Manual for a cantilever sliding gate from 7 to 10 m

Technical guide · DIY construction · cantilever sliding gate

A practical guide for gates with a clear opening width of 7.0 to 10.0 m: two concrete foundations, cabling, carriages, guide system, drive, wiring and technical drawings.

Overview of a cantilever sliding gate with the opening, load-bearing C-section, carriages, counterbalance and drive
Main components of a cantilever sliding gate. Click to open the drawing at full resolution.

Cantilever sliding gate for a 7.0 to 10.0 m opening

For wider openings, the gate leaf length and weight, counterbalance, load-bearing C-section, number of carriage rollers, infill, guide system, foundations and drive must be properly matched. The guide below starts with the construction work and continues in the order in which the individual components are actually prepared.

What to measure and choose before building

Space

  • clear opening width (ŠP),
  • the side and direction in which the gate slides open,
  • clear space for the entire gate leaf, including the counterbalance,
  • ground levels along the entire travel path.

Structure

  • frame height and infill type,
  • dead weight, infill weight and wind load,
  • C-section and carriages designed for the specific load.

Foundations

  • space for two separate foundations,
  • spacing X based on the gate width and carriage type,
  • positions of the mounting plates and conduits.

Controls

  • manual or motorised operation,
  • positions of the drive, photocells and warning light,
  • power supply and control method.

1. Concrete foundations and mounting plate positioning

The source drawing for gates wider than 6.5 m uses two separate foundations. The foundation closer to the opening is 1 000 mm long, the second is 1 400 mm long, and the gap between them is X. The total length of the assembly is therefore 2 400 + X.

Minimum width of each foundation: 500 mm.
Minimum depth: 800 mm. Recommended distance Y from the wall: 50 to 100 mm.

Plan view showing the position of the two concrete foundations and carriages

Plan view of two concrete foundations for a cantilever gate over 6.5 metres wide, with dimensions of 1000, X and 1400 millimetres and mounting plates
Plan view of the foundations, spacing X and mounting plates. Click to open the complete source page.

Concrete foundations – views A and B

Views A and B of two concrete foundations, showing the minimum width of 500 millimetres, depth of 800 millimetres and mounting plate positions
Views A and B, including ground level, foundation dimensions and a warning to install the cabling before pouring the concrete.

Foundation spacing X by clear opening width

Dimension X in millimetres by carriage type

Clear opening width Carriage with 8 rollers Carriage with 10 rollers
7 000 mm 950 mm 850 mm
7 500 mm 1 150 mm 1 050 mm
8 000 mm 1 350 mm 1 250 mm
8 500 mm 1 550 mm 1 450 mm
9 000 mm 1 750 mm 1 650 mm
9 500 mm 2 050 mm 1 950 mm
10 000 mm 2 250 mm 2 150 mm

Bold values correspond to the recommended 10-roller version in the source drawing. Always read dimension X for the carriage actually being used.

Mounting plate (MD) positioning

Carriage type Dimension Z Mounting plate MD
8 rollers 240 mm 120 × 180 mm
10 rollers 310 mm 120 × 300 mm

Mounting plate holes must be at least Ø 17 mm for M16 threads. Set the height of the foundation top edge according to the required gate clearance above ground and the carriages’ height adjustment range.

2. Preparing cables and conduits before pouring the concrete

Install the conduits and cable outlets before pouring the concrete. The diagram below retains the complete original wiring description, including the power supply, photocells, warning light, antenna cable and dimension notes.

Recommended cable runs from the source material

Label Connection Cable
I 230 V drive power supply 1 × 3 × 1.5 mm²
II Left photocell 1 × 2 × 0.5 mm²
III Right photocell 1 × 2 × 0.5 mm²
IV Warning light and antenna 1 × 2 × 0.5 mm² + shielded RG58 / 50 Ω coaxial cable
Complete original cabling preparation page for NICE Robus RBS 600 and 1000 and RUN 1800 or 2500 drives, including all annotations and the table
Complete cabling preparation page, uncropped. Click to open at full resolution.

