NICE Run RUN2500P - standalone drive for sliding gates
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€875.80 including VAT
| Weight |
|---|
| 25 kg |
Description of NICE Run RUN2500P - standalone drive for sliding gates
NICE RUN2500P – sliding gate operator
NICE RUN2500P is a standalone non-reversible electromechanical operator with built-in control unit RUA1. Both the motor and mains supply are 230 V AC. It has an inductive, non-contact limit switch.
For one gate leaf weighing up to 2,500 kg and measuring 18 m; suitability also depends on movement resistance and frequency of use. The standalone operator does not include a receiver, remote control, photocells or rack. The cover is impact-resistant; the body is made of aluminium alloy with an epoxy coating.
| Quick navigation | ||
|---|---|---|
| Kits | Accessories | Selection and limits |
| Installation | Limit switches | Wiring |
| 24 V polarity | First startup | Programming |
| Faults | Manual release | Specifications |
| Maintenance | Two operators | PDF manual |
Standalone operator or kit
The letter at the end of the kit designation identifies the equipment included. The motor model remains RUN2500P; P denotes an inductive limit switch, not a more powerful motor.
| Kit with accessories | Standalone operator | Kit with rack |
|---|---|---|
1 × RUN2500P with RUA1, 1 × OXIBD, 1 × FLO2RE. 1 pair EPMB. 1 × ELDC. | Inductive limit switch. | 1 × RUN2500P with RUA1, 1 × OXIBD, 1 × FLO2RE. 1 pair EPMB. 1 × ELDC. Plus 4 m of rack LZ-1. |
| Another kit | Equipment differences |
|---|---|
| NICE RUN2500PB | Motor and RUA1, OXIBD receiver and 1 remote control; no photocells, warning light or rack included. |
| NICE RUN2500PC | Equipment B + 1 pair of EPMB photocells; no warning light or rack included. |
| NICE RUN2500PE | Equipment C + 4 m of LZ-1 rack; no warning light included. |
The rack included in the kit is not automatically suitable for the full 2,500 kg maximum load. For a heavy gate, choose the load capacity and material according to the rack selection; agree any changes to the equipment before placing your order. Four metres of rack will cover only the corresponding length of the track.
Accessories for RUN2500P
Select the required equipment below according to your gate and the receiver actually installed. The built-in RUA1 does not replace a radio receiver or safety devices.
| What | Why | Type |
|---|---|---|
| Warning light | Alerts you to movement and signals faults. Connects to FLASH; the antenna has a separate coaxial cable. | |
| Photocells | Detect an obstruction in the beam; the response is determined by the pair address. They do not replace protection at all hazardous points of the gate. |
BlueBUS wiring; FT210B for a moving safety edge. The TX and RX of one pair have the same address. |
| Transmitter | Choose according to the coding and type of receiver installed. The same frequency alone does not confirm compatibility; LoRa and bidirectional functions require a compatible receiver. | |
| Receiver | The radio receiver plugs into the SM connector; pairing depends on the receiver. Wi-Fi/GSM requires a supported interface or a volt-free P.P. contact. |
|
| Antenna | For improved remote-control range. | |
| Keypad | EDSWG requires a compatible radio receiver. For EDSB, the specific RUA1 version must support BlueBUS control devices; the bus itself does not establish compatibility. | |
| Key switch | For operating the gate with a key via a switch wired to the drive from any location. Dry contact on P.P.; power the lighting separately according to polarity and current draw. | |
| Card readers | Use ETPB only after confirming that the installed RUA1 supports BlueBUS control devices. A reader with a dry-contact relay connects to P.P. and is powered separately according to its current draw. |
|
| Toothing | Required module 4 rack. Choose the material, fastening method and load capacity for the complete gate leaf; a nylon rack is not automatically suitable for the maximum weight of 2,500 kg. |
|
Power outage | The motor is powered from a 230 V mains supply. Neither PS124 nor Solemyo is a direct backup power source for this drive. Use the manual release during a power outage. |
What the drive can do
BlueBUS connects compatible photocells using a two-core cable; supported safety device addresses and the limit of 15 load units are listed in the photocell wiring instructions. Adjustable force, obstacle sensitivity, automatic closing delay and slowdown are listed in the programming tables.
Thermal protection prevents the motor from overheating and reduces the permitted number of cycles at high temperatures. Faults are indicated by the warning light and LED. Wiring Master/Slave allows two opposing sliding gate leaves to be synchronised.
The pinion uses module 4; the rack must be suitable for the gate's weight and construction. Safety must be assessed on the complete, finished gate, including protection of hazardous areas and impact forces. The gate must have secure end stops and protection against coming off its track.
