Description of NICE S-Fab SFAB2024 – standalone underground operator for a swing gate leaf up to 2.3 m / 400 kg

NICE S-FAB SFAB2024 is a standalone underground operator for one leaf of a residential gate. The motor operates at 24 V DC, without an encoder or control unit. It requires a foundation box NICE SFABBOX and a compatible MC424L control unit. A double-leaf gate requires two motors, two boxes and one control unit.

It is a non-reversible operator with a triangular-key release. The individual limits are 2.3 m and 400 kg; the permitted weight depends on the leaf length, as shown in the table and graph. The motor is designed to be installed in a box at the hinge axis, so no arm is visible on the gate.

Quick navigation
Controls and accessoriesKits and box
Selection and limitsBox installation
90°/180° stopsMotor wiring
Terminals and polarityPhotocells and Phototest
Initial startupProgramming
Remote controlBattery and solar power
ReleaseTroubleshooting
Testing and maintenanceSpecifications and dimensions
PDF manual

Controls and compatible accessories

Accessories connect to the control unit. The standalone motor does not include a radio receiver, photocells or a battery. When selecting, check the board designation, terminals, voltage and radio coding; the listed types are not all universally interchangeable.

What Why Type
Control unit Controls one or two SFAB2024 motors without an encoder. Wiring and programming depend on the board; control unit selection and identification.
Flashing light Indicates movement. The MC424LR30 output is 24 V DC, maximum 25 W. Use a light with a suitable voltage and power consumption; +/− terminals. ELDC has a separate antenna connection.
  • LED flashing light with antenna ELDC
  • Multifunction light WLT

Choose other lights according to the voltage and output limit, not just their appearance.

Photocells Passage protection depends on the selected input and operating mode. The MC424L uses photocells with a relay contact; BlueBUS EPMB photocells cannot be connected here. EPM and Phototest wiring.
  • Wired relay type - EPM
  • Relay type with reflector - EPMOR
  • Wired relay type EPS
  • Wired Antivandal relay type - EPMA
  • Wired relay type EPL
  • Wired relay type - F210
  • Wired/wireless relay type - FT210
Transmitter The transmitter must use coding supported by the receiver actually installed. Matching frequencies alone are not enough. MYGO and ON are suitable when O-Code is supported; FLO/FLOR require a corresponding receiver. ON3ELR is for the OXILR. Selection and pairing.
Receiver The control board includes radio control, depending on its version. IT4WIFI requires a compatible IBT4N interface. A Wi-Fi/GSM module with a volt-free NO contact can send an SbS command; its power supply and current draw must be checked separately.
  • Wi-Fi receivers: IT4WIFI
  • Alternatively, third-party Wi-Fi receiver. We recommend a fully compatible, reliable Wi-Fi receiver Zamel with the simple, convenient SUPLA mobile app (Android/iOS). 

Replacement board MCA2R30 for MC424LR30

Antenna Improves reception when used at the correct frequency and in a suitable location. Connect the coaxial cable to the receiver's antenna terminals; the ELDC antenna is electrically isolated from its power supply.
  •  integrated into the beacon ELDC
  • standalone antenna ABFKIT
Keypad Access code. The EDS requires a compatible decoder, such as MORX; the EDSWG requires a compatible radio receiver. Do not connect the keypad directly to the motor power wires.
Key switch Key-operated control via a volt-free NO contact. Connect to COMMON and SbS according to the terminals on the relevant control board.
  • surface-mounted, with a standard cylinder EKS
  • surface-mounted, with a European cylinder, EKSEU
  • flush-mounted, with a standard cylinder EKSI
  • flush-mounted, with a European cylinder EKSIEU
Card readers Access using a card or fob. The ETP requires a compatible MORX decoder; its output sends a command to the control unit. The reader alone does not replace the decoder.
  • ERA Transponder Reader ETP
Electric locks Additional gate-leaf locking, if required for the specific gate. The lock must be compatible with the 12 V AC / 15 VA output, and its operation must be configured on the control unit. This does not increase the permitted weight or length of the gate leaf.
Backup power supply Automatic operation during a power outage or a suitably sized solar power supply. The connector and Stand-by setting depend on the control unit; battery and solar requirements.

NICE PSS124
NICE CABLA11

SFAB2024 and the correct control unit

SFAB2024 has no encoder and uses the MC424L controller. The current standalone control unit is MC424LR30 with MCA2R30 board. For an assembly with MC424LR10 use the manual for the relevant unit and check the terminal labels and numbering directly on the board. The detailed terminal table below applies exclusively to MC424LR30/MCA2R30; do not use it with different numbering.

