Frame, posts, hinges and infill for a swing gate

The frame, hinges and posts form a single unit. When designing a new gate, plan for the infill and the chosen operator from the outset: its brackets need a solid mounting point and the correct clearance from the hinge axis. The following recommendations will help you take measurements and select parts; the dimensions of load-bearing components must be determined for the specific gate leaf and mounting surface.

Swing gate: choose a topic
Measuring and procedure
Space and slope Frame, hinges and infill
Operator and brackets Stops and accessories
In this article
Frame and profiles Post and foundation
Choosing hinges Infill and wind
Stops and drop bolts Electric lock
Surface finish Manual test
Example: adding an operator later Example: new solid infill
Support wheel

Before cutting: determine the frame length based on the finished clear opening and the selected hinges. Mark the crossbar, infill attachment points and front operator bracket at its actual height.

Frame, crossbar and posts

The gate leaf transfers its own weight through the hinges to the post and foundation. Wind and the operator add further forces. When planning the gate, simply choosing a box section is not enough: the leaf length and height, frame rigidity, infill, hinge positions and bracket fixings all matter.

Box sections and frame crossbar

For a small leaf of around 2 m or less with lightweight, open infill, you could also consider a 40 × 20 × 2 mm box section. However, a 2 m length is not a verified load rating for this profile or a specification for the entire frame. When selecting from our structural profiles compare the cross-section, wall thickness and profile orientation in the frame. Give the frame manufacturer the leaf dimensions and weight, the infill fixing method and the operator bracket location.

Profiles in our range
Steel box section, 40 × 20 × 2 mm

40 × 20 × 2 mm box section

For lightweight, smaller structures; before using it for the perimeter frame, check the rigidity and load of the complete gate leaf.

Galvanised profile, 60 × 40 × 2 mm

Galvanised profile, 60 × 40 × 2 mm

Rectangular cross-section with a 2 mm wall. Mark on the drawing which way the wider side will face.

Galvanised profile, 80 × 40 × 2 mm

Galvanised profile, 80 × 40 × 2 mm

A deeper profile with the same wall thickness. Compare rigidity, frame weight and space for the hardware.

In the 4 × 1.5 m example, each leaf has one horizontal crossbar in the lower third. Before fitting it, check the spacing of the infill supports and the height of the front operator bracket. If the crossbar is also to support the operator, it must transfer its forces to the frame; do not choose its position based on appearance alone.

Gate-leaf frame with hinges on a common axis and a load-bearing mounting point for the front operator bracket.

The bracket position is determined by the operator installation drawing. The lower crossbar in this example is not a universal installation height. Click to enlarge.

Example: manual gate now, operator later

Clear opening 4 m, frame 1.5 m high and lightweight, open infill. You want to open the gate manually at first, then add operators once the yard is finished.

  1. Measure the finished opening and choose the hinges. Only after positioning them should you determine the width of both frames; a leaf approximately 2 m wide does not mean the cut length is 2 m.
  2. Compare the installation dimensions of the planned operator now. Prepare load-bearing mounting points for the brackets on both the post and the leaf, and a cable conduit under the driveway.
  3. For manual operation, choose stops, a way to hold the leaves open, and a drop bolt with its keeper. Before operating the motor later, the manual locking mechanism must be released or replaced with a suitable solution.

Related parts and procedures: profiles, hinges, drop bolt and keeper, conduit preparation.

Post and foundation

Post for a Wingo or Toona linear actuator: For a steel structure, we recommend allowing for a 120 × 120 mm post, or 100 × 100 mm if the specific geometry permits. The position of the hinge axis and bracket pin is determined by the operator installation drawing and geometry chart. With a different cross-section or position, a modified or extended PLA6 bracket, if the selected model allows it.

This is a recommendation for the available mounting space, not a structural minimum. Determine the wall thickness, anchoring and foundation based on the gate leaf, infill, wind and substrate. For HOPP with articulated arm check the available space against its own drawing.