Choosing the NICE RUN2500P drive
The deciding factors are the weight and length of the entire moving gate leaf, including its infill and counterweight, not just the clear opening width. Check that the gate moves freely by hand along its entire travel. The force required to start moving it must be less than 695 N and the force required to keep it moving must be less than 415 N; these are half the peak and nominal force values. Allow for winter conditions, ice and any other increase in resistance.
| Parameter | Manufacturer's maximum | Our indicative recommendation |
|---|---|---|
| Gate leaf weight | 2,500 kg | Up to 2,000 kg |
| Gate leaf length | 18 m | Approximately up to 14.4 m |
A recommended margin of approximately 20% helps with typical product selection. This does not confirm suitability for every gate of this kind; the mechanics, actual forces and required operating frequency must still be checked.
Maximum number of cycles
One cycle consists of a complete opening and closing. First choose the row according to the length; multiply both figures by the weight factor and round down the result. Difficult movement and high temperatures may further reduce the available number.
| Gate leaf length | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|
| Up to 6 m | 42 | 42 |
| Over 6 up to 9 m | 28 | 28 |
| Over 9 up to 12 m | 21 | 21 |
| Over 12 up to 15 m | 17 | 17 |
| Over 15 up to 18 m | 14 | 14 |
| Gate leaf weight | Available cycle ratio |
|---|---|
| Up to 500 kg | 100% |
| Over 500 up to 900 kg | 80% |
| Over 900 up to 1,200 kg | 75% |
| Over 1,200 up to 1,500 kg | 60% |
| Over 1,500 up to 1,800 kg | 50% |
| Over 1,800 up to less than 2,000 kg | No coefficient is specified; individual confirmation of operation is required. |
| 2,000 to 2,300 kg | 40% |
| Over 2,300 up to 2,500 kg | 30% |
For a gate leaf of 16 m / 2,400 kg the calculation is 14 × 0.30 = 4.2: for planning purposes, no more than 4 cycles/hour and 4 consecutive cycles, before any further temperature-related reduction. Thirty percent means the available proportion, not a 30% deduction. For weights between 1,800 and 2,000 kg, the coefficient cannot be inferred from the adjacent rows.
Estimated service life
Add the indices for weight, length and other factors that are likely to occur during more than 10% of operation. Use the total in the chart. The cycle count is an estimate only, not a guarantee or a fixed number of years.
Example: 2,400 kg / 16 m: 60% + 35% = 95% before taking any other factors into account. Frequent photocell interruptions add 10%, giving a total of 105%: this is outside the acceptable range. The mere presence of photocells does not mean that an index is automatically added. Do not use the drive in acidic, salty or explosive atmospheres; the salinity index does not permit such use.
Installing the NICE RUN2500P drive
Anchor the drive to a solid, level base away from areas that may flood. Set the height according to the actual position of the rack and pinion. A cantilever gate may require a higher base or a suitable rigid mounting bracket; its construction must safely withstand the load. The gate must not transfer its weight to the motor.
Cabling
Route the mains supply separately from low-voltage and signal cables. Select accessories, wiring and protection according to the specific installation. Original typical configuration:
|
|
| Purpose | Cable | Max. length |
|---|---|---|
| A – mains | 3 × 1.5 mm² | 30 m; over 30 m, at least 3 × 2.5 mm², subject to assessment of voltage drop and protection |
| B – warning light | 2 × 0.5 mm² | 20 m |
| B – antenna | RG58 coaxial cable | 20 m; under 5 m recommended |
| C – BlueBUS | 2 × 0.5 mm² | 30 m; 2 × 1 mm² for 30–50 m |
| D – key switch | 2 cables, 2 × 0.5 mm² each, or 4 × 0.5 mm² | 50 m |
| E – fixed safety edges | 2 × 0.5 mm² | 20 m |
| F – moving safety edge | 2 × 0.5 mm² | 30 m; moving cable or FT210B |
Installing and checking the foundation
- Before installation, release the drive and check that the gate moves smoothly by hand, the guide is secure, the mechanical end stops are firmly fixed, and the gate leaf is protected against lifting off its track.
- Prepare the cable conduits and the foundation plate with four anchors. Leave no more than 40 mm of thread exposed above the plate.
- Level the plate, set it into a solid foundation, and allow the concrete to cure properly. Do not install the motor on a soft or unstable base.
- Secure the motor with four nuts and washers, adjust its position relative to the rack, then tighten the fixings.
- Along the entire travel path, check the clearance, rack joints, gate guidance, and switch positions. Secure the cables so they cannot come loose and reach moving parts.
Rack and end positions
The gate moves by transferring the drive pinion’s torque into linear motion via the rack-and-pinion mechanism on the drive rack. There are two commonly used types of rack:
![]() |
Nylon rack (optionally with steel reinforcement) – attached to the gate with self-tapping screws through the holes. Ideal for relatively light and short gates. The friction between the steel pinion and nylon rack ensures quiet operation. |
![]() |
Steel rack – attached to the gate by welding on threaded brackets, which the rack is then screwed into. Used for longer and heavier gates. Friction between the steel pinion and steel rack makes operation slightly noisier. |
The key requirement is that the drive pinion module is compatible with the rack module. The NICE Run RUN2500P has a tooth module of 4.