SFAB2024 is a 24 V DC motor without an encoder and uses the compatible MC424L control unit. The motor’s 24 V rating does not mean the control unit is mains-powered; the standard MC424LR30 is powered from a 230 V AC mains supply.

Standalone motor, box, and complete kits

The NICE SFABBOX must be purchased separately for the motor. A more cost-effective option may be a motor and box combination or a complete kit. The box is made of steel with a black cataphoretic coating and can be used for either a right- or left-hand gate leaf.

One gate leafMotor and boxTwo gate leaves
Kit for one gate leaf
1 × motor and box
MC424L, remote control, relay photocells, and ELDC

NICE S-FAB SFAB2024 kit for one gate leaf
SFAB2024 + SFABBOX
1 × motor and box
Control unit and safety accessories not included

SFAB2024 motor with SFABBOX foundation box
Kit for two gate leaves
2 × motor and box
MC424L, remote control, relay photocells, and ELDC

NICE S-FAB SFAB2024 kit for two gate leaves

Check the contents of the selected kit for the exact control unit version and included accessories. Two motors do not increase the limit for an individual gate leaf. The motor comes with a power cable measuring 2 m; the motor and box together provide mechanical stops, which must be correctly fitted during installation.

When to choose an underground operator

  • There is no room at the hinge for a linear actuator or articulated arm operator for a wall, fence, or opening gate.
  • You want a clean look for your gate, with no visible arm. The operator remains in a box beneath the hinge.
  • You need an installation for 90° or 180° opening, and there must be enough clear space around the gate.

The operator is designed for residential use. The manufacturer specifies a maximum of 60 cycles per hour under rated conditions; for 180° opening, this figure is halved to 30 cycles/h. The actual load depends on the gate leaf, wind, friction, and settings; a 24 V rating alone does not guarantee suitability for any level of intensive use.

At the rated speed of 1 revolution per minute, a 90° opening takes approximately 15 seconds. This is not a guaranteed opening time for the complete gate: startup, deceleration, load, and control unit settings can affect it.

Gate leaf length and weight limits

The 2.3 m and 400 kg limits do not apply simultaneously. Assess each gate leaf separately. The hinges must be aligned, the gate leaf must move smoothly without sticking, and it must not move on its own in any position.

Length of one gate leafWeight limit shown on the graph
Up to 1.5 m400 kg
1.8 m330 kg
2.0 m300 kg
2.3 m250 kg

NICE S-FAB: permitted combinations of gate leaf length in metres and weight in kilograms

These values are graph limits, not a recommended safety margin. Wind, solid infill, and resistance to movement can reduce the usable weight limit. Choosing an operator for your gate check with us based on its length, weight, infill, and number of cycles.

Installing the foundation box and motor

Before starting work, disconnect the mains supply, battery, and any other power source. Underground installation requires effective box drainage, a solid foundation, and access for release and maintenance. IP67 means protection during temporary immersion; the box must not remain flooded.

Detailed instructions for preparing the foundation are also available in our article Installing the foundation box for an underground operator.

Foundation, drainage, and shared hinge axis

  1. Check the gate’s load-bearing capacity, hinges, free movement, and clearance for the full opening range. Support and secure the gate leaf before dismantling.
  2. Prepare the excavation, cable conduits, and drainpipe. Level the box and set it in concrete according to the drawing, keeping access to the cover clear.
  3. The pivot axis of the lever in the box must align precisely with the axis of the gate leaf’s upper hinge. Misaligned axes cause strain and sticking; increasing the control unit’s force will not solve this.
  4. Secure the load-bearing lever to a structural part of the gate leaf according to the original drawing: three M10 threaded points with an effective depth of at least 15 mm, or use suitable professional welding.
  5. Lubricate the bushing before inserting the lever. Secure the gate leaf against lifting and removal in accordance with the drawing.

S-FAB: levelling the box, drainage, and cable conduit

S-FAB: aligning the upper hinge and lever axes, securing the lever to the gate leaf

S-FAB: lubricating the bushing and securing the gate leaf against lifting

Mechanical stops for 90° or 180° opening

The operator uses mechanical end stops, not electrical limit switches. The installation allows adjustment to approximately 90° ±10° or 180° ±10° according to the two configurations shown in the drawing. The integrated adjustment cannot be used to select an arbitrary angle between these ranges. Fit the required external mechanical stops for the specific assembly; do not rely on motor run time alone.

