NICE Run RUN1800 – standalone operator for sliding gates (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€727.70 including VAT
| Weight |
|---|
| 22 kg |
Description of NICE Run RUN1800 – standalone operator for sliding gates (A)
NICE RUN1800 is a standalone non-backdrivable sliding gate drive with a built-in control unit RUA1. Both the motor and mains supply are 230 V AC. It has an electromechanical limit switch. The limits for a single gate leaf are 1,800 kg and 15 m; suitability also depends on the resistance to movement and the required number of operating cycles.
The standalone motor is not a complete kit: choose the radio receiver, transmitters, photocells and rack to suit your gate's equipment. Installation manual PDF · Technical specifications
| Quick navigation | ||
|---|---|---|
| Selection and limits | Kits | Accessories |
| Installation | Wiring | Initial start-up |
| Programming | Faults | Maintenance |
| Manual release | Specifications | Manual PDF |
(Is this drive right for me?)
Compare with other drives:
This product—the standalone NICE Run RUN1800 sliding gate drive (our code NICE-RUN1800)—includes:
- electromechanical NICE Run RUN1800 drive with a capacity of 1,800 kg and a maximum gate-leaf length of 15 m, with an integrated (but removable) control unit RUA1 without radio receiver (if you want to operate the gate by remote control, you need to purchase a receiver separately, e.g. SMXI, or OXI).
- 2 × manual release keys for manual operation of the drive (required in the event of a power failure)
- drive mounting components, anchors and bracket, and stops for the drive's electromechanical limit switch
- installation manual
Discounted kits containing the drive NICE Run RUN1800:
| Drive kit with accessories » | Standalone drive | Drive kit with accessories and rack » |
|---|---|---|
|
1 × RUN1800 with RUA1, 1 pair of EPMB, 1 × ELDC, 1 × OXIBD and 1 × MYGO4. | Electromechanical limit switch. |
1 × RUN1800 with RUA1, 1 pair of EPMB, 1 × ELDC, 1 × OXIBD and 1 × MYGO4. Plus 4 m of rack LZ-1; check that the rack's length and load capacity are suitable for your gate. |
The drive is compact, safe and practical, making it ideal for both residential and commercial use. Impact-resistant housing, body made of aluminum alloy with an epoxy coating.
The drive is suitable for automating a sliding gate weighing up to 1,800 kg, with a leaf length of up to 15 m. These figures apply under the conditions specified by the manufacturer, including weather conditions, temperature variations, gate rigidity and, above all, smooth gate movement. These conditions cannot always be achieved or controlled, so we recommend using the NICE Run RUN1800 drive at up to 80% of these limits. See the Choosing a drive chapter for more information.
BlueBUS connects compatible photocells using a two-core cable. RUA1 supports seven basic protection addresses and a total load of up to 15 BlueBUS devices; one device does not necessarily mean one pair. Wiring and addressing photocells.
Temperature control protects the motor from overheating and reduces the permitted number of cycles at high temperatures. Optional motor heating for low temperatures is configured via a supported service interface; it does not replace clearing ice from the track.
Adjustable force, obstacle sensitivity, automatic closing pause and slowdown at the end of travel. Settings are listed in the programming tables.
Diagnostics using the warning beacon.
The gear module 4 is compatible with the toothed rack in our range.
Run 1800 drive functions "Slave unit" automatically synchronizes two motors. This means you can automate two sliding gates that move toward each other.
Safety is assessed for the complete, installed gate: mechanical safeguards, protection of hazardous areas, operation of photocells and safety edges, and impact-force measurements. The motor alone does not replace these tests.
Accessories compatible with the NICE Run RUN1800 drive
We also recommend purchasing compatible optional accessories for the drive, or choosing one of our pre-assembled discounted kits:
| What | Why | Type |
|---|---|---|
| Beacon | Signals gate movement and reports faults. Connects to FLASH; the antenna uses a separate coaxial cable. | |
| Photocells | Detect an obstruction in the beam; the response is determined by the pair address. They do not replace protection for all hazardous areas of the gate. |
BlueBUS wiring; FT210B for a moving safety edge. The TX and RX units in a pair use the same address. |
| Transmitter | Choose according to the coding and type of receiver installed. The same frequency alone does not guarantee compatibility; LoRa and two-way functions require a compatible receiver. | |
| Receiver | The radio receiver plugs into the SM connector; pairing depends on the receiver. Wi-Fi/GSM requires a supported interface or a volt-free P.P. contact. |
|
| Antenna |
For improved remote-control range. |
|
| Keypad | EDSWG requires a compatible radio receiver. For EDSB, the specific RUA1 version must support BlueBUS control devices; the bus alone does not confirm compatibility. | |
| Key switch |
Control the gate with a key using a switch connected to the drive by cable from any location. |
|
| Card readers | Use ETPB only after confirming that the installed RUA1 supports BlueBUS control devices. Connect a reader with a volt-free relay to P.P. and power it separately according to its current draw. |
|
| Gear rack | Required module 4 rack. Choose the material, fixing method and load capacity according to the gate weight; a nylon rack is not automatically suitable for the full maximum of 1,800 kg. | |
| Power failure | Use the manual release in the event of a power failure. Neither PS124 nor Solemyo is a direct 230 V backup for the RUN1800 motor with RUA1. |
NICE RUN1800 at a glance
Model RUN1800 has an electromechanical limit switch, a 230 V motor, and RUA1 control unit. The cover is impact-resistant, and the housing is made of an aluminum alloy. The receiver is selected separately; the SM connector and BlueBUS are two different interfaces.
