NICE Run RUN2500 – standalone operator for sliding gates (A)


Product availability: within 3 days

We usually dispatch goods within 3 days.


NICE Run RUN2500 – standalone operator for sliding gates (A) NICE Run RUN2500 – standalone operator for sliding gates (A)
NICE-RUN2500-A
within 3 days
€681.00 excluding VAT
€837.63 including VAT

 pcs
Weight
25 kg

Description of NICE Run RUN2500 – standalone operator for sliding gates (A)

NICE RUN2500 – sliding gate operator

NICE RUN2500 is a standalone unit non-reversible electromechanical operator with built-in control unit RUA1. Both the motor and mains supply are 230 V AC. It has an electromechanical limit switch.

For a single gate leaf weighing up to 2,500 kg and measuring 18 m; suitability also depends on travel resistance and frequency of use. The standalone operator does not include a receiver, remote control, photocells or rack. The cover is impact-resistant; the body is made of epoxy-coated aluminium alloy.

Quick navigation
KitsAccessoriesSelection and limits
InstallationLimit switchesWiring
24 V polarityInitial startupProgramming
FaultsManual releaseSpecifications
MaintenanceTwo operatorsPDF manual

Standalone operator or kit

The letter at the end of a kit designation indicates the included equipment. The motor model remains RUN2500; P means an inductive limit switch, not a more powerful motor.

Kit with accessoriesStandalone operatorKit with rack

NICE RUN2500D

NICE RUN2500D operator kit

1 × RUN2500 with RUA1, 1 × OXIBD, 1 × MYGO4. 1 pair EPMB. 1 × ELDC.

Details and price

NICE RUN2500

NICE RUN2500 – standalone operator with RUA1 control unit

Mechanical limit switch.
230 V motor and RUA1.
No receiver, remote control, photocells or rack included.

NICE RUN2500F

NICE RUN2500F operator kit

1 × RUN2500 with RUA1, 1 × OXIBD, 1 × MYGO4. 1 pair EPMB. 1 × ELDC. Plus 4 m of rack LZ-1.

Details and price

Next kitEquipment differences
NICE RUN2500BMotor and RUA1, OXIBD receiver and 1 remote control; no photocells, warning light or rack.
NICE RUN2500CB equipment + 1 pair of EPMB photocells; no warning light or rack.
NICE RUN2500EC equipment + 4 m of LZ-1 rack; no warning light.

The rack included in the kit is not automatically suitable for the full 2,500 kg maximum load. For a heavy gate, choose the load capacity and material according to the rack selection guide; agree on any changes to the included equipment before ordering. Four metres of rack cover only the corresponding length of travel.

Accessories for RUN2500

Select the required equipment below to suit your gate and the receiver actually installed. The built-in RUA1 does not replace a radio receiver or safety devices.

What Why Type
Beacon

Alerts you to movement and reports faults. Connects to FLASH; the antenna has a separate coaxial cable.

  • LED beacon with antenna ELDC
  • Multifunction light WLT
Photocells

Detect an obstruction in the beam; the response is determined by pair address. They do not replace protection at all hazardous points on the gate.

BlueBUS wiring; FT210B for a moving safety edge. The TX and RX of one pair have the same address.

Transmitter

Choose according to the coding and type of receiver installed. The same frequency alone does not confirm compatibility; LoRa and two-way functions require a compatible receiver.

Receiver selection and pairing

Receiver

The radio receiver plugs into the SM connector; pairing depends on the receiver. Wi-Fi/GSM requires a supported interface or a volt-free P.P. contact.

Other Wi-Fi modules

Antenna

For improved remote control range.

  •  integrated into the beacon ELDC
  • standalone antenna ABFKIT
Keypad

EDSWG requires a compatible radio receiver. For EDSB, the specific RUA1 version must support BlueBUS control devices; the bus alone does not prove compatibility.

Key Switch

Control the gate with a key using a switch wired to the drive at any convenient location.

Voltage-free contact to P.P.; power the lighting separately, according to polarity and current draw.

  • surface-mounted, with standard cylinder EKS
  • surface-mounted, with European cylinder, EKSEU
  • flush-mounted, with standard cylinder EKSI
  • flush-mounted, with European cylinder EKSIEU
Card Readers

Use ETPB only after confirming that the installed RUA1 supports BlueBUS control devices. Connect the reader with a voltage-free relay to P.P. and power it separately according to its current draw.

  • ERA Transponder Reader ETPB
Toothing

Required module 4 rack. Choose the material, fixing method and load capacity for the complete gate leaf; a nylon rack is not automatically suitable for the 2,500 kg maximum.

  • nylon, with steel reinforcement, 33 cm LZ-1
  • nylon, with steel reinforcement, 1 m LZ-10

    LZ-10 is an older, discontinued type. The current replacement is LZ-21 with a different segment joint; when repairing, check that it matches the existing rack.

  • nylon, with steel reinforcement, reverse, 1 m LZ-15
  • steel, 30x8mm, 1 m LZ-3
  • steel, 30x12mm, 1 m LZ-5
  • stainless steel, 30x10mm, 1 m LZ-7

Power outage

The motor is powered from a 230 V mains supply. PS124 and Solemyo do not provide a direct backup for this drive. Use the manual release during a power outage.

What the drive can do

BlueBUS connects compatible photocells using a two-core cable; supported safety addresses and the limit of 15 load units are listed in the photocell wiring. Adjustable force, obstacle sensitivity, automatic closing pause and deceleration are listed in the programming tables.