The drive detects the end position during opening and closing using limit switch brackets mounted on the rack:
| 1. Level the drive using the four adjustment points | 2. The gate and drive must both be level | 3. Leave a gap of approximately 1–2 mm between the rack and the drive pinion so the weight of the gate is not transferred to the drive. |
![]() |
![]() |
![]() |
| 4. Tighten the drive anchorage so the drive cannot shift when engaged | 5. Set the limit switch brackets according to the instructions below. Fixed mechanical stops must remain at both ends of the travel path. |
|
![]() |
![]() |
Gap 1–2 mm must be maintained along the entire travel path. Align the rack with the pinion; move the gate manually to check for lateral deviations of no more than 5 mm and smooth transitions between rack sections. Tighten the motor securely once adjusted.
Setting the limit switches
The RUN2500P uses an inductive sensor. The rack-mounted bracket is detected without mechanically pressing a lever. Set the distance between the bracket and sensor to 3–8 mm as shown in the original drawing.
- Move the gate leaf manually to the open position, at least 2–3 cm before the fixed stop.
- Slide the bracket along the rack in the opening direction until the relevant limit switch LED goes out.
- Move the bracket at least another 2 cm in the same direction and secure it.
- Set the closed position in the same way, and check for a 3–8 mm gap throughout the bracket’s full travel.
- After engaging the gearbox and programming the travel limits, check that the gate stops before both mechanical stops.
Wiring the NICE RUN2500P drive
Disconnect the mains supply and verify that the circuit is de-energized before opening, wiring, or disconnecting the terminals. The mains supply is 230 V AC; accessory terminals have different voltages and functions.
230 V AC mains supply
The mains circuit must have suitable overcurrent and residual-current protection and a reliable PE connection. Use an isolating device in accordance with installation regulations; if it is not located near the drive, it must be capable of being locked off to prevent accidental switching on.
| Terminal | Conductor and function |
|---|---|
| L | Live conductor; usually brown. |
| N | Neutral conductor; usually blue. |
| PE / protective earth | Green-and-yellow protective conductor. Class I requires reliable protective earthing. |
Route the mains cable through the smaller grommet and the other cables through the larger one. Fit the membranes snugly around the cables, restore the seal and secure the wiring against pull-out. Leave the required slack inside, approximately 20–30 cm; cables must not obstruct the cover or moving parts.
RUA1 control unit terminals
| Terminal | Function, voltage and polarity |
|---|---|
| FLASH – warning light | ELDC connect using two wires to FLASH, as shown in the warning-light terminal detail. The output is for a low-voltage warning light; its load limit is suitable for one or two warning lights, each with a 12 V / 21 W bulb. It is not a continuous power supply for accessories. WLT has its own setting. Observe any +/− markings on the actual warning light and board; do not assume the polarity of the auxiliary output. |
| S.C.A. – indicator | 24 V DC, max. 4 W, voltage −30% / +50%. Function according to II/L4. For polarized accessories, check the +/− terminals on the specific board; their order cannot be determined from the diagram below. |
| BLUEBUS | Power supply and communication for compatible devices. Photocells connect without polarity. Total limit: 15 BlueBUS load units. For two Master/Slave motors the wire order must be followed exactly. |
| STOP | Potential-free NO, NC or 8.2 kΩ resistive devices; RUA1 learns the device type. A change in the learned state stops movement and briefly reverses direction. The contacts have no +/− polarity and must not be connected to an external voltage source. |
| P.P. / STEP-BY-STEP | Potential-free NO contact for step-by-step control. Connect the module relay's COM and NO contacts to the two P.P. terminals; the contact has no polarity. The module's power supply requires separate wiring. |
| OPEN | Potential-free NO contact for opening; no polarity. |
| CLOSE | Potential-free NO contact for closing; with I/L7 ON, it partially opens. No polarity. |
| AERIAL / antenna | Connect the coaxial cable's core and shield according to the receiver/board terminal markings. These are not power supply +/− terminals. RG58, 52 Ω input; choose an antenna to match the receiver frequency. |
Multiple devices on STOP
Wire NO contacts in parallel and NC contacts in series. Two 8.2 kΩ resistive devices can be wired in parallel; for more devices, use a configuration with a single 8.2 kΩ end-of-line resistor, as shown in the device diagram. Combining NO and NC requires an 8.2 kΩ resistor in series with the NC branch. Do not replace a safety edge with a simple jumper. After making a change, repeat the learning procedure and the safety test.
Fuses
Check only after disconnecting the mains. Replace fuses F1/F2 with the same type, time characteristic and rating specified on the installed board. If a fuse blows repeatedly, find the cause; do not install a higher-rated fuse.
RUA1 wiring with ELDC, EPMB and EKS
The terminals along the top edge of RUA1 are, from left to right, FLASH, S.C.A., BLUEBUS, STOP, P.P., OPEN and CLOSE, with the board oriented as shown in the image. The antenna has a separate connector.
