The gate needs clear space throughout its entire swing arc, not just a wide enough opening between the posts. Before choosing the leaves, check the terrain, where the parked car will be, and the space needed for the operator. You’ll find the basic measuring information in the introductory guide.
| Swing gate: choose a topic | |
|---|---|
| Measuring and procedure | |
| Space and slope | Frame, hinges and infill |
| Operator and brackets | Stops and accessories |
Measure from the finished surface: allow for the future paving, post cladding and the position of the selected hinge axis.
How much space a gate leaf actually needs
Both leaves are the same length in every position. Allow extra space for the hardware, operator body and safe operation. Click to enlarge.
The leaf does not slide sideways. It pivots around the hinge axis, and its far corner traces an arc. With one long leaf, this arc is large, and the entire leaf is supported by one side of the entrance. With two leaves, the passage is divided between them, so each needs a shorter clear swing path. However, a double-leaf gate requires two operators if automated, two supporting posts and usually wiring to the operator on the opposite side. See the front view drawing and basic measurements.
Measure from the hinge axis, not from the edge of the post. The axis position depends on the hinge selected and how it is installed. A leaf hung from the inside edge of the post may provide a wider clear passage, but it needs different clearance around the post and may change the position of the operator bracket. If the hinge is moved, the swing-arc drawing and the motor mounting dimensions will no longer apply.
For an existing entrance, carry out a simple check:
- Mark the planned pivot axes of both leaves. Allow for the final post cladding and the thickness of the surface finish.
- Measure from each axis to the farthest corner in plan view of its respective leaf. Allow for hardware and overhangs; the swing radius is not half the clear distance between the posts.
- Mark the arc on the ground using a string, straightedge or tape measure. Check the entire intended opening angle. Check the wall, fence, steps, planters, downpipe and the space where the car will be parked.
- Pay particular attention to the space needed for the operator and its arm or housing. A clear path for the leaf does not necessarily mean there is room for the automation. Articulated-arm, linear and underground operators each have different space requirements.
Check the car in two positions: in front of the closed gate and behind the open gate. There may be enough space in the entrance for the swing arc itself, but the open leaves may intrude into the area where you need to manoeuvre the car after turning off the road. If the garage is close to the gate, also check the open doors of the parked vehicle.
Will there still be enough room for the car when the gate is open?
The opening between the posts and the usable passage width may not be the same. At the planned opening angle, check the projecting leaf, hinges and operator. Mark the car’s outline on the ground, including its mirrors, and check the approach from a turn as well. Assess a long van or trailer according to its actual path.
Example: a short driveway: the car stops in front of the garage after entering. Mark its outline and the swing arcs of the leaves on the ground. Check whether the gate can close behind the car and later open without hitting the bumper. If not, compare moving the gate, changing the division of the leaves, or using a folding or sliding system.
A common mistake: The plan shows 90° of clear space, so an operator is ordered automatically. Then there may be nowhere to anchor the bracket, or the motor may hit the leaf as it opens. First determine the hinge axis and required opening angle, then check the installation drawing for the exact operator.
Measure the driveway slope in both directions
On a slope, the deciding factor is the smallest clearance along the entire path, not just the gate’s closed position. Click to enlarge.
“Sloping driveway” can mean two different things. Crossfall runs from one post to the other. Longitudinal slope runs from the road into the yard. They often occur together, and their effect changes as the gate opens.
Crossfall
With a crossfall, you can design the bottom edge of the frame to follow the slope of the surface where the gate is closed. However, this only shows that the closed gate will not scrape the ground. As the leaf swings, its bottom edge passes over different points in the yard. With a double-leaf gate, the two leaves also start at different heights and must meet correctly at the central stop. What matters, then, is the minimum clearance throughout the entire swing path, not just the gap beneath the closed leaf.