When the motor is disengaged, the gate can be moved manually during a power outage. The gate must have reliable guidance, protection against derailment, and secure mechanical stops at both ends. The limit switch does not replace these stops.
Choosing the NICE RUN1800 operator
Weight and length alone are not enough. Measure the force required to start the gate moving and to keep it moving along its entire travel, including areas with higher friction. For the RUN1800, the starting force must be less than 555 N and the force required to keep the gate moving must be less than 280 N; these figures are half the available peak and rated forces, respectively. Also allow for conditions becoming more demanding in winter.
Limits and operating margin
| Parameter | Manufacturer's maximum | Our recommended guideline |
|---|---|---|
| Gate leaf length | 15 m | Up to 12 m |
| Total gate leaf weight | 1,800 kg | Up to 1,400 kg |
We retain the recommendation with a safety margin for typical selection purposes. This is not a separate manufacturer limit or confirmation that every gate of these dimensions is suitable. Also check mechanical resistance and operating load. What matters is the length and weight of the entire moving gate leaf, including its infill and any counterweight—not just the clear opening width.
How many cycles the operator can perform
One cycle is a complete opening and closing. First select the row based on the length; then multiply both cycle counts by the weight factor. Round the resulting whole number down. Higher temperatures and more demanding operation may reduce the number further.
| Gate leaf length | Max. cycles/hour | Max. consecutive cycles |
|---|---|---|
| Up to 6 m | 42 | 28 |
| Over 6 up to 9 m | 28 | 18 |
| Over 9 up to 12 m | 21 | 14 |
| Over 12 up to 15 m | 17 | 11 |
| Gate leaf weight | Available cycle factor |
|---|---|
| Up to 500 kg | 100% |
| Over 500 up to 900 kg | 80% |
| Over 900 up to 1,200 kg | 75% |
| Over 1,200 up to 1,500 kg | 60% |
| Over 1,500 up to 1,800 kg | 50% |
Example based on the tables: a 10 m / 1,300 kg gate leaf → 21 × 0.60 = 12.6 and 14 × 0.60 = 8.4. For planning, allow no more than 12 cycles/hour and 8 consecutive cycles, before applying any further reduction for temperature. A 60% factor means 60% of the available number, not a 60% reduction.
Estimated service life
Add the indices for weight, length, and any other relevant factors. Include other factors if the probability of their occurrence is greater than 10%. Find the total in the original chart. The estimated cycle count is not a service-life guarantee or a fixed number of years.
For example, 1,300 kg and 10 m gives 30% + 15% = 45%; if the photocells frequently interrupt operation, add 10%, for a total of 55%. The mere presence of photocells does not mean their index is automatically added. A total above 100% means the conditions are outside acceptable limits. The operator is not intended for use in acidic, saline, or explosive atmospheres; the salinity index shown does not authorize such use.
Installing the NICE RUN1800 operator
Anchor the operator to a firm, level base in an area that is not at risk of flooding. Determine the height based on the actual position of the rack and pinion. A cantilever gate may require a higher base or a suitably strong mounting bracket; its construction must safely support the load. The gate must not transfer its weight to the motor.
Wiring
Route the mains supply cable separately from low-voltage and signal cables. Select accessories, wiring, and protection according to the specific installation. Original typical setup:
|
|
| Purpose | Cable | Max. length |
|---|---|---|
| A – mains | 3 × 1.5 mm² | 30 m; over 30 m, at least 3 × 2.5 mm², subject to assessment of voltage drop and protection |
| B – warning light | 2 × 0.5 mm² | 20 m |
| B – antenna | RG58 coaxial cable | 20 m; under 5 m recommended |
| C – BlueBUS | 2 × 0.5 mm² | 30 m; for 30–50 m, 2 × 1 mm² |
| D – key switch | 2 cables, 2 × 0.5 mm² or 4 × 0.5 mm² | 50 m |
| E – fixed safety edges | 2 × 0.5 mm² | 20 m |
| F – moving safety edge | 2 × 0.5 mm² | 30 m; moving cable run or FT210B |
Foundation installation and inspection
- Before installation, disengage the drive and check that the gate moves smoothly by hand, the guide is aligned, the fixed end stops are secure, and the gate leaf is protected against lifting off.
- Prepare the cable conduits and the base plate with four anchors. Leave no more than 40 mm of thread exposed above the plate.
- Level the plate, set it into a solid foundation and allow the concrete to cure fully. Do not install the motor on a soft or unstable substrate.
- Secure the motor with four nuts and washers, adjust its position relative to the rack, then tighten the fasteners.
- Check the clearance, rack joints, gate guidance and switch positions along the entire travel path. Secure the cables so they cannot come loose and enter moving parts.
