NICE Hyppo HY7024 - swing gate operator for a gate leaf up to 3 m/350 kg
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€553.27 including VAT
| Weight |
|---|
| 13 kg |
Description of NICE Hyppo HY7024 - swing gate operator for a gate leaf up to 3 m/350 kg
Backup in the event of a power outage: for the control unit MC824HR30 use NICE PSS324. With the older PS324 you need CABLA11 cable and Standby must be switched off. Backup connection.
NICE HYPPO HY7024 – articulated-arm swing gate operator
NICE HYPPO HY7024 is a standalone electromechanical motor for one gate leaf. It has a 24 V DC, articulated arm and is non-reversible. It monitors the gate leaf position using a magnetic encoder. It requires a separate control unit and safety accessories; in the event of a power failure, it can be released with a key.
Disconnect the power supply and any backup power before opening the motor or control unit. When operating manually, secure the gate leaf to prevent unintended movement.
When to choose this operator
HYPPO is suitable for swing gates with the articulated arm installed on the inside. The key factors are the gate leaf’s length and weight, resistance to movement, hinge position and the space required for the arm’s full range of motion.
| Maximum gate leaf length | 3 m; the permissible weight decreases as the length increases. |
|---|---|
| Weight according to the graph | For a gate leaf of 2 m the lower curve in the graph is below 350 kg; for 3 m, below 200 kg. Assess the specific weight using the relevant curve and the gate conditions. |
| Duty cycle | 80%; also suitable for more intensive use. |
The 3 m length and 350 kg weight limits do not apply simultaneously. The limits apply to one motor and one gate leaf. The gate’s height and shape, solid infill and strong winds can significantly reduce these values. A duty cycle expressed as a percentage is not the number of cycles per hour or continuous operation.
The horizontal axis shows length in metres; the vertical axis shows weight in kilograms. For HY7024, use only the lower permissible area of the graph.
Compatible accessories
Choose accessories according to the installed control unit, connectors and voltage. The following wiring and procedures apply to the MC824HR30.
| What | Why | Type |
|---|---|---|
| Control unit | Controls one or two motors and safety devices. | |
| Warning light | Warns that the gate is moving and can house an antenna. |
|
| Photocells | They monitor the gate area; the response depends on their position. | |
| Backup battery | Operation during a mains power failure. |
|
| Wireless photocells | A solution that avoids running cables to the photocells. |
|
| Receiver | Receives commands from remote controls; one receiver is fitted in the SM. |
|
| Transmitter | Remote control, depending on the installed receiver. | |
| Antenna | Helps improve the remote control's range. |
|
| Keypad | Send a command using a code, without a remote control. |
|
| Key switch | Send a command using a key from a fixed location. |
|
| Card reader | Control using an assigned card or key fob. |
|
| Electric lock | Additional gate-leaf locking, synchronised with the control system. |
|
| Extended arm | Greater reach for non-standard mounting configurations. | |
| External release | Manual access during a power outage when there is no other entrance. |
|
| Wi-Fi / GSM control | Remote command via a potential-free contact. |
|
| Programming and integration | Advanced configuration and diagnostics. |
|
FT210B not suitable for MC800 or MC824H: they require different FT A / FT B / FT C addresses. Select the compatible photocells listed above.
Standalone motor and control unit
The offer is for one HYPPO HY7024 motor with articulated arm. The standalone motor does not include a control unit. For a double-leaf gate, you need two compatible motors; this does not increase the limit for a single leaf. Choose the control unit, photocells, beacon, receiver and remote controls to suit the setup.
| Configuration | Control unit | Important difference |
|---|---|---|
| HY7024 | MC824HR30 | 24 V DC with encoder. The control unit is powered by 230 V AC. MC824L is not a replacement for HY7024. |
For an existing gate, follow the instructions for the installed control board. The manual for the current MC800 does not apply to the old A60, and MC824HR30 procedures do not automatically carry over to a different MC824H generation.
Installing the articulated-arm operator
Before installation
- The gate leaf must move smoothly by hand along its entire travel path. Check the hinges, the strength of the gate leaf, and the load-bearing capacity of the mounting points.
- Install solid mechanical stops for the open and closed positions to limit travel and allow the control unit to learn the limits.
- Leave enough clearance for the motor body, the full movement of the arm, and the release handle. Assess potential pinch and trapping points and plan suitable safeguards.