Accessory illustrations are schematic; check the terminals against the markings on the supplied product. EKS here controls OPEN and CLOSE using two contacts C (common contact) + NO (normally open). For step-by-step control, connect the selected C + NO contact pair to the P.P. terminals. Potential-free contacts have no polarity; do not connect them to an external power supply.
The diagram shows the default CLOSE – closing function. If you enable the L7 function in level I, this input will control partial opening instead of closing.
ELDC warning light and its antenna
Connect both output wires from FLASH on RUA1 to the pair of ELDC terminals marked with the bulb symbol. ELDC is a low-voltage LED warning light for 12–36 V DC; do not connect 230 V mains power to these terminals. The light and antenna terminals are separate. The FLASH output flashes and also transmits diagnostic sequences.
With the ELDC detail oriented as shown, the pair of FLASH terminals is on the left and the pair for the antenna is on the right. In the antenna pair, the left terminal is for the coaxial cable's core and the right for its shield. Connect the other end of the coaxial cable according to the symbols on the RUA1 antenna input or according to the antenna wiring for OXIBD, if you are using its input. The shield must not be shorted to the core.
The light power terminals are not marked +/− in this detail. If the supplied version of the warning light or board is marked for polarity, observe it; the pole order of the auxiliary 24 V supply does not apply to FLASH. Use 2 × 0.5 mm² cable for the light and a separate RG58 cable for the antenna, as specified in the wiring table.
EPMB photocells and BlueBUS
NICE EPMB connect to the pair of BLUEBUS terminals on RUA1, with no +/− polarity. Both wires carry power and communication; they must not be connected to the auxiliary 24 V output. TX is the transmitter and RX is the receiver. TX and RX in one pair must have the same address; the next pair must have a different address. The control unit supports a limit of 15 BlueBUS load units; the number of units is not automatically the same as the number of pairs. How the BlueBUS system works.
Parallel connection of one or more pairs
Mount the photocells opposite each other and align their optical axes. When using multiple pairs, also observe the TX/RX orientation, so they do not interfere with each other. After adding or removing a device, perform device learning and test all safety beams.
Photocell positioning for a sliding gate
The diagram shows possible positions, not equipment that is required for every gate. Select the function of each safety pair using the RUA1 address table. FT A / FT B refer to separate optical devices for the moving edge, not to another standard EPMB pair.
For EPMB safety wiring, do not interrupt connection A on TX or RX. The FA1/FA2 addresses shown in the diagram are control functions that trigger opening; they are not among the seven RUA1 safety addresses in the table below. Use them only if support for the specific control unit has been confirmed.
EPMB photocell addresses and jumpers
Set the jumpers with the power disconnected, and set TX and RX identically. Store any unused jumper in the designated place on the photocell. There must not be two pairs with the same address on one network. The diagrams show the jumper configuration, not the power-supply polarity.
When replacing a photocell, retain its correct address and check that it is recognised and responds safely. Repeat the learning procedure whenever the number or addresses of devices change. During testing, interrupt the beam while opening and closing, and verify that the response matches the selected function.
Moving safety edge and FT210B
NICE FT210B transmits the status of an 8.2 kΩ resistive safety edge via an optical beam. The TX on the gate leaf is powered by its own battery; the RX is connected to BlueBUS with no polarity. Set the edge address and wiring according to the FT210B instructions; this is not a standard pair with a wired power supply to TX. The RX current draw counts towards the BlueBUS load.
Radio receiver for operators
For a new setup, you can choose NICE OXIBD for the SM connector. For an existing setup, choose transmitters to suit the SMXI/OXI receiver actually installed. Insert the receiver with the mains power disconnected; store transmitters according to the remote control pairing instructions and the specific receiver. Radio memory, travel learning, and RUA1 settings are separate functions.
![]() |
NICE Run RUN2500P operator is supplied with the NICE RUA1 control unit, which provides an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is required to receive commands transmitted by remote controls, and is therefore essential for operating the sliding gate remotely using a remote control. |
Selecting the gate travel direction
The sliding gate travel direction must be selected with regard to the position of the operator relative to the sliding gate leaf. View the gate from the side where the operator is installed.
![]() |
![]() |
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
The switch is located on the right-hand side RUA1 control unit in the middle.
Initial power-up and device learning
Leave the gate leaf approximately halfway along the track, engage the gearbox, and check the direction setting, limit switches, and that the track is clear. Switch on the power. BLUEBUS should flash approximately once per second, the photocell TX/RX indicators should show activity, and FLASH/S.C.A. should be off when the closed gate is stationary, depending on the selected mode. If the status is incorrect, disconnect the power and fix the fault first.
- Press and hold OPEN + STOP/SET for approximately 3 seconds.
- Release when L1 and L2 start flashing rapidly.