Thermal protection prevents the motor from overheating and reduces the permitted number of cycles at high temperatures. Faults are indicated by the warning light and LED. The Master/Slave connection allows two opposing sliding gate leaves to be synchronised.

The gear wheel uses module 4; the rack must be suitable for the gate's weight and construction. Safety must be verified on the complete, finished gate, including protection at hazardous points and impact forces. The gate must have solid end stops and protection against coming off the guide.

Choosing the NICE RUN2500 drive

The deciding factors are the weight and length of the entire moving gate leaf, including the infill and counterweight, not just the clear opening width. Check that the gate moves freely by hand along its entire travel. The force required to start moving must be less than 695 N and the force required to keep it moving must be less than 415 N; these are half the peak and rated forces, respectively. Allow for winter conditions, ice and any further increase in resistance.

ParameterManufacturer's maximumOur approximate recommendation
Gate leaf weight2 500 kgUp to 2 000 kg
Gate leaf length18 mApproximately up to 14.4 m

A recommended allowance of approximately 20% helps with typical selection. This does not confirm suitability for every gate of this kind; the mechanics, actual forces and required operating frequency still need to be checked.

Maximum number of cycles

One cycle consists of a complete opening and closing. First select the row by gate length; multiply both figures by the weight factor and round the result down. Heavy movement and high temperatures may further reduce the available number.

Gate leaf lengthMax. cycles/hourMax. consecutive cycles
Up to 6 m4242
Over 6 up to 9 m2828
Over 9 up to 12 m2121
Over 12 up to 15 m1717
Over 15 up to 18 m1414

Gate leaf weightAvailable cycle percentage
Up to 500 kg100 %
Over 500 up to 900 kg80 %
Over 900 up to 1,200 kg75 %
Over 1,200 up to 1,500 kg60 %
Over 1,500 up to 1,800 kg50 %
Over 1,800 up to less than 2,000 kgNo coefficient is specified; individual confirmation of operation is required.
2,000 to 2,300 kg40 %
Over 2,300 up to 2,500 kg30 %

For a gate leaf of 16 m / 2,400 kg the calculation is 14 × 0.30 = 4.2: for planning, no more than 4 cycles/hour and 4 consecutive cycles, before any further temperature-related reduction. Thirty percent means the available proportion, not a 30 % deduction. For a gate leaf weighing between 1,800 and 2,000 kg, the coefficient cannot be inferred from the adjacent rows.

Estimated service life

Add the weight, length and other-factor indices for conditions likely to occur during more than 10 % of operation. Use the total in the chart. The cycle count is an approximate estimate, not a guarantee or a fixed number of years.

Characteristics of the complete automation systemIndexService life chart
Weight up to 500 kg5 %RUN2500 and RUN2500P – estimated service life chart

Horizontal axis: index in %.
Vertical axis: estimated cycles.

Over 500 up to 900 kg10 %
Over 900 up to 1,200 kg20 %
Over 1,200 up to 1,500 kg30 %
Over 1,500 up to 1,800 kg40 %
Over 1,800 up to 2,200 kg50 %
Over 2,200 up to 2,500 kg60 %
Length up to 6 m5 %
Over 6 up to 9 m10 %
Over 9 up to 12 m15 %
Over 12 up to 15 m25 %
Over 15 up to 18 m35 %
Over 40 °C / below 0 °C or humidity above 80 %10 %
Dust and sand15 %
Salinity of the environment20 %
Photocell interruption10 %
STOP interruption20 %
Peak function enabled10 %


Example: 2,400 kg / 16 m: 60 % + 35 % = 95 % before any other factors. Frequent photocell interruptions add 10 %, for a total of 105 %: this is outside acceptable limits. The mere presence of photocells does not mean that an index is automatically added. Do not use the operator in acidic, saline or explosive atmospheres; the salinity index does not constitute permission for such use.

Operator and controls in pictures

manual release control unit wiring diagram
 Manual release  RUA1 control unit  RUA1 wiring with ELDC, EPMB and EKS
Manual release » RUA1 control unit » RUA1 wiring with ELDC, EPMB and EKS »

Installing the NICE RUN2500 operator

Mount the operator on a solid, level foundation, away from areas that could flood. Determine the height based on the actual position of the rack and pinion. A cantilever gate may require a higher foundation or a suitable rigid bracket; its design must safely withstand the load. The gate must not place its weight on the motor.

Wiring

Route the mains supply separately from low-voltage and signal cables. Select accessories, wiring and protection according to the specific installation. Original typical setup:

NICE Run wiring setup

  1. Key switch
  2. Photocells on a post
  3. Photocells
  4. Static safety edge 1
  5. Moving safety edge 1
  6. Drive opening end stop
  7. Rack rail
  1. Static safety edge 2
  2. Warning light with built-in antenna
  3. NICE Run RUN2500 drive
  4. Drive closing end stop
  5. Moving safety edge 2
  6. Remote control

PurposeCableMax. length
A – mains supply3 × 1.5 mm²30 m; over 30 m, at least 3 × 2.5 mm², subject to assessment of voltage drop and protection
B – warning light2 × 0.5 mm²20 m
B – antennaRG58 coaxial cable20 m; under 5 m recommended
C – BlueBUS2 × 0.5 mm²30 m; for 30–50 m, 2 × 1 mm²
D – key switch2 cables, 2 × 0.5 mm² or 4 × 0.5 mm²50 m
E – fixed safety edges2 × 0.5 mm²20 m
F – moving safety edge2 × 0.5 mm²30 m; moving cable or FT210B