Gear rack and its end stop
The gate moves by transferring the drive pinion’s torque into linear motion via the rack-and-pinion mechanism on the drive gear rack. There are two most commonly used types of gear rack:
![]() |
Nylon rack (optionally with steel reinforcement) – attaches to the gate with self-tapping screws through the mounting holes. Ideal for relatively light and short gates. Friction between the steel pinion and nylon rack ensures quiet operation. |
![]() |
Steel rack – attaches to the gate by welding on threaded brackets, into which the rack is then screwed. Used for longer and heavier gates. Friction between the steel pinion and steel rack makes operation slightly noisier. |
It is essential that the drive pinion module is compatible with the gear rack module. Drive NICE Run RUN1800 has a tooth module of 4.
The drive detects the end position when opening and closing using end-stop brackets fitted to the gear rack:
| 1. Level the drive using the four adjustment points | 2. The gate and drive must both be level | 3. Leave a gap of approximately 1–2 mm between the gear rack and drive pinion so the weight of the gate is not transferred to the drive. |
![]() |
![]() |
![]() |
| 4. Tighten the drive mounting so it cannot shift when engaged | 5. Set the limit-switch brackets according to the instructions below. Fixed mechanical stops must remain at both ends of the travel path. |
|
![]() |
![]() |
Gap 1–2 mm must be maintained along the entire travel path. Align the rack with the pinion; move the gate manually to check for lateral deviations of no more than 5 mm and smooth transitions between rack sections. Tighten the motor securely once adjusted.
Setting the limit switches
The RUN1800 has an electromechanical limit switch. The brackets on the rack operate its lever.
- Move the gate leaf manually to the open position, stopping at least 2–3 cm before the fixed stop.
- Slide the bracket along the rack in the opening direction until it activates the limit switch.
- Move the bracket at least another 2 cm in the same direction and secure it.
- Set the bracket for the closed position in the same way.
- After engaging the gearbox and running the travel-learn procedure, check that the gate stops before both mechanical stops.
Wiring the NICE RUN1800 drive
Before opening the unit or connecting or disconnecting terminals, disconnect the mains supply and verify that it is de-energized. The mains supply is 230 V AC; accessory terminals have different voltages and functions.
230 V AC mains supply
| Terminal | Wire and function |
|---|---|
| L | Live wire; usually brown. |
| N | Neutral wire; usually blue. |
| PE / protective earth | Green-and-yellow protective conductor. Class I requires reliable protective earthing. |
Route the mains cable through the smaller cable gland and the other cables through the larger one. Fit the membranes tightly around the cables, restore the seal and secure the cables against pull-out. Leave the required slack inside, approximately 20–30 cm; cables must not obstruct the cover or moving parts.
RUA1 control unit terminals
| Terminal | Use, voltage and polarity |
|---|---|
| FLASH – warning light | For the current setup ELDC LED warning light (12–36 V DC); connect the light to FLASH and the antenna to the separate antenna input. WLT use according to its instructions. The output flashes and is not a source of continuous power. The original incandescent-lamp load limit is one or two warning lights, each rated 12 V / 21 W. Follow the terminal markings on the warning light and the board; do not apply the polarity of the auxiliary output here. Wiring diagram with ELDC. |
| S.C.A. – indicator | 24 V DC, maximum 4 W, voltage tolerance −30% / +50%. Function according to II/L4. The exact polarity of the pair is not marked here; with polarized accessories, check it on the specific board before connecting. |
| BLUEBUS | Power and communication for compatible devices. Photocells are connected with no polarity. Overall limit: 15 BlueBUS load units. For two Master/Slave motors the exact wire order must be observed. |
| STOP | Voltage-free NO, NC or 8.2 kΩ resistive devices; RUA1 learns the device type. A change in the learned state stops movement with a brief reverse movement. The contacts have no +/− polarity and must not be connected to an external voltage source. |
| P.P. / STEP-BY-STEP | Voltage-free NO contact for step-by-step operation. Connect the module relay's COM and NO contacts to the two P.P. terminals; the contact has no polarity. The module power supply is wired separately. |
| OPEN | Voltage-free NO contact for opening; no polarity. |
| CLOSE | Voltage-free NO contact for closing; when I/L7 is ON, it partially opens. No polarity. |
| AERIAL / antenna | Connect the coaxial cable's core and shield according to the markings on the receiver/board terminals. These are not power +/− terminals. RG58, 52 Ω input according to the instructions; choose an antenna to match the receiver frequency. |
Multiple devices on STOP
Connect NO contacts in parallel and NC contacts in series. Two 8.2 kΩ resistive devices can be connected in parallel; for more than two, use a configuration with a single 8.2 kΩ end-of-line resistor, as shown in the device diagram. A combination of NO and NC requires an 8.2 kΩ resistor in series with the NC branch. Do not replace a safety edge with a simple jumper. After making a change, repeat the learning procedure and safety test.
Fuses
Check only after disconnecting the mains supply. Replace fuses F1/F2 with the same type, time-delay characteristic and rating specified on the installed board. If a fuse blows repeatedly, identify the cause; do not install a higher-rated fuse.