Rising ground into the yard
When the ground rises from the road, a leaf on standard vertical hinges moves at essentially the same height while the terrain beneath it rises. Even a slight rise can stop the gate from opening after just a few dozen degrees. A more powerful motor will not solve this problem; it will only push the leaf into the obstruction.
A laser or hose level, tape measure and sketch are all you need to take measurements:
- Mark on the drawing the finished surface level along the axis of the closed gate. If the paving has not yet been laid, mark its final level. In that case, measuring the current soil level is only preliminary.
- Mark the swept area of each leaf. Measure the ground height by the post, roughly one-third of the way along the leaf and at its far edge, at several positions up to the planned opening angle. Take more detailed measurements around drains, raised paving stones and changes in slope.
- Compare the highest point you find with the bottom edge of the leaf in that position. If the frame is angled, checking just one corner is not enough: the entire bottom edge matters, as it projects onto a different part of the ground as it swings.
- Allow a reasonable operating clearance for the finished surface, water drainage, debris and winter conditions. There is no single standard figure for the clearance; it depends on the terrain, infill and stop.
If you cannot safely determine from the drawing whether the angled frame will meet the ground as it opens, it is cheaper to prepare a simple plan and elevation section or a movement model than to shorten a finished leaf after welding. With a significant crossfall and longitudinal slope, it makes sense to have the entire area surveyed.
Measurement example: paving rises into the yard
You measure 80 mm beneath the closed leaf. Where its bottom edge will pass, the finished paving is 100 mm higher. With a horizontal frame on vertical hinge axes, this will cause a collision: there is 20 mm of interference, even before allowing for operating clearance.
- Compare several points across the entire swept area in the same way. Use the planned finished paving level instead of the current ground level.
- First assess the gate position and any changes to the terrain. Then compare opening outward within your property, changing the division of the leaves, or choosing a different gate type.
- Check the final design again against the frame, stops and operator geometry. A more powerful motor or a standard support wheel will not give the leaf a clear path.
Related parts and guides: opening outward, folding systems, wheel requirements.
When opening inward is not feasible
If the gate opens outward, measure the space in front of it and the property boundary. Click to enlarge.
One possible solution is to change the gate position or the division of the leaves. Consider a larger gap beneath the frame only after checking the appearance, safety and bottom stop. If it would create an excessive gap, don’t solve the terrain issue simply by raising the entire gate.
Outward opening may help where the driveway rises steeply just beyond the gate. However, it requires space in front of the gate. Before planning, check the property boundary, space for pedestrians and vehicles, and the conditions for connecting to the road. The open gate leaf must not create an obstruction outside an area you have the right to use. If the gate is set farther back on the property, also check that there is room in front of it for a car to stop safely.
With automation, outward opening changes the position of the brackets, the direction of force applied by the operator, and the risk of collisions with the gate leaf. For Wingo and Toona linear operators, the usual solution is an extended rear bracket NICE PLA6. Check whether it is needed and where it should be positioned using the installation diagram for the selected model; the same solution does not automatically apply to articulated-arm or underground operators. See the check of the installation dimensions.
When a standard gate leaf gets in the way as it opens
Lifting gate leaf
Lifting gate leaf rotates and lifts simultaneously as it opens. It can clear rising terrain, but it changes the position of the entire gate leaf: the top edge may move closer to a wall or fence, the centre of gravity and the force needed to move it change, and the operator works differently than on a standard vertical axis. This solution requires the hinges, end positions and stops to be designed, and the suitability of the specific operator to be confirmed. It is not enough to buy an adjustable hinge and move its lower pin away from the upper one “according to a formula”.
Folding gate
As the gate opens, the outer panel folds towards the panel beside the post. Use the drawing for the selected mechanism for installation. Click to enlarge.
Folding gate can be useful when there is not enough depth for two standard gate leaves or enough space beside the fence for a sliding gate. The panels fold as they move, so they need a smaller continuous area in front of or behind the entrance. However, this adds more joints, a mechanism to coordinate the panels, and pinch points. Even with a folding design, check the slope, wind, clear passage and access for maintenance. A standard operator for one gate leaf is not automatically an approved configuration for a folding mechanism.