- Fit the mounting plate to the post and the front bracket to the gate leaf. The mounting dimensions and the strength of the mounting surface are critical.
Mounting dimensions A and B
Measure dimensions A and B as shown in the diagram. The table is for the standard HY7024 articulated arm; it shows the opening angle for each specific pair of dimensions, in millimetres.
| B | A = 110 mm | A = 130 mm | A = 150 mm |
|---|---|---|---|
| 90 mm | 85° | 98° | 104° |
| 110 mm | 91° | 97° | 103° |
| 150 mm | 110° | 120° | 115° |
| 200 mm | 105° | 110° | 115° |
| 250 mm | 105° | 110° | 110° |
| 300 mm | 100° | 105° | 105° |
| 350 mm | 95° | 100° | 96° |
The angle is determined by the geometry, not by an arbitrary setting on the control unit. Before final fixing, disengage the motor and check the full travel of the gate leaf and arm. The stops must prevent movement beyond the safe operating area.
Extended arm HYA12
NICE HYA12 extended articulated arm provides greater reach. The diagram also defines dimension D. The maximum A/B/D values are installation limits, not recommended post dimensions. Do not automatically apply the standard-arm angle table to the HYA12.
| Dimension | Standard arm | HYA12 |
|---|---|---|
| A max. | 150 mm | 400 mm |
| B max. | 350 mm | 450 mm |
| D max. | 450 mm | 800 mm |
Mounting the plate and bracket
- Determine whether this is a left- or right-hand installation when viewed from inside the property. The same model can be configured for either side by changing the plate position and assembling the arm accordingly.
- Secure the mounting plate A to the solid post surface and the bracket B to a solid part of the gate leaf. Here, A/B identify the parts, not the mounting dimensions in the previous table.
- Bolt the motor to the plate. Correct minor alignment deviations using the elongated mounting holes.
- Assemble the arm for the selected side. Before assembly, lubricate the screws as specified in the installation instructions, then fit the washers and fasteners.
- With the motor disengaged, move the gate leaf by hand as far as both stops; then fully tighten the fasteners.
Left-hand installation, viewed from inside:
Right-hand installation, viewed from inside:
Cover and mechanism protection
After adjustment, fit the cover and release handle, and secure them with screws. Check the cable glands and ensure the cover is closed. Water must not enter the operator or control unit; protect the cables from the arm and the moving gate leaf.
Manual release
- Stop the automation, disconnect the power supply, and secure the gate leaf against unintended movement.
- Slide the lock cover upwards. Insert the key and turn it clockwise.
- Turn the release handle as shown; then move the gate leaf by hand.
- Before automatic operation, return the mechanism to the locked position with the handle vertical. Check that the drive is secured, remove the key, and close the lock cover.
If you have no other way onto the property, plan for access during installation: NICE KIO with KA1 cable allows manual release from outside. Install and test the assembly before putting the gate into operation.
Wiring and electrical connections
Route and protect mains cables, motor wires, and low-voltage signals according to their voltage and environment. The power supply to the control unit consists of L, N, and PE; protect it with suitable overcurrent protection and a device for complete disconnection. Secure cables with cable glands and strain relief.
| Circuit | Cable | Use |
|---|---|---|
| Power supply to control unit | 3 × 1.5 mm² | Up to 30 m; L, N, and PE. For longer runs, use 3 × 2.5 mm² and protective earthing at the automation unit as specified in the control unit manual. |
| Motor | 3 × 1.5 mm² | Up to 10 m; dedicated motor circuit. |
| Encoder | 2 × 1 mm² | Up to 10 m, non-polarized; connect to the corresponding motor. |
| BlueBUS | 2 × 0.5 mm² | Up to 20 m; for runs over 20 m and up to 40 m, use 2 × 1 mm². |
| Warning light | 2 × 0.5 mm² | Up to 20 m, low-voltage FLASH. |
| Electric lock | 2 × 1 mm² | Up to 10 m; output 12 V AC / max. 15 VA. |
| Key switch | 4 × 0.5 mm² | Up to 50 m; alternatively, two 2 × 0.5 mm² cables. |
| Antenna | RG58 | Up to 20 m; less than 5 m is recommended. |
Check the cable cross-section and route against the cable lengths and the manual for the installed control unit.