Foundation installation and inspection

  1. Before installation, disengage the drive and check for smooth manual movement, proper guidance, secure end stops and protection against the gate leaf lifting off its track.
  2. Prepare the cable conduits and the base plate with four anchors. Leave no more than 40 mm of thread protruding above the plate.
  3. Level the plate, set it in a solid foundation and allow the concrete to cure properly. Do not install the motor on a soft or unstable surface.
  4. Secure the motor with four nuts and washers, position it relative to the rack, then tighten the fasteners.
  5. Check the clearance, rack joints, gate guidance and switch positions along the entire travel path. Secure the cables so they cannot come loose and enter moving parts.

Rack rail and end positions

The gate moves by transferring the drive sprocket’s rotary torque into linear motion through the rack-and-pinion system on the drive rack. Two types of rack rail are most commonly used:

Nylon drive rack

Nylon rack (with steel reinforcement, if required) – attaches to the gate using self-tapping screws through the mounting holes. Ideal for relatively lightweight, shorter gates. Friction between the steel drive sprocket and nylon rack makes operation quiet.

Steel drive rack

Steel rack – attaches to the gate by welding on threaded brackets, which the rack is then screwed into. Used for longer and heavier gates. Friction between the steel drive sprocket and steel rack makes operation slightly noisier.

The key requirement is that the drive tooth module is compatible with the rack module. Drive NICE Run RUN2500 has a tooth module of 4.

The drive detects the end position when opening and closing using limit-switch brackets mounted on the rack:

1. Level the drive using the four adjustment points 2. The gate and drive must be level 3. Leave approximately 1–2 mm of clearance between the rack and drive sprocket so the weight of the gate is not transferred to the drive.
Leveling the drive Sliding gate with rack rail Leave 1–2 mm of clearance between the rack and drive sprocket
4. Tighten the drive mounting so it cannot shift when engaged

5. Adjust the limit-switch brackets according to the instructions below. Fixed mechanical stops must remain at both ends of the travel path.

 
Tighten the drive and cap the ends Fitting the end stops to the rack rail  

Maintain 1–2 mm clearance between the rack and pinion

Clearance 1–2 mm must be maintained along the entire travel path. Align the rack with the pinion; manually run the gate along its track and check for lateral deviations of no more than 5 mm and smooth transitions between sections. After adjustment, securely tighten the motor.

Setting the limit switches

The RUN2500 has an electromechanical limit switch. The brackets on the rack operate its lever.

  1. Move the gate leaf manually to the open position, at least 2–3 cm before the fixed stop.
  2. Slide the bracket along the rack in the opening direction until it actuates the limit switch.
  3. Move the bracket at least 2 cm farther in the same direction and secure it.
  4. Also adjust the closed-position bracket.
  5. After locking the gearbox and programming the travel, check that the gate stops before both mechanical stops.

RUN2500 – electromechanical limit switch bracket

Wiring the NICE RUN2500 operator

Disconnect the mains supply and verify that the circuit is de-energized before opening, wiring, or disconnecting terminals. The mains supply is 230 V AC; accessory terminals have different voltages and functions.

230 V AC mains supply

The mains circuit must have suitable overcurrent protection and residual-current protection, as well as a reliable PE connection. Use a disconnecting device in accordance with installation regulations; if it is not located by the operator, it must be capable of being secured against accidental switching on.

TerminalWire and function
LLive wire; usually brown.
NNeutral wire; usually blue.
PE / protective earthGreen/yellow protective conductor. Class I requires a reliable protective earth connection.

RUA1 – L, N and protective earth for the mains supply

Route the mains cable through the smaller grommet and the other cables through the larger one. Fit the membranes snugly around the cables, restore the seal, and secure the wiring against pullout. Leave the required slack inside, approximately 20–30 cm; cables must not obstruct the cover or moving parts.

RUA1 control unit terminals

TerminalUse, voltage and polarity
FLASH – warning light

ELDC connect with a two-core cable to FLASH, according to the warning light terminal detail. The output is for a low-voltage warning light; its load limit supports one or two warning lights, each with a 12 V / 21 W bulb. This is not a permanent accessory power supply. WLT has its own setting. If applicable, follow the +/− markings on the actual warning light and board; do not assume the polarity of the auxiliary output.

S.C.A. – indicator24 V DC, maximum 4 W, voltage −30% / +50%. Function according to II/L4. For polarized accessories, check the +/− terminals on the specific board; their order cannot be determined from the diagram below.
BLUEBUSPower and communication for compatible devices. Photocells connect without polarity. Total limit: 15 BlueBUS load units. For two Master/Slave motors the wire order must be followed exactly.
STOPVoltage-free NO, NC or 8.2 kΩ resistive devices; the RUA1 learns the type. A change in the learned state stops movement and briefly reverses it. The contacts have no +/− polarity and must not be connected to an external voltage source.
P.P. / STEP-BY-STEPVoltage-free NO step-by-step contact. Connect the module relay's COM and NO contacts to the two P.P. terminals; the contact is non-polarized. The module power supply requires separate wiring.
OPENVoltage-free NO contact for opening; non-polarized.
CLOSEVoltage-free NO contact for closing; when I/L7 is ON, it opens partially. Non-polarized.
AERIAL / antennaConnect the coaxial cable's center conductor and shield according to the receiver/board terminal markings. These are not power-supply +/− terminals. RG58, 52 Ω input; choose an antenna to match the receiver frequency.