Fix hinges and brackets to the load-bearing part of the post, not just to the cladding. For anchors, check the substrate type, anchoring depth and specified edge distances. For an existing masonry post, find out what is beneath the cladding. Foundation design requires information about the soil, water and local frost conditions; a single universal excavation size is therefore not enough.

It is practical to have conduit routes prepared before pouring the concrete. An underground operator requires construction preparation for the specific foundation box, including water drainage. Concrete curing time and anchor loading depend on the design and materials used.

Finish and infill installation

Before applying the finish, it is worth test-assembling the frame with the hardware and checking its geometry. Surface protection, coating repairs at welds, and drainage or vent holes depend on the chosen system. For hot-dip galvanising closed profiles, agree the required holes with the galvaniser before fabrication. The infill supplier will specify the recommended fixing method for the infill.

Back to article contents

How to choose hinges and their fixings

When replacing an existing hinge: Before removing it, take photos of the entire fixing and a close-up. Note the pin or thread diameter, hole spacing and distance of the axis from the post. The same thread with a different offset can change both the gap by the post and the operator geometry.

Choose the complete hinge assembly: hinge, pin or keeper, and fixings to both the post and the frame. An M16 or M20 thread alone does not determine the load capacity of the complete assembly.

What to compare What to check before ordering
Gate leaf Length from the hinge axis, total weight including infill, and spacing between the upper and lower hinges. The load capacity must apply to this combination.
Fixing Plate dimensions and holes for bolting; suitable load-bearing material for welding. The hinge must not be anchored only to the cladding.
Position and adjustment Clearance by the post, adjustment range and space for nuts. There must still be room for adjustment and locking after the surface finish is applied.
Keeper The exact pin size or a matching keeper recommended for the selected hinge. When replacing a hinge, send a photo of the complete pair.

An adjustable hinge helps fine-tune the gate-leaf position, but after adjustment it must be properly secured and the thread must have the specified engagement length. Do not add together two catalogue load ratings; check whether the manufacturer specifies the rating per item or for the assembly, and at what spacing.

Two aligned hinges, a vertical pivot axis and the hinge spacing on the gate-leaf frame.

The upper and lower pins must be exactly one above the other. Measure the spacing between the pin centres; a spirit level or laser makes it easy to check that they share an axis. Click to enlarge.

Type When to consider it What to check
Adjustable plate-mounted Screw-fix it to a suitable substrate. The plate, holes, anchors, adjustment range and drive clearance.
Adjustable weld-on A steel frame and load-bearing steel post. The weld, alignment, locknut and corrosion protection after welding.
Axial C-hinge A structure with a matching pin in the profile. The correct pin and profile, fitment and load-bearing requirements.
Special / offset A special geometry or a lifting gate leaf. The full travel path and explicit confirmation that it is compatible with the drive.
Related products
Adjustable screw-on hinge

Adjustable screw-on hinge

Measure the space for the plate and the hole spacing. Choose the thread size and anchors for the actual load-bearing substrate.

Adjustable weld-on hinge

Adjustable weld-on hinge

For a suitable steel structure. After adjustment, secure the thread and restore the surface protection.

CAIS H40 – axial C-hinge

CAIS H40 – axial C-hinge

Choose it together with the CAIS HP40 pin for welding into the profile. For the complete hinge system, also check the upper and lower bearings and the adjustment method.

A wider gate leaf puts a different load on the hinges than a narrower one of the same weight. If the product does not specify a value for your gate-leaf length and hinge spacing, have its suitability confirmed before ordering.

Browse the full range in the hinges for swing gates. The opening angle is affected by both the hinge and the geometry of the installed drive.

When to consider a support wheel

Choose a wheel only after checking the travel path. Check the route the wheel will follow across the ground, including joints, drainage channels and changes in slope. If it loses contact or catches on part of the curve, the load on the hinges and the resistance to movement will change.