RUA1 control unit wiring diagram
Wiring ELDC warning light, EPMB photocells and EKS key switch. Accessory shapes are for reference only; when wiring, follow the terminal markings on the specific device. For EKS, use C–NO for both OPEN and CLOSE; do not use the NC terminal shown in the drawing for a command.
| Accessories | Connection |
|---|---|
| ELDC – light | The two terminals of the input marked with a lamp symbol → the FLASH pair on RUA1. ELDC is designed for 12–36 V DC; do not connect it to 230 V mains. FLASH is not a continuous auxiliary power source. Follow the markings on the warning light and the board; do not apply the polarity of the STOP/P.P. auxiliary output here. |
| ELDC – antenna | Use a separate RG58 coaxial cable: connect the core to the antenna signal and the shield to the shield terminal according to the symbol. This is not a +/− power connection. Choose an antenna to match the frequency of the installed receiver. |
| EPMB – both TX and RX | The two BlueBUS terminals on each device → both BLUEBUS terminals on RUA1, in parallel and with no polarity. Do not confuse EPMB with EPM relay photocells. |
| EKS – opening / closing | C–NO on one microswitch → both OPEN terminals; C–NO on the other → both CLOSE terminals. Leave NC unconnected. These are two voltage-free contacts with no polarity; do not apply external voltage to the inputs. When I/L7 = ON, the CLOSE input triggers partial opening. |
Drive photocells
For the current setup, use compatible NICE EPMB. TX is the transmitter and RX is the receiver. Connect both devices to the two BLUEBUS terminals with no polarity; do not connect them to the auxiliary 24 V output. After adding or removing a device, repeat the device learning procedure and safety test. RUA1 has a limit of 15 BlueBUS load units; one unit does not necessarily equal one pair.
Wiring multiple EPMB pairs
Connect the pairs in parallel as shown in the diagram. TX and RX of one pair have the same address, the next pair must have a different address. Choose the mounting position, TX/RX orientation and wiring according to the safety direction and the gate’s hazardous areas.
Positioning the safety pairs
The positioning shown is for guidance only. FOTO and FOTO II protect the outer passage during closing, while FOTO 1 and FOTO 1 II protect the inner passage during closing; FOTO 2 and FOTO 2 II protect during opening. FOTO 3 is a single pair positioned along the gate leaf’s travel path, as shown in the diagram. Detection applies to its beam; it does not automatically cover all hazardous areas of the gate. When using FOTO II and FOTO 3 together, follow the TX/RX orientation in the photocell installation instructions to prevent interference between the pairs.
For standard safety wiring with RUA1, use addresses FOTO to FOTO 3. Do not use the FA1/FA2 settings for triggering opening in this configuration; do not interrupt connection A on the photocell.
EPMB photocell jumper table
Set the same combination on both the TX and RX of one pair. No two pairs in the same BlueBUS network may have the same address. Store any unused jumper in the designated dummy slot; do not leave it loose inside the photocell.
When replacing a photocell with the same type, retain the pair’s address and function. After replacement, check the TX/RX indicators and the gate’s safety response in both directions. If the type or number of devices changes, repeat the learning procedure.
Moving safety edge and FT210B
NICE FT210B transmits the status of an 8.2 kΩ resistive safety edge via an optical beam. The TX on the gate leaf is powered by its own battery; the RX is connected to polarity-free BlueBUS. Set the address and connect the safety edge according to the FT210B instructions; this is not a standard pair with a wire-powered TX. The RX current draw counts towards the BlueBUS load.
Radio receiver for gate operators
For a new setup, you can choose NICE OXIBD for the SM connector. For an existing SMXI or OXI, choose transmitters with coding supported by that receiver. Insert the receiver with the power disconnected; store transmitters according to the remote control pairing instructions and the instructions for the specific receiver. Radio memory, travel learning and RUA1 settings are separate functions.
![]() |
NICE Run RUN1800 gate operator is supplied with a NICE RUA1 control unit, which provides an SM connector for connecting an external radio receiver (e.g. NICE OXI, NICE SMXI). This receiver is essential for receiving commands transmitted from remote controls, so it is required for operating the sliding gate remotely by remote control. |
Selecting the gate’s direction of travel
The sliding gate’s direction of travel must be selected with regard to the position of the gate operator relative to the sliding gate leaf. View the gate from the side where the gate operator is installed.
![]() |
![]() |
| If the gate opens to the left, set the switch to the left. | If the gate opens to the right, set the switch to the right. |
The switch is on the right-hand side of the RUA1 control unit in the middle.
First power-up and device learning
Leave the gate leaf approximately halfway along its travel, engage the drive, check the direction setting and limit switches, and ensure the travel path is clear. Switch on the power. BLUEBUS should flash approximately once per second, and the LEDs on both TX and RX photocells should indicate operation. On the first start-up with factory settings, the FLASH warning light and S.C.A. indicator should be off. After commissioning, S.C.A. is controlled by the selected function II/L4; in the default mode, it is lit when the gate is open. If the status is incorrect, disconnect the power and fix the fault first.