3. Gate guidance, carriages and height above ground

The gate leaf must be guided from above or from the side, and the carriages must match the selected C-section. Height H, measured from the top of the foundation to the bottom of the C-section, is determined by the carriages used and their adjustment range.

Top and side guidance for a cantilever gate, carriage height dimensions and frequently asked questions from the source material
Guidance methods and determining height H. Click to open the original page at full resolution.

Height H by C-section and number of rollers

C-section 3 rollers 5 rollers 8 rollers 10 rollers
70 × 70 × 4 mm 78–98 mm 95–115 mm 90–110 mm —
80 × 80 × 5 mm 73–93 mm 90–110 mm 85–105 mm 93–109 mm

Recommended carriages for gates over 6.5 m

Below are suitable options for larger C-sections and heavier loads. Choose the final carriage based on the specific profile, opening width, total weight, infill and gate construction.

View all carriage types

C-sections for larger cantilever gates

The source drawings use an 80 × 80 × 5 mm profile. More robust systems are also available for heavier loads; choose the specific size only after checking the weight, infill, wind load and compatible carriages.

View all C-sections

Source overview of CAIS C-sections for large and oversized gates, including sizes 73 × 61 × 3.5 and 95 × 86 × 5 millimetres
Examples of CAIS profiles for large and oversized gates from the source manual. The selection is not limited to these two sizes.

4. Drive and rack height

The drive mounting plate height X depends on carriage height H, C-section height A, the required clearance Y beneath the rack, and dimension N of the specific drive.

X = H + A + Y + 40 − N
Component Option Dimension
A – C-section height 70 × 70 × 4 mm 70 mm
80 × 80 × 5 mm 80 mm
N – drive pinion height ROAD 400 / ROBUS 400 85 mm
ROBUS 600 / ROBUS 1000 92 mm
RUN 1800P 109 mm
Calculation of the drive mounting plate and rack height using dimensions H, A, Y and N
Source drawing showing the drive and rack height, including the table and a calculation example.

5. Drive wiring diagrams

RBS600 and RBS800 belong to the new generation of NICE ROBUS drives. The older RB1000 and RUN1800 drive have their own wiring diagrams.

NICE ROBUS RBS600 and NICE ROBUS RBS800

NICE ROBUS RBS600 assembly (D) | NICE ROBUS RBS800 assembly (D)

Wiring diagram for NICE ROBUS RBS600 and RBS800, figure 33 from the installation manual.
Wiring diagram for NICE ROBUS RBS600 and RBS800, figure 33 from the installation manual.

RBS600 / RBS800 installation manual (PDF, page 16)

NICE ROBUS RB1000

NICE ROBUS RB1000 assembly (D)

Wiring diagram for the previous-generation NICE ROBUS RB1000, figure 7 from the installation manual.
Wiring diagram for the previous-generation NICE ROBUS RB1000, figure 7 from the installation manual.

RB1000 Installation Manual (PDF, page 12)

NICE RUN1800

NICE RUN1800 Assembly (D)

NICE RUN1800 uses a 230 V AC electric motor, while the ROBUS RBS600/RBS800 and older RB1000 have a 24 V DC motor. This is the main difference in the motor’s power supply. Both types of operators are connected to the 230 V mains.

RUA1 control unit has similar basic functions to the ROBUS. It supports automatic closing, partial opening, and connection of BlueBUS photocells. However, the terminal layout and specific wiring are different.

RUN1800 operator dimensions

400 × 255 × 390 mm (length × width × height) according to the manufacturer’s technical table.

NICE RUN1800 dimension drawing, figure 1 from the manufacturer’s manual. Dimensions are in millimetres.
NICE RUN1800 dimension drawing, figure 1 from the manufacturer’s manual. Dimensions are in millimetres.

The dimension drawing shows 400 × 253 × 387 mm, while the technical table in the same manual lists 400 × 255 × 390 mm.

Dimension drawing in the manual (PDF, page 4) | Technical data (PDF, page 24)

Connecting the RUA1 control unit

The RUN1800 diagram shows the original LUCYB, MOFB and MOSE accessories. This is not a depiction of the current kit.