- Wait for BlueBUS and the STOP input detection to finish. L1/L2 will stop indicating that learning is required, and the STOP LED must be lit; L3/L4 may continue flashing because the travel path has not yet been learned.
- After adding or removing a device, repeat the learning procedure and test its safety function again.
Learning the travel length
- After successful device learning, press and hold CLOSE + STOP/SET for approximately 3 seconds.
- Release when movement begins. The first movement must be opening..
- If the gate closes, stop it with STOP, disconnect the power, correct the direction setting, and repeat the learning procedure.
- Allow it to open to the limit switch and then close fully to the second limit switch. Do not obstruct the travel path during learning.
- Check the end positions, partial opening, and several complete cycles.
Testing and handover of the gate
Check movement in both directions, the mounting of the operator and rack, the limit switches and mechanical stops, and each safety device individually. Test the photocells during opening, closing, and while stationary, as applicable to their function. Impact forces must be measured; repeat the test after changing the force, sensitivity, or start-up settings. Do not put the gate into service if its safety protection is not working. The user must be given the keys and instructions, and shown how to manually release the operator and carry out maintenance.
Programming the gate operator
The RUA1 board has OPEN, STOP/SET, and CLOSE buttons, and eight LEDs, L1–L8. The gate must be stationary before making changes. After changing the safety settings, test the complete gate system.
| Button | Normal operation / programming |
|---|---|
| OPEN ▲ | Open / move to the next LED. |
| STOP/SET | Stop / enter settings and confirm. |
| CLOSE ▼ | Close / move to the previous LED. |
Level I – switching functions on and off
- Press and hold STOP/SET until L1 starts flashing, approximately 3 seconds; release the button.
- Use OPEN/CLOSE to select the function LED.
- Press SET briefly to toggle ON/OFF. In programming mode, a short flash means OFF and a long flash means ON.
- Set the next function in the same way, or wait 10 seconds without pressing any button. The settings are saved and programming mode ends.
| LED – function and meaning | Status |
|---|---|
| L1 – Automatic closing After opening, the gate closes after the pause set under II/L1. The factory-set pause is 30 seconds. When OFF, it waits for a command. | OFF – factory setting ON – function enabled |
| L2 – Close after photocell activation After the passage is clear, the gate closes after 5 seconds. With I/L1 OFF, the gate opens fully first; with I/L1 ON, opening stops once the photocells are clear. A STOP command cancels this function for the current movement. | OFF – factory setting ON – function enabled |
| L3 – Always close After power is restored, an open gate closes; the warning beacon flashes for 5 seconds before movement. When OFF, the gate remains stationary after power is restored. | OFF – factory setting ON – function enabled |
| L4 – Slowdown At the end of opening and closing, the speed is approximately 60% of the nominal speed. Available torque is halved; slowdown may not be suitable for a heavy gate or one with high resistance. | OFF – factory setting ON – function enabled |
| L5 – Boost When ON, soft start is disabled and maximum starting force is used. This does not replace fixing friction, track problems, or a frozen gate. After changing the setting, check that the forces are safe. | OFF – factory setting ON – function enabled |
| L6 – Pre-flashing The warning beacon signals for 3 seconds before movement. When OFF, it starts flashing only when movement begins. | OFF – factory setting ON – function enabled |
| L7 – CLOSE = partial opening A CLOSE command from the terminals or remote control initiates partial opening, as set under II/L6. When OFF, it means closing. | OFF – factory setting ON – function enabled |
| L8 – Slave unit Enable only on the second motor in a Master/Slave configuration. When OFF, the gate operator is the Master. | OFF – factory setting ON – function enabled |
Outside programming mode, the LED for a given function is lit when ON and unlit when OFF. Simultaneous flashing of L1/L2 or L3/L4 may indicate that device or travel-path learning is required; see LED diagnostics.
Level II – adjustable values
- Press and hold SET until L1 starts flashing, approximately 3 seconds; release.
- Use OPEN/CLOSE to select the parameter's input LED.
- Press SET again and hold it while adjusting. After approximately 3 seconds, the LED for the current value lights up.
- While continuing to hold SET, select a value using OPEN/CLOSE. Then release SET.