Multiple devices on STOP

Wire NO contacts in parallel and NC contacts in series. Two 8.2 kΩ resistive devices can be wired in parallel; for more than two, use a configuration with a single 8.2 kΩ end-of-line resistor as shown in the device diagram. A combination of NO and NC requires an 8.2 kΩ resistor in series with the NC branch. Do not replace a safety edge with a simple jumper. After making a change, repeat the learning procedure and safety test.

Fuses

Check only after disconnecting the mains supply. Replace fuses F1/F2 with the same type, time-current characteristic and rating specified on the installed board. If a fuse blows repeatedly, identify the cause; do not install a higher-rated fuse.

NICE RUN2500 operator fuses

RUA1 wiring with ELDC, EPMB and EKS

The terminals along the top edge of the RUA1 are, from left to right, FLASH, S.C.A., BLUEBUS, STOP, P.P., OPEN and CLOSE, with the board oriented as shown in the image. The antenna has a separate connector.

RUA1 – original accessory terminal layout

RUA1 – wiring the ELDC warning light, EPMB photocells and EKS key switch

Accessory illustrations are schematic; check the terminals against the markings on the supplied product. EKS here controls OPEN and CLOSE using two contacts C (common) + NO (normally open). For step-by-step control, connect the selected C + NO contact to the two P.P. terminals. Voltage-free contacts are non-polarized; do not connect an external power supply to them.

The diagram shows the default CLOSE function. If you enable the L7 function in level I, this input will control partial opening instead of closing.

ELDC warning light and its antenna

Connect both wires from the FLASH output on the RUA1 to the pair of ELDC terminals marked with the light bulb symbol. ELDC is a low-voltage LED warning light for 12–36 V DC; 230 V mains must not be connected to these terminals. The light and antenna terminals are separate. The FLASH output flashes and also transmits diagnostic sequences.

ELDC – original detail of the light and antenna terminals

With the ELDC detail in the same orientation, the pair of FLASH terminals is on the left and the pair for the antenna is on the right. In the antenna pair, the left terminal is for the coaxial cable’s centre conductor and the right one for the shield. Connect the other end of the coaxial cable according to the symbols at the RUA1 antenna input or according to the antenna wiring to the OXIBD, if you are using its input. The shield must not be shorted to the centre conductor.

The light’s power supply pair is not marked +/− in this detail. If the supplied beacon version or circuit board has marked polarity, observe it; the polarity of the auxiliary 24 V supply is not carried over to FLASH. For the light, use 2 × 0.5 mm²; for the antenna, use a separate RG58 cable as specified in the wiring table.

EPMB and BlueBUS photocells

NICE EPMB connect to the BLUEBUS pair on the RUA1, with no +/− polarity. Both wires carry power and communication; they must not be connected to the auxiliary 24 V output. TX is the transmitter and RX is the receiver. TX and RX in one pair must have the same address; the next pair must have a different one. The controller supports up to 15 BlueBUS load units; the number of units is not necessarily the number of pairs. BlueBUS system overview.

Parallel connection of one or more pairs

NICE EPMB – parallel connection of TX and RX to the two BlueBUS terminals

Mount the photocells opposite each other and align their optical axes. For multiple pairs, also observe the TX/RX orientation, to prevent them from interfering with each other. After adding or removing a device, perform device learning and test all safety beams.

Photocell placement for a sliding gate

NICE EPMB – layout and TX/RX orientation for a single-leaf sliding gate

The illustration shows possible positions, not equipment required for every gate. Select the function of each safety pair according to the RUA1 address table. FT A / FT B denote separate optical devices for the moving edge, not another standard EPMB pair.

For EPMB safety wiring, do not interrupt connection A on either TX or RX. The FA1/FA2 addresses shown in the illustration are control functions for triggering opening; they are not among the seven RUA1 safety addresses in the table below. Use them only if support by the specific control unit has been confirmed.

EPMB photocell addresses and jumpers

Set the jumpers with the power disconnected, and set them identically on TX and RX. Store any unused jumper in the designated place on the photocell. No two pairs on the same network may have the same address. The illustrations show the jumper configuration, not the power supply polarity.

Address and function on the RUA1TX and RX jumpers
FOTO
Outer pair at approximately 50 cm height; protection during closing.
EPMB – FOTO address jumpers
FOTO II
Outer pair at approximately 100 cm height; protection during closing.
EPMB – FOTO II address jumpers
FOTO 1
Inner pair at approximately 50 cm height; protection during closing.
EPMB – FOTO 1 address jumpers
FOTO 1 II
Inner pair at approximately 100 cm height; protection during closing.
EPMB – FOTO 1 II address jumpers
FOTO 2
Outer pair; protection during opening.
EPMB – FOTO 2 address jumpers
FOTO 2 II
Inner pair; protection during opening.
EPMB – FOTO 2 II address jumpers
FOTO 3
The only safety pair for the entire automation system. If FOTO II is also installed, observe TX/RX orientation and check for mutual interference.
EPMB – FOTO 3 address jumpers

When replacing a photocell, retain the correct address and verify that it is detected and responds safely. If the number or address of devices changes, repeat the learning procedure. During testing, interrupt the beam while opening and closing, and check that the response matches the selected function.