For a folding system, compare: the dimensions and weight of both panels, the position of the folding joint, the required opening angle and the space beside the post. Different systems are available for opening to approximately 90° and for folding farther back towards the fence. Check whether the specific kit requires a floor guide and which operator its manufacturer permits. The features of one kit do not apply to all folding gates.
If you want to compare this option for your entrance, see mechanisms for folding swing gates. For a double-leaf gate, you need a solution for both sides and an operator selected to suit the actual construction.
If you have enough length alongside the fence, also compare cantilever sliding gates and their components. On a steep slope where there is no room for a swing arc, a sliding gate may be a better choice, but it needs its own side track, supporting structure and foundation preparation. Choose the gate type to suit the space, not based on which operator has the biggest number on its product page.
Example: 4 m passage and a 1.5 m-high frame
Using an example opening of 4,000 mm and a 1,500 mm-high frame we’ll show how to check the space. Take the gate-leaf lengths from your drawing with the selected hinges; the illustrative passage width alone does not determine the frame dimensions.
Example situation: the gate leaves are to open inward to 90°, there is a low wall two metres away, and the paving rises from the road.
- Mark the arc of the entire gate leaf from the actual hinge axis. A space of approximately two metres does not by itself confirm that the frame, hardware and operator will fit.
- Measure the finished paving height across the entire swept area. Check the bottom edge of the frame, not just its far corner.
- If there is a collision, compare repositioning the gate, using a different division of the leaves, or opening outward. Only then assess a lifting or folding system.
Next, consider a single four-metre gate leaf. It would eliminate the central meeting point and the second operator, but would require a much larger clear area and place a significantly greater load on the single supporting post. For this type of entrance, it is therefore not automatically the simpler or cheaper option. Whether it is actually suitable depends on the design of the frame, post, hinges and specific operator.
Two gate leaves of different widths and a pedestrian entrance
If you often walk through, also consider a separate pedestrian gate. You won’t have to move a large gate leaf every time you pass through. Check its clear opening, opening direction and the space beside a parked car in your drawing.
A narrower leaf can provide a more convenient everyday passage, while a wider one clears the entrance for a car. Measure the usable width at the actual opening angle and the space needed for the wider leaf to swing. Assess its hinge, post and operator separately; the total passage width is not enough.
If the gate leaves overlap, determine which one opens first and closes last. For an automated gate, also check whether one leaf can be opened independently and how it is protected by the control system. Partial opening does not in itself guarantee safe passage for pedestrians.
For a small pedestrian gate built into a large gate leaf, you must ensure the operator is disabled when the pedestrian gate is open. Choose the safety devices and wiring for the specific system before manufacturing.
What needs to be clear before manufacturing
| What you have established on site | Why it matters |
|---|---|
| Finished distance between the posts and planned axis of each hinge | These determine the frame and the actual opening arc. |
| Opening direction and required opening angle | These determine the clear space, stops and operator installation geometry. |
| Surface heights across the full travel path of both gate leaves | These reveal collisions that are not visible when the gate is closed. |
| Positions of parked cars, pedestrians and fixed obstacles | The gate must work in normal use, not just during a test with no car present. |
| Type of infill and approximate weight of each gate leaf | These affect the posts, hinges, wind loading and choice of operator. |
| Space for the bracket, housing or arm of the selected operator | Without this, the specific automation cannot be confirmed. |
Once you have measured the site, check the following together: gate-leaf construction and space for the operator. Only then finalise the manufacturing drawing and building preparations. For a non-standard entrance, send a sketch and photos showing the hinge positions, dimensions and ground levels.
| Continue with what you need to resolve |
|---|
| Frame, hinges and infill · All situations and examples |