- Repeat the procedure for the next parameter; to exit, wait 10 seconds without pressing any buttons.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause duration Automatic closing time when I/L1 is enabled. | L1 – 5 s L2 – 15 s L3 – 30 s (factory setting) L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – Step-by-step mode Sequence of commands on the P.P. input and the corresponding radio channel. | L1 – Open → stop → close → stop L2 – Open → stop → close → open (factory setting) L3 – Open → close → open → close L4 – Shared entrance: while opening, further commands are ignored; while closing, the gate reopens L5 – Shared entrance 2: as for L4; a command lasting longer than 2 s stops the gate L6 – Step-by-step 2: a short command of up to 2 s triggers partial opening L7 – Hold-to-run: movement continues while the command is held L8 – Semi-automatic opening; closing while the command is held |
| L3 – Obstacle sensitivity Higher sensitivity responds to less resistance. First set the motor force at II/L5, then adjust sensitivity; measure impact forces after making changes. | L1 – Very high – lightweight gates L2 – Very high L3 – High L4 – Medium L5 – Medium-low (factory setting) L6 – Low L7 – Very low L8 – Very low – heavy gates |
| L4 – S.C.A. output 24 V output function / max. 4 W. The choice of radio channels also depends on the receiver. | L1 – Gate-open indicator: off when closed, on when open; flashes slowly while opening and quickly while closing (factory setting) L2 – Active when the gate is closed L3 – Active when the gate is open L4 – Radio output 2 L5 – Radio output 3 L6 – Radio output 4 L7 – Maintenance indicator L8 – Electric lock |
| L5 – Motor force Torque control. The force setting is not determined solely by the gate's weight; do not use excessive force to overcome a mechanical fault. | L1 – 40% L2 – 50% L3 – 60% L4 – 80% L5 – 100% L6 – Semi-automatic 40–100% L7 – Semi-automatic 60–100% L8 – Automatic 0–100% (factory setting) |
| L6 – Partial opening Pedestrian opening distance. It must fit within the gate's actual travel distance. | L1 – 0.5 m L2 – 1.0 m (factory setting) L3 – 1.5 m L4 – 2.0 m L5 – 2.5 m L6 – 3.0 m L7 – 3.4 m L8 – 4.0 m |
| L7 – Maintenance reminder Number of operations since servicing. Opening and closing count as two operations; one complete cycle consists of one opening and one closing operation. | L1 – Automatic, based on the effort required to move the gate (factory setting) L2 – 2,000 operations L3 – 4,000 operations L4 – 7,000 operations L5 – 10,000 operations L6 – 15,000 operations L7 – 20,000 operations L8 – 30,000 operations |
| L8 – Error log Records of the last eight operations; this is not a configurable default setting. | L1 – Most recent operation L2 – Second most recent operation L3 – Third most recent operation L4 – Fourth most recent operation L5 – Fifth most recent operation L6 – Sixth most recent operation L7 – Seventh most recent operation L8 – Eighth most recent operation |
Two sliding gate leaves – Master/Slave
Each gate leaf has its own RUN operator and its own 230 V AC mains supply. One motor is the Master and the other is the Slave. Using two motors does not increase the weight or length limit for an individual gate leaf.
BlueBUS connection
Maintain the wiring order between the motors: Master terminal 1 → Slave terminal 1 and Master terminal 2 → Slave terminal 2. With the same orientation as in the RUA1 terminal diagram diagram, terminal 1 is the left terminal and terminal 2 is the right terminal of the BLUEBUS pair. The numbers 1/2 indicate these positions, not the power supply +/−. The BlueBUS pair does not require polarity when connecting EPMB photocells.
- Set the opening directions for both opposing gate leaves and wire them according to the diagram with the power disconnected.
- Connect the receiver and shared safety/control devices to the Master.
- Switch on both motors. On the Slave, set level I, L8 = ON.
- Run device learning on the Slave first, then on the Master.
- Start travel learning on the Master, then check that both leaves move together and that all safety devices work.
FLASH, S.C.A., the STOP safety edge and P.P. can be connected separately to the Slave. A P.P. command to the Slave opens only its own gate leaf fully; OPEN/CLOSE are not used on the Slave. The Master controls most settings. Sensitivity, force, S.C.A. output, Peak and the error log are also assessed for the specific second drive.
Power supply for external accessories
The auxiliary power available from the RUA1 is 24 V DC, −30% / +50%, maximum 100 mA total. For a nominal 24 V, this corresponds to approximately 16.8–36 V; the connected module must tolerate this range. The power supply and command contact use two separate pairs of wires.
| Purpose | RUA1 terminal | Accessory terminal |
|---|---|---|
| Power supply negative − | Right-hand STOP terminal in the orientation shown in the image below | − / GND for the device power supply |
| Power supply positive + | Left-hand P.P. terminal in the same orientation | + / V+ for the device power supply |
| Step-by-step command | Both P.P. terminals | Voltage-free relay COM and NO; no polarity |
If the current draw is higher, the voltage range is unsuitable or there are startup current surges, use a separate power supply suitable for the module and connect only an isolated voltage-free contact to P.P. Do not use the FLASH or BlueBUS output as a substitute for the auxiliary power supply.
Gate held open and timer
A voltage-free P.P. command lasting longer than 2 s opens the gate and keeps it open for as long as the command is active, for example when triggered by a time switch. This function is not used in mode II/L2, setting L5 “Shared entrance 2”. If an unexpected continuous command occurs, check the timer and the relevant input.
Emergency operation if a safety device fails
Only under direct supervision and with the safety path completely clear: if the first command is rejected due to a safety fault, issue it again within 3 seconds and keep holding it. After about 2 seconds, the gate moves while you hold the command; releasing it stops the gate. This is a temporary emergency mode, not a substitute for repair. Never bypass a safety device for continuous operation.