Motor and control unit wiring
HY7024 must be connected to the 24 V DC motor output on the MC824H, not to the 230 V mains. The procedure below is for the MC824HR30 with the MCA1R30 board. The two encoder wires are non-polarized; connect them to the corresponding ENC terminal. The MC824L uses different motors.
| Single leaf | Motor to M2, encoder to ENC2; M1 and ENC1 remain unused. |
|---|---|
| Two leaves | M2 opens first; M1 closes first. The M1 encoder connects to ENC1, and the M2 encoder to ENC2. |
| Motor selector | Before teaching the positions, set DIP 1 = ON; DIP 2–12 = OFF for HY7024. Do not use any other setting. |
Use the model-specific setting for HY7024; the programmer may display this group as MB4024. The important thing is to set the switches correctly for HY7024.
Accessory terminals and polarity
| Auxiliary power supply | Left terminal in the SbS pair = +; right terminal in the STOP pair = −, as shown in the detail below. 24 V DC −30% / +50%, total max. 200 mA. Voltage remains present in Standby. These are the indicated power supply terminals, not arbitrary signal contacts. |
|---|---|
| BlueBUS | Two parallel wires carry both power and data; no +/− polarity. |
| ENC1 / ENC2 | Encoders for the corresponding motors; non-polarized. |
| FLASH | 12 V DC warning light, max. 21 W; for example, ELDC. Before wiring, check the +/− markings on the specific output and warning light. |
| ELS | Electric lock 12 V AC, max. 15 VA; AC has no +/− polarity. |
| OGI | Open gate indicator: 24 V DC, max. 4 W. The mode depends on the settings; follow the markings for the installed output. |
| SbS / Open / Close | Potential-free NO contacts for the corresponding pairs: step-by-step, open only, or close only. The contacts are non-polarized; do not apply an external voltage to them. |
| STOP | Learned safety input: NO, NC, or 8.2 kΩ. Potential-free contacts are non-polarized; wiring must match the safety devices. |
For a different board or terminal layout, refer to the manual for the installed unit. Detailed MC824HR30 wiring.
Backup during a power failure
The MC824HR30 supports PSS324. Disconnect both the mains supply and the battery before connecting, and use the designated connector. If retaining the older PS324, you need the CABLA11 cable and Standby must be OFF. The number of operating cycles depends on the battery charge and the gate load. Backup does not replace correct manual release. Complete backup connection procedure.
Photocells and safety inputs
Position the photocells according to the movement of the gate leaves and the gate’s hazards. Align TX/RX correctly. Protecting the passage does not replace protection at pinch points around the hinge and arm.
For photocells, the MC824H uses BlueBUS. EPMB, EPLB, EPSB, EPMORB and F210B connect them in parallel using two wires, with no polarity. The TX/RX units in each pair must have the same address, and each pair must have an address different from the others. After changing the devices, repeat the learning procedure.
PHOTO/PHOTO II protect during closing; PHOTO 1/PHOTO 1 II activate during both opening and closing. PHOTO 2/PHOTO 2 II protect during opening. PHOTO 3 is not permitted. The exact jumpers and responses are shown in the addressing table.
Test each pair during opening and closing, and test STOP and any safety edge. Do not bypass a safety device to make the gate move.
Initial start-up and learning
Perform these steps after completing the mechanical and electrical checks. Set the motor to automatic mode, and check the stops, clear travel path, and M1/M2. Be ready to stop the gate during its first movement.
On the MCA1R30, set DIP 1 to ON and all other switches to OFF for the HY7024, then connect the encoder.
After switching on the power, BlueBUS must flash approximately once per second, the LEDs on the connected BlueBUS photocell TX/RX units must flash, and the FLASH beacon must be off. If any check fails, disconnect the power supply and any backup supply, then check the wiring before proceeding.
1. Device recognition
- Press and hold Open ▲ + Stop/Set.
- Release both buttons when L1/L2 start flashing rapidly, after approximately 3 seconds.
- Wait for the process to finish. Successful completion: STOP is lit and L1/L2 are off. L3/L4 may flash to indicate that position learning is required.
Repeat after adding or removing a BlueBUS/STOP device. Run the learning procedure even if no accessories are connected.
2. Automatic position learning
- Press and hold Stop/Set + Close ▼.
- Release the buttons when L3/L4 start flashing rapidly, after approximately 5 seconds.