Moving safety edge and FT210B

NICE FT210B transmits the status of an 8.2 kΩ resistive safety edge via an optical beam. The TX on the gate leaf is powered by its own battery; the RX is connected to BlueBUS with no polarity. Set the safety edge address and wiring according to the FT210B instructions; this is not a standard pair with a wired power supply to the TX. The RX power consumption counts towards the BlueBUS load.

Radio receiver for the drive

For a new setup, you can choose NICE OXIBD for the SM connector. For an existing setup, select transmitters according to the SMXI/OXI receiver actually installed. Insert the receiver with the mains power disconnected; pair transmitters according to the remote control pairing instructions and the specific receiver. Radio memory, travel learning and RUA1 settings are separate functions.

Drive radio receiver

NICE Run RUN2500 drive is supplied with a NICE RUA1 control unit, which provides an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is required to receive commands sent from remote controls, and is therefore essential for operating the sliding gate remotely by remote control.

Selecting the direction of gate travel

The direction of travel of the sliding gate must be selected with its position in mind of the operator relative to the sliding gate leaf. View the gate from the side where the operator is installed.

Select the sliding gate opening direction: left Select the sliding gate opening direction: right
If the gate opens to the left, set the switch to the left. If the gate opens to the right, set the switch to the right.

The switch is on the right-hand side of the RUA1 control unit in the middle.

Initial power-up and device learning

Leave the gate leaf approximately halfway along its travel, engage the gearbox, and check the direction setting, limit switches, and clear travel path. Switch on the power. BLUEBUS should flash about once per second; the photocell TX/RX indicators should show activity, and FLASH/S.C.A. should be off while the gate is stationary and closed, depending on the configured mode. If the status is incorrect, disconnect the power and rectify the fault first.

  1. Press and hold OPEN + STOP/SET for approximately 3 seconds.
  2. Release when L1 and L2 start flashing rapidly.
  3. Wait for BlueBUS and the STOP input to finish being detected. L1/L2 will stop indicating that learning is required, and the STOP LED must be lit; L3/L4 may continue flashing because the travel path has not yet been learned.
  4. After adding or removing a device, repeat the learning procedure and test its safety function again.

Learning the travel distance

  1. After device learning is complete, press and hold CLOSE + STOP/SET for approximately 3 seconds.
  2. Release when movement starts. The first movement must be opening.
  3. If the gate closes, stop it with STOP, disconnect the power, correct the direction setting, and repeat the learning procedure.
  4. Allow the gate to open fully to the limit switch, then close completely to the other limit switch. Do not obstruct the travel path during learning.
  5. Check the end positions, partial opening, and several complete cycles.

Assessing connected devices for the NICE Run RUN2500 operator

Assessing sliding gate leaf length with the NICE Run RUN2500 operator

Testing and handing over the gate

Check movement in both directions, the operator and rack mounting, the limit switches and mechanical stops, and each safety device individually. Test the photocells during opening, closing, and while stationary, as applicable to their function. Impact forces must be measured; repeat the test after changing the force, sensitivity, or acceleration settings. Do not put the gate into service if its safety protection is not working. Give the user the keys and instructions, and explain manual release and maintenance.

Programming the operator

The RUA1 board has OPEN, STOP/SET, and CLOSE buttons, plus eight LEDs, L1–L8. The gate must be stationary before making changes. After changing safety settings, test the complete gate system.

ButtonNormal operation / programming
OPEN ▲Open / move to the next LED.
STOP/SETStop / enter settings and confirm.
CLOSE ▼Close / move to the previous LED.

Level I – switching functions on and off

  1. Press and hold STOP/SET until L1 starts flashing, approximately 3 seconds; release the button.
  2. Use OPEN/CLOSE to select the function LED.
  3. Briefly press SET to toggle ON/OFF. In programming mode, a short flash indicates OFF and a long flash indicates ON.
  4. Set the next function in the same way, or wait 10 seconds without pressing any button. The settings are saved and programming ends.

LED – function and descriptionStatus
L1 – Automatic closing
After opening, the gate closes after the pause set by II/L1. The factory-set pause is 30 seconds. When OFF, it waits for a command.
OFF – factory setting
ON – function enabled
L2 – Close after photocell activation
After the passage is clear, the gate closes after 5 seconds. With I/L1 OFF, the gate first opens fully; with I/L1 ON, opening stops once the photocells are clear. A STOP command cancels this function for the current operation.
OFF – factory setting
ON – function enabled
L3 – Always close
After power is restored, an open gate closes; the warning beacon flashes for 5 seconds before movement. When OFF, the gate remains stationary after power is restored.
OFF – factory setting
ON – function enabled
L4 – Slowdown
At the end of opening and closing, speed is reduced to approximately 60% of the nominal speed. Available torque is halved; slowdown may not be suitable for a heavy gate or one with high resistance.
OFF – factory setting
ON – function enabled
L5 – Boost
When ON, soft start is disabled and maximum starting force is used. This does not replace fixing friction, track problems, or a frozen gate. Check that forces are safe after making changes.
OFF – factory setting
ON – function enabled
L6 – Pre-flashing
The beacon gives a warning 3 seconds before movement. When OFF, it starts flashing only when movement begins.
OFF – factory setting
ON – function enabled
L7 – CLOSE = partial opening
A CLOSE command from the terminals or radio control triggers partial opening as set by II/L6. When OFF, it means closing.
OFF – factory setting
ON – function enabled
L8 – Slave unit
Enable this only on the second motor in a Master/Slave configuration. When OFF, the operator is the Master.
OFF – factory setting
ON – function enabled

Outside programming mode, the LED for a function is lit when ON and unlit when OFF. L1/L2 or L3/L4 flashing simultaneously may indicate that device or travel learning is required; see LED diagnostics.