- Press and hold OPEN + STOP/SET for approximately 3 s.
- Release when L1 and L2 start flashing rapidly.
- Wait for BlueBUS and the STOP input to be recognised. L1/L2 will stop indicating that learning is requested, and the STOP LED must be lit; L3/L4 may continue flashing because the travel path has not been learned.
- After adding or removing a device, repeat the learning procedure and retest its safety function.
Learning the travel distance
- After the device learning process is complete, press and hold CLOSE + STOP/SET for approximately 3 s.
- Release when movement begins. The first movement must be opening.
- If the gate closes, stop it using STOP, disconnect the power, correct the direction setting, and repeat the learning process.
- Allow the gate to open fully to the limit switch, then close fully to the second limit switch. Do not obstruct the gate’s path during learning.
- Check the correct end positions, partial opening, and several full cycles.
Testing and handing over the gate
Check movement in both directions, the mounting of the operator and rack, the limit and mechanical stops, and each safety device individually. Test the photocells during opening, closing, and while stationary, according to their function. Impact forces must be measured; repeat the test after changing the force, sensitivity, or soft start. Do not put the gate into service if any safety device is not working. The user must be given the keys and instructions, and shown how to release the gate manually and maintain it.
Programming the gate operator
The RUA1 board has OPEN, STOP/SET, and CLOSE buttons and eight LEDs, L1–L8. The gate must be stationary before making changes. After changing the safety settings, test the entire gate.
| Button | Normal operation / programming |
|---|---|
| OPEN ▲ | Opening / move to the next LED. |
| STOP/SET | Stop / enter settings and confirm. |
| CLOSE ▼ | Closing / move to the previous LED. |
Level I – switching functions on and off
- Press and hold STOP/SET until L1 starts flashing, approximately 3 s; release the button.
- Use OPEN/CLOSE to select the function’s LED.
- Briefly press SET to toggle ON/OFF. In programming mode, a short flash means OFF and a long flash means ON.
- Set the next function in the same way, or do not press any button for 10 s. The settings are saved and programming ends.
| LED – function and meaning | Status |
|---|---|
| L1 – Automatic closing After opening, the gate closes after the pause set by II/L1. The factory-set pause is 30 s. When OFF, the gate waits for a command. | OFF – factory setting ON – function enabled |
| L2 – Close after photocell After the passage is clear, the gate closes after 5 s. With I/L1 OFF, the gate opens fully first; with I/L1 ON, opening stops when the photocell beam is clear. A STOP command cancels this function for the current movement. | OFF – factory setting ON – function enabled |
| L3 – Always close After power is restored, the gate closes if open; the beacon flashes a warning for 5 s before movement. When OFF, the operator remains stationary after power is restored. | OFF – factory setting ON – function enabled |
| L4 – Slowdown At the end of opening and closing, the speed is reduced to approximately 60% of the rated speed. Available torque is halved; slowdown may not be suitable for a heavy gate or one with high resistance. | OFF – factory setting ON – function enabled |
| L5 – Boost When ON, the soft start is disabled and maximum starting force is used. This does not replace fixing friction, the track, or a frozen gate. After changing this setting, check that the forces are safe. | OFF – factory setting ON – function enabled |
| L6 – Pre-flashing The beacon gives a warning for 3 s before movement. When OFF, it starts flashing only when movement begins. | OFF – factory setting ON – function enabled |
| L7 – CLOSE = partial opening A CLOSE command from the terminals or remote control triggers partial opening according to II/L6. When OFF, it means closing. | OFF – factory setting ON – function enabled |
| L8 – Slave unit Enable this only on the second motor in a Master/Slave configuration. When OFF, the operator is the Master. | OFF – factory setting ON – function enabled |
Outside programming mode, the LED for each function is lit when ON and off when OFF. If L1/L2 or L3/L4 flash simultaneously, device or travel learning may be required; see LED diagnostics.
Level II – adjustable values
- Press and hold SET until L1 starts flashing, approximately 3 s; release.
- Use OPEN/CLOSE to select the parameter’s input LED.
- Press SET again and hold it while adjusting the setting. After approximately 3 s, the LED for the current value lights up.
- While continuing to hold SET, select the value using OPEN/CLOSE. Then release SET.
- Repeat the procedure for the next parameter; to exit, wait 10 s without pressing any buttons.