Maintenance and servicing
Carry out maintenance at least every 6 months or after 20,000 operations, whichever comes first. Disconnect the power supply; check the fastenings, corrosion, wear on the wheel and rack, alignment, and free movement; clean the photocells and repeat the safety tests. The service indicator does not replace regular maintenance.
Maintenance warning
The threshold is set by II/L7. If maintenance should also be indicated by S.C.A., set II/L4 = L7.
| Counter status | FLASH / maintenance indicator |
|---|---|
| Below 80% of the threshold | FLASH flashes normally; the indicator lights for 2 seconds when opening begins. |
| 81–100% of the threshold | FLASH stays on for 2 seconds at the start, then flashes normally; the indicator flashes during operation. |
| Above 100% of the threshold | FLASH stays on for 2 seconds at the start and end; the indicator flashes continuously. |
Checking the number of operations
- Enter SET programming mode for about 3 seconds; release when L1 flashes.
- Use OPEN/CLOSE to select input L7.
- Hold SET and wait about 3 seconds for the LED showing the current value to light up.
- While holding SET, briefly press OPEN + CLOSE together, then release them.
- The number of flashes from the value LED indicates the threshold used, in increments of ten percentage points; no flashes means the value is below 10%. Release SET.
Resetting the service counter
- After maintenance has been carried out, select II/L7 using the same procedure.
- Hold SET and wait about 3 seconds for the value LED to light up.
- While still holding SET, press OPEN + CLOSE for at least 5 seconds, then release both buttons.
- Rapid flashing confirms the reset; release SET and wait for programming to finish.
This procedure resets the service counter. It does not delete transmitters or replace travel learning or a full control unit reset. If there is an electronics fault, do not try an unverified button combination; follow the diagnostics and service procedure for the specific RUA1.
Troubleshooting
Before working on an open operator, disconnect the power supply. Measurements on mains voltage or live terminals must be carried out by a qualified person. Contact our technical support team with the motor model, control board identification, and number of flashes.
By fault symptom
| Symptom | What to check |
|---|---|
| The remote control does not light up | Check the battery and contacts in the remote control as described in its manual. |
| The remote control lights up, but the gate does not respond | Receiver compatibility and memory; pairing. Also test the button or P.P. input to distinguish a radio issue from an operator fault. |
| BLUEBUS is not lit | Check the mains supply and fuses with the power safely disconnected; do not bypass safety devices. |
| The command is not registered | When a BLUEBUS input changes, it flashes rapidly twice; an NO command on P.P./OPEN/CLOSE should light the corresponding LED. Check the contact and cable. |
| The gate starts moving, stops, or reverses | First check manually for friction, track issues, carriage problems, ice, rack play, and stop positions. Then check the force/sensitivity setting; any change requires a new impact force measurement. |
| The warning light does not work | Check FLASH, wiring, short circuits, and warning light compatibility. While flashing, the measured voltage may vary between approximately 10–30 V DC; this is not a constant 24 V supply. |
| S.C.A. does not work | First check mode II/L4, then the load (up to 4 W), cable, and output (approximately 24 V DC). |
| The limit switch does not stop movement | Check the brackets are securely fastened and correctly positioned; for the RUN2500P, also check the 3–8 mm clearance. If the direction is wrong, stop the operator and correct the direction selector. |
Warning light diagnostics
The light flashes regularly during normal operation. An error code consists of a series of flashes, a 1-second pause, and the same series repeated; count the flashes in one series.
| Flashes | Meaning / remedy |
|---|---|
| 1 | BlueBUS Check the devices, wiring, and addresses. Repeat the learning procedure after repairs or a deliberate change to the setup, not to mask a faulty safety device. |
| 2 | Photocell A normal response if the beam is interrupted in the protected direction. If the path is clear, check that the photocells are clean and aligned, and check their addresses. |
| 3 | Obstacle / resistance detection Remove the obstacle and eliminate mechanical resistance. Do not increase Force or Peak without checking the gate and carrying out a subsequent safety test. |
| 4 | STOP The learned status has changed. Check the safety edge, contacts, and wiring; do not bypass the safety device. |
| 5 | Internal parameters Wait 30 seconds and try the command again. If the fault recurs, have the RUA1 serviced. |
| 6 | Operation limit / temperature Wait a few minutes and let the motor cool down. Check the required operating frequency and mechanical resistance. |
| 7 | Electronic circuits Disconnect the power supply for a few seconds and try again. If the fault persists, contact the service team. |
| 8 | Continuous command Check the timer or for a control input that is continuously active. This may be expected if the gate is intentionally being held open. |
Control unit LEDs
BLUEBUS, STOP, P.P., OPEN, CLOSE
| LED / status | Meaning |
|---|---|
| BLUEBUS is not lit | No power or a fault. Check the mains supply and fuses. |
| BLUEBUS is continuously lit | Serious fault. Safely disconnect the power supply and check the wiring; if the fault recurs, contact service. |
| BLUEBUS flashes once per second | Normal operation. |
| BLUEBUS flashes twice rapidly | Input status changed or a command was received. |
| BLUEBUS series of flashes | Code as in the beacon diagnostics. |
| STOP lit | Correct STOP status learned. |
| STOP not lit | STOP status changed or learning incomplete; check the safety device. |
| P.P./OPEN/CLOSE lit | The corresponding volt-free contact is active. |
| P.P./OPEN/CLOSE not lit | The corresponding contact is not active. |
LEDs L1–L8
During normal operation, lit means the Level I function is enabled; unlit means it is disabled. L1 automatic closing, L2 closing after photocell activation, L3 always close, L4 slowdown, L5 Peak, L6 pre-flashing, L7 CLOSE = partial opening, L8 Slave. A single flashing LED may indicate programming; L1/L2 together indicate a request to learn devices, and L3/L4 together indicate travel learning.