Level II – adjustable values

  1. Press and hold SET until L1 starts flashing, approximately 3 seconds; release.
  2. Use OPEN/CLOSE to select the parameter’s input LED.
  3. Press SET again and hold it while adjusting. After approximately 3 seconds, the LED for the current value lights up.
  4. While holding SET, select the value using the OPEN/CLOSE buttons. Then release SET.
  5. Repeat the procedure for the next parameter; to exit, wait 10 s without pressing any buttons.

Input LED – name and descriptionSetting LED – value
L1 – Pause duration
Automatic closing time when I/L1 is enabled.
L1 – 5 s
L2 – 15 s
L3 – 30 s (factory setting)
L4 – 45 s
L5 – 60 s
L6 – 80 s
L7 – 120 s
L8 – 180 s
L2 – Step-by-step mode
Command sequence for P.P. and the corresponding radio channel.
L1 – Open → stop → close → stop
L2 – Open → stop → close → open (factory setting)
L3 – Open → close → open → close
L4 – Shared entrance: while opening, ignores the next command; while closing, it reopens
L5 – Shared entrance 2: as for L4; a command held for more than 2 s stops the gate
L6 – Step-by-step 2: a short command of up to 2 s triggers partial opening
L7 – Hold-to-run: movement continues while the command is held
L8 – Semi-automatic opening; closing while the command is held
L3 – Obstacle sensitivity
Higher sensitivity responds to less resistance. First set the motor force at II/L5, then adjust sensitivity; measure impact forces after changing the setting.
L1 – Very high – lightweight gates
L2 – Very high
L3 – High
L4 – Medium
L5 – Medium-low (factory setting)
L6 – Low
L7 – Very low
L8 – Very low – heavy gates
L4 – S.C.A. output
24 V output function / max. 4 W. The available radio channels also depend on the receiver.
L1 – Gate-open indicator: off when closed, on when open; flashes slowly while opening and quickly while closing (factory setting)
L2 – Active when the gate is closed
L3 – Active when the gate is open
L4 – Radio output 2
L5 – Radio output 3
L6 – Radio output 4
L7 – Maintenance indicator
L8 – Electric lock
L5 – Motor force
Torque control. Force is not determined by weight alone; do not use excessive force to overcome a mechanical fault.
L1 – 40%
L2 – 50%
L3 – 60%
L4 – 80%
L5 – 100%
L6 – Semi-automatic 40–100%
L7 – Semi-automatic 60–100%
L8 – Automatic 0–100% (factory setting)
L6 – Partial opening
Pedestrian opening distance. Must fit within the gate’s actual travel distance.
L1 – 0.5 m
L2 – 1.0 m (factory setting)
L3 – 1.5 m
L4 – 2.0 m
L5 – 2.5 m
L6 – 3.0 m
L7 – 3.4 m
L8 – 4.0 m
L7 – Maintenance warning
Number of movements since servicing. Opening and closing count as two movements; one complete cycle consists of an opening and a closing movement.
L1 – Automatic, based on operating load (factory setting)
L2 – 2,000 movements
L3 – 4,000 movements
L4 – 7,000 movements
L5 – 10,000 movements
L6 – 15,000 movements
L7 – 20,000 movements
L8 – 30,000 movements
L8 – Error log
Records of the last eight movements; this is not a configurable default value.
L1 – Most recent movement
L2 – Second most recent movement
L3 – Third most recent movement
L4 – Fourth most recent movement
L5 – Fifth most recent movement
L6 – Sixth most recent movement
L7 – Seventh most recent movement
L8 – Eighth most recent movement

Two sliding gate leaves – Master/Slave

Each leaf has its own RUN and its own 230 V AC mains supply. One motor is the Master, the other the Slave. Using two motors does not increase the weight or length limit for an individual leaf.

BlueBUS connection

Maintain the wire order between the motors: terminal 1 Master → 1 Slave and 2 Master → 2 Slave. With the same orientation as in the RUA1 terminal diagram terminal diagram, 1 is the left and 2 the right terminal of the BLUEBUS pair. Numbers 1/2 indicate these positions, not the power supply +/−. With EPMB photocells, the BlueBUS pair does not require polarity.

RUA1 Master/Slave – connecting drives with ELDC, EPMB and EKS

  1. Set the opening directions of both opposing leaves and wire them according to the diagram with the power disconnected.
  2. Connect the receiver and shared safety/control devices to the Master.
  3. Switch on both motors. On the Slave, set level I, L8 = ON.
  4. Run device learning first on the Slave, then on the Master.
  5. Start travel learning on the Master and check that both leaves move together and that all safety devices work.

FLASH, S.C.A., the STOP safety edge and P.P. can be connected independently to the Slave. A P.P. command on the Slave opens only its own leaf fully; OPEN/CLOSE are not used on the Slave. Most settings are controlled by the Master. Sensitivity, force, S.C.A. output, Peak and error history are also assessed for the specific second drive.