| Input LED – name and description | Setting LED – value |
|---|---|
| L1 – Pause duration Automatic closing time when I/L1 is enabled. | L1 – 5 s L2 – 15 s L3 – 30 s (factory setting) L4 – 45 s L5 – 60 s L6 – 80 s L7 – 120 s L8 – 180 s |
| L2 – Step-by-step mode Sequence of commands for P.P. and the corresponding radio channel. | L1 – Open → stop → close → stop L2 – Open → stop → close → open (factory setting) L3 – Open → close → open → close L4 – Shared entrance: while opening, another command is ignored; while closing, it reopens L5 – Shared entrance 2: same as L4; a command held for more than 2 s stops the gate L6 – Step-by-step 2: a brief command of up to 2 s triggers partial opening L7 – Hold-to-run: movement continues while the command is held L8 – Semi-automatic opening; closing while the command is held |
| L3 – Obstacle sensitivity Higher sensitivity responds to less resistance. First set the motor force at II/L5, then adjust sensitivity; measure the impact forces after making a change. | L1 – Very high – lightweight gates L2 – Very high L3 – High L4 – Medium L5 – Medium-low (factory setting) L6 – Low L7 – Very low L8 – Very low – heavy gates |
| L4 – S.C.A. output 24 V / max. output function 4 W. The radio channel selection also depends on the receiver. | L1 – Open gate indicator: off when closed, on when open; flashes slowly while opening and quickly while closing (factory setting) L2 – Active when the gate is closed L3 – Active when the gate is open L4 – Radio output 2 L5 – Radio output 3 L6 – Radio output 4 L7 – Maintenance indicator L8 – Electric lock |
| L5 – Motor force Torque control. Force is not determined by weight alone; do not use excessive force to overcome a mechanical fault. | L1 – 40% L2 – 50% L3 – 60% L4 – 80% L5 – 100% L6 – Semi-automatic 40–100% L7 – Semi-automatic 60–100% L8 – Automatic 0–100% (factory setting) |
| L6 – Partial opening Pedestrian opening distance. It must fit within the gate's actual travel distance. | L1 – 0.5 m L2 – 1.0 m (factory setting) L3 – 1.5 m L4 – 2.0 m L5 – 2.5 m L6 – 3.0 m L7 – 3.4 m L8 – 4.0 m |
| L7 – Maintenance alert Number of manoeuvres since servicing. Opening and closing are two manoeuvres; one complete cycle consists of opening and closing. | L1 – Automatic, based on movement difficulty (factory setting) L2 – 2,000 manoeuvres L3 – 4,000 manoeuvres L4 – 7,000 manoeuvres L5 – 10,000 manoeuvres L6 – 15,000 manoeuvres L7 – 20,000 manoeuvres L8 – 30,000 manoeuvres |
| L8 – Error log Records of the last eight manoeuvres; this is not an adjustable default setting. | L1 – Most recent manoeuvre L2 – Second most recent manoeuvre L3 – Third most recent manoeuvre L4 – Fourth most recent manoeuvre L5 – Fifth most recent manoeuvre L6 – Sixth most recent manoeuvre L7 – Seventh most recent manoeuvre L8 – Eighth most recent manoeuvre |
Two sliding gate leaves – Master/Slave
Each leaf has its own RUN and its own 230 V AC mains supply. One motor is the Master, the other the Slave. The number of motors does not increase the weight or length limit for an individual leaf.
BlueBUS connection
Maintain the wire order between the motors: terminal 1 Master → 1 Slave and 2 Master → 2 Slave as shown by the connectors oriented the same way in the diagram. Labels 1/2 indicate positions in the illustration, not universal power supply +/−. This is an exception to BlueBUS photocells, which do not require polarity.
Accessory shapes are indicative only. For OPEN and CLOSE on the EKS, use contacts C–NO; do not use the NC terminal shown in the drawing for the command. EPMB and the shared EKS key switch must be connected to the Master. Any second ELDC connect to FLASH on the second motor. The antenna is a separate coaxial connection.
- Set the opening directions for both opposing leaves and wire them according to the diagram with the power disconnected.
- Connect the receiver and shared safety/control devices to the Master.
- Switch on both motors. On the Slave, set level I, L8 = ON.
- Run device learning on the Slave first, then on the Master.
- Start travel distance learning on the Master and check that both leaves move together and that all safety devices work.
FLASH, S.C.A., a STOP safety edge and P.P. can be connected separately to the Slave. A P.P. command on the Slave opens only its own leaf fully; OPEN/CLOSE are not used on the Slave. Most settings are controlled by the Master. Sensitivity, force, S.C.A. output, Peak and error history are also assessed for the specific second drive.
Power supply for external accessories
The auxiliary output from the RUA1 is 24 V DC, −30% / +50%, maximum 100 mA total. At a nominal 24 V, this means approximately 16.8–36 V; the connected module must tolerate this range. The power supply and command contact are two separate pairs of wires.
| Purpose | RUA1 terminal | Accessory terminal |
|---|---|---|
| Power supply negative − | Right-hand STOP terminal in the orientation shown in the image below | − / GND device power supply |
| Power supply positive + | Left-hand P.P. terminal in the same orientation | + / V+ device power supply |
| Step-by-step command | Both P.P. terminals | Volt-free relay COM and NO; no polarity |
For higher current draw, an unsuitable voltage range or startup surges, use a separate power supply suitable for the module and connect only an isolated volt-free contact to P.P. Do not use the FLASH or BlueBUS output as a substitute for the auxiliary power supply.
Gate held open and timer
A volt-free P.P. command lasting longer than 2 s opens the gate and keeps it open for the duration of the command, for example when triggered by a timer switch. This function is not used in mode II/L2, setting L5 “Shared entrance 2”. If a continuous command is received unexpectedly, check the timer and the relevant input.