Wiring of the RUA1 control unit for the NICE RUN1800 operator, including the mains cable and cable routing, figures 14 to 16 from the manufacturer’s manual.
Wiring of the RUA1 control unit for the NICE RUN1800 operator, including the mains cable and cable routing, figures 14 to 16 from the manufacturer’s manual.

RUN1800 / RUN2500 Installation Manual (PDF, page 9)

6. Summary table of dimensions and weights

Applies to the drawings below. The dimensions, net weight, and maximum loads apply to the specific assemblies shown in these drawings.

Dimensions and weights for the drawings below

Clear opening width Overall gate length Gate net weight Max. load per metre Max. infill weight
7.0 m 10.0 m 220 kg 50 kg/m 360 kg
7.5 m 10.7 m 250 kg 50 kg/m 385 kg
8.0 m 11.4 m 265 kg 35 kg/m 285 kg
8.5 m 12.1 m 305 kg 35 kg/m 305 kg
9.0 m 12.7 m 320 kg 35 kg/m 320 kg
9.5 m 13.4 m 385 kg 35 kg/m 340 kg
10.0 m 14.1 m 405 kg 25 kg/m 255 kg

Comparison of box sections with 2, 3 and 4 mm wall thickness

For the same outside dimensions, a thicker-walled box section weighs more. The following table compares the weight of the frame box sections and lower reinforcement alone based on the material quantities specified in the drawings. It excludes the 80 × 80 × 5 mm load-bearing C-channel, infill, hardware and other parts, so it is not the net weight of the complete gate shown in the table above.

Approximate box-section weight based on the bill of materials, excluding the C-channel and infill
Clear opening width Gate length 2 mm wall 3 mm wall 4 mm wall
7.0 m 10.0 m 111.8 kg 162.4 kg 208.8 kg
7.5 m 10.7 m 132.9 kg 193.1 kg 248.2 kg
8.0 m 11.4 m 142.3 kg 206.8 kg 265.8 kg
8.5 m 12.1 m 151.8 kg 220.5 kg 283.4 kg
9.0 m 12.7 m 178.0 kg 259.5 kg 335.5 kg
9.5 m 13.4 m 235.0 kg 342.5 kg 442.9 kg
10.0 m 14.1 m 249.2 kg 363.3 kg 469.7 kg

How to choose a frame: Size the gate to be as lightweight as possible while still providing sufficient strength and rigidity for the selected infill and wind loads. Using box sections of a different size or wall thickness will change the weight and performance of the frame. A heavier frame also puts more load on the C-channel and carriages. The permissible infill weight therefore cannot be increased simply in proportion to the wall thickness.

The maximum load and infill weight values in the first table do not automatically apply to the 3 mm and 4 mm wall variants. This comparison calculates the material weight, not a new gate load capacity.

Basis and weight calculation

The outer dimensions of the box sections and the material quantities remain the same in all three columns. Only the wall thickness changes. The quantities are taken from the bill of materials in the drawing, not from an exact cutting plan. The weight of the finished frame is also affected by offcuts, welds, surface treatment, and tolerances in the supplied profiles.

Clear opening 60 × 40 mm box section 80 × 40 mm box section
7.0 m 26 m 10 m
7.5 m 32 m 11 m
8.0 m 34 m 12 m
8.5 m 36 m 13 m
9.0 m 0 m 50 m
9.5 m 0 m 66 m
10.0 m 0 m 70 m

For a 9.0 m clear opening, the 80 × 40 mm box section totals 13 + 37 m; for 9.5 m, it totals 27 + 39 m; and for 10.0 m, 29 + 41 m. The total also includes the lower reinforcement shown in the drawing.

Outside dimensions 2 mm wall 3 mm wall 4 mm wall
60 × 40 mm 2.93 kg/m 4.25 kg/m 5.45 kg/m
80 × 40 mm 3.56 kg/m 5.19 kg/m 6.71 kg/m

Calculation: weight = length of 60 × 40 box section × its weight per metre + length of 80 × 40 box section × its weight per metre. For example, for a 7.0 m clear opening and a 3 mm wall: 26 × 4.25 + 10 × 5.19 = 162.4 kg of box sections.