Power supply for external accessories

The auxiliary power output from RUA1 is 24 V DC, −30% / +50%, 100 mA maximum total. For a nominal 24 V supply, this corresponds to approximately 16.8–36 V; the connected module must support this range. The power supply and command contact are two separate pairs of wires.

PurposeRUA1 terminalAccessory terminal
Power supply negative −Right-hand STOP terminal in the orientation shown in the image below− / GND device power supply
Power supply positive +Left P.P. terminal in the same orientation+ / V+ device power supply
Step-by-step commandBoth P.P. terminalsVoltage-free COM and NO relay; no polarity

RUA1 – auxiliary power supply: right STOP negative, left P.P. positive

For higher current draw, an unsuitable voltage range, or start-up surges, use a separate power supply appropriate for the module and connect only an isolated voltage-free contact to P.P. Do not use the FLASH output or BlueBUS as a substitute for the auxiliary power supply.

Gate held open and timer

A voltage-free P.P. command lasting longer than 2 s opens the gate and keeps it open for as long as the command is active, for example when triggered by a timer switch. This function is not used in mode II/L2, value L5 “Shared entrance 2”. If a continuous command is received unexpectedly, check the timer and the relevant input.

Emergency movement when a safety device fails

Only under direct supervision and with the safety path completely clear: after the first command is rejected due to a safety fault, issue the command again within 3 s and hold it. After about 2 s, the gate moves while you hold the command; releasing it stops the gate. This is a temporary emergency mode, not a substitute for repair. Never bypass a safety device for continuous operation.

Maintenance and servicing

Perform maintenance at least every 6 months or after 20,000 operations, whichever comes first. Disconnect the power supply, check the fixings, corrosion, wear on the wheel and rack, the guides and free movement; clean the photocells and repeat the safety tests. The service indicator does not replace regular maintenance.

Maintenance reminder

The threshold is set by II/L7. To also have S.C.A. indicate the need for maintenance, set II/L4 = L7.

Counter statusFLASH / maintenance indicator
Below 80% of the thresholdFLASH flashes normally; the indicator lights for 2 s at the start of opening.
81–100% of the thresholdFLASH stays on for 2 s at the start, then flashes normally; the indicator flashes during operation.
Above 100% of the thresholdFLASH stays on for 2 s at both the start and end; the indicator flashes continuously.

Checking the number of operations

  1. Enter SET programming for about 3 s; release when L1 flashes.
  2. Use OPEN/CLOSE to select input L7.
  3. Hold SET and wait about 3 s for the LED showing the current value to light up.
  4. While holding SET, briefly press and release OPEN + CLOSE together.
  5. The number of flashes of the value LED represents the consumed tens of percent of the threshold; no flashes means the value is below 10%. Release SET.

Resetting the service counter

  1. After completing maintenance, select II/L7 using the same procedure.
  2. Hold SET and wait about 3 s for the value LED to light up.
  3. While continuing to hold SET, press OPEN + CLOSE for at least 5 s, then release both buttons.
  4. Rapid flashing confirms the reset; release SET and wait for programming to end.

This procedure resets the service counter. It does not delete transmitters, replace travel learning, or perform a full control unit reset. If there is an electronics fault, do not try an unverified button combination; follow the diagnostics and servicing instructions for the specific RUA1.

Troubleshooting

Before working on an open drive unit, disconnect the power supply. Measurements on mains or live terminals must be performed by a qualified person. Contact our technical support team with the motor model, board designation, and number of flashes.

By fault symptom

SymptomWhat to check
The remote control does not light upCheck the battery and contacts in the remote control according to its instructions.
The remote control lights up, but the gate does not respondReceiver compatibility and memory; pairing. Also test the button or P.P. input to distinguish a radio fault from a drive fault.
BLUEBUS is offCheck the mains supply and fuses with the power safely disconnected; do not bypass safety devices.
Command is not registeredWhen the BLUEBUS input changes, it flashes rapidly twice; an NO command on P.P./OPEN/CLOSE should light the corresponding LED. Check the contact and cable.
The gate starts moving, stops, or reversesFirst, manually check for friction, and inspect the track, carriages, ice, rack clearance, and stops. Then check the force/sensitivity setting; changing it requires a new impact force measurement.
Warning light does not workCheck FLASH, wiring, short circuits, and warning light compatibility. While flashing, the measured voltage may fluctuate at around 10–30 V DC; it is not a constant 24 V power supply.
S.C.A. does not workFirst check mode II/L4, then the load (up to 4 W), cable, and output (approximately 24 V DC).
The limit switch does not stop movementCheck the mounting and position of the electromechanical limit switch brackets. If the direction is wrong, stop and correct the direction selector.

Warning light diagnostics

During normal movement, the flashing is regular. An error code consists of a series of flashes, a 1 s pause, and the same series again; count the flashes in one series.

FlashesMeaning / solution
1BlueBUS
Check the devices, wiring, and addresses. Repeat learning after a repair or an intentional change to the setup, not to mask a faulty safety device.
2Photocell
A normal response when the beam is interrupted in the protected direction. With the path clear, check cleanliness, alignment, and addresses.
3Resistance / obstacle detection
Remove the obstacle and eliminate mechanical resistance. Do not increase Force or Peak without checking the gate and carrying out a subsequent safety test.
4STOP
The learned status has changed. Check the safety edge, contacts, and wiring; do not bypass the safety device.
5Internal parameters
Wait 30 s and repeat the command. If the fault recurs, have the RUA1 serviced.
6Operation limit / temperature
Wait a few minutes and allow the motor to cool down. Check the required operating frequency and mechanical resistance.
7Electronic circuits
Disconnect the power supply for a few seconds and try again. If the fault persists, contact service.
8Continuous command
Check the timer or a permanently active control input. This may be expected if the gate is intentionally being held open.