Emergency operation in the event of a safety device fault
Only under direct supervision and with the path completely clear and safe: if the first command is rejected due to a safety fault, issue the command again within 3 s and keep holding it. After approximately 2 s, the gate moves while you hold the command; releasing it stops the gate. This is a temporary emergency mode, not a substitute for repair. Never bypass a safety device for permanent operation.
Maintenance and servicing
Carry out maintenance at least every 6 months or after 20,000 manoeuvres, whichever comes first. Disconnect the power supply, check the fixings, corrosion, wear on the wheel and rack, the guide and free movement; clean the photocells and repeat the safety tests. The service indicator does not replace regular maintenance.
Maintenance reminder
The threshold is set by II/L7. To also have S.C.A. indicate maintenance, set II/L4 = L7.
| Counter status | FLASH / maintenance indicator |
|---|---|
| Below 80% of the threshold | FLASH flashes normally; the indicator lights for 2 s when opening begins. |
| 81–100% of the threshold | FLASH lights for 2 s at the start and then flashes normally; the indicator flashes during the cycle. |
| Above 100% of the threshold | FLASH lights for 2 s at both the start and end; the indicator flashes continuously. |
Checking the number of cycles
- Enter SET programming by holding for approximately 3 s; release when L1 flashes.
- Use OPEN/CLOSE to select input L7.
- Hold SET and wait approximately 3 s for the LED showing the current value to light up.
- While holding SET, briefly press OPEN + CLOSE simultaneously, then release them.
- The number of flashes from the value LED indicates how many tens of percent of the threshold have been used; no flashes means the value is below 10%. Release SET.
Resetting the service counter
- After completing maintenance, select II/L7 using the same procedure.
- Hold SET and wait approximately 3 s for the value LED to light up.
- While still holding SET, press OPEN + CLOSE for at least 5 s, then release both buttons.
- Rapid flashing confirms the reset; release SET and wait for programming to end.
This procedure resets the service counter. It does not erase transmitters, replace travel learning, or perform a full control unit reset. If there is an electronics fault, do not try an unverified button combination; follow the diagnostics and service procedures for the specific RUA1.
Troubleshooting
Before working inside an open operator, disconnect the power supply. Measurements on mains voltage or live terminals must be carried out by a qualified person. Contact our technical support with the motor model, board designation and number of flashes.
By fault symptom
| Symptom | What to check |
|---|---|
| Remote control does not light up | Check the battery and contacts in the remote control according to its instructions. |
| Remote control lights up, but the gate does not respond | Receiver compatibility and memory; pairing. Also test the button or P.P. input to distinguish a radio issue from an operator fault. |
| BLUEBUS is not lit | Check the mains supply and fuses with the power safely disconnected; do not bypass the safety device. |
| Command is not registered | When the BLUEBUS input changes, it flashes twice rapidly; an NO command from P.P./OPEN/CLOSE should light the corresponding LED. Check the contact and cable. |
| Gate starts moving, stops or reverses | First, manually check for friction, issues with the track or carriages, ice, rack clearance and end stops. Then check the force/sensitivity settings; changing them requires a new impact-force measurement. |
| Warning light does not work | Check FLASH, wiring, short circuits and compatibility of the warning light. During flashing, the measured voltage may fluctuate at approximately 10–30 V DC; this is not a constant 24 V supply. |
| S.C.A. does not work | First check mode II/L4, then the load (up to 4 W), cable and output (approximately 24 V DC). |
| Limit switch does not stop movement | Check the mounting and position of the electromechanical limit switch brackets. If the direction is incorrect, stop the operator and correct the direction selector. |
Warning-light diagnostics
During normal movement, the light flashes at regular intervals. An error code consists of a series of flashes, a 1 s pause, and the same series repeated; count the flashes in one series.
| Flashes | Meaning / solution |
|---|---|
| 1 | BlueBUS Check the devices, wiring and addresses. Repeat learning after repairs or a deliberate change to the setup, not to conceal a faulty safety device. |
| 2 | Photocell A normal response when the beam is interrupted in the protected direction. With the path clear, check cleanliness, alignment and addresses. |
| 3 | Resistance / obstacle detection Remove the obstacle and eliminate mechanical resistance. Do not increase Force or Peak without checking the gate and carrying out a subsequent safety test. |
| 4 | STOP The learned status has changed. Check the safety edge, contacts and wiring; do not bypass the safety device. |
| 5 | Internal parameters Wait 30 s and repeat the command. If the fault recurs, have the RUA1 serviced. |
| 6 | Cycle limit / temperature Wait a few minutes and let the motor cool down. Check the required operating frequency and mechanical resistance. |
| 7 | Electronic circuits Disconnect the power supply for a few seconds, then try again. If the problem persists, arrange servicing; do not guess at a reset procedure. |
| 8 | Continuous command Check the timer or for a control input that is continuously active. This may be expected if the gate is intentionally being held open. |
Control unit LEDs
BLUEBUS, STOP, P.P., OPEN, CLOSE
| LED / status | Meaning |
|---|---|
| BLUEBUS is not lit | No power or a fault. Check the mains supply and fuses. |
| BLUEBUS is continuously lit | Serious fault. Safely disconnect the power supply and check the wiring; if the fault recurs, arrange servicing. |
| BLUEBUS flashes once per second | Normal operation. |
| BLUEBUS flashes twice rapidly | Input status change or command received. |
| BLUEBUS series of flashes | Code as in warning-light diagnostics. |
| STOP is lit | Correct STOP state learned. |
| STOP is off | STOP state changed or learning is incomplete; check the safety devices. |
| P.P./OPEN/CLOSE is on | The corresponding volt-free contact is active. |
| P.P./OPEN/CLOSE is off | The corresponding contact is inactive. |
LEDs L1–L8
During normal operation, an illuminated LED indicates that a Level I function is enabled; an unlit LED indicates that it is disabled. L1 automatic closing, L2 close after photocell activation, L3 always close, L4 deceleration, L5 Peak, L6 pre-flashing, L7 CLOSE = partial opening, L8 Slave. A single flashing LED may indicate programming; L1/L2 together indicate device learning, and L3/L4 together indicate travel learning.