A support wheel can be part of a planned gate-leaf support system. It needs a firm, unobstructed surface along the entire curve; gravel, a kerb or sunken paving can restrict its movement.

Measure height differences along the path and compare them with the wheel’s design. The spring travel is limited, and the wheel’s load capacity is not the permitted weight of the entire gate. For an automated gate, check that the support arrangement is permitted for the specific setup. If the gate leaf is already sagging, first fix the cause in the frame, hinges or post.

Back to article contents

Infill: appearance, weight and wind

The infill is an integral part of designing the frame and choosing the drive. The total weight of the gate leaf includes the frame, bracing, infill, fasteners and fittings.

Open infill, slats with gaps and a solid gate-leaf infill.

The more area the infill covers, the more wind loads the frame, hinges and drive. That is why the infill is one of the first factors to consider when sizing the other components. Click to enlarge.

Infill Things to consider when choosing
Aluminium slats The weight of the specific profile, support spacing, fastening, thermal expansion and isolation of dissimilar metals.
Galvanised board profiles The total weight and restoration of protection where cutting or welding has taken place.
Z-shaped slats The correct combination of slat and support system. The angle and overlap affect both visibility and airflow.
Wood, WPC and other infill materials Weight, expansion or moisture-related changes, required support and expansion gaps.
Related products
Aluminium slat 100 × 16 mm

Aluminium slat 100 × 16 mm

Check the required support spacing, fastening and expansion gaps in the infill instructions. Calculate the weight of the infill from the number and length of the slats.

Galvanised Z-shaped slat

Galvanised Z-shaped slat

Part of a system with an S-size support profile and an S1 layout; all components can be selected as a compatible set.

Solid infill in an exposed location

Wind loads the entire gate-leaf surface. If adding solid infill to a frame that was originally open, recheck the frame, hinges and posts, drive suitability and locking. For comparison, send the dimensions of each gate leaf, the infill type and a photo of the surrounding area. A more powerful motor or a lock alone will not fix an inadequate structure.

All gate and fence infill »

Example: you want to fit solid slats to an open frame

The gate opens easily now, but you want to reduce visibility from the street. The new infill will change both the weight and the area exposed to wind.

  1. Find the weight of the infill, including its support rails and fasteners. Use the lengths and number of slats to calculate the added weight for each gate leaf separately.
  2. Show the frame supplier how the infill is fastened, along with the frame’s cross-section and wall thickness, hinges and posts. Also check the required support and expansion allowance for the slats.
  3. For an existing drive, include its type and a photo of the open entrance. Reassess the choice for wind loads; a motor that was suitable before may not be suitable with the new infill.

Related parts and guides: comparing infill options, drive limits, electrical locking.

Back to article contents

Stops, drop bolts and locking

Plan the stop positions and locking method together with the frame. Allow a solid mounting point and enough operating clearance for a drop bolt or lock.

Plan the locking system before finishing the frame

For an automated gate, check in advance whether the drive requires an electric lock and the associated wiring. For overlapping gate leaves, determine the closing sequence. The manual drop bolt must not obstruct the drive when it starts.

Back to article contents

Test the gate by hand before installing the drive

  1. On a flat surface, check the frame dimensions, diagonals and flatness before completing the welds.
  2. Keep the hinge pins aligned on a common axis during installation. Test it with the planned infill, not just with a lightweight bare frame.
  3. Check the full arc of both gate leaves. Check the clearance from the paving, post and fence, as well as the stop positions.
  4. The gate leaf should move easily without catching or moving on its own. Then recheck the planned bracket dimensions and install the drive selected in advance.

If the gate leaf has to be lifted to open it by hand, a more powerful motor will not fix the mechanical fault. Fix the cause before automating the gate.

Send us the gate leaf dimensions, infill type, and a photo of the post, if you’re unsure about the hinge, stop, or clearance for the bracket.

Continue based on what you need to resolve
Drive unit, brackets, and preparation · All situations and examples