Reading the error history
- Press SET for about 3 seconds, then release when L1 flashes; use OPEN/CLOSE to select input L8.
- Hold SET; after about 3 seconds, the LEDs for manoeuvres during which an error was recorded will light up.
- While holding SET, use OPEN/CLOSE to select a specific record. L1 is the most recent; L8 is the eighth most recent.
- Read the number of flashes for the selected record using the beacon diagnostics. Release SET and wait for programming to finish.
Manual release for NICE RUN2500P
Stop the gate, disconnect the power supply, and secure the leaf against uncontrolled movement. Release the gate only while it is stationary.
- Slide the lock cover aside.
- Insert the key and turn it clockwise.
- Pull out the release lever.
- Move the leaf manually and under control.
To re-engage the drive, carry out the procedure in reverse. Make sure the gearbox has re-engaged before restoring power. Keep the key accessible even when the entrance is closed.
NICE RUN2500P technical specifications
Specifications for the 230 V RUN2500P version. Always check the electrical values and version against the rating plate on the supplied motor. Rated values apply at approximately 20 °C.
| Parameter | Value |
|---|---|
| Model | RUN2500P – inductive, non-contact limit switch |
| Type and control | Electromechanical sliding gate operator, RUA1; plug-in radio receiver not included with the standalone motor. |
| Motor and mains supply | 230 V AC, 50/60 Hz; tolerance as specified on the rating plate of the supplied version. |
| Maximum weight / length | 2,500 kg / 18 m; additional conditions and available cycles according to the suitability tables. |
| Gear | 18 teeth, module 4, pitch approximately 12.6 mm; pitch diameter 60 mm. |
| Peak torque / force | 50 Nm / 1,390 N |
| Rated torque / force | 30 Nm / 830 N |
| No-load speed | 0.17 m/s at 50 Hz, approximately 10.2 m/min. |
| Rated speed | 0.14 m/s at 50 Hz, approximately 8.4 m/min. |
| Rated frequency with a 15 m gate leaf | 15 cycles/h at rated torque and with a 15 m leaf. Limits based on length, weight and temperature also apply; this is not the number of cycles that can be run continuously. |
| Continuous operation | Maximum 60 min at rated torque, subject to additional cycle limits. At 50 °C, maximum 10 min; with a 15 m leaf, maximum 7 cycles/h. |
| Power consumption / current | Starting: 870 W / 3.8 A; rated: 600 W / 2.7 A. |
| Electrical protection | Class I – PE protective earthing. |
| FLASH | One or two beacons, each with a 12 V / 21 W lamp; not intended as a continuous auxiliary power supply. |
| S.C.A. | 24 V DC, max. 4 W, voltage −30% / +50%. |
| Auxiliary power supply | 24 V DC, −30% / +50%, max. 100 mA total; correct STOP/P.P. polarity. |
| BlueBUS | Max. 15 load units; photocells are polarity-independent. |
| STOP | Volt-free NO/NC or 8.2 kΩ resistor; learned status. |
| P.P., OPEN, CLOSE | Volt-free NO contacts. |
| Radio / antenna | SM connector; receiver selected separately. 52 Ω antenna input, RG58 or similar coaxial cable. |
| Programming | 8 ON/OFF functions and 8 parameters; Levels I and II. |
| Learning | BlueBUS devices, STOP input type, and travel length with slowdown/partial-opening points. |
| Operating temperature | −20 to +50 °C |
| Ingress protection rating | IP44 |
| Unsuitable environments | Acidic, saline or potentially explosive atmospheres. |
| Overall dimensions | 400 × 255 × 390 mm according to the technical table; installation dimensions are shown in the original drawing below. |
| Motor weight | 24.5 kg |
| Service life | Approximately 150,000–450,000 cycles depending on the sum of the indices and the chart; not a guarantee. |
Operator dimensions
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]