Control unit LED

BLUEBUS, STOP, P.P., OPEN, CLOSE

LED / statusMeaning
BLUEBUS offNo power supply or fault. Check the mains supply and fuses.
BLUEBUS continuously litSerious fault. Safely disconnect the power supply and check the wiring; if the fault recurs, contact service.
BLUEBUS flashes once per secondNormal operation.
BLUEBUS flashes twice rapidlyInput status changed or a command was received.
BLUEBUS series of flashesCode as in the flashing light diagnostics.
STOP litCorrect STOP status learned.
STOP offSTOP status changed or learning is incomplete; check the safety device.
P.P./OPEN/CLOSE litThe corresponding volt-free contact is active.
P.P./OPEN/CLOSE offThe corresponding contact is not active.

LEDs L1–L8

During normal operation, a lit LED indicates that a Level I function is enabled; an unlit LED indicates that it is disabled. L1 automatic closing, L2 closing after photocell activation, L3 always close, L4 slowdown, L5 Peak, L6 pre-flashing, L7 CLOSE = partial opening, L8 Slave. A single flashing LED may indicate programming; L1/L2 together indicate a request to learn devices, and L3/L4 together indicate travel learning.

Reading the error history

  1. Press SET for approximately 3 seconds, then release when L1 flashes; use OPEN/CLOSE to select entry L8.
  2. Hold SET; after approximately 3 seconds, the LEDs for manoeuvres during which an error was recorded will light up.
  3. While holding SET, use OPEN/CLOSE to select a specific record. L1 is the newest record; L8 is the eighth and oldest.
  4. Read the number of flashes for the selected record using the flashing light diagnostics. Release SET and wait for programming to finish.

Manual release of NICE RUN2500

Stop the gate, disconnect the electrical power supply, and secure the gate leaf to prevent uncontrolled movement. Only release the drive when the gate is stationary.

NICE RUN – original manual release procedure

  1. Slide the lock cover aside.
  2. Insert the key and turn it clockwise.
  3. Pull out the release lever.
  4. Move the gate leaf manually and under control.

To re-engage the drive, carry out the procedure in reverse order. Check that the gearbox has re-engaged before restoring the power supply. Keep the key accessible even when the entrance is closed.

NICE RUN2500 technical specifications

Specifications for the 230 V RUN2500 version. Always check the electrical ratings and version against the rating plate on the supplied motor. Rated specifications apply at approximately 20 °C.

ParameterValue
ModelRUN2500 – electromechanical limit switch
Type and controlElectromechanical sliding gate operator, RUA1; plug-in radio receiver not included with the standalone motor.
Motor and mains supply230 V AC, 50/60 Hz; tolerance as specified on the rating plate of the supplied version.
Max. weight / length

2,500 kg / 18 m; other conditions and available cycles as shown in the suitability tables.

Pinion18 teeth, module 4, pitch approximately 12.6 mm; pitch diameter 60 mm.
Peak torque / force

50 Nm / 1,390 N

Rated torque / force

30 Nm / 830 N

No-load speed0.17 m/s at 50 Hz, approximately 10.2 m/min.
Rated speed0.14 m/s at 50 Hz, approximately 8.4 m/min.
Rated frequency with a 15 m gate leaf

15 cycles/h at rated torque and with a 15 m gate leaf. Additional limits apply depending on length, weight and temperature; this is not the number of cycles that can be run without a break.

Continuous operation

Maximum 60 min at rated torque, subject to additional cycle limits. At 50 °C, maximum 10 min; with a 15 m gate leaf, maximum 7 cycles/h.

Power consumption / current

Starting: 870 W / 3.8 A; rated: 600 W / 2.7 A.

Electrical protectionClass I – PE protective earthing.
FLASHOne or two flashing lights, each with a 12 V / 21 W lamp; not intended as a continuous auxiliary power supply.
S.C.A.24 V DC, max. 4 W, voltage −30% / +50%.
Auxiliary power supply24 V DC, −30% / +50%, max. 100 mA total; observe the correct STOP/P.P. polarity.
BlueBUSMax. 15 load units; photocells are polarity-insensitive.
STOPVolt-free NO/NC contact or 8.2 kΩ resistor; learned status.
P.P., OPEN, CLOSEVolt-free NO contacts.
Radio / antennaSM connector; receiver selected separately. 52 Ω antenna input, RG58 or similar coaxial cable.
Programming8 ON/OFF functions and 8 parameters; Levels I and II.
LearningBlueBUS devices, STOP input type, and travel length with slowdown/partial-opening points.
Operating temperature−20 to +50 °C
Protection ratingIP44
Unsuitable environmentsAcidic, saline or potentially explosive atmospheres.
Overall dimensions400 × 255 × 390 mm according to the technical table; mounting dimensions are shown in the original drawing below.
Motor weight24.5 kg
Service lifeApproximately 150,000–450,000 cycles, depending on the sum of the indices and the graph; not guaranteed.

Operator dimensions

NICE RUN2500 – original dimensional drawing

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE Run RUN2500 – standalone operator for sliding gates (A)

Product: NICE Run RUN2500 – standalone operator for sliding gates (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.