The unit weights are from the SSAB dimensional table, verified on 11. 9. 2026. They serve as reference values for comparing weights, not as confirmation by the manufacturer or of the material grade used in the drawings.

Discrepancies in the drawings: For 8.5 m and 10.0 m clear openings, the lower box section is labelled differently in the cross-section than in the bill of materials: the cross-section specifies a 3 mm wall instead of 2 mm. For 9.5 m and 10.0 m clear openings, the frame cross-section shows 60 × 40 mm, while the elevation and bill of materials specify 80 × 40 mm. The comparison above explicitly uses the bill of materials. This does not amend the original drawings or their loads.

7. Technical drawings for each gate width

Each preview links to the full-resolution image. The summary table above also lists the key dimensions and weights as text; the drawings retain the frame layout, sections, dimensions, and carriage loads.

Overall length 10,000 mm, frame 7,200 mm, counterbalance 2,800 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for a 7,000 mm clear opening
Drawing for a 7.0 m clear opening – page 7 of the source manual.

Overall length 10,700 mm, frame 7,700 mm, counterbalance 3,000 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for a 7,500 mm clear opening
Drawing for a 7.5 m clear opening – page 8 of the source manual.

Overall length 11,400 mm, frame 8,200 mm, counterbalance 3,200 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for an 8,000 mm clear opening
Drawing for an 8.0 m clear opening – page 9 of the source manual.

Overall length 12,100 mm, frame 8,700 mm, counterbalance 3,400 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for an 8,500 mm clear opening
Drawing for an 8.5 m clear opening – page 10 of the source manual.

Overall length 12,700 mm, frame 9,200 mm, counterbalance 3,500 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for a 9,000 mm clear opening
Drawing for a 9.0 m clear opening – page 11 of the source manual.

Overall length 13,400 mm, frame 9,700 mm, counterbalance 3,700 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for a 9,500 mm clear opening
Drawing for a 9.5 m clear opening – page 12 of the source manual.

Overall length 14,100 mm, frame 10,200 mm, counterbalance 3,900 mm, frame height 1,500 mm, C-channel 80 × 80 × 5 mm.

Technical drawing of a cantilever gate for a 10,000 mm clear opening
Drawing for a 10.0 m clear opening – page 13 of the source manual.

8. Frequently asked questions and next steps

Does a gate with a clear opening over 6.5 m need two separate foundations?

This manual and its X-spacing table are based on the pair of foundations shown in the source drawing. Any change to the design concept must be assessed separately.

Is it enough to choose a carriage based on the C-channel size?

No. The profile size is only one of the criteria. The overall weight, load distribution, counterbalance, infill, wind, and operating frequency also matter.

Can I use any drive shown in the diagram?

No. The drive must be selected according to the leaf's weight and length, mechanical resistance, operating frequency, and required speed. The wiring diagram does not replace drive sizing.

What should be prepared before pouring the concrete?

The positions of the mounting plates, all conduits, the 230 V power supply, and wiring for the photocells, warning light, and any wired controls.

Where can I find the detailed force values for the carriages?

They are included directly in the technical drawing for each width. The summary table is deliberately simplified to five figures needed for an initial overview.

Didn't find the answer? Call us

Contact us. For gates over 6.5 m, we recommend checking the component selection before ordering and pouring the concrete.

Component kits for cantilever gates

CAIS components for large gates

Short on space for a gate?

If a large cantilever gate will not fit on your property, consider another solution too. A telescopic gate or another option may be a suitable compromise and help solve the lack of space on your property.

Telescopic cantilever gate

Short on space for a gate? See other options

Technical note: For gates of this size, have the final design, foundations, anchoring, infill, wind loading and safety features checked against the specific site conditions. Carry out the electrical installation in accordance with the manufacturer's current instructions and applicable regulations.


Prepared by Eng. Ján Kubíček.

Last updated: 16. 9. 2026.

Back to the beginning of the manual