  1. Choose the stop installation for the relevant 90° or 180° range, as shown in the illustration.
  2. Move the gate leaf manually to its end positions, adjust the stop screws, and tighten the locknuts.
  3. Place the motor in the box and align the mounting holes. First tighten the supplied screws just enough to lift the motor slightly above the bottom of the box.
  4. Move the gate leaf slowly by hand to engage the gear; only then secure the motor fully. Installed parts must not be under strain.
  5. Route the cable through the designated opening, check the covers, and repeat the manual test along the full travel path.

S-FAB: original layout and stop adjustment for 90° and 180°

S-FAB: stop adjustment and inserting the motor into the box

S-FAB: gear engagement during manual movement and cable routing

S-FAB: fitting covers A, B and C after installation is complete

Motor cable and control unit

SFAB2024 wirePurpose
Blue and brownTwo 24 V DC motor wires, connected to the corresponding M1/M2 output on the control unit. Their polarity is reversed when the direction changes; they are not permanently marked + and −.
Yellow-greenProtective earth (PE) conductor to the designated earth point; not the power supply negative.
EncoderThe SFAB2024 does not have an encoder. Connect only the motor wires and protective earth (PE) conductor as shown in the table.

Do not splice the power supply cable inside the foundation box. If an extension is needed, use a protected junction box outside the box; it must be accessible and protected against water. Observe the required cross-section and length specified for the control unit. Do not connect 230 V mains voltage to the motor wires.

For the MC424LR30, use a motor cable 3 × 1.5 mm², maximum 10 m: two motor wires and PE. Extend the supplied 2 m cable only using a suitable junction box outside the box; check the cross-section, protection and total length.

With the MC424LR30, connect one motor to M2. With two motors, connect the leaf that opens first to M2 and the leaf that closes first to M1. Adapt the wiring to the overlap between the leaves and confirm it during setup; check other control boards in their respective manuals.

MC424LR30 / MCA2R30 accessory terminals

The following terminal numbers apply to the MCA2R30 board with terminals 1–13. Check the board and terminal block labels before wiring. Carry out electrical wiring with the power off. Connect voltage-free contacts between the relevant input and the designated COMMON terminal; do not apply an external voltage to the input.

TerminalFunction and polarity
1 / 2 – FLASH1 = −, 2 = +; 24 V DC, maximum 25 W. For NICE ELDC use a separate power pair; connect the antenna to the receiver's antenna terminals.
3 / 4 – OGI3 = −, 4 = +; 24 V DC gate-open indicator, maximum 5 W. When configured for an electric lock, the output is 12 V AC / 15 VA, with no constant +/−; these functions cannot be combined.
5 – OUT STB+; switched 24 V DC supply, maximum 100 mA, depending on Stand-by or Phototest mode.
6 – 0 V−; common negative for the auxiliary power supply.
7 – 24 V+; 24 V DC accessory supply (16–33 V), maximum 200 mA. In Stand-by mode, the supply drops to 21 V DC ±10%, with 2 W of power available. The total current draw must not exceed the applicable limit.
8 – COMMONCommon terminal for contact inputs, +24 V when Stand-by is disabled. It is not the power supply negative.
9 – ALT/STOPSafety input, depending on the setting; NC contact or 8.2 kΩ safety edge. Wiring and setup must match the selected mode.
10 – PHOTO / 11 – PHOTO1NC relay contacts for photocells. The two inputs respond differently; do not jumper them as a substitute for protection.
12 – SbSVoltage-free NO contact for step-by-step control; suitable for a key switch or control-module relay.
13 – AUXConfigurable input. For PHOTO2, this is an NC safety contact; for a control command, follow the selected function.

MC424LR30: original diagram B with terminals 1–13 and photocells powered continuously

EPM relay photocells: standard power supply and Phototest

For NICE EPM both the TX transmitter and RX receiver have terminal 1 = + and terminal 2 = −. On the RX, 4 = COM and 5 = NC; terminal 3 is NO and is not used for the PHOTO safety input. Relay terminals 4–5 are voltage-free contacts and have no +/− of their own.

MCA2R30 modeConnecting EPM to PHOTO
Photocells powered continuously – diagram BTX1 and RX1 → 7 (+); TX2 and RX2 → 6 (−); RX4 COM → 8 COMMON; RX5 NC → 10 PHOTO.
Phototest – pair on PHOTO, diagram C or DTX1 → 5 OUT STB (+); TX2 → 6 (−). RX1 → 7 (+), RX2 → 6 (−), RX4 → 8 COMMON, RX5 → 10 PHOTO. Repeat setup and testing after configuration.
Stand-by with switched power supply – diagram ATX1, RX1 and RX4 COM → 5 OUT STB (+); TX2 and RX2 → 6 (−); RX5 NC → 10 PHOTO. Observe the 100 mA limit for OUT STB.

