|
||||||||||
| Operating temperature | -20°C to +50°C | ||||||||||
| Use in saline, acidic and potentially explosive environments | no | ||||||||||
| Protection class | IP00 |