- Watch for the following: M1 closes slowly to its stop, M2 closes slowly to its stop, both motors open slowly to their stops, and both motors close rapidly. With a single motor, only M2 moves.
- Successful completion is confirmed when L3/L4.
If a motor opens instead of closing during the initial closing movements, stop the learning procedure using Open ▲ or Close ▼. Disconnect the power supply and any backup supply, then correct the direction of the relevant motor by swapping the two outer motor wires as shown in the MC824H diagram; do not change the encoder wires. If the sequence is incorrect, correct the M1/M2 assignment, including ENC1/ENC2. Restart the learning procedure from the beginning. Activation of a photocell or STOP interrupts the procedure and L1 flashes; resolve the cause and repeat the learning procedure.
3. Testing and handover
Test full opening and closing cycles, the stops, deceleration, gate-leaf overlap, and manual release. Test every safety device, stopping, and reversal when an obstacle is encountered. Measure the forces and assess the complete installation. Do not set a high force to compensate for a gate that is binding. The user must receive the manual and know how to release the drive safely.
Manual and mixed learning: detailed control unit procedure. Run automatic learning before mixed learning.
Settings and remote controls
Set automatic closing, pause time, step-by-step operation, deceleration, and force according to the gate. Repeat the tests after changing the force or safety functions. For the full ranges, LEDs, and factory settings, see the control unit programming tables.
Receiver, remote control, and antenna
The standalone motor does not have a built-in radio receiver. An SM receiver is installed in the control unit. NICE OXIBD also supports bidirectional ON3EBD; OXILR use with ON3ELR. With the older OXI select transmitters according to the stored coding. The same frequency alone does not guarantee compatibility.
Connect the coaxial cable according to the receiver: directly to the receiver for OXIBD, and as shown in the control unit diagram for OXI. Pairing and deleting remote controls. Erasing the radio memory does not reset the board or perform position learning.
Troubleshooting
| Symptom | What to check |
|---|---|
| Gate does not move | Power supply, drive release engaged, and STOP. Check the power supply and fuses with the power disconnected. |
| Motor runs, but the gate leaf does not move | Check that the gear mechanism is engaged and the arm is secured; return the release mechanism to the locked position. |
| Gate stops or reverses | First check manual movement and the arm’s clearance, then the photocells, STOP, and stops. Do not increase the force without identifying the cause. |
| Learning does not complete | Motor sequence and direction, stops, and safety devices. For the HY7024, also check DIP 1 and the encoders. |
| The remote control doesn’t work, but the button does | Battery, coding, programming the transmitter into the receiver, and the antenna. |
| Fault after changing the photocells | Addresses and cables, then repeat device recognition. |
Beacon and LED flash counts: troubleshooting and repairs. Record the settings before resetting. Resetting the control board, erasing the receiver, and programming it again are separate procedures; refer to the manual for the installed unit.
Inspection and maintenance
Have the entire assembly inspected at least every six months; more frequently in intensive use or harsh environments, in line with the maintenance schedule. Check the hinges, fasteners, arm play, stops, manual release, cable glands, and cables. Test the photocells and STOP input, and record the inspection.
Keep clear of the gate leaf and articulated arm while they are moving. Do not let children play near the gate, and keep the remote controls out of their reach. Keep the gate area clear. Clean surfaces and photocell lenses without using harsh cleaning products. Do not rinse the motor with a pressure washer. After working on the mechanism, electrical circuits, or safety settings, repeat the functional and safety tests. If the arm is damaged, makes unusual noises, or moves on its own, take the automation system out of service and arrange a repair.
NICE HYPPO HY7024 technical specifications
| Type | Non-reversible electromechanical articulated-arm operator for one gate leaf. |
|---|---|
| Motor | 24 V DC |
| Current | 5 A |
| Power consumption | 120 W |
| Torque | 250 Nm |
| Rotation speed | 2 rpm |
| Duty cycle | 80 % |
| Position sensing | Magnetic encoder |
| Protection rating | IP43 |
| Operating temperature | −20 to +50 °C |
| Dimensions | 350 × 165 × 242 mm (width × depth × overall height) |
| Weight | 13 kg |
| Gate leaf limits | Up to 3 m; refer to the limit graph. |
The overall height of 242 mm includes the plate beneath the operator body; the drawing shows the cover height as 152 mm.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]