PHOTO (10) reverses movement during closing; it does not affect movement while opening. PHOTO1 (11) stops movement in both directions. PHOTO2 on AUX (13), if configured this way, reverses movement while opening and does not affect closing. The location and choice of safety devices must match the risks associated with the specific gate.

Stand-by and Phototest are alternative modes. For one pair of photocells on PHOTO in Phototest mode, use diagram D: connect the unused PHOTO1 input (11) to OUT STB (5). Likewise, connect the unused AUX (13) to terminal 5 only if it is configured as PHOTO2. This must not bypass any installed safety device. For multiple pairs, use diagram C. Do not confuse COMMON (8) with switched OUT STB (5).

EPM: original TX and RX terminals, 1+/2− polarity and NC/COM relay

MC424LR30: diagram D for Phototest with one pair on PHOTO and PHOTO1 unused

MC424LR30: circuit C for Phototest with at least two pairs of photocells

MC424LR30: original circuit A for Stand-by mode with switched photocell power supply

Initial startup and travel learning

Before switching on, the motors must be securely mounted and locked, correctly wired, with the stops and safety inputs set. For the MC424LR30, select the XME2024 type on the selector, corresponding to the SFAB2024, as shown in the original row in the image.

MC424LR30: for the SFAB2024, use the bottom row of the selector marked XME2024

  1. After switching on, check the power and safety input LEDs. Resolve any incorrect indications before starting the learning procedure.
  2. Manually release the gate leaves, position them approximately halfway along their travel, and lock them again; for a double-leaf gate, check their sequence.
  3. On the MC424LR30, hold down STOP/SET + CLOSE for more than 3 seconds according to the travel learning procedure. The start-up sequence checks the direction, then the gate leaves close, open, and close fully.
  4. If the movement is in the wrong direction or the gate leaves overlap incorrectly, stop the learning procedure immediately. After disconnecting all power sources, correct the wiring and repeat the entire procedure.
  5. Once learning is complete, test a full cycle, slowdown, STOP, photocells, and other safety devices. Repeat the test after changing the wiring or any relevant settings.

Control unit programming

The motor has no adjustment buttons of its own. Automatic closing, pause time, speed, force, gate-leaf delay, Stand-by, and the AUX/OGI function are set on the relevant control unit. The MC424LR30 has two programming levels with eight LEDs; procedures for other generations should not be applied automatically.

MC424LR30 operationWhere to find the procedure
Buttons, input, and savingControl buttons and programming
ON/OFF functionsLevel I – functions and default states
Parameters and rangesLevel II – values for each LED
Deletion or resetReset procedure for the specific control board; clearing the radio memory is a separate operation.

Do not increase the force setting as a substitute for repairing a gate that is binding. Any change that affects movement or safety inputs requires the functional and safety tests to be repeated.

Selecting and pairing remote controls

Before buying a remote control, check the receiver type and coding in the control unit. For a currently compatible model, a common choice is NICE MYGO4. Instructions for storing button commands and clearing the memory are in the MC424LR30 radio control. Learning a transmitter does not replace learning the motors. Do not choose older FLO/FLOR models or a remote control for a different radio interface based solely on the 433.92 MHz frequency.

Backup battery and solar power

Without a backup power source, use the manual key release. For the current MC424LR30, select the NICE PSS124 with the appropriate connector. The older NICE PS124 requires a NICE R30 adapter NICE CABLA11 and Stand-by disabled. For a different control unit, check the connector and the power source requirements; do not connect the battery directly to the motor.

NICE SOLEMYO SYKCE30 is an alternative, subject to an assessment of daily power consumption and sunlight conditions. For solar power, enable Stand-by and connect the accessories according to their operating mode. Do not connect mains power and SOLEMYO at the same time. The setup differs from using the PS124 via the CABLA11.

Manual release during a power failure

  1. Stop the gate and hold the gate leaf to prevent it from moving on its own. Release the gate only when the leaf is stationary.
  2. Insert the triangular key into one of the side release holes and turn it 180° in either direction. The gate leaf can now be opened or closed manually.
  3. To re-engage the mechanism, turn the key 180°. The mechanism engages during the first movement initiated by a command; keep the gate area clear during testing.
  4. For a double-leaf gate, repeat the procedure on the second motor. Once power is restored, check automatic operation and the safety devices.