Reading the error history
- Press and hold SET for about 3 seconds, then release it when L1 flashes; use OPEN/CLOSE to select the L8 input.
- Hold SET; after about 3 seconds, the LEDs for the manoeuvres where an error was recorded will light up.
- While holding SET, use OPEN/CLOSE to select a specific record. L1 is the most recent record; L8 is the eighth most recent.
- Read the selected record's flash count using the beacon diagnostics. Release SET and wait for programming to finish.
Manual release of NICE RUN1800
Stop the gate, disconnect the power supply, and secure it against uncontrolled movement. Use the release mechanism only when the gate leaf is stationary.
| 1. Slide the release lock cover aside | 2. Insert the release key and turn it clockwise |
|---|---|
![]() |
![]() |
| 3. Pull out the release lever | 4. The gate can now be moved manually |
![]() |
![]() |
After moving the gate manually, close the release lever, lock the mechanism with the key, and replace the lock cover. Check that the gearbox has re-engaged before restoring the power supply. If the key is the only way to enter during a power outage, keep it accessible outside the enclosed property.
NICE RUN1800 technical specifications
Specifications apply to the 230 V AC version of the RUN1800. Rated specifications apply at approximately 20 °C. Always check the electrical version and permitted mains voltage range on the label of the specific motor as well.
| Parameter | Value |
|---|---|
| Model | RUN1800 – electromechanical limit switch |
| Type and control | Electromechanical sliding gate operator, RUA1; plug-in radio receiver not included with the standalone motor. |
| Motor and mains supply | 230 V AC, 50/60 Hz; tolerance as stated on the label of the supplied version. |
| Max. weight / length | 1,800 kg / 15 m; additional conditions and duty cycles as per the suitability tables. |
| Pinion | 18 teeth, module 4; rack tooth pitch approximately 12.6 mm. |
| Peak torque / force | 40 Nm / 1,110 N |
| Rated torque / force | 20 Nm / 560 N |
| No-load speed | 0.17 m/s at 50 Hz, approximately 10.2 m/min. |
| Rated speed | 0.14 m/s at 50 Hz, approximately 8.4 m/min. |
| Rated frequency for a 15 m gate leaf | 11 cycles/h, 264 cycles/day at rated torque; limits based on length, weight, and temperature also apply. This is not the number of cycles that can be run without a break. |
| Continuous operation | Maximum 40 minutes at rated torque, subject to additional duty-cycle limits. At 50 °C, maximum 10 minutes; for a 15 m gate leaf, maximum 7 cycles/h. |
| Power consumption / current | Starting: 700 W / 3 A; rated: 400 W / 1.8 A. |
| Electrical protection | Class I – PE protective earthing. |
| FLASH | For the current setup ELDC. Bulb load limit: one or two beacons, each 12 V / 21 W; this is not a continuous auxiliary power supply. |
| S.C.A. | 24 V DC, max. 4 W, voltage −30% / +50%. |
| Auxiliary power supply | 24 V DC, −30% / +50%, max. 100 mA total; observe the correct STOP/P.P. polarity. |
| BlueBUS | Max. 15 load units; photocells are polarity-independent. |
| STOP | Volt-free NO/NC or 8.2 kΩ resistor; learned state. |
| P.P., OPEN, CLOSE | Volt-free NO contacts. |
| Radio / antenna | SM connector; receiver selected separately. Antenna input specified in the original as 52 Ω; RG58 or similar coaxial cable. |
| Programming | 8 ON/OFF functions and 8 parameters; Levels I and II. |
| Learning | BlueBUS devices, STOP input type, and travel length with deceleration/partial-opening points. |
| Operating temperature | −20 to +50 °C |
| Ingress protection rating | IP44 |
| Unsuitable environments | Acidic, saline, or potentially explosive atmospheres. |
| Overall dimensions | 400 × 255 × 390 mm according to the technical table; installation dimensions are shown in the original drawing below. |
| Motor weight | 24.5 kg |
| Service life | Approximately 150,000–450,000 cycles, depending on the sum of the indices and the graph; not a guarantee. |
Operator dimensions
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]





