S-FAB: release using the triangular key inserted into the side opening

Troubleshooting checks

SymptomProcedure
Motor does not runCheck the control unit's power supply and safety inputs, that the motor is engaged, the M1/M2 output, and the cable. Do not test by connecting directly to 230 V.
Gate leaf bindsCheck manual movement, alignment of the hinge and arm, gate-leaf security, correct engagement of the drive, and the stops. Do not try to fix this by increasing the force.
Wrong direction or sequenceStop the movement, disconnect the power sources, check the motor wires and M1/M2, then repeat the learning procedure.
Learning or Phototest failsCheck the STOP/PHOTO/PHOTO1 indicators, TX/RX polarity, and the difference between COMMON and OUT STB. The wiring must match the Stand-by and Phototest settings.
Button works, remote control does notCheck the transmitter battery, supported coding, and radio memory according to the pairing procedure.
Water in the enclosureCheck drainage, a blocked drain, and the tightness of connections outside the enclosure. Switch off the power and arrange a repair; IP67 does not eliminate the need for a functioning drain.

Safety testing and maintenance

Before handover, test the manual release, full opening and closing, stops, gate-leaf sequence, and all safety devices. Check that the forces are safe and that the required safety devices are installed throughout the system; the motor's maximum torque is not a safe contact force for a person. Children must not play with the controls or near a moving gate.

Arrange an inspection at least every 6 months. After disconnecting all power sources, clean the enclosure and drain; check for corrosion, tightness of screws and stops, the housing, hinges, cable, and anti-lift protection. Apply any required lubrication in accordance with the installation procedure. Repeat the movement and safety tests after maintenance. Repair damaged parts and electrical wiring before using the system again.

Estimated service life for a 1.51–2.3 m gate leaf

For gate leaves 1.51–2.3 m long, you can use the following indices. Estimated service life depends on the weight and length of the gate leaf, the environment, and its infill. Read the sum of the indices on the horizontal axis of the original graph; the vertical axis shows the number of cycles. This is an estimate assuming regular maintenance, not a guarantee or a number of years. For a borderline configuration, first consult the suitability chart.

Characteristics of the complete automation systemIndexService life graph
Gate leaf weight1.51–1.8 m1.81–2.0 m2.01–2.3 m

S-FAB: approximate number of cycles based on the sum of load indices, as a percentage

Up to 100 kg10%20%30%
101–250 kg20%30%40%
251–300 kg30%40%50%
301–330 kg40%50%—
331–400 kg50%——

Add to the base index 15% at temperatures above 40 °C or below 0 °C, or humidity above 80%; an additional 15% for a solid infill and 15% when installed in a windy environment. Each relevant factor is counted separately. A dash in the table does not mean zero load; check suitability against the limit graph.

Solid infill, wind, high humidity and temperature conditions reduce service life. Therefore, when planning operation, also take the environment and actual resistance to movement into account, not just the maximum weight.

SFAB2024 technical specifications

ParameterValue
DesignNon-reversible underground motor without encoder, with sealed metal housing
Motor power supply24 V DC from the MC424L control unit
Individual gate leaf limits2.3 m / 400 kg; combination according to the application graph
Maximum current / power consumption5 A / 120 W
Maximum torque250 Nm
Speed under no load1.25 rpm
DutyResidential; up to 60 cycles/hour under rated conditions, half that at 180°
Mechanical angle adjustment90° ±10° or 180° ±10°, depending on the installation of the stops
Ingress protection ratingIP67 – temporary immersion; box drainage is required
Operating temperature−20 to +50 °C
Motor dimensions only235 × 206 × 96.5 mm
Motor weight only6 kg
Power cable2 m
Foundation boxSFABBOX, sold separately or as part of a combination/kit

The dimensions and weight of the motor differ from those of the complete box with lever. The box drawing below shows a 320 × 255 mm plan view and the vertical dimensions for its installation; all dimensions in the drawing are in millimetres. Allow for drainage and a cable conduit in the foundation.

S-FAB SFABBOX: original dimension drawing of the foundation box and lever in mm

360° drive view

The SFAB2024 drive was previously also known as X-FAB XFAB2024 and X-METRO XME2024. Always verify the actual motor model and control unit board when wiring.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE S-Fab SFAB2024 – standalone underground operator for a swing gate leaf up to 2.3 m / 400 kg

Product: NICE S-Fab SFAB2024 – standalone underground operator for a swing gate leaf up to 2.3 